ANNEXURE – I SIGNAL CONDITIONERS (24VDC Power Supply) : Product Order Codes A B C1 C2 2D D E1 E2 E3 E4 3 F 1 G - H XXX Code extension (optional) Accuracy: I : 0.2% of FS J : 0.1% of FS No of outputs ( 1 / 2 / 3 / 4 ) P: 2kV Isolation 3 Port Isolation Optional Output Signal 4 Optional Output Signal 3 Optional Output Signal 2 Output Signal 1 Q : 4kV Isolation 1 : 0 - +1VDC 5 : 0- +5VDC 10 : 0 - +10VDC B1 : 0 - +/- 1VDC B5 : 0 - +/-5VDC B10 : 0 - ± 10VDC 42 : 4 - 20mADc 20 : 0 -+20mADC B20 : 0 - ± 20mADC B10 : 0 - ± 10mADC 1 : 0 – 1KHz (Square Wave) 5 : 0 – 5KHz (Square Wave) 10 : 0 – 10KHz (Square Wave) Input Signal : Refer table I for parameter (Optional) Output Signal 2 : To be added when 2 / 3 / 4 outputs are present V : Voltage I : Current F : Frequency Output Signal 1: V : Voltage I : Current Input Signal : V : DC Voltage I : DC Current Vac : AC Voltage Iac: AC Current R : Potentiometric / Resistance F : Frequency F : Frequency RTD:RTD PT-100 / 1000 TC : Thermocouple LCA: Load cell sensor I : Standard Enclosure µ3.0: ME Enclosure µ4.0: GB Enclosure Note: Position 4, 8, 9 and 10 are optional and are to be used only when more than one Output is present. Page 2 of 4 Technical File Number: CAN-TCF-01/18-19/R-01 TABLE - I DC Voltage Signal DC Current Signal 75 : 0 – 75mVDC 100 : 0 – 100mVDC B75 : 0 – +/-75 mVDC B100 : 0 – +/-100mVDC 1 : 0 – 1VDC 5 : 0 – 5VDC 10 : 0 – 10VDC B1 : 0 – +/-1VDC B5 : 0 – +/-5VDC B10 : 0 – +/- 10VDC 1 5 7.5 10 20 42 B1 B5 B7.5 B10 B20 AC Voltage Signal ( RMS 50/60Hz) AC Current Signal ( RMS 50/60Hz) 50 : 0 – 50VAC 100 : 0 – 100VAC 100 : 0 – 100VAC 150 : 0 150VAC 300 : 0 – 300VAC 500 : 0 – 500VAC : 0 – 1 mADC : 0 – 5mADC : 0 – 7.5mADC : 0 – 10mADC : 0 – 20mADC : 4 – 20mADC : 0 – +/-1 mADC : 0 – +/-5mADC : 0 – +/-7.5mADC : 0 - +/-10mADC : 0 - +/- 20mADC 1 : 0 - 1AAC 5 : 0 – 5AAC 10 : 0 – 10AAC Potentiometric / Resistance Signal Frequency ( Square Wave) Signal 1K : 0 – 1K Ohm 5K : 0 – 5K Ohm 10K : 0 – 10K Ohm 1 : 0 – 1KHz 5 : 0 – 5KHz 10 : 0 – 10KHz 20 : 0 – 20KHz 100 : 0 – 100KHz RTD PT-100 / PT -1000 Signal Thermocouple Signal RTD PT-100 X : Measurement Temperature Range e.g. -100+100 for range of -100C to +100C XJ : Type J ( - 210 – +1200 Deg C)* XK : Type K ( - 270 – +1372 Deg C)* XE : Type E (- 270 – +1000 Deg C)* XB : Type B ( 0 – +1820 Deg C)* XR : Type R ( - 50 – +1768 Deg C)* XS : Type S ( - 50 – +1768 Deg C) * XT : Type T ( - 270 - +400 Deg C)* XN : Type N ( -270 - +1300 Deg C)* * Max. Temperature Range : - 200 – +850 Deg C * RTD PT-1000 X : Measurement Temperature Range e.g. -20+150 for range of -20C to +150C * Max. Temperature Range : - 50 – +200 Deg C * X : Measurement Temperature Range * : Max. Temperature Range Load Cell Sensor Signal 10 B10 16 B16 20 B20 30 B30 : 0 – 10mVDC : 0 – ±10mVDC : 0 – 16mVDC : 0 - ±16mVDC : 0 – 20mVDC : 0 - ±20mVDC : 0 – 30mVDC : 0 - ±30mVDC Page 3 of 4 Technical File Number: CAN-TCF-01/18-19/R-01 e.g. The product order code for the following specifications is as follows, 1. Input Output Number of Outputs Isolation Accuracy Supply Enclosure Product Code 2. Input Output 1 Output 2 Number of Outputs Isolation Accuracy Supply Enclosure Product Code 3. Input Range Output 1 Output 2 Number of Outputs Isolation Accuracy Supply Enclosure Product Code 4. Input Output 1 Output 2 Number of Outputs Isolation Accuracy Supply Enclosure Product Code Page 4 of 4 : 0 - +/-10VDC : 0 - +/-10VDC : 1 nos. : 3 Port, 2KV : 0.2% of Full Scale Output : 24VDC : Standard Enclosure : I VV 2D B10B10 3P 11I : 4 - 20mADC : 4 - 20mADC : 0 - +10VDC : 2 nos. : 3 Port, 2KV : 0.2% of Full Scale Output : 24VDC : Standard Enclosure : I IIV 2D 424210 3P 12I : RTD PT-100 : 0 – 250C : 4 - 20mADC : 4-20mADC : 2 nos. : 3 Port, 2KV : 0.2% of Full Scale Output : 24VDC : Standard Enclosure : I RTDII 2D 2504242 3P 12I : Loadcell ( 0 – +10mVDC) : 4 - 20mADC : 4-20mADC : 2 nos. : 3 Port, 2KV : 0.2% of Full Scale Output : 24VDC : Standard Enclosure : I LCAII 2D 104242 3P 12I Technical File Number: CAN-TCF-01/18-19/R-01