GE Security Kilsen Fire Systems Product Catalogue g In this catalogue you will find a wide range of Fire Protection equipment from GE Security. GE Security is a global technology leader dedicated to supporting the needs of the rapidly growing electronic security industry and to expanding current technologies, products and services that GE Security, unrivalled expertise in Fire Protection create revenue growth opportunities for its customers. As part of the GE family, GE Security shares the spirit of innovation that has distinguished GE for well over 100 years. GE Security's commitment to the ongoing success of its partners and affiliates means that we maintain a sharp focus on product and service innovation, world-class manufacturing practices and operational excellence. GE Security is a worldwide organisation with sales and technical support operations in 27 countries, and manufacturing and logistics operations in Europe, the U.S. and China. GE Security has expertise in all areas of electronic security, including: z Intrusion and Fire Protection z Electronic Access and Facility Management z Key Management and Remote Access Systems and Services z Fibre Optic Transmission and Reception Equipment z CCTV, Digital Video and Surveillance Equipment z Video Multiplexing and Digital Storage When you're looking for the finest in Fire Protection products with leading-edge technology and the backing of a world leader, you need look no further than this catalogue. Conventional Fire Systems Page : 3 NKB602 Conventional fire alarm panel with 2 zones The NKB600 Series microprocessor controlled, conventional fire panels incorporate state of the art technology, reliability, ease of installation and maintenance in a basic package. They are compatible with conventional detectors such as the Kilsen 200, 300, 500 and 700 series devices. The NKB602 has 2 conventional zones. Specifications Supply Voltage 125/230 VAC @ 50/60 Hz Mains fuse (Type 5x20 mm) 0.5/0.25 A Total consumption < 20 W Nominal Output Voltage 24 VDC Batteries Recommended batteries 2 off 1.9 Ah, 12 V Fuse Rating 1A Maximum load current < 100 mA Zone Maximum Load 72 mA Maximum number of detectors 20 Ouput voltage 22 to 28 VDC End-of-line resitance 4k7 Ohm Manual call point resistance 100 Ohm, 2 W Outputs Fire alarm 24 VDC ± 15%, 300 mA Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA Environmental Working temperature +5 to +40°C Storage temperature -10 to +70°C Relative humidity 95 % (non-condencing) Physical Characteristics Size (w x h x d) 305 x 295 x 100 mm Weight without batteries 3 kg Ordering Information NKB602 Conventional fire alarm panel with 2 zones E E E E E Modern, elegant design Compact models for 2, 4 and 6 zones Microprocessor controlled Multilingual keyboard 2 Access levels E Differentiation between alarms from manual call points and automatic detectors in the same zone E Acoustic indications for fire and fault E Optical indications for fire and fault by zone E Low maintenance E Compatible with all ranges of KILSEN conventional detectors Conventional Fire Systems Page : 4 NKB604 Conventional fire alarm panel with 4 zones The NKB600 Series microprocessor controlled, conventional fire panels incorporate state of the art technology, reliability, ease of installation and maintenance in a basic package. They are compatible with conventional detectors such as the Kilsen 200, 300, 500 and 700 series devices. The NKB604 has 4 conventional zones. Specifications Supply Voltage 125/230 VAC @ 50/60 Hz Mains fuse (Type 5x20 mm) 0.5/0.25 A Total consumption < 20 W Nominal Output Voltage 24 VDC Batteries Recommended batteries 2 off 1.9 Ah, 12 V Fuse Rating 1A Maximum load current < 100 mA Zone Maximum Load 72 mA Maximum number of detectors 20 Ouput voltage 22 to 28 VDC End-of-line resitance 4k7 Ohm Manual call point resistance 100 Ohm, 2 W Outputs Fire alarm 24 VDC ± 15%, 300 mA Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA Environmental Working temperature +5 to +40°C Storage temperature -10 to +70°C Relative humidity 95 % (non-condencing) Physical Characteristics Size (w x h x d) 305 x 295 x 100 mm Weight without batteries 3 kg Ordering Information NKB604 Conventional fire alarm panel with 4 zones E E E E E Modern, elegant design Compact models for 2, 4 and 6 zones Microprocessor controlled Multilingual keyboard 2 Access levels E Differentiation between alarms from manual call points and automatic detectors in the same zone E Acoustic indications for fire and fault E Optical indications for fire and fault by zone E Low maintenance E Compatible with all ranges of KILSEN conventional detectors Conventional Fire Systems Page : 5 NKB606 Conventional fire alarm panel with 6 zones The NKB600 Series microprocessor controlled, conventional fire panels incorporate state of the art technology, reliability, ease of installation and maintenance in a basic package. They are compatible with conventional detectors such as the Kilsen 200, 300, 500 and 700 series devices. The NKB606 has 6 conventional zones. Specifications Supply Voltage 125/230 VAC @ 50/60 Hz Mains fuse (Type 5x20 mm) 0.5/0.25 A Total consumption < 20 W Nominal Output Voltage 24 VDC Batteries Recommended batteries 2 off 1.9 Ah, 12 V Fuse Rating 1A Maximum load current < 100 mA Zone Maximum Load 72 mA Maximum number of detectors 20 Ouput voltage 22 to 28 VDC End-of-line resitance 4k7 Ohm Manual call point resistance 100 Ohm, 2 W Outputs Fire alarm 24 VDC ± 15%, 300 mA Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA Environmental Working temperature +5 to +40°C Storage temperature -10 to +70°C Relative humidity 95 % (non-condencing) Physical Characteristics Size (w x h x d) 305 x 295 x 100 mm Weight without batteries 3 kg Ordering Information NKB606 Conventional fire alarm panel with 6 zones E E E E E Modern, elegant design Compact models for 2, 4 and 6 zones Microprocessor controlled Multilingual keyboard 2 Access levels E Differentiation between alarms from manual call points and automatic detectors in the same zone E Acoustic indications for fire and fault E Optical indications for fire and fault by zone E Low maintenance E Compatible with all ranges of KILSEN conventional detectors Conventional Fire Systems Page : 6 NK702 Conventional fire panel with 2 fire alarm zones The NK700 series of conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. The NK704 has 4 conventional zones. Specifications Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz Batteries Capacity 2 x 2.3 Ah Fuse rating 2A Zone Maximum load 94 mA Max. number of detectors per 20 zone Maximum zone resistance 44 ohm Sounders Maximum load 250 mA Delay Selectable 0 - 9 min Relay outputs (excluding sounders) 1 A @ 30 VDC Extinguishing relay outputs Maximum load NA Fuse rating NA Auxilliary output 250 mA 24 VDC Resetable output Maximum load 100 mA Reset time 3s Environment Working temperature -5 °C to +40 °C Relative humidity 95 % (non condensing) IP rating IP30 Physical characteristics Size (mm) 297 (w) x 307 (h) x 105 (d) Weight (without batteries) 3.6 kg Ordering Information E E E E E E E E E E E E E Modern, attractive design Microprocessor-controlled From 2 up to 16-zones EN54 approved 2 User access levels 2 Monitored sounder outputs One-man test capability 24 Volt resetable output External 'Class Change' facility Alarm output with potential free relay Common fault output with potential free relay External watchdog Active end-of-line support E Addional optional modules with supervised or relay NK702 Conventional fire panel with 2 fire alarm zones outputs Conventional Fire Systems Page : 7 NK704 Conventional fire panel with 4 fire alarm zones The NK700 series of conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. The NK704 has 4 conventional zones. Specifications Supply voltage 230 VAC @ 50 Hz (±10%) Batteries Capacity 2 x 7.5 Ah Fuse rating 1A Zone Maximum load 72 mA Max number of detectors 20 Sounders Maximum load Relay outputs (excluding Sounders) 300 mA 2 A @ 250 V Extinguishing relay outputs Maximum load NA Fuse rating NA Open collector outputs 15 mA Auxilliary output Maximum load 300 mA 24 V resetable output Maximum load 150 mA Reset time 4 seconds Delays Sounder selectable 0.15 & 60 s Relay module 3 to 180 s Enviroment Working temperature +5°C to +40 °C Relative humidity 95 % (non-condensing) Ordering Information NK704 Conventional fire panel with 4 fire alarm zones E E E E E E E E E E E E E Modern, attractive design Microprocessor-controlled From 2 up to 16-zones EN54 approved 2 User access levels 2 Monitored sounder outputs One-man test capability 24 Volt resetable output External 'Class Change' facility Alarm output with potential free relay Common fault output with potential free relay External watchdog Active end-of-line support E Addional optional modules with supervised or relay outputs Conventional Fire Systems Page : 8 NK708 Conventional fire panel with 8 fire alarm zones The NK700 series of conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. The NK708 has 8 conventional zones. Specifications Supply voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz Batteries Capacity 2 x 7.5 Ah Fuse rating 5A Zone Maximum load 94 mA Max. number of detectors per 20 zone Maximum zone resistance 44 ohm Sounders Maximum load 250 mA Delay Selectable 0 - 9 min Relay outputs (excluding sounders) 1 A @ 30 VDC Extinguishing relay outputs Maximum load NA Fuse rating NA Auxilliary output 250 mA 24 VDC Resetable output Maximum load 100 mA Reset time 3s Environment Working temperature -5 °C to +40 °C Relative humidity 95 % (non condensing) IP rating IP30 Physical characteristics Size (mm) 420 (w) x 335 (h) x 110 (d) Weight (without batteries) 6.2 kg Ordering Information E E E E E E E E E E E E E Modern, attractive design Microprocessor-controlled From 2 up to 16-zones EN54 approved 2 User access levels 2 Monitored sounder outputs One-man test capability 24 Volt resetable output External 'Class Change' facility Alarm output with potential free relay Common fault output with potential free relay External watchdog Active end-of-line support E Addional optional modules with supervised or relay NK708 Conventional fire panel with 8 fire alarm zones outputs Conventional Fire Systems Page : 9 NK712 Conventional fire panel with 12 fire alarm zones The NK700 series of conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. The NK712 has 12 conventional zones. Specifications Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz Batteries Capacity 2 x 7.5 Ah Fuse rating 5A Zone Maximum load 94 mA Max. number of detectors per 20 zone Maximum zone resistance 44 ohm Sounders Maximum load 250 mA Delay Selectable 0 - 9 min Relay outputs (excluding sounders) 1 A @ 30 VDC Extinguishing relay outputs Maximum load NA Fuse rating NA Auxilliary output 250 mA 24 VDC Resetable output Maximum load 100 mA Reset time 3s Environment Working temperature -5 °C to +40 °C Relative humidity 95 % (non condensing) IP rating IP30 Physical characteristics Size (mm) 420 (w) x 335 (h) x 110 (d) Weight (without batteries) 6.2 kg Ordering Information E E E E E E E E E E E E E Modern, attractive design Microprocessor-controlled From 2 up to 16-zones EN54 approved 2 User access levels 2 Monitored sounder outputs One-man test capability 24 Volt resetable output External 'Class Change' facility Alarm output with potential free relay Common fault output with potential free relay External watchdog Active end-of-line support E Addional optional modules with supervised or relay NK712 Conventional fire panel with 12 fire alarm zones outputs Conventional Fire Systems Page : 10 NK716 Conventional fire panel with 16 fire alarm zones The NK700 series of conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. The NK716 has 16 conventional zones. Specifications Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz Batteries Capacity 2 x 7.5 Ah Fuse rating 5A Zone Maximum load 94 mA Max. number of detectors per 20 zone Maximum zone resistance 44 ohm Sounders Maximum load 250 mA Delay Selectable 0 - 9 min Relay outputs (excluding sounders) 1 A @ 30 VDC Extinguishing relay outputs Maximum load NA Fuse rating NA Auxilliary output 250 mA 24 VDC Resetable output Maximum load 100 mA Reset time 3s Environment Working temperature -5 °C to +40 °C Relative humidity 95 % (non condensing) IP rating IP30 Physical characteristics Size (mm) 420 (w) x 335 (h) x 110 (d) Weight (without batteries) 6.2 kg Ordering Information E E E E E E E E E E E E E Modern, attractive design Microprocessor-controlled From 2 up to 16-zones EN54 approved 2 User access levels 2 Monitored sounder outputs One-man test capability 24 Volt resetable output External 'Class Change' facility Alarm output with potential free relay Common fault output with potential free relay External watchdog Active end-of-line support E Addional optional modules with supervised or relay NK716 Conventional fire panel with 16 fire alarm zones outputs Conventional Fire Systems Page : 11 NK703 Conventional extinguishing control panel with 3 zones The NK703 conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. It has 1 double-knock extinguising area consisting of two fire zones, and 1 free fire detection zone. Specifications Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz Batteries Capacity 2 x 7 Ah Fuse rating 2A Zone Maximum load 94 mA Max. number of detectors per 20 zone Maximum zone resistance 44 ohm Sounders Maximum load 250 mA Delay Selectable 0 - 9 min Relay outputs (excluding sounders) 1 A @ 30 VDC Extinguishing relay outputs Maximum load 250 mA Fuse rating 0.3 A Auxilliary output 250 mA 24 VDC resetable ouput Maximum load 100 mA Reset time 3s Environment Working temperature -5 °C to +40 °C Relative humidity 95 % (non condensing) IP rating IP30 Physical characteristics Size (mm) 420 (w) x 335 (h) x 110 (d) Weight (without batteries) 6.2 kg Ordering Information NK703 Conventional extinguishing control panel with 3 zones E E E E E E E E E E E E E Modern, attractive design Microprocessor controlled 3 zone (1 ext. area) and 6 zone (2 ext. areas) available Automatic extinguishing agent release control 2 Access levels Supervised general sounder output Supervised extinguishing inputs and outputs One-man test capability 24 Volt resetable output External 'class change' facility Alarm output with potential free relay General fault output with potential free relay External watchdog Conventional Fire Systems Page : 12 NK706 Conventional extinguishing control panel with 6 zones The NK706 conventional fire alarm and extinguishing control panels is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, they are extremely simple to install and use due to their ergonomic, advanced design. It has 2 double-knock extinguising areas consisting of two fire zones each, and 2 free fire detection zones. Specifications Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz Batteries Capacity 2 x 7 Ah Fuse rating 2A Zone Maximum load 94 mA Max. number of detectors per 20 zone Maximum zone resistance 44 ohm Sounders Maximum load 250 mA Delay Selectable 0 - 9 min Relay outputs (excluding sounders) 1 A @ 30 VDC Extinguishing relay outputs Maximum load 250 mA Fuse rating 0.3 A Auxilliary output 250 mA 24 VDC resetable ouput Maximum load 100 mA Reset time 3s Environment Working temperature -5 °C to +40 °C Relative humidity 95 % (non condensing) IP rating IP30 Physical characteristics Size (mm) 420 (w) x 335 (h) x 110 (d) Weight (without batteries) 6.2 kg Ordering Information NK706 Conventional extinguishing control panel with 6 zones E E E E E E E E E E E E E Modern, attractive design Microprocessor controlled 3 zone (1 ext. area) and 6 zone (2 ext. areas) available Automatic extinguishing agent release control 2 Access levels Supervised general sounder output Supervised extinguishing inputs and outputs One-man test capability 24 Volt resetable output External 'class change' facility Alarm output with potential free relay General fault output with potential free relay External watchdog Conventional Fire Systems Page : 13 RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels The RB404 relay expander module provides 4 additional voltage free relays on the GE Security NK700/FP400/FEC400 conventional fire panels ranges. It allows for these relays to be allocated to individual detection zones, or for programming the activation of different relays depending on the status of one or more zones. Up to 4 of these modules may be used on every fire panel. Specifications Relay rating Voltage 250 VAC / 30 VDC Current 10 A Delay setting 0 to 9 minutes Ordering Information RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels E 4 Potential free relays E Up to 4 modules may be housed inside the fire panel cabinet E Programmable with basic boolen functions E Power supplied from fire panel bus E Output delay setting per relay Conventional Fire Systems Page : 14 SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels The SB404 expander module provides 4 additional supervised relays that provide 24 VDC outputs on the GE Security NK700/FP400/FEC400 conventional fire panels ranges. These relays may be configured to power sounders or as standard 24 VDC supervised outputs for other devices. Relays may be allocated to individual detection zones, or for programming the activation of different relays depending on the status of one or more zones. Up to 4 of these modules may be used on every fire panel. Specifications Auxiliary supply 24 VDC Relay Rating Voltage 250 VAC / 30 VDC Current 5A Delay setting 0 to 9 minutes Ordering Information SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels E 4 Supervised relays E Up to 4 modules may be housed inside the fire panel cabinet E Programmable with basic boolen functions E Output delay setting per relay E Configurable for sounder control or as supervised outputs Conventional Fire Systems Page : 15 EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels The EOL-ACT is designed for use with the NK700/FP400 fire panels from GE-Interlogix. It is an active end-of-line device to allow the monitoring of a conventional zone through a diode base (such as the KZ705D). Ordering Information EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels E Small E Easy to install Accessories Page : 16 KLBlack-S Black front panel cover (small footprint) The KLBeige-S is a beige coloured, front panel housing lid for the FP200/NKB600, FP402 and FP404/NK702 and NK704 series fire panels from GE Security. It allows the user to change the facure colour of the panel for colour matching or renewal in case of damage. Ordering Information KLBlack-S Black front panel cover (small footprint) E Customisation of panel colour scheme E Easy replacement KLBlack-B Black front panel cover (large footprint) The KLBlack-B is a black coloured, front panel housing lid for the FP408, FP412 and FP416/NK708, NK712 and NK716, the FEC400/NK703 and NK706, as well the FP1500/KSA701 series fire panels and repeaters from GE Security. It allows the user to change the facure colour of the panel for colour matching or renewal in case of damage. Ordering Information KLBlack-B Black front panel cover (large footprint) E Customisation of panel colour scheme E Easy replacement Addressable Fire Systems Page : 17 KSA701-1 Analogue addressable fire detection panel - 1 loop The KSA701 analogue addressable fire alarm control panel is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, it is extremely simple to install and use due to its ergonomic, advanced design. The panel is supplied in an elegant, high-quality, conveniently sized, heavy-duty enclosure. The cabinet allows for enough space for the batteries for the system to be housed inside the cabinet. The KSA701 is fully compatible with the Kilsen 700A series detectors and KAL400 series accessories. Specifications Supply voltage 110/230 VAC @ 50 Hz (+10% -15%) Current consumption (no devices connected) 175 mA Quiest. / 241 mA Alarm Batteries Capacity 2 x 12 V - 7 AH (SLA type) Fuse rating 3A Charger (Temp. comp. -3 V / °C) 350 mA @ 27.6 VDC @ 20 °C Loop characteristics per loop Capacity 250 addresses Maximum load 400 mA / 26 VDC to 32 VDC Maximum electrical characteristics 44 Ohm / 500 nF Sounders (reverse polarity supervision) Maximum load (2 Outputs) 250 mA each / 18 to 24 VDC Delays (adjustable in 10 s intervals) 10 to 600 seconds Relay outputs (potential free) 1 A @ 30 VDC 24 V Auxiliary output Maximum load 250 mA @ 18 VDC to 28 VDC Environment Working temperature -5°C to +40 °C Relative humidity (non-condensing) 0-95% IP rating IP30 Physical characteristics Size 420 mm (w) x 335 (h) x 110 (d) Weight (without batteries) 6.2 kg Ordering Information KSA701-1 Analogue addressable fire detection panel - 1 loop E E E E E E E E E E E E E 4 x 40 characters LCD display 20 Display zones EN54 compliant with approvals pending 2 User access levels 2 Monitored sounder outputs 2 Programmable voltage free relays 24 Volt auxiliary output I/O programming capabilities with Boolean functions Day/night sensitivity settings Coincidence within zones Upload/download and graphic PC software Panel networking Installation test capability Addressable Fire Systems Page : 18 KSA701-2 Analogue addressable fire detection panel - 2 loops The KSA701 analogue addressable fire alarm control panel is the ideal solution for small to medium-sized installations. Very powerful and cost-effective, it is extremely simple to install and use due to its ergonomic, advanced design. The panel is supplied in an elegant, high-quality, conveniently sized, heavy-duty enclosure. The cabinet allows for enough space for the batteries for the system to be housed inside the cabinet. The KSA701 is fully compatible with the Kilsen 700A series detectors and KAL400 series accessories. Specifications Supply voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%) Current consumption (no devices connected) 175 mA Quiescent / 241 mA in alarm Batteries Capacity 2 x 12 V - 7 AH (SLA type) Fuse rating 3A Charger rating (Temp. compensated -3 V / °C) 350 mA @ 27.6 VDC @ 20 °C Loop characteristics per loop Capacity 250 addresses Maximum load 400 mA / 26 VDC to 32 VDC Maximum electrical characteristics 44 Ohm / 500 nF approximately 2 km of 1.5 mm2 diameter cable Sounders (reverse polarity supervision) Maximum load 250 mA each (2 Sounder outputs available) / 18 VDC to 24 VDC Delays (software adjustable in 10 to 600 seconds 10 second intervals) Relay outputs (potential free) 1 A @ 30 VDC 24 V Auxiliary output Maximum load 250 mA @ 18 VDC to 28 VDC Environment Working temperature -5°C to +40 °C Relative humidity (non-condensing) 0-95% IP rating IP30 Physical Characteristics Size 420 mm (w) x 335 (h) x 110 (d) Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ah batteries Ordering Information KSA701-2 Analogue addressable fire detection panel - 2 loops E E E E E E E E E E E E E 4 x 40 characters LCD display 20 Display zones EN54 compliant with approvals pending 4 User access levels 2 Monitored sounder outputs 2 Programmable voltage free relays 24 Volt auxiliary output I/O programming capabilities with Boolean functions Day/night sensitivity settings Coincidence within zones Upload/download and graphic PC software Panel networking Installation test capability Addressable Fire Systems Page : 19 NC785 RS485 expansion kit for KSA701/FP1500 fire panels The NC785 RS485 expander allows for an easy upgrade to the KSA701/FP1500 series addressable fire panels. Each module adds an additional industry standard RS485 communication port to the panel. This port could be used for communications with other network nodes in the fire panel network. Specifications Number of ports 1 Communications medium RS485 Technical specifications Maximum cable length 1200 m Communication speed 9600 baud Cable CAT5 - twisted with screen Termination resistance 150 Ohm Ordering Information NC785 RS485 expansion kit for KSA701/FP1500 fire panels E Industry standard RS485 communications E No hardware configuration required Addressable Fire Systems Page : 20 KSA701R KSA701 Series LCD Repeater (mains powered) The KSA701R repeater allows the user to monitor and control panels connected to the KSA700 fire panel network via and RS485 link. It displays 20 zones in alarm and fault on the face of the panel, whilst all system messages are displayed on the easy to read, LCD display. Specifications Supply voltage AC version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%) DC version 24 VDC Current consumption 175 mA Quiescent / 200 mA in alarm Battery charger (AC version only) Capacity 2 x 12 V - 7 AH (SLA type) Fuse rating 3A Charger rating 350 mA @ 27.6 VDC @ 20 °C (Temperature compensated -3 V / °C) Environment Working temperature -5 °C to +40 °C Relative humidity 95% (non condensing) IP rating IP30 Physical characteristics Size 420 mm (w) x 335 (h) x 110 (d) Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ah batteries RS232 and RS485 standard Communication ports Ordering Information KSA701R KSA701 Series LCD Repeater (mains powered) E E E E E E E Modern, attractive design 4 x 40 characters LCD display 20 Display zones 3 User access levels 24 VDC or 230 VAC models available Panel networking Full system control Addressable Fire Systems Page : 21 KSA701R-24 KSA701 Series LCD Repeater (24VDC powered) The KSA701R repeater allows the user to monitor and control panels connected to the KSA700 fire panel network via an RS485 link. It displays 20 zones in alarm and fault on the face of the panel, whilst all system messages are displayed on the easy to read, LCD display. Specifications Supply voltage AC version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%) DC version 24 VDC Current consumption 175 mA Quiescent / 200 mA in alarm Battery charger (AC version only) Capacity 2 x 12 V - 7 AH (SLA type) Fuse rating 3A Charger rating 350 mA @ 27.6 VDC @ 20 °C (Temperature compensated -3 V / °C) Environment Working temperature -5 °C to +40 °C Relative humidity 95% (non condensing) IP rating IP30 Physical characteristics Size 420 mm (w) x 335 (h) x 110 (d) Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ah batteries RS232 and RS485 standard Communication ports Ordering Information KSA701R-24 KSA701 Series LCD Repeater (24VDC powered) E E E E E E E Modern, attractive design 4 x 40 characters LCD display 20 Display zones 3 User access levels 24 VDC or 230 VAC models available Panel networking Full system control Addressable Fire Systems Page : 22 KSA705 Analogue addressable fire panel (expandable to 5 loops) The KSA700 Series analogue addressable fire panels offer leading-edge technology for the control of analogue addressable fire detection devices. Their unique user-friendly programming facilitate the ideal control environment for either simple or complex fire systems. Specifications Supply voltage 230 VAC @ 50 Hz (+10% -15%) Current consumption (no devices connected) 175 mA Quiest. / 241 mA Alarm Batteries Capacity 2 x 12 V - 6 AH (SLA type) Fuse rating 4A Charger (Temp. comp. -3 V / °C) 350 mA @ 27.6 VDC @ 20 °C Loop characteristics per loop Capacity 250 addresses Maximum load 400 mA / 26 VDC to 32 VDC Maximum electrical characteristics 44 Ohm / 500 nF Sounders (reverse polarity supervision) Maximum load (2 Outputs) 250 mA each / 18 to 24 VDC Delays (adjustable in 10 s intervals) 10 to 600 seconds Relay outputs (potential free) 1 A @ 30 VDC 24 V Auxiliary output Maximum load 800 mA @ 18 to 28 VDC E E E E 4-line, 40-character LCD display Panel networking capability Graphic monitoring software Windows based up/download programming software E Remote programming and maintenance via modem and TCP/IP Environment Working temperature -5 °C to +40 °C Relative humidity 95% (non condensing) IP rating IP41 Physical characteristics Size 480 mm (w) x 455 (h) x 140 (d) Weight (without batteries) 13.6 kg Ordering Information KSA705 Analogue addressable fire panel (expandable to 5 loops) E E E E Repeater facilities Powerful auto-configuration functions Simple program options with on-screen menu selection EN54 compliant Addressable Fire Systems Page : 23 Analogue addressable fire panel with printer (expandable to 5 loops) KSA705P The KSA700 Series analogue addressable fire panels offer leading-edge technology for the control of analogue addressable fire detection devices. Their unique user-friendly programming facilitate the ideal control environment for either simple or complex fire systems. The KSA705P offers an additional internal printer facility. Specifications Supply voltage 230 VAC @ 50 Hz (+10% -15%) Current consumption (no devices 175 mA Quiescent / 241 mA in alarm connect) Batteries Capacity 2 x 12 V - 6 AH (SLA type) Fuse rating 4A Charger (Temp. comp. -3 V / 350 mA @ 27.6 VDC @ 20 °C °C) Loop characteristics per loop Capacity 250 addresses Maximum load 400 mA / 26 VDC to 32 VDC Maximum electrical characteristics 44 Ohm / 500 nF approximately 2 km of 1.5 mm2 diameter cable Sounders (reverse polarity supervision) Maximum load Delays (adjustable in 10 s intervals) Relay outputs (potential free) 250 mA each (2 Sounder outputs available) / 18 VDC to 24 VDC 10 to 600 seconds 1 A @ 30 VDC 24 V Auxiliary output Maximum load E E E E 4-line, 40-character LCD display Panel networking capability Graphic monitoring software Windows based up/download programming software E Remote programming and maintenance via modem and TCP/IP 800 mA @ 18 VDC to 28 VDC Environment Working temperature -5 °C to +40 °C Relative humidity 95% (non condensing) IP rating IP41 Physical characteristics Size 480 mm (w) x 455 (h) x 140 (d) Weight 13.6 kg without batteries / 21.6 kg with 2 x 7 Ah batteries Ordering Information KSA705P Analogue addressable fire panel with printer (expandable to 5 loops) E E E E Repeater facilities Powerful auto-configuration functions Simple program options with on-screen menu selection EN54 compliant Addressable Fire Systems Page : 24 KAL701 Loop driver module for KSA702/705 control panels The KAL701 1 loop expander allows for an easy upgrade to the KSA702 and KSA705 analalogue addressable fire panels. Each module consist of a simple plug in card and requires no additional settings or connections for full functionality. The KAL701 has loop isolators supplied on both drivers and allows full class-A loop functionality with up to 250 device addresses. Specifications Number of loops 1 Loop characteristics Capacity 250 addresses Maximum load 400 mA / 26 VDC to 32 VDC Maximum electrical characteristics 44 Ohm / 500 nF Maximum loop length 2 km Ordering Information KAL701 Loop driver module for KSA702/705 control panels E Expands the loop capabailities of the KSA702 and KSA705 E Allows for the connection of an additional 250 devices per unit E Two isolated drivers support full class-A operation E No hardware configuration required KAL732 RS232 communications module for KSA702/5 control panels The KAL732 RS232 expander allows for an easy upgrade to the KSA702 and KSA705 analalogue addressable fire panels. Each module adds an additional industry standard RS232 communication port to the panel. This port could be used for communications with a PC or for connections to a printer or modem. Specifications Number of ports 1 Communications medium RS232 Technical specifications Maximum cable length 15 m Communication speed 9600 baud Cable 3 core with screen Ordering Information KAL732 RS232 communications module for KSA702/5 control panels E Industry standard RS232 communications E No hardware configuration required Addressable Fire Systems Page : 25 KAL785 RS485 communications module for KSA702/5 control panels The KAL785 RS485 expander allows for an easy upgrade to the KSA702 and KSA705 analalogue addressable fire panels. Each module adds an additional industry standard RS485 communication port to the panel. This port could be used for communications with other network nodes in the fire panel network. Specifications Number of ports 1 Communications medium RS485 Technical specifications Maximum cable length 1200 m Communication speed 9600 baud Cable CAT5 - twisted with screen Termination resistance 150 Ohm Ordering Information KAL785 RS485 communications module for KSA702/5 control panels E Industry standard RS485 communications E No hardware configuration required KAL791 Protocol Converter RS232/485 - Kilsen / Johnsson Control The KAL791 is a protocol converter for the integration of Kilsen KSA700 analogue fire alarm systems into Johnsson Controls building management systems. It requires a 24 VDC supply from an auxiliary power supply source. Specifications Supply Voltage 24 VDC Current Consumption 260 mA Environment Working Temperature -5°C to +40 °C Relative Humidity (non-condensing) 0-95% IP Rating IP41 Physical Characteristics Size 390 mm (w) x 420 (h) x 135 (d) Weight 9.3 kg Ordering Information E RS232 or RS485 port options E Seemless integration with no additional programming on the fire system E 24 VDC Supply KAL791 Protocol Converter RS232/485 - Kilsen / Johnsson Control KAL732 RS232 communications module for KSA702/5 control panels KAL785 RS485 communications module for KSA702/5 control panels Addressable Fire Systems Page : 26 KSA1204 Analogue fire panel, 2 loops upgradable to 4, 64 display zones The KSA1204 allows for 2 addressble fire panel loops and 64 display zones. Specifications Supply voltage 230 VAC (+10/-15%) 50 Hz Supply current (max) 1.5 A Min. supply current @ 24 VDC 0.2 A Battery charger rating @ 27.6 VDC 1.6 A Total supply rating @ 27.6 VDC 2.5 A Relay rating @ 24 VDC 2A Weight (no batteries) 8 kg Dimensions (H x W x D) 440 x 444 x 125 mm Ordering Information KSA1204 Analogue fire panel, 2 loops upgradable to 4, 64 display zones LC1502 LON2000 NC2011 NC2051 NET1200 RB2016 2-loop extension board for 1200/2000 series fire panels LON700 driver for FP1200 / FP2000 ARCNET RS485 network card with single RS485 interface ARCNET network card with single optical interface board Dongle for 1200 series panel networking Relay extension board for 1200/2000 series fire panels MOD2000 Modem kit PCC2000 Programming and configuration software PCM2000 Maintenance and support software with copy protection key E E E E E E E E E E E E One man maintenance Maintenance warning Soak test On-line diagnostics and statistics Power supply for 72 hour autonomy Floating background compensation Coincidence within and in between zones Start-up default mode Upload/download configuration facilities with PC I/O programming including Boolean functions EN54 p2 & 4 and VDS approved 2 or 4 class A loops Addressable Fire Systems Page : 27 Addressable fire panel, 2-8 loops, 64-255 display zones upgradable KSA1208 A versatile, powerful addressable fire panel, 2 to 8 loops, 16 to 64 displayed zones with extensive I/O features. The fire panel can operate within a 31 panel network and can communicate with global repeaters and PC graphics. It supports all the 700 series LON devices and repeaters using a seperate two wire bus. It is truly user-friendly and provides a generous 8 x 40 backlit graphic display. I/O control is done via powerful boolean I/O programing. Extensive maintenance features are provided standard. The KSA1200 series supports 1500 series sensors and 400 series I/O units. Specifications Supply voltage 1 190 - 270 V ac Supply voltage 2 40 - 60 Hz 160 VA max. 21 - 27 V dc Current consumption Quiescent @ 24 V dc (equipped loop) 800 mA Alarm current @ 24 V dc 1A Available auxiliary current in alarm 3A Battery charger rating @ 27.5 V dc 3A Total supply rating @ 27.5 V dc 4A Relay rating @ 24 V dc 2A Weight (no batteries) 15 kg Dimensions (mm) (H x W x D) 804 x 441 x 109 Ordering Information KSA1208 Addressable fire panel, 2-8 loops, 64-255 display zones upgradable E E E E E E E E E E E E One man maintenance Graphic maintenance Maintenance warning Service reminder signal Soak test On-line diagnostics and statistics Floating background compensation Day/night sensitivity setting Coincidence within and in between zones Automatic timed and manual on/off zones Start-up default mode Service switch E Upload/download, remote maintenance and graphic PC software E E E E E E I/O programming including Boolean functions ARCNET panel networking EN54 approved; certified Bosec, VdS, NFA2P Networkable "black box" and "global zone" system Full range of repeater panels Full range of LON devices Addressable Fire Systems Page : 28 KSA1264R Repeater / emulator with 64 zone indications A repeater / emulator with 64 displayed fire and fault zones, used in KSA1200 networked systems. The repeater is connected on the arcnet network and can operate in a local or global repeater mode. An 80 x 40 backlit graphic display and full indication and control keyboard is provided standard. Specifications Supply voltage 230 Vdc Current consumption 300 mA max Weight 15 kg Dimensions (mm) (H x W x D) 804 x 441 x 109 Ordering Information KSA1264R Repeater / emulator with 64 zone indications E 8 x 40 character graphic display E Arcnet network connection to KSA1200 series fire panels E E E E E Global repeater function Comprehensive control and display functions Emulation function 64 zones fire and fault displayed 230 VAC operation Addressable Fire Systems Page : 29 KSA12255R Global zone repeater, 64 zones expandable up to 255 A repeater/emulator with 64 fire and fault zones, expandable to 255, used in 1200/2000 series networked systems. The repeater is connected on the arcnet network and can operate in a local or global repeater mode. An 80 x 40 character, backlit graphic display and full indication and control keyboard is provided standard. Specifications Supply voltage 1 190 - 270 VAC 40- 60 Hz 160 VA max. Current consumption Quiescent 800 mA Alarm current @ 24 V dc 1A Available auxiliary current in 3 A alarm Battery charger rating @ 27.5 3 A V dc Total supply rating 4A Weight (no batteries) 15 kg Dimensions (mm H x W x D) 804 x 441 x 109 Ordering Information KSA12255R Global zone repeater, 64 zones expandable up to 255 LON2000 NE2011 NE2051 ZE2064 LON700 driver for FP1200 / FP2000 RS485 network extension board Fibre optic network extension board 64-zone LED extension fire and fault LED E On-line diagnostics and statistics E Upload/download, remote maintenance and graphic PC software E I/O programming including Boolean functions E ARCNET panel networking E Full range of 700 series LON devices Addressable Fire Systems Page : 30 LC1502 2-loop extension board for 1200/2000 series fire panels The LC1502 is a 2-loop extension board for 1200/2000 series fire panels. It allows for 2 additional class-A loops to be inserted into the fire panel, and supports up to 250 addressable loop devices per loop. Specifications Current consumption Quiescent @ 24 VDC (Fully equipped loop) + 150 mA (252 detectors) Ordering Information LC1502 2-loop extension board for 1200/2000 series fire panels E E E E LON700 driver for FP1200 / FP2000 FP1200 / FP2000 series A LON700 driver that connects FP1200 / FP2000 fire panels to LON700 devices Ordering Information LON2000 LON700 driver for FP1200 / FP2000 2 Class-A loops Up to 250 devices per loop (protocol dependent) Supports various detector protocols No hardware address required LON2000 Addressable Fire Systems Page : 31 LON driver for FP1200/2000 - closed loop systems LON2000R The LON2000R is a LON700 driver that connects 1200/2000 series fire panels to LON700 series devices on a closed loop, CLASS-A LON700 network. Ordering Information LON2000R LON driver for FP1200/2000 - closed loop systems ARCNET RS485 network card with single RS485 interface The NC2011 is an interface board to connect an RS485 copper network directly into the 1200/2000 series fire panels. It is supplied with one NE2011 pre installed. Ordering Information NC2011 ARCNET RS485 network card with single RS485 interface NE2011 RS485 network extension board NC2011 Addressable Fire Systems Page : 32 ARCNET network card with single optical interface board NC2051 The NC2051 is an interface board to connect a fiber optic network directly into the 1200/2000 series fire panels. It is supplied with one NE2051 pre installed. Ordering Information NC2051 ARCNET network card with single optical interface board NE2051 Fibre optic network extension board RS485 network extension board The NE2011 is a RS485 network extension board for the NC2011 to allow dual bus and closed ring networks. Ordering Information NE2011 RS485 network extension board NE2011 Addressable Fire Systems Page : 33 Fibre optic network extension board NE2051 FP1200 / FP2000 series An extension board for the NC2051 to allow a fibre optic ring bus Ordering Information NE2051 Fibre optic network extension board Internal printer The PR2000 is a panel mount, 40-column dot matrix printer to be used with the 1200/2000 series fire panels. It is supplied with all necessary accesories to allow easy installation into cabinets that allow for this option. Ordering Information PR2000 Internal printer PR2000 Addressable Fire Systems Page : 34 RB2016 Relay extension board for 1200/2000 series fire panels The RB2016 is an extension board for 1200/2000 series fire panels. It allows for up to 18 additional potential free relays to be added into the fire panel cabinet. Depending on the size and hardware configuration of the panel, up to 4 RB2016s may be included in any panel. Specifications Relay Contact Rating 1 A @ 30 VDC / 0.3 A @ 110 VDC / 0.3 A @ 125 VAC Ordering Information RB2016 Relay extension board for 1200/2000 series fire panels E Up to 18 potential free relay outputs E No hardware address required 64-zone LED extension fire and fault LED The ZE2064 allows the extension of the zones of the Fx2x128 and Fx2x255 fire panels and repeaters by 64 additional zones. Ordering Information ZE2064 64-zone LED extension fire and fault LED ZE2064 LON700 Devices Page : 35 FRL700 LCD repeater The LON700 LCD repeater is a smart and compact, cost-effective solution for fire panel repeaters. It is also available as an FBP700 fire brigade panel for Dutch and Scandinavian norms. Specifications Dimensions (l x w x d) 240 x 320 x 60 mm Weight 1.5 kg Operating temp °C -5°C to +40°C Operating voltage 15 - 30 VDC Current consumption Max. quiesent 100 mA Bus Connection two wire LON700 Bus Cable CAT 5 Total number of repeaters 700/1200/2000 Series 15 Ordering Information FRL700 LCD repeater E E E E E 2 wire connection between fire panel and repeaters Up to 1500 metre bus length 24 Volt power supply Cost effective repeater solutions Easily installed, simple operation E 4 x 20 charater LCD display, common LED's, push button control E LON700 module LON700 Devices Page : 36 LON700 network amplifier (4 way) NA704 The NA704 is an interface board to allow an extension of the LON700 network above its normal limitations. It acts as a network amplifier allowing for reconstruction and re-transmission of the LON700 signal, as well as allowing for T-offs of the network as required. Ordering Information NA704 LON700 network amplifier (4 way) NE771 LON700 driver for the NC771 and NA704 NE2051 Fibre optic network extension board LON700 interface board The NC700 is an interface board to connect a LON700 bus from a fire panel to a FB7xx 'black box'. Ordering Information NC700 LON700 interface board NC700 LON700 Devices Page : 37 LON700 closed loop communication board (no driver) NC771 The NC771 is an interface board to connect a LON bus from a fire panel to a FB7xx 'black box' panel. It allows for full Class-A type LON700 networks. Ordering Information NC771 LON700 closed loop communication board (no driver) NE771 LON700 driver for the NC771 and NA704 NE2051 Fibre optic network extension board LON700 driver for the NC771 and NA704 The NE771 is a LON700 network extension board to allow dual bus and closed ring networks on the NC771 and the NA771. Ordering Information NE771 LON700 driver for the NC771 and NA704 NE771 LON700 Devices Page : 38 LON700 output board with 24 open collector outputs OCB724 The OCB724 is a 24 way open collector board used in a LON700 system. Ordering Information OCB724 LON700 output board with 24 open collector outputs Plug-in power supply 3.5 A The PS700 power supply can be used to extend the power output in LON700 systems. Ordering Information PS700 Plug-in power supply 3.5 A PS700 LON700 Devices Page : 39 LON700 output board with 8 relays RB708 The RB708 is an eight way relay board used in LON700 systems. Specifications Number of outputs 8 Relay contact rating Switching current 2A Switching volage 42V ac/dc Switching power 60W Ordering Information RB708 LON700 output board with 8 relays Supervised input board 16 way LON700 The SIB716 is a sixteen way input board used in LON700 systems. Ordering Information SIB716 Supervised input board 16 way LON700 SIB716 LON700 Devices Page : 40 LON700 output board with 8 supervised outputs SOB708 The SOB708 provides eight supervised outputs that can be used in LON700 systems. Specifications Number of outputs 8 Output type polarity reversal End of line resistor 5.6 Kohm Output current per output 500mA Total current for all outputs 2A Open circuit >27 Kohm Normal 1.2 - 18 Kohm Short circuit < 470 ohm Ordering Information SOB708 LON700 output board with 8 supervised outputs 8 zone input extension board The ZI708 is an eight zone input expansion board for LON700 compatible systems. It allows for the connection of up to 8 conventional fire detector zones and is compatible with most industry standard conventional detectors. Ordering Information ZI708 8 zone input extension board ZI708 Gas Detection Page : 41 KM260/1R3-03 CO detection control panel - 1 Zone (English Version) The KM-Series CO detection system is designed for applications such as vehicle parking areas where concentrations of CO may accumulate. The range is compliant with the UNE23.300/84 standard. The KM260/1 is a 1 (upgradable to 2) zone control unit, using KM170 detectors. Specifications Power supply Mains supply 230 VAC ±10% 50 Hz Power consumption 95 W (max) Zone configuration Zone input voltage 10-20 VDC/VAC Sensitiviy 0-300 ppm Cable requirement 3 core 1.5 mm² Cable length (max) 350 m No. of detectors (max) 15 No. of zones (max) 2 Mechanical Housing (w x h x d) 275 x 335 x 130 mm Weight 6 kg Ordering Information KM260/1R3-03 CO detection control panel - 1 Zone (English Version) E E E E E E E E E E E E E E E E Designed according to norm 23300/84 Miner CDM8001 and CDM8002 standard password LGAI 154.909 and 96013132 standard certification Easy to use Low current consumption Direct reading of measured levels Easy installation Extraction relays and alarm outputs per area From 1 to 5 areas 3-wire system Modular design Up to 15 detectors per zone 10 seconds response time Elegant design Supervision of all zone lines Available in various languages Gas Detection Page : 42 KM260/3R3-03 CO detection control panel - 3 Zones (English Version) The KM-Series CO detection system is designed for applications such as vehicle parking areas where concentrations of CO may accumulate. The range is compliant with the UNE23.300/84 standard. The KM260/3 is a 3 (upgradable to 5) zone control unit, using KM170 detectors. Specifications Power supply Mains supply 230 VAC ±10% 50 Hz Power consumption 95 W (max) Zone configuration Zone input voltage 10-20 VDC/VAC Sensitiviy 0-300 ppm Cable requirement 3 core 1.5 mm² Cable length (max) 350 m No. of detectors (max) 15 No. of zones (max) 5 Mechanical Housing (w x h x d) 470 x 335 x 130 mm Weight 10.2 kg Ordering Information KM260/3R3-03 CO detection control panel - 3 Zones (English Version) E E E E E E E E E E E E E E E E Designed according to norm 23300/84 Miner CDM8001 and CDM8002 standard password LGAI 154.909 and 96013132 standard certification Easy to use Low current consumption Direct reading of measured levels Easy installation Extraction relays and alarm outputs per area From 1 to 5 areas 3-wire system Modular design Up to 15 detectors per zone 10 seconds response time Elegant design Supervision of all zone lines Available in various languages Gas Detection Page : 43 KM260EXT3-03 CO detection expansion module (English Version) The KM260 is an expansion module for the KM260-Series CO panels from GE-Interlogix. It allows for an additional monitoring zone to be added to the control panel, each module allowing for an additional 15 sensors to be connected. Specifications Power supply Mains supply 230 VAC ±10% 50 Hz Power consumption 95 W (max) Zone configuration Zone input voltage 10-20 VDC/VAC Sensitiviy 0-300 ppm Cable requirement 3 core 1.5 mm² Cable length (max) 350 m No. of detectors (max) 15 No. of zones (max) 1 Ordering Information KM260EXT3-03 CO detection expansion module (English Version) E E E E E E E E E E E E E Designed according to norm 23300/84 Miner CDM8001 and CDM8002 standard password LGAI 154.909 and 96013132 standard certification Easy to use Low current consumption Direct reading of measured levels Easy installation Extraction relays and alarm outputs per area 3-wire system Up to 15 detectors per zone 10 seconds response time Supervision of zone line Available in various languages Gas Detection Page : 44 Blanking plate for KM260 panels The blanking plate is used on KM260 panels during upgrading of modules to cover up any unused positions that may exist on the panel. Ordering Information KM260C Blanking plate for KM260 panels KM260C Gas Detection Page : 45 KM170 CO detector with base and mounting supplement The KM170 detector is specifically designed to react to the presence of carbon monoxide. The design complies with the requirements of the UNE 23-300 standard. Specifications Sensor type TGS semicondictor Useful life 4 years Electrical characteristics Supply voltage 10 to 20 VDC Quiescent current 35 mA Reaction time 10 s Environmental Operating temperature 0 °C to +40 °C Protection index IP205 Mechanical Size (h x Ø) 81 x 109 mm Weight 115 g Material and colour ABS white Installation Number of detectors per zone 15 Covarage 300 m² Ordering Information KM170 CO detector with base and mounting supplement E Complies with the requirements of the UNE23-300 standard E E E E Microprocessor based Resolution of up to 5 ppm Response time of 10 s Low current consumption E Local status indication of: -Normal operation -50ppm detected -Fault E Useful life of up to 4 years Gas Detection Page : 46 KZ400 Detector base for KL400/KM170 series devices The KZ400 base is designed to be used with the KL400 series detectors, but may also be used as a substitution base for KM170 CO detectors. Specifications Dimensions Diameter 107 mm Height 22 mm Ordering Information KZ400 Detector base for KL400/KM170 series devices E Polarity sensitive E Remote indicator contact available S300 Surface mount supplement for KL300/KM170 detectors The S300 is a base accessory designed for use with the KZ300 and KZ400 detector base. It allows for a surface mount conduit and cable to enter the base from the side. The KZ300 and KZ400 base fits on top of this accessory. The S300 can also be used with KM170 CO detectors. Specifications Dimensions Diameter 107 mm Height 25 mm Ordering Information S300 Surface mount supplement for KL300/KM170 detectors E Surface mount accessory for KZ300 E May be used with KM170 CO Detectors Aspiration Systems Page : 47 ASD20C Aspiration Smoke Detector The ASD20 Aspiration Smoke Detector consists of an analysis chamber with one or two smoke detectors, connected to standard 25 mm Ø PVC piping. The detectors can be of conventional or analogue technology, ionisation or optical. Specifications Power supply voltage 24 VDC Current Consumption Standby 250 mA 1st alarm 280 mA 2nd alarm 320 mA Fault 220 mA Environmental Characteristics Working temperature -10 to +60°C Storage temperature -10 to +70°C Relative humidity <95% Physical Characteristics Size 314 x 254 x 115 Weight 4 kg Colour RAL9999 Material Polycarbonate Cable input 3 x PG11 Wire cross-section Max. 1.5 mm² Coverage area per intake 30 m² Maximum num. of intakes 12 DIN 8062-type PVC pipes Ø25 mm Useful lifetime of motor 65 000 hours at 40°C Ordering Information ASD20C Aspiration Smoke Detector ASD20F Filter housing for ASD20 ASD20FIL Filter only for ASD20 E Used with conventional or analogue detectors E Direct connection to an analogue loop or stand-alone operation E E E E E Alarm 1, alarm 2 and fault relay outputs 24 VDC power supply Simple and robust architecture 30 m² coverage per sample intake Standard 25 mm PVC piping system E Installation of piping in I-shape and U-shape (symmetrical or assymmetrical) E Continuous supervision of pipe flow volume Aspiration Systems Page : 48 ASD20F Filter housing for ASD20 The ASD20F is an aluminium filter housing for the ASD20 aspiration detection system. It houses and protects the the air filter, the ASD20FIL, that has to be ordered seperately. Ordering Information ASD20F Filter housing for ASD20 ASD20FIL Filter only for ASD20 E Robust, light weight, aluminium construction E Easy to install E Easy filter replacement Filter only for ASD20 Filter only for ASD20 Aspiration Detector. Ordering Information ASD20FIL Filter only for ASD20 ASD20FIL Conventional Fire Systems Page : 49 KV210 Rate-of-Rise Heat Detector The KV210 heat detectors are designed to activate when the temperature exceeds a preset level or when the speed at which the temperature changes is above a set threshold, even if the fixed activation temperature point has not been reached. These detectors comply to the UNE 23-007 part 5 standard. Specifications Operating voltage 16 to 28 VDC Current consumption Quiescent at 24 VDC < 100 A Alarm at 24 VDC < 100 mA Remote alarm output NA Heat specification UNE 23.007/5 compliant Working Area 20-30 m² Installation Height (max.) 6m Operating temperature -10 to +60 °C Storage temperature -10 to +70 °C Humidity (non-condensing) 0 - 95% IP rating IP205 Dimensions (h x Ø) 60 mm x 108 mm Ordering Information KV210 Rate-of-Rise Heat Detector E E E E E E E E E E E Very low standby current Two-wire connection No mechanical parts subject to wear and tear Rate-of-rise and thermostatic Remote indicator output on KV210P Latching alarm Compact and water resistant electronics Highly resistant to humidity and corrosion Modern and elegant design No base required Excellent price/quality ratio Conventional Fire Systems Page : 50 KV210P Rate-of-Rise Heat Detectors with remote indicator output The KV210 heat detectors are designed to activate when the temperature exceeds a preset level or when the speed at which the temperature changes is above a set threshold, even if the fixed activation temperature point has not been reached. These detectors comply to the UNE 23-007 part 5 standard. The KV210P has an output for a remote indicator. Specifications Operating voltage 16 to 28 VDC Current consumption Quiescent at 24 VDC < 100 A Alarm at 24 VDC < 100 mA Remote alarm output < 100 mA Heat specification UNE 23.007/5 compliant Working Area 20-30 m² Installation Height (max.) 6m Operating temperature -10 to +60 °C Storage temperature -10 to +70 °C Humidity (non-condensing) 0 - 95% IP rating IP205 Dimensions (h x Ø) 60 mm x 108 mm Ordering Information KV210P Rate-of-Rise Heat Detectors with remote indicator output E E E E E E E E E E E Very low standby current Two-wire connection No mechanical parts subject to wear and tear Rate-of-rise and thermostatic Remote indicator output on KV210P Latching alarm Compact and water resistant electronics Highly resistant to humidity and corrosion Modern and elegant design No base required Excellent price/quality ratio Conventional Fire Systems Page : 51 KL500 Low Profile Ionisation Smoke Detector The KL500 ionisation smoke detector reacts to the presence of both visible and invisible combustion smoke, which makes it ideal for early fire detection, even before flames appear. Specifications Operating voltage 18 to 28 VDC Current consumption Quiescent at 24 VDC 30 mA Alarm at 24 VDC < 70 mA Radio-active source Americium 241 Average activity < 1mCi Remote alarm output < 100 mA Operating temperature -10 to +60 °C Storage temperature -10 to +70 °C Humidity (non-condensing) 0 - 95% IP rating IP205 Dimensions (h x Ø) Head 60 mm x 108 mm Base 24 mm x 103 mm Coverage 60 - 80 m² Maximum installation height 12 m Ordering Information KL500 Low Profile Ionisation Smoke Detector KZ500 S300 Fire detector base for KL500 detectors Surface mount supplement for KL300/KM170 detectors PA25/3L Low current remote LED indicator E E E E E E E E E E Response to the full range of combustion smoke Low standby current No mechanical parts subject to wear and tear High luminosity alarm indicator Remote indicator output available Latching alarm Two wire connection Highly resistant to humidity and corrosion Modern and elegant design Easy installation E More than 90% of materials recyclable (including the radio-active source) Conventional Fire Systems Page : 52 KZ500 Fire detector base for KL500 detectors The KZ500 is a detecor base for use with the KL500 detectors from Kilsen. It allows for a remote indicator to be connected. Specifications Dimensions Diameter 108 mm Height 18 mm Ordering Information KZ500 Fire detector base for KL500 detectors E Polarity sensitive E Remote indicator contact available Conventional Fire Systems Page : 53 KL700 Ionisation detector, conventional Of outstanding performance, efficiency and durability, the 700 series fire detectors are the ideal solution for conventional installations. They are designed specifically for use with the Kilsen NKB600, NK600 and NK700 series conventional fire panels, but are also compatible with most 3rd party industry standard conventional control panels. Specifications Operating voltage 18 to 28 VDC Current consumption Quiescent at 24 VDC 30 A Alarm at 24 VDC < 100 mA Radio-active source Americium 241 Average activity 0.33 +/-0.04 Ci (12.1 +/- 1.5 kBq) Remote alarm output < 100 mA Heat specification Operating temperature -10 to +60 °C Storage temperature -10 to +70 °C Humidity (non-condensing) 0 - 95% IP rating IP43 Number of detectors per zone 20 Recommended protection resistor 300 ohm Head 45 mm x 99 mm Base 24 mm x 103 mm EN54 (BOSEC) * Check current status with local office Ordering Information KL700 detectors E An ultra-fine grid prevents the ingress of dust and Dimensions (h x Ø) Approvals* E Full line consisting of Optical, Ionisation and Heat Ionisation detector, conventional KZ700 Universal fire detector base KZ705 Universal fire detector base with earth connection KZ705D Conventional fire detector base with diode PA25/3L Low current remote LED indicator insects in smoke detectors E Attractive, low-profile design E EN54 approved * E Innovative base compensates for uneven surfaces E Field exchangeable optical chamber for ease of maintenance Conventional Fire Systems Page : 54 KL710 Temperature detector (fixed and rate-of-rise), conventional Of outstanding performance, efficiency and durability, the 700 series fire detectors are the ideal solution for conventional installations. They are designed specifically for use with the Kilsen NKB600, NK600 and NK700 series conventional fire panels, but are also compatible with most 3rd party industry standard conventional control panels. Specifications Operating voltage 18 to 28 VDC Current consumption Quiescent at 24 VDC 70 A Alarm at 24 VDC < 100 mA Radio-active source Average activity Remote alarm output < 100 mA Heat specification Max. & ROR to EN54p5 Operating temperature -10 °C to +70 °C Storage temperature -10 °C to +80 °C Humidity (non-condensing) 95% IP rating IP43 Number of detectors per zone 20 Recommended protection resistor 300 ohm Head 45 mm x 99 mm Base 24 mm x 103 mm EN54 (BOSEC) * Check current status with local office Ordering Information KL710 detectors E An ultra-fine grid prevents the ingress of dust and Dimensions (h x Ø) Approvals* E Full line consisting of Optical, Ionisation and Heat Temperature detector (fixed and rate-of-rise), conventional KZ700 Universal fire detector base KZ705 Universal fire detector base with earth connection KZ705D Conventional fire detector base with diode PA25/3L Low current remote LED indicator insects in smoke detectors E Attractive, low-profile design E EN54 approved * E Innovative base compensates for uneven surfaces E Field exchangeable optical chamber for ease of maintenance Conventional Fire Systems Page : 55 Optical detector, conventional (with field exchangeable optical block) KL731 Of outstanding performance, efficiency and durability, the 700 series fire detectors are the ideal solution for conventional installations. They are designed specifically for use with the Kilsen NKB600, NK600 and NK700 series conventional fire panels, but are also compatible with most 3rd party industry standard conventional control panels. Specifications Operating voltage 9 to 28 VDC Current consumption Quiescent at 24 VDC 85 A Alarm at 24 VDC < 100 mA Radio-active source Average activity Remote alarm output < 100 mA Heat specification Operating temperature -10 °C to +70 °C Storage temperature -10 °C to +70 °C Humidity (non-condensing) 95% IP rating IP43 Number of detectors per zone 20 Recommended protection resistor 300 ohm Dimensions (h x Ø) Head 45 mm x 99 mm Base 24 mm x 103 mm Approvals* EN54 (BOSEC) * Check current status with local office Ordering Information KL731 Optical detector, conventional (with field exchangeable optical block) KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors KZ700 KZ705 KZ705D KZ705R Universal fire detector base Universal fire detector base with earth connection Conventional fire detector base with diode Conventional 12 VDC fire detector base with relay PA25/3L Low current remote LED indicator E An ultra-fine grid prevents the ingress of dust and insects in smoke detectors E Attractive, low-profile design E EN54 approved E Innovative base compensates for uneven surfaces E Field exchangeable optical chamber for ease of maintenance Conventional Fire Systems Page : 56 KL731B Optical detector, conventional - Black Of outstanding performance, efficiency and durability, the 700 series fire detectors are the ideal solution for conventional installations. They are designed specifically for use with the Kilsen NKB600, NK600 and NK700 series conventional fire panels, but are also compatible with most 3rd party industry standard conventional control panels. The KL731B is a black detector specifically designed for use in false ceilings. Specifications Operating voltage 9 to 28 VDC Current consumption Quiescent at 24 VDC 85 A Alarm at 24 VDC < 100 mA Radio-active source Average activity Remote alarm output < 100 mA Heat specification Operating temperature -10 °C to +70 °C Storage temperature -10 °C to +70 °C Humidity (non-condensing) 95% IP rating IP43 Number of detectors per zone 20 Recommended protection resistor 300 ohm Dimensions (h x Ø) Head 45 mm x 99 mm Base 24 mm x 103 mm Approvals* EN54 (BOSEC) * Check current status with local office Ordering Information KL731B Optical detector, conventional - Black KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors E An ultra-fine grid prevents the ingress of dust and insects in smoke detectors E Attractive, low-profile design E EN54 certification marks (*) E Field exchangable optical chamber for ease of maintenance E Black colour Conventional Fire Systems Page : 57 KCT731 Calibration Tool for KL731/DP331I Fire Detectors The KCT731 is a calibration tool to recalibrate the conventional detectors after replacement of the field exchangeable optical block. Specifications Supply 2 x 9 V batteries Dimensions (w x h x d) 104 x 195 x 63 mm Ordering Information KCT731 Calibration Tool for KL731/DP331I Fire Detectors E Easy to use E Simple "go/no-go" function E Battery operated Addressable Fire Systems Page : 58 KL700A Analogue addressable ionisation sensor The KL700A Series uses a microprocessor for measurement and communication. An enhanced protocol ensures the overall integrity and error free operation of the fire system, without compromising speed. All sensors are compatible with a standard base that makes them easily interchangeable and that supports the connection of a remote indicator. Specifications Operating voltage 22 - 38 VDC Current consumption Quiescent @ 38 VDC 200 A In alarm less than 11 mA Alarm indication (Dual LED) White OFF - Red ON Remote alarm output Available Environment Storage temperature -10 °C to +70 °C Operating temperature -10 °C to +60 °C Humidity (non condencing) 95% IP rating IP205 Radioactive source 0.33 ± 0.04 Ci Am 241 Dimensions (h x Ø) 45 mm x 99 mm Ordering Information KL700A Analogue addressable ionisation sensor E E E E E Remote signalling capabilities Easy soft addressing (1-125) SMD technology Reliable communication protocol Full diagnostic self testing E Full range: Ionisation, Optical and Heat and Duel sensors (optical/heat) E Full range of supporting I/O units and accessories E EN54 Approved Addressable Fire Systems Page : 59 KL710A Analogue addressable temperature sensor The KL700A Series uses a microprocessor for measurement and communication. An enhanced protocol ensures the overall integrity and error free operation of the fire system, without compromising speed. All sensors are compatible with a standard base that makes them easily interchangeable and that supports the connection of a remote indicator. Specifications Operating voltage 22 - 38 VDC Current consumption Quiescent @ 38 VDC 250 A In alarm less than 11 mA Alarm indication (Dual LED) White OFF - Red ON Remote alarm output Available Environment Storage temperature -10 °C to +80 °C Operating temperature -10 °C to +70 °C Humidity (non condencing) 95% IP rating IP205 Radioactive source NA Dimensions (H x Ø) 45 mm x 99 mm Ordering Information KL710A Analogue addressable temperature sensor E E E E E E Remote signalling capabilities Fixed and Rate-of-Rise heat detectors Easy soft addressing (1-125) SMD technology Reliable communication protocol Full diagnostic self testing E Full range: Ionisation, Optical and Heat and Duel sensors (optical/heat) E Full range of supporting I/O units and accessories E EN54 Approved Addressable Fire Systems Page : 60 Analogue addressable optical sensor (with field exchangeable chamber) KL731A The KL700A series detectors use a microprocessor for measurement and communication. An enhanced protocol ensures the overall integrity and error free operation of the system, without compromising detection speed. All sensors are compatible with a standard base that makes them easily interchangeable and support the connection of the PA25/3L remote indicator. Specifications Operating voltage 22 - 38 VDC Current consumption Quiescent @ 38 VDC 350 A In alarm Less than 11 mA Alarm indication (Dual LED) Red Remote alarm output Available Environment Storage temperature -10 °C to +70 °C Operating temperature -10 °C to +60 °C Humidity (non condencing) 95% IP rating IP205 Remote signalling capabilities KL731A Analogue addressable optical sensor (with field exchangeable chamber) E E E E E E KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors E Full range: Ionisation, Optical and Heat and Duel KZ700 KZ705 KZ705AS KZ705IAS KZ705I Universal fire detector base Universal fire detector base with earth connection Analogue fire detector base with sounder Analogue fire detector base with isolator and sounder Analogue fire detector base with isolator PA25/3L Low current remote LED indicator Radioactive source NA Dimensions (h x Ø) 45 mm x 99 mm Ordering Information Field exchangeable optical chamber Easy soft addressing (1-125) SMD technology Reliable communication protocol Full diagnostic self testing sensors (optical/heat) E Full range of supporting I/O units and accessories E EN54 Approved E Black Colour Addressable Fire Systems Page : 61 KL731AB Analogue addressable optical detector - Black The KL700A Series uses a microprocessor for measurement and communication. An enhanced protocol ensures the overall integrity and error free operation of the fire system, without compromising speed. All sensors are compatible with a standard base that makes them easily interchangeable and that supports the connection of a remote indicator. The KL731B is a black detector specificlly designed for false ceilings. Specifications Operating voltage 22 - 38 VDC Current consumption Quiescent @ 38 VDC 350 A In alarm Less than 11 mA Alarm indication (Dual LED) Red Remote alarm output Available Environment Storage temperature -10 °C to +70 °C Operating temperature -10 °C to +60 °C Humidity (non condencing) 95% IP rating IP205 Radioactive source NA Dimensions (h x Ø) 45 mm x 99 mm Ordering Information KL731AB Analogue addressable optical detector - Black KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors E E E E E E Remote signalling capabilities Field exchangeable optical chamber Easy soft addressing (1-125) SMD technology Reliable communication protocol Full diagnostic self testing E Full range: Ionisation, Optical and Heat and Duel sensors (optical/heat) E Full range of supporting I/O units and accessories E EN54 Approved E Black Colour Addressable Fire Systems Page : 62 KL735A Analogue addressable dual (optical and thermal) sensor The KL700A Series uses a microprocessor for measurement and communication. An enhanced protocol ensures the overall integrity and error free operation of the fire system, without compromising speed. All sensors are compatible with a standard base that makes them easily interchangeable and that supports the connection of a remote indicator. Specifications Operating voltage 22 - 38 VDC Current consumption Quiescent @ 38 VDC 350 A In alarm Less than 5 mA Alarm indication (Dual LED) Red Remote alarm output Available Environment Storage temperature -10 °C to +70 °C Operating temperature -10 °C to +70 °C Humidity (non condencing) 95% IP rating IP42 Radioactive source NA Dimensions (h x Ø) 51 mm x 99 mm Ordering Information KL735A Analogue addressable dual (optical and thermal) sensor E E E E E E Remote signalling capabilities Fixed and Rate-of-Rise heat detectors Easy soft addressing (1-125) SMD technology Reliable communication protocol Full diagnostic self testing E Full range: Ionisation, Optical and Heat and Duel sensors (optical/heat) E Full range of supporting I/O units and accessories E EN54 Approved Addressable Fire Systems Page : 63 PG700 Fire sensor programmer The PG700 is a handheld device programmer and tester for the KL700A/Dx1500 series detectors. It is battery operated and allows the installer to perform installation tasks (such as device addressing) and maintenance tasks (such as device calibration) in the field without external assistance. Specifications Supply 2 x 9 V batteries Dimensions (w x h x d) 104 x 195 x 63 mm Ordering Information PG700 Fire sensor programmer E Easy to use E Battery operated E 4 User selectable programs -Device analogue value -Change Device Address -Sequential device addressing -KL731A Calibration Detector Bases & Accessories Page : 64 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors KOB700 The KOB700 is an optical replacement chamber for KL731/KL731A and DP331I/DP1561 detectors. It is an inexpensive part that allows easy maintenance of these detectors on site without the need for cleaning solvents or complicated cleaning procedures. Once replaced, the detector performs as if it was a new device. Specifications Dimensions (Ø x h) 65 x 19 mm Ordering Information KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors E E E E Inexpensive Easy replacement Reduces maintenance time No additional tools required KL7A Dust Protector Cover for KL700/A and Dx300/1500 detectors The KL7A is a dust protector cover for the KL700/DI322I and KL731/DP331I conventional, as well as the KL700A/DP1552 and KL731A/DP1561A addressable detectors. It allows for the protection of the detector chamber against the ingress of dust from building materials during construction or renovation of the building. Ordering Information KL7A Dust Protector Cover for KL700/A and Dx300/1500 detectors E Negligible cost E Easy to install and remove E Avoids unnecessary contamination of the detector during building works Detector Bases & Accessories Page : 65 KZ700 Universal fire detector base The KZ700 is a 4 contact universal detector base. It has the ability to compensate for uneven mounting surfaces. It is also available in black for special applications in false ceilings. Specifications Dimensions Diameter 104 mm Height 24 mm Ordering Information KZ700 Universal fire detector base KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black E Polarity sensitive E Universal base fits conventional and analogue detectors E E E E Compensates for uneven surfaces Remote indicator contact available EN54 approved Variant in black also available Detector Bases & Accessories Page : 66 KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black The KZ700B is a black 4 contact universal detecor base for use with the KL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix. It has the ability to compensate for uneven mounting surfaces. Specifications Dimensions Diameter 104 mm Height 24 mm Ordering Information KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black E Polarity sensitive E Universal base fits conventional and analogue detectors E E E E Compensates for uneven surfaces Remote indicator contact available EN54 approved Variant in black also available Detector Bases & Accessories Page : 67 KZ705 Universal fire detector base with earth connection The KZ705 is a 5 contact universal detector base for use with the KL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix. In addition to the normal base and remote indication connectors, the KZ705 also has an additional earth terminal connector to allow for easy terminations of a possible cable screen. Specifications Dimensions (Ø x h) 100 x 29 mm Operating Voltage - Current Consumption - Isolation Current - Isolation Resistance - Sounder Frequency - Sound Output @ 3 mA - @ 5 mA - Environmental Characteristics Operating Temperature -10 to 70 °C Storage Temperature -10 to 70 °C Relative Humidity (max) 95 % (non-cond.) Ordering Information E Polarity sensitive E Universal base fits conventional and analogue detectors KZ705 Universal fire detector base with earth connection E Additional earth terminal available E Remote indicator contact available S700 Surface mount accessory for KZ700 and KZ705 series bases The S700 is a base accessory designed for use with the KZ700 series detector bases. It allows for a surface mount conduit and cable to enter the base from the side. The KZ700 series base fits on top of this accessory. Specifications Dimensions Diameter 95 mm Height 30 mm Ordering Information S700 Surface mount accessory for KZ700 and KZ705 series bases E Surface mount accessory for KZ700 series bases Addressable Fire Systems Page : 68 KZ705I Analogue fire detector base with isolator The KZ705I is a detector base with built in isolator for use with the KL700A/Dx1500 series detectors from GE-Interlogix. The isolator protects the loop from short circuit conditions. A LED on the side of the base indicates the status of the isolator. Specifications Dimensions (Ø x h) 100 x 29 mm Operating Voltage 17 - 34 V Current Consumption 50 A Isolation Current 6 mA Isolation Resistance 140 Mohm Sounder Frequency - Sound Output @ 3 mA - @ 5 mA - Environmental Characteristics Operating Temperature -10 °C to +70 °C Storage Temperature -10 °C to +70 °C Relative Humidity (max) 95 % (non cond.) Ordering Information KZ705I Analogue fire detector base with isolator E E E E E Polarity sensitive Universal base for analogue detectors Additional earth terminal available Remote indicator contact available Built in isolator Addressable Fire Systems Page : 69 KZ705AS Analogue fire detector base with sounder The KZ705AS is a detector base with built in analogue addressable sounder for use with the KL700A/Dx1500 series detectors from GE-Interlogix. The sounder has its own address on the fire panel loop and works independent of the detector. It is fully controlled from the fire panel. Specifications Dimensions (Ø x h) 120 x 58 mm Operating Voltage 22 - 38 V Current Consumption 300 A Quiescent Isolation Current - Isolation Resistance - Sounder Frequency 1 kHz (Continuous) Sound Output @ 3 mA 85 dBA @ 5 mA 90 dBA Environmental Characteristics Operating Temperature -10 °C to +70 °C Storage Temperature -10 °C to +70 °C Relative Humidity (max) 95 % (non cond.) IP Rating IP21c Ordering Information KZ705AS Analogue fire detector base with sounder E E E E E E E Polarity sensitive Universal base for analogue detectors Additional earth terminal available Remote indicator contact available Built in sounder Up to 90 dBA sound output Low current consumption Addressable Fire Systems Page : 70 KZ705IAS Analogue fire detector base with isolator and sounder The KZ705IAS is a detector base with built in analogue addressable sounder and isolator for use with the KL700A/Dx1500 series detectors from GE-Interlogix. The sounder has its own address on the fire panel loop and works independent of the detector. It is fully controlled from the fire panel. The isolator protects the loop from short circuit conditions. Specifications Dimensions (Ø x h) 120 x 58 mm Operating Voltage 22 - 38 V Current Consumption 350 A Quiescent Isolation Current 6 mA Isolation Resistance 140 Mohm Sounder Frequency 1 kHz (Continuous) Sound Output @ 3 mA 85 dBA @ 5 mA 90 dBA Environmental Characteristics Operating Temperature -10 °C to +70 °C Storage Temperature -10 °C to +70 °C Relative Humidity (max) 95 % (non cond.) IP Rating IP21c Ordering Information KZ705IAS Analogue fire detector base with isolator and sounder E E E E E E E E Polarity sensitive Universal base for analogue detectors Additional earth terminal available Remote indicator contact available Built in sounder Up to 90 dBA sound output Low current consumption Built in isolator Conventional Fire Systems Page : 71 KZ705D Conventional fire detector base with diode The KZ705D is a 5 contact universal detector base for use with the KL700/Dx300 series detectors from GE-Interlogix. In addition to the normal base and remote indication connectors, the KZ705D also has an additional earth terminal connector to allow for easy terminations of a possible cable screen. The built in diode is specifically targeted at systems using active end-of-line devices. Specifications Dimensions (Ø x h) 100 x 29 mm Operating Voltage - Current Consumption - Isolation Current - Isolation Resistance - Sounder Frequency - Sound Output @ 3 mA - @ 5 mA - Environmental Characteristics Operating Temperature -10 to 70 °C Storage Temperature -10 to 70 °C Relative Humidity (max) 95 % (non-cond.) Ordering Information KZ705D Conventional fire detector base with diode E E E E E Polarity sensitive Universal base for conventional detectors Additional earth terminal available Remote indicator contact available Built in diode for active end-of-line systems KZ705R Conventional 12 VDC fire detector base with relay The KZ705R is a 5 contact detector base for use with the KL731/DP331I detectors from GE-Interlogix. In addition to the normal base and remote indication connectors, the KZ705R also has an additional earth terminal connector to allow for easy terminations of a possible cable screen. A built in 12 V relay makes it ideal for use on low voltage intrusion systems. Specifications Dimensions (Ø x h) 100 x 29 mm Operating Voltage 12 V ± 10% Current Consumption 12 A Isolation Current - Isolation Resistance - Sounder Frequency - Sound Output @ 3 mA - @ 5 mA - Environmental Characteristics Operating Temperature -10 °C to +70 °C Storage Temperature -10 °C to +70 °C Relative Humdity 95 % (non cond.) Ordering Information KZ705R Conventional 12 VDC fire detector base with relay E E E E Polarity sensitive 12 V relay for 4 wire systems Additional earth terminal available Remote indicator contact available Annunciators Page : 72 PA25/3L Low current remote LED indicator The PA25 remote indicators have been designed for direct connection to fire detectors (conventional and analogue), enabling luminous indication outside the area where the detector is installed. Specifications Electrical Specifications Supply Voltage (Analogue) 5 to 10 VDC Current Consumption 2 to 79 mA Supply Voltage (Conventional) 2 to 5 VDC Current Consumption 6.5 to 61.5 mA Mechanical Specifications Size (w x h x d) 80 x 80 x 42 mm Weight 10 g Box material A.B.S. Colour White Environmental Specifications Protection level IP20 Working temperature -10 to +60 °C Storage temperature -10 to +70 °C Ordering Information PA25/3L Low current remote LED indicator E E E E E E E E E Direct two-wire connection to detector Large angle of visibility - lit up on four sides Low current consumption Flashing option 2 to 10 VDC power supply High luminosity Compatible with third party products IP20 protection level Modern and elegant design E ABS plastic casing with ruby red polycarbonate spy-hole E Shock resistant Addressable Fire Systems Page : 73 KAL410 Conventional Zone Monitor Unit - 1 Zone Allows the connection of one conventional zone to the analogue fire system loop. This zone is constantly monitored. Up to 20 conventional devices may be connected to this zone. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 90 A Quiescent @ 35 V 105 A Alarm < 3 mA Aux. supply (24 VDC) quiescent 200 A + equip Aux. supply (24 VDC) alarm < 85 mA End-of-line resistor 4.7 kohm Relay contact rating NA Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +70°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) 117 x 80 x 44 mm Ordering Information KAL410 Conventional Zone Monitor Unit - 1 Zone E E E E E E Easy numeric addressing Continuous supervision of the conventional zones Surface mount Local alarm indication Externally or loop powered Aesthetically pleasing E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 74 KAL414C Conventional Zone Monitor Unit - 4 Zones Allows the connection of four conventional zones to the analogue fire system loop. These zones are constantly monitored. Up to 20 conventional devices may be connected to any zone. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 135 A Alarm < 5 mA Aux. Supply (24V DC) Quiescent 200 A + equip Aux. Supply (24V DC) Alarm < 360 mA End-of-line resistor 4.7 kOhm Relay contact rating NA Environmental Storage temperature -10 to +50°C Operating temperature -10 to +70°C Relative humidity (non-condensing) 0-95 % Dimensions (l x w x h) 163 x 107 x 36 mm Ordering Information KAL414C Conventional Zone Monitor Unit - 4 Zones E E E E E E E E E E E E E E E Easy numeric addressing Continuous supervision of the conventional zones Surface mount Local alarm indication Externally powered Aesthetically pleasing Part of a family of I/O modules consisting of: - Conventional Zone Monitors - Digital Input Modules - Extinguishing Control Modules - Isolator Modules - Manual Call Points - Output Units - Retention Units - Supervised Output Units for sounder control Addressable Fire Systems Page : 75 KAL426C Extinguishing Control Module The 400 Series modules consists of a complete range of interfaces developed for input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix. The KAL426 allows for the connection and control of one extinguishing area to the addressable fire panel loop. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 210 A Alarm < 10 mA Aux. supply (24 VDC) quiescent 120 mA Aux. supply (24 VDC) alarm <1A End-of-line resistor 4.7 kOhm Relay contact rating 2½ A Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +70°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) 163 x 107 x 36 mm Ordering Information KAL426C Extinguishing Control Module E E E E E Aesthetically pleasing Easy numeric addressing Externally powered Supervised I/O Surface mount E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 76 KAL430 Relay Module - 1 Relay Provides for one potential free relay output for the fire system loop. Each relay allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. The output may be used to activate ventilation controls, warning signs, activation of other alarm devices etc. during fire situations. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 70 A Quiescent @ 35 V 100 A Alarm < 3.5 mA Aux. 24 VDC quiescent 22 mA Aux. 24 VDC alarm < 50 mA End-of-line resistor NA Relay contact rating 2½A @ 250 VAC Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +70°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) Ordering Information KAL430 Relay Module - 1 Relay 117 x 80 x 44 mm E E E E E E Easy numeric addressing Externally or loop powered Normally open / normally closed operation for I/O Surface mount Aesthetically pleasing Local status indication E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 77 KAL434C Addressable Relay Module - 4 Relays Provides for four potential free relay outputs for the fire system loop. Each relay allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. The outputs may be used to activate ventilation controls, warning signs, activation of other alarm devices etc. during fire situations. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 135 A Alarm 10 mA Aux. 24VDC Quiescent 100 A Aux. 24VDC Alarm 10 mA End-of-line resistor NA Relay contact rating 2½A @ 250 VAC Environmental Storage temperature -10 to +50°C Operating temperature -10 to +70°C Relative humidity (non-cond.) 0-95 % Dimensions (l x w x h) 163 x 107 x 36 mm Ordering Information KAL434C Addressable Relay Module - 4 Relays E E E E E E E E E E E E E E E Easy numeric addressing Externally powered Normally open / normally closed operation for I/O Surface mount Aesthetically pleasing Local status indication Part of a family of I/O modules consiting of: - Conventional Zone Monitors - Digital Input Modules - Extinguishing Control Modules - Isolator Modules - Manual Call Points - Output Units - Retention Units - Supervised Output Units for sounder control Addressable Fire Systems Page : 78 KAL440 Supervised Relay Module Allows for the supervision of a single, 24 Volt powered output contact on the fire system loop. This unit may be used to control for e.g. sounders in case of fire conditions, but may also be used to switch any output considered crucial enough to have the cable integrity between the unit and the switch point monitored. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 135 A Alarm < 3.6 mA Aux. 24 VDC quiescent 23 mA Aux. 24 VDC alarm 23 mA + equip End-of-line resistor 4.7 kohm Relay contact rating 1¼ A @ 250 VAC Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +70°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) 117 x 80 x 44 mm Ordering Information KAL440 Supervised Relay Module E E E E E E Easy numeric addressing Externally powered Supervised 24 VDC Output Surface mount Aesthetically pleasing Local status indication E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 79 KAL450 Addressable Manual Call Point The 400 Series modules consists of a complete range of interfaces developed for input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix. The KAL450 is an addressable manual call point for manual fire activation. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 90 A Quiescent @ 35 V 120 A Alarm < 3.5 mA Aux. supply (24 VDC) quiescent NA Aux. supply (24 VDC) alarm NA End-of-line resistor NA Relay contact rating NA Environmental Storage temperature -10 °C to +70°C Operating temperature -10 °C to +50°C Relative humidity 95 % (non condensing) Ingress Protection IP20 Dimensions (L x W x H) 87 x 87 x 20 mm Weight 98 g Ordering Information KAL450 DM715 DM780 DM781 DM782 DM783 DM784 DM785 DM787 DM788 DM790 DM795 DM798 DM799 DM800 Addressable Manual Call Point EN54 universal glass for manual call point Terminal tray for MCP GS card Hinged transparent MCP protection cover BZB black bezel Test key Spacer box, red Surface mounting box with connectors, red Surface mount box without connectors, red Flush mount cradle with connectors Flush mount cradle, connectors & forkgrips Breakable seal for MCP Terminal tray ETT/3 with bezel 3 Resettable element for MCP DM700/KAL450 E E E E E E Easy numeric addressing Loop powered Local test facility Surface or flush mount Aesthetically pleasing Local status indication E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control E Wide range of accessories Manual Call Points Page : 80 DM715 EN54 universal glass for manual call point The DM715 is a universal EN54 approved break glass for the DM700 series and KAL450 manual call points. Ordering Information DM715 EN54 universal glass for manual call point DM800 Resettable element for MCP DM700/KAL450 E E E E Plastic coated to prevent operator injury No glass fragments on breaking No hammer required Approved EN54 part 11 DM782 Hinged transparent MCP protection cover The DM782 anti-tamper plastic cover is a protection cover for the DM700 and KAL450 manual call points. It prevents accidental activation of the alarm by enforcing a two step action i.e. lifting the cover, then activating the alarm. Ordering Information DM782 Hinged transparent MCP protection cover DM798 Breakable seal for MCP E Unobtrusive E Transparent E Protects from accidental alarm activation Manual Call Points Page : 81 DM787 Surface mounting box with connectors, red The DM787 is surface mounting back-box for DM700 series and KAL450 series manual call points. The DM787 is red and has 3 wiring terminals Specifications Material Self-extinguishing Noryl SE100 Colour Red - RAL N°3020 Operating temperature -40° to +85°C Relative humidity max. 90% RV Ordering Information DM787 DM787Y DM787B DM787G DM788 Surface mounting box with connectors, red Surface mounting box with connectors, yellow Surface mounting box with connectors, blue Surface mounting box with connectors, green Surface mount box without connectors, red E Easy to install E For flush mounting of manual call points E Three terminals Addressable Fire Systems Page : 82 KAL460 Digital Input Module Provides a remote input to the fire system loop. The input is constantly monitored and its status communicated to the fire control panel. The input may be activated by closing or opening a potential free contact, depending on the module configuration. This module may be used to monitor any contact by showing its status through the fire control panel e.g. the monitoring of pressure equipment and closure fire break doors. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 135 A Alarm < 10 mA Aux. 24 VDC quiescent 200 A Aux. 24 VDC alarm < 50 mA End-of-line resistor NA Relay contact rating NA Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +70°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) Ordering Information KAL460 Digital Input Module 117 x 80 x 44 mm E E E E E E Easy numeric addressing Externally or loop powered Normally open / normally closed operation for I/O Surface mount Aesthetically pleasing Local status indication E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 83 KAL470 Isolator Module The 400 series modules consist of a complete range of interfaces developed for input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix. The KAL470 is an isolator module in this series that isolates the faulty zone on a fire panel loop during short circuit conditions. The KAL470 does not use an address on the loop. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 135 A Alarm 10 mA Aux. supply (24 VDC) quiescent NA Aux. supply (24 VDC) alarm NA End-of-line resistor NA Relay contact rating NA Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +50°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) Ordering Information KAL470 Isolator Module 75 x 45 x 28 mm E E E E Requires no device address Automatic reset Local status indication Surface mount E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 84 KAL490 Retention Module - 1 Input / 1 Output Provides a remote input and a potential free voltage relay output to the fire system loop. The input signal is constantly monitored and its status displayed on the control panel, whilst the output is fail-to-safe. Auxiliary supply monitoring is also included. The module is used to for e.g. control and monitor doors such as fire break doors. The relay provides the door activation and the input monitors the door status. Specifications Supply voltage 22-38 VDC Current consumption Quiescent @ 24 V 110 A Quiescent @ 35 V 135 A Alarm 10 mA Aux. 24 VDC quiescent 200 A Aux. 24 VDC alarm < 50 mA End-of-line resistor NA Relay contact rating 1A @ 30 VAC/VDC Environmental Storage temperature -10 °C to +50°C Operating temperature -10 °C to +70°C Relative humidity 95 % (non condensing) Dimensions (L x W x H) 117 x 80 x 44 mm Ordering Information KAL490 Retention Module - 1 Input / 1 Output E E E E E E Easy numeric addressing Externally or loop powered Normally open / normally closed operation for I/O Surface mount Aesthetically pleasing Local status indication E Part of family of I/O modules consisting of: -Conventional Zone Monitors -Digital Input Modules -Extinguishing Control Modules -Isolator Modules -Manual Call Points -Output Units -Retention Units -Supervised Output Units for sounder control Addressable Fire Systems Page : 85 SK07A Addressable loop powered siren The SK07A loop powered siren is designed for connection to and control by the KSA700/FP1500 analogue fire detection systems from GE-Interlogix. Communication is done digitally between the fire panel and the sounder. Specifications Electrical Supply Voltage 22 - 38 VDC Quiescent current 300 A Alarm current 6 mA Maximum sound level 87 dBA Mechanical Dimensions 63 mm (h) x 93 mm Ø Maximum cable size 2.5 mm² Fastening Screws 2 x 30 mm Environmental Working temperature -20 °C to +50 °C Storage temperature -20 °C to +70 °C Relative humidity (maximum) 95 % Protection Index IP445 Ordering Information SK07A Addressable loop powered siren E E E E E E E E E EN54 part 3 compliant Up to 87 dBA sound output Low current consumption Low profile IP445 protection level Easy installation Polarity sensitive Rear and side cable entry possible Low and easy maintenance Annunciators Page : 86 KR24B Illuminated warning sign (No text) 24VDC The KR24 is specifically designed as an evacuation warning sign for gas extinguising areas. The KR24B has no text on the backlit display, and text may therefor be added as required for the application. Units supplied with text in various languages are also available. Specifications Electrical Specifications Supply Voltage 18 to 27 VDC Activation Voltage 18 to 27 VDC Current Consumption 600 mA Switching Polarity NA Indicators 24 V 3 W Environmental Specifications Working Temperature -10 to 75 °C Physical Specifications Number of zones NA Buzzer output 80 dB Housing Colour Grey Display Colour Red Weight 700 g Size (w x h x d) 255 x 110 x 50 mm IP Rating IP50 Ordering Information KR24B Illuminated warning sign (No text) 24VDC E E E E Low current consumption Large angle of view Optical and acoustic indications selectable Modern and elegant design Annunciators Page : 87 KR24-ING Illuminated extinguishing waring sign (English version) 24VDC The KR24 is a backlit "No Entry / Extinguishing Release" warning sign to be used with gas extinguishing areas. Warning text is available in various languages. Specifications Electrical Specifications Supply Voltage 18 to 27 VDC Activation Voltage 18 to 27 VDC Current Consumption 600 mA Switching Polarity NA Indicators 24 V 3 W Environmental Specifications Working Temperature -10 to 75 °C Physical Specifications Number of zones NA Buzzer output 80 dB Housing Colour Grey Display Colour Red Weight 700 g Size (w x h x d) 255 x 110 x 50 mm IP Rating IP50 Ordering Information KR24-ING Illuminated extinguishing waring sign (English version) 24VDC E E E E Low Consumption Large angle of vision Optical and acoustic indication selectable Modern and elegant design Annunciators Page : 88 SK07 Low consumption multi-tone alarm siren The SK07 multi-tone siren is designed to sound an acoustic alarm inside buildings. This small, low profile siren combines a high sound output with low power consumption. It complies with the requirements of EN 54 part 3. Specifications Electrical Supply Voltage 22 - 26 VDC Alarm current 3 mA at 85 dBA or less than 20 mA at 95 dBA Maximum sound level 95 dBA Working temperature -20 °C to 50 °C Storage temperature -20 °C to 70 °C Maximum relative humidity 95 % (non condencing) Mechanical Dimensions 63 mm (h) x 93 mm Ø Protection Index IP445 Fastening screws 2 x 30 mm Maximum cable section 2.5 mm² Recommended cable size Single core 1.5 mm² Ordering Information SK07 Low consumption multi-tone alarm siren E E E E E E E E E E E E E E Low profile Easy installation Back and side cable entry Polarity sensitive Connection base included Input and output terminals included Acoustic power output selection Up to 95 dBA sound output Eight different alarm tones Automatic tone change Low current consumption Low maintenance IP445 protection level EN54 part 3 compliant Addressable Fire Systems Page : 89 PCC-Config KSA701/FP1500 Configuration software kit PCC-Config allows easy, menu driven, programming of all the features and settings of the panel. Common texts can be easily copied to sensors and zones. Programming becomes simple as all settings are displayed for the programmers convenience. Specifications Hardware requirements Communication RS232, modem and/or TCP/IP Display VGA or higher resolution Hard disk 2 Gb with 650 Mb free space Keyboard Required Pointing device Required Printer System printer required for printing Processor 133 MHz or higher Pentium-compatible CPU RAM 64 Mb or more Removable media 1.44 Mb stiffy and CD-ROM or DVD drive Software requirements Operating system Win '98, Win 2000, Win XP Ordering Information PCC-Config KSA701/FP1500 Configuration software kit KSP700 KSA702/5 Configuration software kit E Windows based E Complete external configuration of the installation E Configuration possibilities for single and networked fire systems E Local or remote operation via modem or TCP/IP E Standard RS232 communication Addressable Fire Systems Page : 90 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops) PCG-Graphic102 The PCG-Config series consists of 3 software applications. The individual software formats allows the graphic package to grow with the installation. PCG-Config102 operates with a single panel and allows for the configuration of all devices up to a maximum of two loops. Specifications Hardware requirements Communication RS232, modem and/or TCP/IP Display SVGA or higher resolution Hard disk 2 Gb with 650 Mb free space Keyboard Required Pointing device Required Printer System printer required for printing Processor 1 GHz or higher Pentium III-compatible CPU RAM 256 Mb or more Removable media 1.44 Mb stiffy and CD-ROM or DVD drive Software requirements Operating system Windows '98 or Windows 2000 Ordering Information E Bi-directional communication with single panels and networked fire systems PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops) E E E E E E E E E Local or remote connection via modem or TCP/IP Large selection of user configurable icons Visualises device alarms and status of in- and outputs Event texts retrieval from the panel Configurator and operator contol levels Navigation buttons allowed Event logs with reporting facilities Basic drawing package included Imports bmp & drw format graphics Addressable Fire Systems Page : 91 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops) PCG-Graphic105 The PCG-Config series consists of 3 software applications. The individual software formats allows the graphic package to grow with the installation. PCG-Config105 supports a single panel up to 5 loops. Specifications Hardware requirements Communication RS232, modem and/or TCP/IP Display SVGA or higher resolution Hard disk 2 Gb with 650 Mb free space Keyboard Required Pointing device Required Printer System printer required for printing Processor 1 GHz or higher Pentium III-compatible CPU RAM 256 Mb or more Removable media 1.44 Mb stiffy and CD-ROM or DVD drive Software requirements Operating system Windows '98 or Windows 2000 Ordering Information PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops) E Bi-directional communication with single panels and networked fire systems E E E E E E E E E Local or remote connection via modem or TCP/IP Large selection of user configurable icons Visualises device alarms and status of in- and outputs Event texts retrieval from the panel Configurator and operator contol levels Navigation buttons allowed Event logs with reporting facilities Basic drawing package included Imports bmp & drw format graphics Addressable Fire Systems Page : 92 PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel) The PCG-Config series consists of 3 software applications. The individual software formats allows the graphic package to grow with the installation. PCG-ConfigNW allows for monitoring on networked systems with multiple panels. Specifications Hardware requirements Communication RS232, modem and/or TCP/IP Display SVGA or higher resolution Hard disk 2 Gb with 650 Mb free space Keyboard Required Pointing device Required Printer System printer required for printing Processor 1 GHz or higher Pentium III-compatible CPU RAM 256 Mb or more Removable media 1.44 Mb stiffy and CD-ROM or DVD drive Software requirements Operating system Windows '98 or Windows 2000 Ordering Information E Bi-directional communication with single panels and networked fire systems PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel) E E E E E E E E E Local or remote connection via modem or TCP/IP Large selection of user configurable icons Visualises device alarms and status of in- and outputs Event texts retrieval from the panel Configurator and operator contol levels Navigation buttons allowed Event logs with reporting facilities Basic drawing package included Imports bmp & drw format graphics Addressable Fire Systems Page : 93 KSP700 KSA702/5 Configuration software kit The KSP700 provides for a interface for the Kilsen KSA702 and KSA705 analogue addressable fire panels for the up/downloading of the fire panel configuration software from a PC. It is supplied as a kit, including the configuration cable together with PCC-Config, the software configuration program for these panels. Specifications Hardware requirements Communication RS232, modem and/or TCP/IP Display VGA or higher resolution Hard disk 2 Gb with 650 Mb free space Keyboard Required Pointing device Required Printer System printer required for printing Processor 133 MHz or higher Pentium-compatible CPU RAM 64 Mb or more Removable media 1.44 Mb stiffy and CD-ROM or DVD drive Software requirements Operating system Win '98, Win 2000, Win XP Ordering Information KSP700 KSA702/5 Configuration software kit E Windows based E Complete external configuration of the installation E Configuration possibilities for single and networked fire systems E Local or remote operation via modem or TCP/IP E Communications interface included Addressable Fire Systems Page : 94 KSP701 PC Configuration RS232 Cable for KSA701/FP1500 fire panels The KSP701 is a RS232 cable for connecting the KSA701 Series or FP1500 Series fire panels to an industry standard RS232 port on any PC. It is normaly included with all software applications for these panels, but may also be ordered seperately when required. Ordering Information KSP701 PC Configuration RS232 Cable for KSA701/FP1500 fire panels E Complete RS232 cable with connectors Addressable Fire Systems Page : 95 PCC2000 Programming and configuration software PCC2000 allows easy, menu driven, programming of all the panel's features and settings. Common texts can be easily copied while sensors, zones and areas increment or follow automatically. Boolean logic programming becomes simple as inputs and outputs are continuously displayed for the programmer's convenience. Specifications Processor 486 66 MHz RAM 12 Mb Display adapter VGA Hard disk space 20 MB Pointing device MS Mouse Graphical environment Windows 98, 2000, XP Communications ports 1 x RS232 1 x Parallel Ordering Information PCC2000 Programming and configuration software E Provide communication with single fire panels and networked fire systems, both locally or remote via modem E E E E Windows 98, 2000 and XP compatible For use with 2000/1200 series panels Menu driven Full or partial up- and download Addressable Fire Systems Page : 96 PCG-N Graphics package network application with copy protection key 2 Packages allow the graphic package to grow with the installation. The basic version PCG-S operates with a single panel, while the PCG-N supports a network. Upgrades do not require rework on the existing database, drawings, etc. Specifications Processor Pentium II 266 MHz (or better) RAM 64 Mb (or more) Display adapter SVGA or better Hard disk space 200 MB Pointing device MS Mouse, Bus or P/S2 Graphical environment Windows NT Communication ports 1 x RS-232 - Depending on drivers 1 x Parallel - Printer port (for key) Ordering Information PCG-N Graphics package network application with copy protection key E Provide bi-directional communication with single fire panels and networked fire systems, both locally and remote via modem E E E E E E E E E E E E Windows 2000 and NT compatible For use with FP2000, FP1200, FP1100 and FP700 Constructed around Sybase SQL Anywhere Large selection of icons Visualises inputs & outputs Information page per point Get texts from panel Several operator levels and passwords Operator configurable Multiple navigation buttons Event logs Basic drawing package included E Imports .bmp & .wmf drawings from virtually any package E Hardware key protected Addressable Fire Systems Page : 97 PCG-S Graphics package with copy protection key 2 Packages allow the graphic package to grow with the installation. The basic version PCG-S operates with a single panel, while the PCG-N supports a network. Upgrades do not require rework on the existing database, drawings, etc. Specifications Item Recommended Processor Pentium II 266 MHz (or better) RAM 64 Mb (or more) Display adapter SVGA or better Hard disk space 200 MB Pointing device MS Mouse, Bus or P/S2 Graphical environment Windows NT Communication ports 1 x RS-232 - Depending on drivers 1 x Parallel - Printer port (for key) Ordering Information PCG-S Graphics package with copy protection key E Provide bi-directional communication with single fire panels and networked fire systems, both locally and remote via modem E E E E E E E E E E E E Windows 2000 and NT compatible For use with FP2000, FP1200, FP1100 and FP700 Constructed around Sybase SQL Anywhere Large selection of icons Visualises inputs & outputs Information page per point Get texts from panel Several operator levels and passwords Operator configurable Multiple navigation buttons Event logs Basic drawing package included E Imports .bmp & .wmf drawings from virtually any package E Hardware key protected Addressable Fire Systems Page : 98 PCM2000 Maintenance and support software with copy protection key PCM2000 allows local and remote maintenance facilities for 1200/2000 series fire panels. Amongst others, it allows for full panel emulation, data retrieval and central alarm monitoring. Specifications Processor Pentium 133Mhz (or better) RAM 32 Mb (or more) Display Adapter VGA Hard Disk Space 20 MB Pointing Device Bus or P/S2 Mouse Graphical Environment Windows 98, NT or 2000 Communications ports Depending on Drivers Printer port (for key) 1 Parallel Ordering Information PCM2000 Maintenance and support software with copy protection key E Provide communication with single fire panels and networked fire systems, both locally or remote via modem E E E E E E E E Windows 95, 98 and NT compatible For use with FP2000, FP1200 Full panel emulation Data retrieval Central station History log Address book Dynamic Link Library (DLL) for third party integration Special Temperature Detectors Page : 99 ST801 High Temperature Thermal Probe with 2 wire connection The ST801 thermal probe high temperature heat detector is designed to protect from hazards where high temperatures are produced at a specific point. The sensitive element (bulb) can be set at a distance of up to 1 meter from the connection box. The ST801 may be connected via 2 wires directly to a conventional fire panel zone. Specifications Suppy Voltage 24 VDC Current Consumption Quiescent Ø Alarm 100 mA Alarm Monitoring Two wires to conventional zone Capilliary pipe length 1m Probe Dimentions (l x Ø) 150 x 3 mm Dimensions 140 x 100 x 70 mm Colour Grey RAL7032 Working Temperature 50 °C to 300 °C Weight 0.8 kg Ordering Information ST801 High Temperature Thermal Probe with 2 wire connection E Completely metal E Adjustable from 50 to 300 °C E Back and side cable input E Sensitive probe with 1 m of stainless steel capillary piping E E E E E Resistant to heat, grease and humidity Easy installation Easy connection Easy maintenance Ideal for commercial areas Special Temperature Detectors Page : 100 ST802 High Temperature Thermal Probe with relay output The ST802 thermal probe high temperature heat detector is designed to protect from hazards where high temperatures are produced at a specific point. The sensitive element (bulb) can be set at a distance of up to 1 meter from the connection box. The ST802 provides a protential free relay output for alarm indication with COM, NC and NO contacts. Specifications Suppy Voltage 24 VDC Current Consumption Quiescent Ø Alarm 100 mA Alarm Monitoring 5A potential free relay Capilliary pipe length 1m Probe Dimentions (l x Ø) 150 x 3 mm Dimensions 140 x 100 x 70 mm Colour Grey RAL7032 Working Temperature 50 °C to 300 °C Weight 0.6 kg Ordering Information ST802 High Temperature Thermal Probe with relay output E Completely metal E Adjustable from 50 to 300 °C E Back and side cable input E Sensitive probe with 1 m of stainless steel capillary piping E E E E E Resistant to heat, grease and humidity Easy installation Easy connection Easy maintenance Potenial free alarm relay output Door Magnets Page : 101 CR255 Electronic delay control for double-leaf fire doors The CR255 is an electronic delay control unit for use with double-leaf fire doors. It allows for the release of the one leaf of the fire door to be slightly delayed to allow for the two leafs to close properly and in the correct sequence. Ordering Information CR255 Electronic delay control for double-leaf fire doors E Easy to install E May be installed inside the door release magnet housing E 24 VDC operation Content NKB602 NKB604 NKB606 NK702 NK704 NK708 NK712 NK716 NK703 NK706 RB404 SB404 EOL-ACT KLBlack-S KLBlack-B KSA701-1 KSA701-2 NC785 KSA701R KSA701R-24 KSA705 KSA705P KAL701 KAL732 KAL785 KAL791 KSA1204 KSA1208 KSA1264R KSA12255R LC1502 LON2000 LON2000R NC2011 NC2051 NE2011 NE2051 PR2000 RB2016 ZE2064 FRL700 NA704 NC700 NC771 Conventional fire alarm panel with 2 zones Page : 3 Conventional fire alarm panel with 4 zones Page : 4 Conventional fire alarm panel with 6 zones Page : 5 Conventional fire panel with 2 fire alarm zones Page : 6 Conventional fire panel with 4 fire alarm zones Page : 7 Conventional fire panel with 8 fire alarm zones Page : 8 Conventional fire panel with 12 fire alarm zones Page : 9 Conventional fire panel with 16 fire alarm zones Page : 10 Conventional extinguishing control panel with 3 zones Page : 11 Conventional extinguishing control panel with 6 zones Page : 12 Relay module, 4 potential free relays for NK700/Fx400 fire panels Page : 13 Relay module, 4 supervised relays for NK700/Fx400 fire panels Page : 14 Active end-of-line device for use with FP400/KL700 fire panels Page : 15 Black front panel cover (small footprint) Page : 16 Black front panel cover (large footprint) Page : 16 Analogue addressable fire detection panel - 1 loop Page : 17 Analogue addressable fire detection panel - 2 loops Page : 18 RS485 expansion kit for KSA701/FP1500 fire panels Page : 19 KSA701 Series LCD Repeater (mains powered) Page : 20 KSA701 Series LCD Repeater (24VDC powered) Page : 21 Analogue addressable fire panel (expandable to 5 loops) Page : 22 Analogue addressable fire panel with printer (expandable to 5 loops) Page : 23 Loop driver module for KSA702/705 control panels Page : 24 RS232 communications module for KSA702/5 control panels Page : 24 RS485 communications module for KSA702/5 control panels Page : 25 Protocol Converter RS232/485 - Kilsen / Johnsson Control Page : 25 Analogue fire panel, 2 loops upgradable to 4, 64 display zones Page : 26 Addressable fire panel, 2-8 loops, 64-255 display zones upgradable Page : 27 Repeater / emulator with 64 zone indications Page : 28 Global zone repeater, 64 zones expandable up to 255 Page : 29 2-loop extension board for 1200/2000 series fire panels Page : 30 LON700 driver for FP1200 / FP2000 Page : 30 LON driver for FP1200/2000 - closed loop systems Page : 31 ARCNET RS485 network card with single RS485 interface Page : 31 ARCNET network card with single optical interface board Page : 32 RS485 network extension board Page : 32 Fibre optic network extension board Page : 33 Internal printer Page : 33 Relay extension board for 1200/2000 series fire panels Page : 34 64-zone LED extension fire and fault LED Page : 34 LCD repeater Page : 35 LON700 network amplifier (4 way) Page : 36 LON700 interface board Page : 36 LON700 closed loop communication board (no driver) Page : 37 NE771 OCB724 PS700 RB708 SIB716 SOB708 ZI708 KM260/1R3-03 KM260/3R3-03 KM260EXT3-03 KM260C KM170 KZ400 S300 ASD20C ASD20F ASD20FIL KV210 KV210P KL500 KZ500 KL700 KL710 KL731 KL731B KCT731 KL700A KL710A KL731A KL731AB KL735A PG700 KOB700 KL7A KZ700 KZ700B KZ705 S700 KZ705I KZ705AS KZ705IAS KZ705D KZ705R PA25/3L LON700 driver for the NC771 and NA704 Page : 37 LON700 output board with 24 open collector outputs Page : 38 Plug-in power supply 3.5 A Page : 38 LON700 output board with 8 relays Page : 39 Supervised input board 16 way LON700 Page : 39 LON700 output board with 8 supervised outputs Page : 40 8 zone input extension board Page : 40 CO detection control panel - 1 Zone (English Version) Page : 41 CO detection control panel - 3 Zones (English Version) Page : 42 CO detection expansion module (English Version) Page : 43 Blanking plate for KM260 panels Page : 44 CO detector with base and mounting supplement Page : 45 Detector base for KL400/KM170 series devices Page : 46 Surface mount supplement for KL300/KM170 detectors Page : 46 Aspiration Smoke Detector Page : 47 Filter housing for ASD20 Page : 48 Filter only for ASD20 Page : 48 Rate-of-Rise Heat Detector Page : 49 Rate-of-Rise Heat Detectors with remote indicator output Page : 50 Low Profile Ionisation Smoke Detector Page : 51 Fire detector base for KL500 detectors Page : 52 Ionisation detector, conventional Page : 53 Temperature detector (fixed and rate-of-rise), conventional Page : 54 Optical detector, conventional (with field exchangeable optical block) Page : 55 Optical detector, conventional - Black Page : 56 Calibration Tool for KL731/DP331I Fire Detectors Page : 57 Analogue addressable ionisation sensor Page : 58 Analogue addressable temperature sensor Page : 59 Analogue addressable optical sensor (with field exchangeable chamber) Page : 60 Analogue addressable optical detector - Black Page : 61 Analogue addressable dual (optical and thermal) sensor Page : 62 Fire sensor programmer Page : 63 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors Page : 64 Dust Protector Cover for KL700/A and Dx300/1500 detectors Page : 64 Universal fire detector base Page : 65 Universal fire detector base (for KL700/A and Dx300/1500) - Black Page : 66 Universal fire detector base with earth connection Page : 67 Surface mount accessory for KZ700 and KZ705 series bases Page : 67 Analogue fire detector base with isolator Page : 68 Analogue fire detector base with sounder Page : 69 Analogue fire detector base with isolator and sounder Page : 70 Conventional fire detector base with diode Page : 71 Conventional 12 VDC fire detector base with relay Page : 71 Low current remote LED indicator Page : 72 KAL410 KAL414C KAL426C KAL430 KAL434C KAL440 KAL450 DM715 DM782 DM787 KAL460 KAL470 KAL490 SK07A KR24B KR24-ING SK07 PCC-Config PCG-Graphic102 PCG-Graphic105 PCG-GraphicNW KSP700 KSP701 PCC2000 PCG-N PCG-S PCM2000 ST801 ST802 CR255 Conventional Zone Monitor Unit - 1 Zone Page : 73 Conventional Zone Monitor Unit - 4 Zones Page : 74 Extinguishing Control Module Page : 75 Relay Module - 1 Relay Page : 76 Addressable Relay Module - 4 Relays Page : 77 Supervised Relay Module Page : 78 Addressable Manual Call Point Page : 79 EN54 universal glass for manual call point Page : 80 Hinged transparent MCP protection cover Page : 80 Surface mounting box with connectors, red Page : 81 Digital Input Module Page : 82 Isolator Module Page : 83 Retention Module - 1 Input / 1 Output Page : 84 Addressable loop powered siren Page : 85 Illuminated warning sign (No text) 24VDC Page : 86 Illuminated extinguishing waring sign (English version) 24VDC Page : 87 Low consumption multi-tone alarm siren Page : 88 KSA701/FP1500 Configuration software kit Page : 89 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops) Page : 90 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops) Page : 91 Graphic Software for KSA700/FP1500 Fire Systems (multi-panel) Page : 92 KSA702/5 Configuration software kit Page : 93 PC Configuration RS232 Cable for KSA701/FP1500 fire panels Page : 94 Programming and configuration software Page : 95 Graphics package network application with copy protection key Page : 96 Graphics package with copy protection key Page : 97 Maintenance and support software with copy protection key Page : 98 High Temperature Thermal Probe with 2 wire connection Page : 99 High Temperature Thermal Probe with relay output Page : 100 Electronic delay control for double-leaf fire doors Page : 101 www.gesecurity.net IPSCAT-2005-12-6 16:09:40 As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GE Security online or contact your GE Security sales representative.