Uploaded by kin wow

Rack Gas Visual inspection Report (RG-USM-008)

advertisement
Inspection Report
Visual Inspection of Lifting Equipment
Inspection Number
SKL/20/L/OIPTHAI/2058 Rev.0
Inspection Date:
18.06.2020
Next Inspection:
17.12.2020 (Mubadala, Cpoc)
17.06.2021 (PTTEP, Chevron)
Project Reference No. PP228413/0E
Customer
:
Intended for :
Global NDT Inspection Co., Ltd. (For United Supply and Multitrade Co., Ltd)
United Supply and Multitrade Co., Ltd
Place of test :
Date of test :
United yard, Singhanakorn, Songkhla, Thailand.
18 June 2020
Item:
Description as follows
Equipment I.D No.
Dimensions (L x W x H)
Tare Weight
Nett Weight
MGW.
:
:
:
:
:
Rack Gas / RG-USM-008
126 x 126 x 195 cm.
0.50 MT.
2.50 MT.
3.00 MT.
Complete with Sling & Master Link
:
:
:
:
Wire Rope Sling Four Legs
S/N.: USM-08 (AD 3003)
Dia. 14.00 mm. x 220 cm.
SWL: 5.00 MT.
Complete with Shackles
:
:
:
Bolt Type Anchor Shackle
ID. No.: 08 A to 08 D
Dia. 5/8 In.
SWL.: 3.25 MT .
Note: - Require of MPI on pad eye at welds of Rack Gas / RG-USM-008 and MPI on wire rope
sling 4 legs for master quad assemblies at welds report attached with certificate.
- Recommend to user’s daily check for general corrosion at underneath structure before
departure to offshore.
Reference Specification:
GLND: Guideline for Marine Lifting Operations 0027/ND Rev.10 (22/06/2013)
PTTEP: General Instruction for PTTEP Lifting Equipment Integrity Inspection Procedure
Docs No. CMS-12089-PDR-401, Container Guideline Docs No. CMS-12089-GDL-402,
(Rev. No. 0-0, dated Dec.,2016)
CPOC: General Instructions for Lifting Equipment CPOC-DPO-B17-1GEN-OP-INSP-018 Rev. 0
(April 2011)
Chevron Offshore Thailand: Portable Lifting Equipment Operation Practices Version 1.3
(1 July,2016), Appendix 1-Version 1.4 (1 July 2016), Appendix 2- Version 1.3 (1 July., 2016)
Mubadala Petroleum: Inspection of Lifting Equipment Procedure (TH-POT-AI-QA-PRC-0132-R6),
(Dec., 2018)
Result(s) of Inspection
The above items are inspected and revealed no defects that would otherwise impair its continued use .
DNV-GL Oil & Gas (Thailand)
_______________________
Name
Wiwat Techocha
Inspector
This Report Certificate intended for the sole use of the person or company to whom it is address and no liability of any nature whatsoever shall
be assumed to any other party in respect of its contents
DNV GL (Thailand) Co., Ltd
349 SJ Infinite I Business Complex ,15th Floor, Room no. 1501-1502 Vibhawadee Rangsit Road, Chomphon, Chatuchak Bangkok 10900
Tel 66(0) 2115 9868 Fax 66(0) 2115 9867 E-mail : www.dnvgl.com
Page 1 of 1
Report no : 2020-MT-0808
GLOBAL NDT INSPECTION CO., LTD.
Rev :0
Page : 1 of 1
MAGNETIC PARITCLE EXAMINATION REPORT
Client :
United Supply and Multitrade Co., Ltd.
Location of Work :
Utai Seya Yard, Songkhla Thailand
Project Name : Lifting equipment inspection.
Examination Date:
June 18, 2020
OrderedBy :
Ref. Code/Standard :
AWS D1.1 Table 6.1/ASTM E-709
United Supply and Multitrade Co., Ltd.
TEST METHOD
Stat of Examination :
As Weld
Before Load Test
After Load Test
Before Hydro Test
Serface Preparation :
Brushing
Grinding
Machining
Other
Media and Applied Method :
Visible
Fluorescent
Wet
Dry
Continous
Residual
Circular
Longitudinal
Permanent Yoke
S/N:
Magnatization Technique :
AC Yoke
S/N: 11949
Calibration Block :
40 lb S/N :G-001
Light Indensity :
Daylight (> 1000 Lux)
After Hydro Test
4279
EQUIPMENT OF INSPECTION
Rack Gas
Description :
Serial Number :
RG-USM-008
Sling+Master link (1 set)
AD-3003
Shackle (4Ea)
08 A TO 08 D
EXAMINATION PICTURE
MPI on Weldment area of Padeyes and Master link around Weld joint and 4 Shackles Full Boby .
Accepted
Was found to be free of surface Defect at the time of inspection
Repair
Found Defect (Please see picture) kind of
Rejected
Other
No visible imperfection were found at the time of inspection
Inspection Results :
Comment :
Remark :
Next of Inspection :
6 Month
12 Month
N/A
6 Month
12 Month
N/A
6 Month
12 Month
N/A
INSPECTOR - ASNT LEVEL-II
Signature :
PTTEP / CHEVRON : June 17, 2021
MUBADALA / CPOC : December 17, 2020
CUSTOMER REQUIREMENT :
REVIEW BY
Signature :
CUSTOMER
Signature :
Name :
Sakka Wanpuy
Name :
Vitasrut Apipuntananun
Name :
Date :
June 18, 2020
Date :
June 18, 2020
Date :
The present Inspection has been carried out to the best of our knowledge and ability and our personability is Limited to the exercise of
due care this Certificate / Report is issued on the understanding That it does not relieve sellers from their contractual obligations
FM-OP-004
Download