TRANSACTIONS OF THE INSTITUTE OF FLUID-FLOW MACHINERY No. 136, 2017, 3546 ukasz Zªoty∗ and Damian Pasikowski Study of characteristic curves of rotodynamic pumps working as turbines Institute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Politechniki 1, 00-661 Warsaw, Poland Abstract Centrifugal pumps working in reverse mode can be a good alternative for conventional water turbines. Prediction of the pumps as turbine characteristic curve is still complicated due to the lack of information provided by the producers and rare research focusing on this subject. In some cases of pumping systems it is important to estimate the operating point in turbine mode basing on pump test data. In this paper the pump characteristics in turbine mode for ten pumps with a specic speed between 10261 were compared and analyzed. The formulas used to predict the best performance point and characteristics of pump as turbine was reviewed. Own formulas for calculating optimum points of pump in the turbine mode was proposed. Keywords: Pump as turbine (PAT); Rotodynamic pump; Hydraulic power; Recovery turbine Nomenclature BEP best eciency point D g H Ns n ngt Q impeller diameter, m 2 gravitational acceleration, m/s head, m pump specic speed rotational speed, rpm turbine specic speed 3 ow rate, m /h ∗ Corresponding author. E-mail address: lukasz.zloty@itc.pw.edu.pl ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 36 . Zªoty and D. Pasikowski Greek symbols αp βt γ , αt , βp η κ pump dimensionless specic speed turbine dimensionless specic speed dimensionless parameters from [2] equation 8,9,10 respectively hydraulic eciency relationship between pump eciency at BEP point and pump ϕ ψ dimensionless head dimensionless ow specic speed acc. [3] Subscripts h p t 1 hydraulic eciency refers to pump refers to pump in turbine mode Intruoduction The idea of using pumps as turbines is very attractive and can be a good alternative to standard solutions applying water turbines. Rotodynamic pumps have relatively simple construction what provides long failure-free operation and accessible maintenance. They are readily available due to the multitude of manufacturers and pumps suppliers. Economically it has been found that a pump operating as a turbine in the range of 1 to 500 kW allows for the return on investment costs over two years or less, which is considerably shorter than in a conventional turbine [1]. Choosing the proper pump as a turbine (PAT) requires knowledge of the pump characteristics working in turbine (reverse) mode. It is a demanding task because these characteristic curves are not usually supplied with the pump or did not made available by the producers. In addition the prediction methods of reverse mode are often focusing on the best eciency point (BEP) and gives many dierent results. Manufacturers of such equipment often do not have turbine test benches focusing on determining the typical ow characteristics of the pump. Many researchers, including Stepano [4], Childs [16], Sharma [6], Wong [19], Williams [9], Alatorre-Frenk [5], show the equations used to predict pump performance as a turbine. The purpose of these formulas is to calculate the BEP of a pump turbine mode using the characteristics of the pumps provided by the manufacturer. 2 Prediction method overview This section provides a brief description of several prediction methods available in the literature. These formulas will be used to compare estimate accuracy of turbine mode characteristics. ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 Study of characteristic curves of rotodynamic pumps. . . 37 Childs [16] claimed that the best turbine and pump eciency for the same machine are practically equal. Equations of the head, H , and the ow rate, Q, are reported by: Qt 1 = , Qp ηp (1) Ht 1 = . Hp ηp (2) Stephano [4] has proposed a method that uses pump eciency. Gives the ratios of turbine and pump head and ow to the hydraulic eciency of the pump. He states that the ow of a pump working as a turbine at the same speed would have the following values: Qt 1 , (3) = Qp ηhp 1 Ht = 2 . Hp ηhp (4) Because hydraulic eciency is not usually known, the following simplication has been introduced: √ ηhp = ηp . (5) Taking into account this simplication we get 1 Qt =√ , Qp ηp (6) Ht 1 = . Hp ηp (7) Sharma [6] developed a prediction method that also uses coecients depending on the eciency of the pump: Qt 1 = 0.8 , (8) Qp ηp Ht 1 = 1.2 . Hp ηp (9) Alatorre-Frenk [5] for calculating head, ow and eciency in reverse mode, used eciency, head and ow in pump mode. Formulas are as follows: 0.85ηp5 + 0.385 Qt = , Qp 2ηp9.5 + 0.205 ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. (10) 136(2017) 3546 38 . Zªoty and D. Pasikowski Ht 1 = , 5 Hp 0.85ηp + 0.385 (11) ηt = ηp − 0.03 . (12) Schmiedl [14] presented forecasting method uses the estimated value of hydraulic eciency. In this method the eciency of the hydraulic system is calculated from the following relation: q ηhp = (13) ηp0.5 ηt0.5 . The equations for the BEP in Schmiedl method are as follows: Qt 2.4 = −1.5 + 2 , Qp ηhp (14) Ht 2.5 = −1.4 + . Hp ηhp (15) Grover [17] has presented the following equations (but they are) limited in their application to specic speeds in the range of 10 < Ns < 50: Qt = 2.379 − 0.0264nqt , Qp (16) Ht = 2.693 − 0.0229nqt . Hp (17) Hergt [18] calculates the head and ow in reverse mode using the specic speed PAT in BEP: Qt 1.6 = 1.3 − , (18) Qp nqt − 5 Ht 6 = 1.3 − . Hp nqt − 3 (19) Derakhaskan and Nourbakhsh [2] formulated a PAT of the BEP prediction method using pump BEP point based on experimental research of four pumps. Their recommend to predictions pumps with the specic speed Ns < 60: γ = 0.0233αp + 0.6464 , αt = 0.9413αp − 0.6045 , (20) βt = 0.849βp − 1.2376 . Nautiyal and his team [3], who relied on their own research and on other researcher's data, performed an analysis to estimate the relationship between pump ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 Study of characteristic curves of rotodynamic pumps. . . 39 eciency at optimal point and specic speed. They received the following relationship: ηp − 0.212 κ= . (21) lnNs Using κ , they determined the relationship between the ow and head in pump and turbine mode: Qt = 30.303κ − 3.424 , (22) Qp Ht = 41.667κ − 5.042 . Hp 3 (23) Proposed formula Using the collected data for BEPs in pump and turbine mode, a graph of the dimensionless turbine ow relative to the pump ow and the dimensionless head in turbine mode relative to the head in the pump mode was drawn. It is worth noting that the points of dimensional ow are linear approximation points are presented in Fig. 1. The equation for this straight line can be represented as follows: ϕt = 1.990.5 ϕp + 2−6.48 . Figure 1. Dimensionless ow at BEP in pump and turbine mode (24) ϕ see Eq. (27). ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 40 . Zªoty and D. Pasikowski Approximation points presented in Fig. 2 is a linear function also proposed for the prediction head coecient (25) ψt = 4.740.5 ψp − 5.720.5 . Figure 2. Dimensionless head at BEP in pump and turbine mode, ψ see Eq. (28). The following equation gives satisfying results for Ns < 90, which works better for higher specic speeds: ψ = 1.50.5 ψp + 1.340.5 . 4 (26) Diagram Using the research [7,8] conducted to prepare complete characteristic of rotodynamic pump. The results are used to draw diagrams for machine working in pump mode and reverse mode. The results are shown dimensionless parameters: • dimensionless ow coecient ψ= Q , nD3 (27) ϕ= gH . n2 D 2 (28) • dimensionless head coecient Characteristic curves of pump and turbine mode for dierent specic speed from 10 to 261 are presented in Figs. 3 and 4. This diagrams and experiment data was applied to comparison formulas to PAT's characteristic curves by means of proposed formula. ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 Study of characteristic curves of rotodynamic pumps. . . Figure 3. Dimensionless head curves for Figure 4. Dimensionless head curves for 5 41 Ns = 1024. Ns = 33261. Comparison prediction method A comparison of the turbine best performance prediction methods is presented in Tab. 1. It shows the percentage estimating mistake of the ow coecient, ϕt , and the head coecient, ψt , obtained from the predictions in relation to the experimental data. Graphic illustrations of errors are shown in Figs. 5 and 6. By looking at the results of comparisons, it can be stated that there is no explicit method of forecasting the operating point on the whole range of pumps with dierent speed ratings. The Childs method [16] has given satisfactory results in predicting the ow value. ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 9 10 15.1 17.5 19.3 19.9 23.1 24 24.5 30.4 36.4 39.7 42 46.4 55 61.3 64 79.1 94.4 105 209 261 [10] [7] [11] [7] [12] [8] [8] [7] [13] [14] [13] [13] [12] [13] [8] [13] [11] [13] [13] [8] [8] [8] Pump Source Ns 0.069 0.035 0.054 0.063 0.047 0.084 0.088 0.088 0.117 0.122 0.185 0.200 0.190 0.275 0.380 0.414 0.527 0.480 0.400 0.470 0.500 0.910 ϕt 30.91 15.42 7.03 8.59 7.70 7.61 8.70 7.67 11.17 6.86 8.00 6.70 7.84 7.60 6.93 5.75 5.37 4.88 3.82 4.34 2.01 2.34 ψt Experimental 0.7 -15.9 -19.2 -18.2 19.0 -26.4 20.6 -19.3 -32.1 -13.4 -12.8 -12.9 -7.4 -0.5 -10.9 -10.8 25.6 -6.0 -3.9 4.2 -3.1 -18.9 ϕt [%] -16.4 -17.3 20.5 -6.9 -5.3 -3.0 12.1 -17.7 -41.8 -13.6 -21.9 -16.2 -31.3 -16.0 -17.0 -4.6 56.1 -13.3 -21.1 -23.1 -34.0 -100.0 ψt [%] Childs -27.4 -41.1 -30.3 -32.9 -0.3 -36.7 -13.1 -31.2 -40.0 -24.5 -24.8 -19.7 -18.5 -13.2 -22.8 -24.3 -7.5 -13.9 -12.5 -15.3 -21.9 -33.1 -16.4 -17.3 20.5 -6.9 -5.3 -3.0 12.1 -17.7 -41.8 -13.6 -21.9 -16.2 -31.3 -16.0 -17.0 -4.6 56.1 -13.3 -21.1 -23.1 -34.0 -45.2 Stepano ψt [%] ϕt [%] -11.7 -27.0 -23.8 -24.5 10.9 -30.7 5.8 -24.3 -35.4 -18.1 -17.8 -15.7 -12.0 -5.8 -15.9 -16.4 11.1 -9.2 -7.4 -4.1 -11.1 -24.9 ϕt [%] -4.7 -4.6 27.9 -0.8 -1.7 -3.1 -27.8 -12.3 -38.8 -8.7 -17.1 -13.4 -27.8 -11.3 -12.1 1.9 76.4 -10.2 -18.1 -16.4 -28.1 -40.8 ψ =t [%] Sharma 12.1 -12.9 18.9 5.5 56.2 1.0 10.9 2.4 -8.6 3.7 -8.1 -1.4 -8.8 -12.7 -39.8 ϕt [%] 8.2 -0.2 110.2 43.7 49.8 60.7 26.2 28.4 -3.2 31.2 8.1 27.1 -7.8 4.4 -12.1 ψt [%] Grover Table 1. Comparison of prediction method accuracy. -47.2 -86.0 -13.1 -66.4 27.9 -16.4 -3.3 -6.4 -51.3 95.9 -11.6 -23.2 -4.3 6.0 -24.3 -7.1 -14.5 77.7 20.9 25.7 34.8 5.5 7.3 -19.1 9.6 -9.0 7.7 -21.3 -9.4 -19.9 Derakhshan ψt [%] ϕt [%] -9.8 -9.6 5.4 -4.6 41.8 -9.8 1.2 -4.4 -16.0 2.0 -2.5 10.2 7.2 10.8 -2.8 -6.6 -1.7 13.8 15.4 -0.6 -8.9 -20.9 -13.1 -27.3 60.9 8.6 13.8 24.9 -0.6 -0.7 -22.6 8.2 -3.4 19.3 -14.6 8.0 1.0 7.9 40.0 9.2 10.4 -11.2 10.1 -4.9 Prop. formula ψt [%] ϕt [%] 42 . Zªoty and D. Pasikowski ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 Study of characteristic curves of rotodynamic pumps. . . 43 Figure 5. Variation between used prediction method of the ow coecient for dierent calculation methods. Figure 6. Variation between used prediction method of the head coecient for dierent calculation methods. For several pumps, predictions calculated with formulas are signicantly higher than for others. For pump with Ns = 15.1, the disproportion for lift height ψt is from 20% to 110%. Similarly, the situation looks for pump with Ns = 64 for which the predictive dierence is from 39% to 99% above the test outcome. For pump with Ns = 19.3, the ow coecient, ϕt , for the formulas proposed by Alaterre-Frenk [5], Grover [7], Derakhshan [2] and given in this work has been considerably inated. It is dicult to determine which of the formulas works best for the specic range because two closely related pump identities, e.g., Ns = 24, and 24.5, have very dierent deviations from the same prediction formula. Comparison of the average estimation mistake magnitude for all comparable pumps are in [15], selected are presented in Tab. 2. This table provides a quick view of which of the formulas generates the smallest variation between turbine mode parameters. The proposed formulas give satisfactory results for the entire range of pumps being ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 44 . Zªoty and D. Pasikowski compared. The Childs and Grover methods provide a relatively good result only for the ow coecient. The BEP gives the image of work under xed conditions. As known, the operating conditions may vary depending on the pressure or ow available. Another important issue is the possibility of estimating values in terms other than denominated working conditions. Table 2. Comparison of accuracy of the prediction methods. Prediction method Average estimation of mistake magnitude ϕt [%] ψt [%] Childs 14.0 22.8 Stepano 23.9 20.9 Sharma 17.2 17.9 Alaterre-Frenk 17.0 16.8 Grover 13.5 25.7 Derakhshan 26.7 15.1 Proposed formula 10.8 13.8 The best solution is to have a complete ow characteristic of pump. In paper [5], a method has been proposed for converting the entire turbine characteristics to the substitution of the best turbine mode. The use of the proposed formula for calculation BEP and turbine characteristic for three cases curves is presented in Fig. 7. Figure 7. Dimensional ow characteristics of pump reverse mode for the measured data and the predictions Derakhaskan and Nourbakhsh. Formula for the BEP prediction from this paper. ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 Study of characteristic curves of rotodynamic pumps. . . 6 45 Conclusions Various methods of predicting the best turbine mode are discussed. Their own formulas have also been proposed, which can be used to predict the operating point in reverse mode. Presented formulas, they have been checked to what extent they agree with the measurement data. In comparison, thirty pumps were considered for which the specic speed dierence was in the range of Ns = 9261. The comparison shows that the available formulas are characterized by large discrepancies. Also, it is dicult to pinpoint the range of specic speed for which the formula works best, because for similar specic speed the formulas give significant dierences. Other parameters, such as eciency, rotational velocity, or ow channel geometry, would have to be considered in order to indicate a particular formula. For the whole range of pumps compared, the smallest average estimation mistake was obtained based on the formulas proposed in this article. This indicates the possibility of using them in case of selection of the turbine pump in a satisfactory part of the cases. However, it should be borne in mind that the formula may be subject to a large error for specic pumps. If the application requires thorough knowledge of the course of the characteristics and knowledge of the ow parameters of the machine, it would be necessary to carry out experimental research. A good solution to this problem of pump selection and technology development would be to identify suitable for generating energy from rotodynamic pumps available on the market by dening performance characteristics for the pump series and establishing the general relationship between parameters in pump and turbine modes. Pump manufacturers should be interested in this area as it would allow them to expand the market for their products. Received in September 2017 References Theoretical, numerical and experimental prediction of pump as turbine performance. Renew. Energ. 48(2012), 507513. Derakhshan S., Nourbakhsh A.: Experimental study of characteristic curves of centrifugal pumps working as turbines in dierent specic speeds. Exp. Therm. Fluid Sci. 32(2008), [1] Yang S.-S., Derakhshan S.,. Kong F.-Y.: [2] 800807. [3] Nautiyal H., Varun K., Thakur A.: Nepal: J. Water Energ. Environ. CFD analysis on pumps working as turbines. 6(2010), Hydro 3537. Centrifugal and Axial Flow Pumps. Wiley, NewYork 1957. Alatorre-Frenk C. Cost minimization in micro hydro systems using pumps-as-turbines. PhD [4] Stepano A.J.: [5] thesis, Univercity of Warwick, Warwick 1994. ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 46 . Zªoty and D. Pasikowski [6] Sharma, K. Small Hydroelectric Project-Use of Centrifugal Pumps as Turbines ; Techn. Rep., Kirloskar Electric Co., Bangalore 1985. [7] Szymczyk J., Kara±kiewicz K.: Application of the pump characteristics at PAT operation. Instal, O±rodek Informacji Technika instalacyjna w budownictwie 368(2015), 12 , 4649 (in Polish). et al.: Experimental investigation of the complete characteristics of rotodynamic pumps. FEDSM2009, ASME 2009 Fluids Engineering Division Summer Meeting, Colorado, [8] Ayder E. August 26, 2009. The turbine performance of centrifugal pumps: a comparison of prediction methods. IN: Proc. Inst. Mech. Eng. A J. Power Energy 208(1994), 15966. Shi G., et al.: Conversion relation of centrifugal pumps as hydraulic turbines based on the amplication coecient. Adv. Mech. Eng. 9(2017), 3, 18. Frosina E., Buono D., Senatore A.: A performance prediction method for pumps as turbines (PAT) using a computational uid dynamics (CFD) modeling approach. Energies 10(2017). Huang S., et al.: Performance prediction of a centrifugal pump as turbine using rotor-volute matching principle. Renew. Energ. 108(2017), 6471. Singh P.: Optimization of Internal Hydraulics and of System Design for Pumps as Turbines with Field Implementation and Evaluation. PhD thesis, University of Karlsruhe, Karlsruhe [9] Williams A.A.: [10] [11] [12] [13] 2005. Serien-Kreiselpumpen im Turbinen Betrieb. Pumpentagung, Karlsruhe 1988. D.: Study of Characteristic Curves Centrifugal Pumps Working as Turbines. [14] Schmiedl E.: [15] Pasikowski MSc thesis, Warsaw University of Technology, Warszawa 2017. [16] Childs S.M.: Convert pumps to turbines and recover HP. Petroleum Rener [17] Grover K.M.: 41(1962), Hydro Carbon Processing and 10, 173-174. Conversion of pumps to turbines. GSA Inter Corp., Katonah, New York 1980. [18] Lewinsky K.: H.-P. pumpen als turbinen fur kleinkraftwerke. Wasserwirtschaft 77(1987), 10, 53137. [19] Wong W.: Application of centrifugal pumps for powers generation. World Pump (1987), 348381. [20] Szymczyk J., Kara±kiewicz K.: Fluid-Flow Mach. 130(2015), The modeling of centrifugal pump transients. 8392. ISSN 0079-3205 Trans. Inst. Fluid-Flow Mach. 136(2017) 3546 Trans. Inst.