R Electronic Air Cleaner Air Cleaner equipment expert ShenzhenGuangJieEnvironmentalProtection(Group)Co.,Ltd. R Add:BuildingC,HuaxinruimingIndustrialZone,DalangStreet, LonghuaDistrict,Shenzhen,Guangdong,China Tel:400-638-08090755-29009495 Electronic Air Cleaner Fax:0755-29009495 Email:gojek@szgjhb.com UserManual 30millionPingAnInsuranceescort OfficialWechat OfficialWebsite Shenzhen Guang Jie Environmental Protection (Group) Co., Ltd. is a joint venture established by Singapore PREMIER ELECTROSTATIC AIR CLEANER and Guang Jie Environmental Protection Group. is located at Shenzhen, Which is High Technique and ResearchbaseofChina.Asaleadingtechnologyenterprise,patentdemonstrateCompany,weareacompanydedicatedtoproduction andresearchofoilfumepurificationESP,oilmistcollector,smoke-freeBBQcar,Integratedrangehood,waste-gasdealingequipment etc.Wehaveprecisionmachiningworkshop,Nationalstandardresearchlaboratory,Techniquecenter,andindustrialstandardlab. With"Environment-friendly,Customer-oriented,Teamwork,Excellence”asourguidingprincipleinthemarket,weleadthetrends ofconsumermarkets;wealsoshareaccessoryresourcewithfamousbrandsofhomeappliancesinhomeandabroad,activelyengage ourselves in technique-related international communication and cooperation. We have also, through our cooperation with International Cooperation Organization(GIZ), imported the latest fifth Generation oil fume purification technique of Germany RWE International environmental protection Group, digested and absorbed multiple leading technologies , enhanced the capability of techniqueresearch,andsetupscientific,systematichumanresourcessystem. R Gojek are giving financial aid tomorepoorchildrenstohelp themtogotoschool. Electronic Air Cleaner User Manual Performanceoverview GOJEK-EAC-CTA,GOJEK-EAC-CTBflushembeddedcommercialtype Anionairpurificationsterilizationmachine GOJEK-EAC-CTA,GOJEK-EAC-CTBflushembeddednegativeionairpurificationandsterilizationmachine isanairpurificationdevicedesignedforairports,hospitals,conferencerooms,officesandrestaurants,itis suitableforinstallationinlightSkeletonontheceiling. GOJEK-EAC-CTA,GOJEK-EAC-CTBnegativeionairpurificationsterilizationmachinecanfilteroutvarious pollutants using air as the medium through the internal air circulation system, such as dust, bacteria, smoke, pollen and greater filterability Pathogens, etc. According to different environmental conditions, different types of rear filter can be selected to filter out harmful gases or odors such as formaldehyde and ammonia. GOJEK-EAC-CTA,GOJEK-EAC-CTBnegativeionairpurificationsterilization machinehasthefollowingcharacteristics: Using GB6921-86 and GB / T18204.1-2000 method to measure, it can filter out more than 95% of contaminated dust from the air. GOJEK-EAC-CTA's self-circulating air system of centrifugal fan driven by a three-speedmotor,thecirculatingairvolumeperhourcanreach780m³,GOJEK-EAC-CTBcanreach1500m³ Thehigh-voltagepowersupplysystemwithvoltagestabilizationandcurrent-limitingfunctionsensures that the electronic dust collection unit still maintains the best working efficiency in the state of adsorbing dust. Thereisagassensorinsidethemachine.Whenthesensordetectsthattheindoorairqualityexceedsthe standard (such as diffuse cigarette smoke), the internal fan automatically switches to the maximum wind speed Thereisagassensorinsidethemachine.Whenthesensordetectsthattheindoorairqualityexceedsthe standard (such as diffuse cigarette smoke), the internal fan automatically switches to the maximum wind speed,untiltheindoorairqualityreturnstothenormalvalueandthenautomaticallyreturnstotheoriginal windspeed. Whenthegridpanelisopened,thesafetyswitchisautomaticallyturnedofftoensuresafety. WashableelectronicdustcollectionunitandPre-filter. TheworkingstatusofthepanelwithLEDdisplayisclearataglance. Itisconvenienttocheckwhetherthehighvoltageisnormalthroughthe"test"button. According to different environmental conditions, different types of post-filters can be selected to filter outdifferentodorgases. Thespeciallydesignedgridpanelcanrealizethelargecirculationofindoorair. Use the remote control to operate the air purifier-power on and off, wind speed adjustment, Power off andpoweronregularly. Air Cleaner equipment expert Air Cleaner equipment expert CONTENTS 2.Compositionandworkingprinciple 2.1Composition: 1PerformanceOverview GOJEK-EAC-CTA and GOJEK-EAC-CTB are basically the same, mainly composed of two-zone electronic 2Compositionandworkingprinciple 01 2.1Composition 01 2.2Workingprinciple 01 3Performanceandindicators 02 4Installation 04 4.1Calculationofthenumberofairpurificationsterilizationmachines 04 4.2Selectionofinstallationlocation 06 4.3Installingprogram 06 4.3.1Unboxing 07 4.3.2Installationsteps 07 5GOJEK-EAC-CTA,GOJEK-EAC-CTBoperation 11 5.1Panel 11 theactionofthehigh-voltageDCelectricfield,thegaspassingthroughthecoronaareaisionizedtogenerate 5.2Operation 12 a large number of free electrons and positive ions. These free electrons and positive ions are opposite in 6Maintenance 13 6.1CleaningtheelectronicdustchamberandPre-filter 13 These free electrons and ions come into contact with the dust particles in motion to charge the 6.1.1Disassemblystepsofelectronicdustchamberandfilter 13 dust.Under the action of electric field force, these dust particles due to electric field charge or diffusion 6.1.2Cleaning 14 charge move on the one hand to the electrode of opposite polarity in the corona area, part of the charged 6.1.3ReinstalltheelectronicdustchamberandPre-filter 14 dust collection unit, high voltage power supply unit, fan speed control circuit, three speed centrifugal fan,Pre-filter,Rearfilter,aninterlockswitch,afunctionselectionswitch,agassensor,atestbutton,anLED panelthatdisplaystheworkingstatusofthesystem,andaremotecontroller. The difference between GOJEK-EAC-CTA and GOJEK-EAC-CTB is that CTA uses one electronic dust collectionunit,whileCTBusestwoelectronicdustcollectionunits. 2.2Workingprinciple: Driven by the fan in the machine, the indoor air is continuously sucked into the machine through the panel,passesthroughthepre-filter,andfiltersoutlargeparticlesofdust,andthenentersthehigh-efficiency electronicdustcollectionunit.Efficientelectronicdustcollectionunitiscomposedofcoronaareaanddust collectionarea.Ahighvoltageofabout8000voltsDCisappliedtotheelectrodesinthecoronaarea.Under polarity under the action of the electric field. The direction of the electrode moves, colliding with the gas moleculesinthemovement,makingitionized,andgeneratingmorefreeelectrons. particles are adsorbed on the corona plate,on the other hand, most of the charged particles flow into the dust collection area with the air flow. The dust collecting area is composed of a plurality of plate-shaped 6.2Maintenanceandinspection 15 7Remotecontroller 16 Under the action of direct current, the charged dust particles move to the polar plates of opposite 7.1Panelsettingsandfunctions 16 polarityandareadsorbedonthepolarplates.Thecleanairafterremovingthedustisblownintotheroom 7.2Operation 16 8Diagram 17 9Packinglist 19 polarplates,andaDCvoltageofabout4000voltsisadded. throughtherearfilter. Different types of rear filters can remove different odors, and also remove harmful gases such as formaldehydeandammonia. 01 Air Cleaner equipment expert Air Cleaner equipment expert 3.Performanceandindicators InstallationEnvironment: Inputvoltage:220V±15%Frequency:50HZ CTAandCTBnegativeionairpurificationandsterilizationmachinesarenon-explosion-proofproducts.They Coronapolevoltage:8150VDC can only be installed in environments without explosive gases, vapors, etc., and should not be installed in dustyenvironmentswithpotentialexplosionhazardsorwhereelectronicequipmentwithexplosionhazards Dustroomvoltage:4075VDC exists. Motor:Athree-speedenclosedrollingbearingmotorisused. Weight:kg PowerconsumptionandCurrent: GOJEK-EAC-CTA GOJEK-EAC-CTB GOJEK-EAC-CTA GOJEK-EAC-CTB Electronicintegratedunit 4.3 4.3 NetWeight 26 39 GrossWeight 30 48 Windspeed A VA A VA Hight 0.53 116 1.1 242 Medium 0.49 108 0.97 213 Low 0.37 81 0.86 189 4.Installation 620 1210 370 25 Medium 11 21 Low 7.5 13 570 647 13 35 50 575 Hight 620 GOJEK-EAC-CTB 610 GOJEK-EAC-CTA 620 Windspeedsetting 330 715 50 610 Circulationairvolume: m³/min 50 50 1160 Efficiency:95% GB6921-86GB/T18024.1-2000。 Usestandard:GB6921-86GB/T18024.1-2000. GOJEK-EAC-CTA GOJEK-EAC-CTB Storageofenvironmenttemperature:-25℃-60℃ Operatingenvironmenttemperature:0-40℃ Operatingenvironmenthumidity:maximum90%(nocondensation) Color:grayishwhite 03 04 Air Cleaner equipment expert Air Cleaner equipment expert 4.Installation Calculation:Calculatetheroomvolume: 5×7×2.6=91m 3 ! Warning: CTA and CTB do not have an explosion-proof function, and CTA or CTB air purification sterilizers must not be installed in any environment with potential explosive gas, vapor, or dust explosion CheckCTAmaximumairoutputperminuteis14m3/minute(840m3/hour). Determinethenumberofairexchangesperhour: hazard.Otherwise,thereisadangerofexplosion. 4.1Calculationofthenumberofairpurificationsterilizationmachines: Ifitisasmoke-freeoffice,8ispreferred. The number of air purification and sterilization machines that need to be installed in the application spaceismainlybasedonthefollowing: CTAquantity=8× Thevolumeoftheroom; 91m 3 840m 3 /H = 0.87 Numberofpeopleintheroom; Pollutionsourcesintheroom; NeedtoinstallaCTA. Thepurposeoftheroom; Outdoorairquality. This basis can be used as a guiding principle. The amount of air exchange per unit time determines the amount of clean air obtained, and the amount of air exchange per unit time Meetingrooms,barsandotherplaceswhichpeopleconcentrated,andthenumberofairpurificationand sterilizationmachinescanbecalculatedaccordingtothenumberofpersonnel: dependsonfactorssuchasthesourceofpollutionintheroom,theuseoftheroom,thequalityof theoutdoorair,thestructureoftheroom,andtheairflowpattern. Numberofairpurificationsterilizationmachine= Numberofaircirculationrequiredperminute(m 3) airpurificationsterilizationmachineairoutpu( t m 3 /h) Intheabsenceofotherconsultations,thenumberofCTAorCTBrequiredcanbecalculatedasfollows: Installationspacevolume(m 3) Numberofpurificationmachinesrequired=K Airpurifierairoutpu( t m 3/H) Example:Howmanyairpurifiersneedtobeinstalledinanamusementhallormeetingroomwithanaverage capacityof70people? Calculation:Theminimumaircirculationperpersonperminuteis1m³/min,thereare70people, Kisthenumberofairexchangesperhour. Thetotalaircirculationis1m³/min×70people=70m³/min Accordingtodifferentroomusesandgrades,6to20canbeselected; ThemaximumairoutputofCTAis14m³/min, Non-smokingoffice:6-10timesaccordingtothenumberofstaff; ThemaximumairvolumeofCTBis25m³/min. TobaccoOffice:10-15timesaccordingtothenumberofstaff; IfCTAisselected,then Hospitalandotherenvironment:Accordingtotheuseandgradeoftheroom,take10-15times; Bar,meetingroom:15-20times. Examples: Numberofairpurificationsterilizationmachine= 70m 3/min 14m'/min = 5 In an office with an area of 5m × 7m and a height of 2.6m, the average office staff does not exceed 5 people.HowmanyCTAdoyouneedtoinstall? 05 FiveCTAairpurifiersneedtobeinstalled. 06 Air Cleaner equipment expert Air Cleaner equipment expert IfyouchooseCTBairpurificationsterilizationmachine,then 70m 3/min Numberofsterilizationmachines= 25m'/min = 2.8 Needtoinstall2.8sets,take3CTBairpurificationsterilizationmachines. 4.3.1Unpacking: ! Warning::1.Thebodymayhavesharpedges,whichmaycauseinjurytothehumanbody. 2.Wearprotectivegloveswhenholdingtheelectronicdustcollectionunitorfilter. Unpackingorder: ①OpenthetopcoverofthepackingboxandtakeoutthepaperboxwiththegridpanelandPre-filterandrear 4.2Selectionofinstallationlocation: filters. ②Takeouttheelectronicdustcollectionunitfromthepurifierbody. CTAandCTBairpurificationandsterilizationmachinesareinstalledhorizontallyandcanbeinstalledin ③Removetheairpurifierfromtheouterpackagingbox,unscrewanddiscardthefourscrewsonthebackof anysuspendedceilingenvironment.Thecorrectselectionoftheinstallationlocationwilldirectlyaffectthe thepurifier(tearthestickerinoriginalplace),Inordertomakethemotoroffanfloatandhang,itcanreduce purificationeffect,sothefollowingfactorsshouldbenotedwhenchoosingtheinstallationlocation: Forbestresults,installtheairpurifierclosetothesourceofpollution. Itmustbeensuredthatthepurifiedairdischargedfromtheairpurifiercanenhancetheairflowpatternin the area being cleaned. For example, the purified air discharged from the air purification sterilization machinemustnotinterferewiththeairflowfromthecentralairconditioningsystem. For example, when multiple purification sterilization machines are installed in a room, the purification airflowsdischargedfromeachpurificationandsterilizationmachinemustnotinterferewitheachother,or thedirectionoftheexhaustportofonepurificationsterilizationmachineshouldnotbedirectedtotheother Airinletofthepurificationsterilizationmachine. The shape of the room, the location of the central air-conditioning entrance and exit, architectural thegenerationofnoise. ④Takeoutrelevantattachmentsandrelateddocuments. ⑤Before discarding the packaging materials, please carefully verify whether the relevant accessories and documentsareconsistentwiththequantitygiveninthemanual. 4.3.2Installationsteps ! CTA and CTB are heavy equipment. If it is not strengthened during installation,it is easy to cause structuraldeformation,oreventhewholefalls,resultinginpersonalinjuryanddevicedamage. characteristics and the obstacles of the ceiling are all factors that are considered when choosing the best solution. ①Removetheceilingsheetwherethepurificationsterilizationmachinewillbeinstalled.Thereisaheightof atleast365mmbetweentheroofceilingandthesuspendedceiling,whichcanprovidefreespaceof610× 610mm.Removeallobstaclessuchaspipesandpipelineswithin610×610mm. 4.3Installationprocedure: ②Fixfourexpansionscrewsontheroofceilingdirectlyabovethehangingceilingsheetwheretheairpurifier Beforeinstallingthisproduct: istobeinstalled.(Seethelocationoftheceilinghookintheinstallationdiagram) Please read the instructions carefully. Failure to follow the installation procedures indicated in the ③Usefour12#(forCTA)or10#(forCTB)wiretohangthepurificationandsterilizationmachineonthefour instructionsmayresultindamagetotheproductorendangerpersonalsafety. Checkthegradesgivenontheproductdescriptiontodeterminewhetherthisproductissuitableforyour environment. Theinstallermusthavereceivedrelevanttraining. Afterinstallation,followingtheofferdinstructions,checktheperformanceoftheproductbyatechnician. 07 expansionscrewsthroughthehook(accessory). ④Setfoursidestrips(accessories)onthefoursidesofthepurificationandsterilizationmachine. ⑤Adjust the level adjustment screws on the four hooks separately so that the level of the purification and sterilizationmachineisflushwiththesuspendedceiling. 08 Air Cleaner equipment expert Air Cleaner equipment expert Attention: Thefoursuspensionlinesequallysharetheweightofthepurificationandsterilizationmachine. Whenmakingasuspensionwire,theclosedpartofthewireshouldbetwistedatleastfourtimes. ⑥Withpowercord: CTAandCTBuse220V50Hzsingle-phasethree-wirepowerdistributionmethod. 楼板 ! Warning:Theshelloftheairpurificationsterilizermustbegrounded,otherwisetherewillbeariskof electricshock. The power distribution line of the air purification sterilization machine should have an independent powerdistributionswitch. If the lighting distribution line is borrowed, the distribution switch of the air purification sterilization 天花板膨胀螺丝 悬吊丝杆 悬吊丝杆 固定螺⺟ machineshouldbeconnectedinparallelwiththelightingswitch. Thewiringofdistributionlinesshouldbecarriedoutinaccordancewithrelevantsafetystandards. 螺⺟ 垫⽚ 空⽓净化机 空⽓净化机吊⽿ Passthe3×1.5mm²rubber-coveredthree-corecablefromtheleadholeintothemachine,leavingabout 100mmofwirelengthinthemachine.The"fire","zero"and"ground"wiresofthepowercordarerespectively 垫⽚ 螺⺟ 悬吊天花板 connectedtoL,NandEoftheinternalwiringport. Usethesheath(accessory)tofixthepowercordontheleadhole. Checkthepowerdistributionlineandconfirmthatitiscorrect,thenclosethepowerdistributionswitch of the sterilization machine, and measure the voltage between L-N, L-E and N-E with a multimeter respectively. CTA和CTB安装⽰意图 L-NandL-Evoltageshouldbethemainsvoltage(about220VAC) N-Evoltageshouldbelessthan8VAC IftheL-EvoltageissignificantlylowerthantheL-Nvoltage,thegroundwiremaynotbeconnected ⑦Testmachine: Beforethetestmachine,disconnectthepowerswitchofthepurificationandsterilizationmachine,and measurewiththeresistanceofthemultimeter: Whethertheresistancebetweentheairpurificationsterilizershellandthepowergroundiszero. Whethertheresistancebetweentheshellandthecoronaelectrodeordustcollectorisinfinite. ! Warning: Wearsafetygloveswhentestingthemachinetopreventelectricshock! Donotreachintothemachineduringthetest. 09 09 Air Cleaner equipment expert Teststeps: Withthepowerdistributionswitch,thevoltageattheL-Nterminalis220VAC±15%. Air Cleaner equipment expert 5.OperationofCTAandCTB 5.1Panel Closethemicroswitchundertheconnectionport,thefaninthemachinerotatesatahighspeed,andthe "ON"(green),P.T(yellow)and"WASH"(red)lightsonthepanellightupatthesametime. Under the condition of closing the micro switch, press the "TEST" test button on the panel, "CHECK The GOJEK system is equipped with a state-of-the-art control panel. This advanced control panel allows you to assess the unit status with one quick glance. (yellowlight)flashes,andatthesametimea"pop"voltagedischargesoundisemittedfromthemachine. Under the condition of closing the micro switch, aim the transmitter port of the remote control at the infraredreceivingwindowonthepanel,pressthe"ON/OFF"key,andthe"FAN"(red)lightonthepanelwill flash. Whenthemicroswitchisreleased,alltheindicatorsgooutandthefanstops. ATTENTION Speed Temp. Sterilization Timing R Power Electronic Air Cleaner Speed Timing Sterilization Filter Hum. Accmulatedoperationaltime 1.Mustconnectthepowerlinetothesocketwitheartingline,to preventfromelectricshock; 2.High-voltagedischargedeviceisarrangedinsidetheequipment, topreventpeoplefrombeinginjuredbyhighvoltage; 3.Incaseofpowerfailure,thisequipmentmustbemaintainedafter powercut. . . www szgjhb com Disconnectthepowerdistributionswitch. ⑧ Reinstall the electronic dust collection room. The corona area of the electronic dust collection room shouldfacethedirectionofthegridpanel,andthedustcollectionplateareashouldfacethecentrifugalfan blade. TOUCH KEY DISPIAY AND DESCRIPTION ⑨Insertthefrontandrearfiltersintothegridpanel. ⑩Hangthegridpanelwiththefrontandrearfiltersinstalledonthesidepanelofthepurifier,andinsert the four-core male head of the sensor on the grid plate into the four-core female head suspended in the machine. ⑪Closethegridpanelandlockit. ⑫Recheck: Confirm that the four screws on the back of the purification and sterilization machine have been removed,sothatthefanmotorisfloatingandsuspended. Makesurethattheairflowofthepurificationandsterilizationmachinefacilitatesthegoodcirculationof air. This machine is connected to 110V~240V power (three-phase socket, ground wire). Press Power button, the display screen lights up. Press the ON/OFF button on the control panel, at the moment, the device is under normal operation, and the sterilizing unit device and the negative ion generator have already started working, at this point; Press the Sterilization button, the device stops sterilizing and is in standby mode. You can control the swing direction via air volume via Speed Wind on the control panel and adjust the button. This is a circulating button with three adjustable speed, which are respectively displayed as Low Speed, Medium Speed,High Speed, if you press this button in turn, it will display recurrently. Of course, with different Check whether the grid panel of the purification and sterilization machine is flush with the suspended speed, the noise and purification effect produced by this device vary as well. ceiling, check whether the purification and sterilization machine is suspended in the center of the suspendedceilingsheet,andconfirmthattheweightoftheairpurificationandsterilizationmachinedoes notputmorestressontheceilingskeleton,Otherwiseitwillincreasethenoise. Cleantheinsideandoutsideoftheairpurificationsterilizerandtheinstallationarea. 10 11 Air Cleaner equipment expert 5.2Operation: Air Cleaner equipment expert 6.Maintainence After checking and installing correctly, close the power distribution switch of the air purification CTAandCTBpurificationandsterilizationmachinescanfilteravarietyofparticulatepollutantsfromthe sterilization machine. At this moment, the "P.T" light on the panel of the air purification and sterilization air. These pollutants are adhered to the electronic dust chamber and pre-filter of the purification and sterilization machine, thereby reducing the purification Dust removal efficiency. In order to maintain high machine lights up, the air purification and sterilization machine starts to work, and the fan runs at high performance,itisnecessarytocustomizethemaintenanceofthepurificationandsterilizationmachine Theworkofpurificationandsterilizationmachinemainlyincludesthefollowingtwocontents: speed.Thisisbecausethegassensorintheairpurificationsterilizationmachineneedstobepreheated.If Cleaningofelectronicdustcollectionroomandpre-filter theairpurificationsterilizationmachinehasnotbeenturnedon,about5minuteslater,whenthesensoris Inspectionoftheoperationofthepurificationandsterilizationmachine. preheated,theairpurificationmachinewillautomaticallystopworking. 6.1Cleaningofelectronicdustcollectionroomandpre-filter: Note:Whenthe"P.T"lightison,theremotecontrollercannotchangetheworkingstateofthepurifier. ! Warning Onlyalkalineorneutraldetergentscanbeusedforcleaning,acidicdetergentsarenotallowed. Theemissionwindowoftheremotecontrolisaimedattheinfraredacceptancewindowofthepanelof Theelectronicdustcollectionroomandpre-filterarevulnerable,andcareshouldbetakentoprevent damagetothedevicewhencleaning. theairpurificationandsterilizationmachine,andthe"ON/OFF"keyispressed.The"ON"lightonthepanel lights,thepurificationandsterilizationmachinestartstowork,andthefanrunsatalowspeed. Pressthe"FAN"keytoadjustthefanspeed. Pressthe"TEST"testkeytoconfirmwhetherthepowersupplyisworkingnormally. When holding the electronic dust collector and the front filter, please wear protective gloves to avoid beingcutbysharpmetaledges. Pleasewearprotectiveglovesandprotectivecoverswhenusinghotwaterorstrongdetergents,toavoid burnsorcorrosion. Pressthe"ON/OFF"buttonagaintoturnoffthepurificationandsterilizationmachine. The purification and sterilization machine is regularly shut down and turned on, see the section of 6.1.1Disassemblystepsofelectronicdustcollectionroomandfilter: Turnoffthepowerofthepurificationandsterilizationmachine: remotecontroller. Openthegridpanelonastableworkbenchandremovethepre-filterfromthegridpanel, Useonehandtosupportthelatchbaroftheelectronicdustchamber,andthelatchbarwillberotatedto theopenposition; Usebothhandstopulldownthelatchbarendoftheelectronicdustcollectionroomuntiltheelectrode plateoftheelectronicdustcollectionroomcompletelyleavestheframe; Lift the electronic dust collection room upwards to disengage the hook, and then freely remove the electronicdustcollectionroom; Ifarearfiltersuchasanactivatedcarbonfilterisused,whenitisexcessivelypenetratedbycigarettetar orothergaseouspollutants,removethefailedrearfilterfromthegridpanelandreplaceitwithanewone. Thelifeoftherearfiltervarieswithdifferentmaterialsanddifferentuseenvironments.Theservicelifeofthe rear filter is usually 3-6 months. (The rear filter of some materials can be used repeatedly 2-3 times after washingwithwater.) 12 13 Air Cleaner equipment expert 6.1.2Cleaning Immersetheelectronicdustcollectionroomandpre-filterinalkalineorneutraldetergentsolution.To improvethecleaningeffect,usewarmwaterandkeepshakinguntilthemetalsurfaceoftheelectronicdust Air Cleaner equipment expert Thelatchbarwillberotatedtothelockedposition. Installthepre-filterinthegridpanel. Closeandlockthegridpanel. collection room or pre-filter is restored normal shiny surface,Remove the electronic dust chamber or prefilterfromthecleaningsolutionandrinseitwithcleanwater. If the above method is not sufficient for cleaning, use an ultrasonic cleaner, high-pressure water spray gunorsteam. Dealerscanprovidegeneralcleaningandmaintenancework. Rinsethecleanelectronicdustchamberorpre-filterinacleanplacetodry,Ifyouwanttodry,thedrying temperatureshouldnotexceed80℃. 6.1.3 Reinstalltheelectronicdustchamberandpre-filter: Checkcarefullybeforereinstalling: Arethereanybrokencoronapolewiresandcurveddustcollectorsduringcleaning?Ifyouwanttobend 6.2Maintenanceandinspection: The maintenance content of CTA and CTB purification and sterilization machine can be carried out throughthepanel: Whenthepurificationandsterilizationmachineworksnormally,thepanel"ON"lightison When the ambient air of the air purification sterilization machine is contaminated by smoke, etc., the "P.T"lightison,andthefanrunsathighspeed. Whenthepollutantsareeliminated,thepurificationandsterilizationmachinewillautomaticallyreturn totheoriginalworkingstate. Attention: Iftheweatherwithlowairpressureortheoutsideairisseriouslypolluted,theP.Tlightofthesterilization the bent or skewed dust collector back to the normal position, replace the broken corona pole wires to machineisonandthefanisrunningathighspeed.Thisisnormal.(Atthistime,theremotecontrollercannot maintainnormalperformance. changetheoperationstateofthesterilizationmachine!) Intheabsenceofcoronapolewire,theairpurificationsterilizationmachinecanstillworknormally,but thedustremovalefficiencywilldecrease. Whentherearenomorethanfourwiresornocoronapolewiresatall,the"WASH"lightwillbeon. If the rear filter in the machine cannot filter out various odors in the air, please contact the supplier to replacetherearfilterorreadjustthesensitivityofthegassensor. Ifthe"WASH"lightison,itindicatesthattheelectronicdustcollectionroomistobecleaned. Gentlywipethecoronapolewire. Carefullycheckwhethertheelectronicdustcollectionroomiscompletelydry. If the electronic dust collection room that is not completely dry being installed in the purification and sterilization machine,an arc line or a short circuit in the dust collection room may occur. In this case, the negative ion air purification and sterilization machine can still work normally, but the "CHECK" light is on, andthenegativeionairpurificationandsterilizationmachinedoesnothavetheeffectofpurifyingtheair. Confirmthattheelectrodeplateoftheelectronicdustcollectionroomshouldfacethesideofthelatch bar,andthearrowdirectionoftheairflowoftheelectronicdustcollectionroomshouldpointtothefan(that is,thedustcollectionplatepointstothefan). Electronicdustchamberinstallation: Firstremovethedustfromtheframe. Usetwohandstoliftuptheelectronicdustcollectingroom,inserttheendwithoutelectrodeplateinto theframeoftheelectronicdustcollectingroomandhookitwiththehook.Usetwohandstolifttheendofthe electronicdustcollectionroomwiththeelectronicboarduntiltheelectrodeoftheelectronicdustcollection roommatchestheelectrodeintheframe. Attention: If there are no more than four corona electrode wires in an electronic dust collection room or a dust collectionroom,the"WASH"lightwillalsobeon. Ifyouneedtocheckwhetherthehigh-voltagepowersupplyofthesterilizerisworkingnormaly,pressthe ~TESTbuttononthepanel.Ifyoucanhearthearcdischargesound,itindicatesthatthehigh-voltagepower supplyisworkingnormally.Atthistime,the"CHECK"lightison,otherwisethehigh-voltagepowersupplyis notworkingnormaly. Attention: Inthecasewheretheelectronicdustcollectionroomiswet,theelectronicdustcollectionroomisshortcircuitedduetohighvoltage.The"CHECK"lightwillalsobeon. If the grid panel is not properly closed, the purification and sterilization machine cannot work because thelinkageswitchisnotclosed.Atthistime,closethegridpanelagainorreadjustthelinkageleverofthe linkageswitch. Press the "ON / OFF" or "FAN" button in the remote controller,the upper part of the remote controller Note:Poorcontactoftheelectrodeplateswillcauseanarcbetweentheelectrodes,andevenmaketheelectronic dustcollectionroomwithouthighvoltageelectricity,losingthenormaldustremovaleffectoftheelectronic dustcollectionroom.Atthistime,the"WASH"lightwillbeon. 14 display“ ”(transmit)doesnotflash,orthe"FAN"lightonthepanelofthesterilizationmachinedoesnot flash. It may be because the internal battery of the remote controller is exhausted,replace with new batteries. 15 Air Cleaner equipment expert Air Cleaner equipment expert 8.Diagram 7.Remotecontroller CTAschematicstructure 4 3 Use the Remote Control to: 5 6 7 1 R Electr Speed onic Ai W in d S le e p Wind speed adjusting key,It can be divided into three grades: high/middle/low. r Clea ner re I o n ic Tim e A u to 8 2 Resto Man ual S te r il r 9 1、AiroutletHEPAfilter 2、Activatedcarboncotton filterforairoutlet iz e Wind 3、Operationpanel 4、Linkageswitch Blade swaying, currently in standby. 5、Controlunit 6、Fencebridgepanel Restore 10 7、Pre-filter 8、Electronicdustcollectionunit Cancellation of cumulative working hours. 9、Fansystem CTBschematicstructure Sleep 3 Press this button to pause all work on the machine. Auto 4 10、Fuse 5 8 6 7 8 1 1 2 2 Automatic mode Manual Manual mode Ionic Power Machine on or off Timer ON/OFF Machine on or off Sterilize 10 Turn this feature on or off 16 Can work regularly for 1-12 hours 9 Sterilization mode open/close 17 Air Cleaner equipment expert Air Cleaner equipment expert 9.Packinglist 18 No. Name 1 airpurificationandsterilizationmachine 1 1 2 Electronicdustcollectionroom 1 2 3 Gridpanel 1 1 4 Pre-filter 1 2 5 Rearfilter 1 2 6 Hangingfilm 4 4 7 Sidebar 4 4 8 Remotecontroller 1 1 9 Sheath 1 1 10 Manual 1 1 11 Certificateofconformity 1 1 12 Warrantycard 1 1 CTA CTB 19