CLOSE Select your system from the drop down box below then click on the GO button Select System GO Navigation Click on the HOME icon, located top right of each page, to . return to this page. Click on the BACK icon to return to the product home page. Click on the INFORMATION icon for an overview of the product. X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information blication 67 Table Control Area PRE INSTALLATION MANUAL FLEXI-DT System Cabinet DIGITAL TABLE Detector Support Assembly (DSA) Flexi DT Digital Table Patient Barrier OTS Wall Stand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Jedi Generator: Generates the power used by the x-ray tube Corona 2 Board controls the system power on, off and reset functions and also serves as a CAN Hub for the system’s CAN buses. Power Distribution Unit (PDU): Distributes 120Vac & 230Vac around the system Bulkhead Halo Board Contains relays which are used to switch power to the system. The relays are controlled by the Corona 2 Board. On/Off Switch System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Control Monitor Patient List/ Image Monitor Exposure Switch Keyboard Radiographic Control Interface Module (RCIM) Click for details Mouse System and Image Processing Computer (aka Magic PC) Wall Plate (located under counter) CD-RW/DVD ROM Drive X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Motorised Movements Vertical Longitudinal (along overhead rails) Lateral (along overhead rails) Column rotation (rotates at top of column not at the goose neck) Xray Tube Angulation Carriage Column Rotation Telescopic Column Vertical Tube Angulation X-ray Tube User Interface Console Click for details Collimator Click for details X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Wallstand Bucky tilts to horizontal Detector Angulation and SID Display Vertical Lock Release Wall Bucky Horizontal Lock Release Wall Stand Handheld Control Click for details Detector Support Assembly (DSA) contains power supply and conditioner (chiller) for wall stand detector Lon Wall Stand (Standard version) ger Arm Extended Arm Version of Wall Stand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Enable Button Lit= movements disabled OFF= movements enabled Floating Table-top Grid Detector handle Emergency Movements Off Button When pressed disables all room movements Table Up/Down Table Down Table Up Table-top Locks Release (longitudinal & lateralfloating table-top mode) X-ray Photo Tour- Rev.2 by E.Singleton CH CLOSE 3. Put the template over the tabletop. It has to fit between the two metal frame guides. Then place the table between the detector and the suspension, as in Figure 13. 5.1. SAFETY The Flexi DT Digital Table This portable table is designed to be used with the OTS and wallstand. The table has motorised movements and can be powered from a 120/230Vac outlet or from its internal 24Vdc batteries. The table is temporarily secured to the floor with pins, which are interlocked to prevent FLEXI-DT. DIGITAL TABLE SERVICE MANUAL exposures if not in place. REVISION 5 P/N S0015068 The table also has a collision detection device to prevent collisions with the detector. 2 Lateral Drive The FLEXI-DT the safety locks. 5.1.1. EMERGE Flexi DT Table with Wall Stand Figure 13 9 3 Figure 12 Longitudinal Drive 8 Figure 1 7 1. Elevating Base 2. Table-top 4 11 of the table (with the template on it) must be aligned with the collimator 4. The centre 3. Control Panel cross (Figure 14) as with the detector, move the table until getting the collimator 4. Emergency Stop cross over the center align cross of the template, as in Figure 15. 5. Wheels 6 Electronics 6. Wheel Brakes 1 7. Pins 8. Pin Lodging 9. Safety Locks 10. Pedals 5 10 11. IR Device Flexi DT Table Collimator cross Figure 53 Control Panel X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Patient barrier is placed in front of the wall-stand. Its purpose is to prevent the patient from coming in contact with the moving wall-stand detector during certain studies. Patient stands on this platform Barrier attaches to the floor with steel pins Patient Barrier X-ray Photo Tour- Rev.2 by E.Singleton CLOSE LEDs Longitudinal Lock Release Ready Image Pasting Prep Exposure Inhibit Manual Collimation Lateral Detent SID Detent Tube Angulation Lock Release Lateral Lock Release Touch-screen Display Interlock Override Button Detent Mode Active LED Vertical Lock Release Column Rotation Lock Release All Transitional Locks Released LED Collimator Field Light Detent Select OTS User Interface Console All Locks Release Button X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Image Head Remote Touch Panel (RTP) Monitor Supports Generator Positioner X-ray Tube, Collimator & DAP Collimator Control Cabinet Control Area X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Upper Assembly Area includes CPU board, Room Interface board and Photo-timing AEC board Inverter Control Board Filament & Power Supply boards Inverter Assembly Rotor Driver Board High Voltages (>600Vdc & 480Vac) are present in this area Power Input and Resonant Inverter Area High Voltage Tank Generator Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Dose Area Product (DAP) Chamber Ralco Collimator with: Iris 3 Spectral Filters 2 Vascular Contour Filters 1 Ruler Filter X-ray Tube & Collimator Varian G1592 (DSA) or G1092 (RF) X-ray Tube X-ray Tube Oil to Air Cooler (only used with G1592 x-ray tubes) X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Optics Assembly CCD Camera Image Intensifier Power Supply Image Intensifier Image Head X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Digital Monitor Generator Touchscreen monitor Radiographic Exposure Hand switch Digital Keyboard and Mouse Positioner Console Click for details SVGA Splitter (used to drive the control room and in-room digital monitors) Fluoro Footswitch Isolation Transformer (used for PC and monitor power) Radiographic Exposure Footswitch Control Area Digital Image Processing Computer X-ray Photo Tour- Rev.2 by E.Singleton CLOSE In-room Monitor Ceiling Suspension for two Flat Panel Monitors In-room Monitor Ceiling Suspension for a single Flat Panel Monitor In-room Monitor Cart for Flat Panel Monitor X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Gantry (contains positioner electronics) Positioner Monitor (displays positioner movement values and interlock information) Table-top C-Arc Positioner X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Touch-screen Monitor (basic Generator and Digital functions can be performed from here) Positioner Console Click for details Radiographic Exposure Footswitch Fluoro Footswitch Remote Touch Panel (RTP) X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on a selection box below to see switch functions Home & Preset Positions AP/PA , Emergency Off & Collision Override Collimator & II Movements X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Image Head Intelligent Digital Device (IDD) System Cabinet Positioner Cabinet Wallstand Positioner Overhead Tube Suspension Monitor Supports Control Area X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Digital System (Saturn): Responsible for Image Processing and Storage (hard disk can store up to 8,000 images). Windows 95 Operating System Athena is the applications software Accessory Rack: Contains miscellaneous circuitry used for controlling the power state of the system. High Voltage (>600Vdc) is present in the generator even before the system is turned on at the console Jedi Generator: Generates the power (up to 85kW) used by the x-ray tube Power Distribution Unit (PDU): Distributes 120Vac & 230Vac around the system UPS: Provides power to the PCs (Digital and Magic) during a hospital power failure Cable Bulkhead A25 ON/OFF Switch System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE A7 Table Angulation Panel (Table Tilt Drive) A22 Longitudinal IDD Drive CAN Amp (Power Assist) A26 Lateral Table-top Drive Board A23 Vertical IDD Drive (SID- Power Assist) CAN Amp A21 Relay Panel Contains relays for longitudinal table-top drive A20 Positioner I/O Board: Converts analog signals from the Positioner to CAN messages and CAN message from the controller PC back into analog signals A28 Power Supplies (3) (+24V) (+12V) (+5V,+15V,-15V) Positioner Cabinet A29 Power Bulkhead X-ray Photo Tour- Rev.2 by E.Singleton CLOSE In-room Monitor Ceiling Suspension for two Flat Panel Monitors In-room Monitor Ceiling Suspension for a single Flat Panel Monitor In-room Monitor Cart for Flat Panel Monitor X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Off (disables power to Table, OTS & Wallstand) Bucky Tray Table Controls Click for details Patient Step (blocks table tilt when pulled out) Positioner X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Grid (behind the cone): can be driven in or out of the field. Used to improve image contrast by attenuating the off focal radiation Image Intensifier behind cover IDD Console Click for details IDD in Field Latch CCD Camera and Optics Assembly behind this cover Cone: can be driven in or out of the field. Used to compress anatomy X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Integrated User Interface (IUI) Touch screen (Magic PC Display) RCIM Click for details In-room wall plate for monitor connections Digital (Saturn) Monitor Video Switch: switches video input to monitor between DVD and Digital PC System PC (Magic PC): Functions: Control of the generator Control of Positioner movements using the CAN Bus User Interface OS: Linux IUI Keyboard used for Service mode and for entry of Protocol name Exposure Switch DVD Recorder Control Pad DVD Recorder Digital Keyboard and Mouse Accessory Box containing Daxten K/B Mouse Extender Remote version 1034-121PL X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Carriage Assembly Bridge Lateral Movement X-ray Tube (MX100) (behind cover) Cable Rail User Interface Click for details Collimator Click for details Longitudinal Movement Rails Overhead Tube Suspension (OTS) OTS Bridge and rails: Allows lateral and longitudinal movement of the Tube Suspension. Potentiometers used for positional feedback. X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Patient Handles Wallstands The Precision 500D has the option of two types of wallstand, Tilting and Non-tilting. Early Precisions (approximately May 2002September 2004) had the option of: SG-60 (non tilting) SG-100 (tilting) Later versions of the Precision have the option of: SG-80 (non tilting) SG-120 (tilting) Attached to Wall Differences SG-60 and SG-100 are attached to the wall and do not have a patient handle, whereas SG-80 and SG-120 are floor only mounted with patient handles. The Bucky tray can be mounted on either side (field changeable) SG-100 SG-120 SG-100 Wallstand with the bucky tilted X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Left Screen Click for details Vertical & Horizontal Image reverse buttons Right Screen Click for details Collimator Controls Fluoro and Record Exposure Switches Table Angulation Knob Longitudinal tabletop drive Switch Vertical and Longitudinal Power Assist handle IDD Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tube selected indicator Wallstand receptor select kV Readout mAs Readout Not Used kV change buttons Table bucky receptor select mAs change buttons SID Readout Table-top receptor select Tube Angle Readout Longitudinal Lock Lateral Lock Angulation Lock Detent Lock or release the detent magnetic lock. Normally open self–lock type button. Vertical Lock All Locks Indicators- Lit means: Ready Exposure Manual Hold Collimation OTS User Interface X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Generator Positioner Positioner Cabinet OTS Wall Stand Monitor Supports Control Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE CPU board and Stepper Motor control board (ASSI) (behind the Interface Board) Group 25 Interface Board Group 25 Stepper Motor Controllers Group 24 High Power DC Motor Controls Group 23 Power Input Rack Group 22 Optional 277Vac to 230Vac Input Voltage Transformer (22TR3) Digital Image Chain to Generator Interface Module (GIM) Positioner Cabinet Isolation Transformer for Digital PC X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Upper Assembly Area includes CPU board, Room Interface board and Photo-timing AEC board Inverter Control Board Filament & Power Supply boards Inverter Assembly Rotor Driver Board High Voltages (>600Vdc & 480Vac) are present in this area Power Input and Resonant Inverter Area High Voltage Tank Generator Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE In-room Monitor Ceiling Suspension for two Flat Panel Monitors In-room Monitor Ceiling Suspension for a single Flat Panel Monitor In-room Monitor Cart for Flat Panel Monitor X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Generator Touchscreen monitor Digital Monitor Positioner Console Click for details Digital Keyboard and Roller ball Digital Image Processing Computer Fluoro Footswitch Control Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Carriage Telescopic Column X-ray Tube OTS Control Panel Click for details Collimator Click for details OTS X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tube Stand X-ray Tube Table-top Collimator Click for details Spot Film Device (SFD) Cone (Palpator) Table Control Panel Click for details Image Intensifier and CCD Camera behind this cover Foot Board Table Base Positioner X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Patient Handle Bucky Bucky Tray Wall Stand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on a selection box below to see button functions Movements Display Collimator & II Exposure & Technique selection Tomo Positioner Console Nical X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Table System Cabinet Overhead Tube Suspension Wall Stand Control Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Jedi Generator (behind Interface Board) System Interface Board Jedi Generator On/Off Breaker Power Distribution System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tomo Attachment Movements Enable Button Lit= movements disabled OFF= movements enabled Tomo Console Click for details Floating Table-top Emergency Movements Off Button When pressed disables all room movements Bucky Table-top Locks Release (longitudinal & lateral- floating tabletop mode) Table Up/Down Table Table Down Table Up X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tomo-Link Drive Unit LED: On when OTS is in lateral detent Wallstand detent magnetic strip Lateral Movement Longitudinal Movement Carriage Assembly X-ray Tube (MX100) (behind cover) Magnetic sensor electronics behind cover, used to decode magnetic detents User Interface (OCS) Click for details Collimator Click for details Overhead Tube Suspension (OTS) Lateral tabletop detent magnetic strip OTS Bridge and rails: Allows lateral and longitudinal movement of the Tube Suspension. X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Bucky Tray Wall Stand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE OFF and ON Buttons Technique change buttons Prep/Expose Buttons Prep/Expose Handswitch Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tube selected indicator Wallstand receptor select kV Readout mAs Readout Tomo receptor select kV change buttons Table bucky receptor select mAs change buttons SID Readout Table-top receptor select Tube Angle Readout Longitudinal Lock Lateral Lock Angulation Lock Detent Lock or release the detent magnetic lock. Normally open self–lock type button. Vertical Lock All Locks Indicators- Lit means: Ready Exposure Manual Hold Collimation OCS User Interface X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Control Console System Cabinet U-Arm Positioner X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tube Up/Down (SID) User Interface Click for details X-ray Tube Collimator Click for details U-Arm U-Arm pivot point Grid Detector Assembly pivot point Digital Detector U-Arm Control Panel Click for details U-Arm Positioner Emergency Movements Off Button When pressed disables all movements X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Sedecal Generator U-Arm Motor Controllers Power Distribution System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE System and Image Processing Computer (aka Magic PC) Control and Image Monitor Mouse Keyboard Exposure Switch Control Remote Interface Board (CRIB) Click for details Remote Control Click for details Control Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Table Control Area System Cabinet Detector Support Assembly (DSA) OTS Wall Stand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Image Detection Controller (IDC) 1 Table Corona Board controls the system power on, off and reset functions . IDC 2 Wall Stand Jedi Generator: Generates the power used by the x-ray tube Bulkhead Power Distribution Unit (PDU): Distributes 120Vac & 230Vac around the system Halo Board Contains relays which are used to switch power to the system. The relays are controlled by the Corona Board. On/Off Switch System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Control Monitor Patient List/ Image Monitor Exposure Switch Keyboard Radiographic Control Interface Module (RCIM) Click for details Mouse System and Image Processing Computer (aka Magic PC) Wall Plate (located under counter) CD-RW/DVD ROM Drive X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Carriage Assembly Telescopic Column Bridge Motorized SID movement X-ray Tube (MX100) (behind cover) Longitudinal Movement Cable Rail User Interface Click for details Collimator Click for details Lateral Movement Rails Overhead Tube Suspension (OTS) OTS Bridge and rails: Allows lateral and longitudinal movement of the Tube Suspension. Potentiometers used for positional feedback. X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Wallstand Bucky tilts to horizontal Detector Angulation and SID Display Wall Bucky Horizontal Lock Release Wall Stand Handheld Control Click for details Detector Support Assembly (DSA) contains power supply and conditioner (chiller) for wall stand detector Vertical Lock Release Wall Stand Rear view of Wall Stand Bucky X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Enable Button Lit= movements disabled OFF= movements enabled Floating Table-top Grid Detector handle Emergency Movements Off Button When pressed disables all room movements Table Up/Down Table Down Table Up Table-top Locks Release (longitudinal & lateralfloating table-top mode) X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Tube selected indicator Wallstand receptor select kV Readout mAs Readout Not Used kV change buttons Table bucky receptor select mAs change buttons SID Readout Table-top receptor select Tube Angle Readout Longitudinal Lock Lateral Lock Angulation Lock Detent Lock or release the detent magnetic lock. Normally open self–lock type button. Vertical Lock All Locks Indicators- Lit means: Ready Exposure Manual Hold Collimation OTS User Interface X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Image Head Spot Film Device (SFD) System Cabinet Positioner Cabinet Positioner Overhead Tube Suspension Image Processing System Control Area X-ray Photo Tour- Rev.2 by E.Singleton CLOSE TV Camera Controller and Video Processor (VIC) System Controller (Titan) Exposure Control Module (ECM) SCPU Generator High Voltage Transformer System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Interface Bulkhead Table and Spot Film Device Controller Table Angulation Controller Positioner Power Distribution Positioner Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Off (disables power to Table, OTS & Wallstand) Bucky Tray Table Controls Click for details Positioner X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Optics Assembly Image Intensifier Power Supply Camera Image Intensifier Spot Film Console Click for details Cassette Tray Image Head and SFD X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Integrated User Interface (IUI) Touch screen Power On/Off Exposure Switch Reset X-ray ON indicator Selection Wheel Control Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Bridge X-ray Tube Carriage Assembly Longitudinal Movement Lateral Movement Cable Rail Collimator Click for details OTS Bridge and Rails User Controls Click for details Overhead Tube Suspension (OTS) Rails OTS Bridge and rails: Allows lateral and longitudinal movement of the Tube Suspension. Potentiometers used for positional feedback. X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Image Monitor Image Archive Device (Exabyte Drive) (optional) Control Console for Image Processing System Click for details Digital Image Processing Computer Cabinet Click for details DRS Gateway DRS Gateway The DRS Gateway is an optional hardware solution to provide added network functionality for the DRS. The DRS Gateway is a stand alone PC, running Windows 2000. Its functionality is transparent to the customer and requires no interaction with the customer. Exam Room Monitor Image Processing System X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Hard Disk for Patient Image Storage Digital Image Processing Computer (DRS) Cable Storage Power Supply Digital Image Processing System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Displays number of Images in Current Study and remaining image capacity of hard disks Delete Study: Press twice to delete selected study Delete Image: Press twice to delete current image Brightness and Contrast Adjustment Specialty Keys: Click HERE for details Patient Directory: Select Patient Directory screen on DRS monitor New Patient: Select New Patient screen on DRS monitor Keyboard: used to enter patient information FluoroStore: Saves the current fluoro image to the patient folder Image Processing Console (DRS) X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Left Screen Click for details Fluoro Dose Selection Vertical & Horizontal Image reverse buttons Right Screen Click for details Collimator Controls Fluoro and Record Exposure Switches Table Angulation Knob IDD Console Longitudinal tabletop drive Switch Vertical and Longitudinal Power Assist handle X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Image Head Spot Film Device (SFD) Positioner Cabinet System Cabinet Generator Cabinet Positioner Overhead Tube Suspension Image Processing System Control Area X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Photospot Controller (controls Cut Film Photospot camera) Exposure & System Control (known as Kernel) TV Camera Controller and Video Processor (VIC) System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Interface Bulkhead Table and Spot Film Device Controller Table Angulation Controller Positioner Power Distribution Positioner Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Rotor Controller (TIRC) Generator Control (kV & mA) On/Off Switch High Voltage Transformer Volt Pack (feeds primary voltage to the HV Transformer) LFX Generator Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Generator Control (kV & mA) Rotor Controller (TIRC) Generator Power Distribution On/Off Switch Inverter Modules 1 and 2 Input Auto Transformer High Voltage Transformer MPPU Generator Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Off (disables power to Table, OTS & Wallstand) Bucky Tray Table Controls Click for details Positioner X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Optics and Image Gate Assembly Camera Cut Film Camera (105mm) Image Intensifier Power Supply Image Intensifier Spot Film Console Click for details Cassette Tray Image Head and SFD X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Integrated User Interface (IUI) Touch screen X-ray ON indicator Reset Power On/Off Exposure Switch Selection Wheel Control Console X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Bridge X-ray Tube Carriage Assembly Longitudinal Movement Lateral Movement Cable Rail Collimator Click for details OTS Bridge and Rails User Controls Click for details Overhead Tube Suspension (OTS) Rails OTS Bridge and rails: Allows lateral and longitudinal movement of the Tube Suspension. Potentiometers used for positional feedback. X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Image Monitor Image Archive Device (Exabyte Drive) (optional) Control Console for Image Processing System Click for details DRS Gateway Digital Image Processing Computer Cabinet Click for details DRS Gateway The DRS Gateway is an optional hardware solution to provide added network functionality for the DRS. The DRS Gateway is a stand alone PC, running Windows 2000. Its functionality is transparent to the customer and requires no interaction with the customer. Exam Room Monitor Image Processing System X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Hard Disk for Patient Image Storage Digital Image Processing Computer (DRS) Cable Storage Power Supply Digital Image Processing System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Image Intensifier Field of View selection buttons Bolus Lock Table Bucky select Grid Drive Cone Drive Fluoro Timer Reset Collimator Controls Fluoro and Record Exposure Switches Table Angulation Knob SFD Lock release buttons Film Format Selection buttons SFD Console Photo Spot Camera select Longitudinal & Lateral table-top drive Switch Vertical and Longitudinal Power Assist handle X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Displays number of Images in Current Study and remaining image capacity of hard disks Delete Study: Press twice to delete selected study Delete Image: Press twice to delete current image Brightness and Contrast Adjustment Specialty Keys: Click HERE for details Patient Directory: Select Patient Directory screen on DRS monitor New Patient: Select New Patient screen on DRS monitor Keyboard: used to enter patient information FluoroStore: Saves the current fluoro image to the patient folder Image Processing Console (DRS) X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Rotating Tube Arm Xray Tube Locks release button Collimator On/Off Switch Tube Latch Mechanism & Switch Control Panel Exposure switch Imaging PC Touchscreen Power Cord, On/Off Breaker and Network connection Drive Handle Digital Detector AMX 700 Collision Sensor (blocks forward drive movement when activated) Body of AMX contains Generator, Digital Imaging PC, Drive Batteries, Drive and Charging Electronics and Motors X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Rotating Tube Arm Xray Tube Collimator Tube Latch Mechanism & Switch Lead Apron Hanger On/Off Switch Locks release button Control Panel Exposure switch Power Cord, On/Off Breaker Drive Handle Cassette Storage Drawer AMX 4 Collision Sensor (blocks forward drive movement when activated) Body of AMX contains Generator, Drive Batteries, Drive and Charging Electronics and Motors X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Click on the yellow boxes for more information Table Control Area System Cabinet OTS Wall Stand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Jedi Generator: Generates the power used by the x-ray tube Corona 2 Board controls the system power on, off and reset functions and also serves as a CAN Hub for the system’s CAN buses. Power Distribution Unit (PDU): Distributes 120Vac & 230Vac around the system Bulkhead Halo Board Contains relays which are used to switch power to the system. The relays are controlled by the Corona 2 Board. On/Off Switch System Cabinet X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Control, Patient List & Image Monitor Radiographic Control Interface Module (RCIM) Click for details Exposure Switch CD-RW/DVD ROM Drive Mouse Wall Plate (located under counter) System and Image Processing Computer (aka Magic PC) Keyboard X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Vertical Longitudinal (along overhead rails) Lateral (along overhead rails) Column rotation at the goose neck Xray Tube Angulation Carriage Telescopic Column Vertical Tube Angulation User Interface Console Click for details X-ray Tube Collimator Click for details X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Wallstand Display Operator Handle Wall Stand (Standard version) Collimator Remote Control Extended Arm Version of Wall Stand Detector Angulation and SID Display TRAD Detector used in Wallstand X-ray Photo Tour- Rev.2 by E.Singleton CLOSE Movements Enable Button Lit= movements disabled OFF= movements enabled Floating Table-top Detector Emergency Movements Off Button When pressed disables all room movements Table Up/Down Table Down TRAD Detector used in Table Table Up Table-top Locks Release (longitudinal & lateralfloating table-top mode) X-ray Photo Tour- Rev.2 by E.Singleton CLOSE LEDs Longitudinal Lock Release Ready Exposure Inhibit Manual Collimation SID Detent Lateral Detent Long Detent Lateral Lock Release Tube Angulation Lock Release Interlock Override Switch Horizontal=override position Vertical Lock Release Touch-screen Display Column Rotation Lock Release All Locks Release Indicator Collimator Field Light Detent Lock All Locks Release Button Detent Lock Indicator OTS User Interface Console X-ray Photo Tour- Rev.2 by E.Singleton