Front view Side view W max. 11783 4202 General view W 10000 4350 H max. 5445 4115 8 ,9 2989 891 H 3000 891 4441 1126 n8 Combined Sun, Rain and Heat Exchanger Roof 10 500 1000 D 3150 690 693 339 420 1600 5757 1600 690 1510 3490 1423 350 D max. 6510 10200 10800 Concrete foundation (customers scope of supply) General view Fall protection Top view 47 Ladder External Light Expansion vessel Lifting angle 26 13 48 27 20 Empty weight: approx 11.000 kg ING AIL EV PR Shelter door with panic bar 2100 x 1000 W IN D 11° TRUE PLANT NORTH General Design Specification: 1. Maximum Outside Day Temperature: +54 °C 2. Maximum Night Temperature after the Hottest Day: +29 °C 3. Internal Desired Temperature in PCS: +35°C 4. Heat Dissipation inside the shelter: 965 Watts (Equipment Room + Battery Room = 765 Watts + 200 Watts) 5. Colour: Pure white, RAL 9010 6. Material: meets class B2 to DIN 4102 7. Shelter Protection: IP54 8. Wall thickness of PCS: 85mm Stairs 14 40° EPC CONTRACTOR: NOTES: Status: INTERTEC-Hess GmbH Raffineriestraße 8 D-93333 Neustadt / Donau Pho.: +49(0)9445/9532-0 Rev. 0: Drawing created Rev. 1: Positions of the doors and arrangement of interior changed Rev. A: Length of shelter reduced to 9000mm and arrangement of interior changed Rev. B: Changes according to comments on Rev. A (Bore holes, Recesses added), adapted Shelter dimensions and arrangement of equipment in Shelter according to customer requirements Order 1:85 Date Name designed by 13.02.2017 Siebenhaar checked by 15.11.2016 Spiegel www.intertec.info EPC WORK FOR HP CONNECTION TO NGV FILLING STATION (PHASE-2A) Article-No.: A1613622 - Pos.10 Edition Modifikation Date Name VENDOR: Scale: This drawing is the property of INTERTECB 01.02.17 Hess GmbH. It shall not be copied or submitted to outside parties without our written A 19.01.17 consent. REV DATE All dimension tolerances are according to ISO 2768-medium unless otherwise specified. ISSUED FOR COMMENTS / APPOVAL ISSUED FOR COMMENTS / APPOVAL DESCRIPTION REVISIONS GS RS RS GS RS RS DRN CHK´D APP´D GENERAL ARRANGEMENT & LAYOUT DRAWING 13529202 1 : 85 5292 - VDR-5292-PL-GEN-1670-040 2/6 B 16 47 26 15 14 34 33 38 27 48 15 32 26 16 14 38 31 49 24 24 35 22 44 51 25 9 11 28 29 41 19 46 23 50 35 21 4 36 18 21 17 23 5 39 44 30 28 40 48 7 37 47 27 11 45 46 50 43 12 42 45 3 11 28 8 2 39 Battery Room Equipment Room Power loss: 200W Power loss: 765W 6 40 1 Part List (Customers part) Description Item-No. Panel TAG-Number Dimension 800(W) x 800(D) x 2100(H) 1 208-FGP-101 F&G Panel 800(W) x 800(D) x 2100(H) 208-XUY-101 RTU Panel 2 800(W) x 800(D) x 2100(H) 3 208-TEC-101 Telecom Panel 350(W) x 125(D) x 225(H) 4 208-HSSD-101 HSSD Panel Solar System Panel 852(W) x 350(D) x 1056(H) 5 208-SSSC-001 Solar System DCDB 800(W) x 300(D) x 1000(H) 6 208-SSDB-001 Battery Rack 1200(W) x 930(D) x 1650(H) 7 208-SSBB-001 Battery MCCB Box 800(W) x 300(D) x 1000(H) 8 208-SSBCB-001 Part List (Intertec part) Description Item-No. Water Buffer, Stainless steel 9 External Heat Exchanger, Stainless 10 steel Internal Heat Exchanger, Stainless 11 steel 12 Relief Valve 13 Ladder 14 Stairs 15 Door Closer 16 Panic Bar Electrical Distribution 17 Folding Desk 18 19 4 Liter Water Canister 20 Shelter Identification Plate Rubber Trampling Mat 21 Eye Wash Kit - Non Heated 22 Safety Signs 23 First Aid Kit 24 Level / Pressure Gauge 25 External Lights Ex 2x18W 26 27 Sounder Eaton Light 36 Watt Non-Ex Light for 28 Equipment room Light Switch Non Ex 29 Light 36 Watt Ex Light for Battery room 30 Light Switch Ex 31 Door open Alarm Non Ex 32 Door open Alarm Ex 33 34 24 V DC Socket Fire Extinguisher 35 DC~AC Converter STECA TS 1200-24 36 307(H)x222(W)x104(D) Hydrogen Detector System for Battery 37 Room Ex 38 Manual Call Point Eaton Ex Smoke Detector Tyco Ex 39 Heat Detector – Tyco Ex 40 Earthing copper bar for: Safety Earth; 41 Instrument Earth;InstrumentIS Temperature Transmitter Non Ex 42 Temperature Transmitter Ex No´s 43 1 44 MCT - G6x1 Frame from Roxtec Cable Tray GRP 1 45 1 46 Ex-Vent 1 47 Beacon Red 2 48 Beacon Blue Earthing copper bar for Battery room 1 49 Weather protection cover for Ex-Vent 3 50 Hydrogen Transmitter 1 51 EPC CONTRACTOR: NOTES: Status: INTERTEC-Hess GmbH Raffineriestraße 8 D-93333 Neustadt / Donau Pho.: +49(0)9445/9532-0 Rev. 0: Drawing created Rev. 1: Positions of the doors and arrangement of interior changed Rev. A: Length of shelter reduced to 9000mm and arrangement of interior changed Rev. B: Changes according to comments on Rev. A (Bore holes, Recesses added), adapted Shelter dimensions and arrangement of equipment in Shelter according to customer requirements 1:40 Date Name designed by 13.02.2017 Siebenhaar checked by 15.11.2016 Spiegel A1613622 - Pos.10 Modifikation Date Name 2 1 1 2 2 2 1 1 1 1 2 1 2 2 1 2 2 3 1 1 1 1 1 1 2 1 2 2 3 2 3 1 1 10 2 2 2 2 1 2 2 VENDOR: EPC WORK FOR HP CONNECTION TO NGV FILLING STATION (PHASE-2A) Article-No.: Edition 1 Scale: Order www.intertec.info No´s 1 This drawing is the property of INTERTECB 01.02.17 Hess GmbH. It shall not be copied or submitted to outside parties without our written A 19.01.17 consent. REV DATE All dimension tolerances are according to ISO 2768-medium unless otherwise specified. ISSUED FOR COMMENTS / APPOVAL ISSUED FOR COMMENTS / APPOVAL DESCRIPTION REVISIONS GS RS RS GS RS RS DRN CHK´D APP´D GENERAL ARRANGEMENT & LAYOUT DRAWING 13529202 1 : 40 5292 - VDR-5292-PL-GEN-1670-040 3/6 B