Product Catalogue
Environment and quality policy
Draka Keila Cables Ltd. wishes to gain satisfaction of the customers, employees and owners
without damaging of environment. In Draka
Keila Cables Ltd. the decisions are made, which
allow to develop the company and to save environment at the same time and on the assumption of this principle continuously to improve
the system of management.
In Draka Keila Cables Ltd. there is used the
multistage program of the quality control, which
covers production process from development of
the cables, purchasing of raw materials and production of installation and power cables to the
documentation of supplemental examinations
and tests.
The quality and environmental management
system of Draka Keila Cables Ltd. has appraised
and approved by Lloyd’s Register Quality Assurance Limited, which performs regular audits according to standard of quality system
ISO 9001 and ISO 14001.
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General information. . . . . . . . . . . . . . . . . . . . . . . . . . 3
Basic cable data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Power cables
ACSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
HK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
AS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
AXMK-PLUS and XMK-PLUS 1-core. . . . . . . . . . . . 13
AXPK-PLUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
AXPK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
EMC-Line 1 kV (IFSI). . . . . . . . . . . . . . . . . . . . . . . . . 18
AMCMK 3 1/2-core . . . . . . . . . . . . . . . . . . . . . . . . . . 20
AMCMK 4 1/2-core. . . . . . . . . . . . . . . . . . . . . . . . . . 22
MCMK 3-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MCMK 4-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
MCMK 5-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
MCCMK 4-core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MCCMK 5-core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MCMK 3 1/2-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
MCMK 4 1/2-core. . . . . . . . . . . . . . . . . . . . . . . . . . . 32
MCMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
ARLC Aluminium Road Lighting Cable. . . . . . . . . 35
EX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
AMKA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
AHXAMK-W 6/10 (12) kV. . . . . . . . . . . . . . . . . . . . . 38
AHXAMK-W 12/20 (24) kV. . . . . . . . . . . . . . . . . . . . 39
AXLJ-TT 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
AXLJ-TT 14/24 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . 41
AXLJ-TTCL TSLF 14/24 kV. . . . . . . . . . . . . . . . . . . 42
AXLJ-TT 7/12 kV (3-core). . . . . . . . . . . . . . . . . . . . . 43
AXLJ-TT 14/24 kV (3-core). . . . . . . . . . . . . . . . . . . 44
AXLJ-RMF 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . 45
AXLJ-RMF 14/24 kV. . . . . . . . . . . . . . . . . . . . . . . . . 46
AXQJ-RMF 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . 47
AXQJ-RMF 14/24 kV. . . . . . . . . . . . . . . . . . . . . . . . . 48
AXQJ-F 7/12 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
AXQJ-F 14/24 kV . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
PAS-W 20 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Installation cables and wires
PL / ML / H07V-U. . . . . . . . . . . . . . . . . . . . . . . . . . . 53
PK / MK / H07V-R . . . . . . . . . . . . . . . . . . . . . . . . . . 54
MK 90 / H07V2-R. . . . . . . . . . . . . . . . . . . . . . . . . . . 55
MKEM 90 / H07V2-K. . . . . . . . . . . . . . . . . . . . . . . . 56
MMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
EKLK 450/750 V . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
PPJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
MSK / H05VV-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
PROFIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Automation, data and telecommunication cables
JAMAK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JAMAK ARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOMAK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KLMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PULS 2,5 75V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMOHBU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H05RN-F; RDO/05RN-F 300/500 V. . . . . . . . . . .
DRAKAFLEX H07RN-F 450/750 V. . . . . . . . . . . .
62
63
64
65
66
67
68
69
70
Halogen-fee and fire resistant cables
DRAKAFLEX-TARMO
H07BN4-F 450/750 V LSZH . . . . . . . . . . . . . . . . . 72
HULT(FLEX) LSOH FB 90 0,6/1 kV . . . . . . . . . . . . 74
HULT(FLEX) LSOH FB 30/60 0,6/1 kV . . . . . . . . . 75
Signal cable type 2300 FB 30 (mbzh). . . . . . . . . .76
Signal cable type 2300 FB 90 (mbzh) . . . . . . . . . 78
Draka SF/UTP Cat."5" FB 90 (mbzh). . . . . . . . . . . 80
BI(c) 250V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
BFSI-EMC 1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
HULT(FLEX) LSOH 0,6/1 kV. . . . . . . . . . . . . . . . . . 83
EQQ-Light 300/500 V. . . . . . . . . . . . . . . . . . . . . . . 84
EQLQ 450/750 V. . . . . . . . . . . . . . . . . . . . . . . . . . . 85
FQLQ 450/750 V. . . . . . . . . . . . . . . . . . . . . . . . . . . 86
AXQJ 0,6/1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
EXQJ 0,6/1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
FXQJ 0,6/1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Drums
Drum handling guide. . . . . . . . . . . . . . . . . . . . . . . . 90
Drum dimensions and weights. . . . . . . . . . . . . . . . 92
Introduction
Draka Keila Cables was established in 1992. Company’s
equity holders are Draka NK Cables Ltd. (former Nokia
Cables), with 66%, and an Estonian electrical equipment producing company AS Harju Elekter with 34%.
Through Draka NK Cables Keila Kaabel belongs to DRAKA Holding, one of the biggest cable producers in the
world. The group consists of 59 entities located in 24
countries in Europe, Americas and Asia.
The headquarter and manufacturing facilities of Draka
Keila Cables are located on territory of AS Harju Elekter in Keila, Estonia. Our major markets are Baltic
countries. Representative offices have been set up in
Riga and Vilnius to ensure proper communication with
our customers in Latvia and Lithuania.
Draka Keila Cables is focused on the three main product groups: low-voltage and special purpose cables,
power cables and telecommunication cables. Our
goal is to provide customers the best solutions for
transmission of energy and information. Cables are
produced in a wide range, according to needs of customers and current standards. Products are certified
in internationally recognized certification authority
SGS-FIMKO.
The quality of our products is assured by modern technology, high-quality raw material and well-trained professionals. Company’s quality management system was
declared to be in accordance with of ISO 9001 by LRQA
in 1998. In 2001 Keila Kaabel environmental management system acquired certificate of accordance with
the requirements of ISO 14 001.
Draka Keila Cables is a fast growing manufacturing
company, the key to our success is ability to respond
flexibly to rapidly changing business environment. Draka Keila Cables is open for co-operation possibilities
coming from east as well as west.
Draka and Prysmian joined to form global Prysmian Group
A merger of two large cable corporations formed the Prysmian Group, the world’s largest cable corporation, having
active representations in 50 countries and a total of 90 factories with more than 20,000 employees. Both Draka
and Prysmian are globally strong brands and have strong sides, so the brands will remain in parallel existence and
development in the future. As a result of the merger, our product range is extended because both companies have
numerous unique products that complement the previous product ranges of each other. Also, the availability and
delivery security of products will improve. We can now serve our customers with the know-how and product development of both corporations, and we can better involve our customers in product and service development, taking
into account the local specifics.
2 | Draka Keila Cables
Product Catalogue
General information
Standards
Rated voltage
All conductors and cables in this catalogue are manufactured
according to valid international standards. The cable meets the
requirements of the standards mentioned in the cable description.
The table below gives the common rated voltage for cables according to the international standard IEC 60038.
Special conductors and cables
Also other types of conductors and cables, not included in this catalogue, are available by Draka, as agreed with the client.
Catalogue information
The dimensions and weights are nominal values. Due to continuous product research and development the listed data is subject
to change. Our product development is a continuous process. We
reserve the right to change the data without prior notice.
U0
U
Um
Rated voltage between the conductor and the earth
Rated voltage between conductors
maximum operating voltage in any part of the network,
excluding temporary fluctuations during switching, breaking
and faults
peak value of the impulse withstand voltage between each
conductor and the earth
Up
U0/U
Um
Up
kV
kV
kV
0,6/1
1,2
-
3,6/6
7,2
-
6/10
12
75
12/20
24
125
18/30
36
170
20,3/35 26/45
42
52
198
250
Basic cable data
Minimum bending radius
Maximum pulling force
•
Minimum permissible bending radius during cable pulling are
given in section Basic cable data.
•
•
Values may be reduced by about 30 % in the final installation, if
the cables are bent carefully and evenly only once.
– cables with aluminium conductors . . . . . . . . . . 10 to 15 N/mm2
– cables with copper conductors . . . . . . . . . . . . . 10 to 20 N/mm2
multiplied by the added-up cross section of the inner conductors, but max. value in both cases is 8,500 N.
Maximum permissible pulling tension when pulling by the cable
grip is given in the basic data on each cable type
• Pulling by the eye attached to the conductor
– cables with aluminium conductors . . . . . . . . . . . . . . . 50 N/mm2
– cables with copper conductors . . . . . . . . . . . . . . . . . 100 N/mm2
however not more than about 20,000 N.
•
Product Catalogue
Pulling by the armouring wires 130 N/mm2, multiplied by the
cross section of the armouring
Draka Keila Cables | 3
Basic cable data
Minimum permissible installation temperature
Minimum permissible cable temperature during laying: while laying
power cables, the temperature of cables should not be below the
following values:
The earth fault current increases relatively as much as the capacitance. The charging currents and earth fault currents have been
calculated at a frequency of 50 Hz.
Inductance
•
Plastic insulated power cables < 1 kV
– PVC-sheathed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —15˚C
Inductance given for each cable type is approximate. Assumptions
for the inductance of single core cables:
•
XLPE insulated power cables > 1 kV to < 30 kV
– PVC-sheathed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —5˚C
– PE-sheathed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —20˚C
•
•
XLPE insulated power cables > 30 kV
– PVC-sheathed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —5˚C
– PE-sheathed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . —15˚C
At lower temperature the cables must be adequately warmed up
beforehand. This can be done by storing in a heated area for several
days or by means of special hot air equipment.
Technical data
Resistance
The next pages give for each cable type the maximum direct current resistance (DC-resistance) of the conductors permitted by the
standard at a temperature of +20˚C.
The DC-resistances of metal sheaths and screens are computed
ratings.
The additional losses caused by the skin and proximity effects are
taken into account in the alternating current resistances (AC-resistance) with the following assumptions:
•
•
•
•
Flat formation: the clear space between the cables = the external diameter of cable
Trefoil formation: the cables touch one another
Current ratings
Basic assumptions:
1.
Maximum permissible temperature of the conductor in continuous use:
• PVC insulated 1 kV cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . +70˚C
• XLPE insulated cables (see further details). . . . . . . . . . . . +90˚C
2. Clear space between single core cables:
• flat formation:
external diameter of the cable
• trefoil formation:
cables touch one another
3. Screen circuit:
• open:
screen circuits of the cables are connected together
and earthed at one end only
• closed: screen circuits are connected together at both ends
and earthed at least at one end
4. Aerial installation
• Ambient air temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +25˚C
Frequency 50 Hz
Closed screen circuit
In the trefoil formation the single core cables touch one another,
in the flat formation the clear space between the cables is equal
to the external diameter of the cable.
5. Underground installation
• Ground temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +15˚C
• Depth:
cables below 110 kV . . . . . . . . . . . . . . 0,7 m
110 kV cables. . . . . . . . . . . . . . . . . . . . 1,0 m
• Thermal resistivity of the ground. . . . . . . . . . . . . . . . 1,0 Km/W
The DC-resistance can be converted to match other temperatures,
using the equation:
If XLPE cables are laid underground, it is important to remember that a
continuous conductor temperature of +90˚C may dry up the surrounding
ground, causing an overload on the cable. For this reason, the continuous
conductor temperature should not exceed +65˚C in XLPE insulated underground cables.
Rt = R20 ( 1 + a20 ( t – 20 ))
where Rt resistance at temperature t
R20 resistance at +20˚C
t
temperature of the conductor [˚C]
α20 temperature factor of resistivity [1/˚C]
0,00393 1/˚C with copper conductors
0,00403 1/˚C with aluminium conductors/sheaths
0,00400 1/˚C with lead alloy sheaths
If conditions differ from the above-assumed premises, the maximum
permissible loads must be multiplied by correction factors, which
are given on next pages.
Capacitance
Capacitances are average values with the rated voltage at a temperature of +20˚C and at a frequency of 50 Hz. Especially with
PVC-insulated cables, the capacitance will increase by 40 per cent if
the temperature of the conductor rises from +20˚C to the maximum
permissible continuous conductor temperature.
4 | Draka Keila Cables
Product Catalogue
Basic cable data
Correction factors for underground installation
The effect of several adjacent cables in the ground.
The factor of three core cables and for groups of
three single core cables.
Thermal resistivity in the ground
Clear space between Number of adjacent cables or groups
of single core cables
the cables or
between the groups
of single core cables
mm
2
3
4
5
6
8
10
0
0,79
0,69
0,63
0,58
0,55
0,50
0,46
70
0,85
0,75
0,68
0,64
0,60
0,55
0,53
250
0,87
0,79
0,75
0,72
0,69
0,66
0,64
Thermal resistivity 0,7
in the ground Km/W
1,0
1,2
1,5
2,0
2,5
3,0
Correction factor
1,00
0,92
0,85
0,75
0,69
0,63
1,10
Thermal resistivity in different types of soil:
– dry sand (moisture content 0%). . . . . . . . . . . . . . . . . . . . . 3.0 Km/W
– dry gravel and clay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Km/W
– semi-dry gravel, bog earth and sand (moisture 10%) . . . 1.2 Km/W
– semi-dry clay and damp gravel. . . . . . . . . . . . . . . . . . . . . . . 1.0 Km/W
– damp clay and sand (moisture content 25 %). . . . . . . . . . 0.7 Km/W
Laying depth
Cable
Laying depth, m
0,50–0,70
0,71–0,90
0,91–1,10
1,11–1,30
1,31–1,50
0,61/1,0 kV
1,00
0,97
0,95
0,93
0,92
6/10–18/30 kV
1,00
0,99
0,98
0,96
0,95
Ground temperature
Conductor temperature
Ground temperature,˚C
˚C
-5
0
5
10
15
20
25
30
35
40
45
90
1,13
1,10
1,06
1,03
1,00
0,96
0,93
0,89
0,86
0,82
0,77
80
1,14
1,11
1,07
1,04
1,00
0,96
0,92
0,88
0,83
0,78
0,73
70
1,17
1,13
1,09
1,04
1,00
0,95
0,90
0,85
0,80
0,73
0,67
65
1,18
1,14
1,10
1,05
1,00
0,95
0,89
0,84
0,77
0,71
0,63
Underground installation in PE or PVC tubes, with one three core cable or three single core cables. The cables are loaded at the same time. The
tubes lie side by side. If the correction factors of this table are applied, the factors in the topmost table are not used
Clear distance of the tubes
Number of adjacent tubes
mm
1
2
3
4
5
6
8
10
0
0,80
0,75
0,65
0,60
0,60
0,55
0,55
0,50
70
-
0,75
0,70
0,65
0,60
0,60
0,55
0,55
250
-
0,75
0,70
0,70
0,70
0,65
0,65
0,65
The tubes lie side by side. If the
correction factors of this table
applied, the factors in the topmost table are not used.
The effect of cable cover slabs and troughs
Type of covering
Correction factor
A concrete or brick slab more than 10 cm above the cable in well-compacted sandy ground
1,00
Bricks all around the cable, gaps sealed up tightly with sand
0,90
A concrete trough on the cable, compacted sand between the trough and the cable
0,90
A concrete or plastic trough on the cable, loose sand filler between the cable and the trough
0,80
Product Catalogue
Draka Keila Cables | 5
Basic cable data
Ambient air temperature
Conductor temperature,˚C
Ambient air temperature,˚C
˚C
10
15
20
25
30
35
40
45
50
55
90
1,12
1,08
1,04
1,00
0,95
0,90
0,85
0,80
0,74
0,68
80
1,14
1,09
1,05
1,00
0,95
0,89
0,48
0,77
0,69
0,61
70
1,18
1,12
1,06
1,00
0,95
0,86
0,79
0,71
0,62
0,52
65
1,20
1,14
1,07
1,00
0,95
0,85
0,77
0,68
0,57
0,45
CORRECTION FACTORS FOR AERIAL INSTALLATION OR FOR INSTALLATION TYPE B
Cables in air = the same cooling conditions as when freely in air
Installation type A
INSTALLATION TYPE B:
The cable is laid on the surface or so that between the cable and the
surface of the covering material the thermal transmission factor is
11–50 W/˚C m2.
The cable is laid on the surface or so that between the cable and the
surface of the covering material the thermal trans¬mission factor
is K>50 W/˚C m2.
Installation type B includes one of the following:
Installation type B includes one of the following:
– surface installation
– installation on a cable rack with short lead-through
– disaccording to installation type B
–
–
–
–
surface installation (also in a tube) with short lead-through
installation on a cable rack with short lead-through
sunk installation in stone structures (concrete, brick, etc.)
installation in a riser shaft or in a cable duct
The effect of grouping in aerial installation on the loading of Multicore alternating current cables and on single core direct current cables
The data is valid, provided that the ambient temperature does not rise significantly in result of the increasing heat by dissipation in the cable.
Arrangement of the cables
Clear space = cable diameter (d);
distance from the wall ≥ 20 mm
Number of adjacent cables
1
On the floor or on the ceiling
Correction factor
2
3
6
The cables touch one another and the wall
9
Drawing
1
20 mm
2
3
6
9
Drawing
Correction factor
d
Unperforated trays
Ladder supports,
cleats, etc.
0,95
0,90
0,88
0,85
0,84
0,95
0,90
0,88
0,86
1,00
1,00
1,00
1,00
0,90
0,85
0,83
0,81
0,98
0,95
0,94
0,93
0,88
0,83
0,81
0,79
0,96
0,93
0,92
0,90
0,85
0,81
0,79
0,77
0,93
0,90
0,89
0,87
0,84
0,80
0,78
0,76
0,92
0,89
0,88
0,86
0,90
0,84
0,80
0,75
0,73
0,95
0,95
0,95
0,95
0,95
0,95
0,95
0,95
0,84
0,80
0,78
0,76
0,84
0,80
0,78
0,76
0,80
0,75
0,74
0,72
0,80
0,76
0,74
0,72
0,75
0,71
0,70
0,68
0,75
0,71
0,70
0,68
0,73
0,69
0,68
0,66
0,73
0,69
0,68
0,66
No, of racks
1
2
3
6
1
2
3
6
0,3 m
d
d
20 mm
0,3 m
d
0,3 m
0,3 m
d
20 mm
Number of overlying cables
1
2
3
6
9
1
2
3
6
9
On racks or on the wall
1,00
0,93
0,90
0,87
0,86
0,95
0,78
0,73
0,68
0,66
d
d
20 mm
Installation with no need to
reduce the load current
Unrestricted number of overlying cables
2d
d
20 mm
6 | Draka Keila Cables
Unrestricted number of adjacent cables
0,3 m
2d
20 mm
d
Product Catalogue
Basic cable data
The effect of grouping in aerial installation on the loading of single core alternating current cables
The data is valid, provided that the ambient temperature does not rise significantly in result of the increasing heat by dissipation in the cable.
Arrangement of the cables
Flat formation, clear space = cable diameter (d);
distance from the wall >20 mm
Cables touch one another and the wall
Number of adjacent systems
1
1
On the floor or on the ceiling
Correction factor
0,92
Unperforated trays
2
0,89
3
Drawing
20 mm
d
d
0,88
No, of racks
d
3
Correction factor
0,95
20 mm
2
0,90
20 mm
20 mm
1
0,92
0,89
0,88
0,95
0,80
0,73
2
0,87
0,84
0,83
0,95
0,76
0,69
3
0,84
0,82
0,81
0,95
0,74
0,68
6
0,82
0,80
0,79
0,95
0,72
0,66
1
1,00
0,97
0,96
1,00
0,98
0,96
2
0,97
0,94
0,93
1,00
0,95
0,93
3
0,96
0,93
0,92
1,00
0,94
0,92
6
0,94
0,91
0,90
1,00
0,93
0,90
Number of overlying systems
1
2
3
1
2
3
On racks or on the wall
0,94
0,91
0,89
0,89
0,88
0,84
Ladder supports,
cleats, etc.
20 mm
d
0,3 m
20 mm
d
Installation with no need to the
load current
d
2d
2d
0,88
d
0,3 m
Drawing
2d
0,3 m
20 mm
2d
2d
0,3 m
2d
d
With a longer distance, there are more reduce losses in the metal sheath and in the armouring, while
cooling improves. Each case must be calculated separately.
2d
20 mm
4d
2d
0,3 m
Short circuit current capacity
Thermal stress
Dynamic stress
Taking into account the mechanical and electrical strength of the
insulation, thermal stress by a short circuit is restricted by setting
the maximum final conductor temperatures in a short circuit:
Short circuit currents cause a mechanical load on the cable as well
as on the accessories.
– XLPE-insulated cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +250˚C
– PVC-insulated 1 kV cables
≤ 300 mm2. . . . . . . . . . . . . . . . +160˚C
> 300 mm2. . . . . . . . . . . . . . . . +140˚C
The given values for maximum permissible short circuit currents
in cable data have been calculated assuming the initial conductor
temperature to be the maximum operating temperature in continuous use.
The listed short circuit currents for duration of one second indicate
the thermal capacity of the conductor. The maximum permissible
thermal short circuit current for duration of 0.2 to 5 seconds can be
computed by the equation:
The dynamic short circuit stress is much greater near the high voltage network and near large power plants than farther out in the
network. That is why the dynamic capacity of the accessories as well
as the cable fittings must be checked. This is especially important
with high power systems and with several parallel cables in aerial
installation.
Most important in a short circuit is the peak value of current, which
is 2.5 times the short circuit current. To minimize dynamic stress,
the installation must be made using the right accessories and the
right technique.
Ιt=Ι1s/√t
where
l1s = 1 s thermal short circuit current [kA]
t = duration of the short circuit [s]
Product Catalogue
Draka Keila Cables | 7
Power cables
ACSR
Aluminium conductor steel reinforced
Application
Temperature range
Bare conductor for overhead power transmission.
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . .80˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . 200˚C
Standards
SFS 5701
IEC 61089
EN 50182
8 | Draka Keila Cables
Construction
A conductor consisting aluminium and galvanized steel
wires, built up in concentric layers. The centre wires are
steel and outer layer aluminium wires.
Product Catalogue
Power cables
ACSR
Aluminium conductor steel reinforced
Basic data
Product name according to IEC
EAN code
Construction data
Aluminium
No of wires
Diameter of wire
Cross section
Weight (5)
Steel
No of wires
Diameter of wire
Cross section
Weight (5)
Complete conductor
No of wires
Diameter of conductor
Cross section
Weight (5)
Delivery data
Standard delivery length
Standard delivery drum
Total weight (1)
Mechanical data (2)
Minimum tensile strength of the conductor
Initial modulus of elasticity of conductor
Final modulus of elasticity of conductor
Coefficient of linear expansion of conductor
Electrical data (2)
Max. DC resistance of conductor (20˚C) (3) (5)
Current ratings
In air
Short circuit currents (2)
Max. permissible short circuit current for 1 sec. (4)
ACSR 34/6
SPARROW
34-A1/S1A-6/1
01 202 02-2
ACSR 42/25
SAVO
42-A1/S1A-12/7
01 202 28-2
ACSR 54/9
RAVEN
54-A1/S1A-6/1
01 202 05-3
ACSR 85/14
PIGEON
85-A1/S1A-6/1
01 202 09-1
ACSR 89/52
DOTTEREL
89-A1/S1A-12/7
01 202 31-2
6
2,68
33,8
92,9
1
2,68
5,64
43,9
7
8,04
39,5
137
12
2,12
42,4
117
7
2,12
24,7
193
19
10,6
67,1
310
6
3,37
53,5
147
1
3,37
8,92
69,4
7
10,1
62,4
216
6
4,25
85,1
234,0
1
4,25
14,2
110,0
7
12,8
99,3
344,0
6
3,08
89,4
247,0
7
3,08
52,2
408,0
19
15,4
142
654,0
kg
2500
K11
390
2500
K12
860
2200
K11
560
2000
K12
770
2500
K16
1790
kN
N/mm2
N/mm2
1/K
12,2
64000
78000
19,2 x 10–6
13,52
93000
102000
15,6 x 10–6
17,11
64000
78000
19,2 x 10–6
24,13
64000
78000
19,2 x 10–6
33,37
93000
102000
15,6 x 10–6
Ω/km
0,848
0,682
0,536
0,337
0,323
A
210
250
280
360
400
kA
3,7
5,4
5,8
9,2
11,4
64 100+
ACSR 152/25
OSTRICH
152-A1/S1A-26/7
01 202 15-2
ACSR 242/39
HAWK
242-A1/S1A-26/7
01 202 18-3
ACSR 305/39
DUCK
305-A1/S1A-54/7
01 202 21-3
ACSR 402/52
CONDOR
402-AL1/52-ST1A
01 054 07-2
ACSR 565/72
FINCH
565-A1/S1A-54/19
01 202 24-4
26
2,73
152
420
7
2,12
24,7
193
33
17,3
177
613
26
3,44
242
668
7
2,68
39,5
309
33
21,8
281
976
54
2,68
305
842
7
2,68
39,5
309
61
24,1
344
1151
54
3,08
402,3
1110,5
7
3,08
52,2
410
61
27,7
454,5
1520,5
54
3,65
565
1562
19
2,19
71,6
561
73
32,9
637
2123
kg
2500
K18
1760
2500
K20
2780
2200
K22
3290
2300
K22
3908
1400
K22
3380
kN
N/mm2
N/mm2
1/K
54,8
61000
76000
19,2 x 10–6
84,9
61000
76000
19,2 x 10–6
96,8
50000
67000
19,3 x 10–6
123,75
51000
68000
19,3 x 10–6
174
46000
63000
19,3 x 10–6
Ω/km
0,190
0,120
0,0949
0,0719
0,0512
A
550
745
845
1000
1250
kA
16,5
26,1
32,5
43,7
60,1
64 100+
mm
mm2
kg/km
mm
mm2
kg/km
mm
mm2
kg/km
m
Basic data
Product name according to IEC
EAN code
Construction data
Aluminium
No of wires
Diameter of wire
Cross section
Weight (5)
Steel
No of wires
Diameter of wire
Cross section
Weight (5)
Complete conductor
No of wires
Diameter of conductor
Cross section
Weight (5)
Delivery data
Standard delivery length
Standard delivery drum
Total weight (1)
Mechanical data (2)
Minimum tensile strength of the conductor
Initial modulus of elasticity of conductor
Final modulus of elasticity of conductor
Coefficient of linear expansion of conductor
Electrical data (2)
Maximum DC resistance of conductor (20˚C) (3) (5)
Current ratings
In air
Short circuit currents (2)
Maximum permissible short circuit current for 1 sec. (4)
mm
mm2
kg/km
mm
mm2
kg/km
mm
mm2
kg/km
m
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Calculated with steel core.
4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C.
5) Nominal value according to standard.
Product Catalogue
Draka Keila Cables | 9
Power cables
HK
Copper conductor
Application
Temperature range
Grounding wire.
Highest permissible conductor temperature
short circuit (duration up to 5 s) . . . . . . . . . . . . . . 200˚C
Standard
Construction
IEC 60228 Class 2
Concentric stranded soft copper conductor.
Certificate/approval
CE, RoHS
Product name
EAN code
Customs code
Constructional data
Number of wires
Diameter of wire
Diameter of conductor
Cross section
Weight of conductor (1)
Delivery data
Standard delivery length
Standard delivery drum
Weight (1) cable+drum
Electrical data (2)
Max DC resistance of conductor 20˚C
Short circuit currents (2)
Max permissible short circuit current for 1
second (3)
HK
16/7x1.68
coil/25 m
64 100+ 01 050 05-0
74.13.00.91
HK
16/7x1.68
coil/50 m
01 050 06-7
74.13.00.91
HK
16/7x1.68
coil/100 m
01 050 07-4
74.13.00.91
HK
25/7x2.12
coil/100 m
01 050 25-8
74.13.00.91
HK
HK 16/7x1.68
drum
01 550 07-9
74.13.00.91
HK
HK 25/7x2.12
drum
01 050 08-1
74.13.00.91
7
1,68
5,04
15,5
140
7
1,68
5,04
15,5
140
7
1,68
5,04
15,5
140
7
2,12
6,36
24,7
222
7
1,68
5,04
15,5
140
7
2,12
6,36
24,7
222
kg
25
coil
3,5
50
coil
7
100
coil
14
50
coil
11
500
K6
82
500
K6
123
Ω/km
1,15
1,15
1,15
0,727
1,15
0,727
kA
2,3
2,3
2,3
3,8
2,3
3,8
mm
mm2
kg/km
m
Product name
EAN code
Customs code
Constructional data
Number of wires
Diameter of wire
Diameter of conductor
Cross section
Weight of conductor (1)
Delivery data
Standard delivery length
Standard delivery drum
Weight (1) cable+drum
Electrical data (2)
Max DC resistance of conductor 20˚C
Short circuit currents (2)
Max permissible short circuit current for 1 second (3)
HK
35/7x2.50
drum
64 100+ 01 050 09-8
74.13.00.91
HK
50/19x1.77
drum
01 050 10-4
74.13.00.91
HK
70/19x2.12
drum
01 050 11-1
74.13.00.91
HK
95/19x2.50
drum
01 050 12-8
74.13.00.91
HK
120/37x2.01
drum
01 050 13-5
74.13.00.91
7
2,5
7,5
34,4
309
19
1,77
8,85
46,8
422
19
2,12
10,6
67,1
606
19
2,5
12,5
93,3
843
37
2,01
14,1
117
1062
kg
1000
K7
329
1000
K7
642
1000
K9
640
1000
K11
898
1000
K11
1152
Ω/km
0,524
0,387
0,268
0,193
0,153
kA
5,3
7,2
10,3
14,3
18
mm
mm
mm2
kg/km
m
1) Approximate value
2) See the basic assumptions at general information of products.
3) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C.
10 | Draka Keila Cables
Product Catalogue
Power cables
AS
Aluminium conductor steel reinforced AS
Application
Temperature range
Bare conductor.
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . 80 ˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . 200 ˚C
Standard
GOST 889-80
Construction
Round, stranded aluminium steel reinforced conductor.
Basic data
EAN code
AS 25
01 203 25
AS 35
01 203 35
AS 50
01 203 50
AS 70
01 203 70
AS 95
01 203 95
6
2,30
24,9
68,3
1
2,30
4,15
32,3
7
6,9
29,05
100,7
6
2,80
36,9
101,3
1
2,80
6,15
47,9
7
8,4
43,05
149,2
6
3,20
48,2
132,3
1
3,20
8,04
62,6
7
9,6
56,24
194,9
6
3,80
68,0
188,0
1
3,80
11,3
88,0
7
11,4
79,3
276,0
6
4,50
95,4
261,0
1
4,50
15,9
124,0
7
13,5
111,3
385,0
kg
4000
K9
430
4000
K11
645
3500
K11
740
2500
K11
745
2500
K14
1080
kN
N/mm2
N/mm2
1/K
9,13
64000
78000
19,2 x 10–6
13,52
64000
78000
19,2 x 10–6
17,11
64000
78000
19,2 x 10–6
24,13
64000
78000
19,2 x 10–6
33,37
64000
78000
19,2 x 10–6
Ω/km
1,1521
0,7774
0,5951
0,4218
0,3007
A
142
175
210
265
330
kA
2,7
4,0
5,3
7,5
10,5
64 100+
Construction data
Aluminium
No of wires
Steel
Conductor
Diameter over wire
Cross section
Weight (5)
No of wires
Diameter over wire
Cross section
Weight (5)
No of wires
Diameter over conductor
Cross section
Weight (5)
Delivery data
Standard delivery length
Drum
Total weight (1)
Mechanical data (2)
Minimum tensile strength of the conductor
Initial modulus of elasticity of conductor
Final modulus of elasticity of conductor
Coefficient of linear expansion of conductor
Electrical data (2)
Maximum DC resistance of conductor (20 ˚C) (3) (5)
Current ratings
In air
Short circuit currents (2)
Max. permissible short circuit current for 1 second (4)
mm
mm2
kg/km
mm
mm2
kg/km
mm
mm2
kg/km
m
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Calculated with steel.
4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C.
5) Standard based value.
Product Catalogue
Draka Keila Cables | 11
Power cables
A
Bare conductor A
Application
Bare conductor.
Standard
GOST 889-80
Temperature range
Highest permissible conductor temperature:.
– in continuous operation. . . . . . . . . . . . . . . . . . . . . . . 80 ˚C
– in a short circuit (duration up to 5 s). . . . . . . . . . 200 ˚C
Construction
Round, stranded aluminium conductor.
Basic data
EAN code
Construction data
No of wires
Diameter over wire
Cross section
Weight (5)
Delivery data
Standard delivery length
Drum
Total weight (1)
Mechanical data (2)
Minimum tensile strength of the conductor
Initial modulus of elasticity of conductor
Final modulus of elasticity of conductor
Coefficient of linear expansion of conductor
Electrical data (2)
Maximum DC resistance of conductor (20˚C) (3) (5)
Current ratings
In air
Short circuit currents (2)
Maximum permissible short circuit current for 1 second (4)
A 25
64 100+ 01 209 25
A 35
01 209 35
A 50
01 209 50
A 70
01 209 70
A 95
01 209 95
7
2,13
24,9
68
7
2,50
34,3
94
7
3,00
49,5
135
7
3,55
69,3
189
7
4,10
92,4
252
kg
4000
K9
300
4000
K11
425
3500
K11
520
2500
K11
520
2500
K12
720
kN
N/mm2
N/mm2
1/K
4,50
41000
60000
23,0 x 10–6
5,91
41000
60000
23,0 x 10–6
8,19
41000
60000
23,0 x 10–6
11,28
41000
60000
23,0 x 10–6
14,78
41000
60000
23,0 x 10–6
Ω/km
1,1498
0,8347
0,5784
0,4131
0,3114
A
136
170
215
265
320
kA
2,5
3,4
5,0
7,0
9,3
mm
mm2
kg/km
m
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Calculated with steel.
4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C.
5) Standard based value.
12 | Draka Keila Cables
Product Catalogue
Power cables
AXMK-PLUS and XMK-PLUS 1-core
1 kV power cable with XLPE insulated aluminium conductors and
halogen-free outersheath
Application
Temperature range
Designed for replacement of AXPK and AXPK-PE. The
outer sheath is self-extinguishing and halogen-free.
Cable is mechanically as strong as PE. For fixed installation indoors and outdoors, perfect for ploughing down.
Suitable for cable ducts and house connections
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . .250˚C
Lowest recommended handling temperature . . . . . –20˚C
Construction
Standards
Conductor . . AXMK – round, stranded and compacted
aluminium conductor
XMK – round, stranded and compacted
copper conductor
Insulation . . . black XLPE compound
Sheath . . . . . black halogen-free self-extinguishing PE
compound; insulation and sheath are
UV (1) resistible and they don't need extra
protection against sunlight.
SFS 4879, HD 603-5D S1, IEC 60502-1, IEC 60332-1 Cat. B
Certificate/approval
EEI, FI, CE
Rated voltage
U0/U = 0,6/1 kV, Um = 1,2 kV
Marking
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking.
Basic data
AXMK
1x300 1 kV
64 100+ 06 261 02-4
EAN code
Construction data
AXMK
1x500 1 kV
06 210 27-5
AXMK
1x800 1 kV
06 261 05-5
XMK
1x300 1 kV
06 211 77-7
mm
kg/km
kg/km
kg/km
29
795
1150
36
1312
1850
44
2160
2950
29
2620
3050
Standard delivery length
Drum
m
cable + drum
Total weight (2)
Mechanical data (3)
Minimum permissible bending radius during laying
kg
1000
K18
1380
500
K18
1155
500
K20
1810
1000
K16
3240
m
m
kN
kN
0,44
0,31
4,5
15,0
0,54
0,38
7,0
20,0
0,68
0,48
8,5
20,0
0,44
0,31
4,5
20,0
Ω/km
0,100
0,0605
0,0367
0,0601
A
A
A
A
525
460
690
560
873
636
1000
830
1300
1050
665
580
845
735
kA
28,3
47,0
75,6
42,8
External cable diameter (2)
Weight (2)
aluminium
copper
cable
Delivery data
Minimum permissible bending radius at final installation (4)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (3)
conductor 20˚C
Maximum DC resistance of conductor
Current ratings (3)
Flat formation (in earth)
conductor 70˚C
Trefoil formation (in earth)
conductor 70˚C
Flat formation (in air)
conductor 90˚C
Trefoil formation (in air)
conductor 90˚C
Short circuit currents (3)
Maximum permissible short circuit current for 1 second (5)
1)
2)
3)
4)
5)
Product Catalogue
UV – ultraviolet radiation
Approximate value.
See the basic assumptions at general information of products.
Final installation with careful single bending.
Initial temperature of conductor before short circuit 90˚C, final temperature of conductor after short circuit 250˚C.
Draka Keila Cables | 13
Power cables
AXPK-PLUS
1 kV power cable with XLPE insulated aluminium conductors and
halogen-free outersheath
Application
Construction
Designed for replacement of AXPK and AXPK-PE. The
outer sheath is self-extinguishing and halogen-free.
Cable is mechanically as strong as PE sheathed cable.
For fixed installation indoors and outdoors, perfect for
ploughing down. Suitable for cable ducts and house
connections.
FI, CE
Conductor . . . . . . . 16 mm2 – solid round aluminium
conductor;
25–300 mm2 – stranded, compacted
and annealed sector shaped aluminium conductor
Insulation . . . . . . . black XLPE compound
Laying up . . . . . . . four insulated conductors stranded
together
Sheath . . . . . . . . . . black halogen-free self-extinguishing
PE compound;
insulation and sheath are UV (1)
resistible and they don't need extra
protection against sunlight.
Rated voltage
Identification of cores
U0/U = 0,6/1 kV
Um = 1,2 kV
Phase conductors . . brown, black, grey
PEN conductor . . . yellow-green
Temperature range
Marking
Highest permissible conductor temperature:
- in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C
- in a short circuit (duration up to 5 s) . . . . . . . . . . 250˚C
Lowest recommended temp. during laying . . . . . . . –20˚C
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking.
Standards
SFS 4879, HD 603-5D S1, IEC 60502-1,
IEC 60332-1 Cat. B, HD 308 S2:2002
Certificate/approval
1)
14 | Draka Keila Cables
UV – ultraviolet radiation
Product Catalogue
Power cables
AXPK-PLUS
1 kV power cable with XLPE insulated aluminium conductors and
halogen-free outersheath
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
aluminium
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
conductor 90˚C
Short circuit currents (2)
Maximum permissible short circuit current for 1 second (4)
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
aluminium
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
conductor 90˚C
Short circuit currents (2)
Maximum permissible short circuit current for 1 second (4)
4G16
64 100+ 06 210 07-7
4G25
06 210 08-4
4G35
06 210 09-1
4G50
06 210 10-7
4G70
06 210 11-4
4G95
06 210 12-1
mm
kg/km
kg/km
20
165
380
21
265
500
23
365
670
27
495
830
30
720
1170
34
995
1500
m
kg
1000
K12
470
1000
K14
615
1000
K16
865
1000
K16
1025
1000
K18
1400
1000
K20
1840
m
m
kN
kN
0,24
0,17
0,9
3,2
0,26
0,19
1,5
5,0
0,28
0,20
2,1
7,0
0,31
0,23
3,0
10,0
0,36
0,26
4,2
14,0
0,41
0,29
5,7
19,0
Ω/km
Ω/km
1,91
2,3
1,20
1,5
0,868
1,0
0,641
0,77
0,443
0,53
0,320
0,39
A
A
A
78
64
75
100
83
105
125
105
130
150
125
165
185
155
205
220
190
245
kA
1,5
2,3
3,3
4,7
6,6
8,9
4G120
64 100+ 06 21013-8
4G150
06 210 14-5
4G185
06 210 15-2
4G240
6 210 16-9
4G300
mm
kg/km
kg/km
38
1260
1900
42
1550
2300
47
1950
2800
53
2550
3700
58
3190
4600
m
kg
1000
K22
2310
500
K20
1490
500
K20
1740
500
K22
2260
500
K24
2750
m
m
kN
kN
0,46
0,33
7,2
20,0
0,51
0,36
8,5
20,0
0,57
0,40
8,5
20,0
0,64
0,45
8,5
20,0
0,70
0,49
8,5
20,0
Ω/km
Ω/km
0,253
0,31
0,206
0,25
0,164
0,20
0,125
0,16
0,100
0,13
A
A
A
255
220
280
290
250
320
330
285
365
375
330
430
430
380
480
kA
11,3
14,1
17,4
22,6
28,3
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 90˚C, final temperature of conductor after short circuit 250˚C.
Product Catalogue
Draka Keila Cables | 15
Power cables
AXPK
1 kV power cable with XLPE insulated aluminium conductors
Application
Construction
Fixed indoor, outdoor and underground installations.
Conductor . . . . . . . 16 mm2 – solid round aluminium
conductor;
25–300 mm2 – stranded, compacted
and annealed sector shaped aluminium conductor
Insulation . . . . . . . black XLPE compound
Laying up . . . . . . . four insulated conductors stranded
together
Sheath . . . . . . . . . . black PVC;
plastics are UV (1) resistible and they
don't need extra protection against
sunlight.
Standards
SFS 4879, HD 603-5D S1, IEC 60502-1,
IEC 60332-1 Cat. B, HD 308 S2:2002
Certificate/approval
EEI, FI, CE
Rated voltage
U0/U = 0,6/1 kV
Um = 1,2 kV
Temperature range
Highest permissible conductor temperature:
- in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C
- in a short circuit (duration up to 5 s) . . . . . . . . . . 250˚C
Lowest recommended temp. during laying . . . . . . . –15˚C
1)
16 | Draka Keila Cables
Identification of cores
Phase conductors . . brown, black, grey
PEN conductor . . . yellow-green
Marking
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking.
UV – ultraviolet radiation
Product Catalogue
Power cables
AXPK
1 kV power cable with XLPE insulated aluminium conductors
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
aluminium
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
conductor 90˚C
Short circuit currents (2)
Maximum permissible short circuit current for 1 second (4)
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
aluminium
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
conductor 90˚C
Short circuit currents (2)
Maximum permissible short circuit current for 1 second (4)
4G16
64 100+ 06 210 07-7
4G25
06 210 08-4
4G35
06 210 09-1
4G50
06 210 10-7
4G70
06 210 11-4
4G95
06 210 12-1
mm
kg/km
kg/km
20
165
380
21
265
500
23
365
670
27
495
830
30
720
1170
34
995
1500
m
kg
1000
K12
470
1000
K14
615
1000
K16
865
1000
K16
1025
1000
K18
1400
1000
K20
1840
m
m
kN
kN
0,24
0,17
0,9
3,2
0,26
0,19
1,5
5,0
0,28
0,20
2,1
7,0
0,31
0,23
3,0
10,0
0,36
0,26
4,2
14,0
0,41
0,29
5,7
19,0
Ω/km
Ω/km
1,91
2,3
1,20
1,5
0,868
1,0
0,641
0,77
0,443
0,53
0,320
0,39
A
A
A
78
64
75
100
83
105
125
105
130
150
125
165
185
155
205
220
190
245
kA
1,5
2,3
3,3
4,7
6,6
8,9
4G120
64 100+ 06 21013-8
4G150
06 210 14-5
4G185
06 210 15-2
4G240
6 210 16-9
4G300
mm
kg/km
kg/km
38
1260
1900
42
1550
2300
47
1950
2800
53
2550
3700
58
3190
4600
m
kg
1000
K22
2310
500
K20
1490
500
K20
1740
500
K22
2260
500
K24
2750
m
m
kN
kN
0,46
0,33
7,2
20,0
0,51
0,36
8,5
20,0
0,57
0,40
8,5
20,0
0,64
0,45
8,5
20,0
0,70
0,49
8,5
20,0
Ω/km
Ω/km
0,253
0,31
0,206
0,25
0,164
0,20
0,125
0,16
0,100
0,13
A
A
A
255
220
280
290
250
320
330
285
365
375
330
430
430
380
480
kA
11,3
14,1
17,4
22,6
28,3
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 90˚C, final temperature of conductor after short circuit 250˚C.
Product Catalogue
Draka Keila Cables | 17
Power cables
EMC-Line 1 kV (IFSI)
Halogen-free EMC compatible power cable with aluminium conductor
Application
Approvals
Power cable with rated voltage up to 1 kV. Halogen-free
cable for indoor and outdoor use, to secure areas from
heavy smoke and corrosive gases in case of fire. Improved EMC screen according to EMC directive. National
regulations for electrical installations must be followed.
NEMKO CE-marked, acc. to LVD(1)
Max conductor temperature. . . . . . . . . . . . . . . . . . . . 9O˚C
Rated voltage U0/U . . . . . . . . . . . . . . . . . . . . . . . . . 0,6/1 kV
CENELEC designation . . . . . . . . . . . . . . . . N1ZCZ1-AR (AS)
Standards applied
HD 604-5D Construction
IEC 60502-1 Insulation
IEC 60332-3C Flame Retardancy
IEC 60754-1 and 2 Halogen-free
IEC 61034 Low Smoke
No. of cores and
conductor area
mm2
3x25/10
3 x 50/16
3 x 95/35
3 x 150/50
3 x 240/70
4 x 25/10
4 x 50/16
4 x 95/35
4 x 150/50
4 x 240/70
Construction
Conductor . . . . . . . . . . . stranded aluminium
Insulation . . . . . . . . . . . . cross-linked halogen-free polymer
Bedding/tape . . . . . . . . halogen-free
Concentric conductor . . (PE/PEN conductor) copperfoil
with overlap and concentric
screen of copper wires
Outer sheath . . . . . . . . . halogen-free polymer
Colour . . . . . . . . . . . . . . . black
Mode of packing . . . . . . drum
Marking
Printed on outer sheath, designation and dimension.
Meter marking and year of production.
Conductor type (2)
Art. No.
AFR
AFV
AFV
AFV
AFV
AFR
AFV
AFV
AFV
AFV
478130
478170
478210
478553
478563
478135
478175
478215
478556
478566
Outer diameter
approx.
mm
23
26
34
40
49
25
29
36
45
55
Approx. weight
kg/km
550
850
1590
2290
3520
660
1050
1920
2820
4400
Normal delivery
length
m
500
500
500
500
400
500
500
500
500
400
1) LVD – Low Voltage Directive
2) ER – Solid round
FR – Stranded round
FV – Stranded sector shaped
18 | Draka Keila Cables
Product Catalogue
Power cables
EMC-Line 1 kV (IFSI)
Halogen-free EMC compatible power cable with copper conductor
Application
Approvals
Power cable with rated voltage up to 1 kV. Halogen-free
cable for indoor and outdoor use, to secure areas from
heavy smoke and corrosive gases in case of fire. Improved EMC screen according to EMC directive. National
regulations for electrical installations must be followed.
NEMKO, CE-marking, acc. to LVD (1)
Max conductor temp. . . . . . . . . . . . . . . . . . . . . . . . . . . 9O˚C
Rated voltage U0/U . . . . . . . . . . . . . . . . . . . . . . . . . 0,6/1 kV
CENELEC designation
N1ZA5Z1-U, N1ZCZ1-U (R-S)
Standards applied
HD 604-5D Construction
IEC 60502-1 Insulation
IEC 60332-3C Flame Retardancy
IEC 60754-1 and 2 Halogen-free
IEC 61034 Low Smoke
Construction
Conductor . . . . . . . . . . . solid or stranded copper
Insulation . . . . . . . . . . . . cross-linked Halogen-free polymer
Bedding/tape . . . . . . . . halogen-free
Concentric conductor . . (PE/PEN conductor) 1,5–2,5 mm2
have aluminium tape
with drain wire;
>4 mm2 have copperfoil with
overlap and concentric screen
of copper wires
Outer sheath . . . . . . . . . halogen-free polymer
Colour . . . . . . . . . . . . . . . black
Mode of packing . . . . . . drum
Marking
Printed on outer sheath, designation and dimension.
Meter marking and year of production.
No. of cores
and conductor area
mm2
2 x 1,5/1,5
2 x 2,5/2,5
2 x 4/4
2 x 6/6
2 x 10/10
2 x 16/16
3 x 1,5/1,5
3 x 2,5/2,5
3 x 4/4
3 x 6/6
3 x 10/10
3 x 16/16
3 x 25/16
3 x 35/16
3 x 50/25
3 x 70/35
3 x 95/50
3 x 120/70
Conductor Art. No.
type (2)
ER
ER
ER
ER
FR
FR
ER
ER
ER
ER
FR
FR
FR
FV
FV
FV
FV
FV
422005
422025
422045
422065
422085
422105
422010
422030
422050
422070
422090
422110
422130
422150
422170
422190
422210
422230
Outer
diameter
approx.
mm
11
12
13
14
18
20
11
12
13
14
18
21
24
24
26
30
33
38
Approx.
weight
kg/km
170
210
210
270
440
640
180
230
250
330
550
820
1110
1390
1800
2520
3450
4290
No. of cores
and conductor area
mm2
3 x 150/70
3 x 185/95
3 x 240/120
4 x 1,5/1,5
4 x 2,5/2,5
4 x 4/4
4 x 6/6
4 x 10/10
4 x 25/16
4 x 35/16
4 x 50/25
4 x 70/35
4 x 95/50
4 x 120/70
4 x 150/70
4 x 185/95
4 x 240/120
Conductor Art. No.
type (2)
FV
FV
FV
ER
ER
ER
ER
FR
FR
FV
FV
FV
FV
FV
FV
FV
FV
422250
422290
422015
422035
422055
422075
422095
422135
422175
422195
422215
422235
422255
422275
422295
Outer
diameter
approx.
mm
40
48
53
12
13
14
16
20
26
28
28
35
39
42
46
53
59
Approx.
weight
kg/km
5200
7200
8500
210
280
300
400
660
1370
1850
2270
3200
4380
5430
6590
8750
10900
1) LVD – Low Voltage Directive
2) ER – Solid round
FR – Stranded round
FV – Stranded sector shaped
Product Catalogue
Draka Keila Cables | 19
Power cables
AMCMK 3 1/2-core
1 kV power cable with PVC insulated aluminium conductors
Application
Fire resistance class
Fixed indoor, outdoor and underground installations.
25 – 300 mm2 . . . . IEC 60332-3 category B
16 mm2 . . . . . . . . . . IEC 60332-1
Standards
SFS 4880
HD 603-3F S1
IEC 60502-1
IEC 60332-3 category B
Certificate/approval
FI, CE
Rated voltage
U0/U = 0,6/1 kV
Um = 1,2 kV
Temperature range
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . 160˚C
Lowest recommended temperature during laying . . –15˚C
20 | Draka Keila Cables
Construction
Conductor . . . . . . . 16 mm2 – solid round annealed aluminium conductor;
25–300 mm2 – stranded, compacted
and annealed sector shaped aluminium conductor
Insulation . . . . . . . . PVC
Laying up . . . . . . . . three insulated phase conductors
stranded together
PE conductor . . . . contcentric copper wire layer and
copper wire or copper tape binding
Sheath . . . . . . . . . . black PVC compound
Identification of cores
Phase conductors brown, black, grey (HD 308 S2:2002)
Marking
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking.
Product Catalogue
Power cables
AMCMK 3 1/2-core
1 kV power cable with PVC insulated aluminium conductors
Basic cable data
Construction data
External cable diameter (1)
Weight (1)
Delivery data
Standard delivery length
Drum
Total weight (1)
Mechanical data (2)
aluminium
copper
cable
cable + drum
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PEN conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short circuit phase conductor (4)
current for 1 second
PE conductor (5)
AMCMK
3x16Al/10Cu
AN 1 kV
AMCMK
3x25Al/16Cu
AN 1 kV
AMCMK
3x35Al/16Cu
AN 1 kV
AMCMK
3x50Al/16Cu
AN 1 kV
AMCMK
3x70Al/21Cu
AN 1 kV
AMCMK
3x95Al/29Cu
AN 1 kV
mm
kg/km
kg/km
kg/km
22
125
95
560
23
200
145
620
24
275
145
730
28
370
145
975
31
540
190
1300
35
750
260
1750
m
kg
1000
15G
710
500
K11
365
500
K12
485
500
K12
580
500
K14
765
500
K14
990
m
m
kN
kN
0,25
0,18
0,7
2,4
0,28
0,20
1,1
3,7
0,30
0,21
1,6
5,2
0,34
0,24
2,2
7,5
0,38
0,27
3,1
10,5
0,42
0,30
4,3
14,2
Ω/km
Ω/km
Ω/km
mH/km
µF/km
1,91
2,3
1,91
0,26
0,40
1,20
1,4
1,91
0,26
0,45
0,868
1,0
1,91
0,26
0,55
0,641
0,77
1,20
0,25
0,60
0,443
0,53
0,868
0,24
0,65
0,320
0,39
0,641
0,24
0,75
A
A
64
78
83
100
105
125
125
150
155
185
190
220
kA
kA
1,2
1,7
1,9
1,7
2,6
1,7
3,8
2,6
5,3
3,7
7,2
4,6
Basic cable data
Construction data
External cable diameter (1)
Weight (1)
aluminium
copper
cable
AMCMK
3x120Al/41Cu
AN 1 kV
AMCMK
3x150Al/41Cu
AN 1 kV
AMCMK
3x185Al/57Cu
AN 1 kV
AMCMK
3x240Al/72Cu
AN 1 kV
AMCMK
3x300Al/88Cu
AN 1 kV
mm
kg/km
kg/km
kg/km
39
945
370
2150
42
1160
370
2550
48
1460
525
3250
53
1910
660
4100
58
2390
790
5000
m
kg
500
K16
1270
500
K18
1500
500
K20
1950
500
K22
2450
500
K24
2950
m
m
kN
kN
0,47
0,33
5,4
18,0
0,51
0,36
6,7
20,0
0,58
0,41
8,3
20,0
0,64
0,45
8,5
20,0
0,70
0,49
8,5
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,253
0,31
0,443
0,23
0,80
0,206
0,25
0,443
0,23
0,80
0,164
0,20
0,320
0,23
0,85
0,125
0,15
0,253
0,23
0,85
0,100
0,13
0,206
0,23
0,90
A
A
220
255
250
290
285
330
330
375
380
430
kA
kA
9,1
6,7
11,4
6,7
14,0
8,8
18,2
11,4
22,8
13,9
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PEN conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short circuit phase conductor (4)
current for 1 second
PE conductor (5)
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 21
Power cables
AMCMK 4 1/2-core
1 kV power cable with PVC insulated aluminium conductors
Application
Construction
Fixed indoor, outdoor and underground installations.
Conductor . . . . . . . stranded, compacted and annealed
sector shaped aluminium conductor
Insulation . . . . . . . . PVC
Laying up . . . . . . . . three insulated phase conductors
and neutral conductor stranded
together
PE conductor . . . . concentric copper wire layer and
copper wire or copper tape binding
Sheath . . . . . . . . . . black PVC compound
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1
Certificate/approval
EEI, FI, CE
Rated voltage
U0/U = 0,6/1 kV
Um = 1,2 kV
Fire resistance class
Phase conductors brown, black, grey and neutral conductor blue (HD 308 S2:2002).
IEC 60332-3 cat B
Marking
Temperature range
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking.
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying . . –15˚C
22 | Draka Keila Cables
Identification of cores
Product Catalogue
Power cables
AMCMK 4 1/2-core
1 kV power cable with PVC insulated aluminium conductor
Basic cable data
Construction data
External cable diameter (1)
Weight (1)
aluminium
copper
cable
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short circuit phase conductor (4)
current for 1 second
PE conductor (5)
AMCMK
4x35Al/16Cu
AN 1 kV
AMCMK
4x50Al/16Cu
AN 1 kV
AMCMK
4x70Al/21Cu
AN 1 kV
AMCMK
4x95Al/29Cu
AN 1 kV
AMCMK
4x120Al/41Cu
AN 1 kV
mm
kg/km
kg/km
kg/km
28
365
145
955
32
495
145
1250
35
720
195
1600
40
1000
270
2200
44
1260
370
2650
m
kg
500
K12
570
500
K14
740
500
K16
995
500
K18
1330
500
K20
1670
m
m
kN
kN
0,34
0,24
2,1
7,0
0,39
0,28
3,0
10,0
0,42
0,3
4,2
14,0
0,48
0,34
5,7
19,0
0,53
0,37
7,2
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,868
1,00
1,15
0,27
0,45
0,641
0,77
1,15
0,27
0,50
0,443
0,53
0,868
0,26
0,55
0,32
0,39
0,641
0,26
0,65
0,253
0,31
0,443
0,26
0,70
A
A
105
125
125
150
155
185
190
220
220
255
kA
kA
2,6
2,6
3,8
2,6
5,3
3,7
7,2
4,6
9,1
6,7
AMCMK
4x150Al/41Cu
AN 1 kV
AMCMK
4x185Al/57Cu
AN 1 kV
AMCMK
4x240Al/72Cu
AN 1 kV
AMCMK
4x300Al/88Cu
AN 1 kV
mm
kg/km
kg/km
kg/km
48
1550
370
3150
53
1950
510
4000
60
2550
660
5100
66
3190
795
6300
m
kg
500
K20
3150
500
K22
2400
400
K22
3000
500
K24
3600
m
m
kN
kN
0,58
0,41
8,5
20,0
0,64
0,45
8,5
20,0
0,72
0,51
8,5
20,0
0,80
0,56
8,5
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,206
0,25
0,443
0,26
0,70
0,164
0,20
0,320
0,26
0,75
0,125
0,15
0,253
0,26
0,80
0,1
0,13
0,206
0,26
0,80
A
A
250
290
285
330
330
375
380
430
kA
kA
11,4
6,7
14,0
8,8
18,2
11,4
22,8
13,9
Basic cable data
Construction data
External cable diameter (1)
Weight (1)
aluminium
copper
cable
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short circuit phase conductor (4)
current for 1 second
PE conductor (5)
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 23
Power cables
MCMK 3-core
1 kV power cable with PVC insulated copper conductors
Application
Construction
For fixed installation indoors, outdoors and underground as well as in building structures, e.g. directly in
concrete. Not for installations subject to severe electrical interference (see MCCMK).
CE, EEI, FI, S
Conductor . . . . . . . annealed copper;
1,5–6 mm2 – solid;
10 mm2 – stranded, round (RM)
Insulation . . . . . . . . lead-free PVC
Laying up . . . . . . . . phase conductor and neutral conductor stranded together
Filling . . . . . . . . . . . filling compound
PE conductor . . . . concentric layer of copper wires and
an open helix of parallel copper wires
Sheath . . . . . . . . . . black, lead-free PVC compound
Rated voltage
Identification of cores
U0/U = 0,6/1 kV, Um = 1,2 kV
Colour marking . . . blue, brown
According to HD 308 S2:2002.
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1
Certificate/approval
Temperature range
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying. . . –15˚C
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force, pulling by phase conductors
Electrical data (2)
Maximum DC resistance of conductor 20˚C
Maximum AC resistance of conductor 70˚C
Maximum DC resistance of PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
Short circuit currents (2)
Maximum permissible short phase and neutral conductor (4)
circuit current for 1 second PE conductor (5)
Marking
Manufacturer, product name, FI-mark, year and week of
manufacture, meter marking.
MCMK
2x1,5/1,5 1 kV
64 100+ 06 021 22-2
MCMK
MCMK
2x2,5/2,5 1 kV 2x6/6 1 kV
06 021 25-3
06 021 23-9
MCMK
2x10/10 RM 1 kV
06 021 26-0
mm
kg/km
kg/km
11,5
41
165
12,5
66
200
16,5
159
370
19
268
550
m
kg
1000
K8
210
1000
K8
225
500
K8
220
500
K9
320
m
m
kN
0,14
0,09
0,15
0,15
0,10
0,25
0,19
0,13
0,60
0,23
0,16
1,00
Ω/km
Ω/km
Ω/km
mH/km
µF/km
12,1
14,5
12,1
0,34
0,25
7,41
8,87
7,41
0,32
0,30
3,08
3,69
3,08
0,30
0,35
1,83
2,19
1,83
0,28
0,40
A
A
26
14
35
20
57
33
77
62
kA
kA
0,18
0,24
0,30
0,42
0,70
1,0
1,1
1,7
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C.
24 | Draka Keila Cables
Product Catalogue
Power cables
MCMK 4-core
1 kV power cable with PVC insulated copper conductors
Application
Construction
For fixed installation indoors, outdoors and underground
as well as in building structures, e.g. directly in concrete.
Not for installations subject to severe electrical interference (see MCCMK).
CE, FI, S, EEI
Conductor . . . . . .annealed copper;
1,5–6 mm2 – solid round;
10 and 16 mm2 – stranded, round (RM)
Insulation . . . . . . .lead-free PVC
Laying up . . . . . . .three phase conductors stranded
together
Filling . . . . . . . . . .filling compound
PE conductor . . . .concentric layer of copper wires and an
open helix of parallel copper wires
Sheath . . . . . . . . .black, lead-free PVC compound
Rated voltage
Identification of cores
U0/U = 0,6/1 kV, Um = 1,2 kV
Colour marking . .brown, black, grey
According to HD 308 S2:2002.
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1
Certificate/approval
Temperature range
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying. . . –15˚C
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Min permissible bending radius during laying
Min permissible bending radius at final installation (3)
Max permissible pulling force, pulling by phase conductors
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
PE conductor 20˚C
Maximum DC resistance of
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
Short circuit currents (2)
Max permissible short circuit current for 1 second phase conductor (4)
PE conductor (5)
Manufacturer, product name, FI-mark, year and week of
manufacture, meter marking
MCMK
MCMK
MCMK
3x1,5/1,5 1 kV 3x2,5/2,5 1 kV 3x6/6 1 kV
06 021 52-9 06 021 53-6
06 021 55-0
MCMK
MCMK
3x10/10 RM 1 kV 3x16/16 RM 1 kV
06 021 56-7
06 021 57-4
mm
kg/km
kg/km
12
54
190
13
88
240
17
212
450
20
357
680
23
570
970
m
kg
1000
K8
220
1000
K9
290
500
K8
260
500
K9
390
500
K11
570
m
m
kN
0,15
0,10
0,22
0,16
0,11
0,37
0,21
0,15
0,90
0,24
0,16
1,5
0,28
0,19
2,4
Ω/km
Ω/km
Ω/km
mH/km
µF/km
12,1
14,5
12,1
0,34
0,25
7,41
8,87
7,41
0,32
0,30
3,08
3,69
3,08
0,30
0,35
1,83
2,19
1,83
0,28
0,40
1,15
1,38
1,15
0,26
0,40
A
A
26
14
35
20
57
33
77
62
100
82
kA
kA
0,18
0,24
0,30
0,42
0,7
1,0
1,1
1,7
1,8
2,7
64 100+
copper
cable
Marking
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 25
Power cables
MCMK 5-core
1 kV power cable with PVC insulated copper conductors
Application
Construction
For fixed installation indoors, outdoors and underground
as well as in building structures, e.g. directly in concrete.
Not for installations subject to severe electrical interference (see MCCMK).
EEI, CE, FI, S
Conductor . . . . . . . annealed copper
1,5–6 mm2 – solid
10 and 16 mm2 – stranded, round (RM)
Insulation . . . . . . . . lead-free PVC
Laying up . . . . . . . . three phase conductors and neutral
conductor stranded together
Filling . . . . . . . . . . . filling compound
PE conductor . . . . concentric layer of copper wires and
an open helix of parallel copper wires
Sheath . . . . . . . . . . black, lead-free PVC compound
Rated voltage
Identification of cores
U0/U = 0,6/1 kV, Um = 1,2 kV
Colour marking . . . blue, brown, black, grey
According to HD 308 S2:2002.
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1
Certificate/approval
Temperature range
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying . . .-15˚C
26 | Draka Keila Cables
Marking
Manufacturer, product name, FI-mark, year and week of
manufacture, meter marking
Product Catalogue
Power cables
MCMK 5-core
1 kV power cable with PVC insulated copper conductors
Basic cable data
MCMK
4x1,5/1,5 1 kV
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force, pulling by phase conductors
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
Short circuit currents (2)
Max permissible short circuit current for 1 second
phase and neutral conductor (4)
PE conductor (5)
MCMK
4x1,5/1,5 1 kV
MCMK
MCMK
4x2,5/2,5 1 kV 4x2,5/2,5 1 kV
drum
64 100+ 06 021 72-7
reel
06 021 92-5
drum
06 021 43-7
reel
06 021 93-2
mm
kg/km
kg/km
13
68
210
13
68
210
14
110
270
14
110
270
m
kg
1000
K8
235
100
reel
21
1000
K9
320
100
reel
27
m
m
kN
0,16
0,11
0,3
0,16
0,11
0,3
0,17
0,12
0,5
0,17
0,12
0,5
Ω/km
Ω/km
Ω/km
mH/km
µF/km
12,1
14,5
12,1
0,34
0,25
12,1
14,5
12,1
0,34
0,25
7,41
8,87
7,41
0,32
0,30
7,41
8,87
7,41
0,32
0,30
A
A
26
14
26
14
35
20
35
20
kA
kA
0,18
0,24
0,18
0,24
0,30
0,42
0,30
0,42
Basic cable data
MCMK
4x6/6 1 kV
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force, pulling by phase conductors
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
Short circuit currents (2)
Max permissible short circuit current for 1 second
phase and neutral conductor (4)
PE conductor (5)
MCMK
4x10/10 RM 1 kV
MCMK
4x16/16 RM 1 kV
drum
64 100+ 06 021 45-1
drum
06 021 46-8
drum
06 021 47-5
mm
kg/km
kg/km
18,5
265
520
22
447
790
25
712
1150
m
kg
500
K8
285
500
K11
480
500
K11
630
m
m
kN
0,22
0,15
1,2
0,25
0,17
2,0
0,29
0,20
3,2
Ω/km
Ω/km
Ω/km
mH/km
µF/km
3,08
3,69
3,08
0,30
0,35
1,83
2,19
1,83
0,28
0,40
1,15
1,38
1,15
0,26
0,40
A
A
57
33
77
62
100
82
kA
kA
0,70
1,0
1,1
1,7
1,8
2,7
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 27
Power cables
MCCMK 4-core
1 kV EMC power cable with PVC-insulated copper conductor
Application
Construction
Fixed indoor, outdoor and underground installation
where EMC properties are required.
Conductor . . . . . . . annealed copper;
2,5 and 6 mm2 – solid round;
10 and 16 mm2 – stranded round (RM)
Insulation . . . . . . . . lead-free PVC
Laying up . . . . . . . . three phase conductors stranded
together
Filling . . . . . . . . . . . filling compound
PE conductor . . . . copper foil and concentric layer of
copper wires
Sheath . . . . . . . . . . black, lead-free PVC compound
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60322-1
Certificate/approval
EEI, FI, CE
Rated voltage
U0/U = 0,6/1 kV
Um = 1,2 kV
Identification of cores
Colour marking . . . brown – black – grey
According to HD 308 S2:2002.
Temperature range
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . 160˚C
Lowest recommended temperature during laying . . –15˚C
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
PE conductor 20˚C
Maximum DC resistance of
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
Short circuit currents (2)
Maximum permissible short
phase conductor (4)
circuit current for 1 second
PE conductor (5)
Marking
Manufacturer, product name, FI-mark, year and week of
manufacture, meter marking
MCCMK
3x2,5/2,5 1 kV
64 100+ 06 020 53-9
MCCMK
MCCMK
MCCMK
3x6/6 1 kV
3x10/10 RM 1 kV 3x16/16 RM 1 kV
06 020 55-3 06 020 56-0
06 020 57-7
mm
kg/km
kg/km
14
88
260
18
212
470
21
357
700
24
570
1050
m
kg
1000
K9
320
1000
K11
560
1000
K12
820
1000
15G
1250
m
m
kN
0,16
0,11
0,37
0,22
0,15
0,90
0,25
0,17
1,5
0,30
0,20
2,4
Ω/km
Ω/km
Ω/km
mH/km
µF/km
7,41
8,87
7,41
0,32
0,30
3,08
3,69
3,08
0,30
0,35
1,83
2,19
1,83
0,26
0,40
1,15
1,38
1,15
0,26
0,40
A
A
35
20
57
33
77
62
100
82
kA
kA
0,18
0,24
0,30
0,42
0,7
1,0
1,1
1,7
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C.
28 | Draka Keila Cables
Product Catalogue
Power cables
MCCMK 5-core
1 kV EMC power cable with PVC-insulated copper conductor
Application
Construction
Fixed indoor, outdoor and underground installation
where EMC properties are required.
Rated voltage
Conductor . . . . . . . annealed copper
2,5 and 6 mm2 – solid round
10 and 16 mm2 – stranded round (RM)
Insulation . . . . . . . . lead-free PVC
Laying up . . . . . . . . three phase conductors and neutral
conductor stranded together
Filling . . . . . . . . . . . filling compound
PE conductor . . . . copper foil and concentric layer of
copper wires
Sheath . . . . . . . . . . black, lead-free PVC compound
U0/U = 0,6/1 kV, Um = 1,2 kV
Identification of cores
Temperature range
Colour marking . . . blue, brown, black, grey
According to HD 308 S2:2002.
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1
Certificate/approval
EEI, FI, CE
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying . . .-15˚C
Basic cable data
Manufacturer, product name, FI-mark, year and week of
manufacture, meter marking.
MCCMK
MCCMK
MCCMK
MCCMK
4x2,5/2,5 1 kV 4x6/6 1 kV 4x10/10 RM 1 kV 4x16/16 RM 1 kV
64 100+ 06 020 73-7 06 020 75-1 06 020 76-8
06 020 77-5
EAN code
Construction data
External cable diameter (1)
Weight (1)
Marking
copper
cable
Delivery data
Standard delivery length
Drum
cable + drum
Total weight (1)
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Electrical data (2)
Maximum DC resistance of conductor 20˚C
Maximum AC resistance of conductor 70˚C
Maximum DC resistance of PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In ground
conductor 70˚C
In air
conductor 70˚C
Short circuit currents (2)
Maximum permissible short phase conductor and
circuit current for 1 second neutral conductor (4)
PE conductor (5)
mm
kg/km
kg/km
14,5
110
290
19
265
540
22
447
830
25
712
1200
m
kg
1000
K9
350
1000
K11
640
1000
13G
970
1000
15G
1400
m
m
kN
0,18
0,12
0,50
0,23
0,16
1,2
0,27
0,18
2,0
0,30
0,20
3,2
Ω/km
Ω/km
Ω/km
mH/km
µF/km
7,41
8,87
7,41
0,32
0,30
3,08
3,69
3,08
0,30
0,35
1,83
2,19
1,83
0,28
0,40
1,15
1,38
1,15
0,26
0,40
A
A
35
20
57
33
77
62
100
82
kA
0,30
0,70
1,1
1,8
kA
0,42
1,0
1,7
2,7
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 29
Power cables
MCMK 3 1/2-core
1 kV power cable with PVC insulated copper conductors
Application
Construction
Fixed indoor, outdoor and underground installations.
Conductor . . . . . . . stranded, compacted and annealed
sector shaped copper conductor
Insulation . . . . . . . . PVC
Laying up . . . . . . . . three insulated phase conductors
stranded together
PE conductor . . . . concentric copper wire layer and
copper wire or copper tape binding
Sheath . . . . . . . . . . black PVC compound
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-3
Certificate/approval
EEI, FI, CE
Rated voltage
U0/U = 0,6/1 kV, Um = 1,2 kV
Fire resistance class
Phase conductors brown, black, grey.
According to HD 308 S2:2002.
IEC 60332-3 cat B
Marking
Temperature range
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying. . . –15˚C
30 | Draka Keila Cables
Identification of cores
Product Catalogue
Power cables
MCMK 3 1/2-core
1 kV power cable with PVC insulated copper conductors
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
PE conductor 20˚C
Maximum DC resistance of
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short
phase conductor (4)
circuit current for 1 second
PE conductor (5)
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
3x95/50 AN 1 kV
06 021 62-8
mm
kg/km
kg/km
23
800
1150
25
1050
1450
28
1460
2000
31
2080
2700
37
2880
3700
m
kg
500
K12
630
500
K12
815
500
K12
1090
500
K14
1470
500
K16
2050
m
m
kN
kN
0,28
0,20
1,1
7,5
0,30
0,21
1,5
10,5
0,34
0,24
2,2
15,0
0,38
0,26
3,1
20,0
0,45
0,31
4,2
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,727
0,87
1,15
0,26
0,45
0,524
0,63
1,15
0,26
0,55
0,387
0,47
0,727
0,25
0,60
0,268
0,32
0,524
0,24
0,65
0,193
0,23
0,387
0,24
0,75
A
A
107
130
135
160
160
190
200
240
245
285
kA
kA
2,8
2,7
4,0
2,7
5,7
4,4
8,0
5,7
10,9
7,2
3x120/70 AN 1 kV 3x150/70 AN 1 kV 3x185/95 AN 1 kV 3x240/120 AN 1 kV 3x300/150 AN 1 kV
64 100+ 06 021 63-5
06 021 64-2
06 021 65-9
06 021 66-6
06 021 75-8
mm
kg/km
kg/km
39
3710
4650
43
4430
5550
48
5630
7000
59
7350
9100
59
9240
11500
m
kg
500
K18
2560
500
K18
3000
500
K20
3850
500
K22
4950
500
K24
6200
m
m
kN
kN
0,47
0,33
5,4
20,0
0,52
0,37
6,7
20,0
0,58
0,41
8,3
20,0
0,64
0,45
8,5
20,0
0,71
0,50
8,5
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,153
0,19
0,268
0,23
0,80
0,124
0,15
0,268
0,23
0,80
0,0991
0,12
0,193
0,23
0,85
0,0754
0,097
0,153
0,23
0,85
0,0601
0,081
0,124
0,23
0,90
conductor 70˚C
conductor 70˚C
A
A
280
325
320
370
365
420
425
480
490
550
phase conductor (4)
PE conductor (5)
kA
kA
13,7
10,4
17,2
10,4
21,2
13,4
27,5
16,6
34,4
19,2
copper
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
PE conductor 20˚C
Maximum DC resistance of
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
In ground
Short circuit currents (2)
Maximum permissible short
circuit current for 1 second
3x25/16 AN 1 kV 3x35/16 AN 1 kV 3x50/25 AN 1 kV 3x70/35 AN 1 kV
64 100+ 06 021 58-1
06 021 59-8
06 021 60-4
06 021 61-1
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 31
Power cables
MCMK 4 1/2-core
1 kV power cable with PVC insulated copper conductors
Application
Construction
Fixed indoor, outdoor and underground installations.
Certificate/approval
Conductor . . . . . . . stranded, compacted and annealed
sector shaped copper conductor
Insulation . . . . . . . . PVC
Laying up . . . . . . . . three insulated phase conductors
and neutral conductor stranded
together
PE conductor . . . . concentric copper wire layer and
copper wire or copper tape binding
Sheath . . . . . . . . . . black PVC compound
FI, CE
Identification of cores
Rated voltage
Phase conductors brown, black, grey and neutral conductor blue. According to HD 308 S2:2002.
Fire resistance class
IEC 60332-3 cat B
Standards
SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-3
U0/U = 0,6/1 kV, Um = 1,2 kV
32 | Draka Keila Cables
Temperature range
Marking
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C
Lowest recommended temperature during laying . . –15˚C
Manufacturer, product name, date of manufacture,
outer sheath material designation, meter marking
Product Catalogue
Power cables
MCMK 4 1/2-core
1 kV power cable with PVC insulated copper conductors
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short phase and neutral conductor (4)
circuit current for 1 second PE conductor (5)
Basic cable data
EAN code
Construction data
External cable diameter (1)
Weight (1)
copper
cable
Delivery data
Standard delivery length
Drum
Total weight (1)
cable + drum
Mechanical data (2)
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation (3)
Maximum permissible pulling force with a pulling grip
Maximum permissible pulling force with a pulling eye
Electrical data (2)
Maximum DC resistance of
conductor 20˚C
Maximum AC resistance of
conductor 70˚C
Maximum DC resistance of
PE conductor 20˚C
Inductance (1)
Operating capacitance (1)
Current ratings (2)
In air
conductor 70˚C
In ground
conductor 70˚C
Short circuit currents (2)
Maximum permissible short phase and neutral conductor (4)
circuit current for 1 second PE conductor (5)
4x25/16 AN
1 kV
64 100+ 06 018 58-1
4x35/16 AN
1 kV
06 018 59-8
4x50/25 AN
1 kV
06 018 60-4
4x70/35 AN
1 kV
06 018 61-1
4x95/50 AN
1 kV
06 018 62-8
mm
kg/km
kg/km
26
1020
1450
28
1350
1850
32
1870
2500
35
2670
3450
41
3700
4750
m
kg
500
K11
780
500
K12
1020
500
K14
1370
500
K16
1920
500
K18
2610
m
m
kN
kN
0,32
0,22
1,5
10,0
0,34
0,24
2,1
14,0
0,39
0,28
3,0
20,0
0,42
0,30
4,2
20,0
0,50
0,35
5,7
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,727
0,87
1,15
0,28
0,40
0,524
0,63
1,15
0,27
0,45
0,387
0,46
0,727
0,27
0,50
0,268
0,32
0,524
0,26
0,55
0,193
0,23
0,387
0,26
0,65
A
A
107
130
135
160
160
190
200
240
245
285
kA
kA
2,8
2,7
4,0
2,7
5,7
4,4
8,0
5,7
10,9
7,2
4x120/70 AN
1 kV
64 100+ 06 018 63-5
4x150/70 AN
1 kV
06 018 64-2
4x185/95 AN
1 kV
06 018 65-9
4x240/120 AN
1 kV
06 018 66-6
4x300/150 AN
1 kV
06 018 67-3
mm
kg/km
kg/km
44
4740
5900
49
5710
7150
54
7230
8950
60
9450
12000
66
11900
14500
m
kg
500
K20
3300
500
K22
4000
500
K22
4900
500
K24
6500
500
K24
7750
m
m
kN
kN
0,53
0,37
7,2
20,0
0,59
0,42
8,5
20,0
0,65
0,46
8,5
20,0
0,72
0,51
8,5
20,0
0,8
0,56
8,5
20,0
Ω/km
Ω/km
Ω/km
mH/km
µF/km
0,153
0,19
0,268
0,26
0,70
0,124
0,15
0,268
0,26
0,70
0,0991
0,12
0,193
0,26
0,85
0,0754
0,097
0,153
0,26
0,80
0,0601
0,080
0,124
0,26
0,80
A
A
280
325
320
370
365
420
425
480
490
550
kA
kA
13,7
10,4
17,2
10,4
21,2
13,4
27,5
16,6
34,4
19,2
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C.
5) Initial temperature of PE conductor before short circuit 65˚C, final temperature of PE conductor after short circuit 160˚C.
Product Catalogue
Draka Keila Cables | 33
Power cables
MCMO
Control cable
Application
Bending radius
Cables for control, measuring and signal circuits of
electrical equipment for fixed surface or flush-mounted
installations, indoors, outdoors and protected underground. The concentric copper conductor forms a good
electromechanical protection and a moderate protection
against electrical interference.
Minimum recommended bending radius
- during installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
- in a final installation if bent only once . . . . . . . . . . . . . 8D
Maximum permissible tensile stress
during installation . . . . . . . . . . . . . . . . . . . . . .Ax50 N/mm2
Standard
SFS 3713
Certificate / approval
Construction
Conductor . . . . . . . . . . . annealed copper wire
Insulation . . . . . . . . . . . . black lead-free PVC, core identification by numbers
Filling . . . . . . . . . . . . . . . filling compound
Concentric conductor . . a layer of copper wires and an
open helix of parallel copper
wires
Sheath . . . . . . . . . . . . . . black lead-free PVC
CE, FI (FIMKO)
Temperature range
Maximum permissible temperature of conductor
- in continuous use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70˚C
- in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . –15˚C
Number of conductors and cross section n x mm2
EAN code (SSTL code)
Nominal overall diameter
Total weight
Direct current resistance at +20˚C max.
64 100+
mm
kg/km
conductor
Ω/km
concentric conductor Ω/km
drum
m
Standard delivery length
Electrical properties
Capacitance between two adjacent conductors at +20˚C and 50 Hz
Capacitance between one conductor and earth at +20˚C and 50 Hz
µF/km
µF/km
Number of conductors and cross section n x mm2
EAN code (SSTL code)
Nominal overall diameter
Total weight
Direct current resistance at +20˚C max.
64 100+
mm
kg/km
conductor
Ω/km
concentric conductor Ω/km
drum
m
Standard delivery length
Electrical properties
Capacitance between two adjacent conductors at +20˚C and 50 Hz
Capacitance between one conductor and earth at +20˚C and 50 Hz
34 | Draka Keila Cables
µF/km
µF/km
7 x 1,5
06 019 01-4
15
350
12,1
3,08
500/8E
12 x 1,5
06 019 02-1
19
500
12,1
3,08
400/8E
19 x 1,5
06 019 03-8
22
680
12,1
3,08
500/11G
27 x 1,5
06 019 04-5
26
900
12,1
3,08
500/11G
37 x 1,5
06 019 05-2
28
1150
12,1
2,6
400/11G
130 – 160
200 – 270
130 – 160
200 – 270
130 – 160
200 – 270
130 – 160
200 – 270
130 – 160
200 – 270
7 x 2,5
06 019 21-2
18
450
7,41
3,08
500/8E
12 x 2,5
06 019 22-9
22
690
7,41
3,08
500/11G
19 x 2,5
06 019 23-6
25
950
7,41
3,08
500/11G
27 x 2,5
06 019 24-3
29
1300
7,41
2,6
400/11G
130 – 160
210 – 280
130 – 160
210 – 280
130 – 160
210 – 280
130 – 160
210 – 280
Product Catalogue
Power cables
ARLC Aluminum Road Lighting Cable
1 kV outdoor lighting power cable with aluminum
conductors and copper signal conductor
Application
Certificate/approval
Fixed outdoor installations, ideal for laying in soil.
CE
Highest permissible conductor temperature
upon continuous load . . . . . . . . . . . . . . . . . . . . . . . . . .90˚C
Highest permissible conductor temperature
upon short circuit (up to 5 s).. . . . . . . . . . . . . . . . . . .250˚C
Lowest permissible temperature during laying . . . –15˚C
Identification of cores
Construction
Conductor . . . . . . . 16 mm2 – round single-wire aluminium conductor;
25–35 mm2 – round stranded,
compacted and annealed aluminium
conductor
Signal conductor . . 2,5 mm2 – round single-wire copper
conductor
Insulation . . . . . . . . black
Laying up . . . . . . . . four insulated conductors stranded
together
Sheath . . . . . . . . . . black halogen-free self-extinguishing
PE compound;
insulation and sheath are UV (1)
resistible and they don’t need extra
protection against sunlight.
1)
Product Catalogue
Phase conductors. . . . . brown, black, grey
PEN conductor . . . . . . . yellow-green
Signal conductor . . . . . black
Standards
HD 603-5D S1, IEC 60502-1,
IEC 60332-1 Cat. B, HD 308 S2:2002
Rated voltage
U0/U = 0,6/1 kV
Um = 1,2 kV
Marking
Manufacturer, product name, year/week of manufacture,
outer sheath material, meter marking
UV – ultraviolet radiation
Draka Keila Cables | 35
Power cables
EX
1 kV aerial bundled cable
Application
Construction
Overhead distribution cable.
Certificate/approval
Conductor . . . . . . . . . . . round, stranded and compacted
aluminium conductor
Insulation . . . . . . . . . . . . black UV (1) and weather resistant PE compound
Laying up . . . . . . . . . . . . insulated conductors are
stranded together
CE
Identification of cores
Rated voltage
U0/U = 0,6/1 kV, Um = 1,2 kV
Phase conductors. . . . . 1, 2 or 3 longitudinal ridges
Neutral conductor . . . . no ridges
Temperature range
Marking
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 135˚C
Manufacturer, year of manufacture.
Standards
HD 626-3I
Basic cable data
Construction data
Insulation thickness
Diameter (1)
Weight (1)
Delivery data
Standard delivery length
Drum
Mechanical data (2)
Minimum tensile strength
Electrical data (2)
Maximum DC resistance of
1)
36 | Draka Keila Cables
aluminium
conductor 20˚C
2x25 1 kV
4x25 1 kV
4x50 1 kV
4x95 1 kV
mm
mm
kg/km
1,3
19
205
1,3
22
405
1,4
28
700
1,6
38
1350
m
500
K8
500
K9
500
K11
500
K14
kN
4,1
4,1
7,3
13,7
Ω/km
1,20
1,20
0,641
0,320
UV – ultraviolet radiation
Product Catalogue
Power cables
AMKA
1 kV aerial bundled self supporting cable
Application
Construction
For overhead distribution as part of AMKA system. Messenger is used as PEN conductor. The cable can have
one optional conductor for street lighting.
Rated voltage
Conductor . . . . . . . . . . . 16 mm2 – round and solid aluminium conductor;
25–120 mm2 – round, stranded
and compacted aluminium
conductor
Insulation . . . . . . . . . . . . black UV (1) and weather resistant PE compound
Messenger . . . . . . . . . . . round, stranded and compacted
aluminium alloy conductor
Laying up . . . . . . . . . . . . insulated conductors are laid up
around the messenger
U0/U = 0,6/1 kV, Um = 1,2 kV
Identification of cores
Temperature range
Phase conductors. . . . . 2, 3 or 4 longitudinal ridges
Optional conductor . . . no ridges
Standards
SFS 2200, HD 626-5D S1
Certificate/approval
FI (SGS FIMKO), CE
Highest permissible conductor temperature:
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . . 135˚C
Lowest recommended temperature during laying. . . –20˚C
Basic cable data
Construction data
Diameter over bare conductor
Diameter over messenger
Effective diameter in wind
Weight
aluminium
cable
Delivery data
Standard delivery length
Drum
Total weight
cable + drum
Mechanical data
Minimum permissible bending radius during laying
Minimum permissible bending radius at final installation
Minimum tensile strength of the messenger
Initial modulus of elasticity of messenger
Final modulus of elasticity of messenger
Coefficient of linear expansion of messenger
Electrical data
Maximum DC resistance of phase
conductor 20˚C
AC resistance of phase
conductor 70˚C
Maximum DC resistance of of messenger conductor 20˚C
Inductance
Current ratings
In air
conductor 70˚C
Short circuit currents
Maximum permissible short circuit
phase conductor
current for 1 second
messenger
1)
Product Catalogue
Marking
Manufacturer, year of manufacture.
1x16+25
1 kV
3x16+25 4x16+25 3x25+35 3x35+50 3x50+70 3x70+95 3x120+95
1 kV
1 kV
1 kV
1 kV
1 kV
1 kV
1 kV
mm
mm
mm
kg/km
kg/km
4,4
5,8
11
100
135
4,4
5,8
20
185
270
4,4
5,8
22
225
330
5,8
6,8
23
285
390
6,8
8,0
27
390
530
8,0
9,6
31
540
700
9,6
11,3
36
775
1000
12,7
11,3
42
1185
1500
m
2000
K11
325
1000
K12
360
1000
K14
445
1000
K14
505
1000
K16
725
1000
K18
930
500
K14
695
500
K18
980
m
m
kN
N/mm 2
N/mm2
1/K
0,28
0,20
7,4
0,42
0,30
7,4
0,42
0,30
7,4
0,50
0,35
10,3
0,58
0,41
14,2
55000
63000
23x10-6
0,66
0,47
20,6
0,78
0,55
27,9
0,92
0,65
27,9
Ω/km
Ω/km
Ω/km
mH/km
1,91
2,3
1,38
0,29
1,91
2,3
1,38
0,35
1,91
2,3
1,38
0,35
1,20
1,4
0,986
0,34
0,868
1,0
0,720
0,34
0,641
0,77
0,493
0,33
0,443
0,53
0,363
0,31
0,253
0,30
0,363
0,30
A
75
70
70
95
115
140
180
250
kA
kA
1,0
1,5
1,0
1,5
1,0
1,5
1,6
2,1
2,3
3,0
3,2
4,3
4,5
5,9
7,8
5,9
kg
UV – ultraviolet radiation
Draka Keila Cables | 37
Power cables
AHXAMK-W 6/10 (12) kV
10 kV power cable
Application fields
Design
Suitable for cable ducts, outdoors, underground and in
water. Radial and longitudinal water sealed. Cable can
be installed by ploughing.
Conductor . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228 class 2
longitudinal watertight
Conductor screen. . extruded
Insulation . . . . . . . . XLPE, nominal thickness = 3,4 mm
Insulation screen . . extruded, bonded
Bedding . . . . . . . . . semiconductive water-blocking tape
Screen . . . . . . . . . . aluminium foil bonded tightly to sheath
Sheath . . . . . . . . . . black UV (1) resistant LLD PE
Centre conductor. . round, stranded and compacted
copper conductor, acc. to IEC 60228
class 2
Laying up . . . . . . . . three cores are stranded around the
centre conductor
Standard
CENELEC HD 620 Part 5 Section F
Impulse voltage
75 kV
Flame propagation class
The PE jacket is not flame-resistant.
Temperature range
Highest permissible conductor temperature
in continuous operation . . . . . . . . . . . . . . . . . . . . . . . .90˚C
Lowest temperature during installation . . . . . . . . . . –20˚C
below 0˚C special precaution shall be taken
Marking
E.g. AHXAMK-W 6/10kV 3X240+70Cu DRAKA SE “year”.
Bending radius
At laying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
When installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
Number of cores x cross section of conductor
Diameter over insulation
Single cable diameter (approx.)
Complete cable diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Electrical data
Resistance of conductor
Resistance of centre conductor
Inductance
Reactance
Capacitance
Charging current
mm2
mm
mm
mm
kg/100 m
m
3x95Al+35Cu
19,5
28
60
250
500
K24
3x120Al+35Cu
21
29
62
275
500
K26
3x150Al+35Cu
22,5
31
66
315
500
K26
3x185Al+35Cu
25
33
71
355
500
K26
3x240Al+35Cu
27,1
35
88
405
500
K26
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,320
0,524
0,31
0,10
0,30
0,7
0,253
0,524
0,30
0,10
0,32
0,7
0,206
0,524
0,29
0,09
0,35
0,8
0,164
0,524
0,28
0,09
0,40
0,9
0,125
0,524
0,27
0,09
0,43
0,9
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
38 | Draka Keila Cables
Product Catalogue
Power cables
AHXAMK-W 12/20 (24) kV
20 kV power cable
Application fields
Impulse voltage
Suitable for cable ducts, outdoors, underground and
in water. Radial and longitudinal water sealed. Can be
installed by ploughing.
125 kV
Design
Standard
CENELEC HD 620 Part 5 Section F
Flame propagation class
The PE-jacket is not flame-resistant.
Temperature range
Highest permissible conductor temperature
in continuous operation . . . . . . . . . . . . . . . . . . . . . . . .90˚C
Lowest temperature during installation . . . . . . . . . . –20˚C
below 0˚C special precaution shall be taken
Bending radius
At laying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
When installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
Number of cores x cross section of conductor
Diameter over insulation
Single cable diameter (approx.)
Complete cable diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Electrical data
Resistance of conductor
Resistance of centre conductor
Inductance
Reactance
Capacitance
Charging current
Standard drum size
Electrical data
Resistance of conductor
Resistance of centre conductor
Inductance
Reactance
Capacitance
Charging current
Marking
Eg. AHXAMK-W 12/20kV 3X240+70Cu DRAKA SE “year”.
mm2
mm
mm
mm
kg/100 m
m
3x50Al+35Cu
20,5
28
60
240
500
K24
3x70Al+35Cu
22,8
29
65
265
500
K24
3x95Al+35Cu
24,5
32
70
305
500
K24
3x120Al+35Cu
25,8
33
72
330
500
K26
3x150Al+35Cu
26,6
34
75
375
500
K26
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,641
0,524
0,39
0,12
0,16
0,7
0,443
0,524
0,42
0,13
0,18
0,7
0,320
0,524
0,40
0,13
0,21
0,8
0,253
0,524
0,39
0,12
0,22
0,8
0,206
0,524
0,37
0,12
0,24
0,9
Number of cores x cross section of conductor
Diameter over insulation
Single cable diameter (approx.)
Complete cable diameter (approx.)
Weight (approx.)
Standard delivery length
Conductor . . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228 class 2
longitudinal watertight
Conductor screen. . . extruded
Insulation . . . . . . . . . XLPE, nominal thickness 5,5 mm
Insulation screen . . . extruded, bonded
Bedding . . . . . . . . . . semiconductive water-blocking tape
Screen . . . . . . . . . . . aluminium foil bonded tightly to sheath
Sheath . . . . . . . . . . . black UV (1) resistant LLD PE
Centre conductor . . . round, stranded and compacted
copper conductor, acc. to
IEC 60228 class 2
Laying up . . . . . . . . . three cores are stranded around the
centre conductor
mm2
mm
mm
mm
kg/100 m
m
3x185Al+35Cu
29,0
36
80
420
500
K26
3x240Al+35Cu
30,5
39
86
500
500
K28
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,164
0,524
0,36
0,11
0,26
1,0
0,125
0,524
0,35
0,11
0,29
1,1
3x240Al+70Cu 3x300Al+70Cu
33
43
94
88
530
625
500
500
K28
K28
31,3
39
0,125
0,268
0,35
0,11
0,29
1,1
0,100
0,268
0,34
0,11
0,32
1,2
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
Product Catalogue
Draka Keila Cables | 39
Power cables
AXLJ-TT 7/12 kV
10 kV power cable
Application fields
Bending radius
Single core distribution cable suitable for laying outdoors
in 1- or 3-phase formation. Installation in pipes and in
ground/water. Both radial and longitudinal water sealed.
Can be installed by ploughing.
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Alternative designation
Design
Conductor���������������������� stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen���������� extruded
Insulation������������������������ XLPE, min. thickness= 2,96 mm
Insulation screen���������� extruded bonded
Longitudinal water
sealing���������������������������� swellable conducting tape
Concentric conductor���� annealed copper wires
Radial water sealing������ aluminium PE laminate
Sheath���������������������������� black UV (1) resistant LLD PE
SE-N10XC7A5T5E-AR
Standard
SS 424 14 16 CENELEC HD 620 Part 5 Section K
Fire propagation class
F1 acc. to SS 424 14 75
Material declaration
AXLJ-TT
Marking
Impulse voltage
E.g. AXLJ-TT 08DRAKA TSLE 12kV 1X240 AFR/25
“Date”, meter marked.
75 kV
Temperature range
In continuous operation max. conductor temp.. . . . 90˚C
Lowest cable temperature under installation. . . . . –20˚C
below 0˚C special precaution shall be taken
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
mm2
mm
mm
kg/100 m
m
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance in trefoil/flat formation (2) (3)
Reactance
Capacitance
Earth fault current
1x50/16
16,0
23,3
59,7
500
K11
0070410
1x95/16
19,3
26,6
79,4
500
K12
0070420
1x150/25
22,2
29,7
107,4
500
K12
0070440
1x240/25
26,1
33,8
141,4
500
K14
0070460
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,641
1,2
0,40/0,73
0,29
0,23
1,5
0,320
1,2
0,36/0,66
0,21
0,30
2,0
0,206
0,8
0,34/0,63
0,20
0,35
2,3
0,125
0,8
0,31/0,58
0,18
0,43
2,8
Electrical data
Current rating at core temp. 65˚C in ground (3)
Current rating at core temp. 65˚C in air (3)
Current rating at core temp. 90˚C in air (3)
Max. short circuit current on the conductor during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor during 1 s at initial temp. 90˚C
A
A
A
kA
kA
170
165
205
5,1
4,7
250
255
310
9,7
9,0
315
325
395
15,3
14,2
395
420
515
24,4
22,7
Nominal values unless otherwise specified.
1) UV – ultraviolet radiation
2) Cable distance, installation flat formation = 70 mm.
3) Trefoil with screen grounded in both ends.
40 | Draka Keila Cables
Product Catalogue
Power cables
AXLJ-TT 14/24 kV
20 kV power cable
Application fields
Bending radius
Single core, distribution cable for outdoors use in 3-phase
formation. Installation in pipes and ground/water. Both
radial and longitudinal water sealed. Can be installed by
ploughing.
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Alternative designation
Design
AXLJ-TT
Conductor���������������������� stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen���������� extruded
Insulation������������������������ XLPE, min. thickness = 4,85 mm
Insulation screen���������� extruded bonded
Longitudinal water
sealing���������������������������� swellable conducting tape
Concentric conductor���� annealed copper wires
Radial water sealing������ aluminium PE laminate
Sheath���������������������������� black UV (1) resistant LLD PE
Impulse voltage
Marking
125 kV
E.g. AXLJ-TT 08DRAKA TSLE 24 kV 1X150 AFR/25
“year”, meter marked.
SE-N20XC7A5T5E-AR
Standard
CENELEC HD 620 Part 5 Section K
Fire propagation class
F1 acc. to SS 424 14 75
Material declaration
Temperature range
In continuous operation max. conductor temp. . . . . 90˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken.
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance in trefoil/flat formation (2) (3)
Reactance
Capacitance
Earth fault current
Electrical data
Current rating at core temp. 65˚C in ground (3)
Current rating at core temp. 65˚C in air (3)
Current rating at core temp. 90˚C in air (3)
Max. short circuit current on the conductor
during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor
during 1 s at initial temp. 90˚C
mm2
mm
mm
kg/100 m
m
1x50/16
20,4
27,7
70,6
500
K12
1205011702
1x95/16
23,7
31,2
98,5
500
K12
0070520
1x150/25
26,6
34,3
120,5
500
K14
1205012102
1x240/25
30,5
38,6
165,2
500
K16
0070560
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,641
1,2
0,44/0,74
0,23
0,17
2,2
0,320
1,2
0,39/0,67
0,21
0,20
2,6
0,206
0,8
0,37/0,63
0,20
0,24
3,2
0,125
0,8
0,34/0,59
0,19
0,29
3,8
A
A
A
kA
170
165
205
5,1
250
255
310
9,7
315
325
395
15,3
395
420
515
24,4
kA
4,7
9,0
14,2
22,7
Nominal values unless otherwise specified.
1) UV – ultraviolet radiation
2) Cable distance, installation flat formation = 70 mm
3) Trefoil with screen grounded in both ends
Product Catalogue
Draka Keila Cables | 41
Power cables
AXLJ-TTCL TSLF 14/24 kV
20 kV power cable
Application fields
Bending radius
Single core and three core, distribution cable for outdoors
use in three phase formation. Installation in pipes and
ground/water. Both radial and longitudinal water sealed. Can
be ploughed down. Possibility for electric testing of sheath
and detecting of damages due to semiconductive outer layer.
At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Alternative designation
125 kV
Conductor���������������������� stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen���������� extruded
Insulation������������������������ XLPE, nom. thickness = 5,5 mm
Insulation screen���������� extruded bonded
Longitudinal water
sealing���������������������������� swellable conducting tape
Concentric conductor���� annealed copper wires
Radial water sealing������ aluminium PE laminate, bonded
to sheath
Sheath���������������������������� LLD PE, natural
Semiconductive layer���� black UV (1) resistant, extruded
bonded to the outer sheath
Laying up 3-core����������� three stranded single core cables
Temperature range
Marking
In continuous operation max. conductor temp. . . . . 90˚C
Lowest cable temperature during laying. . . . . . . . . –20˚C
and below 0˚C special precaution shall be taken
E.g. AXLJ-TTCL 08DRAKA TSLF 24 kV 1X150 AFR/25
“year”, meter marked.
SE-N20XC7A5T5E-AR
Standard
CENELEC HD 620 Part 5 Section K
Fire propagation class
F1 acc. to SS 424 14 75
Material declaration
AXLJ-TT
Impulse voltage
Number of cores x cross section of conductor mm2
Diameter over insulation
mm
Thickness of sheath
mm
Overall diameter (approx.)
mm
Weight (approx.)
kg/100 m
Standard delivery length
m
Standard drum size
Electrical data at +20˚C
Conductor resistance
Ω/km
Screen resistance
Ω/km
Inductance in trefoil/flat formation (2) (3)
mH/km
Reactance in trefoil/flat formation (2) (3)
Ω/km
Capacitance
µF/km
Charging current
A/km
Current ratings
Current rating at core
- temp. 65˚C in ground (3)
A
- temp. 65˚C in air (3)
A
- temp. 90˚C in air (3)
A
Max. short circuit current on the conductor
- during 1 s at initial temp. 65˚C
kA
- during 1 s at initial temp. 90˚C
kA
Design
1x50/16
20,4
1,8
29
71
500
K12
1x95/25
23,7
1,9
32
100
500
K12
1x150/25
26,6
2,0
35
121
500
K14
1x240/35
30,5
2,2
40
167
500
K16
1x400/35
36,0
2,3
45
228
500
K18
3x1x50/16
20,4
1,8
60
210
500
K24
3x1x95/25
23,7
1,9
69
295
500
K26
3x1x150/25
26,6
2,0
75
360
500
K26
3x1x240/35
30,5
2,2
84
510
500
K28
0,641
1,15
0,44/0,74
0,14/0,23
0,17
0,6
0,320
0,727
0,39/0,67
0,12/0,21
0,20
0,8
0,206
0,727
0,37/0,63
0,12/0,20
0,24
0,9
0,125
0,524
0,34/0,59
0,11/0,19
0,29
1,1
0,0778
0,524
0,32/0,55
0,10/0,17
0,36
1,4
0,641
1,15
0,44
0,14
0,17
0,6
0,320
0,727
0,39
0,12
0,20
0,8
0,206
0,727
0,37
0,12
0,24
0,9
0,125
0,524
0,34
0,11
0,29
1,1
170
160
195
250
230
280
315
300
370
395
400
490
525
555
680
170
160
195
250
230
280
315
300
370
395
400
490
5,2
4,7
9,9
8,9
15,6
14,2
25,0
22,7
41,6
37,8
5,2
4,7
9,9
8,9
15,6
14,2
25,0
22,7
1) UV – ultraviolet radiation
2) Cable distance, installation flat formation = 70 mm
3) Trefoil with screen grounded in both ends
42 | Draka Keila Cables
Product Catalogue
Power cables
AXLJ-TT 7/12 kV (3-core)
10 kV power cable
Application fields
Temperature range
Three core cable designed for replacement of bare overhead lines outdoors. Primary developed to be ploughed
down but thanks to the robust design the cable can stand
the stresses that appears when laying in lake with calm
water and limited deep. The design with water swellable
yarn and aluminium foil bonded to the sheath makes the
cable radial and longitudinal water sealed.
In continuous operation max. conductor temp. . . . . 90˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken
Alternative designation
Bending radius
At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Design
SE-N10XC7A5T5E-AR
Conductor���������������������� stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen���������� extruded
Insulation������������������������ XLPE, min. thickness = 2,96 mm
Insulation screen���������� extruded bonded
Longitudinal water
sealing���������������������������� swellable conducting tape and
water swellable yarn
Concentric conductor�� annealed copper wires
Radial water sealing������ aluminium foil bonded to the
sheath
Sheath���������������������������� black UV (1) resistant LLD PE
Standards
SS 424 14 16, CENELEC HD 620 Part 6 Section M
Fire propagation class
F1 acc. to SS 424 14 75
Material declaration
AXLJ-TT
Impulse voltage
75 kV
Marking
E.g. AXLJ-TT 7/12kV 3X95/16 DRAKA SE “Date”, meter marked.
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter single core (approx.)
Overall diameter whole cable (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground
Current rating at core temp. 65˚C in air
Current rating at core temp. 90˚C in air
Max. short circuit current on the conductor
during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor
during 1 s at initial temp. 90˚C
Max. impulse current
mm2
mm
mm
mm
kg/100 m
m
3x25/16
13,9
14,9
37,6
108,1
500
K16
0071000
3x50/16
16,0
17
42,3
142,0
500
K18
0071010
3x95/16
19,3
20,3
49,8
202,9
500
K20
0071020
3x150/25
22,2
23,2
56,7
279,3
500
K22
0071030
3x240/25
26,1
27,1
65,5
384,2
500
K24
0071040
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
1,2
1,2
0,37
0,12
0,19
0,4
0,641
1,2
0,34
0,11
0,23
0,4
0,320
1,2
0,31
0,10
0,30
0,6
0,206
0,8
0,29
0,09
0,35
0,7
0,125
0,8
0,27
0,09
0,43
0,8
A
A
A
kA
100
90
110
2,5
145
130
160
5,1
205
190
230
9,7
260
250
305
15,3
340
330
400
24,4
kA
2,3
4,7
9,0
14,2
22,7
kA
-
55
65
70
70
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
Product Catalogue
Draka Keila Cables | 43
Power cables
AXLJ-TT 14/24 kV (3-core)
20 kV power cable
Application fields
Impulse voltage
Three core cable designed for replacement of bare
overhead lines outdoors. Primary developed to be
ploughed down but thanks to the robust design the
cable can stand the stresses that appears when laying
in lake with calm water and limited deep. The design
with water swellable yarn and aluminium foil bonded
to the sheath makes the cable radial and longitudinal
water sealed.
125 kV
Alternative designation
SE-N20XC7A5T5E-AR
Standard
CENELEC HD 620 Part 6 Section M
Fire propagation class
F1 acc. to SS 424 14 75
Temperature range
In continuous operation max. conductor temp. . . . . 90˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken
Bending radius
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Design
Conductor������������������������stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen ����������extruded
Insulation��������������������������XLPE, min. thickness = 4,85 mm
Insulation screen������������extruded bonded
Longitudinally water
sealed��������������������������������swellable conducting tape and
water swellable yarn
Concentric conductor����annealed copper wires
Radial water sealing������aluminium foil bonded to the
sheath
Sheath������������������������������black UV (1) resistant LLD PE
Marking
E.g. AXLJ-TT 14/24 kV 3x95/16 DRAKA SE “Date”, meter
marked.
Material declaration
AXLJ-TT
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter single core (approx.)
Overall diameter whole cable (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground
Current rating at core temp. 65˚C in air
Current rating at core temp. 90˚C in air
Max. short circuit current on the conductor
during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor
during 1 s at initial temp. 90˚C
Max. impulse current
mm2
mm
mm
mm
kg/100 m
m
3x25/16
18,1
18,9
47,2
155,4
500
K20
0071050
3x50/16
20,2
21,0
52,2
194,6
500
K20
0071060
3x95/16
23,5
24,3
59,7
266,9
500
K24
0071070
3x150/25
26,4
27,2
66,3
344,2
500
K24
0071080
3x240/25
30,3
31,1
75,3
461,5
500
K26
0071090
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
1,2
1,2
0,42
0,13
0,14
0,5
0,641
1,2
0,38
0,12
0,17
0,6
0,320
1,2
0,34
0,11
0,20
0,8
0,206
0,8
0,32
0,10
0,24
0,9
0,125
0,8
0,30
0,09
0,29
1,1
A
A
A
kA
100
90
110
2,5
145
130
160
5,1
205
190
230
9,7
260
250
305
15,3
340
330
400
24,4
kA
2,3
4,7
9,0
14,2
22,7
kA
-
55
65
70
70
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
44 | Draka Keila Cables
Product Catalogue
Power cables
AXLJ-RMF 7/12 kV
10 kV power cable
Application fields
Impulse voltage
Three core cable designed for replacement of bare
overhead lines outdoors. Primary developed to be
ploughed down but thanks to the robust design it can
stand the stresses that appears when laying in water.
75 kV
Alternative designation
SE-N10XC7V-AR
Bending radius
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Design
Standards
AXLJ LT, -F, -RMF
Conductor . . . . . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen . . . . . extruded
Insulation . . . . . . . . . . . . XLPE, min. thickness = 2,96 mm
Insulation screen . . . . . extruded bonded
Taping . . . . . . . . . . . . . . . conductive tape
Concentric conductor. . annealed copper wires
Sheath . . . . . . . . . . . . . . black UV (1) resistant LLD PE
Temperature range
Marking
In continuous operation max. conductor temp . . . . .90˚C
Lowest cable temperature under installation . . . . . –20˚C
and below 0˚C special precaution shall be taken
E.g. AXLJ-RMF 7/12 KV 3X150/25 LT DRAKA SE “year”.
S 424 14 16
CENELEC HD 620 Part 6 Section M
Fire propagation class
F1 acc. to SS 424 14 75
Material declaration
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground
Current rating at core temp. 65˚C in air
Current rating at core temp. 90˚C in air
Max. short circuit current on the conductor
during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor
during 1 s at initial temp. 90˚C
Max. impulse current
mm2
mm
mm
kg/100 m
m
3x25/16
14,0
39,1
103,5
500
K16
1040031502
3x50/16
16,2
44,0
135,4
500
K18
1040031702
3x95/16
19,5
51,6
195,1
500
K20
1040031902
3x150/25
22,4
58,4
267,1
500
K22
1040032102
3x240/25
26,3
67,2
372,8
500
K24
1040032302
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
1,2
1,2
0,38
0,12
0,19
0,4
0,641
1,2
0,34
0,11
0,23
0,4
0,320
1,2
0,31
0,10
0,30
0,6
0,206
0,8
0,29
0,09
0,35
0,7
0,125
0,8
0,27
0,09
0,42
0,8
A
A
A
kA
100
90
110
2,5
145
130
160
5,1
205
190
230
9,7
260
250
305
15,3
340
330
400
24,4
kA
2,3
4,7
9,0
14,2
22,7
kA
-
55
65
70
70
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
Product Catalogue
Draka Keila Cables | 45
Power cables
AXLJ-RMF 14/24 kV
20 kV power cable
Application fields
Impulse voltage
Three core cable designed for replacement of bare
overhead lines outdoors. Primary developed to be
ploughed down but thanks to the robust design it can
stand the stresses that appears when laying in water.
125 kV
Alternative designation
SE-N20XC7V-AR
Bending radius
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Design
Standards
S 424 14 16, CENELEC HD 620 Part 6 Section M
Fire propagation class
F1 acc. to SS 424 14 75
Temperature range
Conductor . . . . . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen . . . . . extruded
Insulation . . . . . . . . . . . . XLPE, min. thickness = 4,85 mm
Insulation screen . . . . . extruded bonded
Taping . . . . . . . . . . . . . . . conductive tape
Concentric conductor . . annealed copper wires
Sheath . . . . . . . . . . . . . . black UV (1) resistant LLD PE
In continuous operation max. conductor temp . . . . .90˚C
Lowest cable temperature under installation . . . . . –20˚C
and below 0˚C special precaution shall be taken
Marking
Material declaration
E.g. AXLJ-RMF 14/24 KV 3X150/25 LT DRAKA SE “year”.
AXLJ LT, -F, -RMF
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground
Current rating at core temp. 65˚C in air
Current rating at core temp. 90˚C in air
Max. short circuit current on the conductor
during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor
during 1 s at initial temp. 90˚C
Max. impulse current
mm2
mm
mm
kg/100 m
m
3x25/16
18,2
49,0
147,2
500
K20
1045031502
3x50/16
20,4
53,9
185,1
500
K20
1045031702
3x95/16
23,7
61,4
253,9
500
K24
1045031902
3x150/25
26,7
68,1
328,1
500
K24
1045032102
3x240/25
30,7
77,1
445,5
500
K26
1045032302
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
1,2
1,2
0,43
0,14
0,14
0,5
0,641
1,2
0,39
0,12
0,16
0,6
0,320
1,2
0,35
0,11
0,20
0,8
0,206
0,8
0,32
0,10
0,24
0,9
0,125
0,8
0,30
0,09
0,29
1,1
A
A
A
kA
100
90
110
2,5
145
130
160
5,1
205
190
230
9,7
260
250
305
15,3
340
330
400
24,4
kA
2,3
4,7
9,0
14,2
22,7
kA
-
55
65
70
70
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
46 | Draka Keila Cables
Product Catalogue
Power cables
AXQJ-RMF 7/12 kV
10 kV halogen-free power cable
Application fields
Material declaration
Halogen-free and fire classified cable. No emittance of
corrosive gases, low smoke density in case of fire. Primary
developed for installation indoors, tunnels etc. The cable
can also with advantage be installed outdoors and in
ground. Ploughing down is not recommended.
AXQJ-F, –RMF
Alternative designation
Standards
Bending radius
Design
SS 424 14 16
CENELEC HD 620 Part 6 Section M
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Conductor . . . . . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen . . . . . extruded
Insulation . . . . . . . . . . . . XLPE, min. thickness = 2,96 mm
Insulation screen . . . . . extruded bonded
Taping . . . . . . . . . . . . . . . conductive tape
Concentric conductor. . annealed copper wires
Sheath . . . . . . . . . . . . . . halogen-free compound, black
Fire propagation class
F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and
SS-EN 50266-2-3
Temperature range
In continuous operation max. conductor temp . . . . .90˚C
Lowest cable temperature under installation . . . . . –20˚C
and below 0˚C special precaution shall be taken.
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground
Current rating at core temp. 65˚C in air
Current rating at core temp. 90˚C in air
Max. short circuit current on the conductor during 1 s at
initial temp. 70˚C
Max. short circuit current on the conductor during 1 s at
initial temp. 90˚C
Max. impulse current
75 kV
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
SE-N10XC7Z1-AR
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance
Impulse voltage
Marking
E.g. AXQJ-RMF 7/12 kV 3x150/25 LT F4B DRAKA SE
“Date”, meter marked.
mm2
mm
mm
kg/100 m
m
3x50/16
16,0
43,6
153,2
500
K18
0071210
3x95/16
19,3
51,1
219,4
500
K20
0071220
3x150/25
22,2
58,0
297,3
500
K22
0071230
3x240/25
26,1
66,8
405,3
500
K24
0071240
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,641
1,2
0,34
0,11
0,23
0,4
0,320
1,2
0,31
0,10
0,30
0,6
0,206
0,8
0,29
0,09
0,35
0,7
0,125
0,8
0,27
0,09
0,43
0,8
A
A
A
kA
145
130
160
5,1
205
190
230
9,7
260
250
305
15,3
340
330
400
24,4
kA
4,7
9,0
14,2
22,7
kA
55
65
70
70
Nominal values unless otherwise specified.
Product Catalogue
Draka Keila Cables | 47
Power cables
AXQJ-RMF 14/24 kV
20 kV halogen-free power cable
Application fields
Material declaration
Halogen-free and fire classified cable. No emittance
of corrosive gases, low smoke density in case of fire.
Primary developed for installation indoors, tunnels etc.
The cable can also with advantage be installed outdoors
and in ground. Ploughing down is not recommended.
AXQJ-F, –RMF
Alternative designation
Standards
Bending radius
Design
SS 424 14 16
CENELEC HD 620 Part 6 Section M
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Conductor . . . . . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water sealed
Conductor screen . . . . . extruded
Insulation . . . . . . . . . . . . XLPE, min. thickness = 4,85 mm
Insulation screen . . . . . extruded bonded
Taping . . . . . . . . . . . . . . . conductive tape
Concentric conductor. . annealed copper wires
Sheath . . . . . . . . . . . . . . halogen-free compound, black
Fire propagation class
F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and
SS-EN 50266-2-3
Temperature range
In continuous operation max. conductor temp . . . . .90˚C
Lowest cable temperature under installation . . . . . –20˚C
and below 0˚C special precaution shall be taken.
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground
Current rating at core temp. 65˚C in air
Current rating at core temp. 90˚C in air
Max. short circuit current on the conductor during 1 s at
initial temp. 70˚C
Max. short circuit current on the conductor during 1 s at
initial temp. 90˚C
Max. impulse current
125 kV
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
SE-N20XC7Z1-AR
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance
Impulse voltage
Marking
Eg. AXQJ-RMF 14/24 kV 3x150/25 LT F4B DRAKA SE
“Date”, meter marked.
mm2
mm
mm
kg/100 m
m
3x50/16
20,2
53,5
210,2
500
K20
0071250
3x95/16
23,5
61,0
286,2
500
K24
0071260
3x150/25
26,4
67,6
367,0
500
K24
0071270
3x240/25
30,3
76,6
488,3
500
K26
0071280
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,641
1,2
0,38
0,12
0,17
0,6
0,320
1,2
0,34
0,11
0,20
0,8
0,206
0,8
0,32
0,10
0,24
0,9
0,125
0,8
0,30
0,09
0,29
1,1
A
A
A
kA
145
130
160
5,1
205
190
230
9,7
260
250
305
15,3
340
330
400
24,4
kA
4,7
9,0
14,2
22,7
kA
55
65
70
70
Nominal values unless otherwise specified.
48 | Draka Keila Cables
Product Catalogue
Power cables
AXQJ-F 7/12 kV
10 kV halogen-free power cable
Application fields
Material declaration
Halogen-free and fire classified single core cable. No
emittance of corrosive gases, low smoke density in case
of fire. Distribution cable for indoors and outdoors use
in 3-phase formation. Installation in pipes and ground.
Ploughing down is not recommended.
AXQJ-F, –RMF
Alternative designation
SE-N10XC7Z1-AR
Standards
SS 424 14 16
CENELEC HD 620 Part 5 Section K
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Fire propagation class
F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and
SS-EN 50266-2-3
Temperature range
In continuous operation max. conductor temp . . . . .90˚C
Lowest cable temperature under installation . . . . . –20˚C
and below 0˚C special precaution shall be taken
Impulse voltage
75 kV
Bending radius
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Design
Conductor . . . . . . . . . . . stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water
sealed
Conductor screen . . . . . extruded
Insulation . . . . . . . . . . . . XLPE, min. thickness = 2,96 mm
Insulation screen . . . . . extruded bonded
Concentric conductor. . annealed copper wires
Sheath . . . . . . . . . . . . . . halogen-free compound, black
Marking
E.g. AXQJ-F 7/12 kV 1x630/35 F4B FASTSITTANDE SKIKT
DRAKA SE “Date”, meter marked.
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
Inductance in trefoil/flat formation (1) (2)
Reactance
Capacitance
Charging current
Electrical data
Current rating at core temp. 65˚C in ground (2)
Current rating at core temp. 65˚C in air (2)
Current rating at core temp. 90˚C in air (2)
Max. short circuit current on the conductor during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor during 1 s at initial temp. 90˚C
mm2
mm
mm
kg/100 m
m
1x240/25
26,1
33,5
149,4
500
K14
0071340
1x500/35
34,6
42,7
254,9
500
K18
0071370
1x630/35
38,7
46,9
302,4
500
K20
0071380
1x800/35
43,0
52,0
365,0
500
K22
Ω/km
Ω/km
mH/km
0,0605
0,6
0,28/0,52
0,16
0,59
1,1
0,0469
0,6
0,27/0,50
0,16
0,67
1,3
0,0367
0,524
0,27
Ω/km
µF/km
A/km
0,125
0,8
0,31/0,58
0,18
0,43
0,8
A
A
A
kA
kA
385
400
490
24,4
22,7
570
635
775
50,9
47,2
635
720
880
64,1
59,5
695
820
1010
83
75
0,16
0,75
1,4
Nominal values unless otherwise specified.
1) Cable distance, installation flat formation = 70 mm
2) Trefoil with screen grounded in both ends
Product Catalogue
Draka Keila Cables | 49
Power cables
AXQJ-F 14/24 kV
20 kV halogen-free power cable
Application fields
Material declaration
Halogen-free and fire classified single core cable. No
emittance of corrosive gases, low smoke density in case
of fire. Distribution cable for indoors and outdoors use
in 3-phase formation. Installation in pipes and ground.
Ploughing down is not recommended.
AXQJ-F, –RMF
Alternative designation
SE-N20XC7Z1-AR
Standard
SS 424 14 16
CENELEC HD 620 Part 5 Section K
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Fire propagation class
F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and
SS-EN 50266-2-3
Temperature range
In continuous operation max. conductor temp. . . . . 90˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken
Impulse voltage
125 kV
Bending radius
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Design
Conductor���������������������� stranded, round and compacted
aluminium acc. to IEC 60228
class 2, longitudinal water
sealed
Conductor screen���������� extruded
Insulation������������������������ XLPE, min. thickness = 4,85 mm
Insulation screen���������� extruded bonded
Concentric conductor���� annealed copper wires
Sheath���������������������������� halogen-free compound, black
Marking
E.g. AXQJ-F 14/24 kV 1x630/35 F4B FASTSITTANDE
SKIKT DRAKA SE “Date”, meter marked.
mm2
1x240/25
1x500/35
1x630/35
mm
mm
kg/100 m
m
30,3
38,1
175,5
500
K16
0071440
38,8
47,3
287,5
500
K20
0071470
42,9
51,5
338,1
500
K20
0071480
Inductance in trefoil/flat formation (1) (2)
Reactance
Capacitance
Charging current
Ω/km
Ω/km
mH/km
Ω/km
µF/km
A/km
0,125
0,8
0,34/0,59
0,19
0,29
1,1
0,0605
0,6
0,30/0,53
0,17
0,39
1,5
0,0469
0,6
0,29/0,51
0,16
0,43
1,6
0,0367
0,524
0,27
Electrical data
Current rating at core temp. 65˚C in ground (2)
Current rating at core temp. 65˚C in air (2)
Current rating at core temp. 90˚C in air (2)
Max. short circuit current on the conductor during 1 s at initial temp. 70˚C
Max. short circuit current on the conductor during 1 s at initial temp. 90˚C
A
A
A
kA
kA
385
400
490
24,4
22,7
570
635
775
50,9
47,2
635
720
880
64,1
59,5
695
820
1010
83,0
75,0
Number of cores x cross section of conductor
Diameter over insulation
Overall diameter (approx.)
Weight (approx.)
Standard delivery length
Standard drum size
Article number
Electrical data at +20˚C
Conductor resistance
Screen resistance
1x800/35
63
52
365
500
K22
0,75
1,9
Nominal values unless otherwise specified.
1) Cable distance, installation flat formation = 70 mm.
2) Trefoil with screen grounded in both ends.
50 | Draka Keila Cables
Product Catalogue
Power cables
PAS-W 20 kV
Covered conductor PAS-W 20 kV
Application
Construction
For pole installation as part of PAS-system.
SFS 5791, EN 50397
Conductor . . . . . . . round, stranded and compacted watertight aluminium alloy conductor
Covering. . . . . . . . . black weather resistant XLPE compound
Rated voltage
Marking
U0/U = 12/20 kV, Um = 24 kV
PAS, DRAKA, product name, year of manufacture, PEX.
Temperature range
Options
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . .80˚C
– in a short circuit (duration up to 5 s) . . . . . . . . . . 200˚C
Lowest recommended temperature during laying. . . –20˚C
PAS-W 30 kV is available by special order.
Standards
Basic cable data
PAS-W 35
6,9
11,5
90
160
PAS-W 50
8,0
12,7
120
200
PAS-W 70
9,7
14,3
180
270
PAS-W 95
11,3
16,1
245
350
PAS-W 120
12,8
17,6
310
425
PAS-W 150
14,2
18,9
385
510
2000
K11
375
2000
K11
455
2000
K12
630
2000
K14
815
2000
K16
1045
2000
K16
1215
m
m
kN
N/mm2
N/mm2
1/˚C
0,16
0,12
11,2
0,18
0,13
15,5
0,20
0,14
22,5
0,25
0,18
38
0,27
0,19
47,3
Ω/km
Ω/km
0,986
1,22
0,720
0,89
0,493
0,61
0,363
0,45
0,288
0,36
0,236
0,29
A
200
245
310
370
430
485
kA
3,2
4,3
6,4
8,6
11,0
13,5
Diameter over conductor (1)
Diameter over covered conductor (1)
aluminium
Weight (1)
cable
Delivery data
Standard delivery length
Drum
mm
mm
kg/km
kg/km
Total weight (1)
Mechanical data (2)
Min. permissible bending radius during laying
kg
Min. permissible bending radius at final installation (3)
Min. tensile strength of the conductor
Initial modulus of elasticity of conductor
Final modulus of elasticity of conductor
Coefficient of linear expansion of conductor
Electrical data (2)
Maximum DC resistance of conductor (20˚C)
AC resistance of conductor (80˚C) (1)
Current ratings (2)
In air (conductor 80˚C)
Short circuit currents (2)
Max. permissible short circuit current for 1 second (4)
m
0,22
0,16
30,4
61,000
62,500
23 x 10-6
1) Approximate value.
2) See the basic assumptions at general information of products.
3) Final installation with careful single bending.
4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C.
Product Catalogue
Draka Keila Cables | 51
Installation cables and wires
ELECTRICAL PROPERTIES
Current ratings for installation cables
(PVC insulated cables according to HD 21)
RATED VOLTAGE
The rated voltage of cables is marked U0/U, where:
U0 - rated voltage between the conductor and earth of metallic screen
U - rated voltage between conductors.
DIRECT CURRENT RESISTANCE OF CONDUCTORS
HD 516 table 7a
Cross section of conductors mm2 0,75 1,0 1,5 2,5 4 6 10 16 25
Current rating 2 cores load A
6
10 16 25 32 Current rating 3 cores load A
6
10 16 20 25 37 52 69 92
For each cable, the catalogue lists the maximum direct current resistance value for the conductor at a temperature of +20°C, permitted
by the construction standard. The current in a conductor heats up
the conductor. The rise in temperature increases the conductor’s
resistance. The following table shows some pre-calculated correction factors for the direct current resistance of copper conductor.
Assumptions for table are:
- conductor temperature in PVC cable . . . . . . . . . . . . . . 70˚C
- ambient air temperature . . . . . . . . . . . . . . . . . . . . . 30˚C
Conductor temperature
Correction factor
Maximum continuous current in amps for PVC insulated control
cables in air Uo/U=450/750 V.
°C
20
1,0
40
60
1,079 1,157
70
1,196
80
90
1,236 1,275
CABLES CURRENT CARRYING CAPACITY
Current carrying capacities of installation cables are given in
HD 384.5.523 (or IEC 364-5-523). Electrical installation of buildings
section 523: Current carrying capacities.
Current rating tables are based on the requirements of the maximum permissible conductor temperatures in continuous use and
assumed installation conditions. The correction factors must be
used when the conditions differ from the installation conditions
assumed in the current rating tables.
Current ratings for control cables
Number of conductors with load
Copper conductor cross section, mm2 0,75
1,5
2,5
4
20
7
8
13
16
12
7
11
13
19
6
9
11
27
5
8
10
37
4
7
9
48
4
6
-
Assumptions for table are:
- conductor temperature in PVC cable . . . . . . . . . . . . . . 70˚C
- ambient air temperature . . . . . . . . . . . . . . . . . . . . . 25˚C
THE NEW COLOURS OF WIRES FOR CABLES BY CENELEC HD 308 S2:2002 STANDARD
Renewed standard won’t bring substantial changes, yellow-green
remains for fuse wire (PE) or combined fuse- and neutral (PEN);
blue comes into use as the colour of the neutral wire (N) instead
of light blue. But the colours of phase wires will change – grey will
be taken into use in addition to black and brown. The sequence of
colours will change, too – instead of black, brown will be the first
colour of the phase wire.
PPJ
3 core (3X...)
PPJ
4 core (1,5 ja 2,5 mm2)
AXPK
PPJ
4 core (4–25 mm2)
PPJ
5 core
1
(A)MCMK
1
2
3
4 core
1
MCMK
3
5 core
4
(A)MCMK
2
MSK, MSO, MSOY 2 core
2
3 core
4
3
MSK, MSO, MSOY 3 core
1
PPJ
2 core
MSK, MSO, MSOY 4 core
PPJ
3 core (3G...)
MSK, MSO, MSOY 5 core
52 | Draka Keila Cables
Product Catalogue
Installation cables and wires
PL / ML / H07V-U
PVC-insulated solid conductor
Application
Temperature range
For fixed installation in a conduit, and for wiring in appliances, switchgear and control gear with a maximum
voltage of 1000 V (AC) or a maximum of 750 V (DC) to
earth.
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . –25˚C
Standards
Bending radius
EVS 719:1996, SFS 5523, CENELEC HD 21
During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
In a final installation if bent only once min.. . . . . . . . . . 3D
Certificate/approval
Construction
EEI, FI, <HAR>
Rated voltage
Conductor . . . . . . . . . . . annealed copper wire
Insulation . . . . . . . . . . . . . . PVC, core identification by colours
U0/U = 450/750 V
Identification of cores
PRU – brown, MU – black, SI – blue, KORO – yellow-green.
Cross section of
conductor and colour
PL 1,5 MU
PL 1,5 PRU
PL 1,5 SI
PL 1,5 KORO
PL 2,5 MU
PL 2,5 PRU
PL 2,5 SI
PL 2,5 KORO
PL 4 MU
PL 4 PRU
PL 4 SI
PL 4 KORO
Product Catalogue
EAN code
(SSTL code)
64 100+
04 012 03-1
04 012 02-4
04 012 07-9
04 012 09-3
04 012 23-9
04 012 22-2
04 012 27-7
04 012 29-1
04 012 43-7
04 012 42-0
04 012 47-5
04 012 49-9
Nominal overall
diameter
mm
2,7
2,7
2,7
2,7
3,3
3,3
3,3
3,3
3,9
3,9
3,9
3,9
Total weight
kg/km
20
20
20
20
31
31
31
31
50
50
50
50
Direct current resistance of
conductor at 20˚C max.
Ω/km
12,1
12,1
12,1
12,1
7,41
7,41
7,41
7,41
4,61
4,61
4,61
4,61
Standard delivery
length, coil
m
200
200
200
200
200
200
200
200
200
200
200
200
Draka Keila Cables | 53
Installation cables and wires
PK / MK / H07V-R
PVC-insulated stranded conductor
Application
Temperature range
For permanent installation in a conduit, and for wiring in
appliances, switchgear and control gear with a maximum
voltage of 1000 V (AC) or a maximum of 750 V (DC) to
earth.
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . –25˚C
Standards
Bending radius
EVS 718:1996, SFS 3103, CENELEC HD 21
During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
In a final installation if bent only once min.. . . . . . . . . . 3D
Certificate/approval
Construction
EEI, FI, <HAR>
Rated voltage
Conductor . . . . . . . . . . . annealed copper wires, stranded
Insulation . . . . . . . . . . . . PVC, core identification by colours
U0/U = 450/750 V
Identification of cores
RU, PRU – brown, MU – black,
KEVI, KORO – yellow-green, SI – blue
Cross section of con- EAN code
ductor and colour
(SSTL code)
64 100+
MK 1,5 RU
04 021 02-6
MK 1,5 MU
04 021 03-3
MK 1,5 SI
04 021 07-1
MK 1,5 KEVI
04 021 08-8
MK 2,5 RU
04 021 22-4
MK 2,5 MU
04 021 23-1
MK 2,5 SI
04 021 27-9
MK 2,5 KEVI
04 021 28-6
MK 4 MU
04 021 43-9
MK 4 SI
04 021 47-7
MK 4 KEVI
04 021 48-4
PK 6 MU
04 024 63-8
PK 6 SI
04 024 67-6
PK 6 KORO
04 024 69-0
PK 10 MU
04 024 73-7
PK 10 SI
04 024 77-5
PK 10 KORO
04 024 79-9
PK 16 MU
04 024 83-6
PK 16 SI
04 024 87-4
PK 16 KORO
04 024 89-8
PK 25 MU
04 024 91-1
PK 25 SI
04 024 96-3
PK 25 KORO
04 024 98-0
MK 35 MU
04 522 22-6
MK 35 SI
04 522 23-3
MK 35 KEVI
04 522 27-1
MK 50 MU
04 522 33-2
MK 50 SI
04 522 37-0
MK 50 KEVI
04 522 38-7
MK 70 KEVI
04 022 48-6
MK 95 KEVI
04 022 58-0
120 KEVI
04 022 66-5
54 | Draka Keila Cables
Nominal overall
diameter
mm
3
3
3
3
3,7
3,7
3,7
3,7
4,2
4,2
4,2
4,8
4,8
4,8
6,1
6,1
6,1
7,2
7,2
7,2
8,9
8,9
8,9
10
10
10
11,7
11,7
11,7
13,4
16
18
Total
weight
kg/km
22
22
22
22
35
35
35
35
52
52
52
70
70
70
115
115
115
175
175
175
270
270
270
370
370
370
510
510
510
710
1000
1200
Direct current resistance of
conductor at 20˚C max.
Ω/km
12,1
12,1
12,1
12,1
7,41
7,41
7,41
7,41
4,61
4,61
4,61
3,08
3,08
3,08
1,83
1,83
1,83
1,15
1,15
1,15
0,727
0,727
0,727
0,524
0,524
0,524
0,387
0,387
0.387
0.268
0.193
0.153
Standard delivery Standard delivery
length, coil
length, drum
m
250
250
250
250
200
200
200
200
150
150
150
100
100
100
100
100
100
100
100
100
100
100
100
500/6C
500/6C
500/6C
200/6C
200/6C
200/6C
200/6C
500/8E
800/11G
Product Catalogue
Installation cables and wires
MK 90 / H07V2-R
PVC-insulated stranded conductor
Application
Temperature range
For permanent installation in a conduit, and for wiring in
appliances, switchgear and control gear with a maximum
voltage of 1000 V (AC) or a maximum of 750 V (DC) to
earth.
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C
– in a short circuit (max.5 s) . . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . -25˚C
Standards
Bending radius
SFS 5523, CENELEC HD 21, IEC 60332-14
During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
In a final installation if bent only once min.. . . . . . . . . . 3D
Certificate/approval
Construction
FI, <HAR>
Conductor . . . . . . . annealed copper wires, stranded
Insulation . . . . . . . . lead-free Linyl PVC, core identification by colours
Rated voltage
U0/U = 450/750 V
Identification of cores
RU, PRU – brown, MU – black, KEVI – yellow-green, SI – blue
Cross section of con- EAN code
ductor and colour
(SSTL code)
64 100+
MK 1,5 RU
04 01704-3
MK 1,5 MU
04 01703-6
MK 1,5 SI
04 01705-0
MK 1,5 KEVI
04 01702-9
MK 2,5 RU
04 01708-1
MK 2,5 MU
04 01707-4
MK 2,5 SI
04 01709-8
MK 2,5 KEVI
04 01706-7
MK 4 MU
04 01711-91
MK 4 SI
04 01713-5
MK 4 KEVI
04 01710-4
PK 6 RU
04 01716-6
PK 6 MU
04 01715-9
PK 6 SI
04 01717-3
PK 6 KEVI
04 01714-2
PK 10 MU
04 01719-5
PK 10 SI
04 01720-3
PK 10 KEVI
04 01718-0
PK 16 MU
04 01722-7
PK 16 SI
04 01723-4
PK 16 KEVI
04 01721-0
PK 25 SI
04 02215-3
PK 25 KEVI
04 02216-0
MK 35 MU
04 52222-6
MK 35 SI
04 52223-3
MK 35 KEVI
04 52227-1
MK 50 MU
04 52233-2
MK 50 SI
04 52237-0
MK 50 KEVI
04 52238-7
MK 70 KEVI
04 022 48-6
MK 95 KEVI
04 022 58-0
120 KEVI
04 022 66-5
Product Catalogue
Nominal overall
diameter
mm
3
3
3
3
3,7
3,7
3,7
3,7
4,2
4,2
4,2
4,8
4,8
4,8
4,8
6,1
6,1
6,1
7,2
7,2
7,2
8,9
8,9
10
10
10
11,7
11,7
11,7
13,4
16
18
Total
weight
kg/km
22
22
22
22
35
35
35
35
52
52
52
70
70
70
70
115
115
115
175
175
175
270
270
370
370
370
510
510
510
710
1000
1200
Direct current resistance
of conductor at 20˚C max.
Ω/km
12,1
12,1
12,1
12,1
7,41
7,41
7,41
7,41
4,61
4,61
4,61
3,08
3,08
3,08
3,08
1,83
1,83
1,83
1,15
1,15
1,15
0,727
0,727
0,524
0,524
0,524
0,387
0,387
0,387
0,268
0,193
0,153
Standard delivery Standard delivery
length, coil
length, drum
m
250
250
250
250
200
200
200
200
150
150
150
100
100
100
100
100
100
100
100
100
100
100
100
500/6C
500/6C
500/6C
200/6C
200/6C
200/6C
200/6C
500/8E
800/11G
Draka Keila Cables | 55
Installation cables and wires
MKEM 90 / H07V2-K
PVC-insulated flexible conductor
Application
Construction
For fixed installation in a conduit, and for wiring in appliances, switchgear and control gear with a maximum voltage of 1000 V (AC) or a maximum of 750 V (DC) to earth.
Conductor . . . . annealed copper wires, stranded flexible
Insulation . . . . . lead-free Linyl PVC, core identification
by colours
Temperature range
Identification of cores
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C
– in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . -25˚C
RU – brown, MU – black, KEVI – yellow-green, SI – blue
Bending radius
Certificate/approval
During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
In a final installation if bent only once min. . . . . . . . . . 3D
FI, <HAR>
Standards
SFS 5523, CENELEC HD 21, IEC 60332-14
Rated voltage
U0/U = 450/750 V
Cross section of con- EAN code (SSTL
ductor and colour
code)
64 100+
1,5 RU
04 03102-5
1,5 MU
04 03103-2
1,5 SI
04 03107-0
1,5 KEVI
04 03108-7
2,5 RU
04 03122-3
2,5 MU
04 03123-0
2,5 SI
04 03127-8
2,5 KEVI
04 03128-5
4 MU
04 03143-8
4 SI
04 03147-6
4 KEVI
04 03148-3
6 MU
04 03163-6
6 SI
04 03167-4
6 KEVI
04 03168-1
10 MU
04 03183-4
10 SI
04 03187-2
10 KEVI
04 03188-9
16 MU
04 03203-9
16 SI
04 03207-9
16 KEVI
04 03208-9
25 MU
04 03213-8
25 SI
04 03217-6
25 KEVI
04 03218-3
35 MU
04 53223-2
35 SI
04 53227-0
35 KEVI
04 53228-7
50 MU
04 53233-1
50 SI
04 53237-9
50 KEVI
04 53238-6
70 MU
04 022 43-0
70 SI
04 022 47-8
70 KEVI
04 022 48-5
95 MU
04 03253-4
95 SI
04 03257-2
120 MU
04 032 63-3
150 MU
04 032 73-2
56 | Draka Keila Cables
Nominal overall
diameter
mm
3
3
3
3
3,6
3,6
3,6
3,6
4,1
4,1
4,1
5
5
5
6,5
6,5
6,5
7,6
7,6
7,6
9,4
9,4
9,4
11
11
11
13
13
13
15
15
15
17,5
17,5
19
22
Total weight Direct current resistance
of conductor at 20˚C max.
kg/km
Ω/km
21
13,3
21
13,3
21
13,3
21
13,3
32
7,98
32
7,98
32
7,98
32
7,98
45
4,95
45
4,95
45
4,95
70
3,3
70
3,3
70
3,3
115
1,91
115
1,91
115
1,91
170
1,21
170
1,21
170
1,21
270
0,78
270
0,78
270
0,78
370
0,554
370
0,554
370
0,554
520
0,386
520
0,386
520
0,386
730
0,272
730
0,272
730
0,272
940
0,206
940
0,206
1200
0,161
1450
0,129
Standard delivery Standard delivery
length, coil
length, drum
m
m
250
250
250
250
200
200
200
200
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
500/6C
500/6C
500/6C
200/6C
200/6C
200/6C
200/6C
200/6C
200/6C
200/7E
200/7E
200/7E
200/7E
Product Catalogue
Installation cables and wires
MMO
PVC sheated control cable
Application
Standards
Cables for control, measuring and signal circuits of
electrical equipment.
EVS 722:1996, SFS 3714; HD 627
Fixed surface or flush-mounted installations, indoors
and outdoors.
Direct sunlight may change the colour of the sheath.
EEI, FI
Rated voltage
U0/U=450/750 V
Temperature range
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . –15˚C
Construction
Conductor . . . . . . . annealed copper wires
Insulation . . . . . . . . black PVC, core identification by
numbers
Sheath . . . . . . . . . . white PVC, marked by meters
Number of conductors
and cross section
n x mm2
7x1,5
12x1,5
19x1,5
27x1,5
37x1,5
7x2,5
12x2,5
19x2,5
Certificate/approval
EAN code (SSTL
code)
64 100+
04 112 03-8
04 112 05-2
04 112 07-6
04 120 25-5
04 120 26-2
04 112 13-7
04 112 15-1
04 112 17-5
Nominal overall
diameter
mm
12
15
18
21
24
14
18
21
Bending radius
During installation min. . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
In a final installation if bent only once min.. . . . . . . . . . 3D
Identification of cores
Core identification by numbers.
Total weight
kg/km
230
350
500
700
950
310
500
750
Direct current resistance of
conductor at 20˚C max.
Ω/km
12,1
12,1
12,1
12,1
12,1
7,41
7,41
7,41
Standard delivery
length, drum
m
1000/K8
500/K8
500/K9
500/K11
500/K11
500/K8
500/K8
500/K11
Nominal values unless otherwise specified.
Product Catalogue
Draka Keila Cables | 57
Installation cables and wires
EKLK 450/750 V
Installation cable
Application fields
Temperature range
Fixed installation, indoors and outdoors, in pipes, ducts,
in or under plaster, also suspended in catenary system.
In ground, only if the cable is protected against mechanical damage.
In continuous operation max. conductor temp . . . . . 70˚C
Lowest cable temperature under installation . . . . . .-15˚C
and below 0˚C special precaution shall be taken.
Alternative designation
Bending radius
12D (6D in final installation, bent only once)
SE-N07VA5EV-U
Design
Standard
Halogen-free alternative
Conductor . . . . . . . solid and annealed copper acc. to
IEC 60228 class 1
Insulation . . . . . . . . lead-free PVC
Filler . . . . . . . . . . . . lead-free PVC
Concentric conductor . aluminium with bonded PVC in contact with drain wire of tinned copper
Inner sheath . . . . . PE, white
Sheath . . . . . . . . . . lead-free PVC, white, meter marked
EQLQ
Identification of cores
Approval
Material declaration
2-core . . . . . . . . . . . blue, brown
3-core . . . . . . . . . . . green/yellow, blue, brown
4-core . . . . . . . . . . . . green/yellow, blue, brown, black
5-core . . . . . . . . . . . green/yellow, blue, brown, black, grey
EKLK
Marking
SS 424 02 19-4
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1 and
SS-EN 50265-2-1
SEMKO, CE
E.g. EKLK 3G1,5 S BLYFRI F3 DRAKA SE.
Number of cores x cross section of conductor
mm2
Without earth conductor
2x1,5
2x1,5
With earth conductor
3G1,5
3G1,5
3G1,5
3G1,5
3G2,5
3G2,5
3G2,5
3G2,5
4G1,5
4G1,5
4G1,5
4G2,5
4G2,5
5G1,5
5G1,5
5G1,5
5G1,5
5G2,5
5G2,5
5G2,5
5G2,5
58 | Draka Keila Cables
Overall diameter
(approx.)
mm
Weight (approx.)
Standard delivery
length m
Standard drum
size/Package
Article number
10
10
14,3
14,3
50
500
Ring
K6
423101
423105
9,8
9,8
9,8
9,8
11,6
11,6
11,6
11,6
10,8
10,8
10,8
13,1
13,1
11,8
11,8
11,8
11,8
13,9
13,9
13,9
13,9
14
14
14
14
21,3
21,3
21,3
21,3
19
19
19
25,7
25,7
22,5
22,5
22,5
22,5
30,9
30,9
30,9
30,9
50
250
500
1000
50
150
500
1000
50
200
500
50
500
50
150
500
1000
50
150
500
1000
Ring
K4
K6
K7
Ring
K4
K6
K8
Ring
K4
K6
Ring
K7
Ring
K4
K7
K9
Ring
K4
K7
K9
423001
423003
423005
423006
423011
423013
423015
423016
423021
423023
423025
423031
423035
423041
423043
423045
423046
423051
423053
423055
423056
kg/100 m
Product Catalogue
Installation cables and wires
PPJ
PVC sheathed installation cable
Application
Bending radius
For fixed surface or flush-mounted installations, indoors
and outdoors. Suitable for installation in a slot covered
with plaster. Not for installation directly in ground or
directly in concrete without protective ducting. Cable
needs protection from direct sunlight.
Recommended during installation min. . . . . . . . . . . . . 10D
In a final installation if bent only once min . . . . . . . . . . 3D
Standards
Conductor . . . . . . . annealed copper wires; 1,5 – 4 mm2
solid and 6 – 25 mm2 stranded
Insulation . . . . . . . . PVC, core identification by colours
Filling . . . . . . . . . . . filling compound
Sheath . . . . . . . . . . white PVC, marked by meters
EVS 720:1996, EVS 721:1996, SFS 2091, SFS 5524
Identification of cores
Certificate/approval
Core identification according to the HD 308 S2:2002
EEI, FI, CE
X type without green/yellow core
Rated voltage
2-core . . . . . . . . . . . . . . . . blue, brown
3-core . . . . . . . . . . . . . . . . brown, black, grey
Max. permissible tensile stress
during installation . . . . . . . . . . . . . . . . . . . . . .Ax50 N/mm2
U0/U=300/500 V (1,5–4 mm2), U0/U=450/750 V
(6–25 mm2)
Temperature range
Highest permissible conductor temperature
– in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C
– in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 160˚C
Lowest recommended handling temperature . . . . . –15˚C
Number of
EAN code
conductors and (SSTL code)
cross section
reel
64 100+
n x mm2
Without protective conductor
2x1,5
04 073 12-4
3x1,5
04 073 22-3
2x2,5
04 073 13-1
With protective conductor
3G1,5
04 072 22-6
4G1,5
04 072 32-5
5G1,5
04 072 42-4
3G2,5
04 072 23-3
4G2,5
04 072 33-2
5G2,5
04 072 43-1
3G4
4G4
5G4
3G6
4G6
5G6
4G10
5G10
4G16
5G16
4G25
5G25
Product Catalogue
Construction
EAN code
(SSTL code)
drum
04 572 22-1
04 572 32-0
04 072 42-9
04 572 23-8
04 572 33-7
04 572 43-6
04 572 24-5
04 572 34-4
04 572 44-3
04 572 25-2
04 572 35-1
04 572 45-0
04 572 36-8
04 572 46-7
04 572 37-5
04 572 47-4
04 572 38-2
04 572 48-1
Nominal
overall
diameter
mm
G type with green/yellow core
3-core . . . . . . . . . . . . . . . . green/yellow, blue, brown
4-core (1,5 and 2,5 mm2) . green/yellow, blue, brown,black
4-core (4–25 mm2). . . . . . . green/yellow, brown, black, grey
5-core . . . . . . . . . . . . . . . . green/yellow, blue, brown,
black, grey
Total
weight
kg/km
Direct current resistance of conductor at
20˚C max
Ω/km
Standard
delivery
length, reel
m
8
9
10
105
125
150
12,1
12,1
7,41
100
100
100
9
10
10
10
11
12
10
12
13
14
16
17
19
21
22
24
30
31
125
155
180
180
220
260
280
340
410
350
430
510
670
810
950
1150
1780
1900
12,1
12,1
12,1
7,41
7,41
7,41
4,61
4,61
4,61
3,08
3,08
3,08
1,83
1,83
1,15
1,15
0,727
0,727
100
100
50
100
50
50
Standard
delivery
length, drum
m
2000
1000
1000
1000
1000
750
1000
750
500
500
500
500
400
250
250
250
250
250
Draka Keila Cables | 59
Installation cables and wires
MSK / H05VV-F
Flexible cord
Application
Bending radius
Cord for ordinary duty use for portable appliances in
domestic premises, kitchens and offices.
- For household appliances in dry and damp premises.
- Not for outdoor use, industrial use, agricultural use.
Min. recommended bending radius in normal usage. . . 6D
Construction
Conductor��������������Annealed copper wires, stranded,
flexible
Insulation����������������PVC, core identification by colours
Sheath��������������������PVC, round
The weight of a lighting fixture hanging from the cable
must not exceed 2 kg.
Standard
Identification of cores
SFS 5525 = CENELEC HD 21
N type without green/yellow core. . . . . . . . . . . . . . . 2-core
S type with green/yellow core. . . . . . . . . . . . . . . . . BU – BN
3-core. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GNYE – BU – BN
4-core. . . . . . . . . . . . . . . . . . . . . . . . . . GNYE – BK – BU – BN
5-core. . . . . . . . . . . . . . . . . . . . . . GNYE – BK – BU – BN – BK
Certificate/approval
FI (FIMKO), CE, <HAR>
Rated voltage
U0/U = 300/500 V
Temperature range
Maximum permissible temperature of conductor:
– in continuous use . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60˚C
- in a short circuit (max. 5 s) . . . . . . . . . . . . . . . . . . . 150˚C
Lowest recommended handling temperature. . . . . . . 15˚C
Number of conductors and EAN code (SSTL
cross section
code)
64 100+
With protective conductor
3 x 0,75 S
04 197 20-2
3 x 1,0 S
04 197 21-9
3 x 1,5 S white
04 197 22-6
3 x 1,5 S grey
04 198 22-3
4 x 0,75 S
04 197 30-1
4 x 1,5 S
04 197 32-5
5 x 1,0 S
04 197 41-7
5 x 1,5 S
04 197 42-4
Without protective conductor
2 x 0,75 N
04 194 10-2
2 x 1,0 N
04 194 11-9
2 x 1,5 N
04 194 12-6
Nominal overall Total weight
diameter
mm
kg/km
Direct current resistance of Standard delivery
conductor at +20˚C max.
length coil
Ω/km
m
6,6
7
8,3
8,3
7,2
9,3
8,6
10,3
65
72
100
100
75
130
110
160
26
19,5
13,3
13,3
26
13,3
19,5
13,3
100
100
100
100
100
100
100
100
6,2
6,6
7,6
52
60
80
26
19,5
13,3
100
100
100
Abbreviations of colours
VA = WH White
HA = GY Grey
60 | Draka Keila Cables
Product Catalogue
Installation cables and wires
PROFIT
Conduit with cores
Application
Properties of cables and cores as without conduit.
For fixed installation in electrical- and information network.
Conduit is suitable for installation in concrete
Current carrying capacities of ML/MK/MKZ according to
HD 384.5.523 (or IEC 364-5-523): “Electrical installation
of buildings” section 523: Current carrying capacities.
Standards
Conduit EN 50086, cables and wires have own
Conduit. . . . . . . . . . Flexible PP conduit, lead-free, ICTA 3342
Certificates
CE, RoHS
Properties
Self-extinguishing
Maximum permissible temperature of conduit
in use and installation . . . . . . . . . . . . . . . . . . . . . . . . . .90˚C
Minimum permissible temperature of conduit
in installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –25˚C
Compression resistance . . . . . . . . . . . . . . . 750 N (ICTA 3)
Impact resistance . . . . . . . . . . . . . . . 2 kg/100 mm (ICTA 3)
Convenient installation without twists
Multi-installation base ensure uncoiled and smooth
running of the cable from the package.
SSTL code 64 070 09
Product Catalogue
Construction
Cables and cores
PROFIT ML. . . . . . . H07V-U cores in Ø16/20 conduit
PROFIT MK . . . . . . H07V-R cores in Ø16/20 conduit
PROFIT MKZ . . . . . H07V-R cores in Ø16/20 conduit,
wires twisted together
PROFIT CAT 5e . . . CAT 5e UTP in Ø20 conduit
PROFIT CAT 6 . . . . CAT 6 UTP in Ø20 conduit
PROFIT TELLU 13 . . TELLU 13 in Ø16 conduit
PROFIT MHS . . . . . MHS in Ø16 conduit
ML(H07V-U), MK(H07V-R), MKZ colours according to
HD 308 S2
Name
SSTL code
PROFIT MK 3x1.5 S 16/R100
PROFIT MK 3x2.5 S 16/R100
PROFIT MK 3x4 S 20/R50
PROFIT MK 4x1.5 S 16/R100
PROFIT MK 4x2.5 S 20/R50
PROFIT MK 5x1.5 S 20/R50
PROFIT MK 5x2.5 S 20/R50
PROFIT MK 6 KEVI 16/R100
PROFIT MK 7x1.5 S 20/R50
PROFIT ML 3x1.5 N 16/R100
PROFIT ML 3x1.5 S 16/R100
PROFIT ML 3x2.5 S 16/R100
PROFIT ML 4x1.5 S 16/R100
PROFIT ML 5x1.5 N 16/R100
PROFIT ML 5x1.5 S 16/R100
PROFIT ML 5x2.5 S 20/R100
PROFIT ML 7x1.5 S 20/R100
PROFIT CAT 5e UTP 2x4p 20/R100
PROFIT CAT 6 UTP 2x4p 20/R100
PROFIT TELLU 13 16/R100
PROFIT MHS 3x2x0,5 16/R100
04 123 02
04 123 04
04 017 34
04 123 06
04 017 42
04 123 08
04 123 10
04 123 12
04 011 30
04 011 32
04 011 34
04 011 36
04 011 38
04 011 40
04 011 41
04 017 71
02 413 12
02 413 14
02 321 78
02 024 07
Total weight
kg/km
110
145
210
130
190
165
225
115
205
105
105
140
125
160
160
215
195
130
140
105
85
Coil length m Pallet length
m
100
100
50
100
50
50
50
100
50
100
100
100
100
100
100
100
100
100
100
100
100
1800
1800
900
1800
900
900
900
1800
900
1800
1800
1800
1800
900
900
900
900
900
900
1800
1800
Draka Keila Cables | 61
Automation, data and telecommunication cables
JAMAK
Instrumentation cable
Applications
Identification
• Fixed indoor installations
• Automation
• Instrumentation
• Process control
• Audio systems
• Suitable for MaxiTermipoint connections
Units marked with numbers, a-conductors are blue and
b-conductors are red.
Construction
Conductor . . . . . . . stranded tinned copper
Insulation . . . . . . . . PE
Unit . . . . . . . . . . . . . twisted and individually with, plasticaluminium tape shielded pair, earth
conductor and a number tape
Shield . . . . . . . . . . . plastic aluminium tape with earth
conductor
Sheath . . . . . . . . . . grey Linyl PVC
Number and size of the conductor
EAN code (SSTL code)
Nominal diameter
Mass
Delivery length
Drum
Electrical properties 20˚C
Maximum loop resistance
Nominal mutual capacitance (800 Hz)
Impedance, 10 MHz
Minimum insulation resistance
Velocity factor
Maximum voltage
Nominal attenuation
frequency 9,6 kHz
frequency 19,2 kHz
frequency 64 kHz
frequency 100 kHz
frequency 200 kHz
frequency 1,0 MHz
Other properties
Bending radius
during installation, min.
(D=outer diameter)
during operation, min.
Installation temperature min.
Max operation temperature
62 | Draka Keila Cables
mm2
64 100+
mm
kg/km
m
Ω/km
µF/km
Ω
GΩ x km
V
dB/100 m
dB/100 m
dB/100 m
dB/100 m
dB/100 m
dB/100 m
mm
mm
˚C
˚C
2 x(2+1)x 0,5
02 642 52-0
8
70
1000
K6
4 x(2+1)x 0,5
02 642 54-4
9,5
110
1000
K7
8 x(2+1)x 0,5
02 642 58-2
13
200
1000
K9
12 x(2+1)x 0,5
02 642 62-9
15
280
1000
K10
24 x(2+1)x 0,5
02 642 64-3
21
530
1000
K12
48 x(2+1)x 0,5
02 642 68-1
29
990
500
K12
81
85
70 ± 10 %
2
0,66
75
0,3
0,5
0,7
0,9
1,6
4,5
15D
10D
–5
70
Product Catalogue
Automation, data and telecommunication cables
JAMAK ARM
Instrumentation cable
Applications
Construction
• Fixed outdoor installations
• Automation
• Instrumentation
• Process control
• Audio systems
• Suitable for MaxiTermipoint connections
Conductor . . . . . . . stranded tinned copper
Insulation . . . . . . . . PE
Unit . . . . . . . . . . . . . twisted and individually with plasticaluminium tape shielded pair,
earth conductor and a number tape
Shield . . . . . . . . . . . plastic/aluminium tape with earth
conductor
Sheath . . . . . . . . . . grey Linyl PVC
Armouring . . . . . . . wrapped steel band
Outer sheath . . . . black PE
Suitable specially for digital and low level analog signal
transmission. The construction gives an excellent protection against electromagnetic interference.
Identification
Units marked with number tape, a-conductors are blue
and b-conductors are red.
Other properties
JAMAK ARM is also available as halogen-free (JAMAK
ARM-HF)
Number and size of the conductor
EAN code (SSTL code)
Nominal diameter
Mass
Delivery length
Drum
Electrical properties 20˚C
Maximum loop resistance
Nominal mutual capacitance (800 Hz)
Impedance, 10 MHz
Minimum insulation resistance
Velocity factor
Maximum voltage
Nominal attenuation
frequency 9,6 kHz
frequency 19,2 kHz
frequency 64 kHz
frequency 100 kHz
frequency 200 kHz
frequency 1,0 MHz
Other properties
during installation, min.
Bending radius (D=outer diameter)
during operation, min.
Installation temperature min.
Max operation temperature
Product Catalogue
mm2
64 100+
mm
kg/km
m
Ω/km
µF/km
Ω
GΩ x km
V
dB/100 m
dB/100 m
dB/100 m
dB/100 m
dB/100 m
dB/100 m
mm
mm
˚C
˚C
4 x (2+1) x 0,5
02 642 72-4
14
240
1000
K9
8 x (2+1) x 0,5
02 642 78-0
17
370
1000
K11
12 x (2+1) x 0,5
02 642 82-7
19
480
1000
K11
24 x (2+1) x 0,5
02 642 84-1
25
820
1000
K14
48 x (2+1) x 0,5
02 642 88-9
33
1440
500
K18
81
85
70 ± 10 %
2
0,66
75
0,3
0,5
0,7
0,9
1,6
4,5
15D
10D
-5
70
Draka Keila Cables | 63
Automation, data and telecommunication cables
NOMAK
Instrumentation cable
Application
Identification
• Fixed indoor installations
• Automation
• Instrumentation
• Process control
• Suitable for Maxi Termipoint connections
Pairs marked with numbers, a-conductors are orange
and b-conductors are white.
Construction
Conductor . . . . . . . stranded tinned copper
Insulation . . . . . . . PVC
Unit . . . . . . . . . . . . twisted pair
Overall shield . . . . plastic/aluminium tape with earth
conductor
Sheath . . . . . . . . . . grey Linyl PVC
Number and size of the conductor
EAN code (SSTL code)
Nominal diameter
Mass
Delivery length
Drum
Electrical properties 20˚C
Maximum loop resistance
Nominal mutual capacitance (800 Hz)
Impedance, 10 MHz
Minimum insulation resistance
Velocity factor
Maximum voltage
Nominal attenuation frequency 9,6 kHz
frequency 19,2 kHz
frequency 64 kHz
frequency 100 kHz
frequency 200 kHz
frequency 1,0 MHz
Other properties
Bending radius
during installation, min.
(D – outer diameter)
during operation, min.
Installation temperature min.
Max operation temperature
64 | Draka Keila Cables
n x n mm2
64 100+
mm
kg/km
m
2 x 2 x 0,5
02 649 52-9
7,5
55
1000
K6
4 x 2 x 0,5
02 649 54-3
9
85
1000
K6
8 x 2 x 0,5
02 649 58-1
12
150
1000
K7
Ω/km
µF/km
Ω
81
90
81
90
81
85
GΩ x km
V
dB/100 m
dB/100 m
dB/100 m
dB/100 m
dB/100 m
dB/100 m
mm
mm
˚C
˚C
12 x 2 x 0,5
02 649 62-8
13
210
1000
K9
81
85
100 ± 10 %
100
0,6
75
0,3
0,5
0,7
0,9
1,5
2,9
24 x 2 x 0,5
02 649 64-2
18
400
1000
K11
48 x 2 x 0,5
02 649 68-0
24
720
1000
K14
81
85
81
85
15D
10D
-5
70
Product Catalogue
Automation, data and telecommunication cables
KLMA
Signal cable
Applications
Identification
• Fixed indoor installations
• Building automation
• Alarm, signal and security control transmission
1. conductor . . . . . . . . . .
2. conductor . . . . . . . . .
3. conductor . . . . . . . . .
4. conductor . . . . . . . . .
Construction
According to . .
Conductor . . . .
Insulation . . . . .
Unit . . . . . . . . .
SFS 2755
tinned copper
PVC
twisted conductors shielded with
plastic/aluminium tape,earth conductor
Sheath . . . . . . . grey Linyl PVC
Number and size of the conductor
EAN code (SSTL code)
Nominal diameter
Mass
Delivery length
Electrical properties 20˚C
Maximum loop resistance
Minimum insulation resistance
Maximum voltage
Other properties
Bending radius (D=outer diameter)
Installation temperature min.
Max operation temperature
Product Catalogue
blue
yellow
white
red
Other properties
KLMA is also available as halogen-free KLMA-LSZH
version
n x mm
64 100+
mm
kg/km
m
2 x 0,8 + 0,8
02 920 01-7
5
30
500
4 x 0,8 + 0,8
02 920 03-1
5,5
45
500
Ω/km
GΩ x km
V
36,7
500
75
36,7
500
75
15D
10D
–5
70
15D
10D
–5
70
during installation, min. mm
during operation, min. mm
˚C
˚C
Draka Keila Cables | 65
Automation, data and telecommunication cables
PULS 2,5 75V
Traffic sensor cable
Application
Temperature range
Traffic light cable with a maximum voltage of 75 V (AC)
or a maximum of 50 V (DC) to earth.
Highest permissible conductor temperature
- in continuous operation . . . . . . . . . . . . . . . . . . . . . . .90˚C
- in a short circuit (max. 30 s) . . . . . . . . . . . . . . . . . 200˚C
Lowest recommended handling temperature . . . . . –40˚C
Standards
IEC 60228, CENELEC HD 22, IEC 60332-1
Certificate/approval
RoHS
Rated voltage
Construction
Conductor . . . . . . . annealed tinned copper wires,
stranded flexible
Insulation . . . . . . . . heat resistant plastic
Outer sheath . . . . . black oil retardant rubber
U = 75 VDC; 50 VAC
Bending radius
During installation . . . . . . . . . . . . . . . . . . . . . . . . . . . min 3D
Cross section of conductor and colour
EAN code (SSTL code)
Nominal overall diameter
Total weight
Direct current resistance of conductor at 20˚C max.
Minimum recommended bending radius during installation
Standard delivery length
Reel
66 | Draka Keila Cables
64 100+
mm
kg/km
Ω/km
m
m
PULS 2,5 MU 75 V
0231002
4
30
8,21
0,012
1000
S4
Product Catalogue
Automation, data and telecommunication cables
MHS
Indoor telecommunication cable
Construction
Conductor . . . . . . . annealed, tinned copper wire
Insulation . . . . . . . . PE
Twinning. . . . . . . . . two insulated conductors in a pair
Lay-up . . . . . . . . . . stranded into units
Signal wire . . . . . . . red, insulated conductor
Ground wire . . . . . . annealed, tinned copper wire
Screen . . . . . . . . . . plastic coated aluminium foil
Sheath . . . . . . . . . . grey Linyl PVC
Electric properties (+20˚C)
Loop resistance
maximum
maximum average
Insulation resistance
minimum 500 V, 1 min.
Mutual capacitance
maximum
maximum average
Capacitance unbalance
maximum
over 30-pair cables, 95 % of values
Conductor number and
diameter
mm
1 x 4 x 0,5
drum
coil
coil
3 x 2 x 0,5
drum
coil
5 x 2 x 0,5
drum
coil
10 x 2 x 0,5
drum
coil
20 x 2 x 0,5
drum
coil
30 x 2 x 0,5
50 x 2 x 0,5
100 x 2 x 0,5
200 x 2 x 0,5
400 x 2 x 0,5
800 x 2 x 0,5
Product Catalogue
EAN code
Nominal sheath
thickness
64 100+
mm
1,0
192 Ω/km
184 Ω/km
500 MΩkm
65 µF/km
60 µF/km
250 pF/500 m
150 pF/500 m
Nominal outer
diameter
mm
4,5
Nominal
mass
kg/km
30
02 951 31-8
02 551 21-1
02 551 31-0
1000
100
300
1,0
5,0
36
02 951 32-5
02 551 32-7
1000
200
1,0
6,0
50
02 951 33-2
02 551 33-4
1000
150
1,0
7,6
78
02 551 34-1
02 551 35-8
02 551 36-5
02 551 39-6
02 551 37-2
02 551 38-9
02 551 40-2
02 551 42-6
02 551 44-0
02 551 48-8
Standard delivery
length
m
1000
200
1,0
9,5
130
1,1
1,1
1,2
1,5
1,8
2,2
11,5
14,0
19,0
26,0
36,0
50,0
185
285
550
1030
2000
3950
1000
150
1000
1000
1000
1000
500
500
Draka Keila Cables | 67
Automation, data and telecommunication cables
VMOHBU
Outdoor telecommunication cable
Construction
Conductor . . . . . . . annealed copper wire
Insulation . . . . . . . . PE
Twinning. . . . . . . . . two insulated conductors in a pair
Signal wire . . . . . . . red, insulated conductor
Filling compound. . special jelly
Screen . . . . . . . . . . aluminium laminate
Sheath . . . . . . . . . . black PE
Electric properties (+20˚C)
Number of pairs in cable
Mutual capacitance maximum
Mutual capacitance max average
µF/km
µF/km
Diameter of conductor
Resistance unbalance maximum
mm
%
0,8
Diameter of conductor
Loop resistance max
Loop resistance max average
mm
Ω/km
Ω/km
0,4
300
288
Insulation resistance 500 V, 1 min
Minimum
GΩ km
2
Diameter of Capacitance unbalance
conductor pair-to pair
maximum
95% of values
pF/500 m
pF/500 m
mm
0,4-0,6
250
150
0,8
180
100
68 | Draka Keila Cables
50 and more less than 50
45
46
40
–
2
0,5
192
184
0,6
134
128
0,8
74
71
Capacitance unbalance
pair-to-earth
maximum
95% of value
pF/500 m
pF/500 m
1700
1000
Conductor
number and
diameter
mm
100 x 2 x 0,4
200 x 2 x 0,4
300 x 2 x 0,4
400 x 2 x 0,4
600 x 2 x 0,4
800 x 2 x 0,4
1200 x 2 x 0,4
3 x 2 x 0,5
5 x 2 x 0,5
10 x 2 x 0,5
20 x 2 x 0,5
30 x 2 x 0,5
50 x 2 x 0,5
100 x 2 x 0,5
200 x 2 x 0,5
300 x 2 x 0,5
400 x 2 x 0,5
600 x 2 x 0,5
800 x 2 x 0,5
5 x 2 x 0,6
10 x 2 x 0,6
20 x 2 x 0,6
30 x 2 x 0,6
50 x 2 x 0,6
100 x 2 x 0,6
200 x 2 x 0,6
300 x 2 x 0,6
400 x 2 x 0,6
10 x 2 x 0,8
20 x 2 x 0,8
30 x 2 x 0,8
50 x 2 x 0,8
100 x 2 x 0,8
3 x 2 x 1,0
EAN code
64 100+
02 565 08-9
02 565 09-6
02 565 11-9
02 565 12-6
02 565 13-3
02 565 14-0
02 565 16-4
02 563 21-4
02 564 74-7
02 564 75-4
02 564 76-1
02 564 77-8
02 564 78-5
02 564 79-2
02 564 80-8
02 564 81-5
02 564 82-2
02 564 83-9
02 564 84-6
02 565 43-0
02 565 44-7
02 565 45-4
02 565 46-1
02 565 47-8
02 565 48-5
02 565 62-1
02 565 63-8
02 565 64-5
02 565 50-8
02 565 51-5
02 565 52-2
02 565 53-9
02 565 54-6
02 565 03-4
Nominal
sheath
thickness
mm
2,2
2,4
2,6
2,6
2,8
3
3
2
2
2
2
2
2
2,2
2,4
2,4
2,6
3
3,2
2
2
2
2
2
2,2
2,6
2,6
2,6
2
2
2
2,2
2,4
2
Nominal
outer
diameter
mm
24
33
38
43
52
58
71
9,7
11
12,5
15,5
17,5
22
28
39
45
52
62
71
12
14
17,5
21
25
33
46
54
63
16,5
22
25
32
42
14
Nominal
cable
mass
kg/km
600
1150
1600
2100
3000
3850
5700
80
105
145
235
315
480
860
1650
2350
3050
4500
5900
130
185
305
425
630
1200
2300
3300
4400
275
480
680
1100
2000
185
Standard
delivery
length
m
1000
1000
1000
1000
500
500
500
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
1000
1000
1000
1000
1000
1000
1000
500
500
1000
1000
1000
1000
1000
1000
Product Catalogue
Automation, data and telecommunication cables
H05RN-F; RDO/05RN-F 300/500 V
Rubber cable
Application fields
Bending radius
A highly flexible weather resistant cable, for the connection of light portable equipment where the risk
of mechanical stress is low. Suitable for permanent
outdoor use.
During installation . . . . . . . . . . . . . . . . . . . . . . . . . . . min 6D
Standard
SS 424 02 35, CENELEC HD 22.4
Design
Conductor. . Flexible and annealed copper acc. to
IEC 60228 class 5
Insulation . . EPDM-rubber
H05-, H07RN-F, RDO/05RN-F
Core identification
2-core . . . . . blue, brown
3-core . . . . . green/yellow, blue, brown
4-core . . . . . green/yellow, brown, black, grey
5-core . . . . . green/yellow, blue, brown, black, grey
7-core . . . . . green/yellow, 6 cores black number-marked 1-6
Sheath . . . . weather and oil resistant Bjuroflex rubber
Approval
Marking
H05RN-F . . . . . . . . <HAR>, C
RDO/05RN-F . . . . . SEMKO, C
E.g. DRAKAFLEX SEMKO <HAR> H05RN-F 2X1.
Fire propagation class
F2 acc. to SS 424 14 75 and IEC 60332-1
Material declaration
Temperature range
In continuous operation max. conductor temp . . . . .60˚C
The cable is flexible down to . . . . . . . . . . . . . . . . . . . –25˚C
Number of cores x cross
section of conductor
mm2
H05RN-F
2x0,75
2x0,75
2x1
2x1
3G0,75
3G0,75
3G1
3G1
RDO/05RN-F
2x1,5
2x1,5
3G1,5
3G1,5
3G2,5
3G2,5
4G1,5
4G1,5
4G2,5
4G2,5
5G1,5
5G1,5
5G2,5
5G2,5
7G1,5
Product Catalogue
Overall diameter
(approx.)
mm
Weight
(approx.)
kg/100 m
Standard
delivery length
m
Standard
drum size/package
Article number
6,3
6,3
6,9
6,9
6,9
6,9
7,3
7,3
6
6
7,1
7,1
7,7
7,7
8,8
8,8
100
500
100
500
100
500
100
500
Coil
K6
Coil
K6
Coil
K6
Coil
K6
952002040202
952002040205
952002070202
952002070205
952003040202
952003040205
952003070202
952003070205
8,3
8,3
9
9
10,5
10,5
9
9
11,8
11,8
11,2
11,2
13
13
12,6
10,4
10,4
12,1
12,1
17
17
15,1
15,1
21,2
21,2
18,3
18,3
26,1
26,1
24,1
100
500
100
500
50
500
50
500
50
500
50
500
50
500
500
Coil
K6
Coil
K6
Coil
K6
Coil
K6
Coil
K7
Coil
K6
Coil
K7
K7
952002080202
952002080205
952003080202
952003080205
952003100201
952003100205
952004080201
952004080205
952004100201
952004100205
952005080201
952005080205
952005100201
952005100205
952007080205
Draka Keila Cables | 69
Automation, data and telecommunication cables
DRAKAFLEX H07RN-F 450/750 V
Rubber cable
Application fields
Bending radius
A highly flexible weather and oil resistant cable. For use
where the mechanical stress have medium hard character, in spaces with explosion risks or dry and damp
spaces. Outdoors e.g. in agricultural buildings and for
temporary installations in working sites. Also for fixed
installation in temporary buildings and cabins.
When flexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6D
At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4D
Standard
CENELEC HD 22.4
Fire propagation class
F2 acc. to SS 424 14 75 and IEC 60332-1
Approval
<HAR>, CE
Material declaration
H05-, H07RN-F, RDO/05RN-F
Temperature range
In continuous operation max. conductor temp. . . . .60˚C
The cable is flexible down to . . . . . . . . . . . . . . . . . . . –25˚C
70 | Draka Keila Cables
Max tensile stress (N)
Total copper area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x 15
Design
Conductor . . flexible and annealed copper acc. to
IEC 60228 class 5
Insulation . . EPDM-rubber
Identification of cores
2-core . . . . .
3-core . . . . .
4-core . . . . .
5-core . . . . .
7-core . . . . .
blue, brown;
green/yellow, blue, brown;
green/yellow, brown, black, grey;
green/yellow, blue, brown, black, grey;
green/yellow, 6 cores black numbermarked 1-6;
Sheath . . . . weather and oil resistant Bjuroflex rubber
Marking
E.g. DRAKAFLEX SEMKO <HAR> H07RN-F 5G1,5
Product Catalogue
Automation, data and telecommunication cables
DRAKAFLEX H07RN-F 450/750 V
Rubber cable
Number of cores x cross
section of conductor mm2
2x1
2x1
2x1,5
2x1,5
2x2,5
2x2,5
3G1
3G1
3G1,5
3G1,5
3G1,5
3G2,5
3G2,5
3G2,5
3G4
3G6
4G1,5
4G1,5
4G1,5
4G2,5
4G2,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G120
5G1,5
5G1,5
5G1,5
5G2,5
5G2,5
5G2,5
5G4
5G4
5G6
5G6
5G10
5G16
5G35
7G1,5
7G2,5
Product Catalogue
Overall diameter
(approx.) mm
8,3
8,3
8,9
8,9
10,7
10,7
8,8
8,8
9,6
9,6
9,6
11,5
11,5
11,5
14
15,2
10,5
10,5
10,5
12,4
12,4
12,4
14,9
16,5
22,7
26
32
35
41
47
53
58
11,7
11,7
11,7
13,5
13,5
13,5
16,9
16,9
18,7
18,7
25,5
28,3
39
15,1
17,4
Weight (approx.)
kg/100 m
9,4
9,4
10,5
10,5
15,8
15,8
11,5
11,5
13,2
13,2
13,2
18,9
18,9
18,9
27,8
35,6
16,2
16,2
16,2
23,2
23,2
23,2
33,9
44,3
82,3
114,7
187,4
250,5
333,1
474,9
600,7
749,5
19,9
19,9
19,9
28,5
28,5
28,5
41,9
41,9
56,2
56,2
100,4
136,6
310,0
32,6
43,8
Standard delivery
length m
100
500
100
500
100
500
100
500
50
100
500
50
100
500
500
500
50
100
500
50
100
500
500
500
500
500
500
500
500
250
250
250
50
100
500
50
100
500
50
500
50
500
500
500
250
500
500
Standard drum
size /Package
Coil
K6
Coil
K6
Coil
K6
Coil
K6
Coil
Coil
K6
Coil
Coil
K7
K7
K8
Coil
Coil
K6
Coil
Coil
K7
K8
K8
K11
K12
K16
K16
K18
K16
K18
K18
Coil
Coil
K7
Coil
Coil
K7
Coil
K8
Coil
K9
K12
K12
K12
K8
K9
Article number
952502070202
952502070205
952502080202
952502080205
952502100202
952502100205
952503070202
952503070205
952503080201
952503080202
952503080205
952503100201
952503100202
952503100205
952503110205
952503120205
952504080201
952504080202
952504080205
952504100201
952504100202
952504100205
952504110205
952504120205
952504130205
952504140205
952504150205
952504160205
952504170205
952504180204
952504190204
952504200204
952505080201
952505080202
952505080205
952505100201
952505100202
952505100205
952505110201
952505110205
952505120201
952505120205
952505130205
952505140205
952505160204
952507080205
952507100205
Draka Keila Cables | 71
Halogen-free and fire resistant cables
DRAKAFLEX-TARMO H07BN4-F
450/750 V LSZH
High quality rubber cable with an extended temperature range (-50°C – +90°C)
Application fields
Approval
Halogen-free oil and weather resistant cable for connection to moveable items and motors, outdoors, in
spaces with fire and explosion risks, in humid rooms
with corrosive contents and in hostile surroundings, e.g.
in industry and agriculture. Also for fixed installation
in temporary buildings and cabins. Suitable for working sites. Use up to 1000 V AC is permitted for fixed,
protected installation (in conduit or appliances) and also
for motor connections of hoisting motors and the like.
<HAR>, C
Standard
Total copper area x 15 N/mm2
HD 22.12 Part 6 (H07BN4-F) and
HD 22.12 Part 4 (H07BB-F) and
HD 22.4 (H07RN-F)
HD 308 S2:2002
SS-EN 50267-2-2 (corrosive gases)
SS-EN 50268-2 (smoke density)
IEC 60811-2-1 (ozone protection)
Design
Fire propagation class
F2 acc. to SS 424 14 75 and IEC 60332-1
and SS-EN 50265-2-1
Temperature range
In continuous operation max. conductor temp. . . . . 90˚C
The cable is flexible down to . . . . . . . . . . . . . . . . . . . –50˚C
72 | Draka Keila Cables
Material declaration
DRAKAFLEX-TARMO H07BN4-F
Bending radius
6 x overall diameter
Max tensile stress (N)
Conductor��������������flexible and annealed copper
acc. to IEC 60228 class 5
Insulation����������������EPDM-rubber class EI6
Core identification���2-core: blue, brown;
3-core: green/yellow, blue, brown;
4-core: green/yellow, brown, black,
grey;
5-core: green/yellow, blue, brown,
black, grey;
7-core: green/yellow, 6 cores black
number-marked 1–6;
Sheath��������������������weather and oil resistant rubber,
halogen-free; fulfills class EM2, EM6
and EM7
Marking e. g.����������DRAKAFLEX-TARMO H07BN4-F 5G
2,5 mm2 <HAR>
Product Catalogue
Halogen-free and fire resistant cables
DRAKAFLEX-TARMO H07BN4-F
450/750 V LSZH
High quality rubber cable with an extended temperature range (-50°C – +90°C)
No. of cores x cross section of conductor
mm2
2x1
2x2,5
3G1
3G1,5
3G1,5
3G2,5
3G4
3G6
4G1
4G1,5
4G2,5
4G6
4G10
4G16
5G1,5
5G1,5
5G2,5
5G2,5
5G4
5G6
5G10
5G16
7G1,5
7G2,5
Overall diameter (approx.)
mm
8,3
11,1
8,8
10,0
10,0
11,5
13,5
15,6
10
10,5
12,4
16,8
22,9
26
11,6
11,6
13,5
13,5
16,9
19,0
25,5
28,5
14,8
17,4
Weight (approx.)
kg/100 m
9,3
15,9
11,4
13,7
13,7
17,9
26,5
36,5
13,0
15,4
23,7
45,1
80,1
111,3
18,9
18,9
27,3
27,3
41,3
52,9
95,4
136,7
31,0
43,6
Standard delivery length
m
500
500
500
100
500
500
500
500
500
500
500
500
500
500
50
500
50
500
500
500
500
500
500
500
Std. drum size /package
Article number
K6
K6
K6
Coil
K6
K7
K7
K8
K6
K6
K7
K8
K11
K12
Coil
K7
Coil
K7
K8
K9
K12
K12
K8
K9
956502070205
956502100205
952503070205
952503080202
956503080205
956503100205
956503110205
956503120205
956504070205
956504080205
956504100205
956504120205
956504130205
956504140205
956505080201
956505080205
956505100201
956505100205
956505110205
956505120205
956505130205
956505140205
956507080205
956507100205
Electrical data
Type
Resistance at 200˚C
3G1,5
3G2,5
3G4
3G6
3G10
5G1,5
5G2,5
5G4
5G6
5G10
5G16
Ω/km
13,3
7,98
4,95
3,30
1,91
13,3
7,98
4,95
3,30
1,91
1,21
Ambient temperature
Conversion factor
300˚C
1
Reactance at 200˚C and 50 Hz Current carrying capacity with 900˚C at conductor and ambient temperature at 300˚C
Ω/km
mA
0,106
23
0,101
32
0,100
43
0,094
56
0,090
77
0,117
21
0,113
29
0,110
38
0,107
50
0,101
68
0,096
92
450˚C
0,96
400˚C
0,91
450˚C
0,87
Voltage drop between phases
V/A/km)
26,9
16,2
10,1
6,7
3,9
23,3
14,0
8,7
5,9
3,5
2,2
500˚C
0,82
Nominal values unless otherwise specified.
NOTE
Current ratings when installed in open air. National regulations must be followed.
When the cable is accessible during operation by personnel, it is recommended that steps are taken to ensure that the outside jacket temperature does not exceed 500˚C.
Following assumptions have been made:
• 2–3 core cable – single phase circuit;
• 4–5 core cable – three phase circuit.
Voltage drop has been determined for cos ø =0,8
Product Catalogue
Draka Keila Cables | 73
Halogen-free and fire resistant cables
HULT(FLEX) LSOH FB 90 0,6/1 kV
Fire resistant halogen-free power and control cable
Application
Construction
Halogen-free power and control cable for low voltage
applications 0,6/1 kV. Designed for vital installations
during fire and have circuit integrity during 30 and 60
minutes. Suitable in wet environments. Multicore cables
are specially applied for control engineering. Suited for
use in public buildings tunnels, railway stations, oil and
petrol chemical plants, etc where the danger to life
may be greatly increased in the event of a power failure
due to fire.
Conductor . . . . . . . . solid conductor up to 10 mm2;
10 mm2 and larger conductor sizes
stranded copper
Insulation . . . . . . . . . ceramifiable silicone rubber;
earthing core green/yellow polyethylene (PE)
Cores . . . . . . . . . . . . cores stranded together
Bedding . . . . . . . . . . halogen-free compound
Outer sheet . . . . . . . polyolefin, halogen-free compound
Properties and specifications
Colour coding cores
EN 50200 EN 50362, IEC 60331
and DIN 4102/12 Circuit Integrity During Fire
IEC 60332-3-22 (Cat A) Flame Retardant
IEC 60332-1 Self Extinguishing
IEC 60754 Halogen-free
IEC 61034 Low Smoke
1 core . . . . . . . . . . . .
2 cores . . . . . . . . . . .
3 cores . . . . . . . . . . .
4 cores . . . . . . . . . . .
Remarks
Other properties
General, for signalling cables 30 minutes circuit integrity required and for power cables is a minimum of 60
minutes circuit Integrity required.
Installation temp. . . min. –20˚C, max. +60˚C
Outer sheet colour . . red
Delivery . . . . . . . . . . on reels
black
blue brown
blue brown green/yellow
blue brown black green/yellow
blue brown black grey
5 cores . . . . . . . . . . . blue brown black grey green/yellow
Type
Nom. core diam.
Nom. outer diam.
Weight
Min. bending radius
Max. pulling force
Current Rating
Conductor 20˚C AC
Resistance 90˚C DC
mm
mm
kg/km
mm
N
A
Ω/km
Ω/km
2x1,5
3,4
11,6
175
95
400
26
12,1
15,4
3G1,5
3,4
12,1
190
100
435
26
12,1
15,4
4G1,5
3,4
13,9
230
115
575
23
12,1
15,4
5G1,5
3,4
14,3
260
115
610
23
12,1
15,4
7G1,5
3,4
14,9
265
120
665
17
12,1
15,4
2x2,5
3,4
12,4
210
100
460
36
12,1
15,4
3G2,5
3,8
13,0
230
105
505
36
7,41
9,45
4G2,5
3,8
15,3
340
125
700
32
7,41
9,45
5G2,5
3,8
18,0
410
145
970
25
7,41
9,45
7G2,5
3,8
16,1
350
130
775
23
7,41
9,45
4G6
4,9
15,6
420
125
730
54
3,08
3,93
5G6
4,9
17,0
510
140
865
54
3,08
3,93
4G10
7,1
20,0
775
160
1200
75
1,83
2,33
5G10
7,1
23,2
920
190
1610
75
1,83
2,33
4G16
8,3
22,0
1000
180
1450
100
1,15
1,47
5G16
8,3
26,6
1295
215
2120
100
1,15
1,47
Type
Nom. core diam.
Nom. outer diam.
Weight
Min. bending radius
Max. pulling force
Current Rating
Conductor 20˚C AC
Resistance 90˚C DC
mm
mm
kg/km
mm
N
A
Ω/km
Ω/km
4G25
9,6
26,0
1450
210
2025
127
0,727
0,927
5G25
9,6
30,2
1855
245
2735
127
0,727
0,927
4G35
10,8
30,0
1980
240
2700
158
0,524
0,669
5G35
10,8
33,7
2415
270
3405
158
0,524
0,669
4x50
12,1
34,6
2660
280
280
192
0,387
0,494
5G50
12,1
38,3
3240
310
310
192
0,387
0,494
4G70
13,1
40,0
3700
320
320
246
0.268
0.344
5G70
13,1
44,0
4440
355
355
246
0.268
0.344
5G95
15,8
49,4
5970
400
7320
298
0,193
0,248
4G120
17,2
50,0
6180
400
7500
346
0,153
0,198
5G120
17,2
54,4
7400
440
8875
346
0,153
0,198
4G150
19,2
55,0
7520
440
9075
399
0,124
0,161
4G185
21,5
61,0
9360
490
10000
456
0,0991
0,131
4G240
24,2
69,0
12120
555
10000
538
0,0754
0,102
1x300
26,9
33,0
3430
265
3265
703
0,0601
0,0831
1x400
30,2
37,0
4280
300
4105
823
0,0470
0,0685
Current rating: cables in free air according to IEC 60364-5-52
74 | Draka Keila Cables
Product Catalogue
Halogen-free and fire resistant cables
HULT(FLEX) LSOH FB30/60 0,6/1 kV
Fire resistant halogen-free power and control cable
Application
Construction
Halogen-free power and control cable for low voltage
applications 0,6/1 kV. Designed for vital installations
during fire and have circuit integrity during 30 and 60
minutes. Suitable in wet environments. Multicore cables
are especially applied for control engineering. Suited
for use in public buildings tunnels, railway stations, oil
and petrol chemical plants, etc where the danger to life
may be greatly increased in the event of a power failure
due to fire.
Conductor . . . . . . . . . solid conductor up to 10 mm2;
10 mm2 and larger conductor sizes
stranded copper
Insulation . . . . . . . . . . ceramifiable silicone rubber;
earthing core green/yellow polyethylene (PE)
Cores . . . . . . . . . . . . . cores stranded together
Bedding . . . . . . . . . . . halogen-free compound
Outer sheet . . . . . . . . polyolefin, halogen-free compound
Properties and specifications
Colour coding cores
EN 50200 EN 50362, IEC 60331
and DIN 4102/12 Circuit Integrity During Fire
IEC 60332-3-22 (Cat A) Flame Retardant
IEC 60332-1 Self Extinguishing
IEC 60754 Halogen-free
IEC 61034 Low Smoke
1 core . . . . . . . . . . . . .
2 cores . . . . . . . . . . . .
3 cores . . . . . . . . . . . .
4 cores . . . . . . . . . . . .
Remarks
Other properties
General, for signalling cables 30 minutes circuit integrity required and for power cables is a minimum of 60
minutes circuit integrity required.
Installation temp. . . . min. –20˚C, max. +60˚C
Outer sheet colour . . red
Delivery . . . . . . . . . . . on reels
black
blue brown
blue brown green/yellow
blue brown black green/yellow
blue brown black grey
5 cores . . . . . . . . . . . . blue brown black grey green/yellow
Type
Nom. core diam.
Nom. outer diam.
Weight
Min. bending radius
Max. pulling force
Current Rating
Conductor 20˚C AC
Resistance 90˚C DC
mm
mm
kg/km
mm
N
A
Ω/km
Ω/km
2x1,5
3,4
11,6
175
95
400
26
12,1
15,4
3G1,5
3,4
12,1
190
100
435
26
12,1
15,4
4G1,5
3,4
13,9
230
115
575
23
12,1
15,4
5G1,5
3,4
14,3
260
115
610
23
12,1
15,4
7G1,5
3,4
14,9
265
120
665
17
12,1
15,4
2x2,5
3,4
12,4
210
100
460
36
12,1
15,4
3G2,5
3,8
13,0
230
105
505
36
7,41
9,45
4G2,5
3,8
15,3
340
125
700
32
7,41
9,45
5G2,5
3,8
18,0
410
145
970
25
7,41
9,45
7G2,5
3,8
16,1
350
130
775
23
7,41
9,45
24G2,5
3,8
31,0
1280
250
2880
13,5
7,41
9,45
5G4
4,4
16,6
390
125
730
42
4,61
5,88
4G6
4,9
15,6
420
125
730
54
3,08
3,93
5G6
4,9
17,0
510
140
865
54
3,08
3,93
5G10
7,1
23,2
920
190
1610
75
1,83
2,33
Type
Nom. core diam.
Nom. outer diam.
Weight
Min. bending radius
Max. pulling force
Current Rating
Conductor 20˚C AC
Resistance 90˚C DC
mm
mm
kg/km
mm
N
A
Ω/km
Ω/km
5G16
8,3
26,6
1295
215
2120
100
1,15
1,47
5G25
9,6
30,2
1855
245
2735
127
0,727
0,927
5G35
10,8
33,7
2415
270
3405
158
0,524
0,669
4G50
12,1
34,6
2670
280
280
192
0,387
0,494
5G50
12,1
38,3
3240
310
310
192
0,387
0,494
5G70
13,1
44,0
4440
355
355
246
0.268
0.344
4G95
15,8
44,6
4895
360
5965
298
0,193
0,248
5G95
15,8
49,4
5970
400
7320
298
0,193
0,248
4G120
17,2
50,0
6180
400
7500
346
0,153
0,198
5G120
17,2
54,4
7400
440
8875
346
0,153
0,198
4G150
19,2
55,0
7520
440
9075
399
0,124
0,161
4G185
21,5
61,0
9360
490
10000
456
0,0991
0,131
4G240
24,2
69,0
12120
555
10000
538
0,0754
0,102
1x300
26,9
33,0
3430
265
3265
703
0,0601
0,0831
1x400
30,2
37,0
4280
300
4105
823
0,0470
0,0685
Current rating: cables in free air according to IEC 60364-5-52
Product Catalogue
Draka Keila Cables | 75
Halogen-free and fire resistant cables
Signal cable type 2300 FB 30 (mbzh)
Halogen-free overall screened multipair signal cable
with circuit integrity FE90/E30
Application
Core colours
• Special developed for those parts of the circuit installations where 30 minutes circuit integrity is required.
• Suitable for applications mentioned in NPR 2576,
especially where the demands of fire safety are high.
• Halogen-free signalling cable for fixed installation.
• Suitable for areas with many electromagnetic interference (EMI) signals.
• Suitable for use in zone 1 and 2 (explosion safety).
Standard colours . . in accordance with NEN 1597
Properties regarding fire performance
Minimum installation temperature . . . . . . . . . . . . . . –20˚C
Operating temperature . . . . . . . . min. –40˚C, max. +70˚C
• Circuit integrity in accordance with NEN-EN 50200, in
combination with all approved cable tray systems and
mounting methods, in accordance with DIN 4102 part 12.
• Fire Resistant, in accordance with IEC 60331.
• Halogen-free, in accordance with NEN-EN 50267
(IEC 60754).
• Low smoke, in accordance with NEN-EN-IEC 61034.
• Flame retardant, in accordance with
NEN-EN-IEC 60332-3-24 Cat C.
• Self-extinguishing, in accordance with
NEN-EN-IEC 60332-1.
General properties
• Good signal transmission at frequencies up to 100 kHz.
• The construction of the cable largely prevents cross
talk between the pairs.
• The overall shield offers good protection against electromagnetic interference (EMI).
Remarks
• Not suitable for power installations.
• 1,5 and 2,5 mm2 types suitable for 100 V audio systems.
• When larger conductor size is required and screening
unnecessary, type HULT FB 30 can be used.
Construction
Conductor . . . . . . . solid plain copper
Insulation . . . . . . . . ceramifiable silicon rubber (XLSr)
Cores . . . . . . . . . . . 2 cores twisted to a pair
4 cores twisted to a quad
Assembly . . . . . . . . pairs or quad cabled and wrapped
with glass tape
Overall screen . . . . metallized polyester foil with underneath a drain wire of tinned copper
Outer sheath . . . . . halogen-free flame retardant thermoplastic (LSOH)
Standards/References
KEMA 163, NEN 2535, NEN 2575, NEN-EN 50200,
NEN-EN-IEC 60332-1, NEN-EN-IEC 60332-3,
NEN-EN-IEC 61034, NEN-EN 50267, IEC 60754
Additional information:
Construction data
Diameter conductor . . . . . . . . . . . . . . . . . . . . . . . . . 0.8 mm
Conductor category . . . . . . . . . . . . . . . . . . . . class 1 = solid
Core insulation . . . . . . . . . . . . . . . . . . . . . . rubber (silicone)
Core identification . . . . . . . . . . . . . . . . . . . . . . . . . . . .colour
Screen over stranding element . . . . . . . . . . . . . . . . . . none
Screen over stranding . . . . . . . . . . . . . . . . . . . . . . . . . . . .foil
Longitudinal water blocking . . . . . . . . . . . . . . . . . . . . . . . no
Radial water blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . no
Protective sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no
Armouring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no
Material outer sheath . . . . . . . .copolymer, thermoplastic
Colour outer sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red
Halogen-free . . . . . . . . . . . . . . . . . .yes (acc. EN 50267-2-2)
Flame retardant . . . . . . . . . . . . . . . . . . . .acc. EN 60332-1-2
Low smoke . . . . . . . . . . . . . . . . . . . . . yes (acc. EN61034-2)
Circuit integrity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 60
Operating temperature, flexible . . . . . . . . . . . . . -20/70˚C
Operating temperature, fix . . . . . . . . . . . . . . . . . . -40/90˚C
Outdoor use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes
Conductor material . . . . . . . . . . . . . . . . . . . . . . . . . Cu, bare
Fire-resistant layer (core) . . . . . . . . . . . . . . . . . . . . . . . . yes
Fire-resistant layer (lay-up) . . . . . . . . . . . . . . . . . . . . . . yes
Armouring/reinforcement . . . . . . . . . . . . . . . . . . . . . . none
Properties
Oil resistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . good
Electrical standards
Standard KEMA K102
Others
Sheath colour . . . . . . . . red
Approval. . . . . . . . . . . . . KEMA-KEUR
Packaging . . . . . . . . . . . coils, drums
Electrical properties
Voltage rating . . . . . . . . 300 V
Test voltage . . . . . . . . . . 1 kV
Insulation resistance . . > 100 MΩ/km
76 | Draka Keila Cables
Product Catalogue
Halogen-free and fire resistant cables
Signal cable type 2300 FB 30 (mbzh)
Halogen-free overall screened multipair signal cable
with circuit integrity FE90/E30
Product number No. of cores and
conductor
cross section
n x mm/mm2
127273
1 x 2 x 0,8
127274
1 x 4 x 0,8
128130
1 x 2 x 1,5
128126
1 x 2 x 2,5
127275
2 x 2 x 0,8
128127
2 x 2 x 1,5
128128
2 x 2 x 2,5
127276
4 x 2 x 0,8
128122
8 x 2 x 0,8
128123
12 x 2 x 0,8
128125
16 x 2 x 0,8
128129
20 x 2 x 0,8
Type
2301
2302Q
2301.150
2301.250
2302
2302.150
2302.250
2304
2308
2312
2316
2320
Nominal overall Minimum
diameter
bending radius
Maximum
Approx. weight
tensile strength
mm
6,6
7,5
8,9
10,1
9,6
14,1
14,9
10,5
13,0
14,4
15,8
17,7
N
15
30
45
75
30
90
150
60
120
180
240
300
mm
40
45
55
65
60
85
90
65
80
90
95
110
kg/km
55
80
100
125
85
210
260
130
200
265
330
410
Conductor
resistance at
20°C, DC
Ω/km
37,5
37,5000
12,1000
7,4100
37,5
12,1000
7,4100
37,5
37,5
37,5
37,5
37,5
Mutual capacitance
µF/km
120
120
150
150
120
150
150
120
120
120
120
120
Type 2302Q FB30: 2 pairs constructed as a quad, the opposite cores form a pair.
Product Catalogue
Draka Keila Cables | 77
Halogen-free and fire resistant cables
Signal cable type 2300 FB 90 (mbzh)
Halogen-free overall screened multipair signal cable
with circuit integrity FE90/E90
Application
Core colours
• Special developed for those parts of the circuit installations where 90 minutes circuit integrity is required.
• Suitable for applications mentioned in NPR 2576,
especially where the demands of fire safety are high.
• Halogen-free signalling cable for fixed installation.
• Suitable for areas with many electromagnetic interference (EMI) signals.
• Suitable for use in zone 1 and 2 (explosion safety).
Standard colours . . .in accordance with NEN 1597.
Properties regarding fire performance
Minimum installation temperature . . . . . . . . . . . . . . –20˚C
Operating temperature . . . . . . . .min. –40˚C, max. +90˚C
• Circuit integrity in accordance with NEN-EN 50200, in
combination with all approved cable tray systems and
mounting methods, in accordance with DIN 4102 part 12.
• Fire Resistant, in accordance with IEC 60331.
• Halogen-free, in accordance with NEN-EN 50267
(IEC 60754).
• Low smoke, in accordance with NEN-EN-IEC 61034.
• Flame retardant, in accordance with
NEN-EN-IEC 60332-3-24 Cat C.
• Self-extinguishing, in accordance with
NEN-EN-IEC 60332-1.
General properties
• Good signal transmission at frequencies up to 100 kHz.
• The construction of the cable largely prevents cross
talk between the pairs.
• The overall shield offers good protection.
Remarks
• Not suitable for power installations.
• 1,5 and 2,5 mm2 types suitable for 100 V audio systems.
• When larger conductor size is required and screening
unnecessary, type HULT FB 30/60 can be used.
Construction
Conductor . . . . . . . . . . . solid plain copper
Insulation . . . . . . . . . . . . ceramifiable silicon rubber (XLSr)
Cores . . . . . . . . . . . . . . . 2 cores twisted to a pair
4 cores twisted to a quad
Assembly . . . . . . . . . . . . pairs or quad cabled and
wrapped with glass tape
Overall screen . . . . . . . . metallized polyester foil with
a drain wire of tinned copper
underneath
Outer sheath . . . . . . . . . halogen-free flame retardant
thermoplastic (LSOH)
Standards/References
KEMA 163, NEN 2535, NEN 2575, NEN-EN 50200,
NEN-EN-IEC 60332-1, NEN-EN-IEC 60332-3,
NEN-EN-IEC 61034, NEN-EN 50267, IEC 60754
Additional information:
Construction data
Diameter conductor . . . . . . . . . . . . . . . . . . . . . . . . . 0,8 mm
Conductor category . . . . . . . . . . . . . . . . . . . . class 1 = solid
Core insulation . . . . . . . . . . . . . . . . . . . . . . rubber (silicone)
Core identification . . . . . . . . . . . . . . . . . . . . . . . . . . . .colour
Screen over stranding element . . . . . . . . . . . . . . . . . . none
Screen over stranding . . . . . . . . . . . . . . . . . . . . . . . . . . . .foil
Longitudinal water blocking . . . . . . . . . . . . . . . . . . . . . . . no
Radial water blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . no
Protective sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no
Armouring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . no
Material outer sheath . . . . . . . .copolymer, thermoplastic
Colour outer sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red
Halogen-free (acc. EN 50267-2-2) . . . . . . . . . . . . . . . . . yes
Flame retardant . . . . . . . . . . . . . . . . . . . .acc. EN 60332-1-2
Low smoke (acc. EN61034-2) . . . . . . . . . . . . . . . . . . . . . yes
Circuit integrity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 90
Operating temperature, flexible . . . . . . . . . . . . . –20/70˚C
Operating temperature, fix . . . . . . . . . . . . . . . . .–40/90˚C
Outdoor use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes
Conductor material . . . . . . . . . . . . . . . . . . . . . . . . . Cu, bare
Fire-resistant layer (core) . . . . . . . . . . . . . . . . . . . . . . . yes
Fire-resistant layer (lay-up) . . . . . . . . . . . . . . . . . . . . . . yes
Armouring/reinforcement . . . . . . . . . . . . . . . . . . . . . . none
Properties
Oil resistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . good
Electrical standards
Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KEMA K102
Others
Sheath colour . . . . . . . . red
Approval. . . . . . . . . . . . . KEMA-KEUR
Packaging . . . . . . . . . . . coils, drums
Electrical properties
Voltage rating . . . . . . . . 300 V
Test voltage . . . . . . . . . . 1 kV
Insulation resistance . . > 100 MΩ/km
78 | Draka Keila Cables
Product Catalogue
Halogen-free and fire resistant cables
Signal cable type 2300 FB 90 (mbzh)
Halogen-free overall screened multipair signal cable mbzh
with circuit integrity FE90/E90
Product number No. of cores
and conductor
cross section
n x mm/mm2
Type
Nominal overall Minimum
diameter
bending radius
Maximum
Approx. weight
tensile strength
mm
mm
N
kg/km
Conductor
resistance at
20°C, DC
Ω/km
122171
122172
1x2x0,8
1x4x0,8
2301
2302Q
6,6
7,5
55
60
15
30
55
80
37,5
37,5000
122444
129171
1x2x1,5
1x2x2,5
2301.150
2301.250
8,9
10,1
75
85
45
75
100
125
7,4100
7,4100
122450
129172
2x2x0,8
2x2x1,5
2302
2302.150
9,6
12,2
80
100
30
90
85
210
37,5
12,1000
129173
122173
2x2x2,5
4x2x0,8
2302.250
2304
14,9
10,5
120
85
150
60
260
130
7,4100
37,5
122174
122175
8x2x0,8
12x2x0,8
2308
2312
13,0
14,4
105
120
120
180
200
265
37,5
37,5
122176
122177
16x2x0,8
20x2x0,8
2316
2320
15,8
17,7
130
145
240
300
330
410
37,5
37,5
Mutual
capacitance
µF/km
120
120
150
150
120
150
150
120
120
120
120
120
Type 2302Q FB90: 2 pairs constructed as a quad, the opposite cores form a pair.
Product Catalogue
Draka Keila Cables | 79
Halogen-free and fire resistant cables
Draka SF/UTP Cat."5" FB 90 (mbzh)
SF/UTP FB 90 cat "5" rd# 4x2x22 AWG
DIN: J-02YSCH PiMF
Additional information
Application
Minimum installation temperature . . . . . . . . . . . . . . . . 0˚C
Operating temperature . . . . . . . . min. -20˚C, max. +60˚C
Bending radius: fixed installation . . . . . . . . . . . . . . . . . . 4D
Sheath colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red
Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .drums
· Specially developed for those parts of circuit installations where 90 minutes circuit integrity is required
· Primary (Campus), Secondary (Riser) and Tertiary
(Horizontal)
· IEEE 802.3 networks: 10Base-T, 100Base-T and
1000Base-T
· IEEE 802.5 16 MB networks: ISDN, TPDDI and ATM
· Industrial Ethernet application
Properties regarding fire performance
· Circuit integrity in accordance with NEN-EN 50200, BS
5839-1:2002 Clause 26.2e Enhanced, BS 8434-2:2003
· Fire resistant in acc. with IEC 60331-23 and BS 6387-C
· Halogen-free in acc. with NEN-EN 50267 (IEC 60754)
· Low smoke in accordance with NEN-EN-IEC 61034
· Flame retardant in accordance with NEN-EN 50266-2-3
and UL 1581 VW1
· Self-extinguishing in acc. with NEN-EN-IEC 60332-1
General properties
· In areas effected by electromagnetic interference
signals (EMC)
· Construction of the cable is such that is approaches
the properties of a Cat 5 cable as much as possible
Remarks
· There is also a single and a double pair construction
with a conductor diameter of 0,63 mm
Construction
Conductor . . . . . . . solid plain copper
Insulation . . . . . . . . silicon rubber (SiR) and polyethylene
(PE)
Cores . . . . . . . . . . . 2 cores twisted to a pair, wrapped
with glass tape
Overall screen . . . . metallized polyester foil
Braiding . . . . . . . . . tinned copper wires, with a tinned
copper drain wire underneath
Outer sheath . . . . . halogen-free flame retardant thermoplastic (LSOH)
Core colours
Standard colours. . . white/blue and blue, white/orange
and orange, white/green and green,
white/brown and brown (in accordance with ISO/IEC 11801)
Standards/References
EIA/TIA 568A, ISO/IEC 11801, NEN-IEC 61156-6,
NEN-EN 50173, NEN-EN 50288-4-2
80 | Draka Keila Cables
Electrical data
Insulation resistance
LDC loop resistance
Resistance unbalance
Characteristic impedance
Return loss
Capacitance unbalance (pair to ground)
Velocity ratio
Construction data
Conductor material
Diameter conductor
AWG-size
Conductor category
Number of cores
Stranding element
Core insulation
Core identification
Screen over stranding element
Screen over stranding
Material outer sheath
Colour outer sheath
Halogen-free (acc. EN 50267-2-2)
Flame retardant
Low smoke (acc. EN61034-2)
Outer diameter
Operating temperature, flexible
Operating temperature, fix
Category
Armouring/reinforcement
Protective sheath
Weight
Copper content
Elements
Number of stranding elements
Properties
Circuit integrity
Max. tensile force
Bending radius
Electrical
Characteristic impedance
Applications
Patch
Product packing
Product number
Description
≥ 5000 MΩ/km
≤ 192 Ω/km
≤2%
100 ± 15 Ω (1 - 100 MHz)
in acc. with ISO/IEC 11801
≤ 1600 pF/km
± 57%
Cu, bare
0,64 mm
22
Class 1 = solid
8
pairs
other
colour
none
other
copolymer, thermoplastic
red
yes
acc. EN 50266-2-4
yes
approx. 10.5 mm
-20/60˚C
-20/60˚C
5
none
no
125 kg
41 kg
x2x
4
E 90
100 N
85 mm
100 Ω
no
128690NN
length of 1 m
Product Catalogue
Halogen-free and fire resistant cables
BI(c) 250V
Fire resistant halogen-free control cable
Application
Construction
As alarm, control, and signal cables in places where
during a fire the cable must sustain its functionality for
a certain amount of time in order to protect people or
machinery. For indoor and outdoor use.
CENELEC HD 627-7B, IEC 60502-1, IEC 60332-3C, IEC
60331 and EN50200, IEC 60754-1 and 2, IEC 61034
Conductor . . . . . . . annealed, tinned copper, multistranded
Insulation . . . . . . . . Mica-tape and EPDM-rubber, colour
and numerical markings
Shielding . . . . . . . . aluminium/polyester band and
ground wire as a unified shielding
Outer sheath . . . . . orange halogen-free polymer, production date and metric markings
Certificates
Colour coding cores
CE, RoHS
Conductor colour
and pair . . . . . . . . . BLA/BLU and number tape on pair
Four core . . . . . . . . BLA/BLU and BLA/BR
Standards
Properties
Rated voltage Um . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250V
Max allowed temperature for the cable:
- continuous use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70˚C
- in case of short circuit (max 5 sec). . . . . . . . . . . . . 160˚C
Min recommended usage temperature . . . . . . . . . . –15˚C
Min recommended bending radius
- when installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10D
- for permanent installation as a one-time bend . . . . . . . 5D
Max allowed tension during installation . . . .Ax50 N/mm2
Product Catalogue
mm2
No. of cable pairs/cables and area of cross section
Art No.
Approx. diameter
Approx. weight
Standard length
mm
kg/km
m
Standard package
Properties
Capacitance of the cable pair
Inductance
Impedance / 1 kHz
Conductor resistivity, max (20 ˚C)
Loop resistivity, max (20 ˚C)
µF/km
mH/km
Ω/km
Ω/km
Ω/km
2 x 0,75
460961
6,5
70
500
S4
1 x 4 x 0,75
460922
8,4
115
500
S4
2 x 2 x 0,75
461110
10,3
140
500
K7
4 x 2 x 0,75
461120
11,9
210
500
K7
80
0,75
330
24,8
49,6
Draka Keila Cables | 81
Halogen-free and fire resistant cables
BFSI-EMC 1 kV
Halogen-free and fire-resistant EMC compatible power cable
Application
Approvals
Installations with rated voltage up to 1 kV, in case of
requirement for a cable to function during a fire. This
is a cable for indoor and outdoor use. Improved EMC
screen according to EMC directive. Halogen-free cable
is recommended when it is important to avoid heavy
smoke and corrosive gases in case of a fire. National
regulations for electrical installations must be followed.
NEMKO, CE-marking, acc. to LVD.
Max conductor temp . . . . . . . . . . . . . . . . . . . . . . . . . . 9O˚C
Rated voltage U0/U . . . . . . . . . . . . . . . . . . . . . . . . . 0,6/1 kV
CENELEC designation . . . . . . . . . . . . . . . . . . . . . N1ZC7Z1-R
Standards applied
CENELEC HD 604-5D Construction
IEC 60502-1 Insulation
IEC 60331 Fire Resistant
IEC 60332-3C Flame Retardancy
IEC 60754-1 and 2 Halogen-free
IEC 61034 Low Smoke
No. of cores and conductor area
mm2
2 x 1,5/1,5
2 x 2,5/2,5
2 x 6/6
3 x 1,5/1,5
3 x 2,5/2,5
3 x 4/4
3 x 6/6
3 x 10/10
3 x 16/16
3 x 25/16
3 x 35/16
3 x 50/25
4 x 1,5/1,5
4 x 2,5/2,5
4 x 4/4
4 x 6/6
4 x 10/10
4 x 16/16
4 x 25/16
4 x 35/16
4 x 50/25
4 x 70/35
4 x 95/50
4 x 150/70
Construction
Conductor . . . . . . . . . . .
Insulation . . . . . . . . . . . .
Bedding . . . . . . . . . . . . .
Concentric conductor . .
stranded copper
Mica-tape and extruded XLPE
halogen-free
(PE/PEN conductor) copperfoil
with overlap and concentric
screen of copper wires.
Outer sheath . . . . . . . . . halogen-free polymer
Colour . . . . . . . . . . . . . . . black
Mode of packing . . . . . . drum
Marking
Printed on outer sheath, designation and dimension.
Meter marking and year of production.
Conductor type 1) El. No.
Art. No.
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FV
FV
FR
FR
FR
FR
FR
FR
FR
FV
FV
FV
FV
FV
422605
422615
422640
422610
422620
422630
422645
422655
422660
422670
422675
422680
422612
422625
422635
422650
422657
422665
422673
422677
422685
422690
422693
422695
1046120
1046121
1046123
1046140
1046141
1046142
1046143
1046144
1046145
1046146
1046147
1046148
1046160
1046161
1046162
1046163
1046164
1046165
1046166
1046167
1046168
1046169
1046170
1046172
Outer diameter appr.
mm
12
13
15
12
13
15
16
19
22
25
24
27
13
14
16
17
21
24
27
27
30
36
40
48
Approx. weight
kg/km
150
190
300
180
220
290
380
570
860
1150
1380
1840
200
260
350
460
690
1050
1430
1750
2330
3280
4500
6700
1) FR =Stranded round.
FV=Stranded sector shaped.
Mode of packing and length can be changed.
82 | Draka Keila Cables
Product Catalogue
Halogen-free and fire resistant cables
HULT(FLEX) LSOH 0,6/1 kV
Halogen-free Power and Control Cable
Application
Colour coding cores
Halogen-free Power and Control cable for Low Voltage
applications 0,6/1 kV. Suitable in wet environments. Multicore cables are especially applied for control engineering. Suited for use in Public buildings tunnels, Railway
Stations, Oil and Petrol.
1 core . . . . . . . . . . . black
2 cores . . . . . . . . . . blue brown
3 cores . . . . . . . . . . blue brown green/yellow
4 cores . . . . . . . . . . blue brown black green/yellow
blue brown black grey
5 cores . . . . . . . . . . blue brown black grey green/yellow
Properties and Specifications
IEC 60332-3-22 (Cat A) Flame Retardant
IEC 60332-1 Self Extinguishing
IEC 60754 Halogen-free
IEC 61034 Low Smoke
Other properties
Min. installation temperature . . . . . . . –20˚C, max. +60˚C
Max. conductor temperature . . . . . . . . . . . . . . . . . . . .90˚C
Outer sheet colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . on reels
Construction
Conductor . . . . . . . Solid conductor up to 10 mm2
10 mm2 and larger conductor sizes
stranded copper
Insulation . . . . . . . . polyethylene (PE)
Cores . . . . . . . . . . . cores cabled together
Bedding . . . . . . . . . halogen-free compound
Outer sheet . . . . . . polyolefin, halogen-free compound
Type
2x1,5
2x2,5
3G1,5
3G2,5
4G1,5
4G2,5
4G4
4G6
4G10
4G16
4G25
4G35
4G50
4G70
4G95
4G150
5G1,5
Nom.
outer
diam.
Weight Min.
Current Conduc- Resist- Working Working
bending rating
tor 20°C ance
induct- capaci90°C DC ance
radius
AC
tance
mm
9,5
10,3
9,9
10,7
10,7
11,5
12,6
13,8
17,1
19,7
23,8
26,7
31,6
36,6
41,8
51,3
11,5
kg/km
130
165
150
190
175
220
295
390
620
895
1360
1770
2445
3410
4550
7180
200
Product Catalogue
mm
50
55
50
55
55
60
80
85
105
120
170
135
160
185
210
260
60
A
26
36
26
36
23
32
42
54
75
100
127
158
192
246
298
399
23
Ω/km
12,1
7,41
12,1
7,41
12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,124
12,1
Ω/km
15,4
9,45
15,4
9,45
15,4
9,45
5,88
3,93
2,33
1,47
0,927
0,669
0,494
0,344
0,248
0,161
15,4
mH/km
0,33
0,31
0,33
0,31
0,37
0,35
0,33
0,32
0,29
0,28
0,28
0,26
0,25
0,25
0,25
0,24
0,41
µF/km
55
63
56
63
123
142
150
159
185
212
227
240
242
245
255
270
128
Type
5G2,5
5G4
5G6
5G10
5G16
5G25
5G35
5G50
5G70
5G95
5G120
5G150
7G1,5
7G2,5
12G1,5
12G2,5
24G1,5
Nom.
outer
diam.
Weight Min.
Current Conduc- Resist- Working Working
bending rating
tor 20°C ance
induct- capaci90°C DC ance
radius
AC
tance
mm
12,5
13,7
15
18,7
21,5
26,2
29,5
34,9
40,5
46,5
51,4
57,6
12
13,1
15,2
16,8
20,2
kg/km
260
350
460
745
1080
1655
2160
2990
4180
5710
7130
8900
215
285
330
440
585
mm
75
85
90
115
155
185
150
175
205
235
260
290
60
80
95
105
145
A
32
42
54
75
100
127
158
192
246
298
346
399
17
23
13
18
9,5
Ω/km
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
12,1
7,41
12,1
7,41
12,1
Ω/km
9,45
5,88
3,93
2,33
1,47
0,927
0,669
0,494
0,344
0,248
0,198
0,161
15,4
9,45
15,4
9,45
15,4
mH/km
0,38
0,36
0,34
0,32
0,31
0,3
0,3
0,27
0,23
0,22
0,21
0,2
-
µF/km
147
155
164
190
217
232
243
245
247
268
280
285
≤ 150
≤ 150
≤ 150
≤ 150
≤ 150
Draka Keila Cables | 83
Halogen-free and fire resistant cables
EQQ-Light 300/500 V
Halogen-free installation cable
Application fields
Approval
Halogen-free, no emittance of corrosive gases, low
smoke density in case of fire. Fixed installation, in pipes,
ducts, in or under plaster, also suspended in catenary
system. Indoors and outdoors, however not in ground
or water. UV protected (1) for outdoor use in the Nordic
countries.
SEMKO, S-marked, C
Alternative Designation
EKK-Light
SE-S05Z1Z1-U
Bending radius
Standard
8D (4D in final installation, bent only once)
SS 424 02 19-5 and EN 50265-2-1 (corrosive gases)
EN 50268-2 (smoke density)
Design
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN
50265-2-1
Temperature range
In continuous operation max. conductor temp. . . . . 70˚C
Lowest cable temperature under installation. . . . . . –15˚C
and below 0˚C special precaution shall be taken
Number of cores x
Overall diameter
cross section of con- (approx.)
ductor
mm2
mm
Without earth conductor
2 x 1,5
8,6
With earth conductor
3G1,5
8,6
3G1,5
8,6
3G1,5
8,6
3G2,5
10,7
3G2,5
10,7
3G2,5
10,7
4G1,5
10,1
4G1,5
10,1
4G1,5
10,1
5G1,5
10,2
5G1,5
10,2
5G1,5
10,2
5G2,5
12,8
5G2,5
12,8
5G2,5
12,8
Material declaration
EQQ-Light
PVC alternative
Conductor��������������solid and annealed copper acc. to IEC
60228 class 1
Insulation����������������halogen-free compound
Core identification��2-core: blue, brown
3-core: green/yellow, blue, brown
4-core: green/yellow, blue, brown, black
5-core: green/yellow, blue, brown,
black, grey
Filler������������������������halogen-free compound
Sheath��������������������halogen-free compound, white,
meter marked
Marking������������������������e.g. DRAKA EQQ-LIGHT 3G1,5 300/500
V LSZH S
Weight (approx.)
Standard delivery
length
Standard drum size Article number
/Package
kg/100 m
m
10,0
500
K6
0445065
10,9
10,9
10,9
16,9
16,9
16,9
14,2
14,2
14,2
15,3
15,3
15,3
23,9
23,9
23,9
50
250
500
50
150
500
50
200
500
50
150
500
50
150
500
Coil
K4,5
K6
Coil
K4,5
K6
Coil
K4,5
K6
Coil
K4,5
K6
Coil
K4,5
K7
0445001
0445003
0445005
0445011
0445013
0445015
0445021
0445023
0445025
0445041
0445043
0445045
0445051
0445053
0445055
1) UV – ultraviolet radiation
Nominal values unless otherwise specified.
84 | Draka Keila Cables
Product Catalogue
Halogen-free and fire resistant cables
EQLQ 450/750 V
Halogen-free installation cable
Application fields
Material declaration
Halogen-free, no emittance of corrosive gases, low
smoke density in case of fire. Fixed installation, indoors
and outdoors, in pipes, ducts, in or under plaster, also
suspended in catenary system. In ground, only if the
cable is protected against mechanical damage.
EQLQ
Alternative designation
Bending radius
Design
Standard
Conductor . . . . . . . . . . . . solid and annealed copper
acc. to IEC 60228 class 1
Insulation . . . . . . . . . . . . . halogen-free polymer
SS 424 02 19-4 In Applicable Parts
HD 604 Halogen-free Materials
EN 50267-2-2 Corrosive Gases
EN 50268-2 Low Smoke Density
Core identification
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1 and SS-EN
50265-2-1
Temperature range
In continuous operation max. conductor temp . . . . . 70˚C
Lowest cable temperature under installation . . . . . –15˚C
and below 0˚C special precaution shall be taken
Approval
SEMKO, S-marked, CE
Product Catalogue
EKLK
12D (6D in final installation, bent only once)
N07Z1A5EZ1-U
Number of cores x cross
section of conductor
n x mm2
3G1,5
3G1,5
3G1,5
3G2,5
3G2,5
3G2,5
4G1,5
4G1,5
4G1,5
4G2,5
4G2,5
5G1,5
5G1,5
5G1,5
5G2,5
5G2,5
5G2,5
PVC alternative
Overall diameter
(approx.)
mm
9,9
9,9
9,9
11,8
11,8
11,8
11,2
11,2
11,2
13,3
13,3
12
12
12
13,6
13,6
13,6
Weight (approx.)
kg/100 m
13,2
13,2
13,2
18,7
18,7
18,7
17,2
17,2
17,2
26,1
26,1
17,8
17,8
17,8
26,8
26,8
26,8
3-core . . . . . . . . . . . . . . . . green/yellow, blue, brown
4-core . . . . . . . . . . . . . . . . green/yellow, blue, brown, black
5-core . . . . . . . . . . . . . . . . green/yellow, blue, brown,
black, grey
Filler . . . . . . . . . . . . . . . . . halogen-free polymer
Concentric conductor . . . aluminium with bonded PE
in contact with drain wire of
tinned copper
Sheath . . . . . . . . . . . . . . . halogen-free polymer, white,
meter marked
Marking . . . . . . . . . . . . . . e.g. EQLQ 3G1,5 450/750 V F3
LSZH DRAKA S.
Standard delivery
length
m
50
250
500
50
150
500
50
200
500
50
500
50
150
500
50
150
500
Standard drum
size/package
Article number
Coil
K4,5
K6
Coil
K4,5
K7
Coil
K4,5
K6
Coil
K7
Coil
K4,5
K7
Coil
K4,5
K7
460001
460003
460005
460011
460013
460015
460021
460023
460025
460031
460035
460041
460043
460045
460051
460053
460055
Draka Keila Cables | 85
Halogen-free and fire resistant cables
FQLQ 450/750 V
Halogen-free installation cable
Application fields
Material declaration
Halogen-free, no emittance of corrosive gases, low
smoke density in case of fire. Fixed installation, indoors
and outdoors, in pipes, ducts, in or under plaster, also
suspended in catenary system. In ground, only if the
cable is protected against mechanical damage.
EQLQ, FQLQ
Alternative designation
N07Z1A5EZ1-R
Standard
SS 424 02 19-4 In Applicable Parts
HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1 & EN 50265-2-1
Temperature range
In continuous operation max. conductor temp. . . . . 70˚C
Lowest cable temperature under installation. . . . . . –15˚C
and below 0˚C special precaution shall be taken.
Approval
Bending radius
12D (6D in final installation, bent only once)
Design
Conductor������������������������� stranded and annealed copper
acc. to IEC 60228 class 2
Insulation��������������������������� halogen-free compound
Core identification
3-core��������������������������������� green/yellow, blue, brown
4-core��������������������������������� green/yellow, blue, brown, black
5-core��������������������������������� green/yellow, blue, brown, black,
grey
7-core��������������������������������� green/yellow, 6 cores black
number-marked 1-6
Filler����������������������������������� halogen-free compound
Concentric conductor����� aluminium with bonded PE
in contact with drain wire of
tinned copper
Sheath������������������������������� halogen-free compound, white,
meter marked
Marking����������������������������� e.g. FQLQ 5G2,5 450/750 V
LSZH DRAKA SE F3 S.
SEMKO, S-marked CE
Number of cores x cross
section of conductor
n x mm2
3G1,5
3G2,5
4G1,5
5G1,5
5G2,5
7G1,5
7G2,5
86 | Draka Keila Cables
Overall diameter
(approx.)
mm
10,3
12,4
11,6
12,4
14,1
13
15,4
Weight (approx.)
kg/100 m
15,7
20,7
18
20,6
28,5
24,5
34,9
Standard delivery
length
m
500
500
500
500
500
500
500
Standard drum
size/Package
Article number
K6
K7
K7
K7
K7
K7
K8
5,17503E+11
5,17503E+11
5,17504E+11
5,17505E+11
5,17505E+11
5,17507E+11
5,17507E+11
Product Catalogue
Halogen-free and fire resistant cables
AXQJ 0,6/1 kV
Halogen-free power cable
Application fields
Material declaration
Halogen-free and fire classified cable. No emittance of
corrosive gases, low smoke density in case of fire. Open,
fixed installation, indoors and outdoors, in pipes and in
ground/water. In switchgear rooms and rooms where
explosions may occur. Can be carefully ploughed down.
AXQJ
Alternative designation
PVC alternative
AKKJ
Bending radius
At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
SE-N1Z1CZ1-AS
Standard
Design
SS 424 14 18
CENELEC HD 603 Part 3 Section L
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1 and
SS-EN 50265-2-1
Temperature range
In continuous operation max. conductor temp. . . . . 70˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken.
Approval
Conductor������������������������� stranded, sector-shaped and
annealed aluminium acc. to
IEC 60228 class 2
Insulation��������������������������� halogen-free compound
Core identification
3-core��������������������������������� brown, black, grey
4-core��������������������������������� brown, black, grey, blue
Filler����������������������������������� halogen-free, extruded compound or plastic tape
Concentric conductor����� annealed copper wires and
counter spiral of copper
Sheath������������������������������� halogen-free compound, black
Marking ��������������������������� e.g. AXQJ 0,6/1 kV 3x240/72 F3
S GREEN LINE CABLES DRAKA
SE “Date”, meter marked.
SEMKO, S-marked EC
Number of cores x cross
section of conductor
mm2
3x50/15
3x70/21
3x95/29
3x120/41
3x150/41
3x185/57
3x240/72
4x50/15
4x70/21
4x95/29
4x120/41
4x150/41
4x185/57
4x240/72
Product Catalogue
Overall diameter
(approx.)
mm
26,4
29,9
33,5
37,4
40,8
45,4
49,7
29,7
33,6
37,7
42,2
46,2
51,3
56,2
Weight (approx.)
kg/100
m
92,1
122,6
158
176
208,5
265,1
333,8
112,7
150,5
194,5
217,1
261,4
329,4
415,2
Standard delivery
length
m
500
500
500
500
500
500
500
500
500
500
500
500
500
500
Standard drum size Article number
K12
K12
K14
K16
K18
K20
K22
K12
K16
K16
K18
K18
K20
K22
1620
1630
1640
1650
1660
1670
1680
1720
1730
1740
1750
1760
1770
1780
Draka Keila Cables | 87
Halogen-free and fire resistant cables
EXQJ 0,6/1 kV
Halogen-free power cable
Application fields
PVC alternative
Halogen-free, no emittance of corrosive gases, low
smoke density in case of fire. Open, fixed installation,
indoors and outdoors, in pipes and in ground/water. In
switchgear rooms and rooms where explosions may occur. Can be carefully ploughed down.
EKKJ
Bending radius
Alternative designation
At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
SE-N1Z1CZ1-U
Design
Standard
Conductor������������������������� solid, round and annealed copper acc. to IEC 60228 class 1
Insulation��������������������������� halogen-free compound
Core identification
3-core��������������������������������� brown, black, grey
4-core��������������������������������� brown, black, grey, blue
Filler����������������������������������� halogen-free compound
Concentric conductor����� annealed copper wires and
counter spiral of copper
Sheath������������������������������� halogen-free compound, black,
meter marked
SS 424 14 18
CENELEC HD 603 Part 3 Section L
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1
Temperature range
In continuous operation max. conductor temp. . . . . 70˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken
Marking
E.g. EXQJ 3X4/4 0,6/1 kV F3 S GREEN LINE CABLES
DRAKA SE “year”.
Approval
SEMKO, S-marked CE
Number of cores x cross
section of conductor
mm2
3x2,5/2,5
3x4/4
3x6/6
3x10/10
4x2,5/2,5
4x4/4
4x6/6
4x10/10
Overall diameter
(approx.)
mm
14
15
16
18,3
14,8
15,9
17,7
19,6
Weight (approx.)
kg/100 m
24,5
31,9
41
61,3
28,1
37
50,7
72,8
Standard delivery
length
m
500
500
500
500
500
500
500
500
Standard drum
size
Article number
K07
K07
K08
K09
K07
K07
K09
K11
2110031002
2110031102
2110031202
2110031302
2110041002
2110041102
2110041202
2110041302
Nominal values unless otherwise specified.
88 | Draka Keila Cables
Product Catalogue
Halogen-free and fire resistant cables
FXQJ 0,6/1 kV
Halogen-free power cable
Application fields
Temperature range
Halogen-free, no emittance of corrosive gases, low
smoke density in case of fire. Open, fixed installation,
indoors and outdoors, in pipes and in ground/water. In
switchgear rooms and rooms where explosions may occur. Can be carefully ploughed down.
In continuous operation max. conductor temp. . . . . 70˚C
Lowest cable temperature under installation. . . . . –20˚C
and below 0˚C special precaution shall be taken
Alternative designation
SE-N1Z1CZ1-R, SE-N1Z1CZ1-S
At fixed mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
At pulling in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D
At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D
Standard
Design
SS 424 14 18
CENELEC HD 603 Part 3 Section L
CENELEC HD 604 Halogen-free Materials
IEC 60754-1, –2 Corrosive Gases
IEC 61034 Smoke Density
Conductor������������������������� stranded and annealed copper
acc. to IEC 60228 class 2
≤ 35 mm2 round
50–240 mm2 sector-shaped
Insulation��������������������������� halogen-free compound
Core identification
3-core��������������������������������� brown, black, grey
4-core��������������������������������� brown, black, grey, blue
Filler����������������������������������� halogen-free, extruded compound or plastic tape
Concentric conductor����� annealed copper wires and
counter spiral of copper
Sheath������������������������������� halogen-free compound, black,
meter marked
Fire propagation class
F3 acc. to SS 424 14 75 and IEC 60332-1
Approval
SEMKO, S-marked CE
PVC-alternative
FKKJ
Bending radius
Marking
E.g. FXQJ 3X240/120 0,6/1 kV F3 (S) GREEN LINE
CABLES DRAKA SE “year”.
Number of cores x cross
section of conductor
mm2
3x16/16
3x25/16
3x35/16
3x50/25
3x70/35
3x95/50
3x120/70
3x150/70
3x185/95
3x240/120
4x16/16
4x25/16
4x35/16
4x50/25
4x70/35
4x95/50
4x120/70
4x150/70
4x185/95
4x240/120
Overall diameter
(approx.)
mm
20,6
23,4
25,8
26,4
29,9
34,3
37,6
41
46,4
51,1
22,3
25,4
28,1
29,7
33,7
38,6
42,3
46,5
52,6
57,6
Weight (approx.)
kg/100 m
94
128,2
162,1
189,8
244,8
332,6
419,5
506,6
633,9
829
112
155,7
198,7
239,8
312,4
424,4
533,5
650,6
811
1060,6
Standard delivery
length
m
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
Standard drum
size
Article number
K11
K11
K11
K11
K14
K14
K14
K18
K18
K22
K11
K12
K12
K12
K12
K16
K16
K18
K20
K22
2115031402
2115031502
2115031602
2115031702
2115031802
2115031902
2115032002
2115032102
2115032202
2115032302
2115041402
2115041502
2115041602
2115041702
2115041802
2115041902
2115042002
2115042102
2115042202
2115042302
Nominal values unless otherwise specified.
Product Catalogue
Draka Keila Cables | 89
Drums
Drum handling guide
The right way to transport, handle and move drums
A cable is a valuable product. The cable transportation package
is usually a drum. The battens on the drum seem thick enough to
remain unbroken. But, with a cable weighing more than 4 tons, it
becomes very vulnerable. If the handling is done correctly, the drum
will protect the cable from transportation damages. If the drum is
damaged, the cable can also be damaged. The damage might not
be discovered until after installation, when repairs can be extremely
expensive.
drum. Keep the drum from touching other drums and well balanced.
Take care not to give any impact to the drum being lowered. In case
a cable drum must be temporarily in a waiting position above the
deck for reason of cargo handling, keep it hoisted and do not put it
down on the deck.
The purpose of these instructions is to tell you how damages can be
avoided by correct drum handling.
Keep the drum upright
Always store and move the drum in an upright position. The drum is
constructed to be handled in an upright position - it will not stand up
to being lifted lying flat. When kept upright, the cable layers will not
entangle and cause problems when the cable is laid. Keep the cable
protected until the cable is used.
Roll in direction of arrows only
Handling with fork-lift truck
The forks of the truck must be longer than the width of the drum, so
that the lagging is not damaged. Different widths of drums should
be painted on the forks enabling the operator to select the correct
position for the drum size. When moving the drum, tilt the truck
mast so that the drum remains in the fork and the points don’t touch
the ground. Raise the forks of the forklift sufficiently 15-20 cm above
the ground. Insufficient raising may cause the drum to be dragged
on the ground and eventually damaged or dropped off the forks if
the ground surface is uneven. Don’t release the drum until the truck
has sopped completely. Don’t push the drum with the truck. Leave
sufficient room between each drum so that the fork doesn’t damage the drum.
Always roll the drum in direction of the arrow. This way the cable will
not unwind and loosen on the drum. But, this does not mean that
the drum can be rolled freely. When the drum must be rolled for
some reason or other, roll it in the direction of arrow over a distance
not exceeding 5 meters. If it is rolled beyond the 5 m limit, the cable
wind will come too tight and cut off the rope holding the cable end.
This will deform the cable and make it unfit for use.
Nail with caution
In case the planks have to be refastened, the nailing should be done
carefully in the middle of the drum flange. If label or something
similar is attached to the drum with nails, make sure that they don’t
touch the cable.
Lift the drum without damage
When lifting the drum, use a shaft through the centre of the drum
and a wire spreader. If these are not available, lift with as long a
wire as possible, so that the sides of the drum are not damaged.
Make sure that the cable head is not pinched between wire and
90 | Draka Keila Cables
Product Catalogue
Drums
Drum handling guide
The right way to transport, handle and move drums
Secure the drums firmly
Fasten the drums firmly
The round-shaped cable drum rolls easily. It is an a very unstable
state because its center section is vacant and the whole weight rests
on its peripheral section. Make sure to use drags to prevent drums
from rolling during storage. Large drums should be lifted from the
base onto triangular or square wedges. The wedges should be positioned by the flanges or the full width of drum. Sideways movement
is eliminated by planks attached to the side of the drum. In case
smaller drums are placed between larger ones, each drum has to
be supported separately to prevent damages.
The drum is fastened to the base through the centre hole or across
the flanges with wires or ropes.
Avoid stacking
Stacking of drums should be avoided. If, however, one is forced to
do this, same size of drums should be positioned exactly on top of
each other.
If smaller drums are stacked on larger drums, planks of the size of
the larger drum is placed in between to protect the flanges. Above
method is recommended even when same size drums are stacked.
Secure drums to be transported
To prevent movement of drums, a combination of wedges and
transportation support should be used and tied down front and rear.
Higher drums should be tied in side direction as high up as possible.
The drums loaded first should rest against the front board (observing shaft weight). If the last drum doesn’t lean against the end board
or the board is not strong enough, the drum must be secured.
Product Catalogue
Don’t drop drums
The drum must not be dropped from the vehicle. The drum is to be
lifted either by winch of fork-lift truck as mentioned in “lifting the
drum”. If above mentioned equipment is not available, best possible
conditions must be created to unload the drums from the vehicle. A
platform of the same height as the vehicle or a point in the terrain
will guarantee that no damage will occur. Make sure when unloading
that the drum doesn’t strike another drum.
Draka Keila Cables | 91
Drums
Drum dimensions
and weights
D
A
C
E
B
Drums
type
5C
6A
6C
7E
8E
9F
9FV
11G
11GV
13G
15G
16L
18M
20P
22P
22P5
26U
26U8
28W
28WO
30Y
32Z
K6
K7
K8
K9
K11
K12
K14
K16
K18
K20
K22
K24
K26
K28
K30
92 | Draka Keila Cables
Dimensions
mm
A
500
600
600
700
800
900
900
1100
1100
1300
1500
1600
1800
2000
2200
2200
2600
2600
2800
2800
3000
3200
600
700
800
900
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
Weight
kg/drum
B
500
400
500
610
610
660
675
725
755
760
760
970
1025
1155
1155
1155
1455
1455
1610
1610
1810
1970
468
580
580
630
762
982
982
1018
1075
1190
1190
1205
14 48
1650
1800
C
250
250
250
325
375
425
425
500
500
600
700
800
1100
1100
1200
1500
1500
1800
1500
2000
2200
2400
250
325
375
425
575
675
800
950
1100
1300
1400
1400
1500
1500
1500
D
400
300
400
500
500
550
550
600
600
600
600
800
850
960
960
960
1200
1200
1300
1300
1500
1600
400
500
500
550
650
850
850
850
850
1000
1000
1000
1200
1350
1500
E
55
55
55
55
55
82
82
82
82
82
82
82
82
82
82
82
123
123
123
123
123
132
75
75
75
75
106
106
106
106
132
132
132
132
132
132
132
10
10
16
20
26
40
50
70
85
105
150
185
260
350
445
460
805
830
1050
1100
1300
1900
12
20
25
34
55
90
115
195
230
340
410
450
900
1180
1500
Product Catalogue
The mission of Draka Keila Cables is to be a profitable
Draka enterprise. We have a competent sales organization that is targeted to the customers and we produce
and sell a wide range of cable products to the present
and future information and electricity networks.
We wish to achieve the satisfaction of customers,
employees and owners by making decisions that would
enable the environment-friendly development of Draka
Keila Cables by minimizing our environmental impacts
and improving the effectiveness of our management
system constantly.
Upon the implementation of ISO 9001:2008, ISO
14001:2004 and OHSAS 18001:2007 requirements,
Keila Kaabel proceeds from the needs of the customers and the instructional requirements.
AS Draka Keila Cables
Paldiski Road 31
76606 Keila
Estonia
Phone +372 674 7466
Fax +372 674 7468
www.draka.ee
Member of Prysmian Group
www.prysmian.com