Solenoid pump Type CP 3A.xxx.y
110/120V 60Hz- 55W
•Technical Specification
•Pump drawing for dimensional purpose
•Material characteristics
•Functional characteristics
•Flow graph
•Process flow summary
1
Invensys La Morra Plant
•Pump drawing for dimensional purpose
2
Invensys La Morra Plant
Material characteristics
Overall dimensions according to the attached drawing
Hydraulic body
PA 66 30% glass fibre
Sealing valves
Rubber
Shock absorber
EPDM rubber
Metallic parts in contact with the
working fluid
Electrical connections
Diode
Electrical insulation
Degree of protection
Approvals
(only if equipped with
thermostat, see below
type)
Stainless steel
6,3 x 0,8 faston terminals, tin plated
Equipped with internal diode connected in series
with the copper winding
ordinary
UL: REUZ2. E101614 (UL778-4 Edition)
CANADA: REUZ8. E101614
Functional characteristics
Working fluid
Nominal power supply
Environment temperature
Heating test
Resistance to Heat, Fire……
Dry working
Thermostat
Functional defined characteristics:
Potable grade water; max temperature Tm. 35°C
according to the approval
110/120V -60 Hz cycle 1min ON-1,5 min OFF
Power absorption: 55 W
Ambient 25°C
Class A (according UL778-4Ed.standard).
according UL778-4Ed.standard.
allowed only for the self priming phase
Thermostat type Texas 1NT series (115°C); fixed with
metallic clamp
Flow Rate: from 100 to 250 mL/min at 10 Bar at
120V/60Hz
Max. Pressure (outlet blocked): from 13 to 18 Bar at
120V/60Hz
Suction power: 100mBar minimum, self priming without
pressure on the outlet side (zero back-pressure)
3
•Flow graph
Invensys La Morra Plant
CP3A 120V/60Hz ( Flow average at 120V/60Hz)
700
636
600
Flow [cc/min]
500
415
400
369
284
300
200
186
135
100
69
0
0
2
4
6
8
10
12
14
Back Pressure (Bar)
Rev.0 July-06
4
PL Toolbar
Print
Copy
CP Pump-Process Layout Summary
Name
W.Alessandria
Date
12/02/2008
INVENSYS
La Morra Plant
Qaulity Assurance
Main Menu
Example
Spring and valve
preassembly
Teflon ring
selection
Coil winding
Wire tin welding
!00% Electrical tests:
(Eletr. Resistance; Surge
test; Diode test)
Coil
rework
Pressure chamber preassembly
Coil over-injection
Coil visual control
Pump assembly
100% Pump high voltage test
Stat. Control for bush torque
force
100% Pump final test for:
Suction
Max pressure
Flowrate
Diode
Pumps Rework
Thermostat (option)
Visual Control
Pump packaging
5
Download