GE
Security
Kilsen Fire Systems Product Catalogue
g
In this catalogue you will find a wide range of
Fire Protection equipment from GE Security.
GE Security is a global technology leader dedicated
to supporting the needs of the rapidly growing
electronic security industry and to expanding
current technologies, products and services that
GE Security,
unrivalled expertise in
Fire Protection
create revenue growth opportunities for its
customers. As part of the GE family, GE Security
shares the spirit of innovation that has
distinguished GE for well over 100 years. GE
Security's commitment to the ongoing success of
its partners and affiliates means that we maintain
a sharp focus on product and service innovation,
world-class manufacturing practices and
operational excellence.
GE Security is a worldwide organisation with sales
and technical support operations in 27 countries,
and manufacturing and logistics operations in
Europe, the U.S. and China.
GE Security has expertise in all areas of electronic
security, including:
z
Intrusion and Fire Protection
z
Electronic Access and Facility Management
z
Key Management and Remote Access Systems
and Services
z
Fibre Optic Transmission and Reception
Equipment
z
CCTV, Digital Video and Surveillance Equipment
z
Video Multiplexing and Digital Storage
When you're looking for the finest in Fire
Protection products with leading-edge
technology and the backing of a world leader, you
need look no further than this catalogue.
Conventional Fire Systems
Page : 3
NKB602
Conventional fire alarm panel with 2 zones
The NKB600 Series microprocessor controlled, conventional fire panels
incorporate state of the art technology, reliability, ease of installation
and maintenance in a basic package. They are compatible with
conventional detectors such as the Kilsen 200, 300, 500 and 700 series
devices. The NKB602 has 2 conventional zones.
Specifications
Supply Voltage
125/230 VAC @ 50/60 Hz
Mains fuse (Type 5x20 mm)
0.5/0.25 A
Total consumption
< 20 W
Nominal Output Voltage
24 VDC
Batteries
Recommended batteries
2 off 1.9 Ah, 12 V
Fuse Rating
1A
Maximum load current
< 100 mA
Zone
Maximum Load
72 mA
Maximum number of
detectors
20
Ouput voltage
22 to 28 VDC
End-of-line resitance
4k7 Ohm
Manual call point resistance
100 Ohm, 2 W
Outputs
Fire alarm
24 VDC ± 15%, 300 mA
Fault alarm (Fail-to-safe)
24 VDC ± 15%, 100 mA
Environmental
Working temperature
+5 to +40°C
Storage temperature
-10 to +70°C
Relative humidity
95 % (non-condencing)
Physical Characteristics
Size (w x h x d)
305 x 295 x 100 mm
Weight without batteries
3 kg
Ordering Information
NKB602 Conventional fire alarm panel with 2 zones
E
E
E
E
E
Modern, elegant design
Compact models for 2, 4 and 6 zones
Microprocessor controlled
Multilingual keyboard
2 Access levels
E Differentiation between alarms from manual call points
and automatic detectors in the same zone
E Acoustic indications for fire and fault
E Optical indications for fire and fault by zone
E Low maintenance
E Compatible with all ranges of KILSEN conventional
detectors
Conventional Fire Systems
Page : 4
NKB604
Conventional fire alarm panel with 4 zones
The NKB600 Series microprocessor controlled, conventional fire panels
incorporate state of the art technology, reliability, ease of installation
and maintenance in a basic package. They are compatible with
conventional detectors such as the Kilsen 200, 300, 500 and 700 series
devices. The NKB604 has 4 conventional zones.
Specifications
Supply Voltage
125/230 VAC @ 50/60 Hz
Mains fuse (Type 5x20 mm)
0.5/0.25 A
Total consumption
< 20 W
Nominal Output Voltage
24 VDC
Batteries
Recommended batteries
2 off 1.9 Ah, 12 V
Fuse Rating
1A
Maximum load current
< 100 mA
Zone
Maximum Load
72 mA
Maximum number of
detectors
20
Ouput voltage
22 to 28 VDC
End-of-line resitance
4k7 Ohm
Manual call point resistance
100 Ohm, 2 W
Outputs
Fire alarm
24 VDC ± 15%, 300 mA
Fault alarm (Fail-to-safe)
24 VDC ± 15%, 100 mA
Environmental
Working temperature
+5 to +40°C
Storage temperature
-10 to +70°C
Relative humidity
95 % (non-condencing)
Physical Characteristics
Size (w x h x d)
305 x 295 x 100 mm
Weight without batteries
3 kg
Ordering Information
NKB604 Conventional fire alarm panel with 4 zones
E
E
E
E
E
Modern, elegant design
Compact models for 2, 4 and 6 zones
Microprocessor controlled
Multilingual keyboard
2 Access levels
E Differentiation between alarms from manual call points
and automatic detectors in the same zone
E Acoustic indications for fire and fault
E Optical indications for fire and fault by zone
E Low maintenance
E Compatible with all ranges of KILSEN conventional
detectors
Conventional Fire Systems
Page : 5
NKB606
Conventional fire alarm panel with 6 zones
The NKB600 Series microprocessor controlled, conventional fire panels
incorporate state of the art technology, reliability, ease of installation
and maintenance in a basic package. They are compatible with
conventional detectors such as the Kilsen 200, 300, 500 and 700 series
devices. The NKB606 has 6 conventional zones.
Specifications
Supply Voltage
125/230 VAC @ 50/60 Hz
Mains fuse (Type 5x20 mm)
0.5/0.25 A
Total consumption
< 20 W
Nominal Output Voltage
24 VDC
Batteries
Recommended batteries
2 off 1.9 Ah, 12 V
Fuse Rating
1A
Maximum load current
< 100 mA
Zone
Maximum Load
72 mA
Maximum number of
detectors
20
Ouput voltage
22 to 28 VDC
End-of-line resitance
4k7 Ohm
Manual call point resistance
100 Ohm, 2 W
Outputs
Fire alarm
24 VDC ± 15%, 300 mA
Fault alarm (Fail-to-safe)
24 VDC ± 15%, 100 mA
Environmental
Working temperature
+5 to +40°C
Storage temperature
-10 to +70°C
Relative humidity
95 % (non-condencing)
Physical Characteristics
Size (w x h x d)
305 x 295 x 100 mm
Weight without batteries
3 kg
Ordering Information
NKB606 Conventional fire alarm panel with 6 zones
E
E
E
E
E
Modern, elegant design
Compact models for 2, 4 and 6 zones
Microprocessor controlled
Multilingual keyboard
2 Access levels
E Differentiation between alarms from manual call points
and automatic detectors in the same zone
E Acoustic indications for fire and fault
E Optical indications for fire and fault by zone
E Low maintenance
E Compatible with all ranges of KILSEN conventional
detectors
Conventional Fire Systems
Page : 6
NK702
Conventional fire panel with 2 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing control
panels is the ideal solution for small to medium-sized installations. Very
powerful and cost-effective, they are extremely simple to install and
use due to their ergonomic, advanced design. The NK704 has 4
conventional zones.
Specifications
Supply voltage (+10% - 15%)
230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity
2 x 2.3 Ah
Fuse rating
2A
Zone
Maximum load
94 mA
Max. number of detectors per 20
zone
Maximum zone resistance
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Relay outputs (excluding
sounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load
NA
Fuse rating
NA
Auxilliary output
250 mA
24 VDC Resetable output
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95 % (non condensing)
IP rating
IP30
Physical characteristics
Size (mm)
297 (w) x 307 (h) x 105 (d)
Weight (without batteries)
3.6 kg
Ordering Information
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 approved
2 User access levels
2 Monitored sounder outputs
One-man test capability
24 Volt resetable output
External 'Class Change' facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
E Addional optional modules with supervised or relay
NK702 Conventional fire panel with 2 fire alarm zones
outputs
Conventional Fire Systems
Page : 7
NK704
Conventional fire panel with 4 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing control
panels is the ideal solution for small to medium-sized installations. Very
powerful and cost-effective, they are extremely simple to install and
use due to their ergonomic, advanced design. The NK704 has 4
conventional zones.
Specifications
Supply voltage
230 VAC @ 50 Hz (±10%)
Batteries
Capacity
2 x 7.5 Ah
Fuse rating
1A
Zone
Maximum load
72 mA
Max number of detectors
20
Sounders
Maximum load
Relay outputs (excluding
Sounders)
300 mA
2 A @ 250 V
Extinguishing relay outputs
Maximum load
NA
Fuse rating
NA
Open collector outputs
15 mA
Auxilliary output
Maximum load
300 mA
24 V resetable output
Maximum load
150 mA
Reset time
4 seconds
Delays
Sounder selectable
0.15 & 60 s
Relay module
3 to 180 s
Enviroment
Working temperature
+5°C to +40 °C
Relative humidity
95 % (non-condensing)
Ordering Information
NK704 Conventional fire panel with 4 fire alarm zones
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 approved
2 User access levels
2 Monitored sounder outputs
One-man test capability
24 Volt resetable output
External 'Class Change' facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
E Addional optional modules with supervised or relay
outputs
Conventional Fire Systems
Page : 8
NK708
Conventional fire panel with 8 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing control
panels is the ideal solution for small to medium-sized installations. Very
powerful and cost-effective, they are extremely simple to install and
use due to their ergonomic, advanced design. The NK708 has 8
conventional zones.
Specifications
Supply voltage (+10% - 15%)
230 / 110 VAC @ 50 / 60 Hz
Batteries
Capacity
2 x 7.5 Ah
Fuse rating
5A
Zone
Maximum load
94 mA
Max. number of detectors per 20
zone
Maximum zone resistance
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Relay outputs (excluding
sounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load
NA
Fuse rating
NA
Auxilliary output
250 mA
24 VDC Resetable output
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95 % (non condensing)
IP rating
IP30
Physical characteristics
Size (mm)
420 (w) x 335 (h) x 110 (d)
Weight (without batteries)
6.2 kg
Ordering Information
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 approved
2 User access levels
2 Monitored sounder outputs
One-man test capability
24 Volt resetable output
External 'Class Change' facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
E Addional optional modules with supervised or relay
NK708 Conventional fire panel with 8 fire alarm zones
outputs
Conventional Fire Systems
Page : 9
NK712
Conventional fire panel with 12 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing control
panels is the ideal solution for small to medium-sized installations. Very
powerful and cost-effective, they are extremely simple to install and
use due to their ergonomic, advanced design. The NK712 has 12
conventional zones.
Specifications
Supply voltage (+10% - 15%)
230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity
2 x 7.5 Ah
Fuse rating
5A
Zone
Maximum load
94 mA
Max. number of detectors per 20
zone
Maximum zone resistance
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Relay outputs (excluding
sounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load
NA
Fuse rating
NA
Auxilliary output
250 mA
24 VDC Resetable output
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95 % (non condensing)
IP rating
IP30
Physical characteristics
Size (mm)
420 (w) x 335 (h) x 110 (d)
Weight (without batteries)
6.2 kg
Ordering Information
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 approved
2 User access levels
2 Monitored sounder outputs
One-man test capability
24 Volt resetable output
External 'Class Change' facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
E Addional optional modules with supervised or relay
NK712 Conventional fire panel with 12 fire alarm zones
outputs
Conventional Fire Systems
Page : 10
NK716
Conventional fire panel with 16 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing control
panels is the ideal solution for small to medium-sized installations. Very
powerful and cost-effective, they are extremely simple to install and
use due to their ergonomic, advanced design. The NK716 has 16
conventional zones.
Specifications
Supply voltage (+10% - 15%)
230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity
2 x 7.5 Ah
Fuse rating
5A
Zone
Maximum load
94 mA
Max. number of detectors per 20
zone
Maximum zone resistance
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Relay outputs (excluding
sounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load
NA
Fuse rating
NA
Auxilliary output
250 mA
24 VDC Resetable output
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95 % (non condensing)
IP rating
IP30
Physical characteristics
Size (mm)
420 (w) x 335 (h) x 110 (d)
Weight (without batteries)
6.2 kg
Ordering Information
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor-controlled
From 2 up to 16-zones
EN54 approved
2 User access levels
2 Monitored sounder outputs
One-man test capability
24 Volt resetable output
External 'Class Change' facility
Alarm output with potential free relay
Common fault output with potential free relay
External watchdog
Active end-of-line support
E Addional optional modules with supervised or relay
NK716 Conventional fire panel with 16 fire alarm zones
outputs
Conventional Fire Systems
Page : 11
NK703
Conventional extinguishing control panel with 3 zones
The NK703 conventional fire alarm and extinguishing control panels is
the ideal solution for small to medium-sized installations. Very powerful
and cost-effective, they are extremely simple to install and use due to
their ergonomic, advanced design. It has 1 double-knock extinguising
area consisting of two fire zones, and 1 free fire detection zone.
Specifications
Supply voltage (+10% - 15%)
230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity
2 x 7 Ah
Fuse rating
2A
Zone
Maximum load
94 mA
Max. number of detectors per 20
zone
Maximum zone resistance
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Relay outputs (excluding
sounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load
250 mA
Fuse rating
0.3 A
Auxilliary output
250 mA
24 VDC resetable ouput
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95 % (non condensing)
IP rating
IP30
Physical characteristics
Size (mm)
420 (w) x 335 (h) x 110 (d)
Weight (without batteries)
6.2 kg
Ordering Information
NK703 Conventional extinguishing control panel with 3 zones
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor controlled
3 zone (1 ext. area) and 6 zone (2 ext. areas) available
Automatic extinguishing agent release control
2 Access levels
Supervised general sounder output
Supervised extinguishing inputs and outputs
One-man test capability
24 Volt resetable output
External 'class change' facility
Alarm output with potential free relay
General fault output with potential free relay
External watchdog
Conventional Fire Systems
Page : 12
NK706
Conventional extinguishing control panel with 6 zones
The NK706 conventional fire alarm and extinguishing control panels is
the ideal solution for small to medium-sized installations. Very powerful
and cost-effective, they are extremely simple to install and use due to
their ergonomic, advanced design. It has 2 double-knock extinguising
areas consisting of two fire zones each, and 2 free fire detection zones.
Specifications
Supply voltage (+10% - 15%)
230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity
2 x 7 Ah
Fuse rating
2A
Zone
Maximum load
94 mA
Max. number of detectors per 20
zone
Maximum zone resistance
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Relay outputs (excluding
sounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load
250 mA
Fuse rating
0.3 A
Auxilliary output
250 mA
24 VDC resetable ouput
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95 % (non condensing)
IP rating
IP30
Physical characteristics
Size (mm)
420 (w) x 335 (h) x 110 (d)
Weight (without batteries)
6.2 kg
Ordering Information
NK706 Conventional extinguishing control panel with 6 zones
E
E
E
E
E
E
E
E
E
E
E
E
E
Modern, attractive design
Microprocessor controlled
3 zone (1 ext. area) and 6 zone (2 ext. areas) available
Automatic extinguishing agent release control
2 Access levels
Supervised general sounder output
Supervised extinguishing inputs and outputs
One-man test capability
24 Volt resetable output
External 'class change' facility
Alarm output with potential free relay
General fault output with potential free relay
External watchdog
Conventional Fire Systems
Page : 13
RB404
Relay module, 4 potential free relays for NK700/Fx400 fire panels
The RB404 relay expander module provides 4 additional voltage free
relays on the GE Security NK700/FP400/FEC400 conventional fire
panels ranges. It allows for these relays to be allocated to individual
detection zones, or for programming the activation of different relays
depending on the status of one or more zones. Up to 4 of these
modules may be used on every fire panel.
Specifications
Relay rating
Voltage
250 VAC / 30 VDC
Current
10 A
Delay setting
0 to 9 minutes
Ordering Information
RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels
E 4 Potential free relays
E Up to 4 modules may be housed inside the fire panel
cabinet
E Programmable with basic boolen functions
E Power supplied from fire panel bus
E Output delay setting per relay
Conventional Fire Systems
Page : 14
SB404
Relay module, 4 supervised relays for NK700/Fx400 fire panels
The SB404 expander module provides 4 additional supervised relays
that provide 24 VDC outputs on the GE Security NK700/FP400/FEC400
conventional fire panels ranges. These relays may be configured to
power sounders or as standard 24 VDC supervised outputs for other
devices. Relays may be allocated to individual detection zones, or for
programming the activation of different relays depending on the status
of one or more zones. Up to 4 of these modules
may be used on every fire panel.
Specifications
Auxiliary supply
24 VDC
Relay Rating
Voltage
250 VAC / 30 VDC
Current
5A
Delay setting
0 to 9 minutes
Ordering Information
SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels
E 4 Supervised relays
E Up to 4 modules may be housed inside the fire panel
cabinet
E Programmable with basic boolen functions
E Output delay setting per relay
E Configurable for sounder control or as supervised
outputs
Conventional Fire Systems
Page : 15
EOL-ACT
Active end-of-line device for use with FP400/KL700 fire panels
The EOL-ACT is designed for use with the NK700/FP400 fire panels from
GE-Interlogix. It is an active end-of-line device to allow the monitoring
of a conventional zone through a diode base (such as the KZ705D).
Ordering Information
EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels
E Small
E Easy to install
Accessories
Page : 16
KLBlack-S
Black front panel cover (small footprint)
The KLBeige-S is a beige coloured, front panel housing lid for the
FP200/NKB600, FP402 and FP404/NK702 and NK704 series fire panels
from GE Security. It allows the user to change the facure colour of the
panel for colour matching or renewal in case of damage.
Ordering Information
KLBlack-S Black front panel cover (small footprint)
E Customisation of panel colour scheme
E Easy replacement
KLBlack-B
Black front panel cover (large footprint)
The KLBlack-B is a black coloured, front panel housing lid for the FP408,
FP412 and FP416/NK708, NK712 and NK716, the FEC400/NK703 and
NK706, as well the FP1500/KSA701 series fire panels and repeaters
from GE Security. It allows the user to change the facure colour of the
panel for colour matching or renewal in case of damage.
Ordering Information
KLBlack-B Black front panel cover (large footprint)
E Customisation of panel colour scheme
E Easy replacement
Addressable Fire Systems
Page : 17
KSA701-1
Analogue addressable fire detection panel - 1 loop
The KSA701 analogue addressable fire alarm control panel is the ideal
solution for small to medium-sized installations. Very powerful and
cost-effective, it is extremely simple to install and use due to its
ergonomic, advanced design. The panel is supplied in an elegant,
high-quality, conveniently sized, heavy-duty enclosure. The cabinet
allows for enough space for the batteries for the system to be housed
inside the cabinet. The KSA701 is fully compatible with the Kilsen 700A
series detectors and KAL400 series accessories.
Specifications
Supply voltage
110/230 VAC @ 50 Hz (+10% -15%)
Current consumption
(no devices connected)
175 mA Quiest. / 241 mA Alarm
Batteries
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse rating
3A
Charger (Temp. comp. -3 V /
°C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity
250 addresses
Maximum load
400 mA / 26 VDC to 32 VDC
Maximum electrical
characteristics
44 Ohm / 500 nF
Sounders (reverse polarity
supervision)
Maximum load (2 Outputs)
250 mA each / 18 to 24 VDC
Delays (adjustable in 10 s
intervals)
10 to 600 seconds
Relay outputs (potential free)
1 A @ 30 VDC
24 V Auxiliary output
Maximum load
250 mA @ 18 VDC to 28 VDC
Environment
Working temperature
-5°C to +40 °C
Relative humidity
(non-condensing)
0-95%
IP rating
IP30
Physical characteristics
Size
420 mm (w) x 335 (h) x 110 (d)
Weight (without batteries)
6.2 kg
Ordering Information
KSA701-1 Analogue addressable fire detection panel - 1 loop
E
E
E
E
E
E
E
E
E
E
E
E
E
4 x 40 characters LCD display
20 Display zones
EN54 compliant with approvals pending
2 User access levels
2 Monitored sounder outputs
2 Programmable voltage free relays
24 Volt auxiliary output
I/O programming capabilities with Boolean functions
Day/night sensitivity settings
Coincidence within zones
Upload/download and graphic PC software
Panel networking
Installation test capability
Addressable Fire Systems
Page : 18
KSA701-2
Analogue addressable fire detection panel - 2 loops
The KSA701 analogue addressable fire alarm control panel is the ideal
solution for small to medium-sized installations. Very powerful and
cost-effective, it is extremely simple to install and use due to its
ergonomic, advanced design. The panel is supplied in an elegant,
high-quality, conveniently sized, heavy-duty enclosure. The cabinet
allows for enough space for the batteries for the system to be housed
inside the cabinet. The KSA701 is fully compatible with the Kilsen 700A
series detectors and KAL400 series accessories.
Specifications
Supply voltage
110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
Current consumption
(no devices connected)
175 mA Quiescent / 241 mA in alarm
Batteries
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse rating
3A
Charger rating (Temp.
compensated -3 V / °C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity
250 addresses
Maximum load
400 mA / 26 VDC to 32 VDC
Maximum electrical
characteristics
44 Ohm / 500 nF approximately 2 km of 1.5 mm2
diameter cable
Sounders (reverse polarity
supervision)
Maximum load
250 mA each (2 Sounder outputs available) / 18 VDC
to 24 VDC
Delays (software adjustable in 10 to 600 seconds
10 second intervals)
Relay outputs (potential free)
1 A @ 30 VDC
24 V Auxiliary output
Maximum load
250 mA @ 18 VDC to 28 VDC
Environment
Working temperature
-5°C to +40 °C
Relative humidity
(non-condensing)
0-95%
IP rating
IP30
Physical Characteristics
Size
420 mm (w) x 335 (h) x 110 (d)
Weight
6.2 kg without batteries / 10.7 kg with 2 x 7 Ah
batteries
Ordering Information
KSA701-2 Analogue addressable fire detection panel - 2 loops
E
E
E
E
E
E
E
E
E
E
E
E
E
4 x 40 characters LCD display
20 Display zones
EN54 compliant with approvals pending
4 User access levels
2 Monitored sounder outputs
2 Programmable voltage free relays
24 Volt auxiliary output
I/O programming capabilities with Boolean functions
Day/night sensitivity settings
Coincidence within zones
Upload/download and graphic PC software
Panel networking
Installation test capability
Addressable Fire Systems
Page : 19
NC785
RS485 expansion kit for KSA701/FP1500 fire panels
The NC785 RS485 expander allows for an easy upgrade to the
KSA701/FP1500 series addressable fire panels. Each module adds an
additional industry standard RS485 communication port to the panel.
This port could be used for communications with other network nodes
in the fire panel network.
Specifications
Number of ports
1
Communications medium
RS485
Technical specifications
Maximum cable length
1200 m
Communication speed
9600 baud
Cable
CAT5 - twisted with screen
Termination resistance
150 Ohm
Ordering Information
NC785 RS485 expansion kit for KSA701/FP1500 fire panels
E Industry standard RS485 communications
E No hardware configuration required
Addressable Fire Systems
Page : 20
KSA701R
KSA701 Series LCD Repeater (mains powered)
The KSA701R repeater allows the user to monitor and control panels
connected to the KSA700 fire panel network via and RS485 link. It
displays 20 zones in alarm and fault on the face of the panel, whilst all
system messages are displayed on the easy to read, LCD display.
Specifications
Supply voltage
AC version
110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
DC version
24 VDC
Current consumption
175 mA Quiescent / 200 mA in alarm
Battery charger (AC version only)
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse rating
3A
Charger rating
350 mA @ 27.6 VDC @ 20 °C (Temperature
compensated -3 V / °C)
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95% (non condensing)
IP rating
IP30
Physical characteristics
Size
420 mm (w) x 335 (h) x 110 (d)
Weight
6.2 kg without batteries / 10.7 kg with 2 x 7 Ah
batteries
RS232 and RS485 standard
Communication ports
Ordering Information
KSA701R KSA701 Series LCD Repeater (mains powered)
E
E
E
E
E
E
E
Modern, attractive design
4 x 40 characters LCD display
20 Display zones
3 User access levels
24 VDC or 230 VAC models available
Panel networking
Full system control
Addressable Fire Systems
Page : 21
KSA701R-24
KSA701 Series LCD Repeater (24VDC powered)
The KSA701R repeater allows the user to monitor and control panels
connected to the KSA700 fire panel network via an RS485 link. It
displays 20 zones in alarm and fault on the face of the panel, whilst all
system messages are displayed on the easy to read, LCD display.
Specifications
Supply voltage
AC version
110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
DC version
24 VDC
Current consumption
175 mA Quiescent / 200 mA in alarm
Battery charger (AC version only)
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse rating
3A
Charger rating
350 mA @ 27.6 VDC @ 20 °C (Temperature
compensated -3 V / °C)
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95% (non condensing)
IP rating
IP30
Physical characteristics
Size
420 mm (w) x 335 (h) x 110 (d)
Weight
6.2 kg without batteries / 10.7 kg with 2 x 7 Ah
batteries
RS232 and RS485 standard
Communication ports
Ordering Information
KSA701R-24 KSA701 Series LCD Repeater (24VDC powered)
E
E
E
E
E
E
E
Modern, attractive design
4 x 40 characters LCD display
20 Display zones
3 User access levels
24 VDC or 230 VAC models available
Panel networking
Full system control
Addressable Fire Systems
Page : 22
KSA705
Analogue addressable fire panel (expandable to 5 loops)
The KSA700 Series analogue addressable fire panels offer leading-edge
technology for the control of analogue addressable fire detection
devices. Their unique user-friendly programming facilitate the ideal
control environment for either simple or complex fire systems.
Specifications
Supply voltage
230 VAC @ 50 Hz (+10% -15%)
Current consumption
(no devices connected)
175 mA Quiest. / 241 mA Alarm
Batteries
Capacity
2 x 12 V - 6 AH (SLA type)
Fuse rating
4A
Charger (Temp. comp. -3 V /
°C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity
250 addresses
Maximum load
400 mA / 26 VDC to 32 VDC
Maximum electrical
characteristics
44 Ohm / 500 nF
Sounders (reverse polarity
supervision)
Maximum load (2 Outputs)
250 mA each / 18 to 24 VDC
Delays (adjustable in 10 s
intervals)
10 to 600 seconds
Relay outputs (potential free)
1 A @ 30 VDC
24 V Auxiliary output
Maximum load
800 mA @ 18 to 28 VDC
E
E
E
E
4-line, 40-character LCD display
Panel networking capability
Graphic monitoring software
Windows based up/download programming software
E Remote programming and maintenance via modem
and TCP/IP
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95% (non condensing)
IP rating
IP41
Physical characteristics
Size
480 mm (w) x 455 (h) x 140 (d)
Weight (without batteries)
13.6 kg
Ordering Information
KSA705 Analogue addressable fire panel (expandable to 5 loops)
E
E
E
E
Repeater facilities
Powerful auto-configuration functions
Simple program options with on-screen menu selection
EN54 compliant
Addressable Fire Systems
Page : 23
Analogue addressable fire panel with printer (expandable to 5 loops)
KSA705P
The KSA700 Series analogue addressable fire panels offer leading-edge
technology for the control of analogue addressable fire detection
devices. Their unique user-friendly programming facilitate the ideal
control environment for either simple or complex fire systems. The
KSA705P offers an additional internal printer facility.
Specifications
Supply voltage
230 VAC @ 50 Hz (+10% -15%)
Current consumption (no devices 175 mA Quiescent / 241 mA in alarm
connect)
Batteries
Capacity
2 x 12 V - 6 AH (SLA type)
Fuse rating
4A
Charger (Temp. comp. -3 V / 350 mA @ 27.6 VDC @ 20 °C
°C)
Loop characteristics per loop
Capacity
250 addresses
Maximum load
400 mA / 26 VDC to 32 VDC
Maximum electrical
characteristics
44 Ohm / 500 nF approximately 2 km of 1.5 mm2
diameter cable
Sounders (reverse polarity
supervision)
Maximum load
Delays (adjustable in 10 s
intervals)
Relay outputs (potential free)
250 mA each (2 Sounder outputs available) / 18 VDC
to 24 VDC
10 to 600 seconds
1 A @ 30 VDC
24 V Auxiliary output
Maximum load
E
E
E
E
4-line, 40-character LCD display
Panel networking capability
Graphic monitoring software
Windows based up/download programming software
E Remote programming and maintenance via modem
and TCP/IP
800 mA @ 18 VDC to 28 VDC
Environment
Working temperature
-5 °C to +40 °C
Relative humidity
95% (non condensing)
IP rating
IP41
Physical characteristics
Size
480 mm (w) x 455 (h) x 140 (d)
Weight
13.6 kg without batteries / 21.6 kg with 2 x 7 Ah
batteries
Ordering Information
KSA705P Analogue addressable fire panel with printer (expandable to 5 loops)
E
E
E
E
Repeater facilities
Powerful auto-configuration functions
Simple program options with on-screen menu selection
EN54 compliant
Addressable Fire Systems
Page : 24
KAL701
Loop driver module for KSA702/705 control panels
The KAL701 1 loop expander allows for an easy upgrade to the KSA702
and KSA705 analalogue addressable fire panels. Each module consist
of a simple plug in card and requires no additional settings or
connections for full functionality. The KAL701 has loop isolators
supplied on both drivers and allows full class-A loop functionality with
up to 250 device addresses.
Specifications
Number of loops
1
Loop characteristics
Capacity
250 addresses
Maximum load
400 mA / 26 VDC to 32 VDC
Maximum electrical
characteristics
44 Ohm / 500 nF
Maximum loop length
2 km
Ordering Information
KAL701 Loop driver module for KSA702/705 control panels
E Expands the loop capabailities of the KSA702 and
KSA705
E Allows for the connection of an additional 250 devices
per unit
E Two isolated drivers support full class-A operation
E No hardware configuration required
KAL732
RS232 communications module for KSA702/5 control panels
The KAL732 RS232 expander allows for an easy upgrade to the KSA702
and KSA705 analalogue addressable fire panels. Each module adds an
additional industry standard RS232 communication port to the panel.
This port could be used for communications with a PC or for
connections to a printer or modem.
Specifications
Number of ports
1
Communications medium
RS232
Technical specifications
Maximum cable length
15 m
Communication speed
9600 baud
Cable
3 core with screen
Ordering Information
KAL732 RS232 communications module for KSA702/5 control panels
E Industry standard RS232 communications
E No hardware configuration required
Addressable Fire Systems
Page : 25
KAL785
RS485 communications module for KSA702/5 control panels
The KAL785 RS485 expander allows for an easy upgrade to the KSA702
and KSA705 analalogue addressable fire panels. Each module adds an
additional industry standard RS485 communication port to the panel.
This port could be used for communications with other network nodes
in the fire panel network.
Specifications
Number of ports
1
Communications medium
RS485
Technical specifications
Maximum cable length
1200 m
Communication speed
9600 baud
Cable
CAT5 - twisted with screen
Termination resistance
150 Ohm
Ordering Information
KAL785 RS485 communications module for KSA702/5 control panels
E Industry standard RS485 communications
E No hardware configuration required
KAL791
Protocol Converter RS232/485 - Kilsen / Johnsson Control
The KAL791 is a protocol converter for the integration of Kilsen KSA700
analogue fire alarm systems into Johnsson Controls building
management systems. It requires a 24 VDC supply from an auxiliary
power supply source.
Specifications
Supply Voltage
24 VDC
Current Consumption
260 mA
Environment
Working Temperature
-5°C to +40 °C
Relative Humidity
(non-condensing)
0-95%
IP Rating
IP41
Physical Characteristics
Size
390 mm (w) x 420 (h) x 135 (d)
Weight
9.3 kg
Ordering Information
E RS232 or RS485 port options
E Seemless integration with no additional programming
on the fire system
E 24 VDC Supply
KAL791 Protocol Converter RS232/485 - Kilsen / Johnsson Control
KAL732 RS232 communications module for KSA702/5 control panels
KAL785 RS485 communications module for KSA702/5 control panels
Addressable Fire Systems
Page : 26
KSA1204
Analogue fire panel, 2 loops upgradable to 4, 64 display zones
The KSA1204 allows for 2 addressble fire panel loops and 64 display
zones.
Specifications
Supply voltage
230 VAC (+10/-15%) 50 Hz
Supply current (max)
1.5 A
Min. supply current @ 24 VDC
0.2 A
Battery charger rating @ 27.6
VDC
1.6 A
Total supply rating @ 27.6 VDC
2.5 A
Relay rating @ 24 VDC
2A
Weight (no batteries)
8 kg
Dimensions (H x W x D)
440 x 444 x 125 mm
Ordering Information
KSA1204
Analogue fire panel, 2 loops upgradable to 4, 64 display zones
LC1502
LON2000
NC2011
NC2051
NET1200
RB2016
2-loop extension board for 1200/2000 series fire panels
LON700 driver for FP1200 / FP2000
ARCNET RS485 network card with single RS485 interface
ARCNET network card with single optical interface board
Dongle for 1200 series panel networking
Relay extension board for 1200/2000 series fire panels
MOD2000 Modem kit
PCC2000 Programming and configuration software
PCM2000 Maintenance and support software with copy protection key
E
E
E
E
E
E
E
E
E
E
E
E
One man maintenance
Maintenance warning
Soak test
On-line diagnostics and statistics
Power supply for 72 hour autonomy
Floating background compensation
Coincidence within and in between zones
Start-up default mode
Upload/download configuration facilities with PC
I/O programming including Boolean functions
EN54 p2 & 4 and VDS approved
2 or 4 class A loops
Addressable Fire Systems
Page : 27
Addressable fire panel, 2-8 loops, 64-255 display zones upgradable
KSA1208
A versatile, powerful addressable fire panel, 2 to 8 loops, 16 to 64
displayed zones with extensive I/O features. The fire panel can operate
within a 31 panel network and can communicate with global repeaters
and PC graphics. It supports all the 700 series LON devices and
repeaters using a seperate two wire bus. It is truly user-friendly and
provides a generous 8 x 40 backlit graphic display. I/O control is done
via powerful boolean I/O programing. Extensive maintenance features
are provided standard. The KSA1200 series supports 1500 series
sensors and 400 series I/O units.
Specifications
Supply voltage 1
190 - 270 V ac
Supply voltage 2
40 - 60 Hz
160 VA max.
21 - 27 V dc
Current consumption
Quiescent @ 24 V dc (equipped
loop)
800 mA
Alarm current @ 24 V dc
1A
Available auxiliary current in
alarm
3A
Battery charger rating @ 27.5 V
dc
3A
Total supply rating @ 27.5 V dc
4A
Relay rating @ 24 V dc
2A
Weight (no batteries)
15 kg
Dimensions (mm) (H x W x D)
804 x 441 x 109
Ordering Information
KSA1208 Addressable fire panel, 2-8 loops, 64-255 display zones upgradable
E
E
E
E
E
E
E
E
E
E
E
E
One man maintenance
Graphic maintenance
Maintenance warning
Service reminder signal
Soak test
On-line diagnostics and statistics
Floating background compensation
Day/night sensitivity setting
Coincidence within and in between zones
Automatic timed and manual on/off zones
Start-up default mode
Service switch
E Upload/download, remote maintenance and graphic PC
software
E
E
E
E
E
E
I/O programming including Boolean functions
ARCNET panel networking
EN54 approved; certified Bosec, VdS, NFA2P
Networkable "black box" and "global zone" system
Full range of repeater panels
Full range of LON devices
Addressable Fire Systems
Page : 28
KSA1264R
Repeater / emulator with 64 zone indications
A repeater / emulator with 64 displayed fire and fault zones, used in
KSA1200 networked systems. The repeater is connected on the arcnet
network and can operate in a local or global repeater mode. An 80 x 40
backlit graphic display and full indication and control keyboard is
provided standard.
Specifications
Supply voltage
230 Vdc
Current consumption
300 mA max
Weight
15 kg
Dimensions (mm) (H x W x D)
804 x 441 x 109
Ordering Information
KSA1264R Repeater / emulator with 64 zone indications
E 8 x 40 character graphic display
E Arcnet network connection to KSA1200 series fire
panels
E
E
E
E
E
Global repeater function
Comprehensive control and display functions
Emulation function
64 zones fire and fault displayed
230 VAC operation
Addressable Fire Systems
Page : 29
KSA12255R
Global zone repeater, 64 zones expandable up to 255
A repeater/emulator with 64 fire and fault zones, expandable to 255,
used in 1200/2000 series networked systems. The repeater is
connected on the arcnet network and can operate in a local or global
repeater mode. An 80 x 40 character, backlit graphic display and full
indication and control keyboard is provided standard.
Specifications
Supply voltage 1
190 - 270 VAC
40- 60 Hz
160 VA max.
Current consumption
Quiescent
800 mA
Alarm current @ 24 V dc
1A
Available auxiliary current in 3 A
alarm
Battery charger rating @ 27.5 3 A
V dc
Total supply rating
4A
Weight (no batteries)
15 kg
Dimensions (mm H x W x D)
804 x 441 x 109
Ordering Information
KSA12255R Global zone repeater, 64 zones expandable up to 255
LON2000
NE2011
NE2051
ZE2064
LON700 driver for FP1200 / FP2000
RS485 network extension board
Fibre optic network extension board
64-zone LED extension fire and fault LED
E On-line diagnostics and statistics
E Upload/download, remote maintenance and graphic PC
software
E I/O programming including Boolean functions
E ARCNET panel networking
E Full range of 700 series LON devices
Addressable Fire Systems
Page : 30
LC1502
2-loop extension board for 1200/2000 series fire panels
The LC1502 is a 2-loop extension board for 1200/2000 series fire
panels. It allows for 2 additional class-A loops to be inserted into the
fire panel, and supports up to 250 addressable loop devices per loop.
Specifications
Current consumption
Quiescent @ 24 VDC (Fully
equipped loop)
+ 150 mA (252 detectors)
Ordering Information
LC1502 2-loop extension board for 1200/2000 series fire panels
E
E
E
E
LON700 driver for FP1200 / FP2000
FP1200 / FP2000 series
A LON700 driver that connects FP1200 / FP2000 fire panels to LON700
devices
Ordering Information
LON2000 LON700 driver for FP1200 / FP2000
2 Class-A loops
Up to 250 devices per loop (protocol dependent)
Supports various detector protocols
No hardware address required
LON2000
Addressable Fire Systems
Page : 31
LON driver for FP1200/2000 - closed loop systems
LON2000R
The LON2000R is a LON700 driver that connects 1200/2000 series fire
panels to LON700 series devices on a closed loop, CLASS-A LON700
network.
Ordering Information
LON2000R LON driver for FP1200/2000 - closed loop systems
ARCNET RS485 network card with single RS485 interface
The NC2011 is an interface board to connect an RS485 copper network
directly into the 1200/2000 series fire panels. It is supplied with one
NE2011 pre installed.
Ordering Information
NC2011 ARCNET RS485 network card with single RS485 interface
NE2011 RS485 network extension board
NC2011
Addressable Fire Systems
Page : 32
ARCNET network card with single optical interface board
NC2051
The NC2051 is an interface board to connect a fiber optic network
directly into the 1200/2000 series fire panels. It is supplied with one
NE2051 pre installed.
Ordering Information
NC2051 ARCNET network card with single optical interface board
NE2051 Fibre optic network extension board
RS485 network extension board
The NE2011 is a RS485 network extension board for the NC2011 to
allow dual bus and closed ring networks.
Ordering Information
NE2011 RS485 network extension board
NE2011
Addressable Fire Systems
Page : 33
Fibre optic network extension board
NE2051
FP1200 / FP2000 series
An extension board for the NC2051 to allow a fibre optic ring bus
Ordering Information
NE2051 Fibre optic network extension board
Internal printer
The PR2000 is a panel mount, 40-column dot matrix printer to be used
with the 1200/2000 series fire panels. It is supplied with all necessary
accesories to allow easy installation into cabinets that allow for this
option.
Ordering Information
PR2000 Internal printer
PR2000
Addressable Fire Systems
Page : 34
RB2016
Relay extension board for 1200/2000 series fire panels
The RB2016 is an extension board for 1200/2000 series fire panels. It
allows for up to 18 additional potential free relays to be added into the
fire panel cabinet. Depending on the size and hardware configuration
of the panel, up to 4 RB2016s may be included in any panel.
Specifications
Relay Contact Rating
1 A @ 30 VDC / 0.3 A @ 110 VDC / 0.3 A @ 125 VAC
Ordering Information
RB2016 Relay extension board for 1200/2000 series fire panels
E Up to 18 potential free relay outputs
E No hardware address required
64-zone LED extension fire and fault LED
The ZE2064 allows the extension of the zones of the Fx2x128 and
Fx2x255 fire panels and repeaters by 64 additional zones.
Ordering Information
ZE2064 64-zone LED extension fire and fault LED
ZE2064
LON700 Devices
Page : 35
FRL700
LCD repeater
The LON700 LCD repeater is a smart and compact, cost-effective
solution for fire panel repeaters. It is also available as an FBP700 fire
brigade panel for Dutch and Scandinavian norms.
Specifications
Dimensions (l x w x d)
240 x 320 x 60 mm
Weight
1.5 kg
Operating temp °C
-5°C to +40°C
Operating voltage
15 - 30 VDC
Current consumption
Max. quiesent
100 mA
Bus Connection
two wire LON700
Bus Cable
CAT 5
Total number of repeaters
700/1200/2000 Series
15
Ordering Information
FRL700 LCD repeater
E
E
E
E
E
2 wire connection between fire panel and repeaters
Up to 1500 metre bus length
24 Volt power supply
Cost effective repeater solutions
Easily installed, simple operation
E 4 x 20 charater LCD display, common LED's, push
button control
E LON700 module
LON700 Devices
Page : 36
LON700 network amplifier (4 way)
NA704
The NA704 is an interface board to allow an extension of the LON700
network above its normal limitations. It acts as a network amplifier
allowing for reconstruction and re-transmission of the LON700 signal,
as well as allowing for T-offs of the network as required.
Ordering Information
NA704
LON700 network amplifier (4 way)
NE771 LON700 driver for the NC771 and NA704
NE2051 Fibre optic network extension board
LON700 interface board
The NC700 is an interface board to connect a LON700 bus from a fire
panel to a FB7xx 'black box'.
Ordering Information
NC700 LON700 interface board
NC700
LON700 Devices
Page : 37
LON700 closed loop communication board (no driver)
NC771
The NC771 is an interface board to connect a LON bus from a fire
panel to a FB7xx 'black box' panel. It allows for full Class-A type
LON700 networks.
Ordering Information
NC771
LON700 closed loop communication board (no driver)
NE771 LON700 driver for the NC771 and NA704
NE2051 Fibre optic network extension board
LON700 driver for the NC771 and NA704
The NE771 is a LON700 network extension board to allow dual bus and
closed ring networks on the NC771 and the NA771.
Ordering Information
NE771 LON700 driver for the NC771 and NA704
NE771
LON700 Devices
Page : 38
LON700 output board with 24 open collector outputs
OCB724
The OCB724 is a 24 way open collector board used in a LON700
system.
Ordering Information
OCB724 LON700 output board with 24 open collector outputs
Plug-in power supply 3.5 A
The PS700 power supply can be used to extend the power output in
LON700 systems.
Ordering Information
PS700 Plug-in power supply 3.5 A
PS700
LON700 Devices
Page : 39
LON700 output board with 8 relays
RB708
The RB708 is an eight way relay board used in LON700 systems.
Specifications
Number of outputs
8
Relay contact rating
Switching current
2A
Switching volage
42V ac/dc
Switching power
60W
Ordering Information
RB708 LON700 output board with 8 relays
Supervised input board 16 way LON700
The SIB716 is a sixteen way input board used in LON700 systems.
Ordering Information
SIB716 Supervised input board 16 way LON700
SIB716
LON700 Devices
Page : 40
LON700 output board with 8 supervised outputs
SOB708
The SOB708 provides eight supervised outputs that can be used in
LON700 systems.
Specifications
Number of outputs
8
Output type
polarity reversal
End of line resistor
5.6 Kohm
Output current per output
500mA
Total current for all outputs
2A
Open circuit
>27 Kohm
Normal
1.2 - 18 Kohm
Short circuit
< 470 ohm
Ordering Information
SOB708 LON700 output board with 8 supervised outputs
8 zone input extension board
The ZI708 is an eight zone input expansion board for LON700
compatible systems. It allows for the connection of up to 8
conventional fire detector zones and is compatible with most industry
standard conventional detectors.
Ordering Information
ZI708 8 zone input extension board
ZI708
Gas Detection
Page : 41
KM260/1R3-03
CO detection control panel - 1 Zone (English Version)
The KM-Series CO detection system is designed for applications such
as vehicle parking areas where concentrations of CO may accumulate.
The range is compliant with the UNE23.300/84 standard. The KM260/1
is a 1 (upgradable to 2) zone control unit, using KM170 detectors.
Specifications
Power supply
Mains supply
230 VAC ±10% 50 Hz
Power consumption
95 W (max)
Zone configuration
Zone input voltage
10-20 VDC/VAC
Sensitiviy
0-300 ppm
Cable requirement
3 core 1.5 mm²
Cable length (max)
350 m
No. of detectors (max)
15
No. of zones (max)
2
Mechanical
Housing (w x h x d)
275 x 335 x 130 mm
Weight
6 kg
Ordering Information
KM260/1R3-03 CO detection control panel - 1 Zone (English Version)
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Designed according to norm 23300/84
Miner CDM8001 and CDM8002 standard password
LGAI 154.909 and 96013132 standard certification
Easy to use
Low current consumption
Direct reading of measured levels
Easy installation
Extraction relays and alarm outputs per area
From 1 to 5 areas
3-wire system
Modular design
Up to 15 detectors per zone
10 seconds response time
Elegant design
Supervision of all zone lines
Available in various languages
Gas Detection
Page : 42
KM260/3R3-03
CO detection control panel - 3 Zones (English Version)
The KM-Series CO detection system is designed for applications such
as vehicle parking areas where concentrations of CO may accumulate.
The range is compliant with the UNE23.300/84 standard. The KM260/3
is a 3 (upgradable to 5) zone control unit, using KM170 detectors.
Specifications
Power supply
Mains supply
230 VAC ±10% 50 Hz
Power consumption
95 W (max)
Zone configuration
Zone input voltage
10-20 VDC/VAC
Sensitiviy
0-300 ppm
Cable requirement
3 core 1.5 mm²
Cable length (max)
350 m
No. of detectors (max)
15
No. of zones (max)
5
Mechanical
Housing (w x h x d)
470 x 335 x 130 mm
Weight
10.2 kg
Ordering Information
KM260/3R3-03 CO detection control panel - 3 Zones (English Version)
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Designed according to norm 23300/84
Miner CDM8001 and CDM8002 standard password
LGAI 154.909 and 96013132 standard certification
Easy to use
Low current consumption
Direct reading of measured levels
Easy installation
Extraction relays and alarm outputs per area
From 1 to 5 areas
3-wire system
Modular design
Up to 15 detectors per zone
10 seconds response time
Elegant design
Supervision of all zone lines
Available in various languages
Gas Detection
Page : 43
KM260EXT3-03
CO detection expansion module (English Version)
The KM260 is an expansion module for the KM260-Series CO panels
from GE-Interlogix. It allows for an additional monitoring zone to be
added to the control panel, each module allowing for an additional 15
sensors to be connected.
Specifications
Power supply
Mains supply
230 VAC ±10% 50 Hz
Power consumption
95 W (max)
Zone configuration
Zone input voltage
10-20 VDC/VAC
Sensitiviy
0-300 ppm
Cable requirement
3 core 1.5 mm²
Cable length (max)
350 m
No. of detectors (max)
15
No. of zones (max)
1
Ordering Information
KM260EXT3-03 CO detection expansion module (English Version)
E
E
E
E
E
E
E
E
E
E
E
E
E
Designed according to norm 23300/84
Miner CDM8001 and CDM8002 standard password
LGAI 154.909 and 96013132 standard certification
Easy to use
Low current consumption
Direct reading of measured levels
Easy installation
Extraction relays and alarm outputs per area
3-wire system
Up to 15 detectors per zone
10 seconds response time
Supervision of zone line
Available in various languages
Gas Detection
Page : 44
Blanking plate for KM260 panels
The blanking plate is used on KM260 panels during upgrading of
modules to cover up any unused positions that may exist on the panel.
Ordering Information
KM260C Blanking plate for KM260 panels
KM260C
Gas Detection
Page : 45
KM170
CO detector with base and mounting supplement
The KM170 detector is specifically designed to react to the presence of
carbon monoxide. The design complies with the requirements of the
UNE 23-300 standard.
Specifications
Sensor type
TGS semicondictor
Useful life
4 years
Electrical characteristics
Supply voltage
10 to 20 VDC
Quiescent current
35 mA
Reaction time
10 s
Environmental
Operating temperature
0 °C to +40 °C
Protection index
IP205
Mechanical
Size (h x Ø)
81 x 109 mm
Weight
115 g
Material and colour
ABS white
Installation
Number of detectors per zone 15
Covarage
300 m²
Ordering Information
KM170 CO detector with base and mounting supplement
E Complies with the requirements of the UNE23-300
standard
E
E
E
E
Microprocessor based
Resolution of up to 5 ppm
Response time of 10 s
Low current consumption
E Local status indication of:
-Normal operation
-50ppm detected
-Fault
E Useful life of up to 4 years
Gas Detection
Page : 46
KZ400
Detector base for KL400/KM170 series devices
The KZ400 base is designed to be used with the KL400 series detectors,
but may also be used as a substitution base for KM170 CO detectors.
Specifications
Dimensions
Diameter
107 mm
Height
22 mm
Ordering Information
KZ400 Detector base for KL400/KM170 series devices
E Polarity sensitive
E Remote indicator contact available
S300
Surface mount supplement for KL300/KM170 detectors
The S300 is a base accessory designed for use with the KZ300 and
KZ400 detector base. It allows for a surface mount conduit and cable
to enter the base from the side. The KZ300 and KZ400 base fits on top
of this accessory. The S300 can also be used with KM170 CO detectors.
Specifications
Dimensions
Diameter
107 mm
Height
25 mm
Ordering Information
S300 Surface mount supplement for KL300/KM170 detectors
E Surface mount accessory for KZ300
E May be used with KM170 CO Detectors
Aspiration Systems
Page : 47
ASD20C
Aspiration Smoke Detector
The ASD20 Aspiration Smoke Detector consists of an analysis chamber
with one or two smoke detectors, connected to standard 25 mm Ø
PVC piping. The detectors can be of conventional or analogue
technology, ionisation or optical.
Specifications
Power supply voltage
24 VDC
Current Consumption
Standby
250 mA
1st alarm
280 mA
2nd alarm
320 mA
Fault
220 mA
Environmental Characteristics
Working temperature
-10 to +60°C
Storage temperature
-10 to +70°C
Relative humidity
<95%
Physical Characteristics
Size
314 x 254 x 115
Weight
4 kg
Colour
RAL9999
Material
Polycarbonate
Cable input
3 x PG11
Wire cross-section
Max. 1.5 mm²
Coverage area per intake
30 m²
Maximum num. of intakes
12
DIN 8062-type PVC pipes
Ø25 mm
Useful lifetime of motor
65 000 hours at 40°C
Ordering Information
ASD20C
Aspiration Smoke Detector
ASD20F Filter housing for ASD20
ASD20FIL Filter only for ASD20
E Used with conventional or analogue detectors
E Direct connection to an analogue loop or stand-alone
operation
E
E
E
E
E
Alarm 1, alarm 2 and fault relay outputs
24 VDC power supply
Simple and robust architecture
30 m² coverage per sample intake
Standard 25 mm PVC piping system
E Installation of piping in I-shape and U-shape
(symmetrical or assymmetrical)
E Continuous supervision of pipe flow volume
Aspiration Systems
Page : 48
ASD20F
Filter housing for ASD20
The ASD20F is an aluminium filter housing for the ASD20 aspiration
detection system. It houses and protects the the air filter, the ASD20FIL,
that has to be ordered seperately.
Ordering Information
ASD20F
Filter housing for ASD20
ASD20FIL Filter only for ASD20
E Robust, light weight, aluminium construction
E Easy to install
E Easy filter replacement
Filter only for ASD20
Filter only for ASD20 Aspiration Detector.
Ordering Information
ASD20FIL Filter only for ASD20
ASD20FIL
Conventional Fire Systems
Page : 49
KV210
Rate-of-Rise Heat Detector
The KV210 heat detectors are designed to activate when the
temperature exceeds a preset level or when the speed at which the
temperature changes is above a set threshold, even if the fixed
activation temperature point has not been reached. These detectors
comply to the UNE 23-007 part 5 standard.
Specifications
Operating voltage
16 to 28 VDC
Current consumption
Quiescent at 24 VDC
< 100 A
Alarm at 24 VDC
< 100 mA
Remote alarm output
NA
Heat specification
UNE 23.007/5 compliant
Working Area
20-30 m²
Installation Height (max.)
6m
Operating temperature
-10 to +60 °C
Storage temperature
-10 to +70 °C
Humidity (non-condensing)
0 - 95%
IP rating
IP205
Dimensions (h x Ø)
60 mm x 108 mm
Ordering Information
KV210 Rate-of-Rise Heat Detector
E
E
E
E
E
E
E
E
E
E
E
Very low standby current
Two-wire connection
No mechanical parts subject to wear and tear
Rate-of-rise and thermostatic
Remote indicator output on KV210P
Latching alarm
Compact and water resistant electronics
Highly resistant to humidity and corrosion
Modern and elegant design
No base required
Excellent price/quality ratio
Conventional Fire Systems
Page : 50
KV210P
Rate-of-Rise Heat Detectors with remote indicator output
The KV210 heat detectors are designed to activate when the
temperature exceeds a preset level or when the speed at which the
temperature changes is above a set threshold, even if the fixed
activation temperature point has not been reached. These detectors
comply to the UNE 23-007 part 5 standard. The KV210P has an output
for a remote indicator.
Specifications
Operating voltage
16 to 28 VDC
Current consumption
Quiescent at 24 VDC
< 100 A
Alarm at 24 VDC
< 100 mA
Remote alarm output
< 100 mA
Heat specification
UNE 23.007/5 compliant
Working Area
20-30 m²
Installation Height (max.)
6m
Operating temperature
-10 to +60 °C
Storage temperature
-10 to +70 °C
Humidity (non-condensing)
0 - 95%
IP rating
IP205
Dimensions (h x Ø)
60 mm x 108 mm
Ordering Information
KV210P Rate-of-Rise Heat Detectors with remote indicator output
E
E
E
E
E
E
E
E
E
E
E
Very low standby current
Two-wire connection
No mechanical parts subject to wear and tear
Rate-of-rise and thermostatic
Remote indicator output on KV210P
Latching alarm
Compact and water resistant electronics
Highly resistant to humidity and corrosion
Modern and elegant design
No base required
Excellent price/quality ratio
Conventional Fire Systems
Page : 51
KL500
Low Profile Ionisation Smoke Detector
The KL500 ionisation smoke detector reacts to the presence of both
visible and invisible combustion smoke, which makes it ideal for early
fire detection, even before flames appear.
Specifications
Operating voltage
18 to 28 VDC
Current consumption
Quiescent at 24 VDC
30 mA
Alarm at 24 VDC
< 70 mA
Radio-active source
Americium 241
Average activity
< 1mCi
Remote alarm output
< 100 mA
Operating temperature
-10 to +60 °C
Storage temperature
-10 to +70 °C
Humidity (non-condensing)
0 - 95%
IP rating
IP205
Dimensions (h x Ø)
Head
60 mm x 108 mm
Base
24 mm x 103 mm
Coverage
60 - 80 m²
Maximum installation height
12 m
Ordering Information
KL500
Low Profile Ionisation Smoke Detector
KZ500
S300
Fire detector base for KL500 detectors
Surface mount supplement for KL300/KM170 detectors
PA25/3L Low current remote LED indicator
E
E
E
E
E
E
E
E
E
E
Response to the full range of combustion smoke
Low standby current
No mechanical parts subject to wear and tear
High luminosity alarm indicator
Remote indicator output available
Latching alarm
Two wire connection
Highly resistant to humidity and corrosion
Modern and elegant design
Easy installation
E More than 90% of materials recyclable (including the
radio-active source)
Conventional Fire Systems
Page : 52
KZ500
Fire detector base for KL500 detectors
The KZ500 is a detecor base for use with the KL500 detectors from
Kilsen. It allows for a remote indicator to be connected.
Specifications
Dimensions
Diameter
108 mm
Height
18 mm
Ordering Information
KZ500 Fire detector base for KL500 detectors
E Polarity sensitive
E Remote indicator contact available
Conventional Fire Systems
Page : 53
KL700
Ionisation detector, conventional
Of outstanding performance, efficiency and durability, the 700 series
fire detectors are the ideal solution for conventional installations. They
are designed specifically for use with the Kilsen NKB600, NK600 and
NK700 series conventional fire panels, but are also compatible with
most 3rd party industry standard conventional control panels.
Specifications
Operating voltage
18 to 28 VDC
Current consumption
Quiescent at 24 VDC
30 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Americium 241
Average activity
0.33 +/-0.04 Ci (12.1 +/- 1.5 kBq)
Remote alarm output
< 100 mA
Heat specification
Operating temperature
-10 to +60 °C
Storage temperature
-10 to +70 °C
Humidity (non-condensing)
0 - 95%
IP rating
IP43
Number of detectors per zone
20
Recommended protection
resistor
300 ohm
Head
45 mm x 99 mm
Base
24 mm x 103 mm
EN54 (BOSEC)
* Check current status with local
office
Ordering Information
KL700
detectors
E An ultra-fine grid prevents the ingress of dust and
Dimensions (h x Ø)
Approvals*
E Full line consisting of Optical, Ionisation and Heat
Ionisation detector, conventional
KZ700
Universal fire detector base
KZ705
Universal fire detector base with earth connection
KZ705D Conventional fire detector base with diode
PA25/3L Low current remote LED indicator
insects in smoke detectors
E Attractive, low-profile design
E EN54 approved *
E Innovative base compensates for uneven surfaces
E Field exchangeable optical chamber for ease of
maintenance
Conventional Fire Systems
Page : 54
KL710
Temperature detector (fixed and rate-of-rise), conventional
Of outstanding performance, efficiency and durability, the 700 series
fire detectors are the ideal solution for conventional installations. They
are designed specifically for use with the Kilsen NKB600, NK600 and
NK700 series conventional fire panels, but are also compatible with
most 3rd party industry standard conventional control panels.
Specifications
Operating voltage
18 to 28 VDC
Current consumption
Quiescent at 24 VDC
70 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Average activity
Remote alarm output
< 100 mA
Heat specification
Max. & ROR to EN54p5
Operating temperature
-10 °C to +70 °C
Storage temperature
-10 °C to +80 °C
Humidity (non-condensing)
95%
IP rating
IP43
Number of detectors per zone
20
Recommended protection
resistor
300 ohm
Head
45 mm x 99 mm
Base
24 mm x 103 mm
EN54 (BOSEC)
* Check current status with local
office
Ordering Information
KL710
detectors
E An ultra-fine grid prevents the ingress of dust and
Dimensions (h x Ø)
Approvals*
E Full line consisting of Optical, Ionisation and Heat
Temperature detector (fixed and rate-of-rise), conventional
KZ700
Universal fire detector base
KZ705
Universal fire detector base with earth connection
KZ705D Conventional fire detector base with diode
PA25/3L Low current remote LED indicator
insects in smoke detectors
E Attractive, low-profile design
E EN54 approved *
E Innovative base compensates for uneven surfaces
E Field exchangeable optical chamber for ease of
maintenance
Conventional Fire Systems
Page : 55
Optical detector, conventional (with field exchangeable optical block)
KL731
Of outstanding performance, efficiency and durability, the 700 series
fire detectors are the ideal solution for conventional installations. They
are designed specifically for use with the Kilsen NKB600, NK600 and
NK700 series conventional fire panels, but are also compatible with
most 3rd party industry standard conventional control panels.
Specifications
Operating voltage
9 to 28 VDC
Current consumption
Quiescent at 24 VDC
85 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Average activity
Remote alarm output
< 100 mA
Heat specification
Operating temperature
-10 °C to +70 °C
Storage temperature
-10 °C to +70 °C
Humidity (non-condensing)
95%
IP rating
IP43
Number of detectors per zone
20
Recommended protection
resistor
300 ohm
Dimensions (h x Ø)
Head
45 mm x 99 mm
Base
24 mm x 103 mm
Approvals*
EN54 (BOSEC)
* Check current status with local
office
Ordering Information
KL731
Optical detector, conventional (with field exchangeable optical block)
KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
KZ700
KZ705
KZ705D
KZ705R
Universal fire detector base
Universal fire detector base with earth connection
Conventional fire detector base with diode
Conventional 12 VDC fire detector base with relay
PA25/3L Low current remote LED indicator
E An ultra-fine grid prevents the ingress of dust and
insects in smoke detectors
E Attractive, low-profile design
E EN54 approved
E Innovative base compensates for uneven surfaces
E Field exchangeable optical chamber for ease of
maintenance
Conventional Fire Systems
Page : 56
KL731B
Optical detector, conventional - Black
Of outstanding performance, efficiency and durability, the 700 series
fire detectors are the ideal solution for conventional installations. They
are designed specifically for use with the Kilsen NKB600, NK600 and
NK700 series conventional fire panels, but are also compatible with
most 3rd party industry standard conventional control panels. The
KL731B is a black detector specifically designed for use in false
ceilings.
Specifications
Operating voltage
9 to 28 VDC
Current consumption
Quiescent at 24 VDC
85 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Average activity
Remote alarm output
< 100 mA
Heat specification
Operating temperature
-10 °C to +70 °C
Storage temperature
-10 °C to +70 °C
Humidity (non-condensing)
95%
IP rating
IP43
Number of detectors per zone
20
Recommended protection
resistor
300 ohm
Dimensions (h x Ø)
Head
45 mm x 99 mm
Base
24 mm x 103 mm
Approvals*
EN54 (BOSEC)
* Check current status with local
office
Ordering Information
KL731B Optical detector, conventional - Black
KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
E An ultra-fine grid prevents the ingress of dust and
insects in smoke detectors
E Attractive, low-profile design
E EN54 certification marks (*)
E Field exchangable optical chamber for ease of
maintenance
E Black colour
Conventional Fire Systems
Page : 57
KCT731
Calibration Tool for KL731/DP331I Fire Detectors
The KCT731 is a calibration tool to recalibrate the conventional
detectors after replacement of the field exchangeable optical block.
Specifications
Supply
2 x 9 V batteries
Dimensions (w x h x d)
104 x 195 x 63 mm
Ordering Information
KCT731 Calibration Tool for KL731/DP331I Fire Detectors
E Easy to use
E Simple "go/no-go" function
E Battery operated
Addressable Fire Systems
Page : 58
KL700A
Analogue addressable ionisation sensor
The KL700A Series uses a microprocessor for measurement and
communication. An enhanced protocol ensures the overall integrity
and error free operation of the fire system, without compromising
speed. All sensors are compatible with a standard base that makes
them easily interchangeable and that supports the connection of a
remote indicator.
Specifications
Operating voltage
22 - 38 VDC
Current consumption
Quiescent @ 38 VDC
200 A
In alarm
less than 11 mA
Alarm indication (Dual LED)
White OFF - Red ON
Remote alarm output
Available
Environment
Storage temperature
-10 °C to +70 °C
Operating temperature
-10 °C to +60 °C
Humidity (non condencing)
95%
IP rating
IP205
Radioactive source
0.33 ± 0.04 Ci Am 241
Dimensions (h x Ø)
45 mm x 99 mm
Ordering Information
KL700A Analogue addressable ionisation sensor
E
E
E
E
E
Remote signalling capabilities
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
E Full range: Ionisation, Optical and Heat and Duel
sensors (optical/heat)
E Full range of supporting I/O units and accessories
E EN54 Approved
Addressable Fire Systems
Page : 59
KL710A
Analogue addressable temperature sensor
The KL700A Series uses a microprocessor for measurement and
communication. An enhanced protocol ensures the overall integrity
and error free operation of the fire system, without compromising
speed. All sensors are compatible with a standard base that makes
them easily interchangeable and that supports the connection of a
remote indicator.
Specifications
Operating voltage
22 - 38 VDC
Current consumption
Quiescent @ 38 VDC
250 A
In alarm
less than 11 mA
Alarm indication (Dual LED)
White OFF - Red ON
Remote alarm output
Available
Environment
Storage temperature
-10 °C to +80 °C
Operating temperature
-10 °C to +70 °C
Humidity (non condencing)
95%
IP rating
IP205
Radioactive source
NA
Dimensions (H x Ø)
45 mm x 99 mm
Ordering Information
KL710A Analogue addressable temperature sensor
E
E
E
E
E
E
Remote signalling capabilities
Fixed and Rate-of-Rise heat detectors
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
E Full range: Ionisation, Optical and Heat and Duel
sensors (optical/heat)
E Full range of supporting I/O units and accessories
E EN54 Approved
Addressable Fire Systems
Page : 60
Analogue addressable optical sensor (with field exchangeable chamber)
KL731A
The KL700A series detectors use a microprocessor for measurement
and communication. An enhanced protocol ensures the overall
integrity and error free operation of the system, without compromising
detection speed.
All sensors are compatible with a standard base that makes them
easily interchangeable and support the connection of the PA25/3L
remote indicator.
Specifications
Operating voltage
22 - 38 VDC
Current consumption
Quiescent @ 38 VDC
350 A
In alarm
Less than 11 mA
Alarm indication (Dual LED)
Red
Remote alarm output
Available
Environment
Storage temperature
-10 °C to +70 °C
Operating temperature
-10 °C to +60 °C
Humidity (non condencing)
95%
IP rating
IP205
Remote signalling capabilities
KL731A
Analogue addressable optical sensor (with field exchangeable chamber)
E
E
E
E
E
E
KOB700
Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
E Full range: Ionisation, Optical and Heat and Duel
KZ700
KZ705
KZ705AS
KZ705IAS
KZ705I
Universal fire detector base
Universal fire detector base with earth connection
Analogue fire detector base with sounder
Analogue fire detector base with isolator and sounder
Analogue fire detector base with isolator
PA25/3L
Low current remote LED indicator
Radioactive source
NA
Dimensions (h x Ø)
45 mm x 99 mm
Ordering Information
Field exchangeable optical chamber
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
sensors (optical/heat)
E Full range of supporting I/O units and accessories
E EN54 Approved
E Black Colour
Addressable Fire Systems
Page : 61
KL731AB
Analogue addressable optical detector - Black
The KL700A Series uses a microprocessor for measurement and
communication. An enhanced protocol ensures the overall integrity
and error free operation of the fire system, without compromising
speed. All sensors are compatible with a standard base that makes
them easily interchangeable and that supports the connection of a
remote indicator. The KL731B is a black detector specificlly designed
for false ceilings.
Specifications
Operating voltage
22 - 38 VDC
Current consumption
Quiescent @ 38 VDC
350 A
In alarm
Less than 11 mA
Alarm indication (Dual LED)
Red
Remote alarm output
Available
Environment
Storage temperature
-10 °C to +70 °C
Operating temperature
-10 °C to +60 °C
Humidity (non condencing)
95%
IP rating
IP205
Radioactive source
NA
Dimensions (h x Ø)
45 mm x 99 mm
Ordering Information
KL731AB Analogue addressable optical detector - Black
KOB700
Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
E
E
E
E
E
E
Remote signalling capabilities
Field exchangeable optical chamber
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
E Full range: Ionisation, Optical and Heat and Duel
sensors (optical/heat)
E Full range of supporting I/O units and accessories
E EN54 Approved
E Black Colour
Addressable Fire Systems
Page : 62
KL735A
Analogue addressable dual (optical and thermal) sensor
The KL700A Series uses a microprocessor for measurement and
communication. An enhanced protocol ensures the overall integrity
and error free operation of the fire system, without compromising
speed. All sensors are compatible with a standard base that makes
them easily interchangeable and that supports the connection of a
remote indicator.
Specifications
Operating voltage
22 - 38 VDC
Current consumption
Quiescent @ 38 VDC
350 A
In alarm
Less than 5 mA
Alarm indication (Dual LED)
Red
Remote alarm output
Available
Environment
Storage temperature
-10 °C to +70 °C
Operating temperature
-10 °C to +70 °C
Humidity (non condencing)
95%
IP rating
IP42
Radioactive source
NA
Dimensions (h x Ø)
51 mm x 99 mm
Ordering Information
KL735A Analogue addressable dual (optical and thermal) sensor
E
E
E
E
E
E
Remote signalling capabilities
Fixed and Rate-of-Rise heat detectors
Easy soft addressing (1-125)
SMD technology
Reliable communication protocol
Full diagnostic self testing
E Full range: Ionisation, Optical and Heat and Duel
sensors (optical/heat)
E Full range of supporting I/O units and accessories
E EN54 Approved
Addressable Fire Systems
Page : 63
PG700
Fire sensor programmer
The PG700 is a handheld device programmer and tester for the
KL700A/Dx1500 series detectors. It is battery operated and allows the
installer to perform installation tasks (such as device addressing) and
maintenance tasks (such as device calibration) in the field without
external assistance.
Specifications
Supply
2 x 9 V batteries
Dimensions (w x h x d)
104 x 195 x 63 mm
Ordering Information
PG700 Fire sensor programmer
E Easy to use
E Battery operated
E 4 User selectable programs
-Device analogue value
-Change Device Address
-Sequential device addressing
-KL731A Calibration
Detector Bases & Accessories
Page : 64
Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
KOB700
The KOB700 is an optical replacement chamber for KL731/KL731A and
DP331I/DP1561 detectors. It is an inexpensive part that allows easy
maintenance of these detectors on site without the need for cleaning
solvents or complicated cleaning procedures. Once replaced, the
detector performs as if it was a new device.
Specifications
Dimensions (Ø x h)
65 x 19 mm
Ordering Information
KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
E
E
E
E
Inexpensive
Easy replacement
Reduces maintenance time
No additional tools required
KL7A
Dust Protector Cover for KL700/A and Dx300/1500 detectors
The KL7A is a dust protector cover for the KL700/DI322I and
KL731/DP331I conventional, as well as the KL700A/DP1552 and
KL731A/DP1561A addressable detectors. It allows for the protection of
the detector chamber against the ingress of dust from building
materials during construction or renovation of the building.
Ordering Information
KL7A Dust Protector Cover for KL700/A and Dx300/1500 detectors
E Negligible cost
E Easy to install and remove
E Avoids unnecessary contamination of the detector
during building works
Detector Bases & Accessories
Page : 65
KZ700
Universal fire detector base
The KZ700 is a 4 contact universal detector base. It has the ability to
compensate for uneven mounting surfaces. It is also available in black
for special applications in false ceilings.
Specifications
Dimensions
Diameter
104 mm
Height
24 mm
Ordering Information
KZ700 Universal fire detector base
KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black
E Polarity sensitive
E Universal base fits conventional and analogue
detectors
E
E
E
E
Compensates for uneven surfaces
Remote indicator contact available
EN54 approved
Variant in black also available
Detector Bases & Accessories
Page : 66
KZ700B
Universal fire detector base (for KL700/A and Dx300/1500) - Black
The KZ700B is a black 4 contact universal detecor base for use with the
KL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.
It has the ability to compensate for uneven mounting surfaces.
Specifications
Dimensions
Diameter
104 mm
Height
24 mm
Ordering Information
KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black
E Polarity sensitive
E Universal base fits conventional and analogue
detectors
E
E
E
E
Compensates for uneven surfaces
Remote indicator contact available
EN54 approved
Variant in black also available
Detector Bases & Accessories
Page : 67
KZ705
Universal fire detector base with earth connection
The KZ705 is a 5 contact universal detector base for use with the
KL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.
In addition to the normal base and remote indication connectors, the
KZ705 also has an additional earth terminal connector to allow for
easy terminations of a possible cable screen.
Specifications
Dimensions (Ø x h)
100 x 29 mm
Operating Voltage
-
Current Consumption
-
Isolation Current
-
Isolation Resistance
-
Sounder Frequency
-
Sound Output
@ 3 mA
-
@ 5 mA
-
Environmental Characteristics
Operating Temperature
-10 to 70 °C
Storage Temperature
-10 to 70 °C
Relative Humidity (max)
95 % (non-cond.)
Ordering Information
E Polarity sensitive
E Universal base fits conventional and analogue
detectors
KZ705 Universal fire detector base with earth connection
E Additional earth terminal available
E Remote indicator contact available
S700
Surface mount accessory for KZ700 and KZ705 series bases
The S700 is a base accessory designed for use with the KZ700 series
detector bases. It allows for a surface mount conduit and cable to
enter the base from the side. The KZ700 series base fits on top of this
accessory.
Specifications
Dimensions
Diameter
95 mm
Height
30 mm
Ordering Information
S700 Surface mount accessory for KZ700 and KZ705 series bases
E Surface mount accessory for KZ700 series bases
Addressable Fire Systems
Page : 68
KZ705I
Analogue fire detector base with isolator
The KZ705I is a detector base with built in isolator for use with the
KL700A/Dx1500 series detectors from GE-Interlogix. The isolator
protects the loop from short circuit conditions. A LED on the side of the
base indicates the status of the isolator.
Specifications
Dimensions (Ø x h)
100 x 29 mm
Operating Voltage
17 - 34 V
Current Consumption
50 A
Isolation Current
6 mA
Isolation Resistance
140 Mohm
Sounder Frequency
-
Sound Output
@ 3 mA
-
@ 5 mA
-
Environmental Characteristics
Operating Temperature
-10 °C to +70 °C
Storage Temperature
-10 °C to +70 °C
Relative Humidity (max)
95 % (non cond.)
Ordering Information
KZ705I Analogue fire detector base with isolator
E
E
E
E
E
Polarity sensitive
Universal base for analogue detectors
Additional earth terminal available
Remote indicator contact available
Built in isolator
Addressable Fire Systems
Page : 69
KZ705AS
Analogue fire detector base with sounder
The KZ705AS is a detector base with built in analogue addressable
sounder for use with the KL700A/Dx1500 series detectors from
GE-Interlogix. The sounder has its own address on the fire panel loop
and works independent of the detector. It is fully controlled from the
fire panel.
Specifications
Dimensions (Ø x h)
120 x 58 mm
Operating Voltage
22 - 38 V
Current Consumption
300 A Quiescent
Isolation Current
-
Isolation Resistance
-
Sounder Frequency
1 kHz (Continuous)
Sound Output
@ 3 mA
85 dBA
@ 5 mA
90 dBA
Environmental Characteristics
Operating Temperature
-10 °C to +70 °C
Storage Temperature
-10 °C to +70 °C
Relative Humidity (max)
95 % (non cond.)
IP Rating
IP21c
Ordering Information
KZ705AS Analogue fire detector base with sounder
E
E
E
E
E
E
E
Polarity sensitive
Universal base for analogue detectors
Additional earth terminal available
Remote indicator contact available
Built in sounder
Up to 90 dBA sound output
Low current consumption
Addressable Fire Systems
Page : 70
KZ705IAS
Analogue fire detector base with isolator and sounder
The KZ705IAS is a detector base with built in analogue addressable
sounder and isolator for use with the KL700A/Dx1500 series detectors
from GE-Interlogix. The sounder has its own address on the fire panel
loop and works independent of the detector. It is fully controlled from
the fire panel. The isolator protects the loop from short circuit
conditions.
Specifications
Dimensions (Ø x h)
120 x 58 mm
Operating Voltage
22 - 38 V
Current Consumption
350 A Quiescent
Isolation Current
6 mA
Isolation Resistance
140 Mohm
Sounder Frequency
1 kHz (Continuous)
Sound Output
@ 3 mA
85 dBA
@ 5 mA
90 dBA
Environmental Characteristics
Operating Temperature
-10 °C to +70 °C
Storage Temperature
-10 °C to +70 °C
Relative Humidity (max)
95 % (non cond.)
IP Rating
IP21c
Ordering Information
KZ705IAS Analogue fire detector base with isolator and sounder
E
E
E
E
E
E
E
E
Polarity sensitive
Universal base for analogue detectors
Additional earth terminal available
Remote indicator contact available
Built in sounder
Up to 90 dBA sound output
Low current consumption
Built in isolator
Conventional Fire Systems
Page : 71
KZ705D
Conventional fire detector base with diode
The KZ705D is a 5 contact universal detector base for use with the
KL700/Dx300 series detectors from GE-Interlogix. In addition to the
normal base and remote indication connectors, the KZ705D also has
an additional earth terminal connector to allow for easy terminations
of a possible cable screen. The built in diode is specifically targeted at
systems using active end-of-line devices.
Specifications
Dimensions (Ø x h)
100 x 29 mm
Operating Voltage
-
Current Consumption
-
Isolation Current
-
Isolation Resistance
-
Sounder Frequency
-
Sound Output
@ 3 mA
-
@ 5 mA
-
Environmental Characteristics
Operating Temperature
-10 to 70 °C
Storage Temperature
-10 to 70 °C
Relative Humidity (max)
95 % (non-cond.)
Ordering Information
KZ705D Conventional fire detector base with diode
E
E
E
E
E
Polarity sensitive
Universal base for conventional detectors
Additional earth terminal available
Remote indicator contact available
Built in diode for active end-of-line systems
KZ705R
Conventional 12 VDC fire detector base with relay
The KZ705R is a 5 contact detector base for use with the KL731/DP331I
detectors from GE-Interlogix. In addition to the normal base and
remote indication connectors, the KZ705R also has an additional earth
terminal connector to allow for easy terminations of a possible cable
screen. A built in 12 V relay makes it ideal for use on low voltage
intrusion systems.
Specifications
Dimensions (Ø x h)
100 x 29 mm
Operating Voltage
12 V ± 10%
Current Consumption
12 A
Isolation Current
-
Isolation Resistance
-
Sounder Frequency
-
Sound Output
@ 3 mA
-
@ 5 mA
-
Environmental Characteristics
Operating Temperature
-10 °C to +70 °C
Storage Temperature
-10 °C to +70 °C
Relative Humdity
95 % (non cond.)
Ordering Information
KZ705R Conventional 12 VDC fire detector base with relay
E
E
E
E
Polarity sensitive
12 V relay for 4 wire systems
Additional earth terminal available
Remote indicator contact available
Annunciators
Page : 72
PA25/3L
Low current remote LED indicator
The PA25 remote indicators have been designed for direct connection
to fire detectors (conventional and analogue), enabling luminous
indication outside the area where the detector is installed.
Specifications
Electrical Specifications
Supply Voltage (Analogue)
5 to 10 VDC
Current Consumption
2 to 79 mA
Supply Voltage (Conventional) 2 to 5 VDC
Current Consumption
6.5 to 61.5 mA
Mechanical Specifications
Size (w x h x d)
80 x 80 x 42 mm
Weight
10 g
Box material
A.B.S.
Colour
White
Environmental Specifications
Protection level
IP20
Working temperature
-10 to +60 °C
Storage temperature
-10 to +70 °C
Ordering Information
PA25/3L Low current remote LED indicator
E
E
E
E
E
E
E
E
E
Direct two-wire connection to detector
Large angle of visibility - lit up on four sides
Low current consumption
Flashing option
2 to 10 VDC power supply
High luminosity
Compatible with third party products
IP20 protection level
Modern and elegant design
E ABS plastic casing with ruby red polycarbonate
spy-hole
E Shock resistant
Addressable Fire Systems
Page : 73
KAL410
Conventional Zone Monitor Unit - 1 Zone
Allows the connection of one conventional zone to the analogue fire
system loop. This zone is constantly monitored. Up to 20 conventional
devices may be connected to this zone.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
90 A
Quiescent @ 35 V
105 A
Alarm
< 3 mA
Aux. supply (24 VDC)
quiescent
200 A + equip
Aux. supply (24 VDC) alarm
< 85 mA
End-of-line resistor
4.7 kohm
Relay contact rating
NA
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +70°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
117 x 80 x 44 mm
Ordering Information
KAL410 Conventional Zone Monitor Unit - 1 Zone
E
E
E
E
E
E
Easy numeric addressing
Continuous supervision of the conventional zones
Surface mount
Local alarm indication
Externally or loop powered
Aesthetically pleasing
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 74
KAL414C
Conventional Zone Monitor Unit - 4 Zones
Allows the connection of four conventional zones to the analogue fire
system loop. These zones are constantly monitored. Up to 20
conventional devices may be connected to any zone.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
< 5 mA
Aux. Supply (24V DC)
Quiescent
200 A + equip
Aux. Supply (24V DC) Alarm
< 360 mA
End-of-line resistor
4.7 kOhm
Relay contact rating
NA
Environmental
Storage temperature
-10 to +50°C
Operating temperature
-10 to +70°C
Relative humidity
(non-condensing)
0-95 %
Dimensions (l x w x h)
163 x 107 x 36 mm
Ordering Information
KAL414C Conventional Zone Monitor Unit - 4 Zones
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Easy numeric addressing
Continuous supervision of the conventional zones
Surface mount
Local alarm indication
Externally powered
Aesthetically pleasing
Part of a family of I/O modules consisting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Addressable Fire Systems
Page : 75
KAL426C
Extinguishing Control Module
The 400 Series modules consists of a complete range of interfaces
developed for input/output control in the KSA700/FP1500 analogue fire
systems from GE Interlogix. The KAL426 allows for the connection and
control of one extinguishing area to the addressable fire panel loop.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
210 A
Alarm
< 10 mA
Aux. supply (24 VDC)
quiescent
120 mA
Aux. supply (24 VDC) alarm
<1A
End-of-line resistor
4.7 kOhm
Relay contact rating
2½ A
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +70°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
163 x 107 x 36 mm
Ordering Information
KAL426C Extinguishing Control Module
E
E
E
E
E
Aesthetically pleasing
Easy numeric addressing
Externally powered
Supervised I/O
Surface mount
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 76
KAL430
Relay Module - 1 Relay
Provides for one potential free relay output for the fire system loop.
Each relay allows for COMMON, NORMALLY OPEN and NORMALLY
CLOSED contacts. The output may be used to activate ventilation
controls, warning signs, activation of other alarm devices etc. during
fire situations.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
70 A
Quiescent @ 35 V
100 A
Alarm
< 3.5 mA
Aux. 24 VDC quiescent
22 mA
Aux. 24 VDC alarm
< 50 mA
End-of-line resistor
NA
Relay contact rating
2½A @ 250 VAC
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +70°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
Ordering Information
KAL430 Relay Module - 1 Relay
117 x 80 x 44 mm
E
E
E
E
E
E
Easy numeric addressing
Externally or loop powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 77
KAL434C
Addressable Relay Module - 4 Relays
Provides for four potential free relay outputs for the fire system loop.
Each relay allows for COMMON, NORMALLY OPEN and NORMALLY
CLOSED contacts. The outputs may be used to activate ventilation
controls, warning signs, activation of other alarm devices etc. during
fire situations.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
10 mA
Aux. 24VDC Quiescent
100 A
Aux. 24VDC Alarm
10 mA
End-of-line resistor
NA
Relay contact rating
2½A @ 250 VAC
Environmental
Storage temperature
-10 to +50°C
Operating temperature
-10 to +70°C
Relative humidity (non-cond.) 0-95 %
Dimensions (l x w x h)
163 x 107 x 36 mm
Ordering Information
KAL434C Addressable Relay Module - 4 Relays
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Easy numeric addressing
Externally powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
Part of a family of I/O modules consiting of:
- Conventional Zone Monitors
- Digital Input Modules
- Extinguishing Control Modules
- Isolator Modules
- Manual Call Points
- Output Units
- Retention Units
- Supervised Output Units for sounder control
Addressable Fire Systems
Page : 78
KAL440
Supervised Relay Module
Allows for the supervision of a single, 24 Volt powered output contact
on the fire system loop. This unit may be used to control for e.g.
sounders in case of fire conditions, but may also be used to switch any
output considered crucial enough to have the cable integrity between
the unit and the switch point monitored.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
< 3.6 mA
Aux. 24 VDC quiescent
23 mA
Aux. 24 VDC alarm
23 mA + equip
End-of-line resistor
4.7 kohm
Relay contact rating
1¼ A @ 250 VAC
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +70°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
117 x 80 x 44 mm
Ordering Information
KAL440 Supervised Relay Module
E
E
E
E
E
E
Easy numeric addressing
Externally powered
Supervised 24 VDC Output
Surface mount
Aesthetically pleasing
Local status indication
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 79
KAL450
Addressable Manual Call Point
The 400 Series modules consists of a complete range of interfaces
developed for input/output control in the KSA700/FP1500 analogue fire
systems from GE Interlogix. The KAL450 is an addressable manual call
point for manual fire activation.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
90 A
Quiescent @ 35 V
120 A
Alarm
< 3.5 mA
Aux. supply (24 VDC)
quiescent
NA
Aux. supply (24 VDC) alarm
NA
End-of-line resistor
NA
Relay contact rating
NA
Environmental
Storage temperature
-10 °C to +70°C
Operating temperature
-10 °C to +50°C
Relative humidity
95 % (non condensing)
Ingress Protection
IP20
Dimensions (L x W x H)
87 x 87 x 20 mm
Weight
98 g
Ordering Information
KAL450
DM715
DM780
DM781
DM782
DM783
DM784
DM785
DM787
DM788
DM790
DM795
DM798
DM799
DM800
Addressable Manual Call Point
EN54 universal glass for manual call point
Terminal tray for MCP
GS card
Hinged transparent MCP protection cover
BZB black bezel
Test key
Spacer box, red
Surface mounting box with connectors, red
Surface mount box without connectors, red
Flush mount cradle with connectors
Flush mount cradle, connectors & forkgrips
Breakable seal for MCP
Terminal tray ETT/3 with bezel 3
Resettable element for MCP DM700/KAL450
E
E
E
E
E
E
Easy numeric addressing
Loop powered
Local test facility
Surface or flush mount
Aesthetically pleasing
Local status indication
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
E Wide range of accessories
Manual Call Points
Page : 80
DM715
EN54 universal glass for manual call point
The DM715 is a universal EN54 approved break glass for the DM700
series and KAL450 manual call points.
Ordering Information
DM715 EN54 universal glass for manual call point
DM800 Resettable element for MCP DM700/KAL450
E
E
E
E
Plastic coated to prevent operator injury
No glass fragments on breaking
No hammer required
Approved EN54 part 11
DM782
Hinged transparent MCP protection cover
The DM782 anti-tamper plastic cover is a protection cover for the
DM700 and KAL450 manual call points. It prevents accidental
activation of the alarm by enforcing a two step action i.e. lifting the
cover, then activating the alarm.
Ordering Information
DM782 Hinged transparent MCP protection cover
DM798 Breakable seal for MCP
E Unobtrusive
E Transparent
E Protects from accidental alarm activation
Manual Call Points
Page : 81
DM787
Surface mounting box with connectors, red
The DM787 is surface mounting back-box for DM700 series and
KAL450 series manual call points. The DM787 is red and has 3 wiring
terminals
Specifications
Material
Self-extinguishing Noryl SE100
Colour
Red - RAL N°3020
Operating temperature
-40° to +85°C
Relative humidity
max. 90% RV
Ordering Information
DM787
DM787Y
DM787B
DM787G
DM788
Surface mounting box with connectors, red
Surface mounting box with connectors, yellow
Surface mounting box with connectors, blue
Surface mounting box with connectors, green
Surface mount box without connectors, red
E Easy to install
E For flush mounting of manual call points
E Three terminals
Addressable Fire Systems
Page : 82
KAL460
Digital Input Module
Provides a remote input to the fire system loop. The input is constantly
monitored and its status communicated to the fire control panel. The
input may be activated by closing or opening a potential free contact,
depending on the module configuration.
This module may be used to monitor any contact by showing its status
through the fire control panel e.g. the monitoring of pressure
equipment and closure fire break doors.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
< 10 mA
Aux. 24 VDC quiescent
200 A
Aux. 24 VDC alarm
< 50 mA
End-of-line resistor
NA
Relay contact rating
NA
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +70°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
Ordering Information
KAL460 Digital Input Module
117 x 80 x 44 mm
E
E
E
E
E
E
Easy numeric addressing
Externally or loop powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 83
KAL470
Isolator Module
The 400 series modules consist of a complete range of interfaces
developed for input/output control in the KSA700/FP1500 analogue fire
systems from GE Interlogix. The KAL470 is an isolator module in this
series that isolates the faulty zone on a fire panel loop during short
circuit conditions. The KAL470 does not use an address on the loop.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
10 mA
Aux. supply (24 VDC)
quiescent
NA
Aux. supply (24 VDC) alarm
NA
End-of-line resistor
NA
Relay contact rating
NA
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +50°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
Ordering Information
KAL470 Isolator Module
75 x 45 x 28 mm
E
E
E
E
Requires no device address
Automatic reset
Local status indication
Surface mount
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 84
KAL490
Retention Module - 1 Input / 1 Output
Provides a remote input and a potential free voltage relay output to
the fire system loop. The input signal is constantly monitored and its
status displayed on the control panel, whilst the output is fail-to-safe.
Auxiliary supply monitoring is also included.
The module is used to for e.g. control and monitor doors such as fire
break doors. The relay provides the door activation and the input
monitors the door status.
Specifications
Supply voltage
22-38 VDC
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
10 mA
Aux. 24 VDC quiescent
200 A
Aux. 24 VDC alarm
< 50 mA
End-of-line resistor
NA
Relay contact rating
1A @ 30 VAC/VDC
Environmental
Storage temperature
-10 °C to +50°C
Operating temperature
-10 °C to +70°C
Relative humidity
95 % (non condensing)
Dimensions (L x W x H)
117 x 80 x 44 mm
Ordering Information
KAL490 Retention Module - 1 Input / 1 Output
E
E
E
E
E
E
Easy numeric addressing
Externally or loop powered
Normally open / normally closed operation for I/O
Surface mount
Aesthetically pleasing
Local status indication
E Part of family of I/O modules consisting of:
-Conventional Zone Monitors
-Digital Input Modules
-Extinguishing Control Modules
-Isolator Modules
-Manual Call Points
-Output Units
-Retention Units
-Supervised Output Units for sounder control
Addressable Fire Systems
Page : 85
SK07A
Addressable loop powered siren
The SK07A loop powered siren is designed for connection to and
control by the KSA700/FP1500 analogue fire detection systems from
GE-Interlogix. Communication is done digitally between the fire panel
and the sounder.
Specifications
Electrical
Supply Voltage
22 - 38 VDC
Quiescent current
300 A
Alarm current
6 mA
Maximum sound level
87 dBA
Mechanical
Dimensions
63 mm (h) x 93 mm Ø
Maximum cable size
2.5 mm²
Fastening Screws
2 x 30 mm
Environmental
Working temperature
-20 °C to +50 °C
Storage temperature
-20 °C to +70 °C
Relative humidity (maximum) 95 %
Protection Index
IP445
Ordering Information
SK07A Addressable loop powered siren
E
E
E
E
E
E
E
E
E
EN54 part 3 compliant
Up to 87 dBA sound output
Low current consumption
Low profile
IP445 protection level
Easy installation
Polarity sensitive
Rear and side cable entry possible
Low and easy maintenance
Annunciators
Page : 86
KR24B
Illuminated warning sign (No text) 24VDC
The KR24 is specifically designed as an evacuation warning sign for
gas extinguising areas. The KR24B has no text on the backlit display,
and text may therefor be added as required for the application. Units
supplied with text in various languages are also available.
Specifications
Electrical Specifications
Supply Voltage
18 to 27 VDC
Activation Voltage
18 to 27 VDC
Current Consumption
600 mA
Switching Polarity
NA
Indicators
24 V 3 W
Environmental Specifications
Working Temperature
-10 to 75 °C
Physical Specifications
Number of zones
NA
Buzzer output
80 dB
Housing Colour
Grey
Display Colour
Red
Weight
700 g
Size (w x h x d)
255 x 110 x 50 mm
IP Rating
IP50
Ordering Information
KR24B Illuminated warning sign (No text) 24VDC
E
E
E
E
Low current consumption
Large angle of view
Optical and acoustic indications selectable
Modern and elegant design
Annunciators
Page : 87
KR24-ING
Illuminated extinguishing waring sign (English version) 24VDC
The KR24 is a backlit "No Entry / Extinguishing Release" warning sign to
be used with gas extinguishing areas. Warning text is available in
various languages.
Specifications
Electrical Specifications
Supply Voltage
18 to 27 VDC
Activation Voltage
18 to 27 VDC
Current Consumption
600 mA
Switching Polarity
NA
Indicators
24 V 3 W
Environmental Specifications
Working Temperature
-10 to 75 °C
Physical Specifications
Number of zones
NA
Buzzer output
80 dB
Housing Colour
Grey
Display Colour
Red
Weight
700 g
Size (w x h x d)
255 x 110 x 50 mm
IP Rating
IP50
Ordering Information
KR24-ING Illuminated extinguishing waring sign (English version) 24VDC
E
E
E
E
Low Consumption
Large angle of vision
Optical and acoustic indication selectable
Modern and elegant design
Annunciators
Page : 88
SK07
Low consumption multi-tone alarm siren
The SK07 multi-tone siren is designed to sound an acoustic alarm
inside buildings. This small, low profile siren combines a high sound
output with low power consumption. It complies with the requirements
of EN 54 part 3.
Specifications
Electrical
Supply Voltage
22 - 26 VDC
Alarm current
3 mA at 85 dBA or less than 20 mA at 95 dBA
Maximum sound level
95 dBA
Working temperature
-20 °C to 50 °C
Storage temperature
-20 °C to 70 °C
Maximum relative humidity
95 % (non condencing)
Mechanical
Dimensions
63 mm (h) x 93 mm Ø
Protection Index
IP445
Fastening screws
2 x 30 mm
Maximum cable section
2.5 mm²
Recommended cable size
Single core 1.5 mm²
Ordering Information
SK07 Low consumption multi-tone alarm siren
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Low profile
Easy installation
Back and side cable entry
Polarity sensitive
Connection base included
Input and output terminals included
Acoustic power output selection
Up to 95 dBA sound output
Eight different alarm tones
Automatic tone change
Low current consumption
Low maintenance
IP445 protection level
EN54 part 3 compliant
Addressable Fire Systems
Page : 89
PCC-Config
KSA701/FP1500 Configuration software kit
PCC-Config allows easy, menu driven, programming of all the features
and settings of the panel. Common texts can be easily copied to
sensors and zones. Programming becomes simple as all settings are
displayed for the programmers convenience.
Specifications
Hardware requirements
Communication
RS232, modem and/or TCP/IP
Display
VGA or higher resolution
Hard disk
2 Gb with 650 Mb free space
Keyboard
Required
Pointing device
Required
Printer
System printer required for printing
Processor
133 MHz or higher Pentium-compatible CPU
RAM
64 Mb or more
Removable media
1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system
Win '98, Win 2000, Win XP
Ordering Information
PCC-Config KSA701/FP1500 Configuration software kit
KSP700
KSA702/5 Configuration software kit
E Windows based
E Complete external configuration of the installation
E Configuration possibilities for single and networked fire
systems
E Local or remote operation via modem or TCP/IP
E Standard RS232 communication
Addressable Fire Systems
Page : 90
Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
PCG-Graphic102
The PCG-Config series consists of 3 software applications. The
individual software formats allows the graphic package to grow with
the installation. PCG-Config102 operates with a single panel and allows
for the configuration of all devices up to a maximum of two loops.
Specifications
Hardware requirements
Communication
RS232, modem and/or TCP/IP
Display
SVGA or higher resolution
Hard disk
2 Gb with 650 Mb free space
Keyboard
Required
Pointing device
Required
Printer
System printer required for printing
Processor
1 GHz or higher Pentium III-compatible CPU
RAM
256 Mb or more
Removable media
1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system
Windows '98 or Windows 2000
Ordering Information
E Bi-directional communication with single panels and
networked fire systems
PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
E
E
E
E
E
E
E
E
E
Local or remote connection via modem or TCP/IP
Large selection of user configurable icons
Visualises device alarms and status of in- and outputs
Event texts retrieval from the panel
Configurator and operator contol levels
Navigation buttons allowed
Event logs with reporting facilities
Basic drawing package included
Imports bmp & drw format graphics
Addressable Fire Systems
Page : 91
Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
PCG-Graphic105
The PCG-Config series consists of 3 software applications. The
individual software formats allows the graphic package to grow with
the installation. PCG-Config105 supports a single panel up to 5 loops.
Specifications
Hardware requirements
Communication
RS232, modem and/or TCP/IP
Display
SVGA or higher resolution
Hard disk
2 Gb with 650 Mb free space
Keyboard
Required
Pointing device
Required
Printer
System printer required for printing
Processor
1 GHz or higher Pentium III-compatible CPU
RAM
256 Mb or more
Removable media
1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system
Windows '98 or Windows 2000
Ordering Information
PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
E Bi-directional communication with single panels and
networked fire systems
E
E
E
E
E
E
E
E
E
Local or remote connection via modem or TCP/IP
Large selection of user configurable icons
Visualises device alarms and status of in- and outputs
Event texts retrieval from the panel
Configurator and operator contol levels
Navigation buttons allowed
Event logs with reporting facilities
Basic drawing package included
Imports bmp & drw format graphics
Addressable Fire Systems
Page : 92
PCG-GraphicNW
Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)
The PCG-Config series consists of 3 software applications. The
individual software formats allows the graphic package to grow with
the installation. PCG-ConfigNW allows for monitoring on networked
systems with multiple panels.
Specifications
Hardware requirements
Communication
RS232, modem and/or TCP/IP
Display
SVGA or higher resolution
Hard disk
2 Gb with 650 Mb free space
Keyboard
Required
Pointing device
Required
Printer
System printer required for printing
Processor
1 GHz or higher Pentium III-compatible CPU
RAM
256 Mb or more
Removable media
1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system
Windows '98 or Windows 2000
Ordering Information
E Bi-directional communication with single panels and
networked fire systems
PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)
E
E
E
E
E
E
E
E
E
Local or remote connection via modem or TCP/IP
Large selection of user configurable icons
Visualises device alarms and status of in- and outputs
Event texts retrieval from the panel
Configurator and operator contol levels
Navigation buttons allowed
Event logs with reporting facilities
Basic drawing package included
Imports bmp & drw format graphics
Addressable Fire Systems
Page : 93
KSP700
KSA702/5 Configuration software kit
The KSP700 provides for a interface for the Kilsen KSA702 and KSA705
analogue addressable fire panels for the up/downloading of the fire
panel configuration software from a PC. It is supplied as a kit, including
the configuration cable together with PCC-Config, the software
configuration program for these panels.
Specifications
Hardware requirements
Communication
RS232, modem and/or TCP/IP
Display
VGA or higher resolution
Hard disk
2 Gb with 650 Mb free space
Keyboard
Required
Pointing device
Required
Printer
System printer required for printing
Processor
133 MHz or higher Pentium-compatible CPU
RAM
64 Mb or more
Removable media
1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system
Win '98, Win 2000, Win XP
Ordering Information
KSP700 KSA702/5 Configuration software kit
E Windows based
E Complete external configuration of the installation
E Configuration possibilities for single and networked fire
systems
E Local or remote operation via modem or TCP/IP
E Communications interface included
Addressable Fire Systems
Page : 94
KSP701
PC Configuration RS232 Cable for KSA701/FP1500 fire panels
The KSP701 is a RS232 cable for connecting the KSA701 Series or
FP1500 Series fire panels to an industry standard RS232 port on any
PC. It is normaly included with all software applications for these
panels, but may also be ordered seperately when required.
Ordering Information
KSP701 PC Configuration RS232 Cable for KSA701/FP1500 fire panels
E Complete RS232 cable with connectors
Addressable Fire Systems
Page : 95
PCC2000
Programming and configuration software
PCC2000 allows easy, menu driven, programming of all the panel's
features and settings. Common texts can be easily copied while
sensors, zones and areas increment or follow automatically. Boolean
logic programming becomes simple as inputs and outputs are
continuously displayed for the programmer's convenience.
Specifications
Processor
486 66 MHz
RAM
12 Mb
Display adapter
VGA
Hard disk space
20 MB
Pointing device
MS Mouse
Graphical environment
Windows 98, 2000, XP
Communications ports
1 x RS232
1 x Parallel
Ordering Information
PCC2000 Programming and configuration software
E Provide communication with single fire panels and
networked fire systems, both locally or remote via
modem
E
E
E
E
Windows 98, 2000 and XP compatible
For use with 2000/1200 series panels
Menu driven
Full or partial up- and download
Addressable Fire Systems
Page : 96
PCG-N
Graphics package network application with copy protection key
2 Packages allow the graphic package to grow with the installation.
The basic version PCG-S operates with a single panel, while the PCG-N
supports a network. Upgrades do not require rework on the existing
database, drawings, etc.
Specifications
Processor
Pentium II 266 MHz (or better)
RAM
64 Mb (or more)
Display adapter
SVGA or better
Hard disk space
200 MB
Pointing device
MS Mouse, Bus or P/S2
Graphical environment
Windows NT
Communication ports
1 x RS-232 - Depending on drivers
1 x Parallel - Printer port (for key)
Ordering Information
PCG-N Graphics package network application with copy protection key
E Provide bi-directional communication with single fire
panels and networked fire systems, both locally and
remote via modem
E
E
E
E
E
E
E
E
E
E
E
E
Windows 2000 and NT compatible
For use with FP2000, FP1200, FP1100 and FP700
Constructed around Sybase SQL Anywhere
Large selection of icons
Visualises inputs & outputs
Information page per point
Get texts from panel
Several operator levels and passwords
Operator configurable
Multiple navigation buttons
Event logs
Basic drawing package included
E Imports .bmp & .wmf drawings from virtually any
package
E Hardware key protected
Addressable Fire Systems
Page : 97
PCG-S
Graphics package with copy protection key
2 Packages allow the graphic package to grow with the installation.
The basic version PCG-S operates with a single panel, while the PCG-N
supports a network. Upgrades do not require rework on the existing
database, drawings, etc.
Specifications
Item
Recommended
Processor
Pentium II 266 MHz (or better)
RAM
64 Mb (or more)
Display adapter
SVGA or better
Hard disk space
200 MB
Pointing device
MS Mouse, Bus or P/S2
Graphical environment
Windows NT
Communication ports
1 x RS-232 - Depending on drivers
1 x Parallel - Printer port (for key)
Ordering Information
PCG-S Graphics package with copy protection key
E Provide bi-directional communication with single fire
panels and networked fire systems, both locally and
remote via modem
E
E
E
E
E
E
E
E
E
E
E
E
Windows 2000 and NT compatible
For use with FP2000, FP1200, FP1100 and FP700
Constructed around Sybase SQL Anywhere
Large selection of icons
Visualises inputs & outputs
Information page per point
Get texts from panel
Several operator levels and passwords
Operator configurable
Multiple navigation buttons
Event logs
Basic drawing package included
E Imports .bmp & .wmf drawings from virtually any
package
E Hardware key protected
Addressable Fire Systems
Page : 98
PCM2000
Maintenance and support software with copy protection key
PCM2000 allows local and remote maintenance facilities for 1200/2000
series fire panels. Amongst others, it allows for full panel emulation,
data retrieval and central alarm monitoring.
Specifications
Processor
Pentium 133Mhz (or better)
RAM
32 Mb (or more)
Display Adapter
VGA
Hard Disk Space
20 MB
Pointing Device
Bus or P/S2 Mouse
Graphical Environment
Windows 98, NT or 2000
Communications ports
Depending on Drivers Printer port (for key)
1 Parallel
Ordering Information
PCM2000 Maintenance and support software with copy protection key
E Provide communication with single fire panels and
networked fire systems, both locally or remote via
modem
E
E
E
E
E
E
E
E
Windows 95, 98 and NT compatible
For use with FP2000, FP1200
Full panel emulation
Data retrieval
Central station
History log
Address book
Dynamic Link Library (DLL) for third party integration
Special Temperature Detectors
Page : 99
ST801
High Temperature Thermal Probe with 2 wire connection
The ST801 thermal probe high temperature heat detector is designed
to protect from hazards where high temperatures are produced at a
specific point. The sensitive element (bulb) can be set at a distance of
up to 1 meter from the connection box. The ST801 may be connected
via 2 wires directly to a conventional fire panel zone.
Specifications
Suppy Voltage
24 VDC
Current Consumption
Quiescent
Ø
Alarm
100 mA
Alarm Monitoring
Two wires to conventional zone
Capilliary pipe length
1m
Probe Dimentions (l x Ø)
150 x 3 mm
Dimensions
140 x 100 x 70 mm
Colour
Grey RAL7032
Working Temperature
50 °C to 300 °C
Weight
0.8 kg
Ordering Information
ST801 High Temperature Thermal Probe with 2 wire connection
E Completely metal
E Adjustable from 50 to 300 °C
E Back and side cable input
E Sensitive probe with 1 m of stainless steel capillary
piping
E
E
E
E
E
Resistant to heat, grease and humidity
Easy installation
Easy connection
Easy maintenance
Ideal for commercial areas
Special Temperature Detectors
Page : 100
ST802
High Temperature Thermal Probe with relay output
The ST802 thermal probe high temperature heat detector is designed
to protect from hazards where high temperatures are produced at a
specific point. The sensitive element (bulb) can be set at a distance of
up to 1 meter from the connection box. The ST802 provides a protential
free relay output for alarm indication with COM, NC and NO contacts.
Specifications
Suppy Voltage
24 VDC
Current Consumption
Quiescent
Ø
Alarm
100 mA
Alarm Monitoring
5A potential free relay
Capilliary pipe length
1m
Probe Dimentions (l x Ø)
150 x 3 mm
Dimensions
140 x 100 x 70 mm
Colour
Grey RAL7032
Working Temperature
50 °C to 300 °C
Weight
0.6 kg
Ordering Information
ST802 High Temperature Thermal Probe with relay output
E Completely metal
E Adjustable from 50 to 300 °C
E Back and side cable input
E Sensitive probe with 1 m of stainless steel capillary
piping
E
E
E
E
E
Resistant to heat, grease and humidity
Easy installation
Easy connection
Easy maintenance
Potenial free alarm relay output
Door Magnets
Page : 101
CR255
Electronic delay control for double-leaf fire doors
The CR255 is an electronic delay control unit for use with double-leaf
fire doors. It allows for the release of the one leaf of the fire door to be
slightly delayed to allow for the two leafs to close properly and in the
correct sequence.
Ordering Information
CR255 Electronic delay control for double-leaf fire doors
E Easy to install
E May be installed inside the door release magnet
housing
E 24 VDC operation
Content
NKB602
NKB604
NKB606
NK702
NK704
NK708
NK712
NK716
NK703
NK706
RB404
SB404
EOL-ACT
KLBlack-S
KLBlack-B
KSA701-1
KSA701-2
NC785
KSA701R
KSA701R-24
KSA705
KSA705P
KAL701
KAL732
KAL785
KAL791
KSA1204
KSA1208
KSA1264R
KSA12255R
LC1502
LON2000
LON2000R
NC2011
NC2051
NE2011
NE2051
PR2000
RB2016
ZE2064
FRL700
NA704
NC700
NC771
Conventional fire alarm panel with 2 zones
Page : 3
Conventional fire alarm panel with 4 zones
Page : 4
Conventional fire alarm panel with 6 zones
Page : 5
Conventional fire panel with 2 fire alarm zones
Page : 6
Conventional fire panel with 4 fire alarm zones
Page : 7
Conventional fire panel with 8 fire alarm zones
Page : 8
Conventional fire panel with 12 fire alarm zones
Page : 9
Conventional fire panel with 16 fire alarm zones
Page : 10
Conventional extinguishing control panel with 3 zones
Page : 11
Conventional extinguishing control panel with 6 zones
Page : 12
Relay module, 4 potential free relays for NK700/Fx400 fire panels
Page : 13
Relay module, 4 supervised relays for NK700/Fx400 fire panels
Page : 14
Active end-of-line device for use with FP400/KL700 fire panels
Page : 15
Black front panel cover (small footprint)
Page : 16
Black front panel cover (large footprint)
Page : 16
Analogue addressable fire detection panel - 1 loop
Page : 17
Analogue addressable fire detection panel - 2 loops
Page : 18
RS485 expansion kit for KSA701/FP1500 fire panels
Page : 19
KSA701 Series LCD Repeater (mains powered)
Page : 20
KSA701 Series LCD Repeater (24VDC powered)
Page : 21
Analogue addressable fire panel (expandable to 5 loops)
Page : 22
Analogue addressable fire panel with printer (expandable to 5 loops)
Page : 23
Loop driver module for KSA702/705 control panels
Page : 24
RS232 communications module for KSA702/5 control panels
Page : 24
RS485 communications module for KSA702/5 control panels
Page : 25
Protocol Converter RS232/485 - Kilsen / Johnsson Control
Page : 25
Analogue fire panel, 2 loops upgradable to 4, 64 display zones
Page : 26
Addressable fire panel, 2-8 loops, 64-255 display zones upgradable
Page : 27
Repeater / emulator with 64 zone indications
Page : 28
Global zone repeater, 64 zones expandable up to 255
Page : 29
2-loop extension board for 1200/2000 series fire panels
Page : 30
LON700 driver for FP1200 / FP2000
Page : 30
LON driver for FP1200/2000 - closed loop systems
Page : 31
ARCNET RS485 network card with single RS485 interface
Page : 31
ARCNET network card with single optical interface board
Page : 32
RS485 network extension board
Page : 32
Fibre optic network extension board
Page : 33
Internal printer
Page : 33
Relay extension board for 1200/2000 series fire panels
Page : 34
64-zone LED extension fire and fault LED
Page : 34
LCD repeater
Page : 35
LON700 network amplifier (4 way)
Page : 36
LON700 interface board
Page : 36
LON700 closed loop communication board (no driver)
Page : 37
NE771
OCB724
PS700
RB708
SIB716
SOB708
ZI708
KM260/1R3-03
KM260/3R3-03
KM260EXT3-03
KM260C
KM170
KZ400
S300
ASD20C
ASD20F
ASD20FIL
KV210
KV210P
KL500
KZ500
KL700
KL710
KL731
KL731B
KCT731
KL700A
KL710A
KL731A
KL731AB
KL735A
PG700
KOB700
KL7A
KZ700
KZ700B
KZ705
S700
KZ705I
KZ705AS
KZ705IAS
KZ705D
KZ705R
PA25/3L
LON700 driver for the NC771 and NA704
Page : 37
LON700 output board with 24 open collector outputs
Page : 38
Plug-in power supply 3.5 A
Page : 38
LON700 output board with 8 relays
Page : 39
Supervised input board 16 way LON700
Page : 39
LON700 output board with 8 supervised outputs
Page : 40
8 zone input extension board
Page : 40
CO detection control panel - 1 Zone (English Version)
Page : 41
CO detection control panel - 3 Zones (English Version)
Page : 42
CO detection expansion module (English Version)
Page : 43
Blanking plate for KM260 panels
Page : 44
CO detector with base and mounting supplement
Page : 45
Detector base for KL400/KM170 series devices
Page : 46
Surface mount supplement for KL300/KM170 detectors
Page : 46
Aspiration Smoke Detector
Page : 47
Filter housing for ASD20
Page : 48
Filter only for ASD20
Page : 48
Rate-of-Rise Heat Detector
Page : 49
Rate-of-Rise Heat Detectors with remote indicator output
Page : 50
Low Profile Ionisation Smoke Detector
Page : 51
Fire detector base for KL500 detectors
Page : 52
Ionisation detector, conventional
Page : 53
Temperature detector (fixed and rate-of-rise), conventional
Page : 54
Optical detector, conventional (with field exchangeable optical block)
Page : 55
Optical detector, conventional - Black
Page : 56
Calibration Tool for KL731/DP331I Fire Detectors
Page : 57
Analogue addressable ionisation sensor
Page : 58
Analogue addressable temperature sensor
Page : 59
Analogue addressable optical sensor (with field exchangeable chamber)
Page : 60
Analogue addressable optical detector - Black
Page : 61
Analogue addressable dual (optical and thermal) sensor
Page : 62
Fire sensor programmer
Page : 63
Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
Page : 64
Dust Protector Cover for KL700/A and Dx300/1500 detectors
Page : 64
Universal fire detector base
Page : 65
Universal fire detector base (for KL700/A and Dx300/1500) - Black
Page : 66
Universal fire detector base with earth connection
Page : 67
Surface mount accessory for KZ700 and KZ705 series bases
Page : 67
Analogue fire detector base with isolator
Page : 68
Analogue fire detector base with sounder
Page : 69
Analogue fire detector base with isolator and sounder
Page : 70
Conventional fire detector base with diode
Page : 71
Conventional 12 VDC fire detector base with relay
Page : 71
Low current remote LED indicator
Page : 72
KAL410
KAL414C
KAL426C
KAL430
KAL434C
KAL440
KAL450
DM715
DM782
DM787
KAL460
KAL470
KAL490
SK07A
KR24B
KR24-ING
SK07
PCC-Config
PCG-Graphic102
PCG-Graphic105
PCG-GraphicNW
KSP700
KSP701
PCC2000
PCG-N
PCG-S
PCM2000
ST801
ST802
CR255
Conventional Zone Monitor Unit - 1 Zone
Page : 73
Conventional Zone Monitor Unit - 4 Zones
Page : 74
Extinguishing Control Module
Page : 75
Relay Module - 1 Relay
Page : 76
Addressable Relay Module - 4 Relays
Page : 77
Supervised Relay Module
Page : 78
Addressable Manual Call Point
Page : 79
EN54 universal glass for manual call point
Page : 80
Hinged transparent MCP protection cover
Page : 80
Surface mounting box with connectors, red
Page : 81
Digital Input Module
Page : 82
Isolator Module
Page : 83
Retention Module - 1 Input / 1 Output
Page : 84
Addressable loop powered siren
Page : 85
Illuminated warning sign (No text) 24VDC
Page : 86
Illuminated extinguishing waring sign (English version) 24VDC
Page : 87
Low consumption multi-tone alarm siren
Page : 88
KSA701/FP1500 Configuration software kit
Page : 89
Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
Page : 90
Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
Page : 91
Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)
Page : 92
KSA702/5 Configuration software kit
Page : 93
PC Configuration RS232 Cable for KSA701/FP1500 fire panels
Page : 94
Programming and configuration software
Page : 95
Graphics package network application with copy protection key
Page : 96
Graphics package with copy protection key
Page : 97
Maintenance and support software with copy protection key
Page : 98
High Temperature Thermal Probe with 2 wire connection
Page : 99
High Temperature Thermal Probe with relay output
Page : 100
Electronic delay control for double-leaf fire doors
Page : 101
www.gesecurity.net
IPSCAT-2005-12-6 16:09:40
As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product
specifications, visit GE Security online or contact your GE Security sales representative.