TROUBLESHOOTING M-series HEAT-PUMP HEAT-RECOVERY www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" METHOD OFF RETRIEVE ERROR-CODE • ERROR - INDICATION : – INDOOR : • INSPECTION MODE : – LAST OCCURRED ERROR. – POSSIBLE TO RESET TO “ ØØ” : » while display error : hold on/off button ↑±5 seconds • SERVICE MODE : – LAST 9 ERRORS OCCURRED – NOT POSSIBLE TO RESET. – OUTDOOR : MONITORING MODE www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 2 OVERVIEW ERROR CODES - INDOOR www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 3 OVERVIEW ERROR CODES - OUTDOOR SIDE - 1 www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 4 OVERVIEW ERROR CODES - OUTDOOR SIDE - 2 www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 5 OVERVIEW ERROR CODES - SYSTEM www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 6 OVERVIEW ERROR CODES - CENTRAL & HRV www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 7 INSPECTION & REPAIR INSTRUCTIONS • INSPECTION : – INVERTER • for COMPRESSOR. • for FAN MOTOR. – EXPANSION VALVE MOTOR – THERMISTOR – PRESSURE SENSOR • REPAIR : – REPLACEMENT INVERTER COMPRESSOR www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 8 INSPECTION INVERTER - COMPRESSOR DIODE MODULE www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" POWER MODULE Page 9 INSPECTION INVERTER - COMPRESSOR DIODE MODULE www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" POWER MODULE Page 10 INSPECTION INVERTER - COMPRESSOR www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 11 INSPECTION INVERTER - FAN MOTOR • STEP 1 : www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 12 INSPECTION INVERTER - FAN MOTOR • STEP 2 : www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 13 INSPECTION INVERTER - FAN MOTOR • STEP 3 : www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 14 INSPECTION EXPANSION VALVE MOTOR 1 2 PLUG TO PCB 3 4 5 6 normal white reverse white yellow orange blue orange blue yellow red red brown brown WHITE Ø1 RED MOTOR EXPANSION VALVE Ø3 ORANGE YELLWO Ø2Ø4 BLUE BROWN COIL Ø 1 Ø 2 Ø 3 Ø 4 www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" on off on off on off on off Page 15 STEP ( ± 5 msec) (4) 1 2 3 4 (1) INSPECTION AIR & HEX. THERMISTOR www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 16 INSPECTION THERMISTOR - DISCHARGE www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 17 INSPECTION PRESSURE SENSORS HP HP LP www.daikineurope.com LP VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 18 INSTRUCTION FOR REPLACEMENT INVERTER COMPRESSOR 1°/ RECOVER REFRIGERANT (MODE 2 - CODE 21) 2°/ REMOVE SOUND INSULATION & POWER TERMINALS 3°/ CUT PIPES BETWEEN BRAZING & COMPRESSOR 4°/ HEAT-UP PIPE AND PULL OUT ORIGINAL PIECE 5°/ REMOVE BOLTS & COMPRESSOR . 6°/ POSITION NEW COMPRESSOR 7°/ TAKE OUT CAPS (INSIDE N2) 8°/ BRAZE ALL PIPES : 8.1 ! N2 FLOW ( MAX. 0.02MPa) 8.2 ! COOL OIL EQUALIZING SEAT! 9°/ LEAK TEST. 10°/ VACUUM DRYING. 11°/ REFRIGERANT CHARGE : 11.1 WITHOUT COMPRESSOR OPERATION 11.2 WITH COMPRESSOR OPERATION : MODE 2 - CODE 20. 12°/ CONFIRM VOLTAGE & CURRENT IS EQUAL TO U/V/W . www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 19 www.daikineurope.com VS8 - CHAPTER 6 "TROUBLESHOOTING" Page 20