INCOMING QUALITY ASSURANCE (All SOLAN UNITS) SAMPLING PLAN (IQA-001) REVISION SUMMARY Rev. No. Revision details Doc. No. Issue No. Issue Date Rev. No. Revision Date Sheet : IQA-001 :1 : 06.06.98 : 05 : 22.11.2016 : 1 of 6 Rev. Date Reviewed by Approved by - RKU RBS 00 First Issue 01 Haripur plant added 01.02. 2006 SJG SDH 02 Sampling plan revised 01.04.2008 MDR SDH 03 Criteria for normal /relaxed sampling added 01.06.2008 MDR SDH 04 Logo changed & modification done 01.04.2013 SJG MDR 05 Amendment done in sampling plan to add sampling Inspection rule and added sampling for Hardware. 22.11.2016 SJG MDR . Reviewed by : Approved by : Incharge (IQA) HOD (QA) INCOMING QUALITY ASSURANCE (All SOLAN UNITS) SAMPLING PLAN (IQA-001) Doc. No. Issue No. Issue Date Rev. No. Revision Date Sheet : IQA-001 :1 : 06.06.98 : 05 : 22.11.2016 : 2 of 6 SAMPLING PLAN SCOPE:This plan indicates the number of units of product from each lot which are to be inspected (Sample size or series of sample sizes) and the associated criteria for determining the acceptability of the lot ( acceptance and rejection numbers) . FIELD OF APPLICATION:This sampling plan is followed by Incoming Quality Assurance (IQA) for inspection & testing of incoming raw material. Normal/ Tightened Inspection: 1) Follow Normal Inspection in case if supply is coming first time or regular supply without any defect. 2) Follow Tightened Inspection in case if two out of five or less consecutive lot have been non- acceptable in normal inspection. Reduced Inspection/Inspection Waiver: Follow reduced sampling inspection or waiver inspection if material is regular supply & ten successive lots of previous supply are passed without any defect (In case of waiver, no inspection is required and clear the lot based on past 10 supplies found ok) RESPONSIBILITY:In charge (IQA) is responsible for maintaining and control of this procedure. Following sampling plan shall be followed for Incoming Raw Material Inspection Reviewed by : Approved by : Incharge (IQA) HOD (QA) INCOMING QUALITY ASSURANCE (All SOLAN UNITS) SAMPLING PLAN (IQA-001) Doc. No. Issue No. Issue Date Rev. No. Revision Date Sheet : IQA-001 :1 : 06.06.98 : 05 : 22.11.2016 : 3 of 6 ABBREVATION:FIP – Forward Integrated Product MRI- Meter Reading Instrument PCB –Printed circuit Board Sampling plan (IQA-001) Scope : This plan indicates the number of units of product from each lot which are to be inspected (Sample size or series of sample sizes) and the associated criteria for determining the acceptability of the lot (acceptance and rejection numbers) . Guidelines for sample size (Normal and Tightened Inspection) Electricals, Electronics, Switches Relays, MRI’s, Consumables, Metallic parts, Plastics parts, Decals, Packing material & Manuals All sub Assemblies Parts and All types of FIP boxes Wires, Cables sleeves, PCB, PCB’s sub assemblies (I) All Hardware & Similar (II) LOT SIZE Visual Electrical / Dimensional/ Functional Visual 2 TO 8 9 TO 15 16 to 25 26 TO 50 51 TO 90 91 TO 150 151 TO 280 281 TO 500 2 2 3 5 5 8 13 20 2 2 2 3 3 3 5 5 2 3 5 8 13 20 32 50 Reviewed by : Electrical / Dimensional/ Functional 2 2 2 3 3 3 5 5 (III) Visual 3 5 8 13 20 32 50 80 Electrical / Dimensional/ Functional 2 2 2 3 3 3 5 5 Approved by : Incharge (IQA) HOD (QA) INCOMING QUALITY ASSURANCE (All SOLAN UNITS) SAMPLING PLAN (IQA-001) 501 TO 1200 1201 TO 3200 3201 TO 10000 10001 TO 35000 35001 TO 150000 150001 TO 500000 500001 AND OVER 32 50 80 125 200 315 500 5 8 8 8 13 13 13 80 125 200 315 500 800 1250 Doc. No. Issue No. Issue Date Rev. No. Revision Date Sheet 5 8 8 8 13 13 13 : IQA-001 :1 : 06.06.98 : 05 : 22.11.2016 : 4 of 6 125 200 315 500 800 1250 2000 5 8 8 8 13 13 13 Sample Size for (Reduced Inspection)- Electricals, Electronics, Wires, Cables, sleeves, PCB, PCB’s sub assemblies, Switches Relays, MRI’s, Consumables, All sub Assemblies Parts and All types of FIP boxes Metallic parts, Plastics parts, Decals, Packing material & Manuals (I) All Hardware & Similar ( II ) LOT SIZE Visual Electrical / Dimensional/ Functional Visual 2 TO 8 9 TO 15 16 to 25 26 TO 50 51 TO 90 91 TO 150 151 TO 280 281 TO 500 501 TO 1200 1201 TO 3200 3201 TO 10000 10001 TO 35000 2 2 2 2 3 5 8 8 13 20 32 50 2 2 2 2 2 2 2 2 2 3 3 3 2 2 2 3 5 8 13 20 32 50 80 125 Reviewed by : Electrical / Dimensional/ Functional 2 2 2 2 2 2 2 2 2 3 3 3 (III) Visual 2 2 3 5 8 13 20 31 50 80 125 200 Electrical / Dimensional/ Functional 2 2 2 2 2 2 2 2 2 3 3 3 Approved by : Incharge (IQA) HOD (QA) INCOMING QUALITY ASSURANCE (All SOLAN UNITS) SAMPLING PLAN (IQA-001) 35001 TO 150000 150001 TO 500000 500001 AND OVER 80 125 200 5 5 5 200 315 500 Doc. No. Issue No. Issue Date Rev. No. Revision Date Sheet : IQA-001 :1 : 06.06.98 : 05 : 22.11.2016 : 5 of 6 5 5 5 315 500 800 5 5 5 Note: (I) Resistors , Capacitors , Diodes , Transistors , Soldering Materials , Wires & Cables , sleeves , gaskets, Fuse, PCB’s, all sub assembly, switched relays, all IC’s, Fuses , CT’s IPA , FLUX,Electromechanical, Mechanical parts, All types of FIP boxes , electricals,electronics & adhesive. (PCB’s will be initially sampled. If defects are within acceptable criteria the lot is accepted, else the lot is screened 100%) (II) Plastics part, Packing, TTB, Brass, copper, metallic parts, Decals, manuals and similar parts. (III) All Hardware & Similar. Sample selection:1. Unit in numbers and packed in boxes, bags or reels / rolls. Consider total no. of box as a lot size and randomly select the boxes as per sampling plan. Take out the total number of samples from these boxes (Randomly) for visual and dimensional inspection. 2. Unit in Volume (Liters, Kg, and Grams) and packed in drums, cans, Polybag, tubes etc. Consider total no. of packets as a lot quantity and select samples of packets as per sampling plan. Finally inspection has to be done on selected packets. 3. Unit in Length (Meter) and packed in reels/ rolls. Consider total no. of role as a lot quantity and select no. of samples out of this total lot. Inspect the material from each role, which is drawn by random sampling. Acceptance Table: - Normal Inspection as per AQL 0.4 No.of Samples 2 3 5 Acceptance 0 0 0 Rejection / 1 1 1 100 % Inspection 8 0 1 13 0 1 20 0 1 32 0 1 50 0 1 80 1 2 125 1 2 200 2 3 315 3 4 500 5 6 800 7 8 Acceptance Table: - Tightened Inspection as per AQL 0.4 Reviewed by : Approved by : Incharge (IQA) HOD (QA) 1250 10 11 INCOMING QUALITY ASSURANCE (All SOLAN UNITS) SAMPLING PLAN (IQA-001) No.of Samples Acceptance Rejection / 100 % Inspection 2 0 1 3 0 1 5 0 1 Doc. No. Issue No. Issue Date Rev. No. Revision Date Sheet : IQA-001 :1 : 06.06.98 : 05 : 22.11.2016 : 6 of 6 8 0 1 13 0 1 20 0 1 32 0 1 50 0 1 80 0 1 125 1 2 200 1 2 315 2 3 500 3 4 Acceptance Table: - Reduced Inspection as per AQL 0.4 2 3 5 8 No. of Samples Acceptance 0 0 0 0 Rejection / 100 % 1 1 1 1 Inspection 13 0 1 20 0 1 32 0 1 50 0 2 80 1 3 125 1 4 200 2 5 315 3 6 500 5 8 800 5 6 Dimension and Value Inspection Guidelines. : 1. Measure the critical dimensions and values as marked in drawing or stated in test procedure or as per defined in Inspection standard. 2. Record the data in IQA format QF/QA/IQA/003 where inspection is done at IQA end. 3. Part can also be accepted on supplier report where all critical parameter inspected and visual criteria inspection covered in supplier report. Sampling inspections Rules As Per IS 2500 PART 1 :1992 1. Normal to Tightened : When two out of five or less consecutive lot have been non –acceptable in normal inspection 2. Tightened to Normal : When five consecutive lot have been considered acceptable in tightened inspection 3. Normal to Reduced : When 10 or more than accepted in normal inspection & No problem reported from production line 4. Reduced to Normal : When lot rejected in reduced inspection or production delayed and irregular due to material quality Reviewed by : Approved by : Incharge (IQA) HOD (QA) 1250 8 9 800 7 10