1500 VDC TRACTION SYSTEM Technical data 1500 VDC Traction system cafpower.com Overall Operaition Voltage Range DC: 1000 V – 1800 V Converter Unit Layout R_brake (1) L_Filter R_brake (2) CONVERTER BOX Vcatenary (+) R_precharge R_perm_discharge FC PRD DC Return (+) 2/5 Power Core Technical data 1500 VDC Traction system cafpower.com Traction converter (EN-50207) FEATURE VALUE Technology IGBT 3300V – 1200A Maximum power 900kW (1 x 900 kW) Rated power 600kW (1 x 600 kW) Rated Input current 400 A (1 x 400 A) Rated voltage 1500VDC Operating voltage range (EN50163) 1000 Vdc – 1800 VDC Degree of protection (IEC60529) IP66 Refrigeration system Natural (heat pipe) Electrical Braking Regenerative/Rheostatic * Mounting Under frame mounting Noise (ISO 3095) < 67 dB Smoke / Gas emissions UIC 895 OR / CEI 1034 Fire standard NF F16-101/102 Weight 600 kg * Depending on the catenary absorption capability. 3/5 Technical data 1500 VDC Traction system cafpower.com Train configuration Motor car / cabin Motor car without cabin Trailer car (optional) Motor car without cabin N Car R Car N Car M Car Semiunit Semiunit CAR M EJ2 CAR N EJ3 EJ4 EJ1 EJ2 INV MOTOR2 MOTOR1 4/5 M Car Semiunit Connection to the semiunit (M-N) EJ1 Motor car / cabin EJ3 EJ4 INV MOTOR4 MOTOR3 MOTOR2 MOTOR1 MOTOR4 MOTOR3 Technical data 1500 VDC Traction system cafpower.com Train performance - MNRNM Train performance (traction) Rated power 500 Kw Maximum power (constant power range, 40-45km/h) 769,8 Kw Maximum speed 80 km/h Maximum traction range 0 a 40 km/h Maximum acceleration (constant strenght range) 1,0 m/s2 (4M1T) Maximum initial strength 69,28 KN Maximum initial strength (maximal adherence) 78,8 KN Braking performance Service braking maximum deceleration 1,2 m/s2 Constant braking range 0 a 50 km/h Emergency deceleration 1,3 m/s2 Fading speed 5 km/h 5/5 Parque Tecnológico de San Sebastián Pso. Mikeletegi, 58 - 2º 20009 San Sebastián · SPAIN T +34 943 309 251 F +34 943 309 252 cafpower.com