Effect Of Load and Field Current Changes in Synchronous Motor Presentation -01 Name :Mir Rafsan Student ID :1711013 Synchronous motor are Synchronous machines used to convert electrical power to mechanical power Objective: For Load and Field Current Changes We will see how Internally Generated Voltage (EA ) power factor (Pf) and Armature current (IA ) changes Vϕ Phasor Diagram θ δ J IA X s IA EA For lagging condition Phasor Diagram Effect Of Load Changes in Synchronous Motor: We know Internally Generated Voltage, E A =K ϕ ω ω and ϕ Constant So E A =Constant where ω =synchronous speed of Motor and ϕ =Flux Leading power factor Unity Power factor Lagging Power Factor Vϕ IA2 IA1 Vϕ θ2 θ1 θ3 θ4 IA4 IA3 Vϕ IA5 δ5 δ3 δ4 EA5 δ1 EA1 δ2 EA3 EA2 Load δ IA θ EA4 Cosθ Load δ IA θ Cosθ Locus point Effect Of load changes in Leading ,Unity and Lagging Power factor Effect on Field Current Changes: Real Power Supply ∝ Load on synchronous Motor (As Load=Constant So P=Constant) 3 Vϕ E Sin δ p= Xs EA Sin∝=K E=K ϕ ω ω=constant P=√3 VICos θ ϕ ∝ If E A ∝ If IA Cos θ=k P=Real Power ϕ = Flux IA Cos θ IA Cos θ θ1 θ2 θ4 IA2 E A Sinδ E A2 IA5 Vϕ E A3 E A1 E A Sinδ Vϕ E A Sinδ E A5 E A4 Lagging If IA3 θ3 Vϕ IA1 IA Cos θ IA4 EA I A θ Cosθ Unity PF Leading PF PF If EA I A θ Cos θ Figure:Effect on Field Current Changes Effect of Field Current in Leading ,Unity and Lagging Power factor V curve Synchronous Motor Thank You