Uploaded by Zitouni Hachem

config-T5220

advertisement
Product Name: SPARC-Enterprise-T5220
Part/Serial Number:
Host Power:
602-3824-09 / BEL0830XTR
On
System Status: Normal
SysFW Version: Sun System Firmware 7.4.5 2012/12/11 23:47
SP Hostname: SUNSP0021280FABFF
Uptime:
0 days, 02:55:16
IP Address:
192.168.1.46
ILOM Version: v3.0.12.4.y r77080
System Configuration: Oracle Corporation sun4v SPARC Enterprise T5220
Memory size: 2944 Megabytes
================================ Virtual CPUs ================================
CPU ID Frequency Implementation
Status
------ --------- ---------------------- ------0
1415 MHz SUNW,UltraSPARC-T2
on-line
1
1415 MHz SUNW,UltraSPARC-T2
on-line
2
1415 MHz SUNW,UltraSPARC-T2
on-line
3
1415 MHz SUNW,UltraSPARC-T2
on-line
4
1415 MHz SUNW,UltraSPARC-T2
on-line
5
1415 MHz SUNW,UltraSPARC-T2
on-line
6
1415 MHz SUNW,UltraSPARC-T2
on-line
7
1415 MHz SUNW,UltraSPARC-T2
on-line
======================= Physical Memory Configuration ========================
Segment Table:
-------------------------------------------------------------Base
Segment Interleave Bank
Address
Size
Factor
Size
Contains
Modules
-------------------------------------------------------------0x0
8 GB
4
2 GB
MB/CMP0/BR0/CH0/D0
2 GB
MB/CMP0/BR1/CH0/D0
2 GB
MB/CMP0/BR2/CH0/D0
2 GB
MB/CMP0/BR3/CH0/D0
================================ IO Devices ================================
Slot +
Bus Name +
Status
Type Path
Model
Speed
---------------------------------------------------------------------------MB/NET0
PCIE network-pciex8086,105e
2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0
MB/NET1
PCIE network-pciex8086,105e
2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1
MB/NET2
PCIE network-pciex8086,105e
2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0
MB/NET3
PCIE network-pciex8086,105e
2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1
MB/SASHBA
PCIE scsi-pciex1000,58
LSI,1068E 2.5GTx4
/pci@0/pci@0/pci@2/scsi@0
MB/RISER1/PCIE1 PCIE SUNW,qlc-pciex1077,2532
QLE2562 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0
MB/RISER1/PCIE1 PCIE SUNW,qlc-pciex1077,2532
QLE2562 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0,1
MB
PCIX usb-pciclass,0c0310
--
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0
MB
PCIX usb-pciclass,0c0310
--
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,1
MB
PCIX usb-pciclass,0c0320
--
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2
============================ Environmental Status ============================
Fan sensors:
---------------------------------------------------------------Location
Sensor
Status
---------------------------------------------------------------SYS/FANBD0/FM0/F0
TACH
ok
SYS/FANBD0/FM0/F1
TACH
ok
SYS/FANBD0/FM1/F0
TACH
ok
SYS/FANBD0/FM1/F1
TACH
ok
SYS/FANBD0/FM2/F0
TACH
ok
SYS/FANBD0/FM2/F1
TACH
ok
Fan indicators:
---------------------------------------------------------------Location
Sensor
Condition
---------------------------------------------------------------SYS/PS0
FAN_FAULT
ok
SYS/PS1
FAN_FAULT
ok
Temperature sensors:
---------------------------------------------------------------Location
Sensor
Status
----------------------------------------------------------------
SYS/MB
T_AMB
ok
SYS/MB/CMP0/BR0/CH0/D0
T_AMB
ok
SYS/MB/CMP0/BR1/CH0/D0
T_AMB
ok
SYS/MB/CMP0/BR2/CH0/D0
T_AMB
ok
SYS/MB/CMP0/BR3/CH0/D0
T_AMB
ok
SYS/MB/CMP0
T_TCORE
ok
SYS/MB/CMP0
T_BCORE
ok
Temperature indicators:
---------------------------------------------------------------Location
Indicator
Condition
---------------------------------------------------------------SYS/PS0
TEMP_FAULT
ok
SYS/PS1
TEMP_FAULT
ok
Current sensors:
---------------------------------------------------------------Location
Sensor
Status
---------------------------------------------------------------SYS/PS0
I_IN_MAIN
ok
SYS/PS0
I_IN_LIMIT
ok
SYS/PS0
I_OUT_MAIN
ok
SYS/PS0
I_OUT_LIMIT
ok
SYS/PS1
I_IN_MAIN
ok
SYS/PS1
I_IN_LIMIT
ok
SYS/PS1
I_OUT_MAIN
ok
SYS/PS1
I_OUT_LIMIT
ok
Current indicators:
---------------------------------------------------------------Location
Indicator
Condition
---------------------------------------------------------------SYS/MB
I_USB0
ok
SYS/MB
I_USB1
ok
SYS/PS0
CUR_FAULT
ok
SYS/PS1
CUR_FAULT
ok
Voltage sensors:
---------------------------------------------------------------Location
Sensor
Status
---------------------------------------------------------------SYS/MB
V_VMEML
ok
SYS/MB
V_VMEMR
ok
SYS/MB
V_+3V3_STBY
SYS/MB
V_VCORE
SYS/MB
V_+3V3_MAIN
SYS/MB
V_VDDIO
SYS/MB
V_+12V0_MAIN
SYS/MB
V_VBAT
SYS/PS0
V_IN_MAIN
SYS/PS0
V_OUT_MAIN
SYS/PS1
V_IN_MAIN
SYS/PS1
V_OUT_MAIN
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
Voltage indicators:
---------------------------------------------------------------Location
Indicator
Condition
----------------------------------------------------------------
SYS/MB
VCORE_POK
ok
SYS/MB
VMEML_POK
ok
SYS/MB
VMEMR_POK
ok
SYS/PS0
AC_POK
ok
SYS/PS0
DC_POK
ok
SYS/PS0
VOLT_FAULT
SYS/PS1
AC_POK
ok
SYS/PS1
DC_POK
ok
SYS/PS1
VOLT_FAULT
ok
ok
LEDs:
---------------------------------------------------------------Location
LED
State
---------------------------------------------------------------SYS
SERVICE
off
SYS
LOCATE
off
SYS
ACT
SYS
PS_FAULT
SYS
TEMP_FAULT
SYS
FAN_FAULT
steady
off
off
off
SYS/MB/CMP0/BR0/CH0/D0
SERVICE
off
SYS/MB/CMP0/BR1/CH0/D0
SERVICE
off
SYS/MB/CMP0/BR2/CH0/D0
SERVICE
off
SYS/MB/CMP0/BR3/CH0/D0
SERVICE
off
SYS/HDD0
SERVICE
off
SYS/HDD0
OK2RM
off
SYS/HDD1
SERVICE
off
SYS/HDD1
OK2RM
off
SYS/HDD2
SERVICE
off
SYS/HDD2
OK2RM
off
SYS/HDD3
SERVICE
off
SYS/HDD3
OK2RM
off
SYS/HDD4
SERVICE
off
SYS/HDD4
OK2RM
off
SYS/HDD5
SERVICE
off
SYS/HDD5
OK2RM
off
SYS/HDD6
SERVICE
off
SYS/HDD6
OK2RM
off
SYS/HDD7
SERVICE
off
SYS/HDD7
OK2RM
off
SYS/FANBD0/FM0
SERVICE
off
SYS/FANBD0/FM1
SERVICE
off
SYS/FANBD0/FM2
SERVICE
off
============================ FRU Status ============================
Location
Name
Status
-----------------------------------------------------SYS
MB
enabled
SYS/MB
RISER0 enabled
SYS/MB
RISER1 enabled
SYS/MB
RISER2 enabled
SYS/MB
SCC_NVRAM enabled
SYS/MB/CMP0/BR0/CH0
D0
enabled
SYS/MB/CMP0/BR1/CH0
D0
enabled
SYS/MB/CMP0/BR2/CH0
D0
enabled
SYS/MB/CMP0/BR3/CH0
D0
enabled
SYS
HDD0
enabled
SYS
HDD1
enabled
SYS
HDD2
Not present
SYS
HDD3
Not present
SYS
HDD4
Not present
SYS
HDD5
Not present
SYS
HDD6
Not present
SYS
HDD7
Not present
SYS
PDB
SYS
SASBP
SYS
DVD
SYS
USBBD
SYS
FANBD0 enabled
enabled
enabled
enabled
enabled
SYS/FANBD0
FM0
enabled
SYS/FANBD0
FM1
enabled
SYS/FANBD0
FM2
enabled
SYS
FANBD1 enabled
SYS
PS0
enabled
SYS
PS1
enabled
============================ FW Version ============================
Version
-----------------------------------------------------------Sun System Firmware 7.4.5 2012/12/11 23:47
====================== System PROM revisions =======================
Version
-----------------------------------------------------------OBP 4.33.6.b 2012/12/11 20:50
Chassis Serial Number
--------------------BEL0830XTR
=====================================================================================
=====================================================================================
CPU
psrinfo -pv
The physical processor has 8 virtual processors (0-7)
UltraSPARC-T2 (chipid 0, clock 1415 MHz)
psrinfo -v
Status of virtual processor 0 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:08.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 1 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 2 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 3 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 4 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 5 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 6 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
Status of virtual processor 7 as of: 02/12/2019 11:23:42
on-line since 02/12/2019 10:24:10.
The sparcv9 processor operates at 1415 MHz,
and has a sparcv9 floating point processor.
=====================================================================================
====================================================================================
Fiber Card
/pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0,1
QLogic QLE2562 Host Adapter FCode(SPARC): 2.03 06/30/08
Firmware version 4.03.02
SFP state: 8Gb Present
/pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0
QLogic QLE2562 Host Adapter FCode(SPARC): 2.03 06/30/08
Firmware version 4.03.02
SFP state: 8Gb Present
DISKS
/pci@0/pci@0/pci@2/scsi@0
MPT Version 1.05, Firmware Version 1.22.00.00
Target 0
Unit 0 Disk
SEAGATE ST914602SSUN146G0603 286739329 Blocks, 146 GB
SASAddress 5000c5000ebe209d PhyNum 0
Target 1
Unit 0 Disk
HITACHI H103030SCSUN300GA2A8 585937500 Blocks, 300 GB
SASAddress 5000cca00a92f255 PhyNum 1
Lecteur CD/DVDW
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2
Unit 0 Removable Read Only device TSSTcorpCD/DVDW TS-T632ASR03
Download