Uploaded by Zul Fadli

Fire engine Access Requirements Measurements

advertisement
ACCESS REQUIREMENTS FOR TURNTABLE LADDER
Access Required for Appliances
Type of
vehicle
Min. Width of
access road (m)
Pumping
Turn Table
Ladder
Hydraulic
Platform
Min. Clearance
Height (m)
Turn Circle
Diameter (m)
Min of Gateways
etc (m)
Laden Weight
(tonnes)
3.70
3.70
16.80
3.10
15.00
3.70
3.70
21.50
3.10
20.00
3.70
4.50
21.50
3.10
29.00
10.06m
HARD STANDING GROUND
5.00m
4.88m
PAVEMENT
PAVEMENT
FACE OF BUILDING
ACCESS REQUIREMENTS FOR HYDRAULIC PLATFORM
Access Required for Appliances
Type of
vehicle
Min. Width of
access road (m)
Pumping
Turn Table
Ladder
Hydraulic
Platform
Min. Clearance
Height (m)
Turn Circle
Diameter (m)
Min of Gateways
etc (m)
Laden Weight
(tonnes)
3.70
3.70
16.80
3.10
15.00
3.70
3.70
21.50
3.10
20.00
3.70
4.50
21.50
3.10
29.00
FOR THE SWEEP OF THE BOOM
2.13m
HARD STANDING GROUND
6.00m
10.00m
PAVEMENT
PAVEMENT
FACE OF BUILDING
1.83m
Download