Brochure EMI Test System (EMI-9KA/EMI-9KB) Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Lead in CFL & LED Test Instruments Rev. 1/8/2019 Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com EMI Test System (EMI-9KA/EMI-9KB) Content Table Name Model Characteristic Frequency=9KHZ-30MHz; Used for electronic ballast, CFL & LED lighting industry and others electronic industry. More than 1,000 EMI Receiver units sold in illumination industry, energy meter and small household appliance industry, most of famous company have used EMI Test System (EMI-9KA) this test instrument, such as Philips, Panasonic, GE Lighting and etc. Artificial Network Power Attenuator Isolation Transformer Equipped with artificial network can test disturbance voltage of mains terminal. 20dB Attenuate, it is an auxiliary accessory to help test 2pcs of 500W isolation transformer and 1pc of 1000W isolation transformer Testing frequency=9KHZ-300MHZ and this system is used to test Conductive Emission EMI Receiver according to newly CISPR 15/CISPR-16. The instrument complies with newly European and USA standard, test result reliable and accurate. Artificial EMI Test System (EMI-9KB) Network Power Attenuator Equipped with artificial network can test disturbance voltage of mains terminal. 20dB Attenuate ,it is an auxiliary accessory to help test EMI receiver equipped with coupling Coupling /decoupling network is equivalent to test Decoupling radiated electromagnetic disturbance of Network electric lighting appliance with frequency from 30M-300mHz Isolation Transformer 2pcs of 500W isolation transformer and 1pc of 1000W isolation transformer -Page 1 - Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com The EMI-9KA/B systems both have three Isolated power supplies. The Artificial Network Power and Coupling Decoupling Network must work with the Isolated power supply. EMI-9KB is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which make sure high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPR16-1, GB17743, FCC, EN55015 and EN55022 Detection frequency range: EMI-9KB is 9kHz~300MHz and EMI-9KA is 9KHz~30MHz Frequency stability: 1x 10-6 Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz; (30MHz~300MHz) 5kHz Test Tolerance: ±2 dB Measure and Detection method: PK,QP and AV range from 20dBμV to 140dBμV Test time: setting by customers Frequency scanning step length: 20Hz~2M Sweep bandwidth: 200Hz; 9kHz; 120kHz The Next Pages are the Test Report for EMI-9KA/B: -Page 2 - Lisun Electronics Inc. www.Lisungroup.com Sales@Lisungroup.com Tel:+86(21)51083341 EMI Test Report Project No.: Standard: Test Item: Temp./Hum.(%RH): EUT: Model: Note: 130 dBuV 1 GB17743 4 5 7 8 10 Limit: Power Source: Date: Time: Manufacturer: Test By: QP 3 2016/07/15 13/49/31 Philips Lighting 9 AV 120 110 100 90 80 70 60 50 40 30 20 10 0.009 NO. 0.1 1 10 Frequency Reading Correct Result Limit Margin (MHz) (dBuV) Factor(dB) (dBuV) (dBuV) (dB) 30MHz Remark Lisun Electronics Inc. www.Lisungroup.com Sales@Lisungroup.com Tel:+86(21)51083341 EMI Test Report Project No.: Standard: Test Item: Temp./Hum.(%RH): EUT: Model: Note: 130 dBuV RT201010001 EN55015 CDN-M2 LED25W-A01 25℃/65% LED Street Lamp Lisun EMI-9KB Limit: QP Power Source: Date: Time: Manufacturer: Test By: Isolation Transformer 2017-3-23 6:54:9 Philips Lighting AV 120 110 100 90 80 70 60 50 40 30 20 10 30 NO. 100 300MHz Frequency Reading Correct Result Limit Margin (MHz) (dBuV) Factor(dB) (dBuV) (dBuV) (dB) Remark