Uploaded by stojkov.goran

ONXCBL.004.000.021 Release Notes

advertisement
OneExpert CATV Software Release Notes
ONX-610 / ONX-620 / ONX-630
Version 4.0.21
Jul 24, 2020
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Table of Contents
OneExpert CATV Software Release Notes ..................................................................................................... 1
Table of Contents ............................................................................................................................................. 2
Release Management 4.0.11 ............................................................................................................................ 3
Release Management 4.0.15 ............................................................................................................................ 3
Release Management 4.0.18 ............................................................................................................................ 4
Release Management 4.0.21 ............................................................................................................................ 4
Significant Feature Enhancements Added in 4.0.11 ........................................................................................ 5
Significant Feature Enhancements Added in 4.0.21 ........................................................................................ 7
Significant Bugs Fixed in 4.0.11 ..................................................................................................................... 8
Significant Bugs Fixed in 4.0.15 ................................................................................................................... 12
Significant Bugs Fixed in 4.0.18 ................................................................................................................... 12
Significant Bugs Fixed in 4.0.21 ................................................................................................................... 13
Known Limitations ........................................................................................................................................ 14
Channel Plan Build Limitations .......................................................................................................... 14
StrataSync Limitations ......................................................................................................................... 14
Options........................................................................................................................................................... 14
SW Option Descriptions........................................................................................................................ 14
HW Option Descriptions ....................................................................................................................... 16
Upgrade Management for Releases 1.0 and 2.1 ............................................................................................ 18
Caution against Downgrade ........................................................................................................................... 18
Contact Information ....................................................................................................................................... 19
ONX-610/620/630 Release notes
2
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Release Management 4.0.11
This release is currently available in Stage StrataSync and applies to all OneExpert CATV
DOCSIS 3.0 and DOCSIS 3.1 meters. This release adds Reverse Sweepless Sweep, additional
CDMv2 JSON reports for network modes, updates to OFDM handling in Quick Check Expert,
translation updates, improvements to job management, support for the new SmartOTDR device,
and many other minor improvements as requested by various customers. It also adds several bug
fixes. These new features support network maintenance and home installation technicians. It is
ok to directly upgrade to this release from any previous released version.
This release includes a BCM DOCSIS Modem upgrade from version 17.3 to 19.2.
Main Package Version: 4.0.11
Original Build File Name: ONXCBL.004.000.011.oxu
MD5 sum: 616cb8a51757eb91d25dbf863accba9e
It currently includes the following sub-package version numbers:
• Base: 4.32.011
• Cable: 4.0.11
• Measurement Software Version 3385: 1.6.420
• DOCSIS Cable Modem Version 3385: P.14.1.3385
• Measurement Software Version 3390: 1.7.117
• DOCSIS Cable Modem Version 3390: 19.2
• FPGA: 7.8.5
Release Management 4.0.15
This release is currently available in StrataSync and applies to all OneExpert CATV DOCSIS 3.0
and DOCSIS 3.1 meters. This release adds Reverse Sweepless Sweep, additional CDMv2 JSON
reports for network modes, updates to OFDM handling in Quick Check Expert, translation
updates, improvements to job management, support for the new SmartOTDR device, and many
other minor improvements as requested by various customers. It also adds several bug fixes.
These new features support network maintenance and home installation technicians. It is ok to
directly upgrade to this release from any previous released version.
This release includes a BCM DOCSIS Modem upgrade from version 17.3 to 19.2.
Main Package Version: 4.0.15
Original Build File Name: ONXCBL.004.000.015.oxu
MD5 sum: c396b3654da4a91d0523bb7af24bb7ba
It currently includes the following sub-package version numbers:
• Base: 4.32.15
• Cable: 4.0.15
• Measurement Software Version 3385: 1.6.420
• DOCSIS Cable Modem Version 3385: P.14.1.3385
• Measurement Software Version 3390: 1.7.142
• DOCSIS Cable Modem Version 3390: 19.2
• FPGA: 7.8.5
ONX-610/620/630 Release notes
3
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Release Management 4.0.18
This release is currently available in StrataSync and applies to all OneExpert CATV DOCSIS 3.0
and DOCSIS 3.1 meters. This release adds Reverse Sweepless Sweep, additional CDMv2 JSON
reports for network modes, updates to OFDM handling in Quick Check Expert, translation
updates, improvements to job management, support for the new SmartOTDR device, and many
other minor improvements as requested by various customers. It also adds several bug fixes.
These new features support network maintenance and home installation technicians. It is ok to
directly upgrade to this release from any previous released version.
This release includes a BCM DOCSIS Modem upgrade from version 17.3 to 19.2.
Main Package Version: 4.0.18
Original Build File Name: ONXCBL.004.000.018.oxu
MD5 sum: d33d56ea42e4d2563228e852b17f2ffa
It currently includes the following sub-package version numbers:
• Base: 4.32.18
• Cable: 4.0.18
• Measurement Software Version 3385: 1.6.420
• DOCSIS Cable Modem Version 3385: P.14.1.3385
• Measurement Software Version 3390: 1.7.142
• DOCSIS Cable Modem Version 3390: 19.2
• FPGA: 7.8.5
Release Management 4.0.21
This release is currently available in StrataSync and applies to all OneExpert CATV DOCSIS 3.0
and DOCSIS 3.1 meters. This release adds logic to account for the configured reference
bandwidth as it applies to DOCSIS Upstream Transmit levels. It also adds a few important bug
fixes. It is ok to directly upgrade to this release from any previous released version.
This release includes a BCM DOCSIS Modem upgrade from version 17.3 to 19.2.
Main Package Version: 4.0.21
Original Build File Name: ONXCBL.004.000.021.oxu
MD5 sum: 27b3c7844bebc21dcbcc96e944ace1f4
It currently includes the following sub-package version numbers:
• Base: 4.32.21
• Cable: 4.0.21
• Measurement Software Version 3385: 1.6.420
• DOCSIS Cable Modem Version 3385: P.14.1.3385
• Measurement Software Version 3390: 1.7.213
• DOCSIS Cable Modem Version 3390: 19.2
• FPGA: 7.8.5
ONX-610/620/630 Release notes
4
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Significant Feature Enhancements Added in 4.0.11
The following feature enhancements have been added since the last official release and are
included in this firmware. New features may be protected by the new options. Please contact your
marketing, sales or engineering representative to coordinate the deployment of new options to
your meter.
•
OneCheck
o Added support for reporting DOCSIS related status errors to problems detected
on UI and metadata.
o Added support for AGC Stress
o Added improved AGC logic for handling Excessive Noise or Ingress on port 2
during the ingress test.
o Improved the DOCSIS Upstream widget display to show all channels and handle
OFDMA overlap better.
o Added support for digital adjacent channel delta
o Added support for reporting when HL Leakage is not required in report metadata.
•
ChannelCheck
o Added support for AGC Stress
o Added a graph that shows all channel MER values
o Added support for digital adjacent channel delta
•
DOCSIS Check
o Added DOCSIS status to the report.
o Improved the DOCSIS Upstream widget display to show all channels and handle
OFDMA overlap better.
•
Home TDR
o Added support for CDMv2 JSON report.
•
OneCheck Expert
o Added Sync button to dashboard page
o Added Save button to dashboard page
o Added DOCSIS Status to the reports.
o Added support for enabling or disabling Off-Air Ingress test via meter UI or
StrataSync.
o Added support for AGC Stress
o Improved the DOCSIS Upstream widget display to show all channels and handle
OFDMA overlap better.
o Added support for digital adjacent channel delta
•
Ingress Expert
o Added support for CDMv2 JSON report.
o Added support for persisting view and marker positions
•
Channel Expert
o Added support for CDMv2 JSON report.
o Added support for AGC Stress
o Added a graph that shows all channel MER values
o Added support for digital adjacent channel delta
ONX-610/620/630 Release notes
5
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
•
DOCSIS Expert
o Added support for CDMv2 JSON reports
o Improved the DOCSIS Upstream widget display to show all channels and handle
OFDMA overlap better.
•
Quick Check Expert
o Added support for CDMv2 JSON reports.
o Added improved support for OFDM PLC level, MER and BER measurements.
o Added improved support for OFDM Average level, MER and Profile A
measurements.
o Added improved support for OFDM 6.0 MHz bandwidth measurements.
o Added support for digital adjacent channel delta to full scan mode.
•
Reverse Sweepless Sweep
o Absolute plot support
o Reference plot support
o Added support for StrataSync to assign the ICFR Reference Bandwidth and
sweep display type.
o Saving and viewing results on UI and in StrataSync
o DOCSIS Progress percentage and status
o TPC support
•
OneCheck Fiber
o Added support for SmartOTDR.
•
SmartID
o Added support for displaying reports in StrataSync.
•
Workflow Manager
o Added support for specifying tests to perform in a work order.
o Added support for launching required tests from the workflow manager
o Added support for skipping required tests in the workflow manager
o Added support for listing the completed tests in workflow manager.
•
Misc
o
o
o
o
Updated work order creation to request the name for a new work order when
none exists on the meter instead of creating a new one named default.
Added Korean language support.
Updated sync logic to only require one button press if initiated from a mode that
supports DOCSIS.
Added support for auto-purge logic to happen on mobile tech sync.
ONX-610/620/630 Release notes
6
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Significant Feature Enhancements Added in 4.0.21
The following feature enhancements have been added since the last official release and are
included in this firmware. New features may be protected by the new options. Please contact your
marketing, sales or engineering representative to coordinate the deployment of new options to
your meter.
•
OneCheck, OneCheck Expert, DOCSIS Check, DOCSIS Expert
o Added logic to adjust the reported upstream TX level based on the configured
Reference Bandwidth.
ONX-610/620/630 Release notes
7
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Significant Bugs Fixed in 4.0.11
The following bugs have been fixed since the last official release and are included in this
firmware:
•
Fiber Check
o Fixed a bug that caused only 2 zones to appear.
•
OneCheck Fiber
o Fixed a bug that caused OneCheck Fiber to crash if run after deleting all items in
a profile
o Fixed a bug that caused the mode to sometimes hang if the test failed.
o Fixed other minor bugs.
•
OneCheck
o Fixed a bug that caused Downstream to change to 76% after initiating a retest on
the DOCSIS portion of the test only.
o Fixed a bug that caused OneCheck to sometimes finish with DOCSIS being at
80% and connected.
o Bugfixes applied to CDMv2 reports
o Fixed a bug that caused DOCSIS portion of the test to report complete while
progress was at 99%.
o Fixed a bug that caused limit to show Unknown in CDMv2 reports
o Fixed a bug that caused QAM lock to fail on some channes in OneCheck but lock
in Channel Check.
o Fixed a bug that caused Hum to not appear in reports. This also applies to
OneCheck Expert and Channel Check/Expert modes.
o Fixed a bug that caused work order locations on setup pages to list the status
from a previously selected work order.
o Fixed a bug that sometimes caused DOCSIS to report connected and finished
with progress left at 95%
o Fixed a bug that caused the mode to hang in Initializing Measurement spinner
when significant signal is present on port 2.
•
Channel Check/Expert
o Fixed a bug that caused the DQI value to sometimes not show in reports.
o Fixed a bug that caused an OFDM Carrier to sometimes not show up in Channel
Check/Expert, but it would appear in DOCSIS Check/Expert.
o Fixed a bug that caused the mode to slow significantly when OFDM channel was
selected.
o Fixed a bug that caused Hum and DQI to not be measured on the selected
channel.
•
DOCSIS Check/Expert
o Fixed a bug that caused ICFR y-axis values to be incorrect.
o Fixed a bug that caused OFDMA ICFR values to roll-off incorrectly starting at
approximately 160MHz.
•
Quick Check
o Fixed a bug that caused Tilt carrier mapping to be incorrect on Analog channels.
o Fixed a bug that caused reports to use dBuV instead of dBmV
o Fixed bugs in the CDMv2 reports
ONX-610/620/630 Release notes
8
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
o
Fixed an unclear popup message when adding some carriers to the carrier plan.
•
Spectrum
o Fixed a bug that caused the marker position to be lost when opening Spectrum
Mode.
•
OneCheck Expert
o Fixed a bug that caused OneCheck to sometimes finish with DOCSIS being at
80% and connected.
o Fixed a bug that caused NCP and Profile A to report as unlocked in downstream
but locked in DOCSIS portion of the test.
o Fixed a bug that caused OCE DOCSIS test to take a long time to report first
result.
o Fixed a bug that caused FDC carrier level to be wrong when running the mode
with MER enabled.
•
Ingress Expert
o Fixed a bug that caused units to not print on screen because font was black on
black background.
o Fixed a bug that caused Ingress Expert to crash sometimes.
o Fixed a bug where the level reported between 110 – 160 MHz was about 1 dB
low.
•
Quick Check Expert
o Fixed a bug that caused the mode to hang in Initializing Measurement System
popup when configuring a CW outside of the selected channel plan.
o Fixed a bug that caused the work order font size to change when entering full
scan full screen mode.
•
Forward Sweep
o Fixed a bug that caused Forward Sweep reports to not be viewable in
StrataSync.
o Fixed a bug that caused unreferenced sweep reports to not be visible in
StrataSync
o Fixed the input ranges on forward tilt compensation, forward low tilt frequency
and forward high tilt frequency.
•
Reverse Sweep
o Fixed a bug that caused unreferenced sweep reports to not be visible in
StrataSync
•
Sweepless Sweep
o Fixed a bug that caused tilt frequencies to be incorrectly formatted.
•
OFDM/OFDMA Related Issues:
o Fixed a bug that caused the meter to sometimes report unlock on OFDM Profiles
A and B.
o Fixed a bug that caused the meter to sometimes report unlock on OFDM Profile
B with lock on Profiles C and D. Insufficient Data is reported if there was not
enough traffic in a given profile to adequately test lock status.
o Fixed a bug that caused the OFDM Profile Analysis Widget to sometimes show
blanks on first load.
ONX-610/620/630 Release notes
9
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
o
o
o
o
o
Fixed some discrepancies between the UI and Reports regarding OFDM Profile
results.
Fixed a bug that caused problems with OFDM Carriers that use exclusion zones.
Fixed a bug that caused the profile analysis widget to have missing info when the
OFDM carrier had exclusion zones.
Fixed a bug that caused DOCSIS bonding to fail with some types of OFDM
carriers.
Fixed a bug that caused OFDM echo to be reported as artificially high when
bandwidth was 49 MHz
•
Ethernet Test
o Fixed a bug where status was reported a None in StrataSync but the test file
showed pass.
•
CDM Reports
o Reduced the number of digits reported on Longitude and Latitude values
o Fixed a bug that prevented the zoom button from working as expected.
•
Mobile Tech Integration
o Fixed a bug that caused ONX to hang when there was a problem on the
Bluetooth connection.
o Fixed a bug that caused VNC connection to sometimes terminate while paring
with Android 8 device.
o Fixed a bug that prevented the user from assigning a blank VNC password.
o Fixed a bug that sometimes caused an updated file to not be sync’ed to
StrataSync.
o Fixed a bug that caused missing files to be listed as available for download to the
mobile device.
o Fixed a bug that caused files to be delayed for up to one minute when sending
them to the mobile device.
o Fixed a bug that caused and new Bluetooth pairing to be lost on reboot.
o Fixed a bug that caused problems for Mobile Tech when attempting to download
files that don’t exist on ONX.
o Fixed a bug that prevented downloading a saved channel plan from ONX to
Mobile Tech.
•
StrataSync related issues:
o Fixed a bug that caused some settings to remain as editable when anti-theft
option was deployed to the asset.
o Fixed a bug that caused file metadata to go missing. This would prevent the file
from being able to be opened in StrataSync.
o Fixed a bug that affected zoom settings when generating PDF reports.
o Updated reports to correctly add V to the end of the model version for nonDOCSIS model versions.
o Fixed a bug that caused the existing work order to be modified when a new work
order was created.
•
Translations:
o Fixed a bug that caused USB to stop working while language was set to Dutch.
o Fixed and improved German translations
o Fixed and improved Portuguese translations
o Fixed and improved French translations
o Fixed and improved French-Canadian translations
o Fixed and improved Dutch translations
ONX-610/620/630 Release notes
10
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
o
o
o
Fixed and improved Simplified Chinese translations
Fixed and improved Japanese translations
Fixed and improved Russian translations
•
Workflow Manager
o Fixed a bug that prevented spaces and other punctuation characters from
working when creating a new work order.
o Fixed a bug where auto-saved reports were not being deleted when a work order
expired.
•
Misc:
o
o
o
o
o
o
o
o
o
Fixed a bug that caused BIST to hang when run on a meter that has an ISDB-T
module attached.
Fixed a bug that caused 2nd audio carrier to not report level correctly.
Added Japan to the list of countries in System Settings->International Settings
page.
Fixed a bug that caused QAM Channels to occasionally be reported as 1 dB
lower than they were and then recover to the correct value.
Fixed a bug that caused the session save popup to appear. The work order
should now be correctly saved and compressed.
Fixed a bug that caused the default work order to be created and selected after
sync.
Fixed TPC max and min ranges in test point templates.
Fixed a bug that could cause BIST to fail incorrectly due to the presence of a
Euro BPI+ certificate on a US meter.
Fixed a bug that caused port 1 measurements to be slow to start on some meters
that had previously been sent to services.
ONX-610/620/630 Release notes
11
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Significant Bugs Fixed in 4.0.15
The following bugs have been fixed since 4.0.11 and are included in this firmware:
•
OneCheck, OneCheck Expert,
o Fixed a bug where sync from details results pages didn’t work.
o Fixed a bug where the high diplexer was incorrectly chosen when the setting was
Auto.
o Fixed a bug that caused the OFDM Profile A to sometimes be incorrectly listed
as insufficient data with failed limit.
•
Docsis Expert
o Fixed a bug that caused the ICFR Bar graph view to be inverted.
•
Misc Bug Fixes
o Fixed a bug where OFDM MER levels were 5-10 dB too low.
o Fixed a bug where QAM MER was 1-3 dB low when running immediately
following a software upgrade or change of DOCSIS Service Plan.
o Fixed a bug where blocks of 2-3 channels went missing from the channel plan
build.
o Fixed a bug that occasionally caused Channel Check, Channel Expert, DOCSIS
Check and DOCSIS Expert to crash if they were run for 1.5+ hours.
Significant Bugs Fixed in 4.0.18
The following bugs have been fixed since 4.0.15 and are included in this firmware:
•
HL Leakage
o Fixed a bug that could cause the application to crash if you pressed pause while
the initialization spinner was running.
•
OneCheck Expert
o Fixed a bug that could cause the sessionexpert file to fail to save after changing
DOCSIS Service Plan
•
Reverse Sweep
o Fixed a bug that caused the forward telemetry to be displayed in reports instead
of the reverse telemetry
•
Reverse Sweepless Sweep
o Fixed a bug that could cause the mode to crash if run after running Reverse
Sweep.
•
Workflow Manager
o Fixed a bug where the active work order would sometimes change to the
previous active work order after reboot when manually creating a work order.
ONX-610/620/630 Release notes
12
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Significant Bugs Fixed in 4.0.21
The following bugs have been fixed since 4.0.18 and are included in this firmware:
•
Ingress Expert
o Fixed a bug that caused the FPGA_0 popup to occur followed by requiring a
forced reboot of the meter.
•
Reverse Sweep
o Fixed a bug that occasionally caused the ONX to output a burst of noise at the
beginning of the reverse sweep cycle.
•
Reverse Sweepless Sweep
o Fixed a bug that caused the upstream TX levels to vary by 1-2 dB on back-toback runs of the mode without changing the connection.
•
Mobile Tech
o Fixed multiple bugs that could cause the ONX Bluetooth to disconnect from the
mobile device.
•
StrataSync
o Fixed a bug that prevented the user from changing the StrataSync account ID or
tech ID when anti-theft is enabled.
ONX-610/620/630 Release notes
13
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Known Limitations
Channel Plan Build Limitations
•
•
Non-FDC Digital Channels with bandwidth less than 6 MHz are not detected.
DAB+ channels are not detected.
StrataSync Limitations
•
Sync via IPv6 only connection is not supported.
Options
Options will typically be deployed to a meter at manufacturing. StrataSync also has the ability to
deploy permanent and demo options. Please contact your sales support representative for
assistance with option deployment.
SW Option Descriptions
The ONX currently supports the following software options:
1. ONX-610 – identifies the meter as an ONX-610 (available only at manufacturing)
o Enables 16x4 DOCSIS
o Enables lower triplexer selection only.
2. ONX-620 – identifies the meter as an ONX-620 (available only at manufacturing)
o When deployed, this option also enables the following SW options:
§ ONX BLUETOOTH SW OPT
§ ONX MOBILE SW OPT
§ ONX DOCSIS 32x8 BONDING
o Enables multiple triplexer frequency selections, low, high or AUTO depending on
HW variant.
3. ONX-630 – identifies the meter as a sweep capable ONX-630 (available only at
manufacturing)
o When deployed, this option also enables the following SW options:
§ VoIP
§ Ookla Speedtest
§ IPX PACKAGE
§ TSX PACKAGE
§ NTX PACKAGE
§ ONX BLUETOOTH SW OPT
§ ONX MOBILE SW OPT
§ ONX DOCSIS 32x8 BONDING
§ ONX DOCSIS 3.1 OFDM
§ INGRESS EXPERT
§ RSG LOOPBACK
§ Ookla Speedtest
§ OneCheck Expert
o Enables multiple triplexer frequency selections, low, high or AUTO depending on
HW variant.
4. ONX BLUETOOTH SW OPT – enables Bluetooth communication. This allows Bluetooth
pairing with an iPad for remote UI viewing and also for Bluetooth enabled SmartIDs.
ONX-610/620/630 Release notes
14
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
5. ONX MOBILE SW OPT – enables remote communication with an iPad or other mobile
devices that are running our ONX-CATV application for remote interface viewing.
6. Ookla Speedtest – enables the Speedtest by Ookla application from within Ethernet
mode
7. SmartAccess Anywhere – enables the SmartAccess Anywhere feature on ONX which
allows remote access to the device without having to have a public IP on the ONX.
8. VOIP MOS – enables the MOS section of testing for VoIP tests in Ethernet test mode.
9. ONX IP VIDEO SW OPT – enables IP Video tests from within the Ethernet test
application.
10. TrueSpeed – enables TrueSpeed testing from within the Ethernet test application.
11. VoIP – enables VoIP tests from within the Ethernet Test app.
12. IPX PACKAGE – enables service layer tests over DOCSIS. This includes Throughput,
Packet Quality, Ping and Trace Route.
o When deployed, this option also enables the following SW options:
§ VoIP
§ Ookla Speedtest
13. TSX PACKAGE – enables all IPX-Package capabilities plus advanced RF
troubleshooting measurements. For a complete list, please reference marketing material.
o When deployed, this option also enables the following SW options:
§ VoIP
§ IPX PACKAGE
§ Ookla Speedtest
14. ONX DOCSIS 32x8 BONDING – allows for selection of DOCSIS 3.0 24x8 and DOCSIS
3.0 32x8 channel bonding when performing DOCSIS Tests.
15. ONX DOCSIS 3.1 OFDM – enables DOCSIS 3.1 OFDM testing and connection
capabilities.
o When deployed, this option also enables the following SW options:
§ ONX DOCSIS 32x8 BONDING
16. ONX FORWARD SWEEP – enables forward sweep testing on sweep hardware capable
meters (ONX-630)
17. ONX REVERSE SWEEP – enables reverse sweep testing on sweep hardware capable
meters (ONX-630)
o When deployed, this option also enables the following SW options:
§ REVERSE ALIGNMENT
18. ONX MoCA – enables MoCA testing on MoCA hardware capable meters (reserved for
future software capabilities).
19. NTX PACKAGE – enables network expert test modes (e.g. Channel Expert) in the CATV
Network application group.
o When deployed, this option also enables the following SW options:
§ VoIP
§ IPX PACKAGE
§ TSX PACKAGE
§ INGRESS EXPERT
§ RSG LOOPBACK
§ Ookla Speedtest
§ OneCheck Expert
20. SWX PACKAGE – enables all sweep test modes (e.g. Forward Sweep) in the CATV
Network application group on sweep hardware capable.
o When deployed, this option also enables the following SW options:
§ VoIP
§ IPX PACKAGE
§ TSX PACKAGE
§ NTX PACKAGE
§ ONX FORWARD SWEEP
ONX-610/620/630 Release notes
15
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
§ ONX REVERSE SWEEP
§ SWEEPLESS SWEEP
§ REVERSE ALIGNMENT
§ INGRESS EXPERT
§ RSG LOOPBACK
§ Ookla Speedtest
§ OneCheck Expert
SWEEPLESS SWEEP – enables sweepless sweep mode.
REVERSE ALIGNMENT – enables reverse alignment on sweep hardware capable
meters (ONX-630).
INGRESS EXPERT– enables Ingress Expert.
RSG LOOPBACK – enables RSG Loopback App (Return Signal Generator with TX, RX
and Loopback capabilities)
ONX DOCSIS – enables all DOCSIS functionality on the meter. This option is displayed
only if it is not enabled.
RSG TX – enables RSG TX App (Return Signal Generator with TX only mode of
operation).
HOME TDR – enables the Home TDR App in the CATV application group.
Ookla Speedtest – enables Ookla Speedtest in Ethernet Test.
HL Leakage – enables HL Leakage App in the CATV application group.
Field View – enables Field View App in the CATV Network application group.
Field View with RSG – enables Field View with RSG App in the CATV Network
application group.
o When deployed, this option also enables the following SW options:
§ Field View
DataBase Mining – enables saving database data with all files instead of just the
sessionexpert or onechecksessionexpert result files.
OneCheck Expert – enables the OneCheck Expert mode.
ONX REVERSE SWEEPLESS SWEEP – enables Reverse Sweepless Sweep
HW Option Descriptions
The ONX currently reports the following HW options to StrataSync. Hardware options are used to
help identify the hardware capabilities of the ONX.
1. DOCSIS 3.0 HW capable – this option identifies that the ONX has the hardware
necessary to accomplish a DOCSIS 3.0 connection. ONX that report this option do not
have the hardware necessary to perform a DOCSIS 3.1 OFDM connection.
2. DOCSIS 3.1 HW capable – this option identifies that the ONX has the hardware
necessary to perform a DOCSIS 3.1 OFDM connection.
3. Low Diplexer – this option specifies the low triplexer frequency range (e.g. 42 – 1002
MHz.)
4. High Diplexer – this option specifies the high triplexer frequency range (e.g. 85 – 1002
MHz).
5. INGRESS SCAN RANGE 4-110 MHz – This option specifies that the port 2 ingress scan
has the range 4 – 110 MHz
6. INGRESS SCAN RANGE 4-204 MHz – This option specifies that the port 2 ingress scan
has the range 4 – 204 MHz.
7. Sweep Capable – This option identifies that the ONX has the hardware necessary to
perform forward and reverse sweep measurements.
ONX-610/620/630 Release notes
16
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
8. DOCSIS 3.0 Euro BPI+ Certs – This option indicates that DOCSIS 3.0 Euro BPI+ Certs
have been successfully deployed to the ONX.
9. MoCA 2.0 Bonding Capability – This option indicates that the ONX has the hardware
necessary to perform MoCA 2.0 bonding.
10. MoCA 2.0 Capability – This option indicates that the ONX has the hardware necessary
to perform MoCA 2.0 (bonding not supported).
11. WiFi Country – This option reports the two letter WiFi country code that the meter is
currently configured to use.
12. WiFi Region – This option reports the configured WiFi region (FCC/IC or ETSI).
13. Port 2 Clamping – This option indicates the presence of a clamping diode on port 2.
14. HL Leakage Capable – This option indicates that the ONX has the hardware necessary
to perform HL Leakage.
15. Field View Capable – This option indicates that the ONX has the hardware necessary to
perform Field View.
16. Large Flash – This option indicates which flash part is on the module.
17. Digital Hum Capable – This option indicates that the ONX has the hardware necessary
to perform Digital Hum Measurements.
18. Atypical EEPROM – This option indicates that you might want to call TAC.
ONX-610/620/630 Release notes
17
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
Upgrade Management for Releases 1.0 and 2.1
Please use the following procedure when updating the firmware on your OneExpert CATV if it is
running any version prior to 2.0.655. This procedure can be used for newer releases also.
1.
2.
3.
On the OneExpert CATV meter:
a. Power on your meter, connect it to power and/or make sure it has greater than 50%
battery.
b. Open the Network application that is under the System group at the bottom of the
page.
i. Do not open the Ethernet application. If you do, please reboot and start over.
(1.0.0 and 1.0.1 only)
c. Verify that you have a valid IP address. You may have to press the "Ethernet" button
(soft key 2) at the bottom of the screen to enable the network connection.
i. If your IP address starts with 192.168.0.*, you may have difficulties with
downloading the file. We recommend either of the following:
1. Reconfigure the modem/router to use anything but 192.168.0.*
2. Perform upgrade via USB with no cable attached to either Ethernet
port. If you perform the upgrade via USB, be sure to cancel the
upgrade in StrataSync or it will attempt to upgrade your meter again
on next sync.
d. Once you have a valid IP address, press the home button.
On StrataSync:
a. Deploy the desired SW update to your meter from StrataSync.
On the OneExpert CATV:
a. Open the StrataSync application that is under the System group at the bottom of the
page.
b. Start a Sync, the meter should prompt you to "Click OK to accept the update", accept
the update and allow the meter to upgrade.
i. If the meter does not prompt you to “Click OK to accept the upgrade”,
redeploy the upgrade from StrataSync and Sync again.
c. The ONX will automatically power off when the upgrade completes successfully.
Caution against Downgrade
The OneExpert CATV applications will not work if you downgrade from this release to any version
prior to 2.2.86. Appropriate use of StrataSync generally prevents downgrading the meter. If you
downgrade the OneExpert CATV and it doesn’t work as desired, please upgrade it back to this
release or later to restore normal operation. We recommend that you not downgrade your
OneExpert CATV.
If your meter has the DOCSIS 3.1 HW capable and the Port 2 Clamping hardware options, then
attempts to downgrade to versions to earlier than 3.4.8 or 3.4.11 will probably fail. Your meter will
be unusable until you re-upgrade to release 3.4.17 or newer. It will likely require two attempts to
successfully upgrade your meter back to this release should you decide to disregard this warning.
If your meter has the Sweep Capable hardware option and doesn’t have the Large Flash
hardware option, the ONX will become useless if it is downgraded to any software image earlier
than 3.10.4. It will likely require two attempts to successfully upgrade your meter back to this
release should you decide to disregard this warning.
ONX-610/620/630 Release notes
18
Build 4.0.21 Release Notes
ONX-610 / ONX-620 / ONX-630
If you downgrade a meter from 3.17.x to an earlier revision, work order data may be lost and
permanently consume file system space until you re-upgrade to 3.17.x or later. You can avoid this
by performing a manual purge prior to performing the downgrade.
Contact Information
For help, please consult the User’s Guide or contact VIAVI Support
USA
Outside the US
Email
Company Website
Support Website
+1-844-GO-VIAVI or +1-844-468-4284
+1-855-275-5378
CATVSupport@viavisolutions.com
www.viavisolutions.com
www.viavisolutions.com/support
ONX-610/620/630 Release notes
19
Download