TECHNICAL SELECTION DATA SRA230C / SRA230E SPLIT DUCTED UNIT 3 THREE PHASE SCROLL SINGLE STAGE LOUVRE AXIAL FAN UNIT FEATURES • • • • • • • • Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with R410A Refrigerant Integral Fan Coil Safety Tray Adaptive Demand Defrost AM24 (24-Hour Wall Controller Supplied as Standard) 20 m Data Cable Included SPECIFICATION SUMMARY OUTDOOR UNIT MODEL SRA230C INDOOR UNIT MODEL SRA230E TOTAL* 23.42 22.45 SENSIBLE CAPACITY (kW) *** 19.56 18.59 HEATING CAPACITY (kW) ^ 22.32 COOLING INPUT POWER (kW) ^^ CONTROL FEATURES • • • • • • • Auto, Heat & Cool Modes Auto/Continuous Indoor Fan Operation 3 Speed Indoor Fan Setting Hot Start Feature Manual Control Inputs 24-Hour ON/OFF Timer Home/Building Automation ON/OFF Capability • AM7 (7-Day Programmable Controller with 2 Events/Day) • Remote Temperature Sensors • Zone Kit for Control up to 8 Zones (See Control Section) • Secondary Wall Controller with Mimic Logic PLENUMS (Optional) • Supply Air Plenums are Available in a 2 way or 3 way Configuration (See Accessories Section for details of Spigots availability) • Return Air Plenums are Available with 2 x 450 mm Spigots UNIT COMPLIANCE 23.50 7.21 HEATING INPUT POWER (kW) ^^ 6.66 EER 3.25 3.11 COP 3.35 3.53 INDOOR AIRFLOW (l/s) - MIN. / NOMINAL / MAX. ^^^ 1020 / 1200 / 1380 OUTDOOR SOUND PRESS. LEVEL @ 3M dB(A) - LOW / HIGH OUTDOOR SOUND POWER LEVEL dB(A) -- LOW / HIGH POWER SUPPLY - OUTDOOR CONTROL OPTIONS NETT** COOLING CAPACITY (kW) *** 55.0 / 59.0 71.0 / 75.0 415V / 3Ph+N / 50Hz POWER SUPPLY - INDOOR 240V / 1 Ph / 50 Hz RATED LOAD AMPS -- OUTDOOR / INDOOR / TOTAL ** 11.7 / 3.9 / 15.6 FULL LOAD AMPS -- OUTDOOR / INDOOR / TOTAL ^^^^ 15.1 / 4.9 / 20.0 CIRCUIT BREAKER AND CABLE AMPS 25.0 APPROXIMATE STARTING AMPS 101.0 WEIGHT (kg) -- INDOOR / OUTDOOR * ** *** ^ ^^ ^^^ ^^^^ Note: 85.0 / 200.0 Based on unit rating excluding indoor fan kW. Measured and tested in accordance with AS/NZS 3823.1.2. At 270C DB / 190C WB entering air temperatures and 350C ambient. At 200C DB entering air temperature and 70C DB / 60C WB ambient. input power includes indoor fan kW. Max. - Min. airflow application range. Full Load Amps are based on compressor and fan motors’ maximum expected current. See Specifications sheet for cable size and circuit breaker size details. Use input power to estimate running cost. • MEPS / QLD MP4.1 / SA MEPS • Demand Response AS4755.3.1 R ® ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® SRA230C-0200 / SRA230E-0100 - P1 100927 23.42 kW 3 Phase 1 Stage CENTRIFUGAL FAN CAPACITY SELECTION DATA SRA230C / SRA230E COOLING PERFORMANCE AIR ENTERING OUTDOOR INDOOR WB - 0C DB - 0C 25 30 3 Phase 1 Stage 23.42 kW 35 40 45 50 TOTAL CAPACITY kW 16 17 18 19 20 21 22 16 17 18 19 20 21 22 16 17 18 19 20 21 22 16 17 18 19 20 21 22 16 17 18 19 20 21 22 16 17 18 19 20 21 22 23.72 24.26 24.93 25.64 26.32 27.05 27.87 22.02 23.34 23.92 24.59 25.26 25.95 26.73 21.01 22.19 22.79 23.42 24.04 24.70 25.42 19.87 19.88 21.54 22.11 22.65 23.30 23.99 18.64 18.65 20.16 20.71 21.21 21.84 22.46 18.64 18.65 18.65 19.19 19.62 20.19 20.76 20 21 22 15.61 14.22 12.83 11.40 9.97 16.95 15.57 14.18 12.78 11.36 9.90 15.16 13.79 12.38 10.97 9.54 16.49 15.12 13.74 12.35 10.92 9.48 14.65 13.29 11.89 10.50 9.06 16.00 14.62 13.24 11.85 10.44 9.00 14.11 12.74 11.36 9.94 8.51 15.25 14.07 12.70 11.31 9.89 8.48 13.51 12.16 10.77 9.38 7.96 14.67 13.49 12.14 10.75 9.33 7.91 12.87 11.53 10.16 8.77 7.35 14.02 12.86 11.50 10.12 8.73 7.32 18.08 16.93 15.53 14.15 12.71 11.29 9.85 17.62 16.46 15.09 13.70 12.29 10.87 9.42 17.11 15.96 14.59 13.22 11.81 10.39 8.95 16.54 15.40 14.06 12.67 11.28 9.85 8.40 15.93 14.65 13.46 12.09 10.71 9.29 7.86 15.26 14.01 12.83 11.47 10.09 8.69 7.27 TOTAL SENSIBLE CAPACITY - kW AT DB TEMPERATURE ONTO INDOOR COIL - 0C 23 24 25 26 27 19.36 18.05 16.88 15.49 14.10 12.68 11.22 18.89 17.60 16.42 15.06 13.67 12.23 10.81 18.39 17.10 15.93 14.56 13.17 11.76 10.34 17.80 16.52 15.39 14.01 12.62 11.21 9.79 17.18 15.90 14.63 13.44 12.06 10.66 9.26 16.47 15.26 13.99 12.81 11.45 10.05 8.63 20.58 19.35 18.23 16.82 15.43 14.03 12.60 20.13 18.89 17.54 16.38 15.01 13.59 12.19 19.57 18.36 17.06 15.90 14.51 13.11 11.70 18.97 17.79 16.49 15.34 13.97 12.57 11.18 18.27 17.17 15.89 14.76 13.40 12.02 10.60 17.45 16.48 15.24 13.97 12.77 11.40 10.00 28 29 30 22.93 21.79 20.53 19.20 18.05 16.65 23.88 22.94 21.77 20.49 19.13 17.98 24.05 22.97 21.73 20.45 19.32 24.08 22.96 21.71 20.36 22.42 21.33 20.08 18.78 17.61 16.22 22.45 21.32 20.04 18.72 17.54 23.46 22.50 21.29 20.00 18.64 23.57 22.49 21.23 19.93 20.77 19.59 18.31 17.17 15.78 14.39 21.70 20.78 19.56 18.27 17.13 15.74 21.88 20.80 19.52 18.20 17.06 21.94 20.77 19.50 18.16 22.92 21.95 20.73 19.43 20.13 19.01 17.74 16.43 15.24 13.87 20.18 19.00 17.71 16.58 15.20 21.18 20.20 18.95 17.67 16.52 21.28 20.19 18.92 17.62 21.35 20.15 18.88 18.32 17.16 15.88 14.73 13.35 11.97 18.38 17.15 15.85 14.69 13.32 19.45 18.38 17.10 15.81 14.64 19.51 18.35 17.07 15.77 20.43 19.55 18.31 17.05 20.60 19.55 18.30 17.55 16.48 15.23 14.09 12.73 11.36 17.64 16.48 15.20 14.04 12.69 17.68 16.45 15.17 14.01 18.70 17.66 16.43 15.15 18.79 17.65 16.39 18.84 17.63 21.79 20.61 19.32 18.15 16.77 15.37 13.96 21.28 20.14 18.84 17.71 16.35 14.94 13.54 20.72 19.61 18.33 17.01 15.85 14.45 13.06 19.95 19.01 17.77 16.46 15.30 13.92 12.52 22.82 21.80 20.57 19.24 18.08 16.71 15.32 22.21 21.33 20.11 18.79 17.65 16.29 14.90 HEATING PERFORMANCE HEATING CAPACITY - kW AT DB ENTERING INDOOR - 0C WB TEMP ON OD COIL- 0C -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 16 18 20 22 24 TH IH TH IH TH IH TH IH TH IH 14.58 15.45 16.39 17.35 18.35 19.43 20.45 21.55 22.71 23.95 25.32 26.71 28.15 29.65 31.23 14.00 14.68 15.40 15.96 16.34 17.10 18.61 21.55 22.71 23.95 25.32 26.71 28.15 29.65 31.23 14.47 15.33 16.28 17.22 18.21 19.28 20.29 21.38 22.52 23.74 25.10 26.46 27.89 29.37 30.91 13.89 14.57 15.30 15.84 16.21 16.96 18.47 21.38 22.52 23.74 25.10 26.46 27.89 29.37 30.91 14.42 15.26 16.15 17.10 18.07 19.13 20.12 21.19 22.32 23.59 24.88 26.21 27.61 29.07 30.60 13.84 14.50 15.18 15.73 16.08 16.83 18.31 21.19 22.32 23.59 24.88 26.21 27.61 29.07 30.60 14.33 15.16 16.04 16.96 17.94 18.97 19.96 21.01 22.12 23.38 24.64 25.95 27.34 28.78 30.28 13.75 14.40 15.08 15.61 15.97 16.70 18.16 21.01 22.12 23.38 24.64 25.95 27.34 28.78 30.28 14.25 15.07 15.93 16.84 17.80 18.82 19.78 20.83 21.98 23.16 24.41 25.71 27.07 28.49 29.97 13.68 14.31 14.97 15.50 15.84 16.56 18.00 20.83 21.98 23.16 24.41 25.71 27.07 28.49 29.97 AIRFLOW CORRECTION MULTIPLIER % VARIATION INDOOR AIRFLOW (l/s) TOTAL COOLING SENSIBLE COOLING HEATING FACTOR -15% 1020 0.972 0.919 0.991 -10% 1080 0.982 0.947 0.994 -5% 1140 0.991 0.973 0.997 NOMINAL 1200 1.00 1.00 1.00 +5% 1260 1.008 1.027 1.002 +10% 1320 1.014 1.053 1.004 +15% 1380 1.021 1.077 1.006 TH - Total Heating Capacity (kW). IH - Integrated Heating Capacity (kW) Includes defrost losses. NOTES: 1. No allowance has been made for the effect of indoor fan motor. 2. Selection tables are based on nominal airflows. Correction factors must be applied for selection away from these conditions. PIPE LENGTH CORRECTION MULTIPLIER COOLING HEATING 5m 1.000 1.000 10m 0.997 1.000 20m 0.990 1.000 30m 0.983 1.000 40m 0.975 1.000 50m 0.968 1.000 60m 0.961 1.000 Correction multipliers are based on horizontal pipe runs. R ® ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® SRA230C-0200 / SRA230E-0100 - P2 090914 DIMENSIONS AND FAN CURVE SRA230C / SRA230E 1685 O/A OUTDOOR UNIT SRA230C FAN FAN Refer Pipe Pipe Connection Connection Details Refer to Specifi Specifications on cations Sheet 685 O/A CONDENSER AIR INLET CONDENSER COIL CONDENSER AIR OUTLET 50 ELEC. ACCESS 2 x 25mm 50 GAS PIPE 22.2mm LIQUID PIPE 12.7mm CONDENSER AIR INLET 1125 O/A 1025 670 80 1190 50 666 118 110 555.5 NOTES: 1. OPTIONAL ANTI-CORROSIVE ACRYLIC COATED COIL AVAILABLE ON ALL UNITS. 2. DO NOT SCALE DRAWING. 120 EVAPORATOR COIL 645 EVAP FAN 338 Supply Duct Connection H x W = 380 x 715. Return Duct Connection H x W = 410 x 1190. Drain Connection 25mm ID. All Dimensions in mm. EVAP FAN 715 338 695 O/A 1470 O/A 40 35 605 50 25 ACCESS PANEL SUPPLY AIR SUPPLY AIR 485 O/A RETURN AIR ELEC. BOX 380 410 70 SAFETY TRAY DRAIN 25mm 1425 50 GAS PIPE 25.4mm CONDENSATE DRAIN 25mm INDOOR UNIT FAN CURVE LIQUID PIPE 12.7mm 350 EXTERNAL STATIC PRESSURE (Pa) 300 250 200 15 0 10 0 50 0 700 800 AIRFLOW (l/s) 900 10 0 0 110 0 12 0 0 13 0 0 14 0 0 15 0 0 16 0 0 APPLICATION RANGE R ® ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® SRA230C-0200 / SRA230E-0100 - P3 090623 23.42 kW INDOOR UNIT SRA230E 118 555.5 3 Phase 1 Stage 110 118 SOUND DATA SRA230C / SRA230E Outdoor Radiated Sound Power Level (SWL) Fan Speed Octave Band Centre Frequency (Hz), dB Sound Power Level dB(A) 125 250 500 1k 2k 4k 8k Low 71.0 72.2 70.7 67.6 66.8 62.7 55.4 49.7 High 75.0 76.5 74.2 71.8 69.5 67.9 62.6 56.4 Sound Power Level (SWL) Airflow Setting Airflow Li/s Nominal Sound Power Level dB(A) 125 250 500 1k 2k 4k 8k 77.5 75.4 76.1 75.1 72.6 69.1 65.1 60.1 1200 Octave Band Centre Frequency (Hz), dB OUTDOOR RADIATED INDOOR OUTLET SRA230C Sound Power Level SRA230E Sound Power Level 80.0 Octave Band Sound Power Level (dB) 80.0 Octave Band Sound Power Level (dB) 3 Phase 1 Stage 23.42 kW Indoor Outlet 70.0 60.0 50.0 70.0 60.0 50.0 Low Nominal High 40.0 40.0 125 250 500 1k 2k 4k 8k Octave Band Centre Frequency (Hz) 125 250 500 1k 2k 4k 8k Octave Band Centre Frequency (Hz) NOTES: 1. Radiated sound power levels are based on ISO 3743-2. 2. Outlet sound power levels are based on ISO 13347-2. R ® ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® SRA230C-0200 / SRA230E-0100 - P4 100302 SRA230C / SRA230E SPECIFICATIONS CONSTRUCTION COMPRESSOR CABINET (Indoor Unit) 0.5 - 1.2 mm Galvanized Steel NUMBER PER UNIT x TYPE 1 x Scroll (Hermetic) CABINET (Outdoor Unit) 1.2 mm ZA & Galvanized Steel FULL LOAD AMPS 13.5 SURFACE FINISH (Outdoor Unit) 65 μ Baked Polyester Powder Coat LOCKED ROTOR AMPS 101.0 STARTING METHOD D.O.L. (optional soft starter) INSULATION (Indoor Unit) TYPE 10 mm Foil Faced Polyethylene REFRIGERATION SYSTEM 12 mm Expanded Polystyrene REFRIGERANT TYPE R-410A EXPANSION CONTROL Direct Expansion Orifice ELECTRICAL OUTDOOR UNIT Power Supply - 50 Hz 415 Volts x 3 Phase + N Voltage Range (min - max) 400 V - 440 V FACTORY CHARGE (grams) 7900.0 PRE-CHARGE LENGTH (metres) 10.0 ADDITIONAL REF. CHARGE (gm/m) 100.0 Full Load Amps* 15.1 FILTER DRIER Rated Load Amps** 11.7 CONNECTION SIZE & TYPE 12.7 mm (1/2”) ODF Soldered Bi-Flow Approximate Starting Amps 101.0 FACTORY SUPPLIED / FITTED No IP Rating IP44 INDOOR UNIT Voltage Range (min - max) 220 V - 260 V Full Load Amps* 4.9 IP Rating IP20 OUTDOOR & INDOOR UNIT (TOTAL) Full Load Amps* - Phase 1 20.0 Full Load Amps* - Phase 2 & 3 13.2 & 13.9 Rated Load Amps** 15.6 INTERCONNECTING PIPE RUN MAX PIPE LENGTH (metres) 60.0 MAX. VERTICAL LENGTH (metres) 20.0 (Included in Max. Pipe Length) FIELD PIPE SIZES Liquid Pipe 12.7 mm (1/2”) Gas Pipe 25.4 mm (1”) PIPE CONNECTIONS Indoor IMPORTANT - The local electricity authority may require limits on starting current and voltage drop, please check prior to purchase. * Full Load Amps are based on Compressor and Fan Motor’s maximum expected current. Outdoor Liquid Pipe 12.7 mm (1/2”) Swaged to fit 12.7 mm (1/2”) field pipe Gas Pipe 25.4 mm (1”) To be swaged in field to fit 25.4 mm (1”) field pipe Liquid Pipe 12.7 mm (1/2”) Swaged to fit 12.7 mm (1/2”) field pipe Gas Pipe 22.2 mm (7/8”) Swaged to fit 25.4 mm (1”) field pipe ** Rated Load Amps are measured and tested in accordance with AS/NZS3823.1.2. CABLE SIZE & CIRCUIT BREAKER SIZE Suggested minimum cable size should be used as a guide only, refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details. Cable Size (main line) 4.0 mm2 (SUGGESTED MINIMUM) Cable Size (indoor to outdoor wire) 1.0 mm2 (SUGGESTED MINIMUM) Circuit Breaker Size 25.0 Amps OUTDOOR COIL CONNECTION TYPE Solder Insulate both gas and liquid pipes separately. PROTECTION DEVICES HIGH PRESSURE CUTOUT SWITCH Nonadjustable (Automatic Reset) LOW PRESSURE CUTOUT SWITCH Nonadjustable (Automatic Reset) TUBE TYPE FIN TYPE Copper - Rifle Bore Aluminium - Wave COMPRESSOR MOTOR TEMP. Internal Thermal Cut-Out INDOOR FAN OVERLOAD Internal Thermal Cut-Out FACE AREA (m sqr) 1.98 OUTDOOR FAN OVERLOAD Internal Thermal Cut-Out FIN SPACING (per m) 630 SUMP HEATER WATTS 30 W during Compressor Off Cycle ROWS --- OUTDOOR FAN ELECTRIC CONTROLS DEFROST METHOD Reverse Cycle NUMBER OF FANS x TYPE 2 x Axial DEFROST TYPE Adaptive Demand Defrost NUMBER OF BLADES PER FAN 5 CONTROL CIRCUIT BREAKER 16.0 Amps DIAMETER (mm) 500 CONTROL FIELD WIRING 2 Core 14 / 0.20 Screened Cable OUTPUT kW 0.19 MOTOR TYPE / DRIVE TYPE 6 Pole External Rotor / Direct FAN SPEED CONTROL 2 Speed via Capacitor The standard type outdoor fans fitted to this unit will only accept 5Pa of external static resistance. OPERATING RANGE It is essential that the unit is correctly sized for the application and operates within its recommended range of operating conditions as shown below. MODE INDOOR AIR INTAKE TEMPERATURE OUTDOOR AIR INTAKE TEMPERATURE Max. 29oC DB / 19oC WB 50oC DB Min. 20oC DB / 15oC WB RANGE INDOOR COIL TUBE TYPE FIN TYPE FACE ARE (m sqr) FIN SPACING (per m) ROWS Copper - Rifle Bore Aluminium - Louvre 0.56 DIAMETER / WIDTH (mm) Heating 590 --- INDOOR FAN NUMBER OF FANS x TYPE Cooling 1 x Twin Deck Centrifugal 240 x 180 OUTPUT kW / INPUT kW 0.75 / 0.97 MOTOR TYPE / DRIVE TYPE 3 Speed 4 Pole / Direct o 15oC DB o Max. 24 C DB 21 C DB / 16oC WB Min. 16oC DB -10oC DB IMPORTANT - For low ambient cooling use option S. Lower ambient available on request. Contact your nearest ActronAir office for more details. Low Ambient Cooling Option S On Request Max. 29oC DB / 19oC WB 50oC DB Min. 20oC DB / 15oC WB 5oC DB o o Max. 29 C DB / 19 C WB 50oC DB Min. 20oC DB / 15oC WB -5oC DB AIR FILTERS All return air including fresh air must have adequate filters supplied and fitted by the installing contractor. Filters must be located in accessible location between the return air grille and the unit.ActronAir ® does not supply or make any provisions for return air filter. ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® R ® SRA230C-0200 / SRA230E-0100 - P5 100927 23.42 kW 240 Volts x 1 Phase 3 Phase 1 Stage Power Supply - 50 Hz See Installation Section for complete Filter Drier specifications. GREY CONDENSER WIRING BROWN 8 uF RUN CAPACITOR GREY LOW SPD. CAPACITOR 30 uF SRA230C 30 uF SRA260C FIELD WIRING FOR M SERIES ONLY NC NO ZONE 2 NC NO ZONE 3 NC NO ZONE 4 OPTIONAL ZONE CARD (AMZ) NC NO ZONE 1 RLY SENSOR KEY POWER COM NEUT NEUT COM EARTH OPTIONAL SENSOR 2 POWER KEY SENSOR DO NOT CONNECT SCREEN AT WALL CONTROL OPTIONAL SENSOR 1 DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. BLUE ACT NEUT 240V OUTPUT SCRN CONDENSER FAN NEUT INDOOR BOARD (AMIB-P) 240V OUTPUT 240V OUTPUT HIGH WITH TRACE WIRE CONNECTED TO THE SCREEN / COMMON TERMINAL COM INTERNAL AUTO RESET OVERLOAD PROTECTION LOW SPEED CAP. BLACK SUMP HEATER CABLE MUST BE 2 CORE 14/0.20 SCREENED CABLE NEUT MID COM GREY INDOOR FAN SENSOR WIRING DATA 16 AMP CONTROL NEUT ACT HIGH NEUT NOTICE: CIRCUIT BREAKER AUX. 240V VOLT FAN EARTH INTERNAL AUTO RESET OVERLOAD PROTECTION OPTIONAL REMOTE ON/OFF SWITCH EARTH 8 uF RUN CAPACITOR HIGH 3 Phase 1 Stage COOL ONLY ON 15V NEUT GREY NEUT CAPACITOR INTERNAL AUTO RESET OVERLOAD PROTECTION BLUE NEUT NEUT 07/05/2009 SRA260C SRA230C COMPRESSOR C1 CONTACTOR C1 NEUT CONDENSER FAN 20K OHM RESISTOR ALL M SERIES CONTROLS AM24 & AM7 SET TO STANDARD NEUT USED FOR REMOTE ON/OFF OPERATION (WALL CONTROL USE ONLY) DATA COM/ SCREEN PWR A BROWN HP SWITCH STAGE-2 ON BOOST HEAT ON WALL CONTROL CONT. FAN SINGLE SPEED INDOOR FAN EARTH EXTRA LOW VOLTAGE ELECTRONIC WALL CONTROL ACT BLACK HP DUAL SPEED INDOOR FAN AUTO. FAN MANUAL INPUTS STANDARD DIP SWITCH SETTINGS ACT 23.42 kW NEUT CONDENSER CPU BOARD REV OUTDOOR COIL SENSOR KEY LP SWITCH COMP WD0519 REV. DATE DRAWING NUMBER REV. This drawing remains the intellectual property of Actron Engineering Pty Ltd. Reproduction, modification and/or distribution are prohibited without written consent. INTERNAL AUTO RESET OVERLOAD PROTECTION REVERSING VALVE HP ACT-D4 CONTROL SYSTEM WIRING DIAGRAM WITH M-SERIES INDOOR BOARD R COMP. CONTACTOR VARIATION G SRA230C OUTDOOR UNIT - HI STATIC TOP DISCHARGE FANS SRA230C-G 1685 O/A 685 O/A CONDENSER AIR INLET CONDENSER COIL 340 172 340 50 1115 O/A 670 110 118 555.5 118 555.5 118 110 CONDENSER AIR OUTLET 300 57.5 40 ELEC. ACCESS 2 x 25.4mm Cond. Duct Connection L x W = 2 x (300 x 340) All Dimensions in mm. GAS PIPE 28.6mm CONDENSER AIR INLET LIQUID PIPE 12.7mm 666 1025 50 NOTES: 1. OPTIONAL ANTI-CORROSIVE ACRYLIC COATED COIL AVAILABLE ON ALL UNITS. 2. REFER PIPE CONNECTION DETAILS ON SPECIFICATIONS SHEET. 3. DO NOT SCALE DRAWING. 4. ENSURE SUFFICIENT ACCESS IS AVAILABLE TO SERVICE FANS WHEN INSTALLING DUCTING ON AIR OUTLETS. R ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® SRA230C-G -0200 - P7 090623 23.42 kW 250 3 Phase 1 Stage CONDENSER AIR INLET VARIATION H SRA230C OUTDOOR UNIT - HORIZONTAL DISCHARGE FANS 5 Pa SRA230C-H CONDENSER AIR INLET CONDENSER COIL CONDENSER AIR INLET 735 O/A 3 Phase 1 Stage 23.42 kW 1685 O/A 435 395 50 FAN 365 1075 O/A 530 FAN 670 377.5 110 118 555.5 685 118 555.5 118 110 50 ELEC. ACCESS 2 x 25.4mm GAS PIPE 28.6mm CONDENSER AIR INLET LIQUID PIPE 12.7mm 666 CONDENSER AIR OUTLET 1025 50 NOTES: 1. OPTIONAL ANTI-CORROSIVE ACRYLIC COATED COIL AVAILABLE ON ALL UNITS. 2. REFER PIPE CONNECTION DETAILS ON SPECIFICATIONS SHEET. 3. DO NOT SCALE DRAWING. R ® ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® SRA230C-H -0200 - P8 090623 VARIATION SRA230E V UPRIGHT FAN COIL VERTICAL DISCHARGE 1435 O/A SRA230E-V LIQUID PIPE 12.7mm GAS PIPE 25.4mm Supply Duct Connection H x W = 380 x 715 Return Duct Opening Size H x W = 445 x 1205 Drain Connection 25mm ID. All Dimensions in mm. 485 O/A FAN INDOOR COIL 100 1205 715 330 SUPPLY AIR 70 330 40 35 380 70 525 1065 O/A 445 RETURN AIR 100 115 415 115 415 55 115 100 CONDENSATE DRAIN 25mm H UPRIGHT FAN COIL HORIZONTAL DISCHARGE 1435 O/A SRA230E-H LIQUID PIPE 12.7mm FAN GAS PIPE 25.4mm COIL 100 1205 330 Supply Duct Connection H x W = 380 x 715 Return Duct Opening Size H x W = 445 x 1205 Drain Connection 25mm ID. All Dimensions in mm. 525 O/A 70 715 485 330 40 35 FAN ELEC. BOX 380 525 SUPPLY AIR 1025 O/A 610 445 100 115 415 115 415 115 100 RETURN AIR 55 CONDENSATE DRAIN 25mm NOTES: 1. OPTIONAL ANTI-CORROSIVE ACRYLIC COATED COIL AVAILABLE ON ALL UNITS. 2. REFER PIPE CONNECTION DETAILS ON SPECIFICATIONS SHEET. 3. DO NOT SCALE DRAWING. ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Please check prior to purchase. ® R ® SRA230E-V/H -0100 - P9 090623 23.42 kW 3 Phase 1 Stage FAN ELEC. BOX