Uploaded by Abdullah Azam Khan

IP66 test report of ST03 and ST07

advertisement
Test Report
Page 1 of 10
Report No.: EED31I003638
Client
Address
: AGC Lighting Co., Ltd
: Building A, Jian’an Road No.3, Fuyong, Bao’an District, Shenzhen, China
Description of the submitted sample(s):
Sample Name
: LED Street Light
Model/Type
: See Model List
Trade
:
Ratings
Test Item
Surrounding
: See Model List
: IP66 test
: 23 ℃, 60%R.H.
State of Sample(s)
: Normal
Sample Quantity
Manufacturer
: 1 pc
: AGC Lighting Co., Ltd
Sample Received Date
Sample tested Date
Test Requested
: Jul. 08, 2016
: Jul. 12, 2016
: 1) EN 60598-1:2015;
2) According to client’s request.
: 1) The tested sample(s) and the sample information are provided by the client.
2) All models have the same construction of resistance to dust, solid objects
and moisture, the model ST07-120/K is selected to perform the tests.
Remark
Equipment list:
Test Equipment
Equipment Model
Equipment No.
Expiry Date of
Calibration
Dust Tester
KXT1410
TTE20151740
Oct. 15, 2016
Spray Nozzle Tester
IP-5/IP-6
BTTEELSZ20008
Mar. 08, 2018
Withstanding Voltage Tester
AN9602M
TTE20150431
Oct. 19, 2016
Temperature & Humidity meter
175H1
TTE20141686
Aug. 30, 2016
Stopwatch
TF807
BTTEELSZ10077
Aug. 27, 2016
Steel tape
5m
ATTEELSZ10027
Oct. 22, 2016
Test Results: Please refer to the next page.
Compiled by:
Reviewed by:
Approved by:
Date :
Amo Liu
Lab Supervisor
Centre Testing International Group Co., Ltd.
Aug. 01, 2016
Check No.: 2402634192
Hongwei Industrial Zone, Bao’an 70 District, Shenzhen, Guangdong, China
Test Report
Page 2 of 10
Report No.: EED31I003638
Model List
Model
Ratings
ST07-180
100-240V~, 50/60Hz, 180W
ST07-150
100-240V~, 50/60Hz,150W
ST07-120
100-240V~, 50/60Hz,120W
ST07-090
100-240V~, 50/60Hz, 90W
ST07-070
100-240V~, 50/60Hz, 70W
ST07-180/K
100-240V~, 50/60Hz,180W
ST07-150/K
100-240V~, 50/60Hz, 150W
ST07-120/K
100-240V~, 50/60Hz, 120W
ST07-090/K
100-240V~, 50/60Hz, 90W
ST07-070/K
100-240V~, 50/60Hz, 70W
ST03-150
100-240V~, 50/60Hz,150W
ST03-120
100-240V~, 50/60Hz,120W
ST03-090
100-240V~, 50/60Hz, 90W
ST03-070
100-240V~, 50/60Hz, 70W
ST03-050
100-240V~, 50/60Hz, 50W
ST03-030
100-240V~, 50/60Hz, 30W
ST03-150/K
100-240V~, 50/60Hz, 150W
ST03-120/K
100-240V~, 50/60Hz, 120W
ST03-090/K
100-240V~, 50/60Hz, 90W
ST03-070/K
100-240V~, 50/60Hz, 70W
ST03-050/K
100-240V~, 50/60Hz, 50W
ST03-030/K
100-240V~, 50/60Hz, 30W
Remark: The letter “K” of the models is expressed the luminaire has a photocontrol.
1. IP6X test
1.1 Test procedure
1) The luminaire is suspended outside the dust chamber and operated at rated supply voltage until operating
temperature is achieved.
2) The luminaire, whilst still operating, is placed with the minimum disturbance in the dust chamber. The
Test Report
Page 3 of 10
Report No.: EED31I003638
chamber shall contain 2 kg of powder for every cubic metre of its volume.
3) The fan or blower causing the talcum powder to be in suspension is switched on.
4) After 1 min, the luminaire is switched off and allowed to cool for 3 h whilst the talcum powder remains in
suspension.
1.2 Evaluation of test results
After completion of the tests, no deposit of talcum powder inside enclosure for dust-tight luminaire.
1.3 Test results:
Sample No.
Observations
Verdict
S160707003-2
No deposit of talcum powder inside enclosure for dust-tight luminaire.
Pass
2. IPX6 test
2.1 Test procedure
1) Normal operation at rated supply voltage until operating temperature is achieved.
2) The luminaire is switched off and immediately subjected to a water jet for 3 min from all directions by means
of a hose having a nozzle with the shade .The nozzle shall be held 3 m away form the sample.
3) The water pressure at the nozzle shall be adjusted to achieve a water flow rate of
100 L/min±5%(approximately 100 KN/m2).
2.2 Evaluation of test results
1) No trace of water on electrical connections, current carrying parts or on insulation where it could become a
hazard for the user or surroundings, for example where it could reduce the creepage distances below the values
specified in Section 11; the only exception to this is for SELV conductors where the voltage under load does
not exceed 12 V r.m.s. or 30 V ripple free d.c. and the conductors are protected from corrosion.
2) For luminaire without drain holes, where shall be no water entry.
3) After completion of the tests, test samples should withstand electric strength test.
2.3 Test results
Sample No.
Test time
S160707003-2
3min
Observations
Verdict
After the test, no water entered in the enclosure or
current-carrying parts.
Pass
2.4 Electric strength test results
Sample No.
Between
Test voltage
(V ac)
Test time
(min)
Observations
Verdict
S160707003-2
Input and metal
enclosure
1480
1
No flashover and
breakdown.
Pass
Test Report
Page 4 of 10
Report No.: EED31I003638
Photos of the sample
Fig.1- Overall view of model ST07-120/K
Fig.2- Overall view of model ST07-120/K
Test Report
Page 5 of 10
Report No.: EED31I003638
Fig.3- Sample during IP6X test of model ST07-120/K
Fig.4-Sample during IPX6 test of model ST07-120/K
Test Report
Page 6 of 10
Report No.: EED31I003638
Fig.5- Sample after IP6X test of model ST07-120/K
Fig.6- Sample after IP6X test of model ST07-120/K
Test Report
Page 7 of 10
Report No.: EED31I003638
Fig.7- Sample after IP6X test of model ST07-120/K
Fig.8- Sample after IP6X test of model ST07-120/K
Test Report
Page 8 of 10
Report No.: EED31I003638
Fig.9- Sample after IPX6 test of model ST07-120/K
Fig.10- Sample after IPX6 test of model ST07-120/K
Test Report
Page 9 of 10
Report No.: EED31I003638
Fig.11- Sample after IPX6 test of model ST07-120/K
Fig.12- Sample after IPX6 test of model ST07-120/K
Test Report
Page 10 of 10
Report No.: EED31I003638
Fig.13- Overall view of model ST03-150
Fig.14- Overall view of model ST07-180
*** End of Report ***
The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer
only to the sample(s) tested. Without written approval of CTI, this report can’t be reproduced except in full.