Slender Beams (Beams: ACI 318)
Spacing of lateral supports for a beam shall not exceed 50*b.
1
In the program the lateral supports are taken as the distance between the faces of the supports, and for
simplifica on, b is taken as the web width bw
IF above check fails then a Warning and a text 'Slender span' or 'Over wide distance between lateral
supports' is displayed.
Effects of lateral eccentricity of load are considered in determining spacing of lateral supports.
Parent topic
• Beam Design to ACI 318
1. ACI 318-08:2008 and ACI 318-11:2011 Sec on 10.4