E-LINK RP 435 MASTER E - LINK START STOP Pr 1753-27 Operating Manual from year of manufacture 2005 1755.99.03.02 09.05 E-Link for RP 435 MASTER 1 INTRODUCTION.............................................................................................................................5 2 REQUIREMENTS ON THE MACHINE...........................................................................................5 3 SAFETY INSTRUCTIONS ..............................................................................................................6 3.1 3.2 3.3 3.4 3.5 4 THE MENUS ...................................................................................................................................9 4.1 4.2 5 OVERVIEW OF THE KEY FUNCTIONS IN THE "SYSTEMINFO" MENU: ................................................27 "DIAGNOSIS" MENU ...................................................................................................................28 8.1 8.2 8.3 9 OVERVIEW OF THE KEY FUNCTIONS IN THE "SETUP" MENU: .........................................................25 "SYSTEMINFO" MENU ................................................................................................................26 7.1 8 THE DISPLAY ............................................................................................................................11 TYING MODES ...........................................................................................................................12 HYDRAULIC VALVE BLOCK .........................................................................................................13 OPERATING PARAMETERS .........................................................................................................16 MACHINE STATUS: BALING ........................................................................................................20 MACHINE STATUS: TYING ..........................................................................................................20 MACHINE STATUS: OPEN TAIL GATE ...........................................................................................20 MACHINE STATUS: TAIL GATE OPENED .......................................................................................21 MACHINE STATUS: CLOSE TAIL GATE .........................................................................................21 OVERVIEW OF THE KEY FUNCTIONS IN THE "MONITOR" MENU“ .....................................................22 "SETUP" MENU ...........................................................................................................................23 6.1 7 OVERVIEW .................................................................................................................................9 SELECT A MENU..........................................................................................................................9 "MONITOR" MENU ......................................................................................................................10 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 6 WARNING SYMBOLS ....................................................................................................................6 GENERAL INFORMATION ..............................................................................................................7 INSTRUCTIONS FOR FIRE PROTECTION .........................................................................................7 PROTECTION OF THE ELECTRONIC CONTROL SYSTEM ...................................................................8 ELECTROMAGNETIC COMPATIBILITY (EMC)..................................................................................8 STANDARD DIAGNOSIS ..............................................................................................................29 EXTENDED DIAGNOSIS ..............................................................................................................35 OVERVIEW OF THE KEY FUNCTIONS IN THE "DIAGNOSIS" MENU:...................................................37 "STATISTICS" MENU ..................................................................................................................38 9.1 OVERVIEW OF THE KEY FUNCTIONS IN THE "STATISTICS" MENU: ..................................................39 WELGER RP 435 MASTER E-LINK 3 10 ERROR MESSAGES ................................................................................................................40 10.1 10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 10.10 10.11 11 11.1 11.2 11.3 11.4 11.5 11.6 12 12.1 12.2 12.3 12.4 13 13.1 SYSTEM ERROR MESSAGES .......................................................................................................41 SYSTEM ERROR: "SHORT CIRCUIT IN SUPPLY OF SENSORS" ........................................................41 SYSTEM ERROR: "BATTERY VOLTAGE TOO HIGH"........................................................................41 STANDARD ERROR MESSAGES ...................................................................................................43 ERROR MESSAGE: "OVERLOAD" ................................................................................................43 ERROR MESSAGE: "WIRE BROKEN" ...........................................................................................43 ERROR MESSAGE: "SET NET KNIFE !" .........................................................................................44 ERROR MESSAGE: "NET KNIFE SET ?"........................................................................................44 ERROR MESSAGE: "1 TAILGATE HOOK OPEN" .............................................................................44 ERROR MESSAGE: "NO PRESSURE INCREASE !"..........................................................................45 ERROR MESSAGE: "HYD DEN EXEEDED !" ...................................................................................45 "SYSTEM SERVICE" MENU ....................................................................................................46 CALL-UP „SYSTEM SERVICE“ MENU ...........................................................................................46 "MONITOR" SUBMENU ...............................................................................................................47 "SYSTEM SETUP" SUBMENU ......................................................................................................47 "EEPROM CONTENTS" SUBMENU ............................................................................................48 "SELF TEST" SUBMENU .............................................................................................................48 OVERVIEW OF THE BUTTON FUNCTIONS IN THE "SYSTEM SERVICE" MENU:...................................49 OSCILLOSCOPE ......................................................................................................................50 OSCILLOSCOPE FOR DIGITAL SENSORS AND ACTORS ..................................................................51 OSCILLOSCOPE FOR DISTANCE SENSORS ...................................................................................52 OPERATING THE OSCILLOSCOPE ................................................................................................53 OVERVIEW OF THE BUTTON FUNCTIONS IN THE "OSCILLOSCOPE":................................................56 APPENDIX ................................................................................................................................57 CHRONOLOGICAL TYING PROCESS AT AUTOMATIC TYING .............................................................57 Maschinenfabrik GmbH Gebrüder-Welger-Straße 3 • D-38304 Wolfenbüttel Phone: (+49) 53 31 / 404-142 • Fax: (+49) 53 31 / 404-143 eMail: wmf@welger.com 4 WELGER RP 435 MASTER E-LINK 1 Introduction The control contains (see figures bellow): • the control box E-LINK (hand set) • the control unit Balercontrol III The control box E-LINK serves for operating the machine. The control unit Balercontrol III is directly attached to the machine in a solid housing. The control unit and the control box, as well as the respective software contained therein, are provided with their own serial numbers. Always state the serial numbers for possible requests. Please enter this numbers here immediately after delivery: Part Serial number SW rev. ........................... dd ........................... Serial no. ........................... SW version ........................... SW date ........................... Memory ........................... How to find the serial number Keep any key on the control box pressed when connecting the power supply. Control box Control unit Call menu overview. Select SYSTEMINFO menu. Acknowledge selection. 2 Requirements on the machine • On-board power supply ....................12 V • Fuse protection, machine:.................20 A Operation with 24 V power supply is not permissible. WELGER RP 435 MASTER E-LINK 5 3 Safety instructions 3.1 Warning symbols Attention! This symbol stands next to warnings: danger to life, danger of injury, possible serious material damage. Caution! This symbol stands next to safety instructions: malfunctions and impairments of correct operation, possible material damage. Note! This symbol stands next to useful information: special information on how to use the machine most efficiently. 6 WELGER RP 435 MASTER E-LINK 3.2 General Information Attention! Read and heed the operating instruction and safety instructions prior to commission the machine. In this operating instruction all positions required for safety reasons are marked with a warning sign. Instruct all other operators in safety instructions! The warning- and information signs located at the machine give information for safe operation. Watch them for safety reasons! • It is not permissible to enter the working range of the machine or to approach the working range of the machine as long as the electronics are supplied with power. • Prior to any kind of assembly, adjustment and maintenance work, the control must be disconnected from power supply: interrupt electrical connection between tractor and machine. Moreover : Switch off power take-off shaft. Switch off tractor engine and remove ignition key. Uncouple power take-off shaft of the machine from the drive shaft of the tractor. • Check correct setting of all sensors regularly and check that all sensors (proximity switches) and actors (plugs on hydraulic system, plugs on net tying unit or plugs on twine tying unit) are tightened properly. • Power supply of the electronics must only be switched on when the machine is to be operated. After the end of work, the control system must immediately be disconnected from power supply: interrupt electrical connection between tractor and machine. • The housing of the control box is moisture-repellent. Nevertheless: in order to avoid malfunctions, the control box must not be exposed to excessive moisture (e.g. heavy rain, splashing, steam-jet- or high-pressure cleaning machine). • Software- or hardware malfunction can never be totally excluded. Therefore the machine has always to be handled so that no personal or material damages occur. • Read the pertinent documentation before commissioning the machine. In case of difficulties in understanding please contact the customer service department. 3.3 Instructions for fire protection • In certain conditions the harvested crop is easily inflammable. • Keep baler always free from crop remains or oil pollution. This note counts especially after finishing baling. • The present wiring of the control and of the corresponding machine must not be used for electrical consumers other than mounted or proofed by the manufacturer. Overloading the electrical lines leads to excessive heating. • Always keep a working fire extinguisher within reach. WELGER RP 435 MASTER E-LINK 7 3.4 Protection of the electronic control system • All assembly work (connection and disconnection of sensors, valves, control box etc., replacement of fuses) must be carried out with the power supply switched off. • The control is designed for 12 Volt operation. Operation with other on-board power supplies is not permissible! • The correct polarity of the power supply of the tractor must not be changed, otherwise the electronic control could be damaged. • In case of welding work on the baler: - Do not permit welding current to flow through the control unit; - Interrupt power supply between tractor and baler; - Take heat generation at the welding points into account; if necessary remove sensitive parts (cables, sensors or the like) prior to welding. 3.5 Electromagnetic compatibility (EMC) The machine is equipped with electronic components and modules; the function of these electronic components and modules can be influenced by electromagnetic emissions of other equipment. Such influences can cause risks to persons, if the following safety instructions are not observed: In case of subsequent installation of electrical and electronic equipment and/or components into the machine, with connection to the central mains, it is the user's responsibility to check whether the installation impairs the vehicle electronics or any other components. Ensure above all that the electrical and electronic components subsequently installed are in conformity with the EMC directive 89/336/EEC as amended, and that they are provided with the CE. 8 WELGER RP 435 MASTER E-LINK 4 The menus 4.1 Overview Menu Task see chapter MONITOR Display and operation in daily machine operation "Monitor" menu page 10 SETUP Setting of machine parameters "Setup" menu page 23 SYSTEMINFO Information about selected system data "Systeminfo" menu page 26 DIAGNOSIS Diagnostic functions for checking the machine "Diagnosis" menu page 28 STATISTICS Machine running time, cumulative counter and daily counter "Statistics" menu page 38 4.2 Select a menu Open menu overview : press key Select menu: keys . or Confirm selection with key . If no menu is to be selected: if no key is pressed for 5 seconds, automatic return to the MONITOR menu is effected. WELGER RP 435 MASTER E-LINK 9 5 "Monitor" menu The MONITOR menu is the standard menu. This menu is used for daily machine operation. The MONITOR menu appears automatically as soon as the control is supplied with power. Open menu overview: press key Select MONITOR menu: keys or Confirm selection with key The following information are displayed in the menu MONITOR: Central main field • Machine status (baling, tying, ...) • Bar graph for present and preselected bale diameter • Soft-center mode • Knife in cutting position Beside the main field • Day counter • Machine working time • Battery voltage • PTO speed Below the main field • Tying mode • Hydraulic valve block (Cutting device, Bottom door, Pick-Up) • Operating parameter (Bale diameter, Net layers) 10 WELGER RP 435 MASTER E-LINK 5.1 The display Tying mode Hydraulic switch Operating parameter (see page 12) (see page 13) (see page 16) manual twine tying moving the pick-up bale diameter automatic twine tying moving the bottom door density (pressure) manual net tying moving the cutting device (here: 12 knives selected) net layers (here: set value 1.5) automatic net tying WELGER RP 435 MASTER E-LINK 11 5.2 Tying modes The machine can be equipped with: • Net tying • Twine tying The tying modes shown in the following table result from the setup setting (see chapter 6 "Setup" menu): Tying mode Machine with twine tying manual twine tying • automatic twine tying • Machine with net tying manual net tying • automatic net tying • The tying modes can be selected with the left key. Start tying: Press key <START/STOP> 12 . WELGER RP 435 MASTER E-LINK 5.3 Hydraulic valve block The unit* that is to be moved hydraulically can be selected with the hydraulic switch. * The machine can – according to the type of the machine – be equipped with the following units: • Pick-up (see chapter 5.3.1 Hydraulic switch: Pick-Up) • Bottom door (see chapter 5.3.2 Hydraulic switch: bottom door) • Cutting device (see chapter 5.3.3 Hydraulic switch: Cutting device) The units are selected with the centre key. The selected unit is displayed directly above the centre key: Unit Symbol Pick-Up bottom door Cutting device The selected unit is moved by means of the tractor's distribution valve. WELGER RP 435 MASTER E-LINK 13 5.3.1 Hydraulic switch: Pick-Up Press centre key to select the pick-up The Pick-Up is displayed directly above the centre key: Move Pick-Up with the tractor's distribution valve. Note! The valves of the hydraulic switch are not actuated in Pick-Up position This setting has to be preferred to minimise the power consumption. 5.3.2 Hydraulic switch: bottom door Press centre key to select the bottom door The bottom door is displayed directly above the centre key: Move bottom door with the tractor's distribution valve. When the bottom door is opened because of a material jam this condition is displayed in a window (symbol "Bottom door"; with flashing exclamation mark). 14 WELGER RP 435 MASTER E-LINK 5.3.3 Hydraulic switch: Cutting device Press centre key to select the cutting device The cutting device is displayed directly above the centre key: Move cutting device with the tractor's distribution valve. The machine can be equipped with a group cutting device of 17 knives or of 25 knives. The setting is made in Setup (see chapter 6 "Setup" menu / see separate users manual "RP 405 / RP 435"). • The 17-knife cutting device is divided into 2 groups: A 8-knife group and a 9-knife group. • The 25-knife cutting device is divided into 2 groups: A 12-knife group and a 13-knife group. It can be operated with one knife group or both knife groups at the same time. The knife group being in cutting position is displayed (here: 12-knife group). Caution! Before a knife group can be moved into operating position all knives that are possibly already in operating position, must be moved out of the operating position. If it must be operated with an other knife group, first the knife group being in operating position must be moved into home position before the new knife group can be moved from its home position into operating position. Only those knife groups are displayed that can be moved in or out for the current moment, e.g. (here: 12-knife group). WELGER RP 435 MASTER E-LINK 15 5.4 Operating parameters The operating parameters are selected with the right key. The operating parameter selected is displayed directly above the key. 5.4.1 Operating parameters: Set / read bale diameter Set bale diameter: after selection of the operating parameter "Bale diameter" the value can be set in 1-digit increments using the keys / . The following overview shows the possible numerical values for the bale diameter display: Minimum bale diameter *90 *91 Maximum bale diameter *92 ... *98 *99 00 01 02 ... 58 59 60 Read bale diameter: the bale diameter currently reached can be read on the indicating instrument on the machine (see left figure) or on the display of the control box (see right figure). 16 WELGER RP 435 MASTER E-LINK 5.4.2 Operating parameters: Set / read baling density Set baling density (= bale density, = pressure): after selection of the operating parameter "Baling / density" the value can be set in 1-digit increments using the keys . The following overview shows the possible numerical values for the baling density: Minimum baling density 0 1 Maximum baling density 2 3 4 5 6 7 8 9 10 When the baling density reaches stage 10 in a manual tying mode, the message "Stop: Max. baling density reached" is output (see chapter 10 Error messages). Read baling density (pressure): the baling density currently reached can be read on the pressure gauge on the machine (see figure). WELGER RP 435 MASTER E-LINK 17 Emergency operation: Set baling density If one of the following error messages appears ERROR! PRESSURE SENSOR WIRE BROKEN or ERROR! NO PRESSURE INCREASE but the pressure gauge on the machine still indicates a pressure (baling density), a defective pressure sensor may be the cause of the fault. Nevertheless the baling density can be set in the mergency operating mode described below: Set baling density to "0" : press key . Press key and key simultaneously. Now an "X" appears in the display (in the place where usually the baling density is displayed), see figure. To set the baling density: (Valve on machine tail) Turn the handwheel attached laterally to the machine clockwise up to the stop. In this position the maximum pressure (maximum baling density) is set. If a lower baling density is desired you can turn the handwheel back in counterclockwise direction. 18 WELGER RP 435 MASTER E-LINK 5.4.3 Operating parameters: Set net layers Net layers can only be set on the control box, when electronic net control has been selected in the "Setup" menu (see chapter 6 "Setup" menu, page 23): EL.NET-CTRL. = YES Set net layers: After selection of the operating parameter "Net layers" the value can be set in increments of 0.5 using the keys / . The following overview shows the possible numerical values for the net layers: Few net layers 0.5 Many net layers 1 1.5 2 2.5 3 3.5 4 4.5 5 After the net length (required for the set number of net layers) has passed the machine, the net knife is automatically activated and tying is finished. WELGER RP 435 MASTER E-LINK 19 5.5 Machine status: Baling The machine status baling is displayed by an animated material flow into the baler, when the PTO speed is larger than 100 rpm (revolutions per minute). 5.6 Machine status: Tying Two rotating arrows indicate that tying is being carried out. 5.7 Machine status: Open tail gate After tying has been finished, the electronics indicate with a flashing arrow and a beep to open the tail gate. No material flows any more into baler. 20 WELGER RP 435 MASTER E-LINK 5.8 Machine status: Tail gate opened The open tail gate is displayed in the main window. There is no material flow. 5.9 Machine status: Close tail gate After the bale has left the baler, the electronics indicate with a flashing arrow to close the tail gate. No material flows into baler. WELGER RP 435 MASTER E-LINK 21 5.10 Overview of the key functions in the "Monitor" menu“ Key Operation Select tying mode (see chapter 5.2 Tying modes): left key • • • • manual twine tying automatic twine tying manual net tying automatic net tying Select hydraulic switch (see chapter 5.3 Hydraulic valve block): centre key • • • • • Pick-Up bottom door cutting device 8 knives cutting device 9 knives cutting device 17 knives (optional: 12 knives) (optional: 13 knives) (optional: 25 knives) Select operating parameter (see chapter 5.4 Operating parameters): right key • • • Bale density Baling density (pressure) Net layers Start selected tying mode manually Increase set value for selected operating parameters • • • Bale density Baling density (pressure) Net layers Decrease set value for selected operating parameters • • • Bale density Baling density (pressure) Net layers – no function – Acknowledge fault message (delete) (see chapter 10 Error messages) Call up menu 22 WELGER RP 435 MASTER E-LINK 6 "Setup" menu The SETUP menu serves for setting various machine parameters (Language, Machine type, Beep ...). Open menu overview: press key Select Setup menu: keys or Confirm selection with key Select parameter: keys and Change parameter: keys and Either return to menu overview: press key Or return to 3 sec. MONITOR menu: press key for Scroll the display pages forward and backward: left and right key. WELGER RP 435 MASTER E-LINK 23 The following machine parameters can be set: Machine parameter Setting range Language English– German – French – Swedish – Norwegian – Finnish – Spanish – Italian – Danish – Dutch Machine type RP435 RP435S (with cutting device) Delay 0 sec. / 2,5 sec. / 5,0 sec. (Delay of the buzzer while twine tying or net insertion while net tying during the tying process, see chapter 13 Appendix) yes / no Soft center „yes“ means: The bale is to be produced with a softer center. Therefore the preset pressure in the baling chamber does not build up completely (up to the user entered value) before the bale diameter has reached 75 % of the preset value. Net tying yes / no (setting according to machine's equipment) Twine tying yes / no (setting according to machine's equipment) Electronic net control yes / no (= electronic monitoring of the set number of net layers) "yes" means: • input of the desired number of net layers via ELINK control box (see chapter "5.4.3 Operating parameters: “Set net layers", page 19). • electronic control / monitoring of the set number of net layers by the control system. "no" means: • emergency function only! Input of the desired number of net layers by means of the wing nut in the slotted hole of the net tying unit (see chapter "Emergency operation: Net tying" in the separate manual "RP 405/435"). 13, 17 or 25 Knives (only for machine type RP435S) Beep 24 0 ... 50 WELGER RP 435 MASTER E-LINK 6.1 Overview of the key functions in the "Setup" menu: Key Operation Scroll display pages backwards left key – no function – centre key Scroll display pages forward right key – no function – Change parameter Change parameter Select parameter Select parameter Open menu overview: short key stroke Return to MONITOR menu: 3 sec. key stroke WELGER RP 435 MASTER E-LINK 25 7 "Systeminfo" menu Open menu overview: press key Select SYSTEMINFO menu: key Confirm selection with key menu provides important system data: Serial number Software version Software date Memory SYSTEMINFO . or . information about The menu SYSTEMINFO is exclusively for information. Data can neither be entered nor selected in the menu SYSTEMINFO. Either return to menu overview: press key Or return to 3 sec. 26 MONITOR menu: press key for WELGER RP 435 MASTER E-LINK 7.1 Overview of the key functions in the "Systeminfo" menu: Key Operation – no function – left key – no function – centre key – no function – right key – no function – – no function – – no function – – no function – – no function – Open menu overview: short key stroke Return to MONITOR menu: 3 sec. key stroke WELGER RP 435 MASTER E-LINK 27 8 "Diagnosis" menu The control contains extensive diagnostic routines for checking the function the electric equipment. There are two diagnostic routines: Standard diagnosis (see chapter 8.1 Standard diagnosis) Standard diagnosis may only be performed after the machine has been stopped. In addition, a fully automatic actor test is possible. Extended diagnosis (see chapter 8.2 Extended diagnosis) Diagnostic functions while machine is in operation. Observation of all sensor channels and actor channels possible. Selection via special key combination. Attention, danger of injury! Extended diagnosis is executed while the machine is running. For trained and instructed service personnel only! 28 WELGER RP 435 MASTER E-LINK 8.1 Standard diagnosis Attention, danger of injury! Standard diagnosis may only be performed after the machine has been stopped: Switch off tractor engine, wait until machine has stopped, disconnect hydraulic supply to the machine. Open menu overview : press key Select DIAGNOSIS menu: keys or Confirm selection with key To previous display page: left key To next display page: right key Either return to menu overview: press key Or return to 3 sec. 8.1.1 MONITOR menu: press key for Standard diagnosis – Digital sensors Digital sensors are e.g. proximity sensors and switches. In the DIGITAL SENSORS DIAGNOSIS, the status of proximity sensors and switches is displayed. Note! The number of the sensors shown or of the display pages depends on the settings in the "Setup" menu (see chapter 6 "Setup" menu). The following symbols are used for the sensor status: Sensor type Proximity sensors Symbol Status covered („sees“ metal) uncovered („sees no metal“) Switch opened closed WELGER RP 435 MASTER E-LINK 29 Net tying On the page DIAGNOSIS DIGITAL following sensors are displayed: SENSORS 1/2 the Diagnosis Digital Sensors 1/2 Twine tying Net tying Abbreviation Name Sensor checks RPM revolutions per minute revolutions of p.t.o DIAMETER max. bale diameter position of the tailgate wing PRESS.SW locking of the cutting device pressure in the cutting device hydraulics CUTT.DEV.1 knife group 1 (smaller group) knives in cutting position? BOTTOM bottom (bottom door) open / closed? NETKNIFE net knife (only for net tying) home position / cutting position? NET RUN net run (only for net tying) revolutions of the net infeed roll (determination of the net length) CUTT.DEV.1 knife group 1 (smaller group) knives in cutting position? On the page DIAGNOSIS DIGITAL following sensors are displayed: SENSORS 2/2 the Diagnosis Digital Sensors 2/2 Twine tying Abbreviation Name Sensor checks HOOK L. Locking device, left open / closed? HOOK R. Locking device, right open / closed? EJECTOR Bale kicker up / down TWINE L. Left twine Twine run left (only twine tying) TWINE R. Right twine Twine run right (only twine tying) In the E-LINK system, an oscilloscope is available in addition to the various diagnostic functions (see chapter 12 Oscilloscope). The oscilloscope can be used to view and analyse the status of all digital sensors and actors during the last 500 seconds. Viewing of all signals in real time is also possible: To the oscilloscope: press centre key 30 WELGER RP 435 MASTER E-LINK 8.1.2 Standard diagnosis – Analog sensors In DIAGNOSIS ANALOG SENSORS the state of the analog sensors is displayed. On the page DIAGNOSIS ANALOG following sensors are displayed: SENSORS 1/2 the Diagnosis Analog Sensors ½ Abbreviation Meaning DIAMETER Voltage value [Volt] shows the position of the tailgate wing (corresponds to the present bale diameter). RP 435: 0,5 Volt (with empty bale chamber) RP 535: 0,45 Volt (with empty bale chamber) On the page DIAGNOSIS ANALOG following sensors are displayed: SENSORS 2/2 the Diagnosis Analog Sensors 2/2 WELGER RP 435 MASTER E-LINK Abbreviation Meaning PRESSURE Measured value [per cent] indicates the pressure in the hydraulic bale density control system (corresponds to the current bale density). CALIBRATING Measured value [per cent] indicates the hydraulic zero point of the pressure sensor. PRESSURE SENSOR TYPE Indicates the recognised pressure sensor type: Type 1 / Type 2 31 8.1.3 Standard diagnosis – Actors Actors are e.g. electro-valves of the hydraulic system. In the ACTOR DIAGNOSIS, the status of the actor channels is displayed. The functions can be tested manually (Diagnosis Manual) or automatically (Diagnosis Automatic). Attention, danger of injury! Standard diagnosis may only be performed after the machine has been stopped: Switch off tractor engine, wait until machine has stopped, disconnect hydraulic supply to the machine. Note! The number of the actors shown or of the display pages depends on the settings in the "Setup" menu (see chapter 6 "Setup" menu). See following chapters: "Standard diagnosis – Actors – Manual" page 33" "Standard diagnosis – Actors – Automatic" page 34 32 WELGER RP 435 MASTER E-LINK Standard diagnosis – Actors – Manual To toggle between DIAGNOSIS ACTORS MANUAL DIAGNOSIS ACTORS AUTOMATIC: Press key and <START/STOP>. Select actor channel: keys and Switch actor on: key Switch actor off: key The following symbols are used for the actor status: Symbol Actor status Actor has been triggered (+) and has switched (+). Actor should be triggered (+), but has not switched (–). Attention, fault! e. g. actor channel in control unit defective. Actor not triggered (–), but has switched (+). Attention, fault! e. g. short circuit or broken wire. Actor has not been triggered (–) and has not switched (–). Net tying On the page DIAGNOSIS ACTORS following actors are displayed: MANUAL 1/1 the Diagnosis Actors Manual 1/1 Twine tying Abbreviation Channel designation VAL.B1 Valve B1* VAL.B2 Valve B2* VAL.B3 Valve B3* VALB45 Valve B45* PVALVE Control valve of hydraulic bale density control system NET CLUT Magnetic clutch of the net tying unit NET KNIFE net knife tripping device TWI MOT Motor twine insertion * these names are on the plugs or on the hydraulic block (according to the version of the machine) Or return to 3 sec. WELGER RP 435 MASTER E-LINK MONITOR menu: press key for 33 Standard diagnosis – Actors – Automatic To toggle between DIAGNOSIS ACTORS MANUAL DIAGNOSIS ACTORS AUTOMATIC: Press key and <START/STOP>. In the DIAGNOSIS ACTORS AUTOMATIC, all actors are automatically triggered and tested in succession. The following symbols are used for the actor status: Symbol Actor status Actor channel is OK. Actor channel is faulty. Net tying On the page DIAGNOSIS ACTORS the following actors are displayed: AUTOMATIC 1/1 Diagnosis Actors Automatic 1/1 Twine tying Abbreviation Channel designation VAL.B1 Valve B1* VAL.B2 Valve B2* VAL.B3 Valve B3* VALB45 Valve B45* PVALVE Control valve of hydraulic bale density control system NET CLUT Magnetic clutch of the net tying unit NET KNIFE net knife tripping device TWI MOT Motor twine insertion * these names are on the plugs or on the hydraulic block (according to the version of the machine) In the E-LINK system, an oscilloscope is available in addition to the various diagnostic functions (see chapter 12 Oscilloscope). The oscilloscope mode can be used to view and analyse the status of all digital sensors and actors during the last 500 seconds. Viewing of all signals in real time is also possible: To the oscilloscope: press centre key Or return to 3 sec. 34 MONITOR menu: press key . for WELGER RP 435 MASTER E-LINK 8.2 Extended diagnosis Attention, danger of injury! Extended diagnosis is executed while the machine is running. For trained and instructed service personnel only! Net tying Twine tying The extended diagnosis offers a possibility of viewing the state of sensor and actors during machine operation. Operation of the extended diagnosis is identical to that of the standard diagnosis (see chapter „8.1 Standard diagnosis). In case of extended diagnosis, however, the service personnel has exclusively the function of an observer. Any interference in the sequence of machine operations (e.g. starting of the automatic actor diagnosis or switching of a selected actor channel) will immediately stop machine operation and thus the extended diagnosis. Indication for extended diagnosis: the symbol (AUTOMATIC) flashes. Net tying Twine tying WELGER RP 435 MASTER E-LINK 35 Attention, danger of injury! While the machine is in operation: Never climb the machine. Keep sufficient distance to the range of action of the machine: Pick-up, tail gate. Never stay or work below the machine. Never carry out any adjustment and maintenance work on the machine while the drive is running. Before opening the protections: Switch-off tractor's engine, wait for stand still of the machine, take-out ignition key of the tractor, interrupt hydraulic supply to the machine. Open menu overview: press key Call extended diagnosis: Press centre key and key simultaneously. Either return to menu selection: press key Or return to 3 sec. 36 MONITOR menu: press key for WELGER RP 435 MASTER E-LINK 8.3 Overview of the key functions in the "Diagnosis" menu: Key Operation Page backwards left key Call up oscilloscope centre key Page forwards right key Toggling between automatic and manual actor diagnosis: Actor channel On Actor channel Off Select actor Select actor Open menu overview: short key stroke Return to MONITOR menu: 3 sec. key stroke WELGER RP 435 MASTER E-LINK 37 9 "Statistics" menu Open menu overview : press key Select STATISTICS menu: keys or Confirm selection with key The STATISTICS menu provides an overview of Bale number (daily counter) Bale number (total) Machine running time (daily counter) Machine running time (total) The "total" counters for bale number (example: 42) and machine running time (example: 44.1 h) are cumulative counters and cannot be erased. 20 daily counters are supported (#1, #2, #3 ... #20). The daily counter selected in each case is used for counting. Select daily counter (view and activate): press key or Erase selected daily counter: press keys and simultaneously for 3 seconds. Symbol Total Meaning Bale number (total) Bale number (daily counter) #3 Total (here e.g. daily counter number 2) Machine running time (total) Machine running time (daily counter) #3 (here e.g. daily counter number 2) Either return to menu selection: press key Or return to sec. 38 MONITOR menu: press key for 3 WELGER RP 435 MASTER E-LINK 9.1 Overview of the key functions in the "Statistics" menu: Key Operation – no function – left key – no function – centre key – no function – right key – no function – + Erase selected daily counter: 3 sec. key stroke Select daily counter (#1, #2, #3, ... #20) Select daily counter (#1, #2, #3, ... #20) Open menu overview: short key stroke Return to MONITOR menu: 3 sec. key stroke WELGER RP 435 MASTER E-LINK 39 10 Error messages Error messages are displayed in a separate window above the current screen. Error messages consist of: • the word ERROR • the error message (text) • a flashing warning triangle • the number of errors which occurred (below the flashing warning triangle) For example: If several errors occur at the same time, the error message of the highest priority is displayed first. A distinction is made between: • System error messages (see from chapter 10.1 System error messages) • Standard error messages (see from chapter 10.4 Standard error messages) Note! If possible errors cannot be removed: Inform the customer service department. Tell the customer service about the displayed error messages. The error messages contain important information about the causes of a possible malfunction to the customer service. 40 WELGER RP 435 MASTER E-LINK 10.1 System error messages System error messages appear in all menus. Exception: standard diagnosis (where no machine functions are in operation). System error messages cannot be acknowledged by pressing a key. They disappear when the cause of the error has been eliminated. 10.2 System error: "Short circuit in supply of sensors" While problems during the sensor's power supply (e.g. during a short circuit in the sensor's power supply or during bad main power supply) the sensor and actor supply of the control unit is switched of automatically, an error window is displayed and an alarm tone sound from the control box. This error cannot be acknowledged. It disappears when the error cause (short circuit or bad main power supply) has been removed. Interrupt power supply immediately: pull plug (DIN 9680B) If the error occurs again after reconnection of the power supply, baling can be processed with switched off electronics and by means of emergency tying (see users manual of the machine, chapter "Emergency operation"). Inform customer service! Use the delivered cable (part no. 0972.20.40.00) to avoid a bad main power supply. 10.3 System error: "Battery voltage too high" In case of excess voltage in the onboard power supply (battery voltage > 17 Volt), the sensor and actor supply of the control unit is switched off, an error window is opened and a permanent warning signal sounds in the control box. This error cannot be acknowledged. The error message disappears when the cause of the error has been eliminated. Inform customer service! Twine tying Interrupt power supply between tractor and machine immediately: Pull out plug [1]. If the error occurs again after reconnection of the power supply baling can be processed with emergency tying: Disconnect control unit: pull both 35-pin plugs [3]. Disconnect control box: pull 7-pin plug [2]. Connect power supply: Insert plug [1] into the socket at the tractor. See users manual of the machine, chapter "Emergency operation of the tying": The red attachment plug for the twine tying is simply plugged into the empty white socket. To trigger the twine tying switch on the parking light (or the low beam or the high beam) for a short time until the twine is grasped by the bale. WELGER RP 435 MASTER E-LINK 41 Net tying Interrupt power supply between tractor and machine immediately: Pull out plug [1]. If the error occurs again after reconnection of the power supply baling can be processed with emergency tying: Interrupt power supply: Pull plug [1] out of the socket at the tractor. See operating manual of the machine, chapter "Emergency operation": The black attachment plug of the electric net coupling is simply plugged into the empty white socket. See operating manual manual of the machine, chapter "Emergency operation": Make additional mechanical adjustments. To trigger the net tying switch on the parking light (or the low beam or the high beam) for a short time until the net is grasped by the bale (recognisable from the fast rotation of the net roll). 42 WELGER RP 435 MASTER E-LINK 10.4 Standard error messages Standard error messages can appear in all menus. Exception: DIAGNOSIS menu. The standard error messages OVERLOAD and WIRE BROKEN are not displayed there. Reaction to standard error messages: Option 1: press key to acknowledge the standard error message. Subsequently, the cause of the fault must be eliminated. Option 2: The standard error message disappears automatically when the cause of the error has been eliminated. 10.5 Error message: "Overload" An error has occurred which has caused overload of an output channel. The output has been switched off. The error message can be acknowledged, the output remains, however, blocked until restart of the system (pull the power supply plug). Acknowledge fault messages: press key 10.6 Error message: "Wire broken" A broken wire or a non-connected load has been recognized. The error message can be acknowledged or disappears automatically when the load is connected again. Acknowledge fault messages: press key WELGER RP 435 MASTER E-LINK 43 10.7 Error message: "Set net knife !" Automatic net wrapping should have been started, but the net knife sensor is not damped. After removal of the error message, net wrapping can be started manually (net knife sensor is ignored). Acknowledge fault messages: press key Start manual net tying (see operating manual of the machine, chapter "Operation / Tying"). 10.8 Error message: "Net knife set ?" Manual net wrapping should have been started, but the net knife sensor is not damped. After removal of the error message, net wrapping can be started manually (net knife sensor is ignored). Acknowledge fault messages: press key 10.9 Error message: "1 tailgate hook open" A locking hook is open. The error message can be acknowledged or disappears automatically when both locking hooks are open or both locking hooks are closed. Acknowledge fault messages: press key 44 WELGER RP 435 MASTER E-LINK 10.10 Error message: "No pressure increase !" No pressure is built up in the hydraulic tensioning system during baling. The error message can be acknowledged. Acknowledge fault messages: press key 10.11 Error message: "hyd den exeeded !" After opening of the tail gate, hydraulic pressure is not released. The error message can be acknowledged. Acknowledge fault messages: press key WELGER RP 435 MASTER E-LINK 45 11 "System Service" menu Attention! The following chapter is intended exclusively for trained and instructed service personnel! The SYSTEM SERVICE menu provides the following submenus for first commissioning and servicing of the machine: Submenu Task see chapter MONITOR Terminates SYSTEM SERVICE menu and starts MONITOR menu. "Monitor" submenu“ page 47 SYSTEM SETUP Machine model toggling, if several user interfaces are available. "System Setup" submenu" page 47 EEPROM CONTENT Display of the EEPROM contents. "EEPROM Contents" submenu" page 48 SELF-TEST Self test of the control (in connection with a special testing device). "Self Test" submenu" page 48 11.1 Call-up „System Service“ menu Call up SYSTEM SERVICE: hold centre button depressed (for about 10 seconds) when switching on the control voltage. Select submenu: keys or Call-up selected submenu: Button 46 WELGER RP 435 MASTER E-LINK 11.2 "Monitor" submenu This menu entry terminates SYSTEM SERVICE and causes return to the Monitor menu, see chapter 5 "Monitor" menu, page 10. 11.3 Select MONITOR menu: keys or Confirm selection with button . "System Setup" submenu The control can be used on other prepared machine families. Select SYSTEM SETUP menu: keys or Confirm selection with key Select machine family: keys or Call up selected machine family: Button Now, the control jumps automatically back to the menu (see chapter 6 "Setup" menu). To safe the changed setting: SETUP Save selection with button WELGER RP 435 MASTER E-LINK 47 11.4 "EEPROM Contents" submenu In this submenu the contents of the EEPROM is shown in hexadecimal form (for diagnostic purposes). Select EEPROM CONTENTS menu: keys or Confirm selection with key Line scrolling: keys 11.5 or Page scrolling: press key or Return to SYSTEM button SERVICE: "Self Test" submenu A fully automatic self-test can be carried out only in connection with special test equipment designed for this purpose. The self-test cannot be started without this test equipment, and is not described here. Select SELF-TEST menu: keys or Confirm selection with button Return to SYSTEM SERVICE: press key 48 WELGER RP 435 MASTER E-LINK 11.6 Overview of the button functions in the "System Service" menu: Key Operation System Service System Setup EEPROM contents Select machine family Scroll up by one line Select machine family Scroll down by one line Self test left button centre button right button Select submenu Scroll down by one page (8 lines) Select submenu Scroll up by one page (8 lines) Open menu overview Call-up selected submenu Call SETUP of the selected machine family WELGER RP 435 MASTER E-LINK Return to the SYSTEM SERVICE menu Return to the SYSTEM SERVICE menu 49 12 Oscilloscope The oscilloscope is used for checking digital sensors, actors, and distance sensors. • see chapter „12.1 Oscilloscope for digital sensors and actors“ • see chapter „12.2 Oscilloscope for distance sensors“ The oscilloscope mode can be used to view and analyse the status of all sensors and actors during the last 500 seconds (about 8 minutes). Viewing of all signals in real time is also possible. In each diagnostic display (see chapter 8 "Diagnosis" menu) the centre button the corresponding oscilloscope. 50 leads to WELGER RP 435 MASTER E-LINK 12.1 Oscilloscope for digital sensors and actors Diagnosis page: (here: digital sensors) Measured data recording: RUN: recording is running Designation of the sensor/actor channels (see chapter 12.3.7). Page number Sensor/actor status High: damped/connected Low: uncovered/disconnected Time window here: 10 sec. set Measured data recording: HOLD: recording stopped Channels not used Cursor position here: 495.2 sec. WELGER RP 435 MASTER E-LINK Cursor 51 12.2 Oscilloscope for distance sensors Actual measurement value (in the RUN-mode, this value is refreshed all the time) (here: 2.30 V) Zoom factor (here: factor 2.5) Offset (zero point) (here: 1.0 V) Actual measurement value (in the HOLD mode the value is displayed at the cursor position) (here: 2.02 V) Cursor position (here: 490.2 sec.) 52 Cursor WELGER RP 435 MASTER E-LINK 12.3 Operating the oscilloscope 12.3.1 Paging through the oscilloscope screens You can page through the oscilloscope screens: right button left button page up. page down. 12.3.2 Start or stop recording (RUN mode / HOLD mode) Recording of the measurement data can be stopped (HOLD mode) and restarted (RUN mode) by pressing button <START-STOP>. 12.3.3 „Time window“ function The „Time window“ function serves to set the period of time corresponding to a window size, e.g.: window size T = 10 seconds window size T = 20 seconds window size T = 50 seconds window size T = 100 seconds window size T = 200 seconds window size T = 500 seconds Position the selection bar (black) on the "Time Window" function using the buttons and (see dashed circle). Set the value for the window size by means of the keys and 12.3.4 „Cursor“ function When recording has been stopped (HOLD), the "Cursor" function can be used to view all times of the course recorded before: Position the selection bar (black) on the "Cursor" function using the buttons dashed circle). and (see Move cursor to the desired position: buttons and WELGER RP 435 MASTER E-LINK 53 12.3.5 Function "Zoom" (only for the oscilloscope for analog sensors) The „Zoom“ function can be used to enlarge the displayed value range (that means the vertical scale axis). E. g.: „Zoom = 1“ means: the displayed value range comprises 100 % of the measured values. „Zoom = 2.5“ means: the displayed value range comprises 40 % of the measured values. „Zoom = 5“ means: the displayed value range comprises 20 % of the measured values. „Zoom = 10“ means: the displayed value range comprises 10 % of the measured values. Position the selection bar (black) on the "Zoom" function using the keys and Set zoom factor by means of the keys and 12.3.6 Function "Offset" (only for the oscilloscope for analog sensors) The „Offset“ function can be used to shift the origin of the displayed value range (that means the vertical scale axis). This function is used when Zoom is used; that means with a zoom factor larger than 1. Example „Zoom factor = 5“. Only 20 % of all measured values are displayed. Set Offset to 25 %. In this case the measured values 25 % to 45 % are displayed. Or, set Offset to 50 %. In this case the measured values 50 % to 70 % are displayed. Or, set Offset to 63 %. In this case the measured values 63 % to 83 % are displayed. Position the selection bar (black) on the "Offset" function using the keys and Set Offset value by means of the keys 54 and WELGER RP 435 MASTER E-LINK 12.3.7 Designation of the sensor channels and actor channels Net tying Abbreviation Sensors DZ B.D. D.S. S.W.1 S.W.2 BODN N.M. V.L. V.R. BAW Channel designation Sensors Speed Max. bale diameter Pressure switch Cutting device Abbreviation Actors B1 B2 B3 B45 Channel designation Actors Valve B1 Valve B2 Valve B3 Valve B45 Bottom door Net knife Locking device, left Locking device, right Bale ejector NETZ N.L. N.M. Net coupling Net length Net motor Channel designation Sensors Speed Max. bale diameter Pressure switch Cutting device Abbreviation Actors B1 B2 B3 B45 Channel designation Actors Valve B1 Valve B2 Valve B3 Valve B45 Bottom door Twine run left Twine run right Locking device, left Locking device, right Bale ejector GARN Twine motor Twine tying Abbreviation Sensors DZ B.D. D.S. S.W.1 S.W.2 BODN FA.L. FA.R. V.L. V.R. BAW WELGER RP 435 MASTER E-LINK 55 12.4 Overview of the button functions in the "Oscilloscope": Operation Key Page forwards left button Call-up/terminate oscilloscope centre button Page backwards right button Switch between RUN mode (recording started) and HOLD mode (recording stopped) Increase selected oscilloscope parameters - Page shown - Time window set (10s - 20s - 50s - 100s - 200s - 500s) - Cursor position (in HOLD mode only) - Offset (0..90% measuring range) (only for oscilloscope for distance sensors) - Zoom factor (1x - 2.5x - 5x - 10x) (only for oscilloscope for distance sensors) Reduce selected oscilloscope parameters - Page shown - Time window set (10s - 20s - 50s - 100s - 200s - 500s) - Cursor position (in HOLD mode only) - Offset (0..90% measuring range) (only for oscilloscope for distance sensors) - Zoom factor (1x - 2.5x - 5x - 10x) (only for oscilloscope for distance sensors) Select oscilloscope parameters - Page shown - Time window set (10s - 20s - 50s - 100s - 200s - 500s) - Cursor position (in HOLD mode only) - Offset (0..90% measuring range) (only for oscilloscope for distance sensors) - Zoom factor (1x - 2.5x - 5x - 10x) (only for oscilloscope for distance sensors) – no function – 56 WELGER RP 435 MASTER E-LINK 13 Appendix 13.1 Chronological tying process at automatic tying The value "Delay" can be set in menu SETUP (see chapter 6 "Setup" menu). TWINE TYING Buzzer Delay: 0 .. 5.0 sec 3.0 sec 8.0 sec Twine motor NET TYING Buzzer Net magnet 3.0 sec Delay: 0 .. 5.0 sec WELGER RP 435 MASTER E-LINK 3.0 sec 57