NCR No Finding HAK 01 Found the quality manual has not been sign QMR and not been approve by General Manager and the Quality Objectives were not measurable Objective Evidence Quality Manual Effective date : 01 Jun 2009 HAK 02 (SDCC/QM/01), Found the MR minutes was not attended by the Top Management, not effectively reviewed as found no discussion on the achievement of the quality objectives and no conclusion has been made on the effectiveness of the system. Objective Evidence Management Review Minutes, dated : 22 January 2009 Action Taken NCR No Finding HAK 03 Found the quality policy in the quality manual has no approval signatory from Top Management. Objective Evidence Quality Manual, (SDCC/QM/01), Effective Date : 01 June 2009 HAK 04 Found there is 1) No monitoring and recording of the internal product temperature 2) No monitoring of personal hygiene of food preparation staff 3) No monitoring of kitchen cleaning Objective Evidence No records that the internal product temperature has been checked prior to deliver to the customer. Action Taken NCR No. HAK 05 Finding Found that :1) There is no mentioned / indication of storage condition of raw material (Frozen, perishable, WIP and chill). 2) There is no monitoring records to show that the hold temperature for hot food has been monitored during transfer. Objective Evidence 1) In procedure KIT 0024, no indication of raw material storage temperature 2) No records for hold temperature during transfer. Action Taken NCR No Finding KN 01 Found all chillers and cold rooms at all kitchen are not been calibrated. Objective Evidence :There is no calibration record or calibration certificate to show as evidence that the above equipment has been calibrated. NHI 01 Found that the criterion for selection, evaluation and reevaluation of supplier were not adequately established and identify for raw material. Chemical, pest control and calibration suppliers Action Taken NCR No Finding NHI 02 There was no evidence to show that the internal audit has been planned, conducted, effectively implemented and maintained. Objective evidence : 1) For example no evidence to show that the internal audit plan has been established and approved by GM 2) Found that there were no records for audit checklist and internal audit report. Action Taken NCR No Finding NHI 03 1) It was found that several of the document had been changed but the current revision status of the document were not identified 2) The document have not been remain legible and identified 3) The organization had not adequately identified the external documents to control 4) The document was not identified either controlled document or obsolete document Objective evidence : i) ii) iii) iv) v) Quality manual, Section 3; Section 4; Section 8, Rev # 0, date : 1 June 2009 Quality Procedure for Corrective Action (SDCC/QP/GEN/08), Rev #0, Date 1 June 2009 No evidence to show that the Document Change Request Form has been issued for document changes. There was no evidence to shown that the obsolete document has been identified during audit time. Master List document and external origin document was not adequately identified and update. Action Taken NCR No Finding NHI 04 It was found that several of the records were not identified and controlled. Objective evidence : i) Master list of Quality Records was not adequately identified ii) Internal Audit plan, audit checklist and audit report iii) CAR Form. Action Taken NCR No Finding NHI 05 1) It was found that the training program has not been developed and initiated by the organization 2) Found that no evidence to show that the training conducted has been assessed/ evaluate by management/ HOD to see the effectiveness of training Objective evidence : i) No evidence to show that the training plan for year 2009 has been established for all staff. ii) Training evaluation form was not fill up to assess the effectiveness of training conducted iii) Training card for employee # 0468, 0469, 0492 Action Taken NCR No Finding NHI 06 There was no procedure for handling of customer complaints and recorded complaints. The records of customer complaints were not maintained for certain period as required by standard requirements Objective evidence : There was no procedure for handling of customer complaints and recorded complaints NHI 07 Found that the corrective action taken was not adequately addressed for customer complaints, identified root cause and evaluate the action taken to prevent recurrence for following customer complaints. Objective evidence : i) Customer complaint dated 3 Nov 2009 at Chinese Treasure, Guest’s name : Jack Chan ii) Customer complaints dated 20 April 2009 at Chinese Treasure, Guest’s name : BB Ching. Action Taken