NIS / ODs
Final Decisions
May 2019
SITE: Asphalt driveway w/concrete patch
Final Decision
NOD
SITE – Bump repaired with concrete
Final Decision
NOD
SITE: Asphalt driveway w/concrete patch
Final Decision
NOD
SITE – Light pole – NIS > H/S > Exposed wires
Final Decision
NIS-Site/H&S/Electrical/Exposed
Wires-Tape repair
BE – Walls – transparent tape used
Final Decision
NIS-L2-Tape over hole
BE – Walls – Siding > Asbestos tiles
Final Decision
NIS-L1-Paint
NIS Repair (Paint) – Bldg Exterior /
Walls / Stain or peeling paint / Less
than 50% of a single wall / L:1 /
(Comment: Proper repair not
finished – requires paint)
BE - Doors - Entry door – nails used at bottom
Final Decision
NIS-L3-Repair with nails
NIS Repair – Bldg Exterior / Door /
Entry Door leads to outside / Surface
damage / Holes / Does not result in
H&S concern / L3 / (Comment:
Surface delamination improperly
repaired with nails)
NOTE: if inspector chose <Door has significant peeling,
cracked, or no paint> instead of <Entry door has hole> same outcome in decision tree.
BE – Walls – not repaired yet (not L2 but L3)
Final Decision
Not NIS-Could be L2 or L3 depending
on depth of hole
Deficiency not a NIS Repair
Bldg Exterior / Walls / Holes /
Greater than ½” diameter < sheet of
paper / L2 / (Comment: Hole in wall
next to pipe)
BE – Walls – repair done sealing w/concrete
Final Decision
NOD
BE – walls – repair w/concrete around AC unit
Final Decision
NOD
BE – Wall – Siding Repair – screws used
Final Decision
NIS-L2-Inadequate material
NIS Repair (Paint) – Bldg Exterior / Walls /
Missing Pieces / A single missing piece / L2 /
Comment: Inadequate material used for
repair.
BE – Siding repaired – glue used
Final Decision
NIS-L2-Inadequate material
NIS Repair (Paint) – Bldg Exterior / Walls /
Missing Pieces / A single missing piece / L2 /
Comment: Inadequate material used for
repair.
BE - Gas pipe touching disconnect box / cannot be open (no lock / zip tie)
Final Decision
Hazards Other
Not a NIS Repair
Hazards Other – Gas line in contact with
electrical disconnect box)
BE – Door – metal plate on both sides – see next slide.
Final Decision
NOD
BE – Storage door – NIS?
Final Decision
NOD
BE – Walls - sidings with different colors
Final Decision
NOD if consistent throughout
BE – Roof – different shingle colors
Final Decision
NOD if shingle style and color are as
close as possible
BE – Roof – repair w/different color
Final Decision
NOD-Shingle color is as close as
possible
BE – Roof shingles – different color
Final Decision
NOD-Shingle color is as close as possible
BE – Porch Column >LBP encapsulated (not cover up)
Final Decision
NOD-No area to record under Rapid
4.0
Note – No place to record deficiency on RAPID 4.0. Need
to address during COMP Bulletin update.
CA – Walls (Janitor’s room) – wall protected w/plexiglass
Final Decision
NOD-Wall protected from damage
CA – Walls (Trash Collection Area) – protected w/wood guard
Final Decision
NOD-Wall protected from damage
CA – Walls (Trash Collection Area) – protected w/metal guard
Final Decision
NOD-Wall protected from damage
CA – Hallway Door – two types of paints > NIS L3?
Final Decision
NOD
CA – Door in hallway
Final Decision
Insignificant area
UNIT – doors – paint peeling / L3?
Final Decision
Insignificant area
UNIT – Entry door (inside surface With weather strip mounted on door)
Final Decision
L3-NIS-Incorrect use of weather strip
NIS Repair – Unit / Doors / Hallway / Entry
door to unit / caulking is missing deteriorated,
door is not weather resistant (if designed to
have seals) / L3 / Comment: NIS weather strip
mounted incorrectly.
UNIT – Entry door (inside surface with weather strip mounted on door)
Final Decision
NIS-L3-Incorrect use of weather strip
NIS Repair – Unit / Doors / Hallway / Entry
door to unit / caulking is missing deteriorated,
door is not weather resistant (if designed to
have seals) / L3 / Comment: NIS weather
strip mounted incorrectly.
UNIT – Flue pipe encapsulated for protection - NIS?
Final Decision
NOD or Hazards Other-Inspector
Judgement
NOD – No Defect / or Hazards Other (inspector
judgement on determining if cover is safe /
adequate on hot pipe)
UNIT – Flue pipe Encapsulated (not cover up)
Final Decision
NOD or Hazards Other-Inspector
Judgement
NOD – No Defect / or Hazards Other (inspector
judgement on determining if cover is safe /
adequate on hot pipe)
UNIT – Bedroom wall – Smoke Detector removed – missing SD or NIS?
Final Decision
L3-Missing smoke detector-If another smoke
detector is on the same level, this would be
NIS wall repair L1
Unit / Smoke Detector / Location / Missing / There is NOT
another functioning Smoke Detector on the same level/ It
CAN be separated by other areas of the level by doors/ L3
Or
NIS Repair / There is another functioning Smoke Detector
on the same level / L3 / Comments: – NIS repair – missing
Smoke Detector was patched with an outlet plate
UNIT – Door – NIS or Hole
Final Decision
NOD
UNIT – Doors - Entry door – NIS L3
Standards Committee Final Decision
NOD
UNIT – Doors - Bathroom door – NIS L3?
Final Decision
NIS-L3-Appears to be unworkmanlike repair
UNIT – Doors – Bathroom door - NIS L3
Final Decision
NOD
UNIT – Doors - Bathroom door – NIS – L3 ?
Final Decision
NIS-L3-Appears drywall compound used to
repair door
NIS Repair – Unit / Doors / Bedroom / All other doors
(includes closet or other interior doors) / surface
damage / L3 / Comment: NIS repair – work on repair
not completed.
UNIT – Bedroom door -NIS or hole in door – L3
Final Decision
NIS-L3-Wall protector used to cover
hole in door-NOD only if an adjacent
door opens against this area
Mechanical stopper replaced with Rubber stopper
Final Decision
NOD-If all evidence of mechanical
stopper has been removed
UNIT – Bathroom – Rubber stopper exists (Many QA records as L3???)
Final Decision
NIS-L1-Mechanical stopper inoperable
NIS Repair – Unit / Bathroom items /
Bathroom / Shower or tub / Stopper
missing / L1 / Comment: NIS repair –
stopper replaced with rubber stopper –
trip level still in place and INOP
UNIT – Bathroom – NIS Mechanical stopper replaced by Rubber stopper
Final Decision
NIS-L1-Water stop rod should be
removed if rubber stopper in use
NIS Repair – Unit / Bathroom items /
Bathroom / Sink / Stopper missing / L1 /
Comment: NIS repair – stopper replaced
with rubber stopper – push/pull level
still in place and INOP .
UNIT – Floor – different color tiles >5% - NIS?
Final Decision
NOD
Note: Close enough in color. CB needs clarification. Inspector
judgement on color closeness or mismatched tile percentages? In
this case, we used inspector judgement, colors were close enough.
Therefore, the mispatched rule does not apply.
Inspector note on pages 5, 58 and 75 of CB
Mismatched floor covering pictures on pages 66 and 84 of CB.
UNIT – Walls – repair covered w/wood
Final Decision
L2-NIS-Wall repair with wood
NIS Repair – Unit / Doors / Walls / Kitchen /
Holes / Larger than a sheet of paper, cannot
see through hole / One wall is affected / L2 /
Comment: NIS repair – wall under kitchen sink
improperly repaired with wood.
UNIT – Kitchen - Countertop all units’ stovetops permanently removed &
patched with exactly same material (Formica) as the countertop.
Final Decision
NOD-Appropriate remodeling
material
UNIT – Doors – Entry door (inside surface) – NIS or Hole???
Final Decision
OD-L3-Hole in door
Not NIS Repair
Unit / Doors / Hallway / Entry door to unit / Surface damage
/ Entry door has hole / Condition does not result in H&S
concern / L3 / Comment: Hole on inside surface of entry
door caused by door stopper.