Uploaded by Zaki Anwer

BOQ

advertisement
Building No. 2Electrical Works - Page No. 1
CONSTRUCTION OF SBP NEW OFFICE BUILDING COMPLEX AT D. I. KHAN
2. Building 2 - Mechanical Works
Cost of Taxes
Prime Cost
Item No.
Brief Description of Item
Qty
Unit
Unit Rates
(Material
+
Services)
Amount (Rs.)
A
Cost Impact
Applicable Rates as per Contract
Time duration for Earnest Money (Months.)
M 2.1
M 2.2
M 2.3
BUILDING-2 (OFFICE BUILDING)
A. LIFTS WORKS: MATERIAL
Passenger Lifts (L-2A & L-2B)
Ref. Specification No. 8530 & 9000
Supply of brand new Passenger Lifts having capacity
of 1000 kg / 13 persons. Speed 1.0 m/s Mschine
Room Type, VVVF drive, 02 stops / 02 openings, total
travel 4.9m. The lift shall be complete in all respect
including car, hoisting, machine, counter weight,
support brackets, embedded parts, access ladder,
separator screen, trap door etc. as per specification
and drawing.
2
Nos.
specifications and drawings.
a) 3/4 inch dia.
b) 1/2 inch dia.
90
10
Feet
Feet
a) 1/2 inch dia.
4
Nos.
B. GAS PIPING WORKS: MATERIAL
Refer Specification Section No. 8460
(Entire under mentioned work will be executed by
SSGC or their approved Contractors)
Supply of Galvanized Steel Pipes, medium grade
conforming to BS 1387 with all fittings sockets,
bends, tees, elbows, where required) fixed to walls,
ceilings and floors etc. including caps and plugs as per
Providing Ball Valves in gas piping network as per
specifications and drawings of following diameter:
GST/PST
I/T
Contractor's
Profit
Contractor's
Overheads
16.00%
of K
7.50%
of K
10.00%
of A
15.00%
of A
B
16%
C
7.50%
H
10%
I
15%
Total Estimated Cost
at the End of Project
(Rs.)
K
Building No. 2Electrical Works - Page No. 2
M 2.4
C. VAULT DOORS (VD): MATERIAL
Ref. Specification No. 8582 & 9000
Supply of single leaf vault door conforming to EN
1143-1:2012 Standard Grade XI and having 03 Nos
Class C High Security Locks or 2 Nos Class D High
Security Locks conforming to EN 1300:2018
Standard along with grille gate & lock. The door shall
be equipped with user friendly handle, light to use,
burglary resistant, noise reducing and durable,
comprising UL Listed hardwares, including the cost
of civil and electrical works and any other necessary
works required, complete in all respects and as
directed by the Engineer In-charge and as per
specification and drawings.
a) VD 4'-0" x 8'-6" / 1220 X 2100mm (W x H)
M 2.5
M 2.6
M 2.7
1
Nos.
Ref. Specification No. 8583 & 9000
Supply of single leaf vault doors conforming to
manufacturer standard. The door shall be equipped
with user friendly handle, light to use, burglary
resistant, noise reducing and durable, comprising
hardwares, including the cost of civil and electrical
works and any other necessary works required,
complete in all respects and as directed by the
Engineer In-charge and as per specification and
drawings.
a) LVD 4'-0" x 8'-6" / 1220 x 2100 mm (W x H)
6
Nos.
E. VAULT DOORS IN A/C DUCTS
Ref. Specification No. 8583 & 9000
Supply of single leaf Vault Doors inside AirConditioning Ducts conforming to manufacturer
standars. The door shall be equipped with user
friendly handle, light to use, burglary resistant, noise
reducing and durable, comprising UL Listed
hardwares, including the cost of civil and electrical
works and any other necessary works required,
complete in all respects and as directed by the
Engineer In-charge having following dimensions and
as per specification and drawings:
a) DVD1 in A/c Duct 2'-8" x 1'-6" (W x H)
At Grid (C, D) - (5, 6), Basement Building-2
1
Nos.
b) DVD2 in A/c Duct 2'-6" x 1'-10" (W x H)
At Grid (C, D) - (5, 6), Basement Building-2
1
Nos.
c) DVD3 in A/c Duct 2'-2" x 1'-8" (W x H)
At Grid (F, G) - (5, 6), Basement Building-2
2
Nos.
d) DVD4 in A/c Duct 1'-8" x 1'-6" (W x H)
At Grid (A, B) - (2, 3), Basement Building-2
1
Nos.
e) DVD5 in A/c Duct 1'-6" x 1'-2" (W x H)
At Grid (E, F) - (2, 3), Basement Building-2
1
Nos.
f) DVD6 in A/c Duct 1'-2" x 1'-0" (W x H)
At Grid (E,F) - (1), Basement Building-2
2
Nos.
g) DVD7 in A/c Duct 1'-2" x 0'-10" (W x H)
At Grid (F, G) - (2), Basement Building-2
4
Nos.
2
Nos.
D. LOCAL VAULT DOORS (LVD): MATERIAL
F. LIFTS WORKS: SERVICES
Passenger Lifts (L-2A & L-2B)
Ref. Specification No. 8530 & 9000
Installation,
testing
&
commissioning
and
maintenance (during defect liability period) of brand
new Passenger Lifts having capacity of 1000 kg / 13
persons. Speed 1.0 m/s Mschine Room Type, VVVF
drive, 02 stops / 02 openings, total travel 4.9m. The
lift shall be complete in all respect including car,
hoisting, machine, counter weight, support brackets,
embedded parts, access ladder, separator screen,
trap door etc. as per specification and drawing.
G. GAS PIPING WORKS: SERVICES
Refer Specification Section No. 8460
(Entire under mentioned work will be executed by
SSGC or their approved Contractors)
Building No. 2Electrical Works - Page No. 3
M 2.8
Installation, testing & commissioning of Galvanized
Steel Pipes, medium grade conforming to BS 1387
with all fittings sockets, bends, tees, elbows, where
required) fixed to walls, ceilings and floors etc.
including caps and plugs as per specifications and
M 2.9
M 2.10
M 2.11
M 2.12
drawings.
a) 3/4 inch dia.
b) 1/2 inch dia.
90
10
Feet
Feet
specifications and drawings of following diameter:
a) 1/2 inch dia.
4
Nos.
a) VD 4'-0" x 8'-6" / 1220 X 2100mm (W x H)
1
Nos.
Ref. Specification No. 8583 & 9000
Supply of single leaf vault doors conforming to
manufacturer standard. The door shall be equipped
with user friendly handle, light to use, burglary
resistant, noise reducing and durable, comprising
hardwares, including the cost of civil and electrical
works and any other necessary works required,
complete in all respects and as directed by the
Engineer In-charge and as per specification and
drawings.
a) LVD 4'-0" x 8'-6" / 1220 x 2100 mm (W x H)
6
Nos.
E. VAULT DOORS IN A/C DUCTS: SERVICES
Ref. Specification No. 8583 & 9000
Supply of single leaf Vault Doors inside AirConditioning Ducts conforming to manufacturer
standars. The door shall be equipped with user
friendly handle, light to use, burglary resistant, noise
reducing and durable, comprising UL Listed
hardwares, including the cost of civil and electrical
works and any other necessary works required,
complete in all respects and as directed by the
Engineer In-charge having following dimensions and
as per specification and drawings:
a) DVD1 in A/c Duct 2'-8" x 1'-6" (W x H)
At Grid (C, D) - (5, 6), Basement Building-2
1
Nos.
b) DVD2 in A/c Duct 2'-6" x 1'-10" (W x H)
At Grid (C, D) - (5, 6), Basement Building-2
1
Nos.
c) DVD3 in A/c Duct 2'-2" x 1'-8" (W x H)
At Grid (F, G) - (5, 6), Basement Building-2
2
Nos.
d) DVD4 in A/c Duct 1'-8" x 1'-6" (W x H)
At Grid (A, B) - (2, 3), Basement Building-2
1
Nos.
e) DVD5 in A/c Duct 1'-6" x 1'-2" (W x H)
At Grid (E, F) - (2, 3), Basement Building-2
1
Nos.
f) DVD6 in A/c Duct 1'-2" x 1'-0" (W x H)
At Grid (E,F) - (1), Basement Building-2
2
Nos.
g) DVD7 in A/c Duct 1'-2" x 0'-10" (W x H)
At Grid (F, G) - (2), Basement Building-2
4
Nos.
Fixing Ball Valves in gas piping network as per
C. VAULT DOORS (VD): SERVICES
Ref. Specification No. 8582 & 9000
Supply of single leaf vault door conforming to EN
1143-1:2012 Standard Grade XI and having 03 Nos
Class C High Security Locks or 2 Nos Class D High
Security Locks conforming to EN 1300:2018
Standard along with grille gate & lock. The door shall
be equipped with user friendly handle, light to use,
burglary resistant, noise reducing and durable,
comprising UL Listed hardwares, including the cost
of civil and electrical works and any other necessary
works required, complete in all respects and as
directed by the Engineer In-charge and as per
specification and drawings.
D. LOCAL VAULT DOORS (LVD): SERVICES
Total Mechanical Portion
Grand Total Mechanical Works =