Uploaded by olocausto

vdocuments.mx sales-training-slides-netsure-501-ac0-actura-flex-48420

advertisement
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
NetSure 501 AC0
Training Slides
Allon Pan
Product Manager, DC Asia-Pacific
Kevin Yang
Design Project Manager, DC Asia-Pacific
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
1/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Agenda

ACTURA Flex 48420 Introduction

Large System Concept

Product Roadmap
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
2/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Applications
-
Mobile base station
-
Small exchange station
-
Satellite communication
-
Data communication
-
……
Generally: Sites requiring DC power with load max 20.4 kW
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
3/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
System Principles
AC Input Terminals
Rectifier AC
Breakers
Rectifiers
Back Board
Control Unit
C Class SPD
Battery 1
BLVD
LLVD
(Optional)
Non-priority Load
Priority load
Battery n
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
4/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Key Benefits

High power and battery density

Front Access


–
Up to 20.4kW and 660Ah in 1 cabinet
–
–
Can be mounted against wall and with cabinets on either side
Minimum floor space required
High flexibility and wide variety of ordering options
–
–
Output power, system: 1.7 – 20.4 kW
Standard or advanced controller
–
–
–
–
–
–
–
Configurable number of distribution circuit breakers, and sizes
Configurable number of battery circuit breakers, and sizes
With or without Priority and Non-Priority Low Voltage Disconnect
Various AC options with/without SPD and AC breakers
1800 or 2000 mm cabinets, 600 and 400mm depths
Single cabinet solution, with or without batteries
Extended battery cabinet available
Based on Global Building Block (Rectifier and Controller)
–
–

Utilizes UL approved rectifier R48-1800
Hot pluggable rectifier and controller (ACU or SCU)
Wide operating range
–
–
–
Input voltage range (85-300Vac)
Input temperature range (-5 to +55C)
Suitable for harsh conditions
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
5/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
High Power and Battery Density, Small Footprint

600 x 600 x 2000mm (WxDxH) cabinet
– Up to 20.4kW (12 x 1700W) + 4 x 165Ah (or 5 x 100Ah) batteries
– Battery shelves adjustable to cater for different battery sizes

600 x 400 x 2000mm (WxDxH) cabinet
– Up to 20.4kW (12 x 1700W) + 5 x 100Ah batteries
– Battery shelves adjustable to cater for different battery sizes

600 x 600 x 1800mm (WxDxH) cabinet
– Up to 20.4kW + 3 x 165Ah (or 4 x 100Ah) batteries
– Battery shelves adjustable to cater for different battery sizes
Value added to Customer:
Save site floor space, save site construction cost
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
6/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Friendly to Maintain and Monitor

Front access

Hot replaceable rectifiers and controllers

User-friendly controller unit with fault alarms and history log

Remote monitoring applicable
EXMG,ENEC
PSMS
SiteScan
EEM protocol
Web Browser
Nform
HTTP, SNMP
TCP/I
P
SM-BAT
RS485
SM-IO
Site
SM-AC
ACU
Value added to Customer:
Save maintaining time, save site visiting labour
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
7/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Flexible and Scalable Power System
3 cabinet sizes
600W x 600D x 2000H (mm)
600W x 400D x 2000H (mm)
600W x 600D x 1800H (mm)
Batteries, 12V front terminal
In 600 deep, 2000 high
5 x 100 Ah (500 Ah)
4 x 165 Ah (660 Ah)
In 400 deep, 2000 high
5 x 100 Ah (500 Ah)
In 600 deep, 1800 high
4 x 100 Ah (400 Ah)
3 x 165 Ah (495 Ah)
2m cabinet
2m cabinet
1.8 cabinet
1.7 kW
1.8m
cabinet
20.4 kW
Value added to Customer:
Fullfill various demand of capacity and functionality
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
8/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Wide AC Input Range
R48-1800 Advantages:


DC power output at 85 – 300 Vac input
Non-destructive 0 – 415 Vac input
Value added to Customer:
No need to over-dimension the power system in order to
cope with input voltage / output voltage peaks
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
9/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Wide Operating Temperature Range
R48-1800 Advantages:


Rectifier Operating temperature: -40°C ~ 80°C
System Operating temperature: -5°C ~ 55°C
Value added to Customer:
No need to over-dimension the power system in order to
cope with temperature
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
10/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Emerson Brand Total Solution of Surge Protection
II/D SPD Built-in Rectifier
Rectifier
AC Input
I/B
SPD
5~10m
AC power
distribution
unit
II/C
SPD
DC power
distribution
unit
Rectifier
Dist.
SPD
Rectifier
Battery
group
Standard
control unit
ANYGUARD
Emerson Brand
Note:
I, II, III are based on IEC standard
B, C, D are based on German VDE standard
48V Output
RS232
RJ11
MODEM
DINVED0675 -6: 1989 -11 (draft)
RJ11
PSTN
Remote monitoring host
SPD
Value added to Customer:
Protect investment, reduce down time
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
11/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Main and Extension Battery cabinets
Value added to Customer:
Double the batteries to sustain long time AC fault
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
12/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
System Components
Extension Distribution Unit (DU)
Multi Function Unit (MFU)
Rectifier sub-rack
SCU (M500D, M501D) and ACU (M800D)
Rectifier (R48-1800)
Excellence, Duration
Cabinet
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
13/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Multi Function Unit (MFU)





Maximum 19 positions, configurable for AC breakers, SPD and
High/Low Priority Load breakers (max 10 load breakers)
Front access AC input terminals
3 x 70mm2 and 7 x 25mm2 positive load connections
Optional BLVD and LLVD contactors
ACU or SCU controller options
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
14/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
MFU Configuration
No.
Component
Description
1
AC Main
Single Phase 220, Phase-phase 220V,
Three Phase 220/380V,
Single feed
2
SPD
AC side 8/20 us 20kA, ±5 times /
AC side 8/20 us 40kA, 1 time
3
AC input cable
Max 35sq mm
4
AC input terminals
Rating Current 125A
5
Rectifier AC input MCB
Rating Current 16A
6
BLVD contactor
200A or 400A optional
7
LLVD contactor
200A or 400A optional
8
9
Shunt
Cable to battery
500A/75mV
25sq mm
10
Battery MCB
100A / 200A MCB (up to 5 battery MCBs)
11
Load MCB
Selected according to user’s requirement
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
15/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Multi Function Unit Detail
Alarm Connector Board
Controller Slot
Back Board
Load breakers
Positive Common
LLVD Negative
AC Input breakers
LLVD
Surge Protection
BLVD Negative
AC Input terminals
BLVD
Battery Negative
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
16/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Extension Distribution Unit (DU)




3U high, 23” wide
Maximum 28 positions – configurable for Low or High Priority Load
breakers (18mm type)
7 x 70mm2 and 32 x 25mm2 positive common connections
Circuit breaker alarm monitoring
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
17/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Distribution Unit Detail
Load Breakers
Cage Clamp
Terminal
LLVD Bus Bar
BLVD Bus Bar
CB Alarm Board
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
18/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Rectifiers: R48-1800
•DSP (Digital Signaling Processor)
•Means fewer components, optimized operation and
active load sharing for increased reliability
•Compliant with global standards
•Delivers quality, performance and reliability no matter
what the application or location demands
•High
efficiency,
up consumption
to 91%
•Reduces
power
for lower operating costs
•Hot pluggable
•Facilitates future extensions
•Wide input voltage range (85V to 300V)
•Operates in the most demanding environments where
input voltage changes
•Wide temperature operating range (-40C to +80C)
•Meets the harshest climatic environment requirements
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
19/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Rectifier Technical Data
Input voltage window
Non-destructive voltage
Power factor
THD
Output voltage
Output power
Max output current
Efficiency
Temperature range
RH (non-condensing)
EMC
Safety
Dimensions
Weight
85R48-1800
to 300 VAC
0 to 415 VAC
0.99
<5%
-42 to -58 VDC
1700 W
35.4 A
91%
-40 to +80 C
0 to 95%
EN 300 386:2001, class B
IEC / EN / UL 60950
86H (2U) x 84.5W (2U) x 272D (mm)
1.8 kg
Data sheet of
Rectifier
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
Telecom Sales Training – Sep 29
20/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Rectifier Lay-Out
Input Socket
Power Indicator
Protection indicator
Alarm indicator
Bolt
Handle
Output Socket
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
21/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
BCU - Battery Connection Unit
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
22/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
BCU Details
Enclosure
Up to 5 x 100A
Or
Battery MCB
Up to 5 x 200A
-48V DC Bus
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
23/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Controller – SCU / ACU
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
24/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
ACU&SCU Hardware Interfaces
Ethernet, RJ 45
1 RS 232 DB 9 port
HTTP, SNMP, FTP
1 RS 232 for Console
8 outgoing
alarm/control
relays
3 LED’s to
1 RS 485 for
indicate alarms and
operation conditions
communication
with SM
8 digital inputs for generic
alarms
2 Temp. sensor
inputs
Bi-BLVD
Bi-LLVD
DC power input
19-60 V
10 Digital in for DU
Connector board
4 Digital in for BCU
2 LVD for disconnect of batteries and load
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
25/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Connector Board
User
interface
board
- 8 outgoing
alarm
relay contacts
- 8 incoming digital inputs
- 2 temperature sensor inputs
- 2 RS232 (for modem / PC interface)
- 1 Ethernet port (used with ACU only)
- 1 RS485 port (used with ACU only)
Connector board
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
26/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Back Board
Interfaces
theCB
controller
to the power supply system
- Distribution
alarm inputs
- Battery CB alarm inputs
- System shunt
- System voltage measurement
- CAN bus for rectifier communication
- LLVD & BLVD contactor driver outputs
Back Board
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
27/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
SCU / ACU Features
Function
SCU
ACU
Yes (128X64)
No
Yes (128X64)
Yes
SNMP
No
DC Power MIB
EEM protocol
Yes
Yes
SOC/TPE protocol
Yes
Yes
YDN 23 protocol
Active Alarms on LCD
Yes
Yes
No
Yes
Alarm History
Yes 200
Yes 400
Statistics/Logs
Basic battery log
Advanced battery &
Events log
AND/OR/XOR
../NOT/TIMER/LEVEL
Firmware download
No
Yes TELNET
Energy Savings
No
Yes
Yes 8
Yes 8
Power Split
No
Yes
SM Support
No
Yes 13 SM Units
Local Display
Web
PLC function
Alarm relay output
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
28/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
SCU / ACU Features, Continued
Function
SCU
ACU
Temp charging
Boost charging
Yes
Yes
Yes
Yes
Battery current limitation
Yes
Yes
Const current/Volt level
Const current/Volt level
Battery prediction
Yes
Yes
Battery tables
10
10
Current walk in settings
Yes
Yes
External alarm inputs
8
8
LVD
2
2
System Voltage
Yes
Yes
Battery Currents
Yes 2
Yes 2
Battery Fuse Input
Distribution Alarm Inputs
4
10
4
10
Distribution Currents
1
1
Temperature Sensor
2
2
Battery discharge test
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
29/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Market Introduction Milestones
August
Internal Launch
Datasheet
Pricing
Presentation
M1
July
August
November 15th
First deliveries
M2
M3
September
October
M3
November
September 1st
Available to offer to
October 1st
Accept first
customers
orders
Mass
Prototypes
Pilot
Production
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
30/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Marketing Collateral
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
31/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Product Positioning
6.4 + 3.2kW
330Ah batteries
Open Rack (1.6m)
Ext DU optional
8.5 + 1.7kW
495Ah batteries
Cabinet (1.8m)
Ext DU optional
e
c
i
r
P
Flex 48420
(Max)
Flex 48330
Flex 48420
(Basic)
12.8 + 3.2kW
660Ah batteries
18.7 + 1.7kW
660Ah batteries
Cabinet (2m)
Cabinet
(2m)
Ext
DU optional
Optima 48200
Capacity / Features
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
32/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Agenda

Small BTS Introduction
Large System Concept

Product Roadmap

Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
33/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Goals of Program


Develop a cost effective, high performance
replacement for ACTURA Flex 48800 and Silcar
LPS and MPS systems
Combine all products into a single platform if
possible,
improving
production
and support
logistics and
reducing
cost

Utilise new 100A rectifier GBB and Advanced
Control Unit (ACU)
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
34/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Large System Concept





Replacement for Flex 48800
and existing LPS and MPS
Maximum 48 x 100A rectifier
modules (max 5760A @ 48V)
Minimum 1, Maximum 8
cabinets (Rectifier and DU)
Maximum 32 battery breakers /
fuses
LVD external to cabinet (at
batteries), or using trip coils
(manual reset) on BCB in
cabinets
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
35/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Two basic cabinet types
Rectifier Cabinet
Distribution Cabinet
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
36/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Large System Rect Cabinet - Constraints



Maximum 16 rectifier modules per rectifier cabinet
Maximum 4 x NT4 fuses or NS250 breakers per cabinet
(battery or load)
Built in AC distribution in rectifier cabinet
– Max 2 AC DU, each with AC input terminals and 8 3-pole rectifier
breakers
– A + B AC feed possible

2 x 3U DC CB DU or 1 x 6U DC fuse DU per rectifier
cabinet
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
37/63
8/3/2019
Positive Bar
Rectifier Cabinet
Layout
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
NT4 Fuse /
NS250 breaker
Battery Shunt
Negative Bar
2 x 3U DU/
1 x 6U DU
ACU
2 x AC DU
Maximum 16 rectifier
modules per rectifier cabinet
Maximum 4 x NT4 fuses or
NS250 breakers per cabinet
(battery or load)
Built in AC distribution in
rectifier cabinet
–Max 2 AC DU, each with
AC input terminals and 8 3pole rectifier breakers
–A + B AC feed possible
Rectifiers
2
x 3U
DU
or 1 x 6U
DC
fuseDC
DUCB
per
rectifier
cabinet
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
38/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Large System DU Cabinet - Constraints


Maximum 4 x NT4 fuses or NS250 breakers per
cabinet (battery or load)
Possibility to mount the following:
– 6-8U high DU with 6 x NT2 fuses
– 3 U high DU with up to 35 HOD breakers (CBI)
– 3U high DU with up to 28 LOD breakers (ABB)
– Possible to plug in or add DUs in field?
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
39/63
8/3/2019
Positive Bar
Distribution
Cabinet Layout
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
NT4 Fuse /
NS250 breaker
Battery Shunt
Negative Bar
Maximum 4 x NT4 fuses or
NS250 breakers per
cabinet (battery or load)
Possibility to mount the
following:
–
–
3 x 6U DU, or
6 x 3U DU, or
combination
–
–
6-8U high DU with 6 x
NT2 fuses
3 U high DU with up to
35 HOD breakers
(CBI)
3U high DU with up to
28 LOD breakers
(ABB)
Possible to plug in or
add DUs in field?
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
40/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
High Ohmic Distribution Unit




Up to 35 breakers per
DU (3U high)
15A or 2 pole 30A High
Ohmic breakers
Up to 2 x DU per
Rectifier Cabinet
Up to 6 x DU per
Distribution Cabinet
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
41/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Low Ohmic Distribution Unit




3U high, 23” wide
Maximum 28 positions – configurable for Low or High
Priority Load breakers (18mm type)
Ratings 3A to 100A (18mm), 125A (27mm)
7 x 70mm2 and 32 x 25mm2 positive common
connections
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
42/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Fuse Distribution Unit

6U high, 23” wide

Maximum 6 Fuses (NT2) – up to 630A

Positive Connections via Positive Common Bar
at top of cabinet
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
43/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Typical 2 cabinet layout
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
44/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Example 3 cabinet layouts
2 Rec + 1 DU
2 DU + 1 Rec
3 Rec
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
45/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Example 5 cabinet layouts…
2 Rec + 3 DU
3 Rec + 2 DU
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
46/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Example 5 cabinet layouts
5 Rec
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
47/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
LPS Implementation
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
48/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
MPS Implementation
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
49/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Large Rectifier R48-5800
Faceplate
Horizontal in 23” inch cabinet
Rectifier R48-5800
Vertical in 23” inch cabinet
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
50/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Rectifier Technical Data
R48-5800
Product Name
Input voltage window
260 to 530 VAC (Full power from 304 to 530 Vac)
Non-destructive voltage
0 to 600 VAC
Power factor
0.99
THD
<5%
Output voltage
-42 to -58 VDC
Output power
5800 W
Max output current
121A
Efficiency
92%
Temperature range
-40 to +65 C
RH (non-condensing)
EMC
Safety
Dimensions
0 to 95%
EN 300 386:2005, class B & FCC part 15, class B
IEC / EN / UL 60950
244W (5.5U) x 88H (2U) x 380D (mm)
Weight
8 kg
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
51/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
ACU (Advanced Controller Unit)
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
52/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
ACU Technical Data – Part I
Function
ACU
Local Display
Yes (128X64)
Web
Yes
SNMP
DC Power MIB
EEM protocol
Yes
SOC/TPE protocol
Yes
YDN 23 protocol
Active Alarms on LCD
Yes
Yes
Alarm History
Yes 400
Statistics/Logs
Advanced battery & Events log
PLC function
AND/OR/XOR/NOT/TIMER/LEVEL
Firmware download
Energy Savings
Alarm relay output
Yes TELNET
Yes
Yes 8
Power Split
Yes
SM Support
Yes 13 SM Units
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
53/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
ACU Technical Data – Part II
Function
ACU
Temp charging
Yes
Boost charging
Yes
Battery current limitation
Yes
Battery discharge test
Const current/Volt level
Battery prediction
Yes
Battery tables
Current walk in settings
10
Yes
External alarm inputs
8
LVD
2
System Voltage
Battery Currents
Battery Fuse Input
Yes
Yes 2
4
Distribution Alarm Inputs
10
Distribution Currents
1
Temperature Sensor
2
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
54/63
8/3/2019
Agenda
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)

Small BTS Introduction
Large System Concept

Product Roadmap

Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
55/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Road Map – Micro / Mini
FY05
FY06
Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 Q1
FY07
Q2 Q3
Q4
FY08
H1 H2
FY09
H1 H2
GIE 4805/GIE 4815 5/15A
Mini48 300W 2x3U
P
A
P
N
E
Actura 48 201 (ph1)
Actura 48 201 (ph2)
400/800W 1x2U
Actura 48 101
300W 1.5x2U
*
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
56/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Mini System Lineup
ACTURA 48101
ACTURA 48201
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
57/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Roadmap - Small
Cost
Control Rect.
P
A
P
N
E
C
P
N
E
Actura Optima 48130
Menu
PS 48300/ 48350/48160
Q1
FY05
Q2 Q3
Q4
Q1
FY06
Q2 Q3
Q1
FY07
Q2 Q3
Q4
FY08
H1 H2
FY09
H1 H2
1200W
1500W 3x2U
25A
Actura Flex 48420
PS 48120&300/1800
PS 48100-2/25
PS 48300-3/30
Q4
1700W 2x2U
1740W 2x2U
1450W, 3x2U
1740W, 3x2U
PS 48120&300/1800
1740W 2x2U
LTB
GBB avail.
GBB system
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
58/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Small System Lineup
PS48120 / PS48300
Flex 48420
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
59/63
8/3/2019
Road Map – Medium
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Q1
FY05
Q2 Q3
Q4
Q1
FY06
Q2 Q3
Q4
Q1
FY07
Q2 Q3
Q4
FY08
H1 H2
FY09
H1 H2
Actura 4827 2700W 2x19"
Actura F 2700W 2x19"
Silcar MPS/LPS 2700W 2x19"
PS48400/48600 50A
Actura Flex 48330
2900W 2x3U
PS48400/48600
Silcar MPS/LPS
Low Cost BTS
29000W 2x2U
LTB
GBB avail.
ENPC
EES
GBB system
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
60/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Medium System Lineup
ACTURA Flex 48330
ACTURA Optima 48200
PS48600
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
61/63
8/3/2019
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
Roadmap - Large
Cost
Control Rect.
Actura 4860
PS 481500
FY05
FY06
FY07
FY08
Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 H1 H2
6000W 4x19"
FY09
H1 H2
Partly replaced by 50A
5800W 2x19",
Flex 481000
100A 2x5,5U
PS481000-6/100
100A 2x5,5U
Telecom Sales Training – Sep 29
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
62/63
8/3/2019
Large System Lineup
Sales Training Slides - NetSure 501 AC0 (Actura Flex 48420)
PS481000-6
http://slidepdf.com/reader/full/sales-training-slides-netsure-501-ac0-actura-flex-48420
New Large (AP)
63/63
Download