Uploaded by junior99

DOK-435E SoftwareUpdate

advertisement
Software Update
Procedure
DOKDOK-435E / Rev. 1.00 GE / Juli 2001
Sening Systems
Sening Systems
Software Update
Procedure
Contents
1 General 1
1.1
1.2
How to Use this Manual................................
Manual................................................................
................................................................................................
......................................................................
......................................1
...... 1
Initial Rema
Remarks
rks................................
rks................................................................
................................................................................................
...................................................................................
...................................................1
................... 1
2 Software Update by Download ................................................................
................................................................................................
.................................................................
................................. 2
2.1
2.2
2.3
Danger Warning................................
Warning................................................................
................................................................................................
.................................................................................
.................................................2
................. 2
Required Hardware................................
Hardware ................................................................
................................................................................................
............................................................................
............................................2
............ 2
Procedure ................................................................
................................................................................................
.........................................................................................
.........................................................3
......................... 3
3 Software Update by Exchanging the EPROM Chip
Chip................................
................................................................
.....................................................................
.....................................6
..... 6
4 Warranty and Service ................................................................
................................................................................................
..............................................................................
..............................................9
.............. 9
Descr. No:: DOK-435E
Printed on paper free of chlorine
Rev. 1.00 GE / Datum: 10.Jul.2001
Seite i
Sening Systems
Software Update
Procedure
1 General
1.1 How to Use this Manual
This manual contains multiple information. In order to help you find the information you need, the
following orientation aids have been used:
• Icons
The information in this manual ranges from absolutely required protective measures and
standardised requirements to concrete operating steps and good advice. For easy reference the different types of information are marked by pictographs.
The intention is not only to increase the reader’s attention, but also to help to identify the
desired information quickly. For this reason the respective icon symbols are closely related
to the contents of the text .
In this manual you will find the following icons:
Danger! In this case: Danger of explosion.
Threat of disruption. Action that may damage the equipment.
§
Legal hint. Action that may have legal consequences
Operation step,
step concrete handling instruction
☺
FeedFeed -back positive,
positive e.g. “Now the main menu appears”
FeedFeed -back negative,
negative e.g. “If an error message appears … “
Additional information, advice, tip
tip, e.g. “Further details in chapter XX”
⌦
Optional or special case
Function / Functional description
description
•
Key word register at the end of the documentation helps to locate the various topics.
1.2 Initial Remarks
When updating the software of the MultiFlow (by downloading it or by exchanging the EPROM)
the following documents should be at hand, or have been printed out beforehand:
•
Parameter list print-out
•
Parameter list on chip card
•
Latest printout of electronic W&M Seal
•
Tour report and event report, if available
•
Delivery Note / Invoice
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 1 of 10
Sening Systems
Software Update
Procedure
2 Software Update by Download
The following chapter describes how to update the software for a MultiFlow.
With other devices (which support the download feature) the procedure is analogous.
2.1 Danger Warning
EX instructions for construction/installation (e.g. DIN EN 6007960079 -14; VDE 0165)
must be strictly followed!
Generally a laptop
lap top computer is not explosion proof, and therefore must not be
o p erated within areas liable to explosion (e.g. driver’s cab)!
The protection circuits of the Sening components are laid out for power supply voltage on
board of a truck (24V). For safety reaso
reasons
ns only laptops powered by
batteries (lap
(la p top power supply voltage <24V) shall be used, therefore.
It is strictly prohibited to connect a mainsmains-powered laptop or PC!
*** Any kind of manipulation, either mechanical or electrical, is prohibited.***
EXPLOSION HAZARD
•
Instructions on EX signs must be strictly followed.
•
It is not permissible to fit any additional components in the housings or in the terminal boxes
(e.g. additional terminals), since this would contravene the device approval.
•
Any right to claim warranty is waived if this rule is not adhered to.
2.2 Required Hardware
Connect PC Adapter (F. A. Sening Part No. MFLOW-PCADAP) to the printer cable of the Sening
system instead of the printer. In addition you need a serial cable with adequate length provided
with the following seizures:
9 point SUB-D female plug
to connect to the serial port
of the laptop (normally COM1)
25 point SUB-D male plug
to connect to the PC adapter
Pin 5
Pin 7
Pin 2
Pin 3
Pin 3
Pin 2
Any standard modem cable (1:1 connection, not a cross-over cable!) is equipped with this kind of
seizure.
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 2 of 10
Sening Systems
Software Update
Procedure
2.3 Procedure
Check correct functioning of the system.
Print out a list of all parameters.
Save parameter setting to the chip card ( Parameter 4.5.2. ).
Switch off all devices involved (e.g. laptop, NOMIX, SPD, MultiFlow, MultiSeal, EMIS).
Disconnect RS232 printer cable from the printer and connect same to the PC adapter at
the side marked „MultiFlow“.
Connect the earth wire of the PC adapter
(Connect the black terminal of the PC adapter with the ground cable).
Connect the laptop and the PC adapter with the modem cable (as described in 2.2 ).
Place the laptop outside any area with explosion hazards.
Do not operate the laptop with mains voltage, but
bu t equipped with batteries (for lap
la p top
power sup
su p ply voltage <24V) or on board voltage only.
Put laptop and Sening components into operation.
Start the download software (UDO.EXE) on the
laptop. This program is
available upon request
from our Service department.
If software program is not
yet installed, install same
from the software disk.
Choose the command
‘Verbinden‘ in the
‘Verbindung‘ menu.
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 3 of 10
Sening Systems
Software Update
Procedure
The download software
enables a connection to the
device (e.g. MultiFlow) and
prepares the download.
Choose the command
‘Download‘ in the
‘Speicher‘ menu.
The software will open a
window to select the file.
Select the file for download
and click “OK“.
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 4 of 10
Sening Systems
Software Update
Procedure
Download will take about 5
minutes.
The progress of download
is visible by the blue bar at
the bottom of the window.
Finish download program
by clicking the button
‘Abbrechen’.
Switch off MultiFlow, connect printer.
Switch on and initialise MultiFlow ( Parameter 4.4. ).
Read out parameter from chip card ( Parameter 4.5.1. )
Print and compare parameter list.
Print and compare delivery note.
Set and print out W&M seal.
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 5 of 10
Sening Systems
Software Update
Procedure
3 Software Update by Exchanging the EPROM Chip
Check correct functioning of the system.
Print out a list of all parameters.
Make a note of the receipt ID ( Parameter 3.1.9. ).
Save parameter setting to the chip card ( Parameter 4.5.2. ).
Switch off the voltage of MultiFlow and printer.
A1 Model: Open round Ex-housing.
Respective instruction (Drawing No. 51.351100) must be followed strictly!
A3 Model: Open operator terminal, disconnect plug connector.
Take out electronics mounted on aluminium base plate.
The EPROM is located on the back of the base plate.
MFLOW
Ver. X.XX
(X.XX)DE
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 6 of 10
Sening Systems
Software Update
Procedure
Remove old EPROM by using adequate tool only,
e.g. EPROM extractor supplied by RS Components - part. no. 404-727
or F.A. Sening Part No. 7351002
Place both claws of the extractor into the socket, press EPROM extractor slightly against
the socket and push the legs of the EPROM extractor with your thumb and index finger
(see picture). By means of the self-acting leverage effect the EPROM will then be pulled
out automatically.
Note: Do not pull the legs of the tool to remove the EPROM!
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 7 of 10
Sening Systems
Software Update
Procedure
Insert the new EPROM in the socket.
Note the positioning of the flattened corner (bevelling):
MFLOW
Ver. X.XX
(X.XX)DE
Push EPROM into the socket with a slight and steady movement.
Do not execute any special force!
Re-assemble the devices (grease threads!).
Switch on and initialise MultiFlow ( Parameter 4.4. ).
Read out parameters from chip card ( Parameter 4.5.1. ).
Check receipt ID ( Parameter 3.1.9. ).
Print out new parameter list and compare with old one.
Print out new delivery receipt and compare.
Set and print out W&M seal.
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 8 of 10
Sening Systems
Software Update
Procedure
4 Warranty and Service
In addition
addition to the dealer's legal warranty in the purchase agreement we give the end user a warranty for this device on the following conditions:
1. The warranty period is twelve months and starts at the time of delivery of the device
by F. A. Sening. With electronic products the registration form must have been received
at Sening fully completed and signed by the installation department.
2. The warranty includes the rectification of all device damage or defects occurring within
the warranty period and which can be shown to be due to material or production faults.
The warranty does not include:
-
slight deviations from the intended quality which are insignificant for the value or usefulness of the device,
-
damage or defects due to connection other than as specified, improper handling or nonobservance of the installation guidelines and instructions for use,
-
damage from the chemical and electrochemical effects of water or other liquids, electrical or electromagnetic influences and generally from abnormal ambient conditions,
-
damage due to external effects such as damage in shipment, damage due to shock or
impact, the effects of the weather or other natural phenomena.
3. The right to claim under warranty becomes invalid if repairs or tampering have been carried out by persons not authorised by us for the work or if our devices have been fitted
with supplementary parts or accessories which are not suitable for our devices and not
released by us for that purpose.
4. The warranty service is carried out free of charge and, at our choice, by either repairing
defective parts or replacing them by perfect parts. Replaced parts become our property.
5. During the first six months of the warranty period the warranty service is carried out without billing. Thereafter, travelling times, travelling costs and working time for the service
staff and any transport costs occurred are billed or not reimbursed.
6. Work under warranty does not imply any lengthening of the warranty period nor does it
initiate a further period of warranty. The warranty period for installed replacement parts
terminates with the end of the warranty period for the complete device.
7. More far-reaching or additional claims, in particular those for compensation of losses or
consequential losses outside of the device are expressly excluded, provided no liability is
deemed mandatory in law.
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 9 of 10
Sening Systems
Software Update
Procedure
Important Note
All explanations and technical details given in this documentation have been produced and edited by the author with the greatest care. However the possibility of errors cannot be completely
eliminated. FMC Measurement Solutions - F. A. Sening GmbH would be very grateful for the
notification of any errors found.
Our service team would be pleased to advise and help you.
They can be reached under:
Regentstrasse 1
D-25474 Ellerbek
Tel.: +49 (0) 4101 / 304 – 0 (Switchboard)
Tel.: +49 (0) 4101 / 304 – 288 (Hotline)
Fax: +49 (0) 4101 / 304 – 255 (Service)
Beschr.-Nr: DOK-435E
Gedruckt auf chlorfrei gebleichtem Papier
Rev. 1.00 GE / Date: 10.Jul.2001
Page 10 of 10
Related documents