PROPOSED CHILDCARE FACILITY - HOWLONG, NSW 2643 HYDRAULIC SERVICES A.C. AIR CONDITIONER. R.P.Z.D. REDUCED PRESSURE ZONE DEVICE. DENOTES WARM WATER RETICULATION. ABOVE FINISHED FLOOR LEVEL. R.S.V. RELIEF STACK VENT. DENOTES HOT WATER RETICULATION. B BASIN. R.W. RAINWATER (NON POTABLE). DENOTES NON-POTABLE WATER RETICULATION. B.B. BABY BATH. S.F./S.R. SOLAR WATER FLOW/RETURN. DENOTES RAIN WATER PIPEWORK. B.M. BAINE MARIE. SHR. SHOWER. DENOTES FIRE HYDRANT PIPEWORK. BTH. BATH. SHOWER/BATH. DENOTES GAS RETICULATION. A.F.F.L. SH/BTH BUCKET TRAP FLOOR WASTE. S.I.P. SURFACE INLET PIT. DENOTES SEWER RETICULATION. B.T. BOUNDARY TRAP. S.O.P. SURFACE OUTLET PIT. DENOTES TRADE WASTE RETICULATION. B.W. BOTTLE WASHER. S.P.V. STANDARD PROPERTY VERTICAL. DENOTES STORMWATER PIPEWORK. B.W.U. BOILED WATER UNIT. S.S. STAINLESS STEEL. DENOTES SUB SOIL PIPEWORK. C.D. CHEMICAL DISPENSER. S/S.T. SOIL SEWER STACK. DENOTES REDUNDANT PIPEWORK. C.M. COFFEE MACHINE. S.T. SEWER STACK. DIRECTION OF FLOW. C.O.S. CLEAR OUT SINK. S.V.P. SEWER VENT PIPE. SERVICE CONNECTION. C.O. COMBI OVEN. S.W. STORM WATER. CAPPED END. C.S. CLEANERS SINK. T/A TO ABOVE. DENOTES PIPE DROPPER. (ELBOW) C/W COMPLETE WITH. T/B TO BELOW DENOTES PIPE DROPPER. (TEE) D.F. DRINK FOUNTAIN. T.B.C. TO BE CONFIRMED. PIPE RISER/DROPPER. D.I.C.L. DUCTILE IRON CEMENT LINED. T.F.G.L. TO FINISHED GROUND LEVEL. PIPE PENETRATING SLAB. D.I.L. DOWNSTREAM INVERT LEVEL. T.G.L. TO GROUND LEVEL. TUNDISH. D.P. DOWN PIPE. TGH. TROUGH. PIPE RISER TO TUNDISH. D.W. DISHWASHER. T.M.V. THERMOSTATIC MIXING VALVE. WATERLESS TRAP. D.W.V. DRAINAGE, WASTE, VENT. T.P.R. TEMPERATURE, PRESSURE, RELIEF. WATER METER. E.C. EVAPORATIVE COOLER. U.I.L. UPSTREAM INVERT LEVEL CHECK VALVE. E.S. EMERGENCY SHOWER. V.J.U. VERTICAL JUMP UP. DUAL NON-RETURN VALVES. E.W. EYE WASH. V.P. VANDAL PROOF. REDUCED PRESSURE ZONE DEVICE. E.W.P. EARTHENWARE PIPE. W.C. WATER CLOSET. ISOLATING VALVE. E.V. EDUCT VENT. W.M. WASHING MACHINE. ISOLATING VALVE LOCKED OPEN. F/A FROM ABOVE. W.W. WARM WATER. VALVE IN PATH BOX. F/B FROM BELOW. F.F.L. FINISHED FLOOR LEVEL. DENOTES EXPANSION VALVE. F.H.R. FIRE HOSE REEL. DENOTES PRESSURE, TEMPERATURE & VACUUM RELIEF VALVE. F.G.L. FINISHED GROUND LEVEL. WATER FILTER/STRAINER. F.S. FIRE SERVICE. DENOTES PUMP. F.W. FLOOR WASTE. G/S.T. GREY WATER SEWER STACK. H.D.P.E. HIGH DENSITY POLYETHYLENE. H.H.W.B. HEATING HOT WATER BOILER. H.L. HIGH LEVEL. H.T. HOSE TAP. H.T.V.P. SOLENOID VALVE. RV REFLUX VALVE. MS MAINTENANCE SHAFT. MH MAN HOLE. T THERMOSTATIC MIXING VALVE. TW HOT WATER TEMPERING VALVE. HOT WATER. H.W.F. HOT WATER FLOW. H.W.R. HOT WATER RETURN. H.W.S. HOT WATER SERVICE. H.W.U. HOT WATER UNIT. I.L. INVERT LEVEL. I.M. ICE MACHINE. I.O. INSPECTION OPENING. J.U. JUMP UP. K.S. KITCHEN SINK. L.S. LAB SINK. L.T. LAUNDRY TUB. N.G. NATURAL GAS. NON POTABLE RAIN WATER. O/F OVER FLOW. O.H.T. OUTSIDE HOSE TAP. O.R.G. OVERFLOW RELIEF GULLY. P.C.W. POTABLE COLD WATER. HAWKIN S STRE ET LOCALITY PLAN NOT TO SCALE DRAWING SCHEDULE: DRAWING NO. TITLE 6783-H00 6783-H01 6783-H02 6783-H03 6783-H04 6783-H05 6783-H06 COVER PAGE - LEGEND & GENERAL NOTES SITE SERVICES - SITE PLAN SANITARY DRAINAGE - FLOOR PLAN WATER & GAS SERVICES - FLOOR PLAN ROOF DRAINAGE & PENETRATIONS - ROOF PLAN FIRE TANK & PUMP DETAIL PAGE FIRE HYDRANT / HOSE REEL COVERAGES & TESTING REQUIREMENTS GAS REGULATOR/METER ASSEMBLY. HOSE TAP VANDAL PROOF. H.W. N.P.R.W. S B.T.F.W. AREA OF WORKS ET DENOTES COLD WATER RETICULATION. STRE RAINWATER OUTSIDE HOSE TAP (NON POTABLE). HIGH R.O.H.T. STRE E AIR ADMITTANCE VALVE. HUME A.A.V. T LEGEND. ABBREVIATIONS. EQUIVALENT PIPE SIZES D.N. C.U. P.E. P.B. 15 15 16 18 18 18 20 20 20 20 25 22 25 25 32 28 32 32 40 40 40 40 50 50 50 50 63 63 65 65 75 N/A 80 80 110 N/A 100 100 125 N/A 150 150 200 N/A REFERENCE TABLE 1.1 IN AS 3500 PART 1.2 WATER X.L.P.E. 16 20 25 32 40 50 63 N/A N/A N/A N/A SUPPLY DENOTES PIPEWORK RISER/DROPPER, SERVICE & PIPESIZE. FIRE HYDRANT. GROUND SPRING BALL HYDRANT COUPLING. DENOTES TWIN HEAD FIRE HYDRANT STANDPIPE. FHR FIRE HOSE REEL. FHB FIRE HYDRANT BOOSTER ASSEMBLY. FIRE BLANKET. 1,2,3,4,5 FIRE EXTINGUISHER: 1: WATER TYPE 2: FOAM TYPE 3: WET CHEMICAL TYPE 4: DRY CHEMICAL POWDER TYPE 5: CO2 TYPE NOT FOR CONSTRUCTION T1 05-02-2019 J.V. DATE CHANGE NOTE TENDER ISSUE REV DENOTES GAS REGULATOR. H.W. 65 TENDER ISSUE REVISION DESCRIPTION ADADRA Building Services Group NOTES: THE HYDRAULIC SPECIFICATION & DESIGN DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE ARCHITECTURAL DESIGN DRAWINGS AND GENERAL REQUIREMENTS IN THE ARCHITECTURAL SCHEDULE. THE HYDRAULIC SERVICE COMPONENTS NOMINATED HEREIN SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATION AND ALL RELEVANT AUTHORITIES HAVING JURISDICTION OVER THE SITE. THE HYDRAULIC CONTRACTOR SHALL COMPLY WITH THE BUILDING CODES OF AUSTRALIA "BCA", AUSTRALIAN STANDARDS/GUIDE LINES IN PARTICULAR AS-3500, AS-5601, AS-2419, AS-2441 AND ALL OTHER RELEVANT GUIDELINES ASSOCIATED WITH THE WORKS WITHIN THIS CONTRACT. THE DESIGN DRAWINGS ARE DIAGRAMMATIC ONLY AND DO NOT SHOW ALL ARCHITECTURAL AND STRUCTURAL DETAILS. ALL LEVELS AND GRADIENTS SHALL BE CONFIRMED ON-SITE PRIOR TO COMMENCEMENT OF WORKS. THE DESIGN DRAWINGS PROVIDE APPROXIMATE LOCATIONS AND MIX OF SANITARY FIXTURES AND ADDITIONAL ITEMS REQUIRING CONNECTION TO HYDRAULIC SERVICES. ALLOWANCE SHALL BE MADE FOR ALL DIVERSIONS AND MINOR ADJUSTMENTS OF PIPE WORK AND EQUIPMENT THAT MAY BE NECESSARY TO COMPLETE THE WORKS. THE HYDRAULICS CONTRACTOR SHALL LIAISE WITH ALL ASSOCIATED CONTRACTORS TO ENSURE THAT ANY POTENTIAL CLASHES OF EQUIPMENT OR SERVICE IS SUITABLY AVOIDED. ALL OF THE WORK SHALL BE CARRIED OUT BY, OR UNDER THE FULL SUPERVISION OF, A FULLY LICENSED PLUMBER IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATION. REVIEWED AND APPROVED BY THE PROJECT MANAGER AND ALL RELEVANT AUTHORITIES HAVING JURISDICTION OVER THE SITE. THE HYDRAULICS CONTRACTOR SHALL CARRY OUT NECESSARY LIAISON AND CO-ORDINATION WITH ALL RELEVANT AUTHORITIES AND THE PROJECT MANAGER TO ENSURE SATISFACTION OF THEIR REQUIREMENTS. IF ANY UNCERTAINTY EXISTS AS TO A SECTION OF THE DESIGN BEING ABLE TO COMPLY WITH THE APPROPRIATE STANDARD, THE PROJECT MANAGER SHALL BE NOTIFIED AND WRITTEN OBTAINED PRIOR TO THE COMMENCEMENT OF ANY WORK. NO CLAIMS FOR REDUNDANT WORKS SHALL BE CONSIDERED IF THE CONTRACTOR FAILS TO NOTIFY THE PROJECT MANAGER AND OBTAIN WRITTEN APPROVAL PRIOR THE COMMENCEMENT OF SUCH WORKS. ABN: 98 951 924 766 ALL PIPE DIMENSIONS SHOWN ON DESIGNS REPRESENT A NOMINAL BORE REQUIREMENT AS FOR COPPER TUBE. ALTERNATIVE PIPING MATERIALS WITH A GREATER WALL THICKNESS MUST BE SIZED TO MAINTAIN THE INTENDED NOMINAL BORE REQUIREMENT. THE CONTRACTOR SHALL ALLOW FOR ALL NECESSARY SAFETY SYSTEMS FOR THE PROPOSED WORKS WITHIN THIS CONTRACT TO COMPLY WITH THE OCCUPATIONAL HEALTH AND SAFETY ACT, INCLUDING BUT NOT LIMITED TO VEHICULAR AND PEDESTRIAN TRAFFIC MANAGEMENT, SAFE HANDLING OF MATERIALS, HOT WORKS, CONFINED SPACES, EXCAVATION AT DEPTH, WORKING AT HEIGHTS. THE CONTRACTOR SHALL PROVIDE TESTING, COMMISSIONING AND MAINTENANCE OF THE ENTIRE INSTALLATION, INCLUDING ALL SPECIFIED AND REQUIRED PROCEDURES DURING THE CONSTRUCTION PERIOD AND FOR THE DURATION OF THE MAINTENANCE PERIOD. THE CONTRACTOR SHALL SERVICE THE SYSTEM AT THEIR OWN EXPENSE DURING THE DEFECTS LIABILITY PERIOD AND CONSTRUCTION PERIOD. FIRE STOPPING: PIPES PASSING THROUGH ANY FIRE RATED ELEMENT SHALL BE APPROPRIATELY FILLED USING A SEALANT OF APPROVED MATERIAL AND FITTED WITH AN APPROVED FIRE STOP COLLAR CAPABLE OF COMPLETELY SEALING PIPE PENETRATION UNDER FIRE CONDITIONS. INTERNAL EXPOSED PIPING ADJACENT TO PLUMBING FIXTURES, INCLUDING TRAPS AND FITTINGS SHALL BE CHROMIUM PLATED FINISHED AND WHERE PASSING THROUGH A FINISHED WALL, FLOOR OR CEILING, SHALL BE FITTED WITH APPROVED CHROME PLATES, UNLESS DIRECTED OTHERWISE BY THE SITE SUPERINTENDENT. PRIOR TO PRACTICAL COMPLETION THE CONTRACTOR SHALL PROVIDE AN INDEPENDENT CERTIFICATION REPORT PREPARED BY A FIRE SERVICES CERTIFIER; AND AN INSTALLATION COMPLIANCE STATEMENT FOR THE WORKS AS INSTALLED FOR COMPLIANCE WITH LOCAL GOVERNMENT, FRNSW AND THE BCA. Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 BUILDING SERVICES CONSULTING ENGINEERING GROUP MECHANICAL ELECTRICAL HYDRAULIC FIRE OTHER Client ROB PICKETT DESIGN Project PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 Title HYDRAULIC SERVICES COVER PAGE LEGEND & GENERAL NOTES Drawn J.V. Scale Date 18-12-2018 N.T.S. @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 05-02-2019 Drawing Number 6783-H00 Revision T1 D1 45 .0 EX. AUTHORITY NATURAL GAS MAIN EX. uPVC í150 AUTHORITY SEWER MAIN AH BOUNDARY 28.35m BOUNDARY 28.35m í100 B.B. AUTHORITY WATER MAIN AHD 145.00 HAWKINS STREET EX. G.B.F.H. BOUNDARY 100.37m GATE REQUIRED FOR FIRE BRIGADE ACCESS TO ACHIEVE COVERAGE TO BUILDING. GATE SHALL BE ACCESSIBLE & LOCKED WITH 003 LOCKS. PROPOSED BOUNDARY 100.37m I.L. 144.055 INSTALL NEW í100 TAPPING TO THE EXISTING í100 AUTHORITY WATER MAIN. CONTRACTOR SHALL LIAISE WITH FEDERATION COUNCIL & PAY ALL ASSOCIATED COSTS TO FACILITATE THE INSTALLATION. CONTRACTOR SHALL LOCATE & CONFIRM EXISTING WATER MAIN SIZE & TYPE PRIOR TO COMMENCEMENT OF WORKS. S.W. PIT H03 H02 H02 í100 SEWER H02 H03 I.L. 144.487 í100 FIRE SERVICE 01 F.H.R U.I.L. 144.241 D.I.L. 143.907 í100 FIRE SERVICE í100 SEWER @ 1.65% EX. AUTHORITY NATURAL GAS MAIN T2 FHB í40 N.G. @ 2.75 kPa í100 FIRE SERVICE í100 SEWER @ 1.65% J.U. CONTRACTOR SHALL LIAISE WITH APA GROUP & PAY ALL ASSOCIATED COSTS TO FACILITATE THE SUPPLY & INSTALLATION OF THE NATURAL GAS METER/REGULATOR ASSEMBLY & SUPPLY OF NATURAL GAS TO SITE. TOTAL GAS LOAD: 530mJ/hr EX. uPVC í150 AUTHORITY SEWER MAIN 25,000L (EFFECTIVE CAPACITY) FIRE WATER BREAK TANK (í3.90m x 2.90m HIGH) C/W RING BEAM FOUNDATION TO MANUFACTURER SPECIFICATIONS COMPLYING TO AS 2304-2011. í100 B.B. AUTHORITY WATER MAIN SINGLE FIRE PUMP SKID PACKAGE C/W JACKING PUMP WITHIN ENCLOSURE. REFER DRAWING H05 FOR DETAIL. í100 SEWER @ 1.65% 1.2m WALKWAY í40 N.G. @ 2.75 kPa AHD 145.0 INSTALL NEW í100 DUAL FIRE BRIGADE BOOSTER ASSEMBLY C/W í150 BOLLARD PROTECTION. REFER DETAIL 9 ON DRAWING H04. I.L. 143.900 F/B T/A I.L. 144.783 OUTDOOR PLAY AREA í25 F.S. @ H.L. í40 P.C.W. @ H.L. EX. AUTHORITY SEWER N.G. BY APA GROUP S.P.V. I.O. T.F.G.L. I.L. 144.616 H02 í40 P.C.W. SEWER DRAINAGE BY FEDERATION COUNCIL. I.L. 143.470 í100 F.S. í100 SEWER BOUNDARY 32.00m MH í25 F.S. T/B SUPPLYING FIRE HOSE REEL WITHIN CABINET. FIRE HOSE REEL SHALL BE INSTALLED NO MORE THAN 4.0m FROM BUILDING EGRESS IN ACCORDANCE WITH NCC (BCA) 2016) REFER DETAIL 8 ON DRAWING H02. OUTDOOR PLAY AREA í100 SEWER @ 1.65% BOUNDARY 32.00m SEWER DRAINAGE CONNECTING SITE SEWER TO THE AUTHORITY SEWER MAIN SHALL BE PROVIDED BY FEDERATION COUNCIL. SEWER PROPERTY VERTICAL SHALL BE THE DEMARCATION FOR WORKS. PIT í40 N.G. @ 2.75 kPa EX. AUTHORITY SEWER 01 F.H H02 DUAL HEAD FIRE HYDRANT C/W í150 BOLLARD PROTECTION. REFER DETAIL 12 ON DRAWING H05. í100 SEWER @ 1.65% í20 P.C.W. I.L. 144.774 OUTDOOR PLAY AREA í20 P.C.W. O.H.T. í100 FIRE SERVICE í40 P.C.W. MH BOUNDARY 100.37m T2 AHD 146.2 AHD 146.0 AHD 145.8 AHD 145.6 AHD 145.4 AHD 145.2 INSTALL NEW í32 SITE WATER METER ASSEMBLY TO FEDERATION COUNCIL REQUIREMENTS. AHD 145.4 AHD 145.2 AHD 145.07 INSTALL NEW FIRE í100 ISOLATION & DOUBLE DETECTOR CHECK VALVE ASSEMBLY C/W í25 METERED BYPASS TO FEDERATION COUNCIL REQUIREMENTS. REFER DETAIL 7 ON DRAWING H02. T2 T1 EX. G.B.F.H. REV SITE SERVICES - SITE PLAN SCALE: 1:200 @ A1 08-02-2019 J.V. 05-02-2019 J.V. DATE CHANGE NOTE TENDER ISSUE TENDER ISSUE REVISION DESCRIPTION ADADRA Building Services Group ABN: 98 951 924 766 Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 h Nort 100 FIRE SERVICE TRENCHING DETAIL DETAIL NOT TO SCALE 1 - 100 MIN SEWER TRENCHING DETAIL DETAIL NOT TO SCALE 2 - DETECTABLE MARKING TAPE. 100 BEDDING AND SURROUND TO BE COMPACTED PACKING SOUND. CLEARANCES AS SHOWN. GAS TRENCHING DETAIL DETAIL NOT TO SCALE 3 - F.G.L. TOP SOIL FOR OPEN GROUND OR ROAD BASE FOR PAVEMENT. RIVER GRAVEL OR SAND COMPACTED IN 200mm LAYERS. DETECTABLE MARKING TAPE. 100 100 200 150 MIN 500 MIN 150 F.G.L. TOP SOIL FOR OPEN GROUND OR ROAD BASE FOR PAVEMENT. RIVER GRAVEL COMPACTED IN 200mm LAYERS. DETECTABLE MARKING TAPE. BEDDING AND SURROUND TO BE COMPACTED 7mm MINUS GRIT. CLEARANCES AS SHOWN. 200 DIA. D MIN DETECTABLE MARKING TAPE. BEDDING AND SURROUND TO BE COMPACTED PACKING SAND. CLEARANCES AS SHOWN. 75 MIN 100 MIN 750 MIN DIA. D 200 200 F.G.L. COMPACTED RIVER GRAVEL OR SAND BACKFILL MAXIMUM 75mm STONE. TOP SOIL FOR OPEN GROUND OR ROAD BASE FOR PAVEMENT. F.G.L. COMPACTED RIVER GRAVEL OR SAND COMPACTED IN 200mm LAYERS 750 MIN 100 300 MIN 150 TOP SOIL FOR OPEN GROUND OR ROAD BASE FOR PAVEMENT. BEDDING AND SURROUND TO BE COMPACTED PACKING SAND. CLEARANCES AS SHOWN. WATER TRENCHING DETAIL DETAIL NOT TO SCALE 4 - TENDER ISSUE NOT FOR CONSTRUCTION USE DIAL BEFORE YOU DIG INFORMATION. LOCATE ALL SERVICES BY HAND PRIOR TO EXCAVATION AS LOCATIONS ARE APPROXIMATE ONLY. NOTIFY RELEVANT UTILITY/SERVICE AUTHORITIES AS NECESSARY OF ANY WORKS TO BE CONDUCTED. THE CONTRACTOR SHALL PROVIDE FOOTPATH REINSTATEMENT TO FEDERATION COUNCIL REQUIREMENTS AND APPROVAL AND PAY ALL FEES AND COSTS FOR FOOTPATH OPENING AND REINSTATEMENT. POTHOLE LOCATE ALL SERVICES WITH HIGH PRESSURE WATER VACUUM EXCAVATION BEFORE COMMENCEMENT OF WORKS. NO MECHANICAL EXCAVATION SHALL BE ALLOWED OVER OR AROUND COMMUNICATION, GAS AND ELECTRICAL SERVICES. HIGH PRESSURE WATER VACUUM EXCAVATION ONLY. Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 BUILDING SERVICES CONSULTING ENGINEERING GROUP MECHANICAL ELECTRICAL HYDRAULIC FIRE OTHER Client ROB PICKETT DESIGN Project PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 Title HYDRAULIC SERVICES SITE SERVICES SITE PLAN Drawn J.V. Scale Date 18-12-2018 1:200 @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 08-02-2019 Drawing Number 6783-H01 Revision T2 SITE BOUNDARY PIT L.T. S.V.P. 50 B. FOYER I.L. 144.900 I.L. 143.900 K.S. K.S. S.V.P. 50 TGH. I.O. 100 MIN 100x75 D.P. 2.44 L/sec C.O.P. W.C. 100x75 D.P. 2.44 L/sec 100x75 D.P. 2.44 L/sec 100 MIN 100x75 D.P. 2.44 L/sec C.O.P. W.C. BATHROOM 2 OFFICE C.O.P. W.C. 100x75 D.P. 1.65 L/sec OUTDOOR PLAY AREA í25 ISOLATION VALVE. í100 F.W. C.O.P. W.C. PLAN ROOM 5 (4-5yr) MEALS AREA / T2 ROOM 4 (4-5yr) STORE 2 ROOM 3 (3-4yr) RECEPTION PLANNING 100x75 D.P. 2.44 L/sec 800 MIN T2 I.L. 144.783 F.F.L. 145.400 í100 D.P. 5.24 L/sec 370 MIN I.O. í100 SEWER @ 1.65% KITCHEN í100 F.W. K.S. 50 MAX CLEANERS L'DRY O.R.G. 900 - 1100 A.F.F.L. 1400 - 2400 A.F.F.L. 1773 - 2773 A.F.F.L. B. CLEARANCE SHALL COMPLY WITH AS 2441-2005 T.O.P. 9.750 ROOM 1 (2-3yr) I.L. 144.900 100 MIN W.M. 100x75 D.P. 2.44 L/sec BOTTLE K.S. PROVIDE BRACKET TO MOUNT HOSE REEL TO ENSURE 50mm FROM FRONT OF HOSEREEL TO BACK OF DOOR. í25 P.C.W. í100 F.W. K.S. 100 MIN W.M. í100 F.W. C.S. TGH. S.V.P. 50 W.C. C.O.P. STORE BATHROOM 1 SLEEPING STAFF BATH í100 F.W. I.L. 144.900 J.U. I.O. T.F.G.L. PORCH C.O.P. W.C. 2x í50 WASHING MACHINE WASTE TRAP C/W A.A.V. REFER DETAIL 12 ON DRAWING DRYER COVERED EATING AREA U.I.L. 144.241 D.I.L. 143.907 I.L. 144.824 100x75 D.P. 2.44 L/sec STORE 1 í100 SEWER @ 1.65% S.V.P. 50 DIS. W/C H01 m WALKWAY B. I.O. C.O.P. W.C. B.B. STAFF K.S. I.O. W.C. C.O.P. B. I.L. 144.616 I.O. í100 SHR. K.S. 100x75 D.P. 2.44 L/sec I.L. 143.900 100x75 D.P. 2.44 L/sec W.C. C.O.P. BIN STORE AREA í100 SHR. I.O. 100x75 D.P. 2.44 L/sec I.O. OUTDOOR í100 SEWER @ 1.65% PLAY AREA 100 MIN í100 SEWER @ 1.65% I.L. 144.151 I.O. ROOM 2 (0-2yr) I.L. 144.055 I.L. 144.353 545 T2 GATE REQUIRED FOR FIRE BRIGADE ACCESS TO ACHIEVE COVERAGE TO BUILDING. GATE SHALL BE ACCESSIBLE & LOCKED WITH 003 LOCKS. í100 SHR. I.O. 100x75 D.P. 2.44 L/sec I.L. 144.774 í100 SEWER @ 1.65% F.F.L. OUTDOOR PLAY AREA ELEVATION FIRE HOSE REEL IN CABINET STORE I.L. 144.487 DETAIL NOT TO SCALE 8 - SITE BOUNDARY SANITARY DRAINAGE - FLOOR PLAN BOUNDARY 100.37m h Nort SCALE: 1:100 @ A1 HYDRAULIC CONTRACTOR SHALL LIAISE WITH MECHANICAL CONTRACTOR TO FACILITATE INSTALLATION OF A.C. TUNDISHES. ALL TUNDISHES SHALL BE COMPLETE WITH WATERLESS TRAP WHEN NOT DISCHARGING TO A FIXTURE. TENDER ISSUE ISOLATION VALVES LOCKED OPEN AND TAGGED TO COMPLY WITH AS.2419-2005. DR. 25 DR. DR. DR. SIZE MWWP 1600 kPa TEMP 1° to 90°C .RD OUTLET INLET 1200 í150 N.B. HEAVY DUTY GALVANIZED PIPE SET IN CONCRETE. TOP OF CUPBOARD PRESSURE GAUGE. 450x450x450 CONCRETE SURROUND. CONCRETE TO FINISH 25mm ABOVE F.G.L. Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 2000 í100 EPOXY LINED CAST IRON PIPE RISER WRAPPED WITH DENSO TAPE. 800 1000 DUCK FOOT BEND WRAPPED IN DENSO TAPE. (TYPICAL) WASHING MACHINE DISCHARGE TRAP DETAIL - ELECTRICAL HYDRAULIC FIRE OTHER Client ROB PICKETT DESIGN Project DETAIL NOT TO SCALE 6 - PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 CONCRETE THRUST BLOCK. í100 WATER SUPPLY TO FIRE HYDRANTS. í100 FROM TOWNS MAIN SUPPLY. 5 CHANGE NOTE ABN: 98 951 924 766 MECHANICAL í50 WASHING MACHINE WASTE TRAP. F.F.L. DETAIL DATE Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 TABLE 'E' FLANGE. (TYPICAL) NOT TO SCALE REVISION DESCRIPTION BUILDING SERVICES CONSULTING ENGINEERING GROUP W.M. í150mm BOLLARD 05-02-2019 J.V. Building Services Group F.G.L. í600 08-02-2019 J.V. ADADRA P WASHINE MACHINE FLEXIBLE WASTE PIPE INSTALLED TO MANUFACTURER'S GUIDELINES TO BE LEVEL WITH TOP OF WASHING MACHINE. TENDER ISSUE TENDER ISSUE REV VENTS FILL PIPE WITH CONCRETE. í50 A.A.V. 100mm CLEARANCE FROM UNDERSIDE BENCH T2 T1 í100 GALVANISED PIPE. BACKFLOW PREVENTER AS/NZS 2845.1 Lic 1324 DR. PIPEWORK UPSTREAM OF CHECK VALVE SHALL NOT BE GALVANISED STEEL IN ACCORDANCE WITH AS 3500. NOT FOR CONSTRUCTION í100 DOUBLE DETECTOR CHECK VALVE C/W í25 METER BYPASS AND DUAL CHECK VALVE TO FEDERATION COUNCIL REQUIREMENTS. FLANGE/SOCKET JOINT TO WATER SUPPLY. FLANGE/SOCKET JOINT TO WATER SUPPLY. í100 FIRE SERVICE ISOLATION & DOUBLE DETECTOR CHECK VALVE ASSEMBLY DETAIL DETAIL NOT TO SCALE 7 - FIXTURE WASTE SCHEDULE FIXTURE W.C. BASIN SHOWER KITCHEN SINK TRAP SIZE WASTE SIZE í100 í100 í40 í40 í100 í100 í50 í50 LAUNDRY TROUGH í50 í50 WASHING MACHINE í50 - CLEANER'S SINK WASH TROUGH. FLOOR WASTE í50 í50 í100 í50 í50 í100 A.C./H.W.S. TUNDISHES N/A í40 DESCRIPTION SET-OUT T.B.C. RISER IN-WALL í100 FLOOR GRATE INCLUDE WASTE STRAINER DISCHARGING TO OVERFLOW RELIEF GULLY. DISCHARGING TO LAUNDRY TROUGH. DISCHARGING TO FLOOR WASTE. í100 FLOOR GRATE WATERLESS TRAP REQUIRED WHEN NOT DISCHARGING TO FIXTURE TRAP. Title HYDRAULIC SERVICES SANITARY DRAINAGE FLOOR PLAN Drawn J.V. Scale Date 18-12-2018 1:100 @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 08-02-2019 Drawing Number 6783-H02 Revision T2 H01 í40 N.G. í32 P.C.W. @ H.L. í25 H.W.F. @ H.L. í25 H.W. í25 P.C.W. L'DRY L.T. T2 í15 HOT WATER TEMPERING VALVE WITHIN RECESSED WALL BOX C/W LOCKABLE ACCESS PANEL @ MAX. 1800 A.F.F.L. SUPPLYING BASIN ONLY. B. TW í20 P.C.W. T/B í32 P.C.W. @ H.L. í25 H.W.F. @ H.L. í20 P.C.W. @ H.L. í25 H.W.F. @ H.L. K.S. K.S. T/B TGH. í25 H.W.F. @ H.L. T2 O.H.T. BATHROOM 2 í25 H.W.F. @ H.L. W.C. T T2 T1 W.C. W.C. SHR. O.H.T. 08-02-2019 J.V. 05-02-2019 J.V. DATE CHANGE NOTE TENDER ISSUE TENDER ISSUE REV T/B í20 P.C.W. @ H.L. T/B H01 H.T. í25 P.C.W. @ H.L. í25 H.W.F. @ H.L. í25 H.W.F. @ H.L. í15 THERMOSTATIC MIXING VALVE WITHIN RECESSED WALL BOX C/W LOCKABLE ACCESS PANEL BELOW BENCH WITHIN CUPBOARD. PRE-SET @ MAX. 40.5øC. í15 VANDAL PROOF HOSE TAP C/W VACUUM BREAKER HOSE CONNECTION @ 600 A.F.F.L. í20 P.C.W. @ H.L. 1 T2 ROOM 4 (4-5yr) STORE 2 í32 P.C.W. @ H.L. í25 H.W.F. @ H.L. ROOM 3 (3-4yr) PLANNING í15 P.C.W. í15 H.W. K.S. í32 P.C.W. @ H.L. í20 H.W. @ H.L. í32 P.C.W. @ H.L. í25 H.W.F. @ H.L. OFFICE í40 P.C.W. T/B COVERED EATING AREA í40 P.C.W. @ H.L. í25 H.W.F. @ H.L. RECEPTION í40 P.C.W. @ H.L. í100 FIRE SERVICE í100 SEWER @ 1.65% í100 FIRE SERVICE í100 SEWER @ 1.65% T/B W.M. í32 H.W.F. í32 P.C.W. T/B í15 H.W. í20 P.C.W. T/B W.C. H01 í20 í25 4 í20 NATURAL GAS ISOLATION VALVE FOR COOKTOP. GAS LOAD: 130mJ/hr í25 F.S. T/B SUPPLYING FIRE HOSE REEL WITHIN CABINET. FIRE HOSE REEL SHALL BE INSTALLED NO MORE THAN 4.0m FROM BUILDING EGRESS IN ACCORDANCE WITH NCC (BCA) 2016) F/B C.S. í15 í20 í32 H.W.F. @ H.L. í20 H.W.R. @ H.L. í32 P.C.W. @ H.L. í15 THERMOSTATIC MIXING VALVE WITHIN RECESSED WALL BOX C/W LOCKABLE ACCESS PANEL @ MAX. 1800 A.F.F.L. PRE-SET @ MAX. 40.5øC. T í25 H.W.F. @ H.L. í25 P.C.W. @ H.L. FOYER B. T/B í20 P.C.W. í15 H.W. 1 STORE 1 DIS. W/C W.C. í40 N.G. @ 2.75 kPa STORE í20 H.W.R. @ H.L. H.W.S H.W.S W.M. í32 H.W.F. @ H.L. í32 P.C.W. @ H.L. í25 H.W.F. @ H.L. T2 1 01 F.H.R í25 F.S. @ H.L. K.S. í25 H.W.F. @ H.L. K.S. T/B T/B í20 VANDAL PROOF OUTSIDE HOSE TAP C/W VACUUM BREAKER HOSE CONNECTION @ 800 A.F.G.L. (TYPICAL) ROOM 5 (4-5yr) MEALS AREA / STAFF í100 FIRE SERVICE í100 SEWER @ 1.65% í25 H.W.F. @ H.L. í40 P.C.W. @ H.L. TGH. í15 THERMOSTATIC MIXING VALVE WITHIN RECESSED WALL BOX C/W LOCKABLE ACCESS PANEL @ MAX. 1800 A.F.F.L. PRE-SET @ MAX. 40.5øC. í15 H.W. í20 P.C.W. K.S. INSTALL NEW NATURAL GAS BOOSTED CONTINUOUS FLOW HOT WATER MULTI-PAK (2x BURNERS) C/W SECONDARY CIRCULATING PUMP & FLUE KIT. GAS LOAD: 400mJ/hr (200mJ EACH) O.H.T. í20 P.C.W. KITCHEN B. F/B W.C. BOTTLE T T/B B. ROOM 2 (0-2yr) SLEEPING í20 H.W. í20 P.C.W. T/B W.C. T/B T K.S. STAFF BATH T/B PORCH B.B. í20 P.C.W. @ H.L. í15 W.W. @ H.L. BIN STORE AREA SHR. DRYER í20 N.G. @ 2.75kPa í20 H.W.R. @ H.L. í32 P.C.W. @ H.L. W.C. ROOM 1 (2-3yr) í15 THERMOSTATIC MIXING VALVE WITHIN RECESSED WALL BOX C/W LOCKABLE ACCESS PANEL BELOW BENCH WITHIN CUPBOARD. PRE-SET @ MAX. 40.5øC. BATHROOM 1 H01 O.H.T. T/B O.H.T. SHR. CLEANERS W.C. REVISION DESCRIPTION ADADRA Building Services Group ABN: 98 951 924 766 í20 VANDAL PROOF OUTSIDE HOSE TAP C/W VACUUM BREAKER HOSE CONNECTION @ 800 A.F.G.L. (TYPICAL) Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 í15 W.W. @ H.L. BUILDING SERVICES CONSULTING ENGINEERING GROUP MECHANICAL ELECTRICAL HYDRAULIC FIRE OTHER Client WATER & GAS SERVICES - FLOOR PLAN ROB PICKETT DESIGN SCALE: 1:50 @ A1 Project PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 WATER SERVICHOTES WATER SCHEDULE COLD WATER FIXTURE W.C. BASIN SHOWER KITCHEN SINK DISHWASHER WASHING MACHINE LAUNDRY TROUGH BABY BATH CLEANER'S SINK WASH TROUGH MINI-STOP MINI-STOP N/A í15 í15 (W.W.) í15 í15 FLICK MIXER (W.W.) í15 í15 N/A í15 í15 í15 í15 í15 í15 (W.W.) í15 í15 í15 N/A í15 Title DESCRIPTION 200 A.F.F.L. (T.B.C. ON-SITE) 600 A.F.F.L. 950 A.F.F.L. 600 A.F.F.L. 600 A.F.F.L. WALL BREACH 1,000 A.F.F.L. 500 A.F.F.L. 600 A.F.F.L. 600 A.F.F.L. 200 A.F.F.L. HYDRAULIC SERVICES WATER & GAS SERVICES FLOOR PLAN h Nort Drawn J.V. Scale Date 18-12-2018 1:50 @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 08-02-2019 Drawing Number Revision TENDER ISSUE NOT FOR CONSTRUCTION 6783-H03 T2 ROOF D T2 100x75 D.P. 2.44 L/sec ROOF C ROOF E ROOF A1 100x75 D.P. 2.44 L/sec 100x75 D.P. 2.44 L/sec AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: ROOF A1 100x75 D.P. 2.44 L/sec ROOF B1 2x H.W.S. FLUE ROOF B1 AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: ROOF B2 S.V.P. 50 100x75 D.P. 2.44 L/sec S.V.P. 50 1 OFF í65 HYDRANT VALVE C/W HYDRANT LOCKING WHEEL (PLASTIC) + 003 LOCK. 1600mm S.V.P. 50 100x75 D.P. 1.65 L/sec ROOF F 500mm ROOF A2 150 MIN ROOF G ROOF 1b ROOF L 100x75 D.P. 2.44 L/sec 1600mm ROOF H S.V.P. 50 AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = 5m² = 15ø = 135mm/hr/5min = 0.21 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: 100x75 D.P. 2.44 L/sec AREA: SLOPE: A.R.I. (1:100yr): FLOW: DOWNPIPES: BOX GUTTER (WxD): SUMP (WxLxD): OVERFLOW: LOC: 1500mm MINIMUM 100x75 D.P. 2.44 L/sec 100x75 D.P. 2.44 L/sec 100x75 D.P. 2.44 L/sec = 96m² = 15ø = 135mm/hr/5min = 4.08 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = = = = = = = = = = 16m² = 15ø = 135mm/hr/5min = 4.25 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) = 2m² = 15ø = 135mm/hr/5min = 0.09 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF F = 2m² = 15ø = 135mm/hr/5min = 0.09 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = 80m² = 15ø = 135mm/hr/5min = 3.40 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF J = 34m² = 15ø = 135mm/hr/5min = 1.45 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = 88m² = 15ø = 135mm/hr/5min = 3.74 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF L = 14m² = 15ø = 135mm/hr/5min = 0.60 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF 1a 30m²+60m²+9m² 5ø 175mm/hr/5min 5.24 L/sec 1x í100 400 x 110mm 400 x 600 x 150mm í100 27mm AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = 60m² = 15ø = 135mm/hr/5min = 2.55 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF 1b ROOF 2 AREA: = 9m² SLOPE: = 10ø A.R.I. (1:20yr): = 135mm/hr/5min FLOW: = 0.29 L/sec DISCHARGING TO ROOF 1a AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = 41m² = 8ø = 135mm/hr/5min = 1.65 L/sec = 1x 100x75mm = 7,107mm (150 HALF ROUND) T2 ROOF DRAINAGE & PENETRATIONS - ROOF PLAN SCALE: 1:100 @ A1 F.G.L. ROOF C AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: = 51m² = 15ø = 135mm/hr/5min = 2.17 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: BOOSTER ROOF K ROOF B2 ROOF H 100x75 D.P. 2.44 L/sec ROOF J FIRE HYDRANT AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: ROOF K ROOF A3 FH AREA: = 60m² SLOPE: = 15ø A.R.I. (1:20yr): = 135mm/hr/5min FLOW: = 4.25 L/sec DISCHARGING TO ROOF 1a ROOF E AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: ROOF 2 ROOF A3 AREA: SLOPE: A.R.I. (1:20yr): FLOW: DOWNPIPES: GUTTER X-SECTION: ROOF G í100 D.P. + SUMP 5.24 L/sec 100mm DUAL BOOSTER HEAD. = 98m² = 15ø = 135mm/hr/5min = 4.17 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF D ROOF 1a 450 MINIMUM CLEARANCE = 8m² = 15ø = 135mm/hr/5min = 4.25 L/sec = 100x75mm = 10,186mm (200 HALF ROUND) ROOF A2 CONCRETE BASE. í100 FROM TOWNS MAIN SUPPLY. THRUST BLOCK í100 WATER SUPPLY TO FIRE HYDRANTS. CLOSED CABINET CEILING 710 360 1 OFF í65 HYDRANT VALVE C/W HYDRANT LOCKING WHEEL (PLASTIC) + 003 LOCK. 350 230 COLD WATER ISOLATING VALVE. 295 60 60 NOTICE OF TEST/WORKING PRESSURES. 202 100 í100 WATER SUPPLY TO FIRE HYDRANTS. 20 T.W. P.C.W. P.C.W. OUT OUT IN 38 75 FRONT VIEW SIDE VIEW THERMOSTATIC MIXING VALVE C/W COLD WATER BYPASS WITHIN WALL BOX DETAIL. DETAIL NOT TO SCALE DETAIL NOT TO SCALE 9 - CHANGE NOTE ABN: 98 951 924 766 Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 GAS Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 100 140 230 650 10 BUILDING SERVICES CONSULTING ENGINEERING GROUP MECHANICAL ELECTRICAL HYDRAULIC FIRE OTHER Client ROB PICKETT DESIGN - Project PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 INTERNAL HOT WATER MULTI-PAK DETAIL (2x BURNERS) NOT TO SCALE í100 SINGLE FIRE HYDRANT BOOSTER ASSEMBLY C/W SINGLE CHECK VALVE WITHIN CABINET DETAIL DATE Building Services Group DETAIL OPEN CABINET REVISION DESCRIPTION ADADRA HOT WATER COLD WATER 260 400 530 620 75 415 77.5 08-02-2019 J.V. 05-02-2019 J.V. TENDER ISSUE TENDER ISSUE REV STAGING VALVE 260 í150 VALVE LOCKED IN THE FULLY OPEN POSITION C/W 003 LOCKS. CONCRETE BASE. THRUST BLOCK 77.5 COLD WATER BYPASS VALVE H.W. IN í100 SINGLE CHECK VALVE T2 T1 1800 STAINLESS STEEL RECESSED WALL BOX C/W STAINLESS STEEL LOCKABLE ACCESS PANEL. 230 350 100mm DUAL BOOSTER HEAD. 660 570 750mm - 1200mm MIN 450mm F.G.L. í100 FROM TOWNS MAIN SUPPLY. HOT WATER ISOLATING VALVE. í25 LOCKED DRAIN VALVE. 750mm MINIMUM - 1200mm MAXIMUM BLOCK PLAN OF SITE PRESSURE GAUGE. 11 Title HYDRAULIC SERVICES ROOF DRAINAGE & PENETRATION ROOF PLAN - h Nort Drawn J.V. Scale Date 18-12-2018 1:100 @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 08-02-2019 Drawing Number Revision TENDER ISSUE NOT FOR CONSTRUCTION 6783-H04 T2 í150 BOLLARDS. REFER DETAIL 5 ON DRAWING H02. (TYPICAL) T2 FIRE PUMP COOLANT DISCHARGING TO GRATED STORM WATER PIT. CONNECT STORM WATER PIT TO SITE STORM WATER. í100 FIRE BRIGADE SINGLE BOOSTER ASSEMBLY WITHIN WEATHERPROOF CABINET ON CONCRETE SLAB. REFER DETAIL 9 ON DRAWING H04. PROVIDE STORAGE TANK ACCESS LADDER TO COMPLY WITH AS 2304-2011. FIRE TANK WATER LEVEL INDICATOR VISIBLE FROM FIRE BRIGADE BOOSTER ASSEMBLY. PUMP RUN SENDER TO SMS AUTO DIALLER. CONNECTION INTERFACED TO LOCAL ALARM/SECURITY. SINGLE FIRE PUMP SKID PACKAGE C/W JACKING PUMP WITHIN ENCLOSURE. 1 OFF SINGLE DIESEL FIRE HYDRANT PUMP & 1 OFF ELECTRIC JACKING PUMP COMPLYING TO AS-2941-2013. CONNECT PUMPSET CONTROLLER TO ELETRICAL SUPPLY AT SITE MAIN ELECTRICAL SWITCHBOARD. 100% PUMP DUTY: 5 L/sec @ 850 kPa 130% PUMP DUTY: 6.5 L/sec @ 680 kPa MINIMUM INTERNAL DIMENSIONS: 2.80m x 1.00m x 2.10m (HIGH) MINIMUM CLEARANCE OF 1.00m REQUIRED AROUND FIRE PUMP ENCLOSURE. HATCHED AREA DENOTES INLET DISCHARGE RESTRICTION ZONE FOR TANK SUCTION. NO INLET SHALL BE INSTALLED WITHIN THIS ZONE IN ACCORDANCE WITH AS 2304-2011. 2 OFF BERMAD FAST FILL INLET VALVES & 1 OFF MANUAL INLET VALVE DISCHARGING INTO TANK @ HIGH LEVEL. 900 x 600 ACCESS HATCH í150 STORAGE TANK OVERFLOW PIPEWORK DISCHARGING TO S.W. PIT. í100 FIRE PUMP DISCHARGE PIPE SHALL HAVE A PRESSURE GAUGE, í100 CHECK VALVE, & í100 ISOLATION VALVE LOCKED OPEN & TAGGED TO COMPLY WITH AS 2941. TANK VENT 25,000L (EFFECTIVE CAPACITY) FIRE WATER BREAK TANK (í3.90m x 2.90m HIGH) C/W RING BEAM FOUNDATION TO MANUFACTURER SPECIFICATIONS COMPLYING TO AS 2304-2011. PUMP ENCLOSURE SKID FRAME SECURELY MOUNTED TO MANUFACTURER'S INSTALLATION GUIDELINES TO A REINFORCED CONCRETE GROUND SLAB & PATH SURROUND. DIMENSIONS: 3.10m x 1.30m x 150mm THICK OR TO STRUCTURAL ENGINEER'S DETAIL. CONCRETE TANK BASE / RING BEAM TO MANUFACTURER'S SPECIFICATIONS. í100 FIRE ISOLATION VALVE & DOUBLE DETECTOR CHECK VALVE C/W í25 METERED BY-PASS SUPPLYING FIRE BREAK TANK & BOOSTER ASSEMBLY. í150 TANK SUCTION OS&Y VALVE LOCKED OPEN & TAGGED TO COMPLY WITH AS 2419. (TYPICAL) 100mm MINIMUM CLEARANCE REQUIRED AROUND HYDRANT VALVE HANDLE. BOUNDARY FENCE PLAN T2 í65 HYDRANT VALVE 'FRNSW' STORTZ CONNECTIONS WITH CHAIN AND CAP. HYDRANT LOCKING WHEEL AND 003 LOCKS. HORIZONTAL OR SLOPING NOT MORE THAN 35ø. í100 GALVANISED TEE. 750 - 1200 í100 FIRE SERVICE í40 P.C.W. WATER METER 750 MIN CL ELECTRICAL POWER CONDUIT TO M.S.B. BY MAIN ELECTRICAL CONTRACTOR. COMMUNICATION LANDLINE CONNECTION CONDUIT BY MAIN ELECTRICAL CONTRACTOR. í100 FROM MAIN 750 MIN í150 BOLLARD PROTECTION REFER DETAIL 5. 100 MIN REMOVABLE DOOR PANELS C/W VENTILATION FOR PUMP OPERATION. 350 1 OFF 125x100 LARGE BORE SUCTION CONNECTION. 2 OFF 65 SMALL BORE SUCTION CONNECTION. 1500 CL í100 GALVANIZED IRON HYDRANT RISER. MINIMUM 1.00m CLEARANCE AROUND FIRE PUMP ENCLOSURE. PIPE WRAPPED WITH DENSO TAPE. F.G.L. í80 ANNUBAR TEST PIPE DISCHARGING INTO TANK @ HIGH LEVEL C/W ISOLATION VALVE LOCKED CLOSED (003) & í15 FLOW TEST PAP ON PIPE RISER MINIMUM 1.00m FROM ANY CHANGE IN DIRECTION FOR HYDRANT SYSTEM TESTING. PROVIDE SIGNAGE ADJACENT VALVE DENOTING "ANNUBAR TEST VALVE". FIRE WATER BREAK TANK & PUMP SET DETAIL SCALE: 1:100 @ A1 DUCK FOOT BEND DENSO WRAPPED. 450x450x450 CONCRETE SURROUND. CONCRETE TO FINISH 25mm ABOVE F.G.L. CONCRETE THRUST BLOCK. TABLE "E" FLANGE (TYPICAL). ELEVATION í100 TANK INLET BOX. (TYPICAL) 300 CL 300 300 CL 300 TANK VENT INSTALLED ON ROOF OF TANK IN ACCORDANCE WITH AS2304 - CLAUSE 7.4.1. 900x600 ACCESS HATCH STORAGE TANK ACCESS LADDER TO COMPLY WITH AS 2304-2011. í100 TANK SUPPLY í100 TANK SUPPLY í100 TANK SUPPLY FIRE HYDRANT TANK 25 000 LITRES EFFECTIVE CAPACITY QUICK FILL VALVE E í150 O/F WATER LEVEL FLOAT. (TYPICAL) QUICK FILL VALVE í100 BERMAD FAST FILL. (TYPICAL) í100 MANUAL FILL VALVE. 1x í65 LANDING VALVE LOCKED CLOSED FOR INFLOW TESTING. (003 LOCKS) í100 GEAR OPERATED BUTTERFLY VALVE LOCKED IN THE FULLY OPEN POSITION (003 LOCKS). í150 OS&Y VALVE 900 F 05-02-2019 J.V. REVISION DESCRIPTION DATE CHANGE NOTE Building Services Group ABN: 98 951 924 766 í150 Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 135 F.S.L. F.G.L. í50 SLUDGE VALVE. 08-02-2019 J.V. ADADRA í150-200 REDUCER. 150 F.S.L. TENDER ISSUE TENDER ISSUE REV 135 150 1 OFF 125x100 LARGE BORE SUCTION CONNECTION C/W BUTTERFLY VALVE. LOCKED CLOSED (003) 450 í150 í150 OVERFLOW 1200 400 2 OFF 65mm SMALL BORE SUCTION CONNECTIONS C/W ISOLATION VALVES. LOCKED CLOSED (003) T2 T1 100 MIN CL 1200 í600 ACCESS HATCH - FIRE TANK WATER LEVEL INDICATOR VISIBLE FROM FIRE BRIGADE BOOSTER ASSEMBLY. 1/2 í100 GEAR OPERATED BUTTERFLY VALVE LOCKED IN THE FULLY OPEN POSITION (003 LOCKS). 12 í400 WATER LEVEL í25 ANNUBAR PAP CAPPED. MIN. 10x PIPE DIAMETER FROM NEAREST BEND. (TYPICAL) DETAIL NOT TO SCALE í80 ANNUBAR TEST PIPE TANK DISCHARGE. í15 FLOAT SUPPLY SIGNAGE TO COMPLY WITH AS 2419.1 CLAUSE 11.3.3.1 FIRE HYDRANT RISER & BOLLARDS DETAIL í400 VORTEX PLATE C/W MINIMUM 150mm CLEARANCE BELOW. (TYPICAL) í80 ANNUBAR í150 SUCTION í150 OVERFLOW í150 OVERFLOW í100 TANK SUPPLY í100 TANK SUPPLY TO PUMP Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 F.G.L. BUILDING SERVICES CONSULTING ENGINEERING GROUP 450 x 450 x 450 (NOMINAL DEPTH) STORMWATER PIT PRE-CAST CONCRETE OR POURED IN-SITU C/W HEAVY DUTY CLASS D GALVANISED GRATED LID. MECHANICAL ELECTRICAL HYDRAULIC FIRE OTHER Client í150 STORMWATER DISCHARGING TO SITE STORM WATER. REFER CIVIL DOCUMENTATION. ROB PICKETT DESIGN Project í150 TANK OVERFLOW DISCHARGING TO S.W. PIT. PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 FIRE WATER BREAK TANK ELEVATION SCHEMATIC DETAIL Title HYDRAULIC SERVICES FIRE TANK & PUMP DETAIL PAGE NOT TO SCALE @ A1 h Nort Drawn J.V. Scale Date 18-12-2018 N.T.S. @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 08-02-2019 Drawing Number Revision TENDER ISSUE NOT FOR CONSTRUCTION 6783-H05 T2 LEGEND. PROPOSED CHILDCARE FACILITY - HOWLONG, NSW 2643 DENOTES FIRE HYDRANT COVERAGE (MAX. 60m) DENOTES INTERNAL FIRE HYDRANT COVERAGE (MAX. 30m) DENOTES FIRE HOSE REEL COVERAGE (MAX. 36m) FIRE HYDRANT / HOSE REEL COVERAGES & TESTING REQUIREMENTS SCALE 1:200 @ A1 DENOTES HOSE FROM HYDRANT TO TRUCK (MAX. 20m) 05-02-2019 DENOTES AREA NOT COVERED. DENOTES SPRAY (MAX. 10m F.H./4m F.H.R.) FIRE HYDRANT. DENOTES TWIN HEAD FIRE HYDRANT STANDPIPE C/W NSW STORZ COUPLINGS. FHR BOUNDARY 100.37m AH D GATE REQUIRED FOR FIRE BRIGADE ACCESS. GATE SHALL BE LOCKED (003 LOCKS). 145 BOUNDARY 28.35m BOUNDARY 28.35m í100 B.B. AUTHORITY WATER MAIN AHD 145.00 HAWKINS STREET EX. G.B.F.H. FIRE HOSE REEL. .0 PROPOSED BOUNDARY 100.37m SITE BOUNDARY PIT 01 F.H 56.0m F.H. COVERAGE 10 .0 m OUTDOOR PLAY AREA M IN IM CLEANERS STORE KITCHEN L'DRY ROOM 1 (2-3yr) . CO VER AGE F.H. R 36.0 m STORE 1 COVERED EATING AREA ROOM 5 (4-5yr) MEALS AREA / ROOM 4 (4-5yr) STORE 2 OUTDOOR PLAY AREA h Nort BATHROOM 2 í100 B.B. AUTHORITY WATER MAIN 36.0m F.H.R. COVERAGE 47.0m F.H. COVERAGE ROOM 3 (3-4yr) PLANNING OFFICE AHD 145.0 FIRE BRIGADE BOOSTER ASSEMBLY. BATHROOM 1 BOTTLE ROOM 2 (0-2yr) SLEEPING DIS. W/C F.H.R RECEPTION PORCH 01 FOYER STAFF BOUNDARY 32.00m 1.2m WALKWAY BOUNDARY 32.00m STAFF BATH BIN STORE AREA UM FHB TENDER ISSUE FIRE PUMPSET. NOT FOR CONSTRUCTION OUTDOOR PLAY AREA STORE T2 T1 BOUNDARY 100.37m 05-02-2019 J.V. REVISION DESCRIPTION DATE CHANGE NOTE Building Services Group ABN: 98 951 924 766 AHD 146.2 AHD 146.0 AHD 145.8 AHD 145.6 AHD 145.4 T2 08-02-2019 J.V. ADADRA AHD 145.2 AHD 145.4 AHD 145.2 AHD 145.07 EX. G.B.F.H. REV SITE BOUNDARY FIRE TANK. TENDER ISSUE TENDER ISSUE Albury 558 Hume Street, Albury NSW 2640 Ph: 02 60214580 Fax: 02 60235489 Darwin Suite 4, 60 Winnellie Road, Winnellie NT 0821 Ph: 08 89844246 Fax: 08 89843847 BUILDING SERVICES CONSULTING ENGINEERING GROUP MECHANICAL ELECTRICAL HYDRAULIC FIRE OTHER Client ROB PICKETT DESIGN FLOW TESTING REQUIREMENTS: EQUIPMENT REQUIRED: - 1x MACROMETER/APPROVED TESTING DEVICE PER 10 L/SEC REQUIRED TO FLOW. - 1x PRESSURE GAUGE Project PROPOSED CHILDCARE FACILITY 89-93 HAWKINS STREET, HOWLONG NSW 2643 Title HYDRANT TESTING METHOD: 1) CONNECT INDIVIDUAL MACROMETER/APPROVED TESTING DEVICE TO HYDRANT 01 LANDING VALVES. FIRE HYDARNT / HOSE REEL COVERAGES & TESTING REQUIREMENTS SITE PLAN 2) LOCATE PRESSURE GAUGE AT FIRE ISOLATION & CHECK VALVE ASSEMBLY TO MEASURE RESIDUAL. Drawn J.V. 3) RUN HYDRANT 01 LANDING VALVES TO 10 L/sec EACH (20 L/sec TOTAL) & MEASURE THE RESIDUAL PRESSURE. Scale HYDRANT SYSTEM MUST ACHIEVE: - 10 L/sec @ 700 kPa (BOOSTER) - 5 L/sec @ 700 kPa (100% PUMP DUTY) Date 18-12-2018 1:200 @ A1 Drawing Reference 6783 - HYD LAYOUT Plotted Date 08-02-2019 Drawing Number 6783-H06 Revision T2