Product Catalogue Environment and quality policy Draka Keila Cables Ltd. wishes to gain satisfaction of the customers, employees and owners without damaging of environment. In Draka Keila Cables Ltd. the decisions are made, which allow to develop the company and to save environment at the same time and on the assumption of this principle continuously to improve the system of management. In Draka Keila Cables Ltd. there is used the multistage program of the quality control, which covers production process from development of the cables, purchasing of raw materials and production of installation and power cables to the documentation of supplemental examinations and tests. The quality and environmental management system of Draka Keila Cables Ltd. has appraised and approved by Lloyd’s Register Quality Assurance Limited, which performs regular audits according to standard of quality system ISO 9001 and ISO 14001. Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General information. . . . . . . . . . . . . . . . . . . . . . . . . . 3 Basic cable data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power cables ACSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 HK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 AS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 AXMK-PLUS and XMK-PLUS 1-core. . . . . . . . . . . . 13 AXPK-PLUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 AXPK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 EMC-Line 1 kV (IFSI). . . . . . . . . . . . . . . . . . . . . . . . . 18 AMCMK 3 1/2-core . . . . . . . . . . . . . . . . . . . . . . . . . . 20 AMCMK 4 1/2-core. . . . . . . . . . . . . . . . . . . . . . . . . . 22 MCMK 3-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 MCMK 4-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 MCMK 5-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 MCCMK 4-core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 MCCMK 5-core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 MCMK 3 1/2-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 MCMK 4 1/2-core. . . . . . . . . . . . . . . . . . . . . . . . . . . 32 MCMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 ARLC Aluminium Road Lighting Cable. . . . . . . . . 35 EX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 AMKA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 AHXAMK-W 6/10 (12) kV. . . . . . . . . . . . . . . . . . . . . 38 AHXAMK-W 12/20 (24) kV. . . . . . . . . . . . . . . . . . . . 39 AXLJ-TT 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 AXLJ-TT 14/24 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . 41 AXLJ-TTCL TSLF 14/24 kV. . . . . . . . . . . . . . . . . . . 42 AXLJ-TT 7/12 kV (3-core). . . . . . . . . . . . . . . . . . . . . 43 AXLJ-TT 14/24 kV (3-core). . . . . . . . . . . . . . . . . . . 44 AXLJ-RMF 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . 45 AXLJ-RMF 14/24 kV. . . . . . . . . . . . . . . . . . . . . . . . . 46 AXQJ-RMF 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . 47 AXQJ-RMF 14/24 kV. . . . . . . . . . . . . . . . . . . . . . . . . 48 AXQJ-F 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 AXQJ-F 14/24 kV . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 PAS-W 20 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Installation cables and wires PL / ML / H07V-U. . . . . . . . . . . . . . . . . . . . . . . . . . . 53 PK / MK / H07V-R . . . . . . . . . . . . . . . . . . . . . . . . . . 54 MK 90 / H07V2-R. . . . . . . . . . . . . . . . . . . . . . . . . . . 55 MKEM 90 / H07V2-K. . . . . . . . . . . . . . . . . . . . . . . . 56 MMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 EKLK 450/750 V . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 PPJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 MSK / H05VV-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 PROFIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Automation, data and telecommunication cables JAMAK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JAMAK ARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NOMAK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KLMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PULS 2,5 75V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VMOHBU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H05RN-F; RDO/05RN-F 300/500 V. . . . . . . . . . . DRAKAFLEX H07RN-F 450/750 V. . . . . . . . . . . . 62 63 64 65 66 67 68 69 70 Halogen-fee and fire resistant cables DRAKAFLEX-TARMO H07BN4-F 450/750 V LSZH . . . . . . . . . . . . . . . . . 72 HULT(FLEX) LSOH FB 90 0,6/1 kV . . . . . . . . . . . . 74 HULT(FLEX) LSOH FB 30/60 0,6/1 kV . . . . . . . . . 75 Signal cable type 2300 FB 30 (mbzh). . . . . . . . . .76 Signal cable type 2300 FB 90 (mbzh) . . . . . . . . . 78 Draka SF/UTP Cat."5" FB 90 (mbzh). . . . . . . . . . . 80 BI(c) 250V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 BFSI-EMC 1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 HULT(FLEX) LSOH 0,6/1 kV. . . . . . . . . . . . . . . . . . 83 EQQ-Light 300/500 V. . . . . . . . . . . . . . . . . . . . . . . 84 EQLQ 450/750 V. . . . . . . . . . . . . . . . . . . . . . . . . . . 85 FQLQ 450/750 V. . . . . . . . . . . . . . . . . . . . . . . . . . . 86 AXQJ 0,6/1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 EXQJ 0,6/1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 FXQJ 0,6/1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Drums Drum handling guide. . . . . . . . . . . . . . . . . . . . . . . . 90 Drum dimensions and weights. . . . . . . . . . . . . . . . 92 Introduction Draka Keila Cables was established in 1992. Company’s equity holders are Draka NK Cables Ltd. (former Nokia Cables), with 66%, and an Estonian electrical equipment producing company AS Harju Elekter with 34%. Through Draka NK Cables Keila Kaabel belongs to DRAKA Holding, one of the biggest cable producers in the world. The group consists of 59 entities located in 24 countries in Europe, Americas and Asia. The headquarter and manufacturing facilities of Draka Keila Cables are located on territory of AS Harju Elekter in Keila, Estonia. Our major markets are Baltic countries. Representative offices have been set up in Riga and Vilnius to ensure proper communication with our customers in Latvia and Lithuania. Draka Keila Cables is focused on the three main product groups: low-voltage and special purpose cables, power cables and telecommunication cables. Our goal is to provide customers the best solutions for transmission of energy and information. Cables are produced in a wide range, according to needs of customers and current standards. Products are certified in internationally recognized certification authority SGS-FIMKO. The quality of our products is assured by modern technology, high-quality raw material and well-trained professionals. Company’s quality management system was declared to be in accordance with of ISO 9001 by LRQA in 1998. In 2001 Keila Kaabel environmental management system acquired certificate of accordance with the requirements of ISO 14 001. Draka Keila Cables is a fast growing manufacturing company, the key to our success is ability to respond flexibly to rapidly changing business environment. Draka Keila Cables is open for co-operation possibilities coming from east as well as west. Draka and Prysmian joined to form global Prysmian Group A merger of two large cable corporations formed the Prysmian Group, the world’s largest cable corporation, having active representations in 50 countries and a total of 90 factories with more than 20,000 employees. Both Draka and Prysmian are globally strong brands and have strong sides, so the brands will remain in parallel existence and development in the future. As a result of the merger, our product range is extended because both companies have numerous unique products that complement the previous product ranges of each other. Also, the availability and delivery security of products will improve. We can now serve our customers with the know-how and product development of both corporations, and we can better involve our customers in product and service development, taking into account the local specifics. 2 | Draka Keila Cables Product Catalogue General information Standards Rated voltage All conductors and cables in this catalogue are manufactured according to valid international standards. The cable meets the requirements of the standards mentioned in the cable description. The table below gives the common rated voltage for cables according to the international standard IEC 60038. Special conductors and cables Also other types of conductors and cables, not included in this catalogue, are available by Draka, as agreed with the client. Catalogue information The dimensions and weights are nominal values. Due to continuous product research and development the listed data is subject to change. Our product development is a continuous process. We reserve the right to change the data without prior notice. U0 U Um Rated voltage between the conductor and the earth Rated voltage between conductors maximum operating voltage in any part of the network, excluding temporary fluctuations during switching, breaking and faults peak value of the impulse withstand voltage between each conductor and the earth Up U0/U Um Up kV kV kV 0,6/1 1,2 - 3,6/6 7,2 - 6/10 12 75 12/20 24 125 18/30 36 170 20,3/35 26/45 42 52 198 250 Basic cable data Minimum bending radius Maximum pulling force • Minimum permissible bending radius during cable pulling are given in section Basic cable data. • • Values may be reduced by about 30 % in the final installation, if the cables are bent carefully and evenly only once. – cables with aluminium conductors . . . . . . . . . . 10 to 15 N/mm2 – cables with copper conductors . . . . . . . . . . . . . 10 to 20 N/mm2 multiplied by the added-up cross section of the inner conductors, but max. value in both cases is 8,500 N. Maximum permissible pulling tension when pulling by the cable grip is given in the basic data on each cable type • Pulling by the eye attached to the conductor – cables with aluminium conductors . . . . . . . . . . . . . . . 50 N/mm2 – cables with copper conductors . . . . . . . . . . . . . . . . . 100 N/mm2 however not more than about 20,000 N. • Product Catalogue Pulling by the armouring wires 130 N/mm2, multiplied by the cross section of the armouring Draka Keila Cables | 3 Basic cable data Minimum permissible installation temperature Minimum permissible cable temperature during laying: while laying power cables, the temperature of cables should not be below the following values: The earth fault current increases relatively as much as the capacitance. The charging currents and earth fault currents have been calculated at a frequency of 50 Hz. Inductance • Plastic insulated power cables < 1 kV – PVC-sheathed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —15˚C Inductance given for each cable type is approximate. Assumptions for the inductance of single core cables: • XLPE insulated power cables > 1 kV to < 30 kV – PVC-sheathed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —5˚C – PE-sheathed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —20˚C • • XLPE insulated power cables > 30 kV – PVC-sheathed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —5˚C – PE-sheathed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —15˚C At lower temperature the cables must be adequately warmed up beforehand. This can be done by storing in a heated area for several days or by means of special hot air equipment. Technical data Resistance The next pages give for each cable type the maximum direct current resistance (DC-resistance) of the conductors permitted by the standard at a temperature of +20˚C. The DC-resistances of metal sheaths and screens are computed ratings. The additional losses caused by the skin and proximity effects are taken into account in the alternating current resistances (AC-resistance) with the following assumptions: • • • • Flat formation: the clear space between the cables = the external diameter of cable Trefoil formation: the cables touch one another Current ratings Basic assumptions: 1. Maximum permissible temperature of the conductor in continuous use: • PVC insulated 1 kV cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . +70˚C • XLPE insulated cables (see further details). . . . . . . . . . . . +90˚C 2. Clear space between single core cables: • flat formation: external diameter of the cable • trefoil formation: cables touch one another 3. Screen circuit: • open: screen circuits of the cables are connected together and earthed at one end only • closed: screen circuits are connected together at both ends and earthed at least at one end 4. Aerial installation • Ambient air temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +25˚C Frequency 50 Hz Closed screen circuit In the trefoil formation the single core cables touch one another, in the flat formation the clear space between the cables is equal to the external diameter of the cable. 5. Underground installation • Ground temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +15˚C • Depth: cables below 110 kV . . . . . . . . . . . . . . 0,7 m 110 kV cables. . . . . . . . . . . . . . . . . . . . 1,0 m • Thermal resistivity of the ground. . . . . . . . . . . . . . . . 1,0 Km/W The DC-resistance can be converted to match other temperatures, using the equation: If XLPE cables are laid underground, it is important to remember that a continuous conductor temperature of +90˚C may dry up the surrounding ground, causing an overload on the cable. For this reason, the continuous conductor temperature should not exceed +65˚C in XLPE insulated underground cables. Rt = R20 ( 1 + a20 ( t – 20 )) where Rt resistance at temperature t R20 resistance at +20˚C t temperature of the conductor [˚C] α20 temperature factor of resistivity [1/˚C] 0,00393 1/˚C with copper conductors 0,00403 1/˚C with aluminium conductors/sheaths 0,00400 1/˚C with lead alloy sheaths If conditions differ from the above-assumed premises, the maximum permissible loads must be multiplied by correction factors, which are given on next pages. Capacitance Capacitances are average values with the rated voltage at a temperature of +20˚C and at a frequency of 50 Hz. Especially with PVC-insulated cables, the capacitance will increase by 40 per cent if the temperature of the conductor rises from +20˚C to the maximum permissible continuous conductor temperature. 4 | Draka Keila Cables Product Catalogue Basic cable data Correction factors for underground installation The effect of several adjacent cables in the ground. The factor of three core cables and for groups of three single core cables. Thermal resistivity in the ground Clear space between Number of adjacent cables or groups of single core cables the cables or between the groups of single core cables mm 2 3 4 5 6 8 10 0 0,79 0,69 0,63 0,58 0,55 0,50 0,46 70 0,85 0,75 0,68 0,64 0,60 0,55 0,53 250 0,87 0,79 0,75 0,72 0,69 0,66 0,64 Thermal resistivity 0,7 in the ground Km/W 1,0 1,2 1,5 2,0 2,5 3,0 Correction factor 1,00 0,92 0,85 0,75 0,69 0,63 1,10 Thermal resistivity in different types of soil: – dry sand (moisture content 0%). . . . . . . . . . . . . . . . . . . . . 3.0 Km/W – dry gravel and clay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Km/W – semi-dry gravel, bog earth and sand (moisture 10%) . . . 1.2 Km/W – semi-dry clay and damp gravel. . . . . . . . . . . . . . . . . . . . . . . 1.0 Km/W – damp clay and sand (moisture content 25 %). . . . . . . . . . 0.7 Km/W Laying depth Cable Laying depth, m 0,50–0,70 0,71–0,90 0,91–1,10 1,11–1,30 1,31–1,50 0,61/1,0 kV 1,00 0,97 0,95 0,93 0,92 6/10–18/30 kV 1,00 0,99 0,98 0,96 0,95 Ground temperature Conductor temperature Ground temperature,˚C ˚C -5 0 5 10 15 20 25 30 35 40 45 90 1,13 1,10 1,06 1,03 1,00 0,96 0,93 0,89 0,86 0,82 0,77 80 1,14 1,11 1,07 1,04 1,00 0,96 0,92 0,88 0,83 0,78 0,73 70 1,17 1,13 1,09 1,04 1,00 0,95 0,90 0,85 0,80 0,73 0,67 65 1,18 1,14 1,10 1,05 1,00 0,95 0,89 0,84 0,77 0,71 0,63 Underground installation in PE or PVC tubes, with one three core cable or three single core cables. The cables are loaded at the same time. The tubes lie side by side. If the correction factors of this table are applied, the factors in the topmost table are not used Clear distance of the tubes Number of adjacent tubes mm 1 2 3 4 5 6 8 10 0 0,80 0,75 0,65 0,60 0,60 0,55 0,55 0,50 70 - 0,75 0,70 0,65 0,60 0,60 0,55 0,55 250 - 0,75 0,70 0,70 0,70 0,65 0,65 0,65 The tubes lie side by side. If the correction factors of this table applied, the factors in the topmost table are not used. The effect of cable cover slabs and troughs Type of covering Correction factor A concrete or brick slab more than 10 cm above the cable in well-compacted sandy ground 1,00 Bricks all around the cable, gaps sealed up tightly with sand 0,90 A concrete trough on the cable, compacted sand between the trough and the cable 0,90 A concrete or plastic trough on the cable, loose sand filler between the cable and the trough 0,80 Product Catalogue Draka Keila Cables | 5 Basic cable data Ambient air temperature Conductor temperature,˚C Ambient air temperature,˚C ˚C 10 15 20 25 30 35 40 45 50 55 90 1,12 1,08 1,04 1,00 0,95 0,90 0,85 0,80 0,74 0,68 80 1,14 1,09 1,05 1,00 0,95 0,89 0,48 0,77 0,69 0,61 70 1,18 1,12 1,06 1,00 0,95 0,86 0,79 0,71 0,62 0,52 65 1,20 1,14 1,07 1,00 0,95 0,85 0,77 0,68 0,57 0,45 CORRECTION FACTORS FOR AERIAL INSTALLATION OR FOR INSTALLATION TYPE B Cables in air = the same cooling conditions as when freely in air Installation type A INSTALLATION TYPE B: The cable is laid on the surface or so that between the cable and the surface of the covering material the thermal transmission factor is 11–50 W/˚C m2. The cable is laid on the surface or so that between the cable and the surface of the covering material the thermal trans¬mission factor is K>50 W/˚C m2. Installation type B includes one of the following: Installation type B includes one of the following: – surface installation – installation on a cable rack with short lead-through – disaccording to installation type B – – – – surface installation (also in a tube) with short lead-through installation on a cable rack with short lead-through sunk installation in stone structures (concrete, brick, etc.) installation in a riser shaft or in a cable duct The effect of grouping in aerial installation on the loading of Multicore alternating current cables and on single core direct current cables The data is valid, provided that the ambient temperature does not rise significantly in result of the increasing heat by dissipation in the cable. Arrangement of the cables Clear space = cable diameter (d); distance from the wall ≥ 20 mm Number of adjacent cables 1 On the floor or on the ceiling Correction factor 2 3 6 The cables touch one another and the wall 9 Drawing 1 20 mm 2 3 6 9 Drawing Correction factor d Unperforated trays Ladder supports, cleats, etc. 0,95 0,90 0,88 0,85 0,84 0,95 0,90 0,88 0,86 1,00 1,00 1,00 1,00 0,90 0,85 0,83 0,81 0,98 0,95 0,94 0,93 0,88 0,83 0,81 0,79 0,96 0,93 0,92 0,90 0,85 0,81 0,79 0,77 0,93 0,90 0,89 0,87 0,84 0,80 0,78 0,76 0,92 0,89 0,88 0,86 0,90 0,84 0,80 0,75 0,73 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,84 0,80 0,78 0,76 0,84 0,80 0,78 0,76 0,80 0,75 0,74 0,72 0,80 0,76 0,74 0,72 0,75 0,71 0,70 0,68 0,75 0,71 0,70 0,68 0,73 0,69 0,68 0,66 0,73 0,69 0,68 0,66 No, of racks 1 2 3 6 1 2 3 6 0,3 m d d 20 mm 0,3 m d 0,3 m 0,3 m d 20 mm Number of overlying cables 1 2 3 6 9 1 2 3 6 9 On racks or on the wall 1,00 0,93 0,90 0,87 0,86 0,95 0,78 0,73 0,68 0,66 d d 20 mm Installation with no need to reduce the load current Unrestricted number of overlying cables 2d d 20 mm 6 | Draka Keila Cables Unrestricted number of adjacent cables 0,3 m 2d 20 mm d Product Catalogue Basic cable data The effect of grouping in aerial installation on the loading of single core alternating current cables The data is valid, provided that the ambient temperature does not rise significantly in result of the increasing heat by dissipation in the cable. Arrangement of the cables Flat formation, clear space = cable diameter (d); distance from the wall >20 mm Cables touch one another and the wall Number of adjacent systems 1 1 On the floor or on the ceiling Correction factor 0,92 Unperforated trays 2 0,89 3 Drawing 20 mm d d 0,88 No, of racks d 3 Correction factor 0,95 20 mm 2 0,90 20 mm 20 mm 1 0,92 0,89 0,88 0,95 0,80 0,73 2 0,87 0,84 0,83 0,95 0,76 0,69 3 0,84 0,82 0,81 0,95 0,74 0,68 6 0,82 0,80 0,79 0,95 0,72 0,66 1 1,00 0,97 0,96 1,00 0,98 0,96 2 0,97 0,94 0,93 1,00 0,95 0,93 3 0,96 0,93 0,92 1,00 0,94 0,92 6 0,94 0,91 0,90 1,00 0,93 0,90 Number of overlying systems 1 2 3 1 2 3 On racks or on the wall 0,94 0,91 0,89 0,89 0,88 0,84 Ladder supports, cleats, etc. 20 mm d 0,3 m 20 mm d Installation with no need to the load current d 2d 2d 0,88 d 0,3 m Drawing 2d 0,3 m 20 mm 2d 2d 0,3 m 2d d With a longer distance, there are more reduce losses in the metal sheath and in the armouring, while cooling improves. Each case must be calculated separately. 2d 20 mm 4d 2d 0,3 m Short circuit current capacity Thermal stress Dynamic stress Taking into account the mechanical and electrical strength of the insulation, thermal stress by a short circuit is restricted by setting the maximum final conductor temperatures in a short circuit: Short circuit currents cause a mechanical load on the cable as well as on the accessories. – XLPE-insulated cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +250˚C – PVC-insulated 1 kV cables ≤ 300 mm2. . . . . . . . . . . . . . . . +160˚C > 300 mm2. . . . . . . . . . . . . . . . +140˚C The given values for maximum permissible short circuit currents in cable data have been calculated assuming the initial conductor temperature to be the maximum operating temperature in continuous use. The listed short circuit currents for duration of one second indicate the thermal capacity of the conductor. The maximum permissible thermal short circuit current for duration of 0.2 to 5 seconds can be computed by the equation: The dynamic short circuit stress is much greater near the high voltage network and near large power plants than farther out in the network. That is why the dynamic capacity of the accessories as well as the cable fittings must be checked. This is especially important with high power systems and with several parallel cables in aerial installation. Most important in a short circuit is the peak value of current, which is 2.5 times the short circuit current. To minimize dynamic stress, the installation must be made using the right accessories and the right technique. Ιt=Ι1s/√t where l1s = 1 s thermal short circuit current [kA] t = duration of the short circuit [s] Product Catalogue Draka Keila Cables | 7 Power cables ACSR Aluminium conductor steel reinforced Application Temperature range Bare conductor for overhead power transmission. Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . .80˚C – in a short circuit (duration up to 5 s) . . . . . . . . . 200˚C Standards SFS 5701 IEC 61089 EN 50182 8 | Draka Keila Cables Construction A conductor consisting aluminium and galvanized steel wires, built up in concentric layers. The centre wires are steel and outer layer aluminium wires. Product Catalogue Power cables ACSR Aluminium conductor steel reinforced Basic data Product name according to IEC EAN code Construction data Aluminium No of wires Diameter of wire Cross section Weight (5) Steel No of wires Diameter of wire Cross section Weight (5) Complete conductor No of wires Diameter of conductor Cross section Weight (5) Delivery data Standard delivery length Standard delivery drum Total weight (1) Mechanical data (2) Minimum tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Max. DC resistance of conductor (20˚C) (3) (5) Current ratings In air Short circuit currents (2) Max. permissible short circuit current for 1 sec. (4) ACSR 34/6 SPARROW 34-A1/S1A-6/1 01 202 02-2 ACSR 42/25 SAVO 42-A1/S1A-12/7 01 202 28-2 ACSR 54/9 RAVEN 54-A1/S1A-6/1 01 202 05-3 ACSR 85/14 PIGEON 85-A1/S1A-6/1 01 202 09-1 ACSR 89/52 DOTTEREL 89-A1/S1A-12/7 01 202 31-2 6 2,68 33,8 92,9 1 2,68 5,64 43,9 7 8,04 39,5 137 12 2,12 42,4 117 7 2,12 24,7 193 19 10,6 67,1 310 6 3,37 53,5 147 1 3,37 8,92 69,4 7 10,1 62,4 216 6 4,25 85,1 234,0 1 4,25 14,2 110,0 7 12,8 99,3 344,0 6 3,08 89,4 247,0 7 3,08 52,2 408,0 19 15,4 142 654,0 kg 2500 K11 390 2500 K12 860 2200 K11 560 2000 K12 770 2500 K16 1790 kN N/mm2 N/mm2 1/K 12,2 64000 78000 19,2 x 10–6 13,52 93000 102000 15,6 x 10–6 17,11 64000 78000 19,2 x 10–6 24,13 64000 78000 19,2 x 10–6 33,37 93000 102000 15,6 x 10–6 Ω/km 0,848 0,682 0,536 0,337 0,323 A 210 250 280 360 400 kA 3,7 5,4 5,8 9,2 11,4 64 100+ ACSR 152/25 OSTRICH 152-A1/S1A-26/7 01 202 15-2 ACSR 242/39 HAWK 242-A1/S1A-26/7 01 202 18-3 ACSR 305/39 DUCK 305-A1/S1A-54/7 01 202 21-3 ACSR 402/52 CONDOR 402-AL1/52-ST1A 01 054 07-2 ACSR 565/72 FINCH 565-A1/S1A-54/19 01 202 24-4 26 2,73 152 420 7 2,12 24,7 193 33 17,3 177 613 26 3,44 242 668 7 2,68 39,5 309 33 21,8 281 976 54 2,68 305 842 7 2,68 39,5 309 61 24,1 344 1151 54 3,08 402,3 1110,5 7 3,08 52,2 410 61 27,7 454,5 1520,5 54 3,65 565 1562 19 2,19 71,6 561 73 32,9 637 2123 kg 2500 K18 1760 2500 K20 2780 2200 K22 3290 2300 K22 3908 1400 K22 3380 kN N/mm2 N/mm2 1/K 54,8 61000 76000 19,2 x 10–6 84,9 61000 76000 19,2 x 10–6 96,8 50000 67000 19,3 x 10–6 123,75 51000 68000 19,3 x 10–6 174 46000 63000 19,3 x 10–6 Ω/km 0,190 0,120 0,0949 0,0719 0,0512 A 550 745 845 1000 1250 kA 16,5 26,1 32,5 43,7 60,1 64 100+ mm mm2 kg/km mm mm2 kg/km mm mm2 kg/km m Basic data Product name according to IEC EAN code Construction data Aluminium No of wires Diameter of wire Cross section Weight (5) Steel No of wires Diameter of wire Cross section Weight (5) Complete conductor No of wires Diameter of conductor Cross section Weight (5) Delivery data Standard delivery length Standard delivery drum Total weight (1) Mechanical data (2) Minimum tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Maximum DC resistance of conductor (20˚C) (3) (5) Current ratings In air Short circuit currents (2) Maximum permissible short circuit current for 1 sec. (4) mm mm2 kg/km mm mm2 kg/km mm mm2 kg/km m 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Calculated with steel core. 4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C. 5) Nominal value according to standard. Product Catalogue Draka Keila Cables | 9 Power cables HK Copper conductor Application Temperature range Grounding wire. Highest permissible conductor temperature short circuit (duration up to 5 s) . . . . . . . . . . . . . . 200˚C Standard Construction IEC 60228 Class 2 Concentric stranded soft copper conductor. Certificate/approval CE, RoHS Product name EAN code Customs code Constructional data Number of wires Diameter of wire Diameter of conductor Cross section Weight of conductor (1) Delivery data Standard delivery length Standard delivery drum Weight (1) cable+drum Electrical data (2) Max DC resistance of conductor 20˚C Short circuit currents (2) Max permissible short circuit current for 1 second (3) HK 16/7x1.68 coil/25 m 64 100+ 01 050 05-0 74.13.00.91 HK 16/7x1.68 coil/50 m 01 050 06-7 74.13.00.91 HK 16/7x1.68 coil/100 m 01 050 07-4 74.13.00.91 HK 25/7x2.12 coil/100 m 01 050 25-8 74.13.00.91 HK HK 16/7x1.68 drum 01 550 07-9 74.13.00.91 HK HK 25/7x2.12 drum 01 050 08-1 74.13.00.91 7 1,68 5,04 15,5 140 7 1,68 5,04 15,5 140 7 1,68 5,04 15,5 140 7 2,12 6,36 24,7 222 7 1,68 5,04 15,5 140 7 2,12 6,36 24,7 222 kg 25 coil 3,5 50 coil 7 100 coil 14 50 coil 11 500 K6 82 500 K6 123 Ω/km 1,15 1,15 1,15 0,727 1,15 0,727 kA 2,3 2,3 2,3 3,8 2,3 3,8 mm mm2 kg/km m Product name EAN code Customs code Constructional data Number of wires Diameter of wire Diameter of conductor Cross section Weight of conductor (1) Delivery data Standard delivery length Standard delivery drum Weight (1) cable+drum Electrical data (2) Max DC resistance of conductor 20˚C Short circuit currents (2) Max permissible short circuit current for 1 second (3) HK 35/7x2.50 drum 64 100+ 01 050 09-8 74.13.00.91 HK 50/19x1.77 drum 01 050 10-4 74.13.00.91 HK 70/19x2.12 drum 01 050 11-1 74.13.00.91 HK 95/19x2.50 drum 01 050 12-8 74.13.00.91 HK 120/37x2.01 drum 01 050 13-5 74.13.00.91 7 2,5 7,5 34,4 309 19 1,77 8,85 46,8 422 19 2,12 10,6 67,1 606 19 2,5 12,5 93,3 843 37 2,01 14,1 117 1062 kg 1000 K7 329 1000 K7 642 1000 K9 640 1000 K11 898 1000 K11 1152 Ω/km 0,524 0,387 0,268 0,193 0,153 kA 5,3 7,2 10,3 14,3 18 mm mm mm2 kg/km m 1) Approximate value 2) See the basic assumptions at general information of products. 3) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C. 10 | Draka Keila Cables Product Catalogue Power cables AS Aluminium conductor steel reinforced AS Application Temperature range Bare conductor. Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . 80 ˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . 200 ˚C Standard GOST 889-80 Construction Round, stranded aluminium steel reinforced conductor. Basic data EAN code AS 25 01 203 25 AS 35 01 203 35 AS 50 01 203 50 AS 70 01 203 70 AS 95 01 203 95 6 2,30 24,9 68,3 1 2,30 4,15 32,3 7 6,9 29,05 100,7 6 2,80 36,9 101,3 1 2,80 6,15 47,9 7 8,4 43,05 149,2 6 3,20 48,2 132,3 1 3,20 8,04 62,6 7 9,6 56,24 194,9 6 3,80 68,0 188,0 1 3,80 11,3 88,0 7 11,4 79,3 276,0 6 4,50 95,4 261,0 1 4,50 15,9 124,0 7 13,5 111,3 385,0 kg 4000 K9 430 4000 K11 645 3500 K11 740 2500 K11 745 2500 K14 1080 kN N/mm2 N/mm2 1/K 9,13 64000 78000 19,2 x 10–6 13,52 64000 78000 19,2 x 10–6 17,11 64000 78000 19,2 x 10–6 24,13 64000 78000 19,2 x 10–6 33,37 64000 78000 19,2 x 10–6 Ω/km 1,1521 0,7774 0,5951 0,4218 0,3007 A 142 175 210 265 330 kA 2,7 4,0 5,3 7,5 10,5 64 100+ Construction data Aluminium No of wires Steel Conductor Diameter over wire Cross section Weight (5) No of wires Diameter over wire Cross section Weight (5) No of wires Diameter over conductor Cross section Weight (5) Delivery data Standard delivery length Drum Total weight (1) Mechanical data (2) Minimum tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Maximum DC resistance of conductor (20 ˚C) (3) (5) Current ratings In air Short circuit currents (2) Max. permissible short circuit current for 1 second (4) mm mm2 kg/km mm mm2 kg/km mm mm2 kg/km m 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Calculated with steel. 4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C. 5) Standard based value. Product Catalogue Draka Keila Cables | 11 Power cables A Bare conductor A Application Bare conductor. Standard GOST 889-80 Temperature range Highest permissible conductor temperature:. – in continuous operation. . . . . . . . . . . . . . . . . . . . . . . 80 ˚C – in a short circuit (duration up to 5 s). . . . . . . . . . 200 ˚C Construction Round, stranded aluminium conductor. Basic data EAN code Construction data No of wires Diameter over wire Cross section Weight (5) Delivery data Standard delivery length Drum Total weight (1) Mechanical data (2) Minimum tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Maximum DC resistance of conductor (20˚C) (3) (5) Current ratings In air Short circuit currents (2) Maximum permissible short circuit current for 1 second (4) A 25 64 100+ 01 209 25 A 35 01 209 35 A 50 01 209 50 A 70 01 209 70 A 95 01 209 95 7 2,13 24,9 68 7 2,50 34,3 94 7 3,00 49,5 135 7 3,55 69,3 189 7 4,10 92,4 252 kg 4000 K9 300 4000 K11 425 3500 K11 520 2500 K11 520 2500 K12 720 kN N/mm2 N/mm2 1/K 4,50 41000 60000 23,0 x 10–6 5,91 41000 60000 23,0 x 10–6 8,19 41000 60000 23,0 x 10–6 11,28 41000 60000 23,0 x 10–6 14,78 41000 60000 23,0 x 10–6 Ω/km 1,1498 0,8347 0,5784 0,4131 0,3114 A 136 170 215 265 320 kA 2,5 3,4 5,0 7,0 9,3 mm mm2 kg/km m 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Calculated with steel. 4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C. 5) Standard based value. 12 | Draka Keila Cables Product Catalogue Power cables AXMK-PLUS and XMK-PLUS 1-core 1 kV power cable with XLPE insulated aluminium conductors and halogen-free outersheath Application Temperature range Designed for replacement of AXPK and AXPK-PE. The outer sheath is self-extinguishing and halogen-free. Cable is mechanically as strong as PE. For fixed installation indoors and outdoors, perfect for ploughing down. Suitable for cable ducts and house connections Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . .250˚C Lowest recommended handling temperature . . . . . –20˚C Construction Standards Conductor . . AXMK – round, stranded and compacted aluminium conductor XMK – round, stranded and compacted copper conductor Insulation . . . black XLPE compound Sheath . . . . . black halogen-free self-extinguishing PE compound; insulation and sheath are UV (1) resistible and they don't need extra protection against sunlight. SFS 4879, HD 603-5D S1, IEC 60502-1, IEC 60332-1 Cat. B Certificate/approval EEI, FI, CE Rated voltage U0/U = 0,6/1 kV, Um = 1,2 kV Marking Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking. Basic data AXMK 1x300 1 kV 64 100+ 06 261 02-4 EAN code Construction data AXMK 1x500 1 kV 06 210 27-5 AXMK 1x800 1 kV 06 261 05-5 XMK 1x300 1 kV 06 211 77-7 mm kg/km kg/km kg/km 29 795 1150 36 1312 1850 44 2160 2950 29 2620 3050 Standard delivery length Drum m cable + drum Total weight (2) Mechanical data (3) Minimum permissible bending radius during laying kg 1000 K18 1380 500 K18 1155 500 K20 1810 1000 K16 3240 m m kN kN 0,44 0,31 4,5 15,0 0,54 0,38 7,0 20,0 0,68 0,48 8,5 20,0 0,44 0,31 4,5 20,0 Ω/km 0,100 0,0605 0,0367 0,0601 A A A A 525 460 690 560 873 636 1000 830 1300 1050 665 580 845 735 kA 28,3 47,0 75,6 42,8 External cable diameter (2) Weight (2) aluminium copper cable Delivery data Minimum permissible bending radius at final installation (4) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (3) conductor 20˚C Maximum DC resistance of conductor Current ratings (3) Flat formation (in earth) conductor 70˚C Trefoil formation (in earth) conductor 70˚C Flat formation (in air) conductor 90˚C Trefoil formation (in air) conductor 90˚C Short circuit currents (3) Maximum permissible short circuit current for 1 second (5) 1) 2) 3) 4) 5) Product Catalogue UV – ultraviolet radiation Approximate value. See the basic assumptions at general information of products. Final installation with careful single bending. Initial temperature of conductor before short circuit 90˚C, final temperature of conductor after short circuit 250˚C. Draka Keila Cables | 13 Power cables AXPK-PLUS 1 kV power cable with XLPE insulated aluminium conductors and halogen-free outersheath Application Construction Designed for replacement of AXPK and AXPK-PE. The outer sheath is self-extinguishing and halogen-free. Cable is mechanically as strong as PE sheathed cable. For fixed installation indoors and outdoors, perfect for ploughing down. Suitable for cable ducts and house connections. FI, CE Conductor . . . . . . . 16 mm2 – solid round aluminium conductor; 25–300 mm2 – stranded, compacted and annealed sector shaped aluminium conductor Insulation . . . . . . . black XLPE compound Laying up . . . . . . . four insulated conductors stranded together Sheath . . . . . . . . . . black halogen-free self-extinguishing PE compound; insulation and sheath are UV (1) resistible and they don't need extra protection against sunlight. Rated voltage Identification of cores U0/U = 0,6/1 kV Um = 1,2 kV Phase conductors . . brown, black, grey PEN conductor . . . yellow-green Temperature range Marking Highest permissible conductor temperature: - in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C - in a short circuit (duration up to 5 s) . . . . . . . . . . 250˚C Lowest recommended temp. during laying . . . . . . . –20˚C Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking. Standards SFS 4879, HD 603-5D S1, IEC 60502-1, IEC 60332-1 Cat. B, HD 308 S2:2002 Certificate/approval 1) 14 | Draka Keila Cables UV – ultraviolet radiation Product Catalogue Power cables AXPK-PLUS 1 kV power cable with XLPE insulated aluminium conductors and halogen-free outersheath Basic cable data EAN code Construction data External cable diameter (1) Weight (1) aluminium cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Current ratings (2) In ground conductor 70˚C In air conductor 70˚C conductor 90˚C Short circuit currents (2) Maximum permissible short circuit current for 1 second (4) Basic cable data EAN code Construction data External cable diameter (1) Weight (1) aluminium cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Current ratings (2) In ground conductor 70˚C In air conductor 70˚C conductor 90˚C Short circuit currents (2) Maximum permissible short circuit current for 1 second (4) 4G16 64 100+ 06 210 07-7 4G25 06 210 08-4 4G35 06 210 09-1 4G50 06 210 10-7 4G70 06 210 11-4 4G95 06 210 12-1 mm kg/km kg/km 20 165 380 21 265 500 23 365 670 27 495 830 30 720 1170 34 995 1500 m kg 1000 K12 470 1000 K14 615 1000 K16 865 1000 K16 1025 1000 K18 1400 1000 K20 1840 m m kN kN 0,24 0,17 0,9 3,2 0,26 0,19 1,5 5,0 0,28 0,20 2,1 7,0 0,31 0,23 3,0 10,0 0,36 0,26 4,2 14,0 0,41 0,29 5,7 19,0 Ω/km Ω/km 1,91 2,3 1,20 1,5 0,868 1,0 0,641 0,77 0,443 0,53 0,320 0,39 A A A 78 64 75 100 83 105 125 105 130 150 125 165 185 155 205 220 190 245 kA 1,5 2,3 3,3 4,7 6,6 8,9 4G120 64 100+ 06 21013-8 4G150 06 210 14-5 4G185 06 210 15-2 4G240 6 210 16-9 4G300 mm kg/km kg/km 38 1260 1900 42 1550 2300 47 1950 2800 53 2550 3700 58 3190 4600 m kg 1000 K22 2310 500 K20 1490 500 K20 1740 500 K22 2260 500 K24 2750 m m kN kN 0,46 0,33 7,2 20,0 0,51 0,36 8,5 20,0 0,57 0,40 8,5 20,0 0,64 0,45 8,5 20,0 0,70 0,49 8,5 20,0 Ω/km Ω/km 0,253 0,31 0,206 0,25 0,164 0,20 0,125 0,16 0,100 0,13 A A A 255 220 280 290 250 320 330 285 365 375 330 430 430 380 480 kA 11,3 14,1 17,4 22,6 28,3 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 90˚C, final temperature of conductor after short circuit 250˚C. Product Catalogue Draka Keila Cables | 15 Power cables AXPK 1 kV power cable with XLPE insulated aluminium conductors Application Construction Fixed indoor, outdoor and underground installations. Conductor . . . . . . . 16 mm2 – solid round aluminium conductor; 25–300 mm2 – stranded, compacted and annealed sector shaped aluminium conductor Insulation . . . . . . . black XLPE compound Laying up . . . . . . . four insulated conductors stranded together Sheath . . . . . . . . . . black PVC; plastics are UV (1) resistible and they don't need extra protection against sunlight. Standards SFS 4879, HD 603-5D S1, IEC 60502-1, IEC 60332-1 Cat. B, HD 308 S2:2002 Certificate/approval EEI, FI, CE Rated voltage U0/U = 0,6/1 kV Um = 1,2 kV Temperature range Highest permissible conductor temperature: - in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C - in a short circuit (duration up to 5 s) . . . . . . . . . . 250˚C Lowest recommended temp. during laying . . . . . . . –15˚C 1) 16 | Draka Keila Cables Identification of cores Phase conductors . . brown, black, grey PEN conductor . . . yellow-green Marking Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking. UV – ultraviolet radiation Product Catalogue Power cables AXPK 1 kV power cable with XLPE insulated aluminium conductors Basic cable data EAN code Construction data External cable diameter (1) Weight (1) aluminium cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Current ratings (2) In ground conductor 70˚C In air conductor 70˚C conductor 90˚C Short circuit currents (2) Maximum permissible short circuit current for 1 second (4) Basic cable data EAN code Construction data External cable diameter (1) Weight (1) aluminium cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Current ratings (2) In ground conductor 70˚C In air conductor 70˚C conductor 90˚C Short circuit currents (2) Maximum permissible short circuit current for 1 second (4) 4G16 64 100+ 06 210 07-7 4G25 06 210 08-4 4G35 06 210 09-1 4G50 06 210 10-7 4G70 06 210 11-4 4G95 06 210 12-1 mm kg/km kg/km 20 165 380 21 265 500 23 365 670 27 495 830 30 720 1170 34 995 1500 m kg 1000 K12 470 1000 K14 615 1000 K16 865 1000 K16 1025 1000 K18 1400 1000 K20 1840 m m kN kN 0,24 0,17 0,9 3,2 0,26 0,19 1,5 5,0 0,28 0,20 2,1 7,0 0,31 0,23 3,0 10,0 0,36 0,26 4,2 14,0 0,41 0,29 5,7 19,0 Ω/km Ω/km 1,91 2,3 1,20 1,5 0,868 1,0 0,641 0,77 0,443 0,53 0,320 0,39 A A A 78 64 75 100 83 105 125 105 130 150 125 165 185 155 205 220 190 245 kA 1,5 2,3 3,3 4,7 6,6 8,9 4G120 64 100+ 06 21013-8 4G150 06 210 14-5 4G185 06 210 15-2 4G240 6 210 16-9 4G300 mm kg/km kg/km 38 1260 1900 42 1550 2300 47 1950 2800 53 2550 3700 58 3190 4600 m kg 1000 K22 2310 500 K20 1490 500 K20 1740 500 K22 2260 500 K24 2750 m m kN kN 0,46 0,33 7,2 20,0 0,51 0,36 8,5 20,0 0,57 0,40 8,5 20,0 0,64 0,45 8,5 20,0 0,70 0,49 8,5 20,0 Ω/km Ω/km 0,253 0,31 0,206 0,25 0,164 0,20 0,125 0,16 0,100 0,13 A A A 255 220 280 290 250 320 330 285 365 375 330 430 430 380 480 kA 11,3 14,1 17,4 22,6 28,3 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 90˚C, final temperature of conductor after short circuit 250˚C. Product Catalogue Draka Keila Cables | 17 Power cables EMC-Line 1 kV (IFSI) Halogen-free EMC compatible power cable with aluminium conductor Application Approvals Power cable with rated voltage up to 1 kV. Halogen-free cable for indoor and outdoor use, to secure areas from heavy smoke and corrosive gases in case of fire. Improved EMC screen according to EMC directive. National regulations for electrical installations must be followed. NEMKO CE-marked, acc. to LVD(1) Max conductor temperature. . . . . . . . . . . . . . . . . . . . 9O˚C Rated voltage U0/U . . . . . . . . . . . . . . . . . . . . . . . . . 0,6/1 kV CENELEC designation . . . . . . . . . . . . . . . . N1ZCZ1-AR (AS) Standards applied HD 604-5D Construction IEC 60502-1 Insulation IEC 60332-3C Flame Retardancy IEC 60754-1 and 2 Halogen-free IEC 61034 Low Smoke No. of cores and conductor area mm2 3x25/10 3 x 50/16 3 x 95/35 3 x 150/50 3 x 240/70 4 x 25/10 4 x 50/16 4 x 95/35 4 x 150/50 4 x 240/70 Construction Conductor . . . . . . . . . . . stranded aluminium Insulation . . . . . . . . . . . . cross-linked halogen-free polymer Bedding/tape . . . . . . . . halogen-free Concentric conductor . . (PE/PEN conductor) copperfoil with overlap and concentric screen of copper wires Outer sheath . . . . . . . . . halogen-free polymer Colour . . . . . . . . . . . . . . . black Mode of packing . . . . . . drum Marking Printed on outer sheath, designation and dimension. Meter marking and year of production. Conductor type (2) Art. No. AFR AFV AFV AFV AFV AFR AFV AFV AFV AFV 478130 478170 478210 478553 478563 478135 478175 478215 478556 478566 Outer diameter approx. mm 23 26 34 40 49 25 29 36 45 55 Approx. weight kg/km 550 850 1590 2290 3520 660 1050 1920 2820 4400 Normal delivery length m 500 500 500 500 400 500 500 500 500 400 1) LVD – Low Voltage Directive 2) ER – Solid round FR – Stranded round FV – Stranded sector shaped 18 | Draka Keila Cables Product Catalogue Power cables EMC-Line 1 kV (IFSI) Halogen-free EMC compatible power cable with copper conductor Application Approvals Power cable with rated voltage up to 1 kV. Halogen-free cable for indoor and outdoor use, to secure areas from heavy smoke and corrosive gases in case of fire. Improved EMC screen according to EMC directive. National regulations for electrical installations must be followed. NEMKO, CE-marking, acc. to LVD (1) Max conductor temp. . . . . . . . . . . . . . . . . . . . . . . . . . . 9O˚C Rated voltage U0/U . . . . . . . . . . . . . . . . . . . . . . . . . 0,6/1 kV CENELEC designation N1ZA5Z1-U, N1ZCZ1-U (R-S) Standards applied HD 604-5D Construction IEC 60502-1 Insulation IEC 60332-3C Flame Retardancy IEC 60754-1 and 2 Halogen-free IEC 61034 Low Smoke Construction Conductor . . . . . . . . . . . solid or stranded copper Insulation . . . . . . . . . . . . cross-linked Halogen-free polymer Bedding/tape . . . . . . . . halogen-free Concentric conductor . . (PE/PEN conductor) 1,5–2,5 mm2 have aluminium tape with drain wire; >4 mm2 have copperfoil with overlap and concentric screen of copper wires Outer sheath . . . . . . . . . halogen-free polymer Colour . . . . . . . . . . . . . . . black Mode of packing . . . . . . drum Marking Printed on outer sheath, designation and dimension. Meter marking and year of production. No. of cores and conductor area mm2 2 x 1,5/1,5 2 x 2,5/2,5 2 x 4/4 2 x 6/6 2 x 10/10 2 x 16/16 3 x 1,5/1,5 3 x 2,5/2,5 3 x 4/4 3 x 6/6 3 x 10/10 3 x 16/16 3 x 25/16 3 x 35/16 3 x 50/25 3 x 70/35 3 x 95/50 3 x 120/70 Conductor Art. No. type (2) ER ER ER ER FR FR ER ER ER ER FR FR FR FV FV FV FV FV 422005 422025 422045 422065 422085 422105 422010 422030 422050 422070 422090 422110 422130 422150 422170 422190 422210 422230 Outer diameter approx. mm 11 12 13 14 18 20 11 12 13 14 18 21 24 24 26 30 33 38 Approx. weight kg/km 170 210 210 270 440 640 180 230 250 330 550 820 1110 1390 1800 2520 3450 4290 No. of cores and conductor area mm2 3 x 150/70 3 x 185/95 3 x 240/120 4 x 1,5/1,5 4 x 2,5/2,5 4 x 4/4 4 x 6/6 4 x 10/10 4 x 25/16 4 x 35/16 4 x 50/25 4 x 70/35 4 x 95/50 4 x 120/70 4 x 150/70 4 x 185/95 4 x 240/120 Conductor Art. No. type (2) FV FV FV ER ER ER ER FR FR FV FV FV FV FV FV FV FV 422250 422290 422015 422035 422055 422075 422095 422135 422175 422195 422215 422235 422255 422275 422295 Outer diameter approx. mm 40 48 53 12 13 14 16 20 26 28 28 35 39 42 46 53 59 Approx. weight kg/km 5200 7200 8500 210 280 300 400 660 1370 1850 2270 3200 4380 5430 6590 8750 10900 1) LVD – Low Voltage Directive 2) ER – Solid round FR – Stranded round FV – Stranded sector shaped Product Catalogue Draka Keila Cables | 19 Power cables AMCMK 3 1/2-core 1 kV power cable with PVC insulated aluminium conductors Application Fire resistance class Fixed indoor, outdoor and underground installations. 25 – 300 mm2 . . . . IEC 60332-3 category B 16 mm2 . . . . . . . . . . IEC 60332-1 Standards SFS 4880 HD 603-3F S1 IEC 60502-1 IEC 60332-3 category B Certificate/approval FI, CE Rated voltage U0/U = 0,6/1 kV Um = 1,2 kV Temperature range Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . 160˚C Lowest recommended temperature during laying . . –15˚C 20 | Draka Keila Cables Construction Conductor . . . . . . . 16 mm2 – solid round annealed aluminium conductor; 25–300 mm2 – stranded, compacted and annealed sector shaped aluminium conductor Insulation . . . . . . . . PVC Laying up . . . . . . . . three insulated phase conductors stranded together PE conductor . . . . contcentric copper wire layer and copper wire or copper tape binding Sheath . . . . . . . . . . black PVC compound Identification of cores Phase conductors brown, black, grey (HD 308 S2:2002) Marking Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking. Product Catalogue Power cables AMCMK 3 1/2-core 1 kV power cable with PVC insulated aluminium conductors Basic cable data Construction data External cable diameter (1) Weight (1) Delivery data Standard delivery length Drum Total weight (1) Mechanical data (2) aluminium copper cable cable + drum Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PEN conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short circuit phase conductor (4) current for 1 second PE conductor (5) AMCMK 3x16Al/10Cu AN 1 kV AMCMK 3x25Al/16Cu AN 1 kV AMCMK 3x35Al/16Cu AN 1 kV AMCMK 3x50Al/16Cu AN 1 kV AMCMK 3x70Al/21Cu AN 1 kV AMCMK 3x95Al/29Cu AN 1 kV mm kg/km kg/km kg/km 22 125 95 560 23 200 145 620 24 275 145 730 28 370 145 975 31 540 190 1300 35 750 260 1750 m kg 1000 15G 710 500 K11 365 500 K12 485 500 K12 580 500 K14 765 500 K14 990 m m kN kN 0,25 0,18 0,7 2,4 0,28 0,20 1,1 3,7 0,30 0,21 1,6 5,2 0,34 0,24 2,2 7,5 0,38 0,27 3,1 10,5 0,42 0,30 4,3 14,2 Ω/km Ω/km Ω/km mH/km µF/km 1,91 2,3 1,91 0,26 0,40 1,20 1,4 1,91 0,26 0,45 0,868 1,0 1,91 0,26 0,55 0,641 0,77 1,20 0,25 0,60 0,443 0,53 0,868 0,24 0,65 0,320 0,39 0,641 0,24 0,75 A A 64 78 83 100 105 125 125 150 155 185 190 220 kA kA 1,2 1,7 1,9 1,7 2,6 1,7 3,8 2,6 5,3 3,7 7,2 4,6 Basic cable data Construction data External cable diameter (1) Weight (1) aluminium copper cable AMCMK 3x120Al/41Cu AN 1 kV AMCMK 3x150Al/41Cu AN 1 kV AMCMK 3x185Al/57Cu AN 1 kV AMCMK 3x240Al/72Cu AN 1 kV AMCMK 3x300Al/88Cu AN 1 kV mm kg/km kg/km kg/km 39 945 370 2150 42 1160 370 2550 48 1460 525 3250 53 1910 660 4100 58 2390 790 5000 m kg 500 K16 1270 500 K18 1500 500 K20 1950 500 K22 2450 500 K24 2950 m m kN kN 0,47 0,33 5,4 18,0 0,51 0,36 6,7 20,0 0,58 0,41 8,3 20,0 0,64 0,45 8,5 20,0 0,70 0,49 8,5 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,253 0,31 0,443 0,23 0,80 0,206 0,25 0,443 0,23 0,80 0,164 0,20 0,320 0,23 0,85 0,125 0,15 0,253 0,23 0,85 0,100 0,13 0,206 0,23 0,90 A A 220 255 250 290 285 330 330 375 380 430 kA kA 9,1 6,7 11,4 6,7 14,0 8,8 18,2 11,4 22,8 13,9 Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PEN conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short circuit phase conductor (4) current for 1 second PE conductor (5) 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 21 Power cables AMCMK 4 1/2-core 1 kV power cable with PVC insulated aluminium conductors Application Construction Fixed indoor, outdoor and underground installations. Conductor . . . . . . . stranded, compacted and annealed sector shaped aluminium conductor Insulation . . . . . . . . PVC Laying up . . . . . . . . three insulated phase conductors and neutral conductor stranded together PE conductor . . . . concentric copper wire layer and copper wire or copper tape binding Sheath . . . . . . . . . . black PVC compound Standards SFS 4880, HD 603-3F S1, IEC 60502-1 Certificate/approval EEI, FI, CE Rated voltage U0/U = 0,6/1 kV Um = 1,2 kV Fire resistance class Phase conductors brown, black, grey and neutral conductor blue (HD 308 S2:2002). IEC 60332-3 cat B Marking Temperature range Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking. Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying . . –15˚C 22 | Draka Keila Cables Identification of cores Product Catalogue Power cables AMCMK 4 1/2-core 1 kV power cable with PVC insulated aluminium conductor Basic cable data Construction data External cable diameter (1) Weight (1) aluminium copper cable Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short circuit phase conductor (4) current for 1 second PE conductor (5) AMCMK 4x35Al/16Cu AN 1 kV AMCMK 4x50Al/16Cu AN 1 kV AMCMK 4x70Al/21Cu AN 1 kV AMCMK 4x95Al/29Cu AN 1 kV AMCMK 4x120Al/41Cu AN 1 kV mm kg/km kg/km kg/km 28 365 145 955 32 495 145 1250 35 720 195 1600 40 1000 270 2200 44 1260 370 2650 m kg 500 K12 570 500 K14 740 500 K16 995 500 K18 1330 500 K20 1670 m m kN kN 0,34 0,24 2,1 7,0 0,39 0,28 3,0 10,0 0,42 0,3 4,2 14,0 0,48 0,34 5,7 19,0 0,53 0,37 7,2 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,868 1,00 1,15 0,27 0,45 0,641 0,77 1,15 0,27 0,50 0,443 0,53 0,868 0,26 0,55 0,32 0,39 0,641 0,26 0,65 0,253 0,31 0,443 0,26 0,70 A A 105 125 125 150 155 185 190 220 220 255 kA kA 2,6 2,6 3,8 2,6 5,3 3,7 7,2 4,6 9,1 6,7 AMCMK 4x150Al/41Cu AN 1 kV AMCMK 4x185Al/57Cu AN 1 kV AMCMK 4x240Al/72Cu AN 1 kV AMCMK 4x300Al/88Cu AN 1 kV mm kg/km kg/km kg/km 48 1550 370 3150 53 1950 510 4000 60 2550 660 5100 66 3190 795 6300 m kg 500 K20 3150 500 K22 2400 400 K22 3000 500 K24 3600 m m kN kN 0,58 0,41 8,5 20,0 0,64 0,45 8,5 20,0 0,72 0,51 8,5 20,0 0,80 0,56 8,5 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,206 0,25 0,443 0,26 0,70 0,164 0,20 0,320 0,26 0,75 0,125 0,15 0,253 0,26 0,80 0,1 0,13 0,206 0,26 0,80 A A 250 290 285 330 330 375 380 430 kA kA 11,4 6,7 14,0 8,8 18,2 11,4 22,8 13,9 Basic cable data Construction data External cable diameter (1) Weight (1) aluminium copper cable Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short circuit phase conductor (4) current for 1 second PE conductor (5) 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 23 Power cables MCMK 3-core 1 kV power cable with PVC insulated copper conductors Application Construction For fixed installation indoors, outdoors and underground as well as in building structures, e.g. directly in concrete. Not for installations subject to severe electrical interference (see MCCMK). CE, EEI, FI, S Conductor . . . . . . . annealed copper; 1,5–6 mm2 – solid; 10 mm2 – stranded, round (RM) Insulation . . . . . . . . lead-free PVC Laying up . . . . . . . . phase conductor and neutral conductor stranded together Filling . . . . . . . . . . . filling compound PE conductor . . . . concentric layer of copper wires and an open helix of parallel copper wires Sheath . . . . . . . . . . black, lead-free PVC compound Rated voltage Identification of cores U0/U = 0,6/1 kV, Um = 1,2 kV Colour marking . . . blue, brown According to HD 308 S2:2002. Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1 Certificate/approval Temperature range Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying. . . –15˚C Basic cable data EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force, pulling by phase conductors Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Maximum permissible short phase and neutral conductor (4) circuit current for 1 second PE conductor (5) Marking Manufacturer, product name, FI-mark, year and week of manufacture, meter marking. MCMK 2x1,5/1,5 1 kV 64 100+ 06 021 22-2 MCMK MCMK 2x2,5/2,5 1 kV 2x6/6 1 kV 06 021 25-3 06 021 23-9 MCMK 2x10/10 RM 1 kV 06 021 26-0 mm kg/km kg/km 11,5 41 165 12,5 66 200 16,5 159 370 19 268 550 m kg 1000 K8 210 1000 K8 225 500 K8 220 500 K9 320 m m kN 0,14 0,09 0,15 0,15 0,10 0,25 0,19 0,13 0,60 0,23 0,16 1,00 Ω/km Ω/km Ω/km mH/km µF/km 12,1 14,5 12,1 0,34 0,25 7,41 8,87 7,41 0,32 0,30 3,08 3,69 3,08 0,30 0,35 1,83 2,19 1,83 0,28 0,40 A A 26 14 35 20 57 33 77 62 kA kA 0,18 0,24 0,30 0,42 0,70 1,0 1,1 1,7 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C. 24 | Draka Keila Cables Product Catalogue Power cables MCMK 4-core 1 kV power cable with PVC insulated copper conductors Application Construction For fixed installation indoors, outdoors and underground as well as in building structures, e.g. directly in concrete. Not for installations subject to severe electrical interference (see MCCMK). CE, FI, S, EEI Conductor . . . . . .annealed copper; 1,5–6 mm2 – solid round; 10 and 16 mm2 – stranded, round (RM) Insulation . . . . . . .lead-free PVC Laying up . . . . . . .three phase conductors stranded together Filling . . . . . . . . . .filling compound PE conductor . . . .concentric layer of copper wires and an open helix of parallel copper wires Sheath . . . . . . . . .black, lead-free PVC compound Rated voltage Identification of cores U0/U = 0,6/1 kV, Um = 1,2 kV Colour marking . .brown, black, grey According to HD 308 S2:2002. Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1 Certificate/approval Temperature range Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying. . . –15˚C Basic cable data EAN code Construction data External cable diameter (1) Weight (1) Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Min permissible bending radius during laying Min permissible bending radius at final installation (3) Max permissible pulling force, pulling by phase conductors Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C PE conductor 20˚C Maximum DC resistance of Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Max permissible short circuit current for 1 second phase conductor (4) PE conductor (5) Manufacturer, product name, FI-mark, year and week of manufacture, meter marking MCMK MCMK MCMK 3x1,5/1,5 1 kV 3x2,5/2,5 1 kV 3x6/6 1 kV 06 021 52-9 06 021 53-6 06 021 55-0 MCMK MCMK 3x10/10 RM 1 kV 3x16/16 RM 1 kV 06 021 56-7 06 021 57-4 mm kg/km kg/km 12 54 190 13 88 240 17 212 450 20 357 680 23 570 970 m kg 1000 K8 220 1000 K9 290 500 K8 260 500 K9 390 500 K11 570 m m kN 0,15 0,10 0,22 0,16 0,11 0,37 0,21 0,15 0,90 0,24 0,16 1,5 0,28 0,19 2,4 Ω/km Ω/km Ω/km mH/km µF/km 12,1 14,5 12,1 0,34 0,25 7,41 8,87 7,41 0,32 0,30 3,08 3,69 3,08 0,30 0,35 1,83 2,19 1,83 0,28 0,40 1,15 1,38 1,15 0,26 0,40 A A 26 14 35 20 57 33 77 62 100 82 kA kA 0,18 0,24 0,30 0,42 0,7 1,0 1,1 1,7 1,8 2,7 64 100+ copper cable Marking 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 25 Power cables MCMK 5-core 1 kV power cable with PVC insulated copper conductors Application Construction For fixed installation indoors, outdoors and underground as well as in building structures, e.g. directly in concrete. Not for installations subject to severe electrical interference (see MCCMK). EEI, CE, FI, S Conductor . . . . . . . annealed copper 1,5–6 mm2 – solid 10 and 16 mm2 – stranded, round (RM) Insulation . . . . . . . . lead-free PVC Laying up . . . . . . . . three phase conductors and neutral conductor stranded together Filling . . . . . . . . . . . filling compound PE conductor . . . . concentric layer of copper wires and an open helix of parallel copper wires Sheath . . . . . . . . . . black, lead-free PVC compound Rated voltage Identification of cores U0/U = 0,6/1 kV, Um = 1,2 kV Colour marking . . . blue, brown, black, grey According to HD 308 S2:2002. Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1 Certificate/approval Temperature range Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying . . .-15˚C 26 | Draka Keila Cables Marking Manufacturer, product name, FI-mark, year and week of manufacture, meter marking Product Catalogue Power cables MCMK 5-core 1 kV power cable with PVC insulated copper conductors Basic cable data MCMK 4x1,5/1,5 1 kV EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force, pulling by phase conductors Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Max permissible short circuit current for 1 second phase and neutral conductor (4) PE conductor (5) MCMK 4x1,5/1,5 1 kV MCMK MCMK 4x2,5/2,5 1 kV 4x2,5/2,5 1 kV drum 64 100+ 06 021 72-7 reel 06 021 92-5 drum 06 021 43-7 reel 06 021 93-2 mm kg/km kg/km 13 68 210 13 68 210 14 110 270 14 110 270 m kg 1000 K8 235 100 reel 21 1000 K9 320 100 reel 27 m m kN 0,16 0,11 0,3 0,16 0,11 0,3 0,17 0,12 0,5 0,17 0,12 0,5 Ω/km Ω/km Ω/km mH/km µF/km 12,1 14,5 12,1 0,34 0,25 12,1 14,5 12,1 0,34 0,25 7,41 8,87 7,41 0,32 0,30 7,41 8,87 7,41 0,32 0,30 A A 26 14 26 14 35 20 35 20 kA kA 0,18 0,24 0,18 0,24 0,30 0,42 0,30 0,42 Basic cable data MCMK 4x6/6 1 kV EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force, pulling by phase conductors Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Max permissible short circuit current for 1 second phase and neutral conductor (4) PE conductor (5) MCMK 4x10/10 RM 1 kV MCMK 4x16/16 RM 1 kV drum 64 100+ 06 021 45-1 drum 06 021 46-8 drum 06 021 47-5 mm kg/km kg/km 18,5 265 520 22 447 790 25 712 1150 m kg 500 K8 285 500 K11 480 500 K11 630 m m kN 0,22 0,15 1,2 0,25 0,17 2,0 0,29 0,20 3,2 Ω/km Ω/km Ω/km mH/km µF/km 3,08 3,69 3,08 0,30 0,35 1,83 2,19 1,83 0,28 0,40 1,15 1,38 1,15 0,26 0,40 A A 57 33 77 62 100 82 kA kA 0,70 1,0 1,1 1,7 1,8 2,7 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 27 Power cables MCCMK 4-core 1 kV EMC power cable with PVC-insulated copper conductor Application Construction Fixed indoor, outdoor and underground installation where EMC properties are required. Conductor . . . . . . . annealed copper; 2,5 and 6 mm2 – solid round; 10 and 16 mm2 – stranded round (RM) Insulation . . . . . . . . lead-free PVC Laying up . . . . . . . . three phase conductors stranded together Filling . . . . . . . . . . . filling compound PE conductor . . . . copper foil and concentric layer of copper wires Sheath . . . . . . . . . . black, lead-free PVC compound Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60322-1 Certificate/approval EEI, FI, CE Rated voltage U0/U = 0,6/1 kV Um = 1,2 kV Identification of cores Colour marking . . . brown – black – grey According to HD 308 S2:2002. Temperature range Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . 160˚C Lowest recommended temperature during laying . . –15˚C Basic cable data EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C PE conductor 20˚C Maximum DC resistance of Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Maximum permissible short phase conductor (4) circuit current for 1 second PE conductor (5) Marking Manufacturer, product name, FI-mark, year and week of manufacture, meter marking MCCMK 3x2,5/2,5 1 kV 64 100+ 06 020 53-9 MCCMK MCCMK MCCMK 3x6/6 1 kV 3x10/10 RM 1 kV 3x16/16 RM 1 kV 06 020 55-3 06 020 56-0 06 020 57-7 mm kg/km kg/km 14 88 260 18 212 470 21 357 700 24 570 1050 m kg 1000 K9 320 1000 K11 560 1000 K12 820 1000 15G 1250 m m kN 0,16 0,11 0,37 0,22 0,15 0,90 0,25 0,17 1,5 0,30 0,20 2,4 Ω/km Ω/km Ω/km mH/km µF/km 7,41 8,87 7,41 0,32 0,30 3,08 3,69 3,08 0,30 0,35 1,83 2,19 1,83 0,26 0,40 1,15 1,38 1,15 0,26 0,40 A A 35 20 57 33 77 62 100 82 kA kA 0,18 0,24 0,30 0,42 0,7 1,0 1,1 1,7 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C. 28 | Draka Keila Cables Product Catalogue Power cables MCCMK 5-core 1 kV EMC power cable with PVC-insulated copper conductor Application Construction Fixed indoor, outdoor and underground installation where EMC properties are required. Rated voltage Conductor . . . . . . . annealed copper 2,5 and 6 mm2 – solid round 10 and 16 mm2 – stranded round (RM) Insulation . . . . . . . . lead-free PVC Laying up . . . . . . . . three phase conductors and neutral conductor stranded together Filling . . . . . . . . . . . filling compound PE conductor . . . . copper foil and concentric layer of copper wires Sheath . . . . . . . . . . black, lead-free PVC compound U0/U = 0,6/1 kV, Um = 1,2 kV Identification of cores Temperature range Colour marking . . . blue, brown, black, grey According to HD 308 S2:2002. Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1 Certificate/approval EEI, FI, CE Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying . . .-15˚C Basic cable data Manufacturer, product name, FI-mark, year and week of manufacture, meter marking. MCCMK MCCMK MCCMK MCCMK 4x2,5/2,5 1 kV 4x6/6 1 kV 4x10/10 RM 1 kV 4x16/16 RM 1 kV 64 100+ 06 020 73-7 06 020 75-1 06 020 76-8 06 020 77-5 EAN code Construction data External cable diameter (1) Weight (1) Marking copper cable Delivery data Standard delivery length Drum cable + drum Total weight (1) Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Maximum permissible short phase conductor and circuit current for 1 second neutral conductor (4) PE conductor (5) mm kg/km kg/km 14,5 110 290 19 265 540 22 447 830 25 712 1200 m kg 1000 K9 350 1000 K11 640 1000 13G 970 1000 15G 1400 m m kN 0,18 0,12 0,50 0,23 0,16 1,2 0,27 0,18 2,0 0,30 0,20 3,2 Ω/km Ω/km Ω/km mH/km µF/km 7,41 8,87 7,41 0,32 0,30 3,08 3,69 3,08 0,30 0,35 1,83 2,19 1,83 0,28 0,40 1,15 1,38 1,15 0,26 0,40 A A 35 20 57 33 77 62 100 82 kA 0,30 0,70 1,1 1,8 kA 0,42 1,0 1,7 2,7 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 29 Power cables MCMK 3 1/2-core 1 kV power cable with PVC insulated copper conductors Application Construction Fixed indoor, outdoor and underground installations. Conductor . . . . . . . stranded, compacted and annealed sector shaped copper conductor Insulation . . . . . . . . PVC Laying up . . . . . . . . three insulated phase conductors stranded together PE conductor . . . . concentric copper wire layer and copper wire or copper tape binding Sheath . . . . . . . . . . black PVC compound Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-3 Certificate/approval EEI, FI, CE Rated voltage U0/U = 0,6/1 kV, Um = 1,2 kV Fire resistance class Phase conductors brown, black, grey. According to HD 308 S2:2002. IEC 60332-3 cat B Marking Temperature range Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying. . . –15˚C 30 | Draka Keila Cables Identification of cores Product Catalogue Power cables MCMK 3 1/2-core 1 kV power cable with PVC insulated copper conductors Basic cable data EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C PE conductor 20˚C Maximum DC resistance of Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short phase conductor (4) circuit current for 1 second PE conductor (5) Basic cable data EAN code Construction data External cable diameter (1) Weight (1) 3x95/50 AN 1 kV 06 021 62-8 mm kg/km kg/km 23 800 1150 25 1050 1450 28 1460 2000 31 2080 2700 37 2880 3700 m kg 500 K12 630 500 K12 815 500 K12 1090 500 K14 1470 500 K16 2050 m m kN kN 0,28 0,20 1,1 7,5 0,30 0,21 1,5 10,5 0,34 0,24 2,2 15,0 0,38 0,26 3,1 20,0 0,45 0,31 4,2 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,727 0,87 1,15 0,26 0,45 0,524 0,63 1,15 0,26 0,55 0,387 0,47 0,727 0,25 0,60 0,268 0,32 0,524 0,24 0,65 0,193 0,23 0,387 0,24 0,75 A A 107 130 135 160 160 190 200 240 245 285 kA kA 2,8 2,7 4,0 2,7 5,7 4,4 8,0 5,7 10,9 7,2 3x120/70 AN 1 kV 3x150/70 AN 1 kV 3x185/95 AN 1 kV 3x240/120 AN 1 kV 3x300/150 AN 1 kV 64 100+ 06 021 63-5 06 021 64-2 06 021 65-9 06 021 66-6 06 021 75-8 mm kg/km kg/km 39 3710 4650 43 4430 5550 48 5630 7000 59 7350 9100 59 9240 11500 m kg 500 K18 2560 500 K18 3000 500 K20 3850 500 K22 4950 500 K24 6200 m m kN kN 0,47 0,33 5,4 20,0 0,52 0,37 6,7 20,0 0,58 0,41 8,3 20,0 0,64 0,45 8,5 20,0 0,71 0,50 8,5 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,153 0,19 0,268 0,23 0,80 0,124 0,15 0,268 0,23 0,80 0,0991 0,12 0,193 0,23 0,85 0,0754 0,097 0,153 0,23 0,85 0,0601 0,081 0,124 0,23 0,90 conductor 70˚C conductor 70˚C A A 280 325 320 370 365 420 425 480 490 550 phase conductor (4) PE conductor (5) kA kA 13,7 10,4 17,2 10,4 21,2 13,4 27,5 16,6 34,4 19,2 copper cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C PE conductor 20˚C Maximum DC resistance of Inductance (1) Operating capacitance (1) Current ratings (2) In air In ground Short circuit currents (2) Maximum permissible short circuit current for 1 second 3x25/16 AN 1 kV 3x35/16 AN 1 kV 3x50/25 AN 1 kV 3x70/35 AN 1 kV 64 100+ 06 021 58-1 06 021 59-8 06 021 60-4 06 021 61-1 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 31 Power cables MCMK 4 1/2-core 1 kV power cable with PVC insulated copper conductors Application Construction Fixed indoor, outdoor and underground installations. Certificate/approval Conductor . . . . . . . stranded, compacted and annealed sector shaped copper conductor Insulation . . . . . . . . PVC Laying up . . . . . . . . three insulated phase conductors and neutral conductor stranded together PE conductor . . . . concentric copper wire layer and copper wire or copper tape binding Sheath . . . . . . . . . . black PVC compound FI, CE Identification of cores Rated voltage Phase conductors brown, black, grey and neutral conductor blue. According to HD 308 S2:2002. Fire resistance class IEC 60332-3 cat B Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-3 U0/U = 0,6/1 kV, Um = 1,2 kV 32 | Draka Keila Cables Temperature range Marking Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying . . –15˚C Manufacturer, product name, date of manufacture, outer sheath material designation, meter marking Product Catalogue Power cables MCMK 4 1/2-core 1 kV power cable with PVC insulated copper conductors Basic cable data EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short phase and neutral conductor (4) circuit current for 1 second PE conductor (5) Basic cable data EAN code Construction data External cable diameter (1) Weight (1) copper cable Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Minimum permissible bending radius during laying Minimum permissible bending radius at final installation (3) Maximum permissible pulling force with a pulling grip Maximum permissible pulling force with a pulling eye Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In air conductor 70˚C In ground conductor 70˚C Short circuit currents (2) Maximum permissible short phase and neutral conductor (4) circuit current for 1 second PE conductor (5) 4x25/16 AN 1 kV 64 100+ 06 018 58-1 4x35/16 AN 1 kV 06 018 59-8 4x50/25 AN 1 kV 06 018 60-4 4x70/35 AN 1 kV 06 018 61-1 4x95/50 AN 1 kV 06 018 62-8 mm kg/km kg/km 26 1020 1450 28 1350 1850 32 1870 2500 35 2670 3450 41 3700 4750 m kg 500 K11 780 500 K12 1020 500 K14 1370 500 K16 1920 500 K18 2610 m m kN kN 0,32 0,22 1,5 10,0 0,34 0,24 2,1 14,0 0,39 0,28 3,0 20,0 0,42 0,30 4,2 20,0 0,50 0,35 5,7 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,727 0,87 1,15 0,28 0,40 0,524 0,63 1,15 0,27 0,45 0,387 0,46 0,727 0,27 0,50 0,268 0,32 0,524 0,26 0,55 0,193 0,23 0,387 0,26 0,65 A A 107 130 135 160 160 190 200 240 245 285 kA kA 2,8 2,7 4,0 2,7 5,7 4,4 8,0 5,7 10,9 7,2 4x120/70 AN 1 kV 64 100+ 06 018 63-5 4x150/70 AN 1 kV 06 018 64-2 4x185/95 AN 1 kV 06 018 65-9 4x240/120 AN 1 kV 06 018 66-6 4x300/150 AN 1 kV 06 018 67-3 mm kg/km kg/km 44 4740 5900 49 5710 7150 54 7230 8950 60 9450 12000 66 11900 14500 m kg 500 K20 3300 500 K22 4000 500 K22 4900 500 K24 6500 500 K24 7750 m m kN kN 0,53 0,37 7,2 20,0 0,59 0,42 8,5 20,0 0,65 0,46 8,5 20,0 0,72 0,51 8,5 20,0 0,8 0,56 8,5 20,0 Ω/km Ω/km Ω/km mH/km µF/km 0,153 0,19 0,268 0,26 0,70 0,124 0,15 0,268 0,26 0,70 0,0991 0,12 0,193 0,26 0,85 0,0754 0,097 0,153 0,26 0,80 0,0601 0,080 0,124 0,26 0,80 A A 280 325 320 370 365 420 425 480 490 550 kA kA 13,7 10,4 17,2 10,4 21,2 13,4 27,5 16,6 34,4 19,2 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C. Product Catalogue Draka Keila Cables | 33 Power cables MCMO Control cable Application Bending radius Cables for control, measuring and signal circuits of electrical equipment for fixed surface or flush-mounted installations, indoors, outdoors and protected underground. The concentric copper conductor forms a good electromechanical protection and a moderate protection against electrical interference. Minimum recommended bending radius - during installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D - in a final installation if bent only once . . . . . . . . . . . . . 8D Maximum permissible tensile stress during installation . . . . . . . . . . . . . . . . . . . . . .Ax50 N/mm2 Standard SFS 3713 Certificate / approval Construction Conductor . . . . . . . . . . . annealed copper wire Insulation . . . . . . . . . . . . black lead-free PVC, core identification by numbers Filling . . . . . . . . . . . . . . . filling compound Concentric conductor . . a layer of copper wires and an open helix of parallel copper wires Sheath . . . . . . . . . . . . . . black lead-free PVC CE, FI (FIMKO) Temperature range Maximum permissible temperature of conductor - in continuous use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70˚C - in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . –15˚C Number of conductors and cross section n x mm2 EAN code (SSTL code) Nominal overall diameter Total weight Direct current resistance at +20˚C max. 64 100+ mm kg/km conductor Ω/km concentric conductor Ω/km drum m Standard delivery length Electrical properties Capacitance between two adjacent conductors at +20˚C and 50 Hz Capacitance between one conductor and earth at +20˚C and 50 Hz µF/km µF/km Number of conductors and cross section n x mm2 EAN code (SSTL code) Nominal overall diameter Total weight Direct current resistance at +20˚C max. 64 100+ mm kg/km conductor Ω/km concentric conductor Ω/km drum m Standard delivery length Electrical properties Capacitance between two adjacent conductors at +20˚C and 50 Hz Capacitance between one conductor and earth at +20˚C and 50 Hz 34 | Draka Keila Cables µF/km µF/km 7 x 1,5 06 019 01-4 15 350 12,1 3,08 500/8E 12 x 1,5 06 019 02-1 19 500 12,1 3,08 400/8E 19 x 1,5 06 019 03-8 22 680 12,1 3,08 500/11G 27 x 1,5 06 019 04-5 26 900 12,1 3,08 500/11G 37 x 1,5 06 019 05-2 28 1150 12,1 2,6 400/11G 130 – 160 200 – 270 130 – 160 200 – 270 130 – 160 200 – 270 130 – 160 200 – 270 130 – 160 200 – 270 7 x 2,5 06 019 21-2 18 450 7,41 3,08 500/8E 12 x 2,5 06 019 22-9 22 690 7,41 3,08 500/11G 19 x 2,5 06 019 23-6 25 950 7,41 3,08 500/11G 27 x 2,5 06 019 24-3 29 1300 7,41 2,6 400/11G 130 – 160 210 – 280 130 – 160 210 – 280 130 – 160 210 – 280 130 – 160 210 – 280 Product Catalogue Power cables ARLC Aluminum Road Lighting Cable 1 kV outdoor lighting power cable with aluminum conductors and copper signal conductor Application Certificate/approval Fixed outdoor installations, ideal for laying in soil. CE Highest permissible conductor temperature upon continuous load . . . . . . . . . . . . . . . . . . . . . . . . . .90˚C Highest permissible conductor temperature upon short circuit (up to 5 s).. . . . . . . . . . . . . . . . . . .250˚C Lowest permissible temperature during laying . . . –15˚C Identification of cores Construction Conductor . . . . . . . 16 mm2 – round single-wire aluminium conductor; 25–35 mm2 – round stranded, compacted and annealed aluminium conductor Signal conductor . . 2,5 mm2 – round single-wire copper conductor Insulation . . . . . . . . black Laying up . . . . . . . . four insulated conductors stranded together Sheath . . . . . . . . . . black halogen-free self-extinguishing PE compound; insulation and sheath are UV (1) resistible and they don’t need extra protection against sunlight. 1) Product Catalogue Phase conductors. . . . . brown, black, grey PEN conductor . . . . . . . yellow-green Signal conductor . . . . . black Standards HD 603-5D S1, IEC 60502-1, IEC 60332-1 Cat. B, HD 308 S2:2002 Rated voltage U0/U = 0,6/1 kV Um = 1,2 kV Marking Manufacturer, product name, year/week of manufacture, outer sheath material, meter marking UV – ultraviolet radiation Draka Keila Cables | 35 Power cables EX 1 kV aerial bundled cable Application Construction Overhead distribution cable. Certificate/approval Conductor . . . . . . . . . . . round, stranded and compacted aluminium conductor Insulation . . . . . . . . . . . . black UV (1) and weather resistant PE compound Laying up . . . . . . . . . . . . insulated conductors are stranded together CE Identification of cores Rated voltage U0/U = 0,6/1 kV, Um = 1,2 kV Phase conductors. . . . . 1, 2 or 3 longitudinal ridges Neutral conductor . . . . no ridges Temperature range Marking Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 135˚C Manufacturer, year of manufacture. Standards HD 626-3I Basic cable data Construction data Insulation thickness Diameter (1) Weight (1) Delivery data Standard delivery length Drum Mechanical data (2) Minimum tensile strength Electrical data (2) Maximum DC resistance of 1) 36 | Draka Keila Cables aluminium conductor 20˚C 2x25 1 kV 4x25 1 kV 4x50 1 kV 4x95 1 kV mm mm kg/km 1,3 19 205 1,3 22 405 1,4 28 700 1,6 38 1350 m 500 K8 500 K9 500 K11 500 K14 kN 4,1 4,1 7,3 13,7 Ω/km 1,20 1,20 0,641 0,320 UV – ultraviolet radiation Product Catalogue Power cables AMKA 1 kV aerial bundled self supporting cable Application Construction For overhead distribution as part of AMKA system. Messenger is used as PEN conductor. The cable can have one optional conductor for street lighting. Rated voltage Conductor . . . . . . . . . . . 16 mm2 – round and solid aluminium conductor; 25–120 mm2 – round, stranded and compacted aluminium conductor Insulation . . . . . . . . . . . . black UV (1) and weather resistant PE compound Messenger . . . . . . . . . . . round, stranded and compacted aluminium alloy conductor Laying up . . . . . . . . . . . . insulated conductors are laid up around the messenger U0/U = 0,6/1 kV, Um = 1,2 kV Identification of cores Temperature range Phase conductors. . . . . 2, 3 or 4 longitudinal ridges Optional conductor . . . no ridges Standards SFS 2200, HD 626-5D S1 Certificate/approval FI (SGS FIMKO), CE Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 135˚C Lowest recommended temperature during laying. . . –20˚C Basic cable data Construction data Diameter over bare conductor Diameter over messenger Effective diameter in wind Weight aluminium cable Delivery data Standard delivery length Drum Total weight cable + drum Mechanical data Minimum permissible bending radius during laying Minimum permissible bending radius at final installation Minimum tensile strength of the messenger Initial modulus of elasticity of messenger Final modulus of elasticity of messenger Coefficient of linear expansion of messenger Electrical data Maximum DC resistance of phase conductor 20˚C AC resistance of phase conductor 70˚C Maximum DC resistance of of messenger conductor 20˚C Inductance Current ratings In air conductor 70˚C Short circuit currents Maximum permissible short circuit phase conductor current for 1 second messenger 1) Product Catalogue Marking Manufacturer, year of manufacture. 1x16+25 1 kV 3x16+25 4x16+25 3x25+35 3x35+50 3x50+70 3x70+95 3x120+95 1 kV 1 kV 1 kV 1 kV 1 kV 1 kV 1 kV mm mm mm kg/km kg/km 4,4 5,8 11 100 135 4,4 5,8 20 185 270 4,4 5,8 22 225 330 5,8 6,8 23 285 390 6,8 8,0 27 390 530 8,0 9,6 31 540 700 9,6 11,3 36 775 1000 12,7 11,3 42 1185 1500 m 2000 K11 325 1000 K12 360 1000 K14 445 1000 K14 505 1000 K16 725 1000 K18 930 500 K14 695 500 K18 980 m m kN N/mm 2 N/mm2 1/K 0,28 0,20 7,4 0,42 0,30 7,4 0,42 0,30 7,4 0,50 0,35 10,3 0,58 0,41 14,2 55000 63000 23x10-6 0,66 0,47 20,6 0,78 0,55 27,9 0,92 0,65 27,9 Ω/km Ω/km Ω/km mH/km 1,91 2,3 1,38 0,29 1,91 2,3 1,38 0,35 1,91 2,3 1,38 0,35 1,20 1,4 0,986 0,34 0,868 1,0 0,720 0,34 0,641 0,77 0,493 0,33 0,443 0,53 0,363 0,31 0,253 0,30 0,363 0,30 A 75 70 70 95 115 140 180 250 kA kA 1,0 1,5 1,0 1,5 1,0 1,5 1,6 2,1 2,3 3,0 3,2 4,3 4,5 5,9 7,8 5,9 kg UV – ultraviolet radiation Draka Keila Cables | 37 Power cables AHXAMK-W 6/10 (12) kV 10 kV power cable Application fields Design Suitable for cable ducts, outdoors, underground and in water. Radial and longitudinal water sealed. Cable can be installed by ploughing. Conductor . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2 longitudinal watertight Conductor screen. . extruded Insulation . . . . . . . . XLPE, nominal thickness = 3,4 mm Insulation screen . . extruded, bonded Bedding . . . . . . . . . semiconductive water-blocking tape Screen . . . . . . . . . . aluminium foil bonded tightly to sheath Sheath . . . . . . . . . . black UV (1) resistant LLD PE Centre conductor. . round, stranded and compacted copper conductor, acc. to IEC 60228 class 2 Laying up . . . . . . . . three cores are stranded around the centre conductor Standard CENELEC HD 620 Part 5 Section F Impulse voltage 75 kV Flame propagation class The PE jacket is not flame-resistant. Temperature range Highest permissible conductor temperature in continuous operation . . . . . . . . . . . . . . . . . . . . . . . .90˚C Lowest temperature during installation . . . . . . . . . . –20˚C below 0˚C special precaution shall be taken Marking E.g. AHXAMK-W 6/10kV 3X240+70Cu DRAKA SE “year”. Bending radius At laying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D When installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D Number of cores x cross section of conductor Diameter over insulation Single cable diameter (approx.) Complete cable diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Electrical data Resistance of conductor Resistance of centre conductor Inductance Reactance Capacitance Charging current mm2 mm mm mm kg/100 m m 3x95Al+35Cu 19,5 28 60 250 500 K24 3x120Al+35Cu 21 29 62 275 500 K26 3x150Al+35Cu 22,5 31 66 315 500 K26 3x185Al+35Cu 25 33 71 355 500 K26 3x240Al+35Cu 27,1 35 88 405 500 K26 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,320 0,524 0,31 0,10 0,30 0,7 0,253 0,524 0,30 0,10 0,32 0,7 0,206 0,524 0,29 0,09 0,35 0,8 0,164 0,524 0,28 0,09 0,40 0,9 0,125 0,524 0,27 0,09 0,43 0,9 1) UV – ultraviolet radiation Nominal values unless otherwise specified. 38 | Draka Keila Cables Product Catalogue Power cables AHXAMK-W 12/20 (24) kV 20 kV power cable Application fields Impulse voltage Suitable for cable ducts, outdoors, underground and in water. Radial and longitudinal water sealed. Can be installed by ploughing. 125 kV Design Standard CENELEC HD 620 Part 5 Section F Flame propagation class The PE-jacket is not flame-resistant. Temperature range Highest permissible conductor temperature in continuous operation . . . . . . . . . . . . . . . . . . . . . . . .90˚C Lowest temperature during installation . . . . . . . . . . –20˚C below 0˚C special precaution shall be taken Bending radius At laying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D When installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D Number of cores x cross section of conductor Diameter over insulation Single cable diameter (approx.) Complete cable diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Electrical data Resistance of conductor Resistance of centre conductor Inductance Reactance Capacitance Charging current Standard drum size Electrical data Resistance of conductor Resistance of centre conductor Inductance Reactance Capacitance Charging current Marking Eg. AHXAMK-W 12/20kV 3X240+70Cu DRAKA SE “year”. mm2 mm mm mm kg/100 m m 3x50Al+35Cu 20,5 28 60 240 500 K24 3x70Al+35Cu 22,8 29 65 265 500 K24 3x95Al+35Cu 24,5 32 70 305 500 K24 3x120Al+35Cu 25,8 33 72 330 500 K26 3x150Al+35Cu 26,6 34 75 375 500 K26 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,641 0,524 0,39 0,12 0,16 0,7 0,443 0,524 0,42 0,13 0,18 0,7 0,320 0,524 0,40 0,13 0,21 0,8 0,253 0,524 0,39 0,12 0,22 0,8 0,206 0,524 0,37 0,12 0,24 0,9 Number of cores x cross section of conductor Diameter over insulation Single cable diameter (approx.) Complete cable diameter (approx.) Weight (approx.) Standard delivery length Conductor . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2 longitudinal watertight Conductor screen. . . extruded Insulation . . . . . . . . . XLPE, nominal thickness 5,5 mm Insulation screen . . . extruded, bonded Bedding . . . . . . . . . . semiconductive water-blocking tape Screen . . . . . . . . . . . aluminium foil bonded tightly to sheath Sheath . . . . . . . . . . . black UV (1) resistant LLD PE Centre conductor . . . round, stranded and compacted copper conductor, acc. to IEC 60228 class 2 Laying up . . . . . . . . . three cores are stranded around the centre conductor mm2 mm mm mm kg/100 m m 3x185Al+35Cu 29,0 36 80 420 500 K26 3x240Al+35Cu 30,5 39 86 500 500 K28 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,164 0,524 0,36 0,11 0,26 1,0 0,125 0,524 0,35 0,11 0,29 1,1 3x240Al+70Cu 3x300Al+70Cu 33 43 94 88 530 625 500 500 K28 K28 31,3 39 0,125 0,268 0,35 0,11 0,29 1,1 0,100 0,268 0,34 0,11 0,32 1,2 1) UV – ultraviolet radiation Nominal values unless otherwise specified. Product Catalogue Draka Keila Cables | 39 Power cables AXLJ-TT 7/12 kV 10 kV power cable Application fields Bending radius Single core distribution cable suitable for laying outdoors in 1- or 3-phase formation. Installation in pipes and in ground/water. Both radial and longitudinal water sealed. Can be installed by ploughing. At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Alternative designation Design Conductor���������������������� stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen���������� extruded Insulation������������������������ XLPE, min. thickness= 2,96 mm Insulation screen���������� extruded bonded Longitudinal water sealing���������������������������� swellable conducting tape Concentric conductor���� annealed copper wires Radial water sealing������ aluminium PE laminate Sheath���������������������������� black UV (1) resistant LLD PE SE-N10XC7A5T5E-AR Standard SS 424 14 16 CENELEC HD 620 Part 5 Section K Fire propagation class F1 acc. to SS 424 14 75 Material declaration AXLJ-TT Marking Impulse voltage E.g. AXLJ-TT 08DRAKA TSLE 12kV 1X240 AFR/25 “Date”, meter marked. 75 kV Temperature range In continuous operation max. conductor temp.. . . . 90˚C Lowest cable temperature under installation. . . . . –20˚C below 0˚C special precaution shall be taken Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length mm2 mm mm kg/100 m m Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance in trefoil/flat formation (2) (3) Reactance Capacitance Earth fault current 1x50/16 16,0 23,3 59,7 500 K11 0070410 1x95/16 19,3 26,6 79,4 500 K12 0070420 1x150/25 22,2 29,7 107,4 500 K12 0070440 1x240/25 26,1 33,8 141,4 500 K14 0070460 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,641 1,2 0,40/0,73 0,29 0,23 1,5 0,320 1,2 0,36/0,66 0,21 0,30 2,0 0,206 0,8 0,34/0,63 0,20 0,35 2,3 0,125 0,8 0,31/0,58 0,18 0,43 2,8 Electrical data Current rating at core temp. 65˚C in ground (3) Current rating at core temp. 65˚C in air (3) Current rating at core temp. 90˚C in air (3) Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C A A A kA kA 170 165 205 5,1 4,7 250 255 310 9,7 9,0 315 325 395 15,3 14,2 395 420 515 24,4 22,7 Nominal values unless otherwise specified. 1) UV – ultraviolet radiation 2) Cable distance, installation flat formation = 70 mm. 3) Trefoil with screen grounded in both ends. 40 | Draka Keila Cables Product Catalogue Power cables AXLJ-TT 14/24 kV 20 kV power cable Application fields Bending radius Single core, distribution cable for outdoors use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water sealed. Can be installed by ploughing. At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Alternative designation Design AXLJ-TT Conductor���������������������� stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen���������� extruded Insulation������������������������ XLPE, min. thickness = 4,85 mm Insulation screen���������� extruded bonded Longitudinal water sealing���������������������������� swellable conducting tape Concentric conductor���� annealed copper wires Radial water sealing������ aluminium PE laminate Sheath���������������������������� black UV (1) resistant LLD PE Impulse voltage Marking 125 kV E.g. AXLJ-TT 08DRAKA TSLE 24 kV 1X150 AFR/25 “year”, meter marked. SE-N20XC7A5T5E-AR Standard CENELEC HD 620 Part 5 Section K Fire propagation class F1 acc. to SS 424 14 75 Material declaration Temperature range In continuous operation max. conductor temp. . . . . 90˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken. Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance in trefoil/flat formation (2) (3) Reactance Capacitance Earth fault current Electrical data Current rating at core temp. 65˚C in ground (3) Current rating at core temp. 65˚C in air (3) Current rating at core temp. 90˚C in air (3) Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C mm2 mm mm kg/100 m m 1x50/16 20,4 27,7 70,6 500 K12 1205011702 1x95/16 23,7 31,2 98,5 500 K12 0070520 1x150/25 26,6 34,3 120,5 500 K14 1205012102 1x240/25 30,5 38,6 165,2 500 K16 0070560 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,641 1,2 0,44/0,74 0,23 0,17 2,2 0,320 1,2 0,39/0,67 0,21 0,20 2,6 0,206 0,8 0,37/0,63 0,20 0,24 3,2 0,125 0,8 0,34/0,59 0,19 0,29 3,8 A A A kA 170 165 205 5,1 250 255 310 9,7 315 325 395 15,3 395 420 515 24,4 kA 4,7 9,0 14,2 22,7 Nominal values unless otherwise specified. 1) UV – ultraviolet radiation 2) Cable distance, installation flat formation = 70 mm 3) Trefoil with screen grounded in both ends Product Catalogue Draka Keila Cables | 41 Power cables AXLJ-TTCL TSLF 14/24 kV 20 kV power cable Application fields Bending radius Single core and three core, distribution cable for outdoors use in three phase formation. Installation in pipes and ground/water. Both radial and longitudinal water sealed. Can be ploughed down. Possibility for electric testing of sheath and detecting of damages due to semiconductive outer layer. At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Alternative designation 125 kV Conductor���������������������� stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen���������� extruded Insulation������������������������ XLPE, nom. thickness = 5,5 mm Insulation screen���������� extruded bonded Longitudinal water sealing���������������������������� swellable conducting tape Concentric conductor���� annealed copper wires Radial water sealing������ aluminium PE laminate, bonded to sheath Sheath���������������������������� LLD PE, natural Semiconductive layer���� black UV (1) resistant, extruded bonded to the outer sheath Laying up 3-core����������� three stranded single core cables Temperature range Marking In continuous operation max. conductor temp. . . . . 90˚C Lowest cable temperature during laying. . . . . . . . . –20˚C and below 0˚C special precaution shall be taken E.g. AXLJ-TTCL 08DRAKA TSLF 24 kV 1X150 AFR/25 “year”, meter marked. SE-N20XC7A5T5E-AR Standard CENELEC HD 620 Part 5 Section K Fire propagation class F1 acc. to SS 424 14 75 Material declaration AXLJ-TT Impulse voltage Number of cores x cross section of conductor mm2 Diameter over insulation mm Thickness of sheath mm Overall diameter (approx.) mm Weight (approx.) kg/100 m Standard delivery length m Standard drum size Electrical data at +20˚C Conductor resistance Ω/km Screen resistance Ω/km Inductance in trefoil/flat formation (2) (3) mH/km Reactance in trefoil/flat formation (2) (3) Ω/km Capacitance µF/km Charging current A/km Current ratings Current rating at core - temp. 65˚C in ground (3) A - temp. 65˚C in air (3) A - temp. 90˚C in air (3) A Max. short circuit current on the conductor - during 1 s at initial temp. 65˚C kA - during 1 s at initial temp. 90˚C kA Design 1x50/16 20,4 1,8 29 71 500 K12 1x95/25 23,7 1,9 32 100 500 K12 1x150/25 26,6 2,0 35 121 500 K14 1x240/35 30,5 2,2 40 167 500 K16 1x400/35 36,0 2,3 45 228 500 K18 3x1x50/16 20,4 1,8 60 210 500 K24 3x1x95/25 23,7 1,9 69 295 500 K26 3x1x150/25 26,6 2,0 75 360 500 K26 3x1x240/35 30,5 2,2 84 510 500 K28 0,641 1,15 0,44/0,74 0,14/0,23 0,17 0,6 0,320 0,727 0,39/0,67 0,12/0,21 0,20 0,8 0,206 0,727 0,37/0,63 0,12/0,20 0,24 0,9 0,125 0,524 0,34/0,59 0,11/0,19 0,29 1,1 0,0778 0,524 0,32/0,55 0,10/0,17 0,36 1,4 0,641 1,15 0,44 0,14 0,17 0,6 0,320 0,727 0,39 0,12 0,20 0,8 0,206 0,727 0,37 0,12 0,24 0,9 0,125 0,524 0,34 0,11 0,29 1,1 170 160 195 250 230 280 315 300 370 395 400 490 525 555 680 170 160 195 250 230 280 315 300 370 395 400 490 5,2 4,7 9,9 8,9 15,6 14,2 25,0 22,7 41,6 37,8 5,2 4,7 9,9 8,9 15,6 14,2 25,0 22,7 1) UV – ultraviolet radiation 2) Cable distance, installation flat formation = 70 mm 3) Trefoil with screen grounded in both ends 42 | Draka Keila Cables Product Catalogue Power cables AXLJ-TT 7/12 kV (3-core) 10 kV power cable Application fields Temperature range Three core cable designed for replacement of bare overhead lines outdoors. Primary developed to be ploughed down but thanks to the robust design the cable can stand the stresses that appears when laying in lake with calm water and limited deep. The design with water swellable yarn and aluminium foil bonded to the sheath makes the cable radial and longitudinal water sealed. In continuous operation max. conductor temp. . . . . 90˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken Alternative designation Bending radius At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Design SE-N10XC7A5T5E-AR Conductor���������������������� stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen���������� extruded Insulation������������������������ XLPE, min. thickness = 2,96 mm Insulation screen���������� extruded bonded Longitudinal water sealing���������������������������� swellable conducting tape and water swellable yarn Concentric conductor�� annealed copper wires Radial water sealing������ aluminium foil bonded to the sheath Sheath���������������������������� black UV (1) resistant LLD PE Standards SS 424 14 16, CENELEC HD 620 Part 6 Section M Fire propagation class F1 acc. to SS 424 14 75 Material declaration AXLJ-TT Impulse voltage 75 kV Marking E.g. AXLJ-TT 7/12kV 3X95/16 DRAKA SE “Date”, meter marked. Number of cores x cross section of conductor Diameter over insulation Overall diameter single core (approx.) Overall diameter whole cable (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current mm2 mm mm mm kg/100 m m 3x25/16 13,9 14,9 37,6 108,1 500 K16 0071000 3x50/16 16,0 17 42,3 142,0 500 K18 0071010 3x95/16 19,3 20,3 49,8 202,9 500 K20 0071020 3x150/25 22,2 23,2 56,7 279,3 500 K22 0071030 3x240/25 26,1 27,1 65,5 384,2 500 K24 0071040 Ω/km Ω/km mH/km Ω/km µF/km A/km 1,2 1,2 0,37 0,12 0,19 0,4 0,641 1,2 0,34 0,11 0,23 0,4 0,320 1,2 0,31 0,10 0,30 0,6 0,206 0,8 0,29 0,09 0,35 0,7 0,125 0,8 0,27 0,09 0,43 0,8 A A A kA 100 90 110 2,5 145 130 160 5,1 205 190 230 9,7 260 250 305 15,3 340 330 400 24,4 kA 2,3 4,7 9,0 14,2 22,7 kA - 55 65 70 70 1) UV – ultraviolet radiation Nominal values unless otherwise specified. Product Catalogue Draka Keila Cables | 43 Power cables AXLJ-TT 14/24 kV (3-core) 20 kV power cable Application fields Impulse voltage Three core cable designed for replacement of bare overhead lines outdoors. Primary developed to be ploughed down but thanks to the robust design the cable can stand the stresses that appears when laying in lake with calm water and limited deep. The design with water swellable yarn and aluminium foil bonded to the sheath makes the cable radial and longitudinal water sealed. 125 kV Alternative designation SE-N20XC7A5T5E-AR Standard CENELEC HD 620 Part 6 Section M Fire propagation class F1 acc. to SS 424 14 75 Temperature range In continuous operation max. conductor temp. . . . . 90˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken Bending radius At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Design Conductor������������������������stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen ����������extruded Insulation��������������������������XLPE, min. thickness = 4,85 mm Insulation screen������������extruded bonded Longitudinally water sealed��������������������������������swellable conducting tape and water swellable yarn Concentric conductor����annealed copper wires Radial water sealing������aluminium foil bonded to the sheath Sheath������������������������������black UV (1) resistant LLD PE Marking E.g. AXLJ-TT 14/24 kV 3x95/16 DRAKA SE “Date”, meter marked. Material declaration AXLJ-TT Number of cores x cross section of conductor Diameter over insulation Overall diameter single core (approx.) Overall diameter whole cable (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current mm2 mm mm mm kg/100 m m 3x25/16 18,1 18,9 47,2 155,4 500 K20 0071050 3x50/16 20,2 21,0 52,2 194,6 500 K20 0071060 3x95/16 23,5 24,3 59,7 266,9 500 K24 0071070 3x150/25 26,4 27,2 66,3 344,2 500 K24 0071080 3x240/25 30,3 31,1 75,3 461,5 500 K26 0071090 Ω/km Ω/km mH/km Ω/km µF/km A/km 1,2 1,2 0,42 0,13 0,14 0,5 0,641 1,2 0,38 0,12 0,17 0,6 0,320 1,2 0,34 0,11 0,20 0,8 0,206 0,8 0,32 0,10 0,24 0,9 0,125 0,8 0,30 0,09 0,29 1,1 A A A kA 100 90 110 2,5 145 130 160 5,1 205 190 230 9,7 260 250 305 15,3 340 330 400 24,4 kA 2,3 4,7 9,0 14,2 22,7 kA - 55 65 70 70 1) UV – ultraviolet radiation Nominal values unless otherwise specified. 44 | Draka Keila Cables Product Catalogue Power cables AXLJ-RMF 7/12 kV 10 kV power cable Application fields Impulse voltage Three core cable designed for replacement of bare overhead lines outdoors. Primary developed to be ploughed down but thanks to the robust design it can stand the stresses that appears when laying in water. 75 kV Alternative designation SE-N10XC7V-AR Bending radius At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Design Standards AXLJ LT, -F, -RMF Conductor . . . . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen . . . . . extruded Insulation . . . . . . . . . . . . XLPE, min. thickness = 2,96 mm Insulation screen . . . . . extruded bonded Taping . . . . . . . . . . . . . . . conductive tape Concentric conductor. . annealed copper wires Sheath . . . . . . . . . . . . . . black UV (1) resistant LLD PE Temperature range Marking In continuous operation max. conductor temp . . . . .90˚C Lowest cable temperature under installation . . . . . –20˚C and below 0˚C special precaution shall be taken E.g. AXLJ-RMF 7/12 KV 3X150/25 LT DRAKA SE “year”. S 424 14 16 CENELEC HD 620 Part 6 Section M Fire propagation class F1 acc. to SS 424 14 75 Material declaration Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current mm2 mm mm kg/100 m m 3x25/16 14,0 39,1 103,5 500 K16 1040031502 3x50/16 16,2 44,0 135,4 500 K18 1040031702 3x95/16 19,5 51,6 195,1 500 K20 1040031902 3x150/25 22,4 58,4 267,1 500 K22 1040032102 3x240/25 26,3 67,2 372,8 500 K24 1040032302 Ω/km Ω/km mH/km Ω/km µF/km A/km 1,2 1,2 0,38 0,12 0,19 0,4 0,641 1,2 0,34 0,11 0,23 0,4 0,320 1,2 0,31 0,10 0,30 0,6 0,206 0,8 0,29 0,09 0,35 0,7 0,125 0,8 0,27 0,09 0,42 0,8 A A A kA 100 90 110 2,5 145 130 160 5,1 205 190 230 9,7 260 250 305 15,3 340 330 400 24,4 kA 2,3 4,7 9,0 14,2 22,7 kA - 55 65 70 70 1) UV – ultraviolet radiation Nominal values unless otherwise specified. Product Catalogue Draka Keila Cables | 45 Power cables AXLJ-RMF 14/24 kV 20 kV power cable Application fields Impulse voltage Three core cable designed for replacement of bare overhead lines outdoors. Primary developed to be ploughed down but thanks to the robust design it can stand the stresses that appears when laying in water. 125 kV Alternative designation SE-N20XC7V-AR Bending radius At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Design Standards S 424 14 16, CENELEC HD 620 Part 6 Section M Fire propagation class F1 acc. to SS 424 14 75 Temperature range Conductor . . . . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen . . . . . extruded Insulation . . . . . . . . . . . . XLPE, min. thickness = 4,85 mm Insulation screen . . . . . extruded bonded Taping . . . . . . . . . . . . . . . conductive tape Concentric conductor . . annealed copper wires Sheath . . . . . . . . . . . . . . black UV (1) resistant LLD PE In continuous operation max. conductor temp . . . . .90˚C Lowest cable temperature under installation . . . . . –20˚C and below 0˚C special precaution shall be taken Marking Material declaration E.g. AXLJ-RMF 14/24 KV 3X150/25 LT DRAKA SE “year”. AXLJ LT, -F, -RMF Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current mm2 mm mm kg/100 m m 3x25/16 18,2 49,0 147,2 500 K20 1045031502 3x50/16 20,4 53,9 185,1 500 K20 1045031702 3x95/16 23,7 61,4 253,9 500 K24 1045031902 3x150/25 26,7 68,1 328,1 500 K24 1045032102 3x240/25 30,7 77,1 445,5 500 K26 1045032302 Ω/km Ω/km mH/km Ω/km µF/km A/km 1,2 1,2 0,43 0,14 0,14 0,5 0,641 1,2 0,39 0,12 0,16 0,6 0,320 1,2 0,35 0,11 0,20 0,8 0,206 0,8 0,32 0,10 0,24 0,9 0,125 0,8 0,30 0,09 0,29 1,1 A A A kA 100 90 110 2,5 145 130 160 5,1 205 190 230 9,7 260 250 305 15,3 340 330 400 24,4 kA 2,3 4,7 9,0 14,2 22,7 kA - 55 65 70 70 1) UV – ultraviolet radiation Nominal values unless otherwise specified. 46 | Draka Keila Cables Product Catalogue Power cables AXQJ-RMF 7/12 kV 10 kV halogen-free power cable Application fields Material declaration Halogen-free and fire classified cable. No emittance of corrosive gases, low smoke density in case of fire. Primary developed for installation indoors, tunnels etc. The cable can also with advantage be installed outdoors and in ground. Ploughing down is not recommended. AXQJ-F, –RMF Alternative designation Standards Bending radius Design SS 424 14 16 CENELEC HD 620 Part 6 Section M CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Conductor . . . . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen . . . . . extruded Insulation . . . . . . . . . . . . XLPE, min. thickness = 2,96 mm Insulation screen . . . . . extruded bonded Taping . . . . . . . . . . . . . . . conductive tape Concentric conductor. . annealed copper wires Sheath . . . . . . . . . . . . . . halogen-free compound, black Fire propagation class F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and SS-EN 50266-2-3 Temperature range In continuous operation max. conductor temp . . . . .90˚C Lowest cable temperature under installation . . . . . –20˚C and below 0˚C special precaution shall be taken. Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current 75 kV At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D SE-N10XC7Z1-AR Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Impulse voltage Marking E.g. AXQJ-RMF 7/12 kV 3x150/25 LT F4B DRAKA SE “Date”, meter marked. mm2 mm mm kg/100 m m 3x50/16 16,0 43,6 153,2 500 K18 0071210 3x95/16 19,3 51,1 219,4 500 K20 0071220 3x150/25 22,2 58,0 297,3 500 K22 0071230 3x240/25 26,1 66,8 405,3 500 K24 0071240 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,641 1,2 0,34 0,11 0,23 0,4 0,320 1,2 0,31 0,10 0,30 0,6 0,206 0,8 0,29 0,09 0,35 0,7 0,125 0,8 0,27 0,09 0,43 0,8 A A A kA 145 130 160 5,1 205 190 230 9,7 260 250 305 15,3 340 330 400 24,4 kA 4,7 9,0 14,2 22,7 kA 55 65 70 70 Nominal values unless otherwise specified. Product Catalogue Draka Keila Cables | 47 Power cables AXQJ-RMF 14/24 kV 20 kV halogen-free power cable Application fields Material declaration Halogen-free and fire classified cable. No emittance of corrosive gases, low smoke density in case of fire. Primary developed for installation indoors, tunnels etc. The cable can also with advantage be installed outdoors and in ground. Ploughing down is not recommended. AXQJ-F, –RMF Alternative designation Standards Bending radius Design SS 424 14 16 CENELEC HD 620 Part 6 Section M CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Conductor . . . . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen . . . . . extruded Insulation . . . . . . . . . . . . XLPE, min. thickness = 4,85 mm Insulation screen . . . . . extruded bonded Taping . . . . . . . . . . . . . . . conductive tape Concentric conductor. . annealed copper wires Sheath . . . . . . . . . . . . . . halogen-free compound, black Fire propagation class F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and SS-EN 50266-2-3 Temperature range In continuous operation max. conductor temp . . . . .90˚C Lowest cable temperature under installation . . . . . –20˚C and below 0˚C special precaution shall be taken. Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current 125 kV At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D SE-N20XC7Z1-AR Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Impulse voltage Marking Eg. AXQJ-RMF 14/24 kV 3x150/25 LT F4B DRAKA SE “Date”, meter marked. mm2 mm mm kg/100 m m 3x50/16 20,2 53,5 210,2 500 K20 0071250 3x95/16 23,5 61,0 286,2 500 K24 0071260 3x150/25 26,4 67,6 367,0 500 K24 0071270 3x240/25 30,3 76,6 488,3 500 K26 0071280 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,641 1,2 0,38 0,12 0,17 0,6 0,320 1,2 0,34 0,11 0,20 0,8 0,206 0,8 0,32 0,10 0,24 0,9 0,125 0,8 0,30 0,09 0,29 1,1 A A A kA 145 130 160 5,1 205 190 230 9,7 260 250 305 15,3 340 330 400 24,4 kA 4,7 9,0 14,2 22,7 kA 55 65 70 70 Nominal values unless otherwise specified. 48 | Draka Keila Cables Product Catalogue Power cables AXQJ-F 7/12 kV 10 kV halogen-free power cable Application fields Material declaration Halogen-free and fire classified single core cable. No emittance of corrosive gases, low smoke density in case of fire. Distribution cable for indoors and outdoors use in 3-phase formation. Installation in pipes and ground. Ploughing down is not recommended. AXQJ-F, –RMF Alternative designation SE-N10XC7Z1-AR Standards SS 424 14 16 CENELEC HD 620 Part 5 Section K CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Fire propagation class F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and SS-EN 50266-2-3 Temperature range In continuous operation max. conductor temp . . . . .90˚C Lowest cable temperature under installation . . . . . –20˚C and below 0˚C special precaution shall be taken Impulse voltage 75 kV Bending radius At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Design Conductor . . . . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen . . . . . extruded Insulation . . . . . . . . . . . . XLPE, min. thickness = 2,96 mm Insulation screen . . . . . extruded bonded Concentric conductor. . annealed copper wires Sheath . . . . . . . . . . . . . . halogen-free compound, black Marking E.g. AXQJ-F 7/12 kV 1x630/35 F4B FASTSITTANDE SKIKT DRAKA SE “Date”, meter marked. Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance in trefoil/flat formation (1) (2) Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground (2) Current rating at core temp. 65˚C in air (2) Current rating at core temp. 90˚C in air (2) Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C mm2 mm mm kg/100 m m 1x240/25 26,1 33,5 149,4 500 K14 0071340 1x500/35 34,6 42,7 254,9 500 K18 0071370 1x630/35 38,7 46,9 302,4 500 K20 0071380 1x800/35 43,0 52,0 365,0 500 K22 Ω/km Ω/km mH/km 0,0605 0,6 0,28/0,52 0,16 0,59 1,1 0,0469 0,6 0,27/0,50 0,16 0,67 1,3 0,0367 0,524 0,27 Ω/km µF/km A/km 0,125 0,8 0,31/0,58 0,18 0,43 0,8 A A A kA kA 385 400 490 24,4 22,7 570 635 775 50,9 47,2 635 720 880 64,1 59,5 695 820 1010 83 75 0,16 0,75 1,4 Nominal values unless otherwise specified. 1) Cable distance, installation flat formation = 70 mm 2) Trefoil with screen grounded in both ends Product Catalogue Draka Keila Cables | 49 Power cables AXQJ-F 14/24 kV 20 kV halogen-free power cable Application fields Material declaration Halogen-free and fire classified single core cable. No emittance of corrosive gases, low smoke density in case of fire. Distribution cable for indoors and outdoors use in 3-phase formation. Installation in pipes and ground. Ploughing down is not recommended. AXQJ-F, –RMF Alternative designation SE-N20XC7Z1-AR Standard SS 424 14 16 CENELEC HD 620 Part 5 Section K CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Fire propagation class F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and SS-EN 50266-2-3 Temperature range In continuous operation max. conductor temp. . . . . 90˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken Impulse voltage 125 kV Bending radius At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Design Conductor���������������������� stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen���������� extruded Insulation������������������������ XLPE, min. thickness = 4,85 mm Insulation screen���������� extruded bonded Concentric conductor���� annealed copper wires Sheath���������������������������� halogen-free compound, black Marking E.g. AXQJ-F 14/24 kV 1x630/35 F4B FASTSITTANDE SKIKT DRAKA SE “Date”, meter marked. mm2 1x240/25 1x500/35 1x630/35 mm mm kg/100 m m 30,3 38,1 175,5 500 K16 0071440 38,8 47,3 287,5 500 K20 0071470 42,9 51,5 338,1 500 K20 0071480 Inductance in trefoil/flat formation (1) (2) Reactance Capacitance Charging current Ω/km Ω/km mH/km Ω/km µF/km A/km 0,125 0,8 0,34/0,59 0,19 0,29 1,1 0,0605 0,6 0,30/0,53 0,17 0,39 1,5 0,0469 0,6 0,29/0,51 0,16 0,43 1,6 0,0367 0,524 0,27 Electrical data Current rating at core temp. 65˚C in ground (2) Current rating at core temp. 65˚C in air (2) Current rating at core temp. 90˚C in air (2) Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C A A A kA kA 385 400 490 24,4 22,7 570 635 775 50,9 47,2 635 720 880 64,1 59,5 695 820 1010 83,0 75,0 Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance 1x800/35 63 52 365 500 K22 0,75 1,9 Nominal values unless otherwise specified. 1) Cable distance, installation flat formation = 70 mm. 2) Trefoil with screen grounded in both ends. 50 | Draka Keila Cables Product Catalogue Power cables PAS-W 20 kV Covered conductor PAS-W 20 kV Application Construction For pole installation as part of PAS-system. SFS 5791, EN 50397 Conductor . . . . . . . round, stranded and compacted watertight aluminium alloy conductor Covering. . . . . . . . . black weather resistant XLPE compound Rated voltage Marking U0/U = 12/20 kV, Um = 24 kV PAS, DRAKA, product name, year of manufacture, PEX. Temperature range Options Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . .80˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . 200˚C Lowest recommended temperature during laying. . . –20˚C PAS-W 30 kV is available by special order. Standards Basic cable data PAS-W 35 6,9 11,5 90 160 PAS-W 50 8,0 12,7 120 200 PAS-W 70 9,7 14,3 180 270 PAS-W 95 11,3 16,1 245 350 PAS-W 120 12,8 17,6 310 425 PAS-W 150 14,2 18,9 385 510 2000 K11 375 2000 K11 455 2000 K12 630 2000 K14 815 2000 K16 1045 2000 K16 1215 m m kN N/mm2 N/mm2 1/˚C 0,16 0,12 11,2 0,18 0,13 15,5 0,20 0,14 22,5 0,25 0,18 38 0,27 0,19 47,3 Ω/km Ω/km 0,986 1,22 0,720 0,89 0,493 0,61 0,363 0,45 0,288 0,36 0,236 0,29 A 200 245 310 370 430 485 kA 3,2 4,3 6,4 8,6 11,0 13,5 Diameter over conductor (1) Diameter over covered conductor (1) aluminium Weight (1) cable Delivery data Standard delivery length Drum mm mm kg/km kg/km Total weight (1) Mechanical data (2) Min. permissible bending radius during laying kg Min. permissible bending radius at final installation (3) Min. tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Maximum DC resistance of conductor (20˚C) AC resistance of conductor (80˚C) (1) Current ratings (2) In air (conductor 80˚C) Short circuit currents (2) Max. permissible short circuit current for 1 second (4) m 0,22 0,16 30,4 61,000 62,500 23 x 10-6 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C. Product Catalogue Draka Keila Cables | 51 Installation cables and wires ELECTRICAL PROPERTIES Current ratings for installation cables (PVC insulated cables according to HD 21) RATED VOLTAGE The rated voltage of cables is marked U0/U, where: U0 - rated voltage between the conductor and earth of metallic screen U - rated voltage between conductors. DIRECT CURRENT RESISTANCE OF CONDUCTORS HD 516 table 7a Cross section of conductors mm2 0,75 1,0 1,5 2,5 4 6 10 16 25 Current rating 2 cores load A 6 10 16 25 32 Current rating 3 cores load A 6 10 16 20 25 37 52 69 92 For each cable, the catalogue lists the maximum direct current resistance value for the conductor at a temperature of +20°C, permitted by the construction standard. The current in a conductor heats up the conductor. The rise in temperature increases the conductor’s resistance. The following table shows some pre-calculated correction factors for the direct current resistance of copper conductor. Assumptions for table are: - conductor temperature in PVC cable . . . . . . . . . . . . . . 70˚C - ambient air temperature . . . . . . . . . . . . . . . . . . . . . 30˚C Conductor temperature Correction factor Maximum continuous current in amps for PVC insulated control cables in air Uo/U=450/750 V. °C 20 1,0 40 60 1,079 1,157 70 1,196 80 90 1,236 1,275 CABLES CURRENT CARRYING CAPACITY Current carrying capacities of installation cables are given in HD 384.5.523 (or IEC 364-5-523). Electrical installation of buildings section 523: Current carrying capacities. Current rating tables are based on the requirements of the maximum permissible conductor temperatures in continuous use and assumed installation conditions. The correction factors must be used when the conditions differ from the installation conditions assumed in the current rating tables. Current ratings for control cables Number of conductors with load Copper conductor cross section, mm2 0,75 1,5 2,5 4 20 7 8 13 16 12 7 11 13 19 6 9 11 27 5 8 10 37 4 7 9 48 4 6 - Assumptions for table are: - conductor temperature in PVC cable . . . . . . . . . . . . . . 70˚C - ambient air temperature . . . . . . . . . . . . . . . . . . . . . 25˚C THE NEW COLOURS OF WIRES FOR CABLES BY CENELEC HD 308 S2:2002 STANDARD Renewed standard won’t bring substantial changes, yellow-green remains for fuse wire (PE) or combined fuse- and neutral (PEN); blue comes into use as the colour of the neutral wire (N) instead of light blue. But the colours of phase wires will change – grey will be taken into use in addition to black and brown. The sequence of colours will change, too – instead of black, brown will be the first colour of the phase wire. PPJ 3 core (3X...) PPJ 4 core (1,5 ja 2,5 mm2) AXPK PPJ 4 core (4–25 mm2) PPJ 5 core 1 (A)MCMK 1 2 3 4 core 1 MCMK 3 5 core 4 (A)MCMK 2 MSK, MSO, MSOY 2 core 2 3 core 4 3 MSK, MSO, MSOY 3 core 1 PPJ 2 core MSK, MSO, MSOY 4 core PPJ 3 core (3G...) MSK, MSO, MSOY 5 core 52 | Draka Keila Cables Product Catalogue Installation cables and wires PL / ML / H07V-U PVC-insulated solid conductor Application Temperature range For fixed installation in a conduit, and for wiring in appliances, switchgear and control gear with a maximum voltage of 1000 V (AC) or a maximum of 750 V (DC) to earth. Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . –25˚C Standards Bending radius EVS 719:1996, SFS 5523, CENELEC HD 21 During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . 8D In a final installation if bent only once min.. . . . . . . . . . 3D Certificate/approval Construction EEI, FI, <HAR> Rated voltage Conductor . . . . . . . . . . . annealed copper wire Insulation . . . . . . . . . . . . . . PVC, core identification by colours U0/U = 450/750 V Identification of cores PRU – brown, MU – black, SI – blue, KORO – yellow-green. Cross section of conductor and colour PL 1,5 MU PL 1,5 PRU PL 1,5 SI PL 1,5 KORO PL 2,5 MU PL 2,5 PRU PL 2,5 SI PL 2,5 KORO PL 4 MU PL 4 PRU PL 4 SI PL 4 KORO Product Catalogue EAN code (SSTL code) 64 100+ 04 012 03-1 04 012 02-4 04 012 07-9 04 012 09-3 04 012 23-9 04 012 22-2 04 012 27-7 04 012 29-1 04 012 43-7 04 012 42-0 04 012 47-5 04 012 49-9 Nominal overall diameter mm 2,7 2,7 2,7 2,7 3,3 3,3 3,3 3,3 3,9 3,9 3,9 3,9 Total weight kg/km 20 20 20 20 31 31 31 31 50 50 50 50 Direct current resistance of conductor at 20˚C max. Ω/km 12,1 12,1 12,1 12,1 7,41 7,41 7,41 7,41 4,61 4,61 4,61 4,61 Standard delivery length, coil m 200 200 200 200 200 200 200 200 200 200 200 200 Draka Keila Cables | 53 Installation cables and wires PK / MK / H07V-R PVC-insulated stranded conductor Application Temperature range For permanent installation in a conduit, and for wiring in appliances, switchgear and control gear with a maximum voltage of 1000 V (AC) or a maximum of 750 V (DC) to earth. Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . –25˚C Standards Bending radius EVS 718:1996, SFS 3103, CENELEC HD 21 During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D In a final installation if bent only once min.. . . . . . . . . . 3D Certificate/approval Construction EEI, FI, <HAR> Rated voltage Conductor . . . . . . . . . . . annealed copper wires, stranded Insulation . . . . . . . . . . . . PVC, core identification by colours U0/U = 450/750 V Identification of cores RU, PRU – brown, MU – black, KEVI, KORO – yellow-green, SI – blue Cross section of con- EAN code ductor and colour (SSTL code) 64 100+ MK 1,5 RU 04 021 02-6 MK 1,5 MU 04 021 03-3 MK 1,5 SI 04 021 07-1 MK 1,5 KEVI 04 021 08-8 MK 2,5 RU 04 021 22-4 MK 2,5 MU 04 021 23-1 MK 2,5 SI 04 021 27-9 MK 2,5 KEVI 04 021 28-6 MK 4 MU 04 021 43-9 MK 4 SI 04 021 47-7 MK 4 KEVI 04 021 48-4 PK 6 MU 04 024 63-8 PK 6 SI 04 024 67-6 PK 6 KORO 04 024 69-0 PK 10 MU 04 024 73-7 PK 10 SI 04 024 77-5 PK 10 KORO 04 024 79-9 PK 16 MU 04 024 83-6 PK 16 SI 04 024 87-4 PK 16 KORO 04 024 89-8 PK 25 MU 04 024 91-1 PK 25 SI 04 024 96-3 PK 25 KORO 04 024 98-0 MK 35 MU 04 522 22-6 MK 35 SI 04 522 23-3 MK 35 KEVI 04 522 27-1 MK 50 MU 04 522 33-2 MK 50 SI 04 522 37-0 MK 50 KEVI 04 522 38-7 MK 70 KEVI 04 022 48-6 MK 95 KEVI 04 022 58-0 120 KEVI 04 022 66-5 54 | Draka Keila Cables Nominal overall diameter mm 3 3 3 3 3,7 3,7 3,7 3,7 4,2 4,2 4,2 4,8 4,8 4,8 6,1 6,1 6,1 7,2 7,2 7,2 8,9 8,9 8,9 10 10 10 11,7 11,7 11,7 13,4 16 18 Total weight kg/km 22 22 22 22 35 35 35 35 52 52 52 70 70 70 115 115 115 175 175 175 270 270 270 370 370 370 510 510 510 710 1000 1200 Direct current resistance of conductor at 20˚C max. Ω/km 12,1 12,1 12,1 12,1 7,41 7,41 7,41 7,41 4,61 4,61 4,61 3,08 3,08 3,08 1,83 1,83 1,83 1,15 1,15 1,15 0,727 0,727 0,727 0,524 0,524 0,524 0,387 0,387 0.387 0.268 0.193 0.153 Standard delivery Standard delivery length, coil length, drum m 250 250 250 250 200 200 200 200 150 150 150 100 100 100 100 100 100 100 100 100 100 100 100 500/6C 500/6C 500/6C 200/6C 200/6C 200/6C 200/6C 500/8E 800/11G Product Catalogue Installation cables and wires MK 90 / H07V2-R PVC-insulated stranded conductor Application Temperature range For permanent installation in a conduit, and for wiring in appliances, switchgear and control gear with a maximum voltage of 1000 V (AC) or a maximum of 750 V (DC) to earth. Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C – in a short circuit (max.5 s) . . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . -25˚C Standards Bending radius SFS 5523, CENELEC HD 21, IEC 60332-14 During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D In a final installation if bent only once min.. . . . . . . . . . 3D Certificate/approval Construction FI, <HAR> Conductor . . . . . . . annealed copper wires, stranded Insulation . . . . . . . . lead-free Linyl PVC, core identification by colours Rated voltage U0/U = 450/750 V Identification of cores RU, PRU – brown, MU – black, KEVI – yellow-green, SI – blue Cross section of con- EAN code ductor and colour (SSTL code) 64 100+ MK 1,5 RU 04 01704-3 MK 1,5 MU 04 01703-6 MK 1,5 SI 04 01705-0 MK 1,5 KEVI 04 01702-9 MK 2,5 RU 04 01708-1 MK 2,5 MU 04 01707-4 MK 2,5 SI 04 01709-8 MK 2,5 KEVI 04 01706-7 MK 4 MU 04 01711-91 MK 4 SI 04 01713-5 MK 4 KEVI 04 01710-4 PK 6 RU 04 01716-6 PK 6 MU 04 01715-9 PK 6 SI 04 01717-3 PK 6 KEVI 04 01714-2 PK 10 MU 04 01719-5 PK 10 SI 04 01720-3 PK 10 KEVI 04 01718-0 PK 16 MU 04 01722-7 PK 16 SI 04 01723-4 PK 16 KEVI 04 01721-0 PK 25 SI 04 02215-3 PK 25 KEVI 04 02216-0 MK 35 MU 04 52222-6 MK 35 SI 04 52223-3 MK 35 KEVI 04 52227-1 MK 50 MU 04 52233-2 MK 50 SI 04 52237-0 MK 50 KEVI 04 52238-7 MK 70 KEVI 04 022 48-6 MK 95 KEVI 04 022 58-0 120 KEVI 04 022 66-5 Product Catalogue Nominal overall diameter mm 3 3 3 3 3,7 3,7 3,7 3,7 4,2 4,2 4,2 4,8 4,8 4,8 4,8 6,1 6,1 6,1 7,2 7,2 7,2 8,9 8,9 10 10 10 11,7 11,7 11,7 13,4 16 18 Total weight kg/km 22 22 22 22 35 35 35 35 52 52 52 70 70 70 70 115 115 115 175 175 175 270 270 370 370 370 510 510 510 710 1000 1200 Direct current resistance of conductor at 20˚C max. Ω/km 12,1 12,1 12,1 12,1 7,41 7,41 7,41 7,41 4,61 4,61 4,61 3,08 3,08 3,08 3,08 1,83 1,83 1,83 1,15 1,15 1,15 0,727 0,727 0,524 0,524 0,524 0,387 0,387 0,387 0,268 0,193 0,153 Standard delivery Standard delivery length, coil length, drum m 250 250 250 250 200 200 200 200 150 150 150 100 100 100 100 100 100 100 100 100 100 100 100 500/6C 500/6C 500/6C 200/6C 200/6C 200/6C 200/6C 500/8E 800/11G Draka Keila Cables | 55 Installation cables and wires MKEM 90 / H07V2-K PVC-insulated flexible conductor Application Construction For fixed installation in a conduit, and for wiring in appliances, switchgear and control gear with a maximum voltage of 1000 V (AC) or a maximum of 750 V (DC) to earth. Conductor . . . . annealed copper wires, stranded flexible Insulation . . . . . lead-free Linyl PVC, core identification by colours Temperature range Identification of cores Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C – in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . -25˚C RU – brown, MU – black, KEVI – yellow-green, SI – blue Bending radius Certificate/approval During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . 8D In a final installation if bent only once min. . . . . . . . . . 3D FI, <HAR> Standards SFS 5523, CENELEC HD 21, IEC 60332-14 Rated voltage U0/U = 450/750 V Cross section of con- EAN code (SSTL ductor and colour code) 64 100+ 1,5 RU 04 03102-5 1,5 MU 04 03103-2 1,5 SI 04 03107-0 1,5 KEVI 04 03108-7 2,5 RU 04 03122-3 2,5 MU 04 03123-0 2,5 SI 04 03127-8 2,5 KEVI 04 03128-5 4 MU 04 03143-8 4 SI 04 03147-6 4 KEVI 04 03148-3 6 MU 04 03163-6 6 SI 04 03167-4 6 KEVI 04 03168-1 10 MU 04 03183-4 10 SI 04 03187-2 10 KEVI 04 03188-9 16 MU 04 03203-9 16 SI 04 03207-9 16 KEVI 04 03208-9 25 MU 04 03213-8 25 SI 04 03217-6 25 KEVI 04 03218-3 35 MU 04 53223-2 35 SI 04 53227-0 35 KEVI 04 53228-7 50 MU 04 53233-1 50 SI 04 53237-9 50 KEVI 04 53238-6 70 MU 04 022 43-0 70 SI 04 022 47-8 70 KEVI 04 022 48-5 95 MU 04 03253-4 95 SI 04 03257-2 120 MU 04 032 63-3 150 MU 04 032 73-2 56 | Draka Keila Cables Nominal overall diameter mm 3 3 3 3 3,6 3,6 3,6 3,6 4,1 4,1 4,1 5 5 5 6,5 6,5 6,5 7,6 7,6 7,6 9,4 9,4 9,4 11 11 11 13 13 13 15 15 15 17,5 17,5 19 22 Total weight Direct current resistance of conductor at 20˚C max. kg/km Ω/km 21 13,3 21 13,3 21 13,3 21 13,3 32 7,98 32 7,98 32 7,98 32 7,98 45 4,95 45 4,95 45 4,95 70 3,3 70 3,3 70 3,3 115 1,91 115 1,91 115 1,91 170 1,21 170 1,21 170 1,21 270 0,78 270 0,78 270 0,78 370 0,554 370 0,554 370 0,554 520 0,386 520 0,386 520 0,386 730 0,272 730 0,272 730 0,272 940 0,206 940 0,206 1200 0,161 1450 0,129 Standard delivery Standard delivery length, coil length, drum m m 250 250 250 250 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 500/6C 500/6C 500/6C 200/6C 200/6C 200/6C 200/6C 200/6C 200/6C 200/7E 200/7E 200/7E 200/7E Product Catalogue Installation cables and wires MMO PVC sheated control cable Application Standards Cables for control, measuring and signal circuits of electrical equipment. EVS 722:1996, SFS 3714; HD 627 Fixed surface or flush-mounted installations, indoors and outdoors. Direct sunlight may change the colour of the sheath. EEI, FI Rated voltage U0/U=450/750 V Temperature range Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . –15˚C Construction Conductor . . . . . . . annealed copper wires Insulation . . . . . . . . black PVC, core identification by numbers Sheath . . . . . . . . . . white PVC, marked by meters Number of conductors and cross section n x mm2 7x1,5 12x1,5 19x1,5 27x1,5 37x1,5 7x2,5 12x2,5 19x2,5 Certificate/approval EAN code (SSTL code) 64 100+ 04 112 03-8 04 112 05-2 04 112 07-6 04 120 25-5 04 120 26-2 04 112 13-7 04 112 15-1 04 112 17-5 Nominal overall diameter mm 12 15 18 21 24 14 18 21 Bending radius During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . 10D In a final installation if bent only once min.. . . . . . . . . . 3D Identification of cores Core identification by numbers. Total weight kg/km 230 350 500 700 950 310 500 750 Direct current resistance of conductor at 20˚C max. Ω/km 12,1 12,1 12,1 12,1 12,1 7,41 7,41 7,41 Standard delivery length, drum m 1000/K8 500/K8 500/K9 500/K11 500/K11 500/K8 500/K8 500/K11 Nominal values unless otherwise specified. Product Catalogue Draka Keila Cables | 57 Installation cables and wires EKLK 450/750 V Installation cable Application fields Temperature range Fixed installation, indoors and outdoors, in pipes, ducts, in or under plaster, also suspended in catenary system. In ground, only if the cable is protected against mechanical damage. In continuous operation max. conductor temp . . . . . 70˚C Lowest cable temperature under installation . . . . . .-15˚C and below 0˚C special precaution shall be taken. Alternative designation Bending radius 12D (6D in final installation, bent only once) SE-N07VA5EV-U Design Standard Halogen-free alternative Conductor . . . . . . . solid and annealed copper acc. to IEC 60228 class 1 Insulation . . . . . . . . lead-free PVC Filler . . . . . . . . . . . . lead-free PVC Concentric conductor . aluminium with bonded PVC in contact with drain wire of tinned copper Inner sheath . . . . . PE, white Sheath . . . . . . . . . . lead-free PVC, white, meter marked EQLQ Identification of cores Approval Material declaration 2-core . . . . . . . . . . . blue, brown 3-core . . . . . . . . . . . green/yellow, blue, brown 4-core . . . . . . . . . . . . green/yellow, blue, brown, black 5-core . . . . . . . . . . . green/yellow, blue, brown, black, grey EKLK Marking SS 424 02 19-4 Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN 50265-2-1 SEMKO, CE E.g. EKLK 3G1,5 S BLYFRI F3 DRAKA SE. Number of cores x cross section of conductor mm2 Without earth conductor 2x1,5 2x1,5 With earth conductor 3G1,5 3G1,5 3G1,5 3G1,5 3G2,5 3G2,5 3G2,5 3G2,5 4G1,5 4G1,5 4G1,5 4G2,5 4G2,5 5G1,5 5G1,5 5G1,5 5G1,5 5G2,5 5G2,5 5G2,5 5G2,5 58 | Draka Keila Cables Overall diameter (approx.) mm Weight (approx.) Standard delivery length m Standard drum size/Package Article number 10 10 14,3 14,3 50 500 Ring K6 423101 423105 9,8 9,8 9,8 9,8 11,6 11,6 11,6 11,6 10,8 10,8 10,8 13,1 13,1 11,8 11,8 11,8 11,8 13,9 13,9 13,9 13,9 14 14 14 14 21,3 21,3 21,3 21,3 19 19 19 25,7 25,7 22,5 22,5 22,5 22,5 30,9 30,9 30,9 30,9 50 250 500 1000 50 150 500 1000 50 200 500 50 500 50 150 500 1000 50 150 500 1000 Ring K4 K6 K7 Ring K4 K6 K8 Ring K4 K6 Ring K7 Ring K4 K7 K9 Ring K4 K7 K9 423001 423003 423005 423006 423011 423013 423015 423016 423021 423023 423025 423031 423035 423041 423043 423045 423046 423051 423053 423055 423056 kg/100 m Product Catalogue Installation cables and wires PPJ PVC sheathed installation cable Application Bending radius For fixed surface or flush-mounted installations, indoors and outdoors. Suitable for installation in a slot covered with plaster. Not for installation directly in ground or directly in concrete without protective ducting. Cable needs protection from direct sunlight. Recommended during installation min. . . . . . . . . . . . . 10D In a final installation if bent only once min . . . . . . . . . . 3D Standards Conductor . . . . . . . annealed copper wires; 1,5 – 4 mm2 solid and 6 – 25 mm2 stranded Insulation . . . . . . . . PVC, core identification by colours Filling . . . . . . . . . . . filling compound Sheath . . . . . . . . . . white PVC, marked by meters EVS 720:1996, EVS 721:1996, SFS 2091, SFS 5524 Identification of cores Certificate/approval Core identification according to the HD 308 S2:2002 EEI, FI, CE X type without green/yellow core Rated voltage 2-core . . . . . . . . . . . . . . . . blue, brown 3-core . . . . . . . . . . . . . . . . brown, black, grey Max. permissible tensile stress during installation . . . . . . . . . . . . . . . . . . . . . .Ax50 N/mm2 U0/U=300/500 V (1,5–4 mm2), U0/U=450/750 V (6–25 mm2) Temperature range Highest permissible conductor temperature – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C Lowest recommended handling temperature . . . . . –15˚C Number of EAN code conductors and (SSTL code) cross section reel 64 100+ n x mm2 Without protective conductor 2x1,5 04 073 12-4 3x1,5 04 073 22-3 2x2,5 04 073 13-1 With protective conductor 3G1,5 04 072 22-6 4G1,5 04 072 32-5 5G1,5 04 072 42-4 3G2,5 04 072 23-3 4G2,5 04 072 33-2 5G2,5 04 072 43-1 3G4 4G4 5G4 3G6 4G6 5G6 4G10 5G10 4G16 5G16 4G25 5G25 Product Catalogue Construction EAN code (SSTL code) drum 04 572 22-1 04 572 32-0 04 072 42-9 04 572 23-8 04 572 33-7 04 572 43-6 04 572 24-5 04 572 34-4 04 572 44-3 04 572 25-2 04 572 35-1 04 572 45-0 04 572 36-8 04 572 46-7 04 572 37-5 04 572 47-4 04 572 38-2 04 572 48-1 Nominal overall diameter mm G type with green/yellow core 3-core . . . . . . . . . . . . . . . . green/yellow, blue, brown 4-core (1,5 and 2,5 mm2) . green/yellow, blue, brown,black 4-core (4–25 mm2). . . . . . . green/yellow, brown, black, grey 5-core . . . . . . . . . . . . . . . . green/yellow, blue, brown, black, grey Total weight kg/km Direct current resistance of conductor at 20˚C max Ω/km Standard delivery length, reel m 8 9 10 105 125 150 12,1 12,1 7,41 100 100 100 9 10 10 10 11 12 10 12 13 14 16 17 19 21 22 24 30 31 125 155 180 180 220 260 280 340 410 350 430 510 670 810 950 1150 1780 1900 12,1 12,1 12,1 7,41 7,41 7,41 4,61 4,61 4,61 3,08 3,08 3,08 1,83 1,83 1,15 1,15 0,727 0,727 100 100 50 100 50 50 Standard delivery length, drum m 2000 1000 1000 1000 1000 750 1000 750 500 500 500 500 400 250 250 250 250 250 Draka Keila Cables | 59 Installation cables and wires MSK / H05VV-F Flexible cord Application Bending radius Cord for ordinary duty use for portable appliances in domestic premises, kitchens and offices. - For household appliances in dry and damp premises. - Not for outdoor use, industrial use, agricultural use. Min. recommended bending radius in normal usage. . . 6D Construction Conductor��������������Annealed copper wires, stranded, flexible Insulation����������������PVC, core identification by colours Sheath��������������������PVC, round The weight of a lighting fixture hanging from the cable must not exceed 2 kg. Standard Identification of cores SFS 5525 = CENELEC HD 21 N type without green/yellow core. . . . . . . . . . . . . . . 2-core S type with green/yellow core. . . . . . . . . . . . . . . . . BU – BN 3-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GNYE – BU – BN 4-core. . . . . . . . . . . . . . . . . . . . . . . . . . GNYE – BK – BU – BN 5-core. . . . . . . . . . . . . . . . . . . . . . GNYE – BK – BU – BN – BK Certificate/approval FI (FIMKO), CE, <HAR> Rated voltage U0/U = 300/500 V Temperature range Maximum permissible temperature of conductor: – in continuous use . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60˚C - in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 150˚C Lowest recommended handling temperature. . . . . . . 15˚C Number of conductors and EAN code (SSTL cross section code) 64 100+ With protective conductor 3 x 0,75 S 04 197 20-2 3 x 1,0 S 04 197 21-9 3 x 1,5 S white 04 197 22-6 3 x 1,5 S grey 04 198 22-3 4 x 0,75 S 04 197 30-1 4 x 1,5 S 04 197 32-5 5 x 1,0 S 04 197 41-7 5 x 1,5 S 04 197 42-4 Without protective conductor 2 x 0,75 N 04 194 10-2 2 x 1,0 N 04 194 11-9 2 x 1,5 N 04 194 12-6 Nominal overall Total weight diameter mm kg/km Direct current resistance of Standard delivery conductor at +20˚C max. length coil Ω/km m 6,6 7 8,3 8,3 7,2 9,3 8,6 10,3 65 72 100 100 75 130 110 160 26 19,5 13,3 13,3 26 13,3 19,5 13,3 100 100 100 100 100 100 100 100 6,2 6,6 7,6 52 60 80 26 19,5 13,3 100 100 100 Abbreviations of colours VA = WH White HA = GY Grey 60 | Draka Keila Cables Product Catalogue Installation cables and wires PROFIT Conduit with cores Application Properties of cables and cores as without conduit. For fixed installation in electrical- and information network. Conduit is suitable for installation in concrete Current carrying capacities of ML/MK/MKZ according to HD 384.5.523 (or IEC 364-5-523): “Electrical installation of buildings” section 523: Current carrying capacities. Standards Conduit EN 50086, cables and wires have own Conduit. . . . . . . . . . Flexible PP conduit, lead-free, ICTA 3342 Certificates CE, RoHS Properties Self-extinguishing Maximum permissible temperature of conduit in use and installation . . . . . . . . . . . . . . . . . . . . . . . . . .90˚C Minimum permissible temperature of conduit in installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –25˚C Compression resistance . . . . . . . . . . . . . . . 750 N (ICTA 3) Impact resistance . . . . . . . . . . . . . . . 2 kg/100 mm (ICTA 3) Convenient installation without twists Multi-installation base ensure uncoiled and smooth running of the cable from the package. SSTL code 64 070 09 Product Catalogue Construction Cables and cores PROFIT ML. . . . . . . H07V-U cores in Ø16/20 conduit PROFIT MK . . . . . . H07V-R cores in Ø16/20 conduit PROFIT MKZ . . . . . H07V-R cores in Ø16/20 conduit, wires twisted together PROFIT CAT 5e . . . CAT 5e UTP in Ø20 conduit PROFIT CAT 6 . . . . CAT 6 UTP in Ø20 conduit PROFIT TELLU 13 . . TELLU 13 in Ø16 conduit PROFIT MHS . . . . . MHS in Ø16 conduit ML(H07V-U), MK(H07V-R), MKZ colours according to HD 308 S2 Name SSTL code PROFIT MK 3x1.5 S 16/R100 PROFIT MK 3x2.5 S 16/R100 PROFIT MK 3x4 S 20/R50 PROFIT MK 4x1.5 S 16/R100 PROFIT MK 4x2.5 S 20/R50 PROFIT MK 5x1.5 S 20/R50 PROFIT MK 5x2.5 S 20/R50 PROFIT MK 6 KEVI 16/R100 PROFIT MK 7x1.5 S 20/R50 PROFIT ML 3x1.5 N 16/R100 PROFIT ML 3x1.5 S 16/R100 PROFIT ML 3x2.5 S 16/R100 PROFIT ML 4x1.5 S 16/R100 PROFIT ML 5x1.5 N 16/R100 PROFIT ML 5x1.5 S 16/R100 PROFIT ML 5x2.5 S 20/R100 PROFIT ML 7x1.5 S 20/R100 PROFIT CAT 5e UTP 2x4p 20/R100 PROFIT CAT 6 UTP 2x4p 20/R100 PROFIT TELLU 13 16/R100 PROFIT MHS 3x2x0,5 16/R100 04 123 02 04 123 04 04 017 34 04 123 06 04 017 42 04 123 08 04 123 10 04 123 12 04 011 30 04 011 32 04 011 34 04 011 36 04 011 38 04 011 40 04 011 41 04 017 71 02 413 12 02 413 14 02 321 78 02 024 07 Total weight kg/km 110 145 210 130 190 165 225 115 205 105 105 140 125 160 160 215 195 130 140 105 85 Coil length m Pallet length m 100 100 50 100 50 50 50 100 50 100 100 100 100 100 100 100 100 100 100 100 100 1800 1800 900 1800 900 900 900 1800 900 1800 1800 1800 1800 900 900 900 900 900 900 1800 1800 Draka Keila Cables | 61 Automation, data and telecommunication cables JAMAK Instrumentation cable Applications Identification • Fixed indoor installations • Automation • Instrumentation • Process control • Audio systems • Suitable for MaxiTermipoint connections Units marked with numbers, a-conductors are blue and b-conductors are red. Construction Conductor . . . . . . . stranded tinned copper Insulation . . . . . . . . PE Unit . . . . . . . . . . . . . twisted and individually with, plasticaluminium tape shielded pair, earth conductor and a number tape Shield . . . . . . . . . . . plastic aluminium tape with earth conductor Sheath . . . . . . . . . . grey Linyl PVC Number and size of the conductor EAN code (SSTL code) Nominal diameter Mass Delivery length Drum Electrical properties 20˚C Maximum loop resistance Nominal mutual capacitance (800 Hz) Impedance, 10 MHz Minimum insulation resistance Velocity factor Maximum voltage Nominal attenuation frequency 9,6 kHz frequency 19,2 kHz frequency 64 kHz frequency 100 kHz frequency 200 kHz frequency 1,0 MHz Other properties Bending radius during installation, min. (D=outer diameter) during operation, min. Installation temperature min. Max operation temperature 62 | Draka Keila Cables mm2 64 100+ mm kg/km m Ω/km µF/km Ω GΩ x km V dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m mm mm ˚C ˚C 2 x(2+1)x 0,5 02 642 52-0 8 70 1000 K6 4 x(2+1)x 0,5 02 642 54-4 9,5 110 1000 K7 8 x(2+1)x 0,5 02 642 58-2 13 200 1000 K9 12 x(2+1)x 0,5 02 642 62-9 15 280 1000 K10 24 x(2+1)x 0,5 02 642 64-3 21 530 1000 K12 48 x(2+1)x 0,5 02 642 68-1 29 990 500 K12 81 85 70 ± 10 % 2 0,66 75 0,3 0,5 0,7 0,9 1,6 4,5 15D 10D –5 70 Product Catalogue Automation, data and telecommunication cables JAMAK ARM Instrumentation cable Applications Construction • Fixed outdoor installations • Automation • Instrumentation • Process control • Audio systems • Suitable for MaxiTermipoint connections Conductor . . . . . . . stranded tinned copper Insulation . . . . . . . . PE Unit . . . . . . . . . . . . . twisted and individually with plasticaluminium tape shielded pair, earth conductor and a number tape Shield . . . . . . . . . . . plastic/aluminium tape with earth conductor Sheath . . . . . . . . . . grey Linyl PVC Armouring . . . . . . . wrapped steel band Outer sheath . . . . black PE Suitable specially for digital and low level analog signal transmission. The construction gives an excellent protection against electromagnetic interference. Identification Units marked with number tape, a-conductors are blue and b-conductors are red. Other properties JAMAK ARM is also available as halogen-free (JAMAK ARM-HF) Number and size of the conductor EAN code (SSTL code) Nominal diameter Mass Delivery length Drum Electrical properties 20˚C Maximum loop resistance Nominal mutual capacitance (800 Hz) Impedance, 10 MHz Minimum insulation resistance Velocity factor Maximum voltage Nominal attenuation frequency 9,6 kHz frequency 19,2 kHz frequency 64 kHz frequency 100 kHz frequency 200 kHz frequency 1,0 MHz Other properties during installation, min. Bending radius (D=outer diameter) during operation, min. Installation temperature min. Max operation temperature Product Catalogue mm2 64 100+ mm kg/km m Ω/km µF/km Ω GΩ x km V dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m mm mm ˚C ˚C 4 x (2+1) x 0,5 02 642 72-4 14 240 1000 K9 8 x (2+1) x 0,5 02 642 78-0 17 370 1000 K11 12 x (2+1) x 0,5 02 642 82-7 19 480 1000 K11 24 x (2+1) x 0,5 02 642 84-1 25 820 1000 K14 48 x (2+1) x 0,5 02 642 88-9 33 1440 500 K18 81 85 70 ± 10 % 2 0,66 75 0,3 0,5 0,7 0,9 1,6 4,5 15D 10D -5 70 Draka Keila Cables | 63 Automation, data and telecommunication cables NOMAK Instrumentation cable Application Identification • Fixed indoor installations • Automation • Instrumentation • Process control • Suitable for Maxi Termipoint connections Pairs marked with numbers, a-conductors are orange and b-conductors are white. Construction Conductor . . . . . . . stranded tinned copper Insulation . . . . . . . PVC Unit . . . . . . . . . . . . twisted pair Overall shield . . . . plastic/aluminium tape with earth conductor Sheath . . . . . . . . . . grey Linyl PVC Number and size of the conductor EAN code (SSTL code) Nominal diameter Mass Delivery length Drum Electrical properties 20˚C Maximum loop resistance Nominal mutual capacitance (800 Hz) Impedance, 10 MHz Minimum insulation resistance Velocity factor Maximum voltage Nominal attenuation frequency 9,6 kHz frequency 19,2 kHz frequency 64 kHz frequency 100 kHz frequency 200 kHz frequency 1,0 MHz Other properties Bending radius during installation, min. (D – outer diameter) during operation, min. Installation temperature min. Max operation temperature 64 | Draka Keila Cables n x n mm2 64 100+ mm kg/km m 2 x 2 x 0,5 02 649 52-9 7,5 55 1000 K6 4 x 2 x 0,5 02 649 54-3 9 85 1000 K6 8 x 2 x 0,5 02 649 58-1 12 150 1000 K7 Ω/km µF/km Ω 81 90 81 90 81 85 GΩ x km V dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m mm mm ˚C ˚C 12 x 2 x 0,5 02 649 62-8 13 210 1000 K9 81 85 100 ± 10 % 100 0,6 75 0,3 0,5 0,7 0,9 1,5 2,9 24 x 2 x 0,5 02 649 64-2 18 400 1000 K11 48 x 2 x 0,5 02 649 68-0 24 720 1000 K14 81 85 81 85 15D 10D -5 70 Product Catalogue Automation, data and telecommunication cables KLMA Signal cable Applications Identification • Fixed indoor installations • Building automation • Alarm, signal and security control transmission 1. conductor . . . . . . . . . . 2. conductor . . . . . . . . . 3. conductor . . . . . . . . . 4. conductor . . . . . . . . . Construction According to . . Conductor . . . . Insulation . . . . . Unit . . . . . . . . . SFS 2755 tinned copper PVC twisted conductors shielded with plastic/aluminium tape,earth conductor Sheath . . . . . . . grey Linyl PVC Number and size of the conductor EAN code (SSTL code) Nominal diameter Mass Delivery length Electrical properties 20˚C Maximum loop resistance Minimum insulation resistance Maximum voltage Other properties Bending radius (D=outer diameter) Installation temperature min. Max operation temperature Product Catalogue blue yellow white red Other properties KLMA is also available as halogen-free KLMA-LSZH version n x mm 64 100+ mm kg/km m 2 x 0,8 + 0,8 02 920 01-7 5 30 500 4 x 0,8 + 0,8 02 920 03-1 5,5 45 500 Ω/km GΩ x km V 36,7 500 75 36,7 500 75 15D 10D –5 70 15D 10D –5 70 during installation, min. mm during operation, min. mm ˚C ˚C Draka Keila Cables | 65 Automation, data and telecommunication cables PULS 2,5 75V Traffic sensor cable Application Temperature range Traffic light cable with a maximum voltage of 75 V (AC) or a maximum of 50 V (DC) to earth. Highest permissible conductor temperature - in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C - in a short circuit (max. 30 s) . . . . . . . . . . . . . . . . . 200˚C Lowest recommended handling temperature . . . . . –40˚C Standards IEC 60228, CENELEC HD 22, IEC 60332-1 Certificate/approval RoHS Rated voltage Construction Conductor . . . . . . . annealed tinned copper wires, stranded flexible Insulation . . . . . . . . heat resistant plastic Outer sheath . . . . . black oil retardant rubber U = 75 VDC; 50 VAC Bending radius During installation . . . . . . . . . . . . . . . . . . . . . . . . . . . min 3D Cross section of conductor and colour EAN code (SSTL code) Nominal overall diameter Total weight Direct current resistance of conductor at 20˚C max. Minimum recommended bending radius during installation Standard delivery length Reel 66 | Draka Keila Cables 64 100+ mm kg/km Ω/km m m PULS 2,5 MU 75 V 0231002 4 30 8,21 0,012 1000 S4 Product Catalogue Automation, data and telecommunication cables MHS Indoor telecommunication cable Construction Conductor . . . . . . . annealed, tinned copper wire Insulation . . . . . . . . PE Twinning. . . . . . . . . two insulated conductors in a pair Lay-up . . . . . . . . . . stranded into units Signal wire . . . . . . . red, insulated conductor Ground wire . . . . . . annealed, tinned copper wire Screen . . . . . . . . . . plastic coated aluminium foil Sheath . . . . . . . . . . grey Linyl PVC Electric properties (+20˚C) Loop resistance maximum maximum average Insulation resistance minimum 500 V, 1 min. Mutual capacitance maximum maximum average Capacitance unbalance maximum over 30-pair cables, 95 % of values Conductor number and diameter mm 1 x 4 x 0,5 drum coil coil 3 x 2 x 0,5 drum coil 5 x 2 x 0,5 drum coil 10 x 2 x 0,5 drum coil 20 x 2 x 0,5 drum coil 30 x 2 x 0,5 50 x 2 x 0,5 100 x 2 x 0,5 200 x 2 x 0,5 400 x 2 x 0,5 800 x 2 x 0,5 Product Catalogue EAN code Nominal sheath thickness 64 100+ mm 1,0 192 Ω/km 184 Ω/km 500 MΩkm 65 µF/km 60 µF/km 250 pF/500 m 150 pF/500 m Nominal outer diameter mm 4,5 Nominal mass kg/km 30 02 951 31-8 02 551 21-1 02 551 31-0 1000 100 300 1,0 5,0 36 02 951 32-5 02 551 32-7 1000 200 1,0 6,0 50 02 951 33-2 02 551 33-4 1000 150 1,0 7,6 78 02 551 34-1 02 551 35-8 02 551 36-5 02 551 39-6 02 551 37-2 02 551 38-9 02 551 40-2 02 551 42-6 02 551 44-0 02 551 48-8 Standard delivery length m 1000 200 1,0 9,5 130 1,1 1,1 1,2 1,5 1,8 2,2 11,5 14,0 19,0 26,0 36,0 50,0 185 285 550 1030 2000 3950 1000 150 1000 1000 1000 1000 500 500 Draka Keila Cables | 67 Automation, data and telecommunication cables VMOHBU Outdoor telecommunication cable Construction Conductor . . . . . . . annealed copper wire Insulation . . . . . . . . PE Twinning. . . . . . . . . two insulated conductors in a pair Signal wire . . . . . . . red, insulated conductor Filling compound. . special jelly Screen . . . . . . . . . . aluminium laminate Sheath . . . . . . . . . . black PE Electric properties (+20˚C) Number of pairs in cable Mutual capacitance maximum Mutual capacitance max average µF/km µF/km Diameter of conductor Resistance unbalance maximum mm % 0,8 Diameter of conductor Loop resistance max Loop resistance max average mm Ω/km Ω/km 0,4 300 288 Insulation resistance 500 V, 1 min Minimum GΩ km 2 Diameter of Capacitance unbalance conductor pair-to pair maximum 95% of values pF/500 m pF/500 m mm 0,4-0,6 250 150 0,8 180 100 68 | Draka Keila Cables 50 and more less than 50 45 46 40 – 2 0,5 192 184 0,6 134 128 0,8 74 71 Capacitance unbalance pair-to-earth maximum 95% of value pF/500 m pF/500 m 1700 1000 Conductor number and diameter mm 100 x 2 x 0,4 200 x 2 x 0,4 300 x 2 x 0,4 400 x 2 x 0,4 600 x 2 x 0,4 800 x 2 x 0,4 1200 x 2 x 0,4 3 x 2 x 0,5 5 x 2 x 0,5 10 x 2 x 0,5 20 x 2 x 0,5 30 x 2 x 0,5 50 x 2 x 0,5 100 x 2 x 0,5 200 x 2 x 0,5 300 x 2 x 0,5 400 x 2 x 0,5 600 x 2 x 0,5 800 x 2 x 0,5 5 x 2 x 0,6 10 x 2 x 0,6 20 x 2 x 0,6 30 x 2 x 0,6 50 x 2 x 0,6 100 x 2 x 0,6 200 x 2 x 0,6 300 x 2 x 0,6 400 x 2 x 0,6 10 x 2 x 0,8 20 x 2 x 0,8 30 x 2 x 0,8 50 x 2 x 0,8 100 x 2 x 0,8 3 x 2 x 1,0 EAN code 64 100+ 02 565 08-9 02 565 09-6 02 565 11-9 02 565 12-6 02 565 13-3 02 565 14-0 02 565 16-4 02 563 21-4 02 564 74-7 02 564 75-4 02 564 76-1 02 564 77-8 02 564 78-5 02 564 79-2 02 564 80-8 02 564 81-5 02 564 82-2 02 564 83-9 02 564 84-6 02 565 43-0 02 565 44-7 02 565 45-4 02 565 46-1 02 565 47-8 02 565 48-5 02 565 62-1 02 565 63-8 02 565 64-5 02 565 50-8 02 565 51-5 02 565 52-2 02 565 53-9 02 565 54-6 02 565 03-4 Nominal sheath thickness mm 2,2 2,4 2,6 2,6 2,8 3 3 2 2 2 2 2 2 2,2 2,4 2,4 2,6 3 3,2 2 2 2 2 2 2,2 2,6 2,6 2,6 2 2 2 2,2 2,4 2 Nominal outer diameter mm 24 33 38 43 52 58 71 9,7 11 12,5 15,5 17,5 22 28 39 45 52 62 71 12 14 17,5 21 25 33 46 54 63 16,5 22 25 32 42 14 Nominal cable mass kg/km 600 1150 1600 2100 3000 3850 5700 80 105 145 235 315 480 860 1650 2350 3050 4500 5900 130 185 305 425 630 1200 2300 3300 4400 275 480 680 1100 2000 185 Standard delivery length m 1000 1000 1000 1000 500 500 500 1000 1000 1000 1000 1000 1000 1000 1000 1000 500 500 500 1000 1000 1000 1000 1000 1000 1000 500 500 1000 1000 1000 1000 1000 1000 Product Catalogue Automation, data and telecommunication cables H05RN-F; RDO/05RN-F 300/500 V Rubber cable Application fields Bending radius A highly flexible weather resistant cable, for the connection of light portable equipment where the risk of mechanical stress is low. Suitable for permanent outdoor use. During installation . . . . . . . . . . . . . . . . . . . . . . . . . . . min 6D Standard SS 424 02 35, CENELEC HD 22.4 Design Conductor. . Flexible and annealed copper acc. to IEC 60228 class 5 Insulation . . EPDM-rubber H05-, H07RN-F, RDO/05RN-F Core identification 2-core . . . . . blue, brown 3-core . . . . . green/yellow, blue, brown 4-core . . . . . green/yellow, brown, black, grey 5-core . . . . . green/yellow, blue, brown, black, grey 7-core . . . . . green/yellow, 6 cores black number-marked 1-6 Sheath . . . . weather and oil resistant Bjuroflex rubber Approval Marking H05RN-F . . . . . . . . <HAR>, C RDO/05RN-F . . . . . SEMKO, C E.g. DRAKAFLEX SEMKO <HAR> H05RN-F 2X1. Fire propagation class F2 acc. to SS 424 14 75 and IEC 60332-1 Material declaration Temperature range In continuous operation max. conductor temp . . . . .60˚C The cable is flexible down to . . . . . . . . . . . . . . . . . . . –25˚C Number of cores x cross section of conductor mm2 H05RN-F 2x0,75 2x0,75 2x1 2x1 3G0,75 3G0,75 3G1 3G1 RDO/05RN-F 2x1,5 2x1,5 3G1,5 3G1,5 3G2,5 3G2,5 4G1,5 4G1,5 4G2,5 4G2,5 5G1,5 5G1,5 5G2,5 5G2,5 7G1,5 Product Catalogue Overall diameter (approx.) mm Weight (approx.) kg/100 m Standard delivery length m Standard drum size/package Article number 6,3 6,3 6,9 6,9 6,9 6,9 7,3 7,3 6 6 7,1 7,1 7,7 7,7 8,8 8,8 100 500 100 500 100 500 100 500 Coil K6 Coil K6 Coil K6 Coil K6 952002040202 952002040205 952002070202 952002070205 952003040202 952003040205 952003070202 952003070205 8,3 8,3 9 9 10,5 10,5 9 9 11,8 11,8 11,2 11,2 13 13 12,6 10,4 10,4 12,1 12,1 17 17 15,1 15,1 21,2 21,2 18,3 18,3 26,1 26,1 24,1 100 500 100 500 50 500 50 500 50 500 50 500 50 500 500 Coil K6 Coil K6 Coil K6 Coil K6 Coil K7 Coil K6 Coil K7 K7 952002080202 952002080205 952003080202 952003080205 952003100201 952003100205 952004080201 952004080205 952004100201 952004100205 952005080201 952005080205 952005100201 952005100205 952007080205 Draka Keila Cables | 69 Automation, data and telecommunication cables DRAKAFLEX H07RN-F 450/750 V Rubber cable Application fields Bending radius A highly flexible weather and oil resistant cable. For use where the mechanical stress have medium hard character, in spaces with explosion risks or dry and damp spaces. Outdoors e.g. in agricultural buildings and for temporary installations in working sites. Also for fixed installation in temporary buildings and cabins. When flexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6D At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4D Standard CENELEC HD 22.4 Fire propagation class F2 acc. to SS 424 14 75 and IEC 60332-1 Approval <HAR>, CE Material declaration H05-, H07RN-F, RDO/05RN-F Temperature range In continuous operation max. conductor temp. . . . .60˚C The cable is flexible down to . . . . . . . . . . . . . . . . . . . –25˚C 70 | Draka Keila Cables Max tensile stress (N) Total copper area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x 15 Design Conductor . . flexible and annealed copper acc. to IEC 60228 class 5 Insulation . . EPDM-rubber Identification of cores 2-core . . . . . 3-core . . . . . 4-core . . . . . 5-core . . . . . 7-core . . . . . blue, brown; green/yellow, blue, brown; green/yellow, brown, black, grey; green/yellow, blue, brown, black, grey; green/yellow, 6 cores black numbermarked 1-6; Sheath . . . . weather and oil resistant Bjuroflex rubber Marking E.g. DRAKAFLEX SEMKO <HAR> H07RN-F 5G1,5 Product Catalogue Automation, data and telecommunication cables DRAKAFLEX H07RN-F 450/750 V Rubber cable Number of cores x cross section of conductor mm2 2x1 2x1 2x1,5 2x1,5 2x2,5 2x2,5 3G1 3G1 3G1,5 3G1,5 3G1,5 3G2,5 3G2,5 3G2,5 3G4 3G6 4G1,5 4G1,5 4G1,5 4G2,5 4G2,5 4G2,5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G120 5G1,5 5G1,5 5G1,5 5G2,5 5G2,5 5G2,5 5G4 5G4 5G6 5G6 5G10 5G16 5G35 7G1,5 7G2,5 Product Catalogue Overall diameter (approx.) mm 8,3 8,3 8,9 8,9 10,7 10,7 8,8 8,8 9,6 9,6 9,6 11,5 11,5 11,5 14 15,2 10,5 10,5 10,5 12,4 12,4 12,4 14,9 16,5 22,7 26 32 35 41 47 53 58 11,7 11,7 11,7 13,5 13,5 13,5 16,9 16,9 18,7 18,7 25,5 28,3 39 15,1 17,4 Weight (approx.) kg/100 m 9,4 9,4 10,5 10,5 15,8 15,8 11,5 11,5 13,2 13,2 13,2 18,9 18,9 18,9 27,8 35,6 16,2 16,2 16,2 23,2 23,2 23,2 33,9 44,3 82,3 114,7 187,4 250,5 333,1 474,9 600,7 749,5 19,9 19,9 19,9 28,5 28,5 28,5 41,9 41,9 56,2 56,2 100,4 136,6 310,0 32,6 43,8 Standard delivery length m 100 500 100 500 100 500 100 500 50 100 500 50 100 500 500 500 50 100 500 50 100 500 500 500 500 500 500 500 500 250 250 250 50 100 500 50 100 500 50 500 50 500 500 500 250 500 500 Standard drum size /Package Coil K6 Coil K6 Coil K6 Coil K6 Coil Coil K6 Coil Coil K7 K7 K8 Coil Coil K6 Coil Coil K7 K8 K8 K11 K12 K16 K16 K18 K16 K18 K18 Coil Coil K7 Coil Coil K7 Coil K8 Coil K9 K12 K12 K12 K8 K9 Article number 952502070202 952502070205 952502080202 952502080205 952502100202 952502100205 952503070202 952503070205 952503080201 952503080202 952503080205 952503100201 952503100202 952503100205 952503110205 952503120205 952504080201 952504080202 952504080205 952504100201 952504100202 952504100205 952504110205 952504120205 952504130205 952504140205 952504150205 952504160205 952504170205 952504180204 952504190204 952504200204 952505080201 952505080202 952505080205 952505100201 952505100202 952505100205 952505110201 952505110205 952505120201 952505120205 952505130205 952505140205 952505160204 952507080205 952507100205 Draka Keila Cables | 71 Halogen-free and fire resistant cables DRAKAFLEX-TARMO H07BN4-F 450/750 V LSZH High quality rubber cable with an extended temperature range (-50°C – +90°C) Application fields Approval Halogen-free oil and weather resistant cable for connection to moveable items and motors, outdoors, in spaces with fire and explosion risks, in humid rooms with corrosive contents and in hostile surroundings, e.g. in industry and agriculture. Also for fixed installation in temporary buildings and cabins. Suitable for working sites. Use up to 1000 V AC is permitted for fixed, protected installation (in conduit or appliances) and also for motor connections of hoisting motors and the like. <HAR>, C Standard Total copper area x 15 N/mm2 HD 22.12 Part 6 (H07BN4-F) and HD 22.12 Part 4 (H07BB-F) and HD 22.4 (H07RN-F) HD 308 S2:2002 SS-EN 50267-2-2 (corrosive gases) SS-EN 50268-2 (smoke density) IEC 60811-2-1 (ozone protection) Design Fire propagation class F2 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN 50265-2-1 Temperature range In continuous operation max. conductor temp. . . . . 90˚C The cable is flexible down to . . . . . . . . . . . . . . . . . . . –50˚C 72 | Draka Keila Cables Material declaration DRAKAFLEX-TARMO H07BN4-F Bending radius 6 x overall diameter Max tensile stress (N) Conductor��������������flexible and annealed copper acc. to IEC 60228 class 5 Insulation����������������EPDM-rubber class EI6 Core identification���2-core: blue, brown; 3-core: green/yellow, blue, brown; 4-core: green/yellow, brown, black, grey; 5-core: green/yellow, blue, brown, black, grey; 7-core: green/yellow, 6 cores black number-marked 1–6; Sheath��������������������weather and oil resistant rubber, halogen-free; fulfills class EM2, EM6 and EM7 Marking e. g.����������DRAKAFLEX-TARMO H07BN4-F 5G 2,5 mm2 <HAR> Product Catalogue Halogen-free and fire resistant cables DRAKAFLEX-TARMO H07BN4-F 450/750 V LSZH High quality rubber cable with an extended temperature range (-50°C – +90°C) No. of cores x cross section of conductor mm2 2x1 2x2,5 3G1 3G1,5 3G1,5 3G2,5 3G4 3G6 4G1 4G1,5 4G2,5 4G6 4G10 4G16 5G1,5 5G1,5 5G2,5 5G2,5 5G4 5G6 5G10 5G16 7G1,5 7G2,5 Overall diameter (approx.) mm 8,3 11,1 8,8 10,0 10,0 11,5 13,5 15,6 10 10,5 12,4 16,8 22,9 26 11,6 11,6 13,5 13,5 16,9 19,0 25,5 28,5 14,8 17,4 Weight (approx.) kg/100 m 9,3 15,9 11,4 13,7 13,7 17,9 26,5 36,5 13,0 15,4 23,7 45,1 80,1 111,3 18,9 18,9 27,3 27,3 41,3 52,9 95,4 136,7 31,0 43,6 Standard delivery length m 500 500 500 100 500 500 500 500 500 500 500 500 500 500 50 500 50 500 500 500 500 500 500 500 Std. drum size /package Article number K6 K6 K6 Coil K6 K7 K7 K8 K6 K6 K7 K8 K11 K12 Coil K7 Coil K7 K8 K9 K12 K12 K8 K9 956502070205 956502100205 952503070205 952503080202 956503080205 956503100205 956503110205 956503120205 956504070205 956504080205 956504100205 956504120205 956504130205 956504140205 956505080201 956505080205 956505100201 956505100205 956505110205 956505120205 956505130205 956505140205 956507080205 956507100205 Electrical data Type Resistance at 200˚C 3G1,5 3G2,5 3G4 3G6 3G10 5G1,5 5G2,5 5G4 5G6 5G10 5G16 Ω/km 13,3 7,98 4,95 3,30 1,91 13,3 7,98 4,95 3,30 1,91 1,21 Ambient temperature Conversion factor 300˚C 1 Reactance at 200˚C and 50 Hz Current carrying capacity with 900˚C at conductor and ambient temperature at 300˚C Ω/km mA 0,106 23 0,101 32 0,100 43 0,094 56 0,090 77 0,117 21 0,113 29 0,110 38 0,107 50 0,101 68 0,096 92 450˚C 0,96 400˚C 0,91 450˚C 0,87 Voltage drop between phases V/A/km) 26,9 16,2 10,1 6,7 3,9 23,3 14,0 8,7 5,9 3,5 2,2 500˚C 0,82 Nominal values unless otherwise specified. NOTE Current ratings when installed in open air. National regulations must be followed. When the cable is accessible during operation by personnel, it is recommended that steps are taken to ensure that the outside jacket temperature does not exceed 500˚C. Following assumptions have been made: • 2–3 core cable – single phase circuit; • 4–5 core cable – three phase circuit. Voltage drop has been determined for cos ø =0,8 Product Catalogue Draka Keila Cables | 73 Halogen-free and fire resistant cables HULT(FLEX) LSOH FB 90 0,6/1 kV Fire resistant halogen-free power and control cable Application Construction Halogen-free power and control cable for low voltage applications 0,6/1 kV. Designed for vital installations during fire and have circuit integrity during 30 and 60 minutes. Suitable in wet environments. Multicore cables are specially applied for control engineering. Suited for use in public buildings tunnels, railway stations, oil and petrol chemical plants, etc where the danger to life may be greatly increased in the event of a power failure due to fire. Conductor . . . . . . . . solid conductor up to 10 mm2; 10 mm2 and larger conductor sizes stranded copper Insulation . . . . . . . . . ceramifiable silicone rubber; earthing core green/yellow polyethylene (PE) Cores . . . . . . . . . . . . cores stranded together Bedding . . . . . . . . . . halogen-free compound Outer sheet . . . . . . . polyolefin, halogen-free compound Properties and specifications Colour coding cores EN 50200 EN 50362, IEC 60331 and DIN 4102/12 Circuit Integrity During Fire IEC 60332-3-22 (Cat A) Flame Retardant IEC 60332-1 Self Extinguishing IEC 60754 Halogen-free IEC 61034 Low Smoke 1 core . . . . . . . . . . . . 2 cores . . . . . . . . . . . 3 cores . . . . . . . . . . . 4 cores . . . . . . . . . . . Remarks Other properties General, for signalling cables 30 minutes circuit integrity required and for power cables is a minimum of 60 minutes circuit Integrity required. Installation temp. . . min. –20˚C, max. +60˚C Outer sheet colour . . red Delivery . . . . . . . . . . on reels black blue brown blue brown green/yellow blue brown black green/yellow blue brown black grey 5 cores . . . . . . . . . . . blue brown black grey green/yellow Type Nom. core diam. Nom. outer diam. Weight Min. bending radius Max. pulling force Current Rating Conductor 20˚C AC Resistance 90˚C DC mm mm kg/km mm N A Ω/km Ω/km 2x1,5 3,4 11,6 175 95 400 26 12,1 15,4 3G1,5 3,4 12,1 190 100 435 26 12,1 15,4 4G1,5 3,4 13,9 230 115 575 23 12,1 15,4 5G1,5 3,4 14,3 260 115 610 23 12,1 15,4 7G1,5 3,4 14,9 265 120 665 17 12,1 15,4 2x2,5 3,4 12,4 210 100 460 36 12,1 15,4 3G2,5 3,8 13,0 230 105 505 36 7,41 9,45 4G2,5 3,8 15,3 340 125 700 32 7,41 9,45 5G2,5 3,8 18,0 410 145 970 25 7,41 9,45 7G2,5 3,8 16,1 350 130 775 23 7,41 9,45 4G6 4,9 15,6 420 125 730 54 3,08 3,93 5G6 4,9 17,0 510 140 865 54 3,08 3,93 4G10 7,1 20,0 775 160 1200 75 1,83 2,33 5G10 7,1 23,2 920 190 1610 75 1,83 2,33 4G16 8,3 22,0 1000 180 1450 100 1,15 1,47 5G16 8,3 26,6 1295 215 2120 100 1,15 1,47 Type Nom. core diam. Nom. outer diam. Weight Min. bending radius Max. pulling force Current Rating Conductor 20˚C AC Resistance 90˚C DC mm mm kg/km mm N A Ω/km Ω/km 4G25 9,6 26,0 1450 210 2025 127 0,727 0,927 5G25 9,6 30,2 1855 245 2735 127 0,727 0,927 4G35 10,8 30,0 1980 240 2700 158 0,524 0,669 5G35 10,8 33,7 2415 270 3405 158 0,524 0,669 4x50 12,1 34,6 2660 280 280 192 0,387 0,494 5G50 12,1 38,3 3240 310 310 192 0,387 0,494 4G70 13,1 40,0 3700 320 320 246 0.268 0.344 5G70 13,1 44,0 4440 355 355 246 0.268 0.344 5G95 15,8 49,4 5970 400 7320 298 0,193 0,248 4G120 17,2 50,0 6180 400 7500 346 0,153 0,198 5G120 17,2 54,4 7400 440 8875 346 0,153 0,198 4G150 19,2 55,0 7520 440 9075 399 0,124 0,161 4G185 21,5 61,0 9360 490 10000 456 0,0991 0,131 4G240 24,2 69,0 12120 555 10000 538 0,0754 0,102 1x300 26,9 33,0 3430 265 3265 703 0,0601 0,0831 1x400 30,2 37,0 4280 300 4105 823 0,0470 0,0685 Current rating: cables in free air according to IEC 60364-5-52 74 | Draka Keila Cables Product Catalogue Halogen-free and fire resistant cables HULT(FLEX) LSOH FB30/60 0,6/1 kV Fire resistant halogen-free power and control cable Application Construction Halogen-free power and control cable for low voltage applications 0,6/1 kV. Designed for vital installations during fire and have circuit integrity during 30 and 60 minutes. Suitable in wet environments. Multicore cables are especially applied for control engineering. Suited for use in public buildings tunnels, railway stations, oil and petrol chemical plants, etc where the danger to life may be greatly increased in the event of a power failure due to fire. Conductor . . . . . . . . . solid conductor up to 10 mm2; 10 mm2 and larger conductor sizes stranded copper Insulation . . . . . . . . . . ceramifiable silicone rubber; earthing core green/yellow polyethylene (PE) Cores . . . . . . . . . . . . . cores stranded together Bedding . . . . . . . . . . . halogen-free compound Outer sheet . . . . . . . . polyolefin, halogen-free compound Properties and specifications Colour coding cores EN 50200 EN 50362, IEC 60331 and DIN 4102/12 Circuit Integrity During Fire IEC 60332-3-22 (Cat A) Flame Retardant IEC 60332-1 Self Extinguishing IEC 60754 Halogen-free IEC 61034 Low Smoke 1 core . . . . . . . . . . . . . 2 cores . . . . . . . . . . . . 3 cores . . . . . . . . . . . . 4 cores . . . . . . . . . . . . Remarks Other properties General, for signalling cables 30 minutes circuit integrity required and for power cables is a minimum of 60 minutes circuit integrity required. Installation temp. . . . min. –20˚C, max. +60˚C Outer sheet colour . . red Delivery . . . . . . . . . . . on reels black blue brown blue brown green/yellow blue brown black green/yellow blue brown black grey 5 cores . . . . . . . . . . . . blue brown black grey green/yellow Type Nom. core diam. Nom. outer diam. Weight Min. bending radius Max. pulling force Current Rating Conductor 20˚C AC Resistance 90˚C DC mm mm kg/km mm N A Ω/km Ω/km 2x1,5 3,4 11,6 175 95 400 26 12,1 15,4 3G1,5 3,4 12,1 190 100 435 26 12,1 15,4 4G1,5 3,4 13,9 230 115 575 23 12,1 15,4 5G1,5 3,4 14,3 260 115 610 23 12,1 15,4 7G1,5 3,4 14,9 265 120 665 17 12,1 15,4 2x2,5 3,4 12,4 210 100 460 36 12,1 15,4 3G2,5 3,8 13,0 230 105 505 36 7,41 9,45 4G2,5 3,8 15,3 340 125 700 32 7,41 9,45 5G2,5 3,8 18,0 410 145 970 25 7,41 9,45 7G2,5 3,8 16,1 350 130 775 23 7,41 9,45 24G2,5 3,8 31,0 1280 250 2880 13,5 7,41 9,45 5G4 4,4 16,6 390 125 730 42 4,61 5,88 4G6 4,9 15,6 420 125 730 54 3,08 3,93 5G6 4,9 17,0 510 140 865 54 3,08 3,93 5G10 7,1 23,2 920 190 1610 75 1,83 2,33 Type Nom. core diam. Nom. outer diam. Weight Min. bending radius Max. pulling force Current Rating Conductor 20˚C AC Resistance 90˚C DC mm mm kg/km mm N A Ω/km Ω/km 5G16 8,3 26,6 1295 215 2120 100 1,15 1,47 5G25 9,6 30,2 1855 245 2735 127 0,727 0,927 5G35 10,8 33,7 2415 270 3405 158 0,524 0,669 4G50 12,1 34,6 2670 280 280 192 0,387 0,494 5G50 12,1 38,3 3240 310 310 192 0,387 0,494 5G70 13,1 44,0 4440 355 355 246 0.268 0.344 4G95 15,8 44,6 4895 360 5965 298 0,193 0,248 5G95 15,8 49,4 5970 400 7320 298 0,193 0,248 4G120 17,2 50,0 6180 400 7500 346 0,153 0,198 5G120 17,2 54,4 7400 440 8875 346 0,153 0,198 4G150 19,2 55,0 7520 440 9075 399 0,124 0,161 4G185 21,5 61,0 9360 490 10000 456 0,0991 0,131 4G240 24,2 69,0 12120 555 10000 538 0,0754 0,102 1x300 26,9 33,0 3430 265 3265 703 0,0601 0,0831 1x400 30,2 37,0 4280 300 4105 823 0,0470 0,0685 Current rating: cables in free air according to IEC 60364-5-52 Product Catalogue Draka Keila Cables | 75 Halogen-free and fire resistant cables Signal cable type 2300 FB 30 (mbzh) Halogen-free overall screened multipair signal cable with circuit integrity FE90/E30 Application Core colours • Special developed for those parts of the circuit installations where 30 minutes circuit integrity is required. • Suitable for applications mentioned in NPR 2576, especially where the demands of fire safety are high. • Halogen-free signalling cable for fixed installation. • Suitable for areas with many electromagnetic interference (EMI) signals. • Suitable for use in zone 1 and 2 (explosion safety). Standard colours . . in accordance with NEN 1597 Properties regarding fire performance Minimum installation temperature . . . . . . . . . . . . . . –20˚C Operating temperature . . . . . . . . min. –40˚C, max. +70˚C • Circuit integrity in accordance with NEN-EN 50200, in combination with all approved cable tray systems and mounting methods, in accordance with DIN 4102 part 12. • Fire Resistant, in accordance with IEC 60331. • Halogen-free, in accordance with NEN-EN 50267 (IEC 60754). • Low smoke, in accordance with NEN-EN-IEC 61034. • Flame retardant, in accordance with NEN-EN-IEC 60332-3-24 Cat C. • Self-extinguishing, in accordance with NEN-EN-IEC 60332-1. General properties • Good signal transmission at frequencies up to 100 kHz. • The construction of the cable largely prevents cross talk between the pairs. • The overall shield offers good protection against electromagnetic interference (EMI). Remarks • Not suitable for power installations. • 1,5 and 2,5 mm2 types suitable for 100 V audio systems. • When larger conductor size is required and screening unnecessary, type HULT FB 30 can be used. Construction Conductor . . . . . . . solid plain copper Insulation . . . . . . . . ceramifiable silicon rubber (XLSr) Cores . . . . . . . . . . . 2 cores twisted to a pair 4 cores twisted to a quad Assembly . . . . . . . . pairs or quad cabled and wrapped with glass tape Overall screen . . . . metallized polyester foil with underneath a drain wire of tinned copper Outer sheath . . . . . halogen-free flame retardant thermoplastic (LSOH) Standards/References KEMA 163, NEN 2535, NEN 2575, NEN-EN 50200, NEN-EN-IEC 60332-1, NEN-EN-IEC 60332-3, NEN-EN-IEC 61034, NEN-EN 50267, IEC 60754 Additional information: Construction data Diameter conductor . . . . . . . . . . . . . . . . . . . . . . . . . 0.8 mm Conductor category . . . . . . . . . . . . . . . . . . . . class 1 = solid Core insulation . . . . . . . . . . . . . . . . . . . . . . rubber (silicone) Core identification . . . . . . . . . . . . . . . . . . . . . . . . . . . .colour Screen over stranding element . . . . . . . . . . . . . . . . . . none Screen over stranding . . . . . . . . . . . . . . . . . . . . . . . . . . . .foil Longitudinal water blocking . . . . . . . . . . . . . . . . . . . . . . . no Radial water blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . no Protective sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no Armouring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no Material outer sheath . . . . . . . .copolymer, thermoplastic Colour outer sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red Halogen-free . . . . . . . . . . . . . . . . . .yes (acc. EN 50267-2-2) Flame retardant . . . . . . . . . . . . . . . . . . . .acc. EN 60332-1-2 Low smoke . . . . . . . . . . . . . . . . . . . . . yes (acc. EN61034-2) Circuit integrity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 60 Operating temperature, flexible . . . . . . . . . . . . . -20/70˚C Operating temperature, fix . . . . . . . . . . . . . . . . . . -40/90˚C Outdoor use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes Conductor material . . . . . . . . . . . . . . . . . . . . . . . . . Cu, bare Fire-resistant layer (core) . . . . . . . . . . . . . . . . . . . . . . . . yes Fire-resistant layer (lay-up) . . . . . . . . . . . . . . . . . . . . . . yes Armouring/reinforcement . . . . . . . . . . . . . . . . . . . . . . none Properties Oil resistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . good Electrical standards Standard KEMA K102 Others Sheath colour . . . . . . . . red Approval. . . . . . . . . . . . . KEMA-KEUR Packaging . . . . . . . . . . . coils, drums Electrical properties Voltage rating . . . . . . . . 300 V Test voltage . . . . . . . . . . 1 kV Insulation resistance . . > 100 MΩ/km 76 | Draka Keila Cables Product Catalogue Halogen-free and fire resistant cables Signal cable type 2300 FB 30 (mbzh) Halogen-free overall screened multipair signal cable with circuit integrity FE90/E30 Product number No. of cores and conductor cross section n x mm/mm2 127273 1 x 2 x 0,8 127274 1 x 4 x 0,8 128130 1 x 2 x 1,5 128126 1 x 2 x 2,5 127275 2 x 2 x 0,8 128127 2 x 2 x 1,5 128128 2 x 2 x 2,5 127276 4 x 2 x 0,8 128122 8 x 2 x 0,8 128123 12 x 2 x 0,8 128125 16 x 2 x 0,8 128129 20 x 2 x 0,8 Type 2301 2302Q 2301.150 2301.250 2302 2302.150 2302.250 2304 2308 2312 2316 2320 Nominal overall Minimum diameter bending radius Maximum Approx. weight tensile strength mm 6,6 7,5 8,9 10,1 9,6 14,1 14,9 10,5 13,0 14,4 15,8 17,7 N 15 30 45 75 30 90 150 60 120 180 240 300 mm 40 45 55 65 60 85 90 65 80 90 95 110 kg/km 55 80 100 125 85 210 260 130 200 265 330 410 Conductor resistance at 20°C, DC Ω/km 37,5 37,5000 12,1000 7,4100 37,5 12,1000 7,4100 37,5 37,5 37,5 37,5 37,5 Mutual capacitance µF/km 120 120 150 150 120 150 150 120 120 120 120 120 Type 2302Q FB30: 2 pairs constructed as a quad, the opposite cores form a pair. Product Catalogue Draka Keila Cables | 77 Halogen-free and fire resistant cables Signal cable type 2300 FB 90 (mbzh) Halogen-free overall screened multipair signal cable with circuit integrity FE90/E90 Application Core colours • Special developed for those parts of the circuit installations where 90 minutes circuit integrity is required. • Suitable for applications mentioned in NPR 2576, especially where the demands of fire safety are high. • Halogen-free signalling cable for fixed installation. • Suitable for areas with many electromagnetic interference (EMI) signals. • Suitable for use in zone 1 and 2 (explosion safety). Standard colours . . .in accordance with NEN 1597. Properties regarding fire performance Minimum installation temperature . . . . . . . . . . . . . . –20˚C Operating temperature . . . . . . . .min. –40˚C, max. +90˚C • Circuit integrity in accordance with NEN-EN 50200, in combination with all approved cable tray systems and mounting methods, in accordance with DIN 4102 part 12. • Fire Resistant, in accordance with IEC 60331. • Halogen-free, in accordance with NEN-EN 50267 (IEC 60754). • Low smoke, in accordance with NEN-EN-IEC 61034. • Flame retardant, in accordance with NEN-EN-IEC 60332-3-24 Cat C. • Self-extinguishing, in accordance with NEN-EN-IEC 60332-1. General properties • Good signal transmission at frequencies up to 100 kHz. • The construction of the cable largely prevents cross talk between the pairs. • The overall shield offers good protection. Remarks • Not suitable for power installations. • 1,5 and 2,5 mm2 types suitable for 100 V audio systems. • When larger conductor size is required and screening unnecessary, type HULT FB 30/60 can be used. Construction Conductor . . . . . . . . . . . solid plain copper Insulation . . . . . . . . . . . . ceramifiable silicon rubber (XLSr) Cores . . . . . . . . . . . . . . . 2 cores twisted to a pair 4 cores twisted to a quad Assembly . . . . . . . . . . . . pairs or quad cabled and wrapped with glass tape Overall screen . . . . . . . . metallized polyester foil with a drain wire of tinned copper underneath Outer sheath . . . . . . . . . halogen-free flame retardant thermoplastic (LSOH) Standards/References KEMA 163, NEN 2535, NEN 2575, NEN-EN 50200, NEN-EN-IEC 60332-1, NEN-EN-IEC 60332-3, NEN-EN-IEC 61034, NEN-EN 50267, IEC 60754 Additional information: Construction data Diameter conductor . . . . . . . . . . . . . . . . . . . . . . . . . 0,8 mm Conductor category . . . . . . . . . . . . . . . . . . . . class 1 = solid Core insulation . . . . . . . . . . . . . . . . . . . . . . rubber (silicone) Core identification . . . . . . . . . . . . . . . . . . . . . . . . . . . .colour Screen over stranding element . . . . . . . . . . . . . . . . . . none Screen over stranding . . . . . . . . . . . . . . . . . . . . . . . . . . . .foil Longitudinal water blocking . . . . . . . . . . . . . . . . . . . . . . . no Radial water blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . no Protective sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no Armouring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no Material outer sheath . . . . . . . .copolymer, thermoplastic Colour outer sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red Halogen-free (acc. EN 50267-2-2) . . . . . . . . . . . . . . . . . yes Flame retardant . . . . . . . . . . . . . . . . . . . .acc. EN 60332-1-2 Low smoke (acc. EN61034-2) . . . . . . . . . . . . . . . . . . . . . yes Circuit integrity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 90 Operating temperature, flexible . . . . . . . . . . . . . –20/70˚C Operating temperature, fix . . . . . . . . . . . . . . . . .–40/90˚C Outdoor use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes Conductor material . . . . . . . . . . . . . . . . . . . . . . . . . Cu, bare Fire-resistant layer (core) . . . . . . . . . . . . . . . . . . . . . . . yes Fire-resistant layer (lay-up) . . . . . . . . . . . . . . . . . . . . . . yes Armouring/reinforcement . . . . . . . . . . . . . . . . . . . . . . none Properties Oil resistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . good Electrical standards Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KEMA K102 Others Sheath colour . . . . . . . . red Approval. . . . . . . . . . . . . KEMA-KEUR Packaging . . . . . . . . . . . coils, drums Electrical properties Voltage rating . . . . . . . . 300 V Test voltage . . . . . . . . . . 1 kV Insulation resistance . . > 100 MΩ/km 78 | Draka Keila Cables Product Catalogue Halogen-free and fire resistant cables Signal cable type 2300 FB 90 (mbzh) Halogen-free overall screened multipair signal cable mbzh with circuit integrity FE90/E90 Product number No. of cores and conductor cross section n x mm/mm2 Type Nominal overall Minimum diameter bending radius Maximum Approx. weight tensile strength mm mm N kg/km Conductor resistance at 20°C, DC Ω/km 122171 122172 1x2x0,8 1x4x0,8 2301 2302Q 6,6 7,5 55 60 15 30 55 80 37,5 37,5000 122444 129171 1x2x1,5 1x2x2,5 2301.150 2301.250 8,9 10,1 75 85 45 75 100 125 7,4100 7,4100 122450 129172 2x2x0,8 2x2x1,5 2302 2302.150 9,6 12,2 80 100 30 90 85 210 37,5 12,1000 129173 122173 2x2x2,5 4x2x0,8 2302.250 2304 14,9 10,5 120 85 150 60 260 130 7,4100 37,5 122174 122175 8x2x0,8 12x2x0,8 2308 2312 13,0 14,4 105 120 120 180 200 265 37,5 37,5 122176 122177 16x2x0,8 20x2x0,8 2316 2320 15,8 17,7 130 145 240 300 330 410 37,5 37,5 Mutual capacitance µF/km 120 120 150 150 120 150 150 120 120 120 120 120 Type 2302Q FB90: 2 pairs constructed as a quad, the opposite cores form a pair. Product Catalogue Draka Keila Cables | 79 Halogen-free and fire resistant cables Draka SF/UTP Cat."5" FB 90 (mbzh) SF/UTP FB 90 cat "5" rd# 4x2x22 AWG DIN: J-02YSCH PiMF Additional information Application Minimum installation temperature . . . . . . . . . . . . . . . . 0˚C Operating temperature . . . . . . . . min. -20˚C, max. +60˚C Bending radius: fixed installation . . . . . . . . . . . . . . . . . . 4D Sheath colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .drums · Specially developed for those parts of circuit installations where 90 minutes circuit integrity is required · Primary (Campus), Secondary (Riser) and Tertiary (Horizontal) · IEEE 802.3 networks: 10Base-T, 100Base-T and 1000Base-T · IEEE 802.5 16 MB networks: ISDN, TPDDI and ATM · Industrial Ethernet application Properties regarding fire performance · Circuit integrity in accordance with NEN-EN 50200, BS 5839-1:2002 Clause 26.2e Enhanced, BS 8434-2:2003 · Fire resistant in acc. with IEC 60331-23 and BS 6387-C · Halogen-free in acc. with NEN-EN 50267 (IEC 60754) · Low smoke in accordance with NEN-EN-IEC 61034 · Flame retardant in accordance with NEN-EN 50266-2-3 and UL 1581 VW1 · Self-extinguishing in acc. with NEN-EN-IEC 60332-1 General properties · In areas effected by electromagnetic interference signals (EMC) · Construction of the cable is such that is approaches the properties of a Cat 5 cable as much as possible Remarks · There is also a single and a double pair construction with a conductor diameter of 0,63 mm Construction Conductor . . . . . . . solid plain copper Insulation . . . . . . . . silicon rubber (SiR) and polyethylene (PE) Cores . . . . . . . . . . . 2 cores twisted to a pair, wrapped with glass tape Overall screen . . . . metallized polyester foil Braiding . . . . . . . . . tinned copper wires, with a tinned copper drain wire underneath Outer sheath . . . . . halogen-free flame retardant thermoplastic (LSOH) Core colours Standard colours. . . white/blue and blue, white/orange and orange, white/green and green, white/brown and brown (in accordance with ISO/IEC 11801) Standards/References EIA/TIA 568A, ISO/IEC 11801, NEN-IEC 61156-6, NEN-EN 50173, NEN-EN 50288-4-2 80 | Draka Keila Cables Electrical data Insulation resistance LDC loop resistance Resistance unbalance Characteristic impedance Return loss Capacitance unbalance (pair to ground) Velocity ratio Construction data Conductor material Diameter conductor AWG-size Conductor category Number of cores Stranding element Core insulation Core identification Screen over stranding element Screen over stranding Material outer sheath Colour outer sheath Halogen-free (acc. EN 50267-2-2) Flame retardant Low smoke (acc. EN61034-2) Outer diameter Operating temperature, flexible Operating temperature, fix Category Armouring/reinforcement Protective sheath Weight Copper content Elements Number of stranding elements Properties Circuit integrity Max. tensile force Bending radius Electrical Characteristic impedance Applications Patch Product packing Product number Description ≥ 5000 MΩ/km ≤ 192 Ω/km ≤2% 100 ± 15 Ω (1 - 100 MHz) in acc. with ISO/IEC 11801 ≤ 1600 pF/km ± 57% Cu, bare 0,64 mm 22 Class 1 = solid 8 pairs other colour none other copolymer, thermoplastic red yes acc. EN 50266-2-4 yes approx. 10.5 mm -20/60˚C -20/60˚C 5 none no 125 kg 41 kg x2x 4 E 90 100 N 85 mm 100 Ω no 128690NN length of 1 m Product Catalogue Halogen-free and fire resistant cables BI(c) 250V Fire resistant halogen-free control cable Application Construction As alarm, control, and signal cables in places where during a fire the cable must sustain its functionality for a certain amount of time in order to protect people or machinery. For indoor and outdoor use. CENELEC HD 627-7B, IEC 60502-1, IEC 60332-3C, IEC 60331 and EN50200, IEC 60754-1 and 2, IEC 61034 Conductor . . . . . . . annealed, tinned copper, multistranded Insulation . . . . . . . . Mica-tape and EPDM-rubber, colour and numerical markings Shielding . . . . . . . . aluminium/polyester band and ground wire as a unified shielding Outer sheath . . . . . orange halogen-free polymer, production date and metric markings Certificates Colour coding cores CE, RoHS Conductor colour and pair . . . . . . . . . BLA/BLU and number tape on pair Four core . . . . . . . . BLA/BLU and BLA/BR Standards Properties Rated voltage Um . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250V Max allowed temperature for the cable: - continuous use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70˚C - in case of short circuit (max 5 sec). . . . . . . . . . . . . 160˚C Min recommended usage temperature . . . . . . . . . . –15˚C Min recommended bending radius - when installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D - for permanent installation as a one-time bend . . . . . . . 5D Max allowed tension during installation . . . .Ax50 N/mm2 Product Catalogue mm2 No. of cable pairs/cables and area of cross section Art No. Approx. diameter Approx. weight Standard length mm kg/km m Standard package Properties Capacitance of the cable pair Inductance Impedance / 1 kHz Conductor resistivity, max (20 ˚C) Loop resistivity, max (20 ˚C) µF/km mH/km Ω/km Ω/km Ω/km 2 x 0,75 460961 6,5 70 500 S4 1 x 4 x 0,75 460922 8,4 115 500 S4 2 x 2 x 0,75 461110 10,3 140 500 K7 4 x 2 x 0,75 461120 11,9 210 500 K7 80 0,75 330 24,8 49,6 Draka Keila Cables | 81 Halogen-free and fire resistant cables BFSI-EMC 1 kV Halogen-free and fire-resistant EMC compatible power cable Application Approvals Installations with rated voltage up to 1 kV, in case of requirement for a cable to function during a fire. This is a cable for indoor and outdoor use. Improved EMC screen according to EMC directive. Halogen-free cable is recommended when it is important to avoid heavy smoke and corrosive gases in case of a fire. National regulations for electrical installations must be followed. NEMKO, CE-marking, acc. to LVD. Max conductor temp . . . . . . . . . . . . . . . . . . . . . . . . . . 9O˚C Rated voltage U0/U . . . . . . . . . . . . . . . . . . . . . . . . . 0,6/1 kV CENELEC designation . . . . . . . . . . . . . . . . . . . . . N1ZC7Z1-R Standards applied CENELEC HD 604-5D Construction IEC 60502-1 Insulation IEC 60331 Fire Resistant IEC 60332-3C Flame Retardancy IEC 60754-1 and 2 Halogen-free IEC 61034 Low Smoke No. of cores and conductor area mm2 2 x 1,5/1,5 2 x 2,5/2,5 2 x 6/6 3 x 1,5/1,5 3 x 2,5/2,5 3 x 4/4 3 x 6/6 3 x 10/10 3 x 16/16 3 x 25/16 3 x 35/16 3 x 50/25 4 x 1,5/1,5 4 x 2,5/2,5 4 x 4/4 4 x 6/6 4 x 10/10 4 x 16/16 4 x 25/16 4 x 35/16 4 x 50/25 4 x 70/35 4 x 95/50 4 x 150/70 Construction Conductor . . . . . . . . . . . Insulation . . . . . . . . . . . . Bedding . . . . . . . . . . . . . Concentric conductor . . stranded copper Mica-tape and extruded XLPE halogen-free (PE/PEN conductor) copperfoil with overlap and concentric screen of copper wires. Outer sheath . . . . . . . . . halogen-free polymer Colour . . . . . . . . . . . . . . . black Mode of packing . . . . . . drum Marking Printed on outer sheath, designation and dimension. Meter marking and year of production. Conductor type 1) El. No. Art. No. FR FR FR FR FR FR FR FR FR FR FV FV FR FR FR FR FR FR FR FV FV FV FV FV 422605 422615 422640 422610 422620 422630 422645 422655 422660 422670 422675 422680 422612 422625 422635 422650 422657 422665 422673 422677 422685 422690 422693 422695 1046120 1046121 1046123 1046140 1046141 1046142 1046143 1046144 1046145 1046146 1046147 1046148 1046160 1046161 1046162 1046163 1046164 1046165 1046166 1046167 1046168 1046169 1046170 1046172 Outer diameter appr. mm 12 13 15 12 13 15 16 19 22 25 24 27 13 14 16 17 21 24 27 27 30 36 40 48 Approx. weight kg/km 150 190 300 180 220 290 380 570 860 1150 1380 1840 200 260 350 460 690 1050 1430 1750 2330 3280 4500 6700 1) FR =Stranded round. FV=Stranded sector shaped. Mode of packing and length can be changed. 82 | Draka Keila Cables Product Catalogue Halogen-free and fire resistant cables HULT(FLEX) LSOH 0,6/1 kV Halogen-free Power and Control Cable Application Colour coding cores Halogen-free Power and Control cable for Low Voltage applications 0,6/1 kV. Suitable in wet environments. Multicore cables are especially applied for control engineering. Suited for use in Public buildings tunnels, Railway Stations, Oil and Petrol. 1 core . . . . . . . . . . . black 2 cores . . . . . . . . . . blue brown 3 cores . . . . . . . . . . blue brown green/yellow 4 cores . . . . . . . . . . blue brown black green/yellow blue brown black grey 5 cores . . . . . . . . . . blue brown black grey green/yellow Properties and Specifications IEC 60332-3-22 (Cat A) Flame Retardant IEC 60332-1 Self Extinguishing IEC 60754 Halogen-free IEC 61034 Low Smoke Other properties Min. installation temperature . . . . . . . –20˚C, max. +60˚C Max. conductor temperature . . . . . . . . . . . . . . . . . . . .90˚C Outer sheet colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . on reels Construction Conductor . . . . . . . Solid conductor up to 10 mm2 10 mm2 and larger conductor sizes stranded copper Insulation . . . . . . . . polyethylene (PE) Cores . . . . . . . . . . . cores cabled together Bedding . . . . . . . . . halogen-free compound Outer sheet . . . . . . polyolefin, halogen-free compound Type 2x1,5 2x2,5 3G1,5 3G2,5 4G1,5 4G2,5 4G4 4G6 4G10 4G16 4G25 4G35 4G50 4G70 4G95 4G150 5G1,5 Nom. outer diam. Weight Min. Current Conduc- Resist- Working Working bending rating tor 20°C ance induct- capaci90°C DC ance radius AC tance mm 9,5 10,3 9,9 10,7 10,7 11,5 12,6 13,8 17,1 19,7 23,8 26,7 31,6 36,6 41,8 51,3 11,5 kg/km 130 165 150 190 175 220 295 390 620 895 1360 1770 2445 3410 4550 7180 200 Product Catalogue mm 50 55 50 55 55 60 80 85 105 120 170 135 160 185 210 260 60 A 26 36 26 36 23 32 42 54 75 100 127 158 192 246 298 399 23 Ω/km 12,1 7,41 12,1 7,41 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,124 12,1 Ω/km 15,4 9,45 15,4 9,45 15,4 9,45 5,88 3,93 2,33 1,47 0,927 0,669 0,494 0,344 0,248 0,161 15,4 mH/km 0,33 0,31 0,33 0,31 0,37 0,35 0,33 0,32 0,29 0,28 0,28 0,26 0,25 0,25 0,25 0,24 0,41 µF/km 55 63 56 63 123 142 150 159 185 212 227 240 242 245 255 270 128 Type 5G2,5 5G4 5G6 5G10 5G16 5G25 5G35 5G50 5G70 5G95 5G120 5G150 7G1,5 7G2,5 12G1,5 12G2,5 24G1,5 Nom. outer diam. Weight Min. Current Conduc- Resist- Working Working bending rating tor 20°C ance induct- capaci90°C DC ance radius AC tance mm 12,5 13,7 15 18,7 21,5 26,2 29,5 34,9 40,5 46,5 51,4 57,6 12 13,1 15,2 16,8 20,2 kg/km 260 350 460 745 1080 1655 2160 2990 4180 5710 7130 8900 215 285 330 440 585 mm 75 85 90 115 155 185 150 175 205 235 260 290 60 80 95 105 145 A 32 42 54 75 100 127 158 192 246 298 346 399 17 23 13 18 9,5 Ω/km 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 12,1 7,41 12,1 7,41 12,1 Ω/km 9,45 5,88 3,93 2,33 1,47 0,927 0,669 0,494 0,344 0,248 0,198 0,161 15,4 9,45 15,4 9,45 15,4 mH/km 0,38 0,36 0,34 0,32 0,31 0,3 0,3 0,27 0,23 0,22 0,21 0,2 - µF/km 147 155 164 190 217 232 243 245 247 268 280 285 ≤ 150 ≤ 150 ≤ 150 ≤ 150 ≤ 150 Draka Keila Cables | 83 Halogen-free and fire resistant cables EQQ-Light 300/500 V Halogen-free installation cable Application fields Approval Halogen-free, no emittance of corrosive gases, low smoke density in case of fire. Fixed installation, in pipes, ducts, in or under plaster, also suspended in catenary system. Indoors and outdoors, however not in ground or water. UV protected (1) for outdoor use in the Nordic countries. SEMKO, S-marked, C Alternative Designation EKK-Light SE-S05Z1Z1-U Bending radius Standard 8D (4D in final installation, bent only once) SS 424 02 19-5 and EN 50265-2-1 (corrosive gases) EN 50268-2 (smoke density) Design Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN 50265-2-1 Temperature range In continuous operation max. conductor temp. . . . . 70˚C Lowest cable temperature under installation. . . . . . –15˚C and below 0˚C special precaution shall be taken Number of cores x Overall diameter cross section of con- (approx.) ductor mm2 mm Without earth conductor 2 x 1,5 8,6 With earth conductor 3G1,5 8,6 3G1,5 8,6 3G1,5 8,6 3G2,5 10,7 3G2,5 10,7 3G2,5 10,7 4G1,5 10,1 4G1,5 10,1 4G1,5 10,1 5G1,5 10,2 5G1,5 10,2 5G1,5 10,2 5G2,5 12,8 5G2,5 12,8 5G2,5 12,8 Material declaration EQQ-Light PVC alternative Conductor��������������solid and annealed copper acc. to IEC 60228 class 1 Insulation����������������halogen-free compound Core identification��2-core: blue, brown 3-core: green/yellow, blue, brown 4-core: green/yellow, blue, brown, black 5-core: green/yellow, blue, brown, black, grey Filler������������������������halogen-free compound Sheath��������������������halogen-free compound, white, meter marked Marking������������������������e.g. DRAKA EQQ-LIGHT 3G1,5 300/500 V LSZH S Weight (approx.) Standard delivery length Standard drum size Article number /Package kg/100 m m 10,0 500 K6 0445065 10,9 10,9 10,9 16,9 16,9 16,9 14,2 14,2 14,2 15,3 15,3 15,3 23,9 23,9 23,9 50 250 500 50 150 500 50 200 500 50 150 500 50 150 500 Coil K4,5 K6 Coil K4,5 K6 Coil K4,5 K6 Coil K4,5 K6 Coil K4,5 K7 0445001 0445003 0445005 0445011 0445013 0445015 0445021 0445023 0445025 0445041 0445043 0445045 0445051 0445053 0445055 1) UV – ultraviolet radiation Nominal values unless otherwise specified. 84 | Draka Keila Cables Product Catalogue Halogen-free and fire resistant cables EQLQ 450/750 V Halogen-free installation cable Application fields Material declaration Halogen-free, no emittance of corrosive gases, low smoke density in case of fire. Fixed installation, indoors and outdoors, in pipes, ducts, in or under plaster, also suspended in catenary system. In ground, only if the cable is protected against mechanical damage. EQLQ Alternative designation Bending radius Design Standard Conductor . . . . . . . . . . . . solid and annealed copper acc. to IEC 60228 class 1 Insulation . . . . . . . . . . . . . halogen-free polymer SS 424 02 19-4 In Applicable Parts HD 604 Halogen-free Materials EN 50267-2-2 Corrosive Gases EN 50268-2 Low Smoke Density Core identification Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN 50265-2-1 Temperature range In continuous operation max. conductor temp . . . . . 70˚C Lowest cable temperature under installation . . . . . –15˚C and below 0˚C special precaution shall be taken Approval SEMKO, S-marked, CE Product Catalogue EKLK 12D (6D in final installation, bent only once) N07Z1A5EZ1-U Number of cores x cross section of conductor n x mm2 3G1,5 3G1,5 3G1,5 3G2,5 3G2,5 3G2,5 4G1,5 4G1,5 4G1,5 4G2,5 4G2,5 5G1,5 5G1,5 5G1,5 5G2,5 5G2,5 5G2,5 PVC alternative Overall diameter (approx.) mm 9,9 9,9 9,9 11,8 11,8 11,8 11,2 11,2 11,2 13,3 13,3 12 12 12 13,6 13,6 13,6 Weight (approx.) kg/100 m 13,2 13,2 13,2 18,7 18,7 18,7 17,2 17,2 17,2 26,1 26,1 17,8 17,8 17,8 26,8 26,8 26,8 3-core . . . . . . . . . . . . . . . . green/yellow, blue, brown 4-core . . . . . . . . . . . . . . . . green/yellow, blue, brown, black 5-core . . . . . . . . . . . . . . . . green/yellow, blue, brown, black, grey Filler . . . . . . . . . . . . . . . . . halogen-free polymer Concentric conductor . . . aluminium with bonded PE in contact with drain wire of tinned copper Sheath . . . . . . . . . . . . . . . halogen-free polymer, white, meter marked Marking . . . . . . . . . . . . . . e.g. EQLQ 3G1,5 450/750 V F3 LSZH DRAKA S. Standard delivery length m 50 250 500 50 150 500 50 200 500 50 500 50 150 500 50 150 500 Standard drum size/package Article number Coil K4,5 K6 Coil K4,5 K7 Coil K4,5 K6 Coil K7 Coil K4,5 K7 Coil K4,5 K7 460001 460003 460005 460011 460013 460015 460021 460023 460025 460031 460035 460041 460043 460045 460051 460053 460055 Draka Keila Cables | 85 Halogen-free and fire resistant cables FQLQ 450/750 V Halogen-free installation cable Application fields Material declaration Halogen-free, no emittance of corrosive gases, low smoke density in case of fire. Fixed installation, indoors and outdoors, in pipes, ducts, in or under plaster, also suspended in catenary system. In ground, only if the cable is protected against mechanical damage. EQLQ, FQLQ Alternative designation N07Z1A5EZ1-R Standard SS 424 02 19-4 In Applicable Parts HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 & EN 50265-2-1 Temperature range In continuous operation max. conductor temp. . . . . 70˚C Lowest cable temperature under installation. . . . . . –15˚C and below 0˚C special precaution shall be taken. Approval Bending radius 12D (6D in final installation, bent only once) Design Conductor������������������������� stranded and annealed copper acc. to IEC 60228 class 2 Insulation��������������������������� halogen-free compound Core identification 3-core��������������������������������� green/yellow, blue, brown 4-core��������������������������������� green/yellow, blue, brown, black 5-core��������������������������������� green/yellow, blue, brown, black, grey 7-core��������������������������������� green/yellow, 6 cores black number-marked 1-6 Filler����������������������������������� halogen-free compound Concentric conductor����� aluminium with bonded PE in contact with drain wire of tinned copper Sheath������������������������������� halogen-free compound, white, meter marked Marking����������������������������� e.g. FQLQ 5G2,5 450/750 V LSZH DRAKA SE F3 S. SEMKO, S-marked CE Number of cores x cross section of conductor n x mm2 3G1,5 3G2,5 4G1,5 5G1,5 5G2,5 7G1,5 7G2,5 86 | Draka Keila Cables Overall diameter (approx.) mm 10,3 12,4 11,6 12,4 14,1 13 15,4 Weight (approx.) kg/100 m 15,7 20,7 18 20,6 28,5 24,5 34,9 Standard delivery length m 500 500 500 500 500 500 500 Standard drum size/Package Article number K6 K7 K7 K7 K7 K7 K8 5,17503E+11 5,17503E+11 5,17504E+11 5,17505E+11 5,17505E+11 5,17507E+11 5,17507E+11 Product Catalogue Halogen-free and fire resistant cables AXQJ 0,6/1 kV Halogen-free power cable Application fields Material declaration Halogen-free and fire classified cable. No emittance of corrosive gases, low smoke density in case of fire. Open, fixed installation, indoors and outdoors, in pipes and in ground/water. In switchgear rooms and rooms where explosions may occur. Can be carefully ploughed down. AXQJ Alternative designation PVC alternative AKKJ Bending radius At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D SE-N1Z1CZ1-AS Standard Design SS 424 14 18 CENELEC HD 603 Part 3 Section L CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN 50265-2-1 Temperature range In continuous operation max. conductor temp. . . . . 70˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken. Approval Conductor������������������������� stranded, sector-shaped and annealed aluminium acc. to IEC 60228 class 2 Insulation��������������������������� halogen-free compound Core identification 3-core��������������������������������� brown, black, grey 4-core��������������������������������� brown, black, grey, blue Filler����������������������������������� halogen-free, extruded compound or plastic tape Concentric conductor����� annealed copper wires and counter spiral of copper Sheath������������������������������� halogen-free compound, black Marking ��������������������������� e.g. AXQJ 0,6/1 kV 3x240/72 F3 S GREEN LINE CABLES DRAKA SE “Date”, meter marked. SEMKO, S-marked EC Number of cores x cross section of conductor mm2 3x50/15 3x70/21 3x95/29 3x120/41 3x150/41 3x185/57 3x240/72 4x50/15 4x70/21 4x95/29 4x120/41 4x150/41 4x185/57 4x240/72 Product Catalogue Overall diameter (approx.) mm 26,4 29,9 33,5 37,4 40,8 45,4 49,7 29,7 33,6 37,7 42,2 46,2 51,3 56,2 Weight (approx.) kg/100 m 92,1 122,6 158 176 208,5 265,1 333,8 112,7 150,5 194,5 217,1 261,4 329,4 415,2 Standard delivery length m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Standard drum size Article number K12 K12 K14 K16 K18 K20 K22 K12 K16 K16 K18 K18 K20 K22 1620 1630 1640 1650 1660 1670 1680 1720 1730 1740 1750 1760 1770 1780 Draka Keila Cables | 87 Halogen-free and fire resistant cables EXQJ 0,6/1 kV Halogen-free power cable Application fields PVC alternative Halogen-free, no emittance of corrosive gases, low smoke density in case of fire. Open, fixed installation, indoors and outdoors, in pipes and in ground/water. In switchgear rooms and rooms where explosions may occur. Can be carefully ploughed down. EKKJ Bending radius Alternative designation At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D SE-N1Z1CZ1-U Design Standard Conductor������������������������� solid, round and annealed copper acc. to IEC 60228 class 1 Insulation��������������������������� halogen-free compound Core identification 3-core��������������������������������� brown, black, grey 4-core��������������������������������� brown, black, grey, blue Filler����������������������������������� halogen-free compound Concentric conductor����� annealed copper wires and counter spiral of copper Sheath������������������������������� halogen-free compound, black, meter marked SS 424 14 18 CENELEC HD 603 Part 3 Section L CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 Temperature range In continuous operation max. conductor temp. . . . . 70˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken Marking E.g. EXQJ 3X4/4 0,6/1 kV F3 S GREEN LINE CABLES DRAKA SE “year”. Approval SEMKO, S-marked CE Number of cores x cross section of conductor mm2 3x2,5/2,5 3x4/4 3x6/6 3x10/10 4x2,5/2,5 4x4/4 4x6/6 4x10/10 Overall diameter (approx.) mm 14 15 16 18,3 14,8 15,9 17,7 19,6 Weight (approx.) kg/100 m 24,5 31,9 41 61,3 28,1 37 50,7 72,8 Standard delivery length m 500 500 500 500 500 500 500 500 Standard drum size Article number K07 K07 K08 K09 K07 K07 K09 K11 2110031002 2110031102 2110031202 2110031302 2110041002 2110041102 2110041202 2110041302 Nominal values unless otherwise specified. 88 | Draka Keila Cables Product Catalogue Halogen-free and fire resistant cables FXQJ 0,6/1 kV Halogen-free power cable Application fields Temperature range Halogen-free, no emittance of corrosive gases, low smoke density in case of fire. Open, fixed installation, indoors and outdoors, in pipes and in ground/water. In switchgear rooms and rooms where explosions may occur. Can be carefully ploughed down. In continuous operation max. conductor temp. . . . . 70˚C Lowest cable temperature under installation. . . . . –20˚C and below 0˚C special precaution shall be taken Alternative designation SE-N1Z1CZ1-R, SE-N1Z1CZ1-S At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D Standard Design SS 424 14 18 CENELEC HD 603 Part 3 Section L CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Conductor������������������������� stranded and annealed copper acc. to IEC 60228 class 2 ≤ 35 mm2 round 50–240 mm2 sector-shaped Insulation��������������������������� halogen-free compound Core identification 3-core��������������������������������� brown, black, grey 4-core��������������������������������� brown, black, grey, blue Filler����������������������������������� halogen-free, extruded compound or plastic tape Concentric conductor����� annealed copper wires and counter spiral of copper Sheath������������������������������� halogen-free compound, black, meter marked Fire propagation class F3 acc. to SS 424 14 75 and IEC 60332-1 Approval SEMKO, S-marked CE PVC-alternative FKKJ Bending radius Marking E.g. FXQJ 3X240/120 0,6/1 kV F3 (S) GREEN LINE CABLES DRAKA SE “year”. Number of cores x cross section of conductor mm2 3x16/16 3x25/16 3x35/16 3x50/25 3x70/35 3x95/50 3x120/70 3x150/70 3x185/95 3x240/120 4x16/16 4x25/16 4x35/16 4x50/25 4x70/35 4x95/50 4x120/70 4x150/70 4x185/95 4x240/120 Overall diameter (approx.) mm 20,6 23,4 25,8 26,4 29,9 34,3 37,6 41 46,4 51,1 22,3 25,4 28,1 29,7 33,7 38,6 42,3 46,5 52,6 57,6 Weight (approx.) kg/100 m 94 128,2 162,1 189,8 244,8 332,6 419,5 506,6 633,9 829 112 155,7 198,7 239,8 312,4 424,4 533,5 650,6 811 1060,6 Standard delivery length m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Standard drum size Article number K11 K11 K11 K11 K14 K14 K14 K18 K18 K22 K11 K12 K12 K12 K12 K16 K16 K18 K20 K22 2115031402 2115031502 2115031602 2115031702 2115031802 2115031902 2115032002 2115032102 2115032202 2115032302 2115041402 2115041502 2115041602 2115041702 2115041802 2115041902 2115042002 2115042102 2115042202 2115042302 Nominal values unless otherwise specified. Product Catalogue Draka Keila Cables | 89 Drums Drum handling guide The right way to transport, handle and move drums A cable is a valuable product. The cable transportation package is usually a drum. The battens on the drum seem thick enough to remain unbroken. But, with a cable weighing more than 4 tons, it becomes very vulnerable. If the handling is done correctly, the drum will protect the cable from transportation damages. If the drum is damaged, the cable can also be damaged. The damage might not be discovered until after installation, when repairs can be extremely expensive. drum. Keep the drum from touching other drums and well balanced. Take care not to give any impact to the drum being lowered. In case a cable drum must be temporarily in a waiting position above the deck for reason of cargo handling, keep it hoisted and do not put it down on the deck. The purpose of these instructions is to tell you how damages can be avoided by correct drum handling. Keep the drum upright Always store and move the drum in an upright position. The drum is constructed to be handled in an upright position - it will not stand up to being lifted lying flat. When kept upright, the cable layers will not entangle and cause problems when the cable is laid. Keep the cable protected until the cable is used. Roll in direction of arrows only Handling with fork-lift truck The forks of the truck must be longer than the width of the drum, so that the lagging is not damaged. Different widths of drums should be painted on the forks enabling the operator to select the correct position for the drum size. When moving the drum, tilt the truck mast so that the drum remains in the fork and the points don’t touch the ground. Raise the forks of the forklift sufficiently 15-20 cm above the ground. Insufficient raising may cause the drum to be dragged on the ground and eventually damaged or dropped off the forks if the ground surface is uneven. Don’t release the drum until the truck has sopped completely. Don’t push the drum with the truck. Leave sufficient room between each drum so that the fork doesn’t damage the drum. Always roll the drum in direction of the arrow. This way the cable will not unwind and loosen on the drum. But, this does not mean that the drum can be rolled freely. When the drum must be rolled for some reason or other, roll it in the direction of arrow over a distance not exceeding 5 meters. If it is rolled beyond the 5 m limit, the cable wind will come too tight and cut off the rope holding the cable end. This will deform the cable and make it unfit for use. Nail with caution In case the planks have to be refastened, the nailing should be done carefully in the middle of the drum flange. If label or something similar is attached to the drum with nails, make sure that they don’t touch the cable. Lift the drum without damage When lifting the drum, use a shaft through the centre of the drum and a wire spreader. If these are not available, lift with as long a wire as possible, so that the sides of the drum are not damaged. Make sure that the cable head is not pinched between wire and 90 | Draka Keila Cables Product Catalogue Drums Drum handling guide The right way to transport, handle and move drums Secure the drums firmly Fasten the drums firmly The round-shaped cable drum rolls easily. It is an a very unstable state because its center section is vacant and the whole weight rests on its peripheral section. Make sure to use drags to prevent drums from rolling during storage. Large drums should be lifted from the base onto triangular or square wedges. The wedges should be positioned by the flanges or the full width of drum. Sideways movement is eliminated by planks attached to the side of the drum. In case smaller drums are placed between larger ones, each drum has to be supported separately to prevent damages. The drum is fastened to the base through the centre hole or across the flanges with wires or ropes. Avoid stacking Stacking of drums should be avoided. If, however, one is forced to do this, same size of drums should be positioned exactly on top of each other. If smaller drums are stacked on larger drums, planks of the size of the larger drum is placed in between to protect the flanges. Above method is recommended even when same size drums are stacked. Secure drums to be transported To prevent movement of drums, a combination of wedges and transportation support should be used and tied down front and rear. Higher drums should be tied in side direction as high up as possible. The drums loaded first should rest against the front board (observing shaft weight). If the last drum doesn’t lean against the end board or the board is not strong enough, the drum must be secured. Product Catalogue Don’t drop drums The drum must not be dropped from the vehicle. The drum is to be lifted either by winch of fork-lift truck as mentioned in “lifting the drum”. If above mentioned equipment is not available, best possible conditions must be created to unload the drums from the vehicle. A platform of the same height as the vehicle or a point in the terrain will guarantee that no damage will occur. Make sure when unloading that the drum doesn’t strike another drum. Draka Keila Cables | 91 Drums Drum dimensions and weights D A C E B Drums type 5C 6A 6C 7E 8E 9F 9FV 11G 11GV 13G 15G 16L 18M 20P 22P 22P5 26U 26U8 28W 28WO 30Y 32Z K6 K7 K8 K9 K11 K12 K14 K16 K18 K20 K22 K24 K26 K28 K30 92 | Draka Keila Cables Dimensions mm A 500 600 600 700 800 900 900 1100 1100 1300 1500 1600 1800 2000 2200 2200 2600 2600 2800 2800 3000 3200 600 700 800 900 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Weight kg/drum B 500 400 500 610 610 660 675 725 755 760 760 970 1025 1155 1155 1155 1455 1455 1610 1610 1810 1970 468 580 580 630 762 982 982 1018 1075 1190 1190 1205 14 48 1650 1800 C 250 250 250 325 375 425 425 500 500 600 700 800 1100 1100 1200 1500 1500 1800 1500 2000 2200 2400 250 325 375 425 575 675 800 950 1100 1300 1400 1400 1500 1500 1500 D 400 300 400 500 500 550 550 600 600 600 600 800 850 960 960 960 1200 1200 1300 1300 1500 1600 400 500 500 550 650 850 850 850 850 1000 1000 1000 1200 1350 1500 E 55 55 55 55 55 82 82 82 82 82 82 82 82 82 82 82 123 123 123 123 123 132 75 75 75 75 106 106 106 106 132 132 132 132 132 132 132 10 10 16 20 26 40 50 70 85 105 150 185 260 350 445 460 805 830 1050 1100 1300 1900 12 20 25 34 55 90 115 195 230 340 410 450 900 1180 1500 Product Catalogue The mission of Draka Keila Cables is to be a profitable Draka enterprise. We have a competent sales organization that is targeted to the customers and we produce and sell a wide range of cable products to the present and future information and electricity networks. We wish to achieve the satisfaction of customers, employees and owners by making decisions that would enable the environment-friendly development of Draka Keila Cables by minimizing our environmental impacts and improving the effectiveness of our management system constantly. Upon the implementation of ISO 9001:2008, ISO 14001:2004 and OHSAS 18001:2007 requirements, Keila Kaabel proceeds from the needs of the customers and the instructional requirements. AS Draka Keila Cables Paldiski Road 31 76606 Keila Estonia Phone +372 674 7466 Fax +372 674 7468 www.draka.ee Member of Prysmian Group www.prysmian.com All information concerning material properties, fire performance, construction, electrical and technical data, prices etc. reflects our current level of knowledge and is provided without obligation. Dimensions and weights are only given as a guide. The technical specifications may change any time without prior notice.