Brochure Energy Dispersive X-ray Fluorescence Spectrometer (EDX-2) Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Chapter 1 Summarize Chapter 区分) Lisun Electronics(大标题,居中小三加粗,尽量在新一页,用 Inc. (USA) Add:Operating 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. 1. instruction (一级标题,左对齐小四加粗) Email: Sales@Lisungroup.com According to the requirements of CIE, IESNA and the National’s standard, this system is a multi-measurement mode spectrophotometer system which can realize LisunA-α China Factory B-β, and C-γ etc through rotating lamps and lanterns. Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 It test Spatial, light intensity distribution curves on any cross section (can be shown Email: Engineering@Lisungroup.com under the rectangular coordinate system or polar coordinate system), spatial iso-intensity curve. (正文,段首顶格左对齐 10 号,段落之间空行) Introduction Lead in CFL & LED Test Instruments Rev. 1/16/2019 Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com The quotation includes the following items: For the purpose of restricting the pollution caused by the dispose of electronic and electrical products, the RoHS or Lead Free directive was announced by EU on Feb 13th of 2003 and became effective on Jul 1st of 2007. Lisun Group developed an high accuracy EDXRF spectrometer. The EDX-2 can fully meet the RoHS test requirements -Page 1 - Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com Part 1 Specification: Nondestructive measurement, no chemical and physical damage on measured object High accuracy which can be similar as chemical test Detect and analyze more than 75 chemical elements from Sulfur to Uranium, test Range: 2ppm~99.99% Measure the details for the 5 restricted elements in RoHS Directive: Cd/Pb/Hg/Cr/Br) esting time: 60~300s Adopt world-famous electrical cooled detector, reliable and stable, energy resolving power is less than 160eV X-ray tube voltage: 5~50kV; Tube current: 50~1000uA High definition camera built-in; USA made high pressure module built-in; Light enhancement system SNR design enhanced, quick test circuit and precise numbering system Multi-function software and multi-substrate effect calibration module built-in The system includes a PC and printer which have already installed the English software Part 2 Installation 2.1 Structure 2.1.1 Front view: ①: Cover ②: Strut Bar ③: Control Column ④: Sample Hole ⑤: Body -Page 2 - Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com ⑥: Power ⑦: Indicator ⑧: Detector ⑨: Collimator 2.1.2 Rear view ①: Fan ②: RS-232C port ③: USB port ④: Outlet 2.2 Installation 2.2.1 Preparation for operation. The RoHS test system needs enough space as follows: -Page 3 - Lisun Electronics Inc. Sales@Lisungroup.com 2.2.2 Connection -Page 4 - www.Lisungroup.com Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com Part 3 Operation 3.1 RoHS testing process START CHECK CONNECTION FIRST TEST NO PREHEAT 30min YES SET 200s NO TESTING TIME 200s YES INITIALIZATION? YES CHOOSE CURVE CHOOSE COLILIMATOR TEST START TO PRINT YES PRINT NO END -Page 5 - NO PUT IN SILVER TO CALIBRATE Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com 3.2 Preparation Before switching on EDX, check all the connections. Then power on PC, printer, EDX-2, and preheat 30min.Initiallize EDX-2, put in silver slice, choose 1# collimator, click” ”, system calibrate automatically. 3.3 Sample test 1. According element needed of sample, choose the right rohs testing mode (choose the wrong mode lead to a bad accuracy) 2. Put in matching collimator (choose the wrong collimator lead to a bad accuracy) 3. Choose testing time, 200s is recommended(too long or too short lead a bad accuracy) 4. Put the unknown sample into the testing bed, observe the cross of camera is in the center of unknown sample, or you can adjust it by moving the sample and control column. 5. Close the cover, the protective light on 6. Click “Start” 7. After testing, you can save the data and name 8. If need to print, click ”Total analysis report”, then go to ”report info setting” Notice: EDX-2 need to calibrate after switching on every time Wrong mode and collimator and too short RoHS test time lead to additional error. Too small unknown sample or not in the center of he cross of camera lead error. Next page is the test report -Page 6 - Lisun Electronics Inc. www.Lisungroup.com Tel:+86(21)51083342 ANALYSIS REPORT FOR RoHS REGULATIONS Sample Name:CFL Tube Sample Source:TUV Analysis institution:Lisun EDX-2 Analysis Duration:200s Tube Current(uA):400uA Sample Batch:No.1250 Operator:Jacky Jiang Analysis Date:2014-03-14 Tube Voltage(KV): 45kV Work Curve Used:PE Y-计计 4500 4360 4000 3500 3000 2500 2000 1500 1000 Hg As BrPb 2048 500 Cd 0 0 Element As Hg Pb Br Cd 200 400 600 Intensity 0.0020 0.0014 0.0054 0.1454 0.0024 800 1000 1200 Content(ppm) 28.02 25.26 94.04 538.68 121.97 1400 1600 Limitation 1000 1000 1000 1000 100 1800 2000 Results X-通通 Pass Pass Pass Pass False Note:1)ND stands for contents not larger than 2ppm. 2)All Data are based on sample surface analysis with this X-ray fluorescence Instrument. 3)The Data for Cr&Br are the summation contents respective, their above-limitation doesn't mean the same thing with VI-valence Cr,PBB and PBDE.