Uploaded by xqiiedu

Datasheet GDB3-10

advertisement
GCR3-11 | Glass card reader
65
GDB3-10 | Glass door bell
• Glass info panel GDB3-10 is part of a comprehensive series of glass
iNELS control units for guest room management system (GRMS), and
is used to indicate the status of guest requests "Do Not Disturb" and
"Make Up Room".
• Glass RFID card reader GCR3-11 is part of a comprehensive range of
glass iNELS control units and can be advantageously used in all projects, e.g. guest room management system (GRMS).
• GCR3-11 card reader is designed for reading smart cards, which are
intended to enter the hotel room or any other part of the building.
• Thanks to the capacitive touch button, the info panel can also be used
for the function of the bell.
• GCR3-11 supports RFID media with a carrier frequency of 13.56 MHz.
Supported card types MIFARE Ultralight, DESFire 2K (EV1), DESFire 4K
(EV1).
• Glass info panel is a design component of the iNELS system and is
available in elegant black (GDB3-10/B) and white (GDB3-10/W) version.
• Info panel printing is possible to customize to the investor requirements. The room number as well as the logo of the hotel can be also
printed on each component.
• The GCR3-11 is a design component of the iNELS system and is available in elegant black (GCR3-11/B) and white (GCR3-11/ W) variants.
EAN code
GCR3-11/B:
GCR3-11/W:
• Input card reader is the first device of guest room management system (GRMS), with which the hotel guest comes into contact first and
therefore was designed with an emphasis on representative design.
8595188157476
8595188157483
Technical parameters
GCR3-11
Input
Illuminance sensor:
1 ... 100 000 Lx
Buttons
Number of control buttons:
Type:
Indication:
3
Capacitive
Card Type:
Output:
Illuminance sensor:
piezo-changer
Switching voltage:
230V AC/ 30V DC
Switching output:
2000 VA/AC1; 240 W/DC
• GCR3-11 are designed for mounting into an installation box.
3.75 kV, SELV according to EN 60950
8–14 V AC/DC
1x 107
Electrical life AC1:
1x 105
Communication
Installation BUS:
Dissipated power:
Rated current:
Network:
0.5°C from the range
Number of control buttons:
Type:
Indication:
max. 0.5 W
100-130 mA (at 27V DC), from BUS
piezo-changer
Vibration motor
Supply voltage / tolerance:
Dissipated power:
Rated current:
0.5 - 1 mm2
BUS +
BUS -
max. 80 %
-20 .. +55 °C
-30 .. +70 °C
Overvoltage category:
Pollution degree:
Operation position:
IP20
II.
2
on the wall, observing the conditions for correct
installation of the thermostat
Operating temperature:
-20 .. +55 °C
Dimensions and weight
Storing temperature:
-30 .. +70 °C
Dimensions:
Installation:
max. 0.5 W
100-120 mA (at 27V DC), from BUS
Storing temperature:
Installation:
Operation position:
27 V DC, -20 / +10 %
Operating temperature:
max. 80 %
Pollution degree:
BUS
Connection
Relative humidity:
Overvoltage category:
Do Not Disturb, Make Up Room
Tactile output:
Operating conditions
Protection degree:
temperature sensor TC / TZ or *
2x input for free potential contacts
(buttons, PIR etc.).
Coloured illuminated symbol
Acustic output:
Protection degree:
BUS +
BUS -
max. 2.5 mm2/1.5 mm2 with sleeve
1
Capacitive
Operating conditions
27 V DC, -20 / +10 %
terminals, 0.5 - 1 mm2
Connection
1 ... 100 000 Lx
Buttons
Relative humidity:
Connection
Data:
Temperature measurement accuracy:
Terminals:
BUS
Power supply
Supply voltage / tolerance:
-20°C to +120°C
Power supply
Switching frequency
Mechanical life:
• GDB3-10 are designed for mounting into an installation box.
TC/TZ
Temperature measurement range:
Installation BUS:
300 min-1
10 min-1
YES, the connection between
• Individual symbols can be illuminated in one of seven colours - red,
green, blue, yellow, pink, turquoise and white.
Communication
Switching frequency
with rated load:
2x AIN/DIN
by setting 10-bit
• Info panel GDB3-10 is equipped with a sensor for ambient light intensity. Based on information from the sensor it can e.g. switch the lighting circuits in the corridor.
AIN1/DIN1 and AIN2/DIN2
Signalling:
Connection
relay outputs and internal
10 mA / 10 V
Resolution:
0.. +55°C; 0.3°C from the range
• All versions are in the size of the module (94x94 mm) from the line
of luxury switches and sockets LOGUS90 and are therefore fully in line
with the design of frames for the sockets of this series, where you can
just as for the controllers choose white and black glass frames.
Output
20 A/<3s
Insulation voltage between
without load:
Inputs:
• All versions are in the size of the module (94x94 mm) from the line
of luxury switches and sockets LOGUS90 and are therefore fully in line
with the design of frames for the sockets of this series, where you can
just as for the controllers choose white and black glass frames.
Vibration motor
Minimal switched current:
measuring:
Type of external sensor:
1x changeover 8 A / AgSnO2
YES, built-in temperature sensor
Scope and accuracy of temp.
• Reader GCR3-11 is equipped with a sensor for ambient light intensity.
Based on information from the sensor it can e.g. switch the lighting
circuits in the corridor.
Tactile output:
circuits:
Temperature measuring:
External temperature sensor:
Do Not Disturb, Make Up Room
GDB3-10
Inputs
• Reader GCR3-11 is equipped with an 8A relay output with AgSnO2 contact for door lock control.
Acustic output:
Peak current:
Technical parameters
13.56 MHz
MIFARE Ultralight, DESFire 2K (EV1), DESFire 4K (EV1)
• The "Do Not Disturb" or "Make Up Room" statuses can be entered by
the hotel guest from a multi-functional touch panel EHT3, glass card
holder GCH3-31, glass switch buttons GSB3-20/S, GSB3-40/S, GSB360/S or such GSP3-100 glass switch panel.
8595188157261
8595188115728
• Individual symbols can be illuminated in one of seven colours - red,
green, blue, yellow, pink, turquoise and white.
Outputs
Signalling:
• The controller is also equipped with touch button with function of
bell and with two icons to indicate the status of guest requests, e.g.
“Do Not Disturb" and "Make Up Room", whose state guest can set from
multi-function touch panel EHT3, glass card holder GCH3-31, glass
switch buttons GSB3-20/S, GSB3-40/S, GSB3-60/S or such GSP3-100
glass switch panel.
EAN code
GDB3-10/B:
GDB3-10/W:
Coloured illuminated symbol
RFID readers
Supported frequencies:
• Printing is possible to customize to the investor requirements. The
room number as well as the logo of the hotel can be also printed on
each component.
electric door lock
64
IP20
Weight:
into installation box
94 x 94 x 36 mm
154 g
II.
2
any
into installation box
Dimensions and weight
Dimensions:
Weight:
94 x 94 x 36 mm
161 g
* The choice is made in iDM3 for each unit separately.
Download