ATEX Labelling & meaning Gas detection computer NDIR-Transmitter for combustible gases Zone 0 and Zone 1 Range of application Transmitter for toxic gases and oxygen Classification of zones Ingress protection Foreign bodies protection Category 1: very high safety level Saftey guaranteed by 2 protective measurements / with 2 independent apparatus faults 0 1 2 3 4 5 6 Application in zone 0, 1, 2 / 20, 21, 22 - Atmosphere G / D Category 2: high safety level Sufficient safety when apparatus faults occur often / with 1 fault Application in zone 1, 2 / 21, 22 - Atmosphere: G / D Category 3: normal safety level no protection foreign bodies >50 foreign bodies >12,5 foreign bodies >2,5 foreign bodies >1,0 dust protected dust-proof Application in zone 2 / 22 - Atmosphere G / D Addition to range of application zone 0 dusts Required marking of installation Equipment group Category group Equipment protection level II 1G Ga 2G 1G 3G 2G 1G Gb Ga Gc Gb Ga II 1D Da II 2D 1D Db Da 3D 2D 1D Dc Db Da M1 M2 M1 Ma Mb Ma zone 1 II is not likely to occur in normal operation but, if it does occur, will persist for a short period zone 2 II is present continuously or for long periods or frequently zone 20 is likely to occur in normal operation occasionally zone 21 is not likely to occur in normal operation but, if it does occur, will persist for a short period zone 22 II mines I mines I occassionally - methane dusts Examination Certificate according to RL 94 / 9 / EG Selection of notified bodies according to guideline 94 / 9 / EG Country Notified body Code D DEKRA EXAM 0158 D BAM 0589 D PTB 0102 DK DEMKO 0539 F INERIS 0080 Apparatus may be used in IIA Explosion subgroup IIA IIB IIC IIB IIC T1 Function test Maximum security for the operator is guaranteed, if gas detectors are function-tested by accredited and independent institutions (DEKRA EXAM). The measurement function according to ATEX (DIN EN 60079-29-1) guarantees highest operational readiness and exact measurements. Ambient temperature Ta Ta: -20°C ... +55°C It is important to redeem to specific ambient temperature ranges, as otherwise the specification of the temperature class can not be guaranteed. T2 methane ethane propane i-butane acetone toluene ammonia propylene ethylacetate town gas carbon monoxide hydrogen T3 T4 benzene cyclohexan hexane kerosene pentane n-octane nonane ethylenoxide ethylene dimethylether 2-butene 1-propanol hydrogenbutadien 1,4-dioxane sulfide n-butane ethanol methanol i-pentane isopropanol 1-butene i-octane cyclopentane acetylene 300°C 450°C > 450°C acetaldehyde butyraldehyde diethylether dibuthylether - - 200°C 300°C 135°C 200°C T1 T2 T3 Notified body Explosion protection Ex Year According to guideline 94 / 9 / EG Principle of protection Type of protection Marking May be used in zone CENELEC transmitter a propagation of an explosion inside to the outside is excluded flammable enclosure „d“ Ex d EN 60079 - 1 junction boxes, cable glands, transmitter avoidance of arcs, sparks and excessive temperature increased safety „e“ Ex e EN 60079 - 7 sensors limitation of energy as well as arcs and temperature intrinsic safety „i“ Ex ia Ex ib Ex ic EN 60079 - 11 pressurisation „p“ Ex p EN 60079 - 2 encapsulation „m“ Ex ma Ex mb EN 60079 - 18 oil immersion „o“ Ex o EN 60079 - 6 powderfilling „q“ Ex q EN 60079 - 5 Ex n EN 60079 - 15 GB SIRA 0518 GB Baseefa 1180 I CESI 0722 N NEMKO 0470 transformers, relays, control stations transformers, relays, condensers NL KEMA 0344 transmitter for zone 2 electronics within transmitter 85°C 100°C T4 T5 T6 Serial number of testing ex-atmosphere keep at distance from the ignition source ex-atmosphere keep at distance from the ignition source ex-atmosphere keep at distance from the ignition source ex-atmosphere keep at distance from the ignition source see at the top only for zone 2 GfG Gesellschaft für Gerätebau mbH Klönnestrasse 99 D-44143 Dortmund Tel.: +49 (0)231 - 56 40 00 Fax: +49 (0)231 - 51 63 13 Worldwide Supplier Of Gas Detection Solutions “non-sparking“ „n“ Requirements Marking without restriction - special condition may be noted X 2 - 0081 General requirements 1 For all application LCIE 100°C 135°C Restriction for using apparatus 0 F sulphide of carbon d e ia IIC T4 Ga BVS 09 ATEX E135 X Protection types switch- and control cupboards, analyse-apparatus - - - Apparatus may be used in 1G Typical application T5 T6 Temperature classes of gases and vapours according to the ignition temperature Explosion protection 0158 II Monitoring of production 0 no protection mm 1 vertical falling wasser mm 2 dripping water on apparatus mm with slope 15° mm 3 spraying water 4 splashing water 5 water jets 6 powerful water jets 7 temporary submersion 8 permanent submersion Function-tested multigas-detectors for up to 7 gases Subdivision of gases and vapours Flammable Temporary behaviour of Subdivision substances flammable substances in of hazardous hazardous places places gases is likely to occur in vapours normal operation IP67 Water protection Sufficient safety during faultless operation is present continuously or for long perdiods or frequently Smart single-gas detectors EN 60079 - 0 Ex component, which is not intended to be used alone and requires additional certification CE-Conformity is declared by the manufacturer if the part is fitted into a complete device U As of 01.02.2010 Portable and fixed gas detection instruments www.gasmessung.de