PLATE MAGNET FINISHED GROUND LEVEL REFERENCE NUMBER TO BE PERMANENTLY MARKED ON TO CAP. MANHOLE COVER OR SIMILAR 500 MAX FINISHED GROUND LEVEL ACCESS PIPE SPIDER MAGNETS SOIL 100 MIN GROUT 200mm BOREHOLE 20 DIA. STEEL ROD NON-METALLIC SLEEVE 25mm THK MILD STEEL PLATE MIN. DIMENSIONS 500x500mm ORIGINAL GROUND LEVEL 500 SETTLEMENT MARKER DATUM MAGNET FIXED IN PLACE BY SET SCREWS BOTT. CAP OF ACCESS PIPE MAGNETIC SETTLEMENT GAUGE REFERENCE NUMBER TO BE PERMANENTLY MARKED ONTO CAP/STEEL BARREL. MANHOLE COVER OR SIMILAR FINISHED GROUND LEVEL REFERENCE NUMBER TO BE PERMANENTLY MARKED ONTO CAP/STEEL BARREL. LOCKABLE SCREW CAP MANHOLE RING OR SIMILAR TILT SENSOR (UNIAXIAL OR BIAXIAL) 50mmØ CAST IRON PIPE FILL ABOVE BASE PLATE TO BE COMPACTED BY HAND OPERATED COMPACTION PLANT TO 95% MDD. ONE DENSITY TEST TO BE UNDER TAKEN FOR EACH 2m LIFT. 300mmØ THIN WALL PIPE SLEEVE GAUGE LENGTH 20mmØ BAR WELDED TO BASE PLATE AND EXTENDED AS FILL IS PLACED CAP STEEL WATER BARREL FINISHED GROUND LEVEL NOT LESS THAN 1mm NOT LESS THAN 200mm FINISHED GROUND AND/OR TOP OF EMBANKMENT DURING FILLING OPERATIONS REFERENCE NUMBER TO BE PERMANENTLY MARKED ONTO CAP/STEEL BARREL. MANHOLE COVER OR SIMILAR AIR VENTS CONCRETE MIX PLACED AFTER INSTALLATION OF STEEL BARREL GAUGE EXTENSION ROD OR TUBE CLAY BENTONITE/CEMENT GROUT BOREHOLE WHEEL ASSEMBLY NAVI MUMBAI INTERNATIO COUPLERS NOT LESS THAN 500mm INCLINOMETER CASING U.P.V.C. TUBING POROUS ELEMENT ORINGINAL GROUND AFTER CLEARING AND TOP SOIL STRIPPING. COMPACT EXISTING GROUND BELOW PLATE TO 95% MDD. GROUT CLAY BENTONITE/CEMENT IN BAGS OR BENTONITE PELLETS AS SPECIFIED 1mm SAND FILTER SURROUND CLAY BENTONITE/CEMENT GROUT 500x500x50mm STEEL BASE PLATE ORIGINAL GROUND SETTLEMENT MARKER INCLINOMETER STANDPIPE PIEZOMETER