OFFICE STANDARDS Floor to ceiling height – 2.75m (min-2.5m) Duct space- 0.5m Ramp – 1:12 (every 30’ interval – 1 landing) BASIC SPACE MODULE 75 sq.ft – individual desk with clerk activities 150 sq.ft – 1 reporting officer or 2 clerk typist 225 sq.m – office of supervisor with 2 secretaries or 3 clerk typist SPECIAL ROOMS – FOR 15 PEOPLE (SQ.M) (+10 sq.ft for every additional person) Reception – 400 Waiting room – 200 Interviewing room – 200 Conference room – 500 Floor to ceiling height for floor area Upto 50sq.m – 2.5m Over 50 sq.m – 2.75 m Over 100 sq.m – 3m Over 250 and upto 2000 sq.m – 3.25m WORKSTATIONS - Workroom min – 8sq.m Circulation space 1.5 sq.m per employee (min -1m) Office employee – 4.5 sq.m Secretary - 6.7 sq.m Departmental Manager – 9.3 sq.m Director – 13.4 sq.m Assistant Vice president – 18.5 sq.m Vice president – 28 sq.m - Minimum width of the corridor – 2m - Parking o One car space for every 100 square metres of floor area or part thereof - Minimum road width – 18m - Maximum height of the building – 15m or (G+3) or slit + 4 floors - Maximum Floor space index – 1.5 - Maximum Plot coverage – 60% FIRE ESCAPE - The occupancyfactor in open-plan offices exceeding 60m2is 6m2per person, or 7m2per person for cellular offices. Minimum widths for escape routes: 750 mm for 50 persons 850mm for 110 persons 1050mm for 220 persons +5 mm per person above 220 persons