We'd like to show you notifications for the latest news and updates. NO THANKS ALLOW Cleaning Validation Protocol Posted By: Pharmaceutical Guidanace on: November 06, 2016 In: Cleaning Validation(CV), Validation & Quali cation No Comments CONTENTS S. No. Topic 1.0 Protocol Preparation and Approval Sheet 2.0 Objective 3.0 Scope 4.0 Responsibility 5.0 Validation Team 6.0 Abbreviations and De nitions 7.0 Cleaning Validation Approach 7.1 Selection of Products 7.2 Selection of Equipments 7.3 Type Cleaning after every ve consecutive batches of the same product 8.0 Pre – Cleaning Validation Requirements 9.0 Precautions and Instructions 10.0 Acceptance Criteria 10.1 Product Residue Contamination 10.2 Cleaning agent residue contamination 10.3 Microbial Contamination 11.0 Cleaning Validation Programme 11.1 Selection of Cleaning Procedure 11.2 Water Quality 11.3 Selection of Analytical Method 11.4 Analytical Method Validation 11.5 Sampling Plan, Type of Sampling and Selection of Sampling method 11.6 Evaluation of Cleaning Procedure 11.7 Analytical Testing Procedure 11.8 Cleaning Veri cation 11.9 Ongoing Monitoring Page No. 11.10 Ancillary Equipment 11.11 Cleaning of Manufacturing Area 12.0 Hold Time Studies 12.1 Equipment Holding Studies Prior to Cleaning 12.2 Cleaned Equipment Hold Time Studies 13.0 Training 14.0 Revalidation 15.0 Deviations and Investigations 16.0 Cleaning Validation Report 17.0 List of Annexures / Formats Attached 18.0 Reference Documents We'd like to show you notifications for the latest news and updates. NO THANKS ALLOW Protocol Preparation and Approval Sheet Prepared By Department Name Designation Signature Date Quality Assurance Reviewed By Department Name Designation Signature Date Production Quality Control Quality Assurance Approved By Name Designation Signature Date Head Operation Head QC Head QA Objective To evaluate the capability of cleaning procedure Type A in removing the drug residue and microbiological bio burden on equipment within established acceptance criteria, through the validation of cleaning procedures. To establish su cient documented evidence to assure that, cleaning procedures can repeatedly and reproducibly remove residue of the subjected product and / or cleaning agent i.e. Sodium Lauryl Sulphate (wherever applicable) – within established acceptance limit. The acceptance limit is maximum allowable quantity of product residue and / or cleaning agent, which does not a ect quality and safety of the subsequent product to be manufactured, by using same equipment and facility. To establish acceptable time limit for storage of cleaned equipment, utensils and components after cleaning (Cleaned Equipment Hold Time Study). Equipments are not expected to be free from all microorganisms. The objective shall be to demonstrate that there is no microbial proliferation in equipments during storage. Scope This protocol is applicable for validation of cleaning procedure to be followed in Tablet & Capsule section of Pharmaceutical Formulation Plant . Demonstrate that the cleaning procedure shall perform consistently according to predetermined acceptance criteria. We'd like to show you notifications for the latest No unauthorized or unrecorded modi cations have been taken place. news and updates. Cleaning validation shall be performed after Type A cleaning. After satisfactory visual inspection only, the equipment shall be allowed for sampling. NO THANKS ALLOW Swab samples and Rinse samples shall be collected to verify the presence of active residue content and Microbiological bio burden as per given sampling plan. Samples should be taken from pre-de ned locations as mentioned in this protocol. All Sampling and testing reports have been made available. All precautions and instructions have been followed. Three runs of cleaning are required to prove that the process has been validated. Responsibility Department Responsibilities Responsible for ensuring the overall validation of cleaning methods, used to clean the process equipment, utensils and areas. These responsibilities for cleaning validation include: Preparation, Review and approval of Cleaning Validation Protocols, Reports and Cleaning Validation Summary Reports. The approval of SOPs, STPs, GTPs and Cleaning Method Validation Protocols & Reports. Quality Assurance : Execution of Cleaning Validation Activities. Sampling during cleaning validation. Handling of Deviations. Training of team involved in cleaning validation. Compile and review of Report Verifying the cleaning activities Responsible for ensuring the validation of cleaning methods, followed within this department. These responsibilities for cleaning validation include: Review of Cleaning Validation Protocols, Reports and Cleaning Validation Summary Reports. The preparation and approval of general operating and cleaning procedures (SOPs). Production : Execution of Cleaning Validation Activities Provision of personnel for the cleaning of equipment during validation studies. Initiation of Deviations Training on equipment and area cleaning SOPs. Checking of Cleaning activities Responsible for ensuring the validation of analytical methods used to analyze cleaning validation samples. These responsibilities for cleaning validation include: Preparation and Approval of Cleaning Method Validation Protocols and Reports. Review and Approval of Cleaning Validation Protocols, Reports and Cleaning Validation Summary Reports. Quality Control : The approval of SOPs, STPs and GTPs. Analysis of cleaning validation samples and report submission Initiation of Deviations Training responsibilities Department Responsibilities We'd like to show you notifications for the latest news and updates. Responsible for ensuring the Calculation of equipment contact surface area. NO THANKS Engineering : ALLOW Equipment, components, utensils and area drawings. Drawings and Quali cation documents of supporting utilities. Validation Team Validation team shall comprise of the representatives from following functions: Quality Assurance Production Quality Control Engineering Abbreviations and De nitions API: : Active Pharmaceutical Ingredient LOD : Limit of Detection LOQ : Limit of Quantitation MACO : Maximum Allowable Carry Over MDD : Maximum Daily Dose SLS : Sodium Lauryl Sulphate BS : Batch size SOP : Standard operating Procedure GTP : General Test Procedure ID.No : Identi cation number STP : Standard Test Procedure TD : Therapeutic Dose ppm : Parts per million Kg : Kilogram mg : Milli gram cfu : Colony forming unit cGMP : Current Good manufacturing Practice ss : Stainless Steel ml : Milli litre µg : Micro gram Fig : Figure cm : Centimetre cm : Square Centimetre Clean : 2 The implementation of procedures to render a piece of equipment, or a system, free of adulterants and contaminants. The process of providingWe'd documented evidence that the cleaning like to show you notifications for themethods latest and updates. employed within a facilitynews consistently controls potential carryover of product Cleaning Validation : (including intermediates and impurities), cleaning agents and extraneous material into subsequent product to a level, is below predetermined NOwhich THANKS ALLOW levels. Drug active, excipient, degradant, processing aid, cleaning agent, bio burden or Contaminant : foreign matter that, at a high enough level remaining after cleaning may potentially contaminate the equipment surfaces or the next product. Dedicated Equipment/ Accessories : Equipment Train : Manual Cleaning : Objectionable Equipment/Accessories only used for the manufacture of one product or one related product line. Series of individual pieces of equipment linked together for a given process which may be cleaned individually or as a process train. A cleaning procedure requiring operator performed critical steps (e.g., scrubbing with a brush or rinsing with a hose) Any organisms that can cause infections, when the drug product is used as Micro organisms : Protocol : A document with agreed upon set of standards and tests. Rinse : To clean or treat an equipment as part of a cleaning procedure. Swab : An absorptive device used to remove a sample from a surface. Visually Clean : Absence of visible contaminants. Worst case : Lacs : directed or any organism capable of growth in the drug product. Worst case is those conditions within normal parameters most likely to give failure. This is an Indian system of counting and 10 lacs is equal to 1 million. Cleaning Validation Approach This speci c protocol shall be applicable to Tablet and Capsule section only. Due to complexity of manufacturing and packing of multiple products using same equipment a Bracketing approach shall be applied to prioritize Cleaning Validation Program based on scienti c rationale. The approach evaluates overall cleaning requirement of the product range and concentrates the validation e ort to develop Worst Case situation, where common cleaning procedures are followed for similar type (Operating Principle and Capacity) of equipment. The Worst Case is considered on the basis of following factors: Physical characteristic i.e. Solubility, Cleanability Therapeutic Dose of the Product Concentration of Active Ingredient Equipment combination (Equipment Train) In this bracketing approach cleaning validation of each equipment train shall be performed based upon the worst-case product selected for that equipment train. A Matrix of products with the details of active ingredient, therapeutic category, strength, maximum daily dose (mg & No. of dosage units), and batch size (kg & Lacs) and solubility shall be prepared. A Matrix of Equipment combination with the details of equipment name, I.D. No., area, capacity, contact surface area, equipment usage and preferred rinse volume for sampling shall be prepared. On the basis of matrix of Products and Equipments, Worst Case situation (Product to Product Change Over) shall be derived. The rationale for each Worst Case shall be justi ed scienti cally. Rationale for the residue limit established should be scienti c, logical and based upon knowledge of the material. The limits should be practical, achievable and veri able. Type cleaning shall be done in the following situations: Product to Product change over We'd like to show you notifications for the latest After every ve consecutive batches of the same product news and updates. Production of same products in descending potency After any major changes of product contact parts NO THANKS ALLOW Receiving of new equipment Selection of Products Refer Annexure 1 (Product matrix and selection or worst case products) for Products manufactured in tablet and capsule section . Selection of Equipments Refer Annexure 2 (Equipment matrix) for equipments used in manufacturing of tablet and capsule section. Cleaning of equipments that are not within the equipment train If any equipment is not used in the production of worst case products (i.e. not covered under equipment train), e ectiveness of cleaning shall be accomplished by deliberately contaminating the equipment. Type A Cleaning after every ve consecutive batches of the same product Type A cleaning after every ve consecutive batches of the same product shall be assessed by charging accelerated stability th studies and results derived from Impurity pro le for 5 batch & microbiological analysis data for all ve batches. Pre Cleaning Validation Requirements The cleaning shall be done by following the SOP for cleaning of equipment. Three successful runs of batches or di erent strength of the same product shall be considered for completion of cleaning validation activity. Sampling shall be done from all the pre-decided locations and as per surface area mentioned. The equipment’s used for manufacturing shall be as per list of equipment’s. The critical parts of equipment, which are di cult to clean, shall be considered for sampling. Critical in-process control shall be evaluated with respect to the laid down speci cation. Swab/ Rinse samples shall be analyzed as per laid down test procedures and comply with respect to the predetermined speci cations. Pre Cleaning Validation requirements viz. Product details, Batch Numbers taken for validation, Equipments used for manufacturing & SOPs for cleaning and Approval status of applicable documents (STPs, GTPs, and Analytical Method Validation protocols & reports e.t.c.). Precaution and Instructions Uncleaned and cleaned equipments shall be transferred to cleaning area in closed condition. (If the cleaning is not done in the same area). All the steps shall be followed by same sequence mentioned in the respective cleaning SOP / Cleaning validation test record. Cleaning Agent (SLS) shall be used wherever applicable. Visual inspection shall be performed after completion of cleaning and drying of equipments. After satisfactory observation, the equipment shall be allowed for sampling. A successful visual inspection is a pre requisite for sampling. If any residue is detected during the visual inspection, this represents a deviation which must be processed according to a pre de ned procedure and the equipment shall be cleaned again until visual inspection is satisfactory. The rst step of the sampling sequence is the test for microbiological contamination to prevent false positive results from preceding tests. The second step of the sampling sequence is the swab test. The last step of the sampling sequence is the rinse sampling. For cleaned equipment hold time studies the cleaned equipments must be kept completely closed (covered with cling lm). Acceptance Criteria Product Residue Contamination The rationale for selecting limits of carryover of product residue shall be logically based on the materials involved. The limits should be practical, achievable and veri able. On the basis of following criteria acceptance limits i.e. Maximum Allowable Carry Over (MACO) shall be established: Dose Criteria (or safety based criteria or medical limit criteria) As per this criteria not more 0.001 dose of any product shall appear in the maximum daily dose of the next product The following equation shall be used for the calculation of MACO from previous product (let be a product A to next product We'd like to show you notifications for the latest news and updates. (let be a product B) TDX SF X BS Maximum Allowable Carry Over (mg per batch) = ——————— NO THANKS ALLOW MDD Where, TD: Single therapeutic dose (smallest strength based on number of mg of active ingredient) of previous product (Product A) SF: Safety Factor (0.001) BS: Batch size of the next product (product B) i.e. Minimum Batch Size MDD:Maximum Daily Dose; milligram of dosage units of the product B taken per day 10 ppm criteria As per this criterion, not more than 10 ppm of any product will appear in another product. The following equation is used to calculate the limit of product A if the next product on the production schedule is product B. Maximum Allowable Carry Over (mg per batch) = 0.00001(mg/mg) X BS in mg Where, 0.00001 mg of product A per 1000000mg of the product B BS: Batch size of the next product in mg. On the basis of dose criteria and 10 ppm criteria the MACO limit shall be calculated and the dose criteria limit shall be selected as a Worst Case condition. After establishing MACO (with minimum value) the swab limits and / or rinse limits shall be established with respect to total product contact surface area and total rinse volume respectively. MACO X 100 2 Swab Limit (drug in mg per 100 cm swabbed area) = ———————TS Where, 2 100: Sampled swab area (100 cm ) 2 TS: Total product contact surface area (cm ) MACO Rinse Limit (drug in mg per liter) = ————————————Total Volume used in liters Visual Inspection Visual inspection shall be performed after completion of cleaning. After satisfactory observation, the equipment shall be allowed for sampling. Cleaning Agent Residue Contamination The rationale for selecting limits of carryover of cleaning agent (sodium lauryl sulphate) residue shall be logically based on the material involved. The limits should be practical, achievable and veri able. On the basis of following criteria acceptance limits i.e. Maximum Allowable Carry Over (MACO) shall be established: In case of Cleaning agent (SLS) residue, MACO shall be calculated as follows as per medical limit criteria: LD50 (g/kg) X 70(kg a person) No Observable E ect Level = ————————————— We'd like to show you notifications for the latest news and updates. Conversion Factor (1000) NO THANKS ALLOW From the NOEL number a MACO can then be calculated according to NOEL X MBS Maximum Allowable Carry Over (mg per batch) = ————————SF X MDD Where, LD50: LD50 value (lethal dose) of the cleaning agent i.e. Sodium lauryl sulphate SF: Safety Factor (10000) BS: Batch size of the next product (product B) i.e. Minimum Batch Size MDD: Maximum Daily Dose; milligram of dosage units of the product Btaken per day Based on the Bracketing approach the following products were selected for Worst case as per 0.001 dosage criteria and the limits shall be followed as below: Type of Dosage Form Tablet“ Tablet“ Un coated Film Coated Hard Gelatine Capsule Tablet Uncoated Worst case Product API Location / Area Limit as per Dose Criteria Limit as per 10 ppm Criteria Swab Limit Limit for validation -Swab Limit (including Recovery factor) Limit for validation -Rinse Limit Limit Of Quanti cation Make the computerised report after getting swab/rinse sample Chemical and micro analysis and hold time study. Combine the rinse water sample and swab sample results and to determine the total carryover. Cleaning agent limits shall be followed as below Cleaning Agent Location/Area Worst case product API Next product MACO limit Rinse Limit for validation Microbial Contamination Swab samples shall be collected from product contact surface area immediately after completion of cleaning activities and We'd like to show you notifications for the latest satisfactory visual inspection. For cleaned equipment hold time studies shall be collected as per speci ed intervals news samples and updates. (0 days, 3 days, 7 days, 10 days & 14 days). The limits for the microbiological bio burden criteria for product contact surface are presented below. NO THANKS ALLOW 2 Total Aerobic Microbial Count Swab sampling (cfu / 25 cm ) Limit NMT 100 During this study, identify all of the micro-organisms isolated so that the data obtained may serve as the baseline for a trend analysis program. Once validation e orts are complete and results have established the e ectiveness of the cleaning and sanitization procedures, a good microbiological control program must be implemented. Cleaned equipment hold time studies shall be performed in one area with covering of each type of equipment. Total Aerobic Microbial Count for manufacturing area shall be studied after completion of cleaning, by contact plate technique (Only for reference purpose only). Cleaning Validation Programme Selection of Cleaning Procedure There are following three types of cleaning methods utilized in the drug product manufacturing facilities. Clean-In-Place (CIP) Cleaning of the equipment is performed in place without disassembling and transferring to the Washing area which is also de ned as In Situ Cleaning. Cleaning process may be controlled manually or by an automated program. Clean-Out-Of-Place (COP) Cleaning of disassembled equipment is performed in a central washing machine. The washing machine also requires validation such as the temperature, ultrasonic activity, cycle time, cleaning operation sequence, water quantity, and detergent quantity dispensed etc. Manual Cleaning Di cult to clean. Most extensive and elaborate cleaning procedures are required. A high quality and extensive training program is required. Tablet and Capsule section has designed with manual cleaning operations. Wherever, CIP or automated cleaning feature is designed for the Equipment, those methods of cleaning shall be validated in conjunction with manual cleaning. The risk involve in manual cleaning processes is taken care of with following factors: Designing and Construction of washing area with segregation of used equipment cleaning with treated water, nal cleaning with puri ed water and wiping with clean non-shredding cloth /drying with compressed air. Adequate protection (covering with cling lm) and storage facility of cleaned equipment. Detailed SOPs for cleaning. Training/Quali cation of cleaning operators. Water Quality Water to be used for the cleaning of manufacturing equipment is treated water (Potable water) and Puri ed water to be used for nal rinsing of equipment. Selection Of Analytical Method The development and validation of analytical procedures for detection of product residue in cleaning validation sample requires the selection of appropriate analytical methods. A speci c method must be selected carefully for detection of product residue; a non-speci c analytical method may lead to false analytical results. During validation of the cleaning procedure, the analytical methods used should be able to speci cally quantify concentrations of all compounds of interest that may be present in samples. Speci c method shall be employed during cleaning validation and for subsequent cleaning veri cation or ongoing We'd like to show you notifications for the latest monitoring of cleaning, non- speci c methods shall be employed. news and updates. Analytical Method Validation NO THANKS ALLOW Any instrumental analytical procedures used to analyze cleaning validation samples need to be speci ed and su ciently sensitive to determine the low levels of residues typically found in samples. The methods used to analyze samples that allow the equipment to be released for manufacture of another product shall be validated to ensure that it meets following requirements. Speci city Limit of Detection (LOD) Limit of Quantitation (LOQ) Linearity Precision Recovery of drug from spiked swabs Recovery of drug from spiked SS plates, Te on sheets and other product contact materials. Range Stability of Analytical Solution Robustness Sampling Plan, Type of Sampling and Selection of Sampling Method Sampling shall be done as per sampling plan. Samples shall be taken. The e ectiveness of cleaning procedures shall be evaluated by following methods. Visual Inspection: Visual inspection of equipment for cleanliness immediately before use is required by the cGMP regulations. Swab sampling: The area to be sampled should be selected using judgement about which areas are hard to clean. Rinse Sampling: Collection of rinse samples should consider hard to access locations and volume. Evaluation Of Cleaning Procedures The e ectiveness of cleaning procedures shall be evaluated by following sampling methods. Visual Inspection Visual cleanliness criteria shall be the primary criteria for the cleaning of equipment. Easy and preferred pre-sampling criteria Qualitative and subjective. Visual inspection shall be performed after completion of cleaning. After satisfactory observation, the equipment shall be allowed for sampling. Visual cleanliness can be evaluated by visual inspection of the equipment after cleaning as per the test record Organoleptic techniques (i.e. visual, smell, touch) shall be used as a component of the cleaning program and additionally as one of the tests useful for the validation of the cleaning procedure. Ensure that equipment visual inspection shall be done at a distance of less than 25 cm and lighting level should be more than 325 lux. Swab sampling Wet the cotton tip of swab with puri ed water and squeeze the cotton tip by pressing gently against the wall of test tube to remove excess of puri ed water. 2 2 Swab sample shall be collected from 10 x 10 cm (100 cm ). Selection of sample position shall be based on di cult to clean equipment surface area. Before collection of swab sample visual inspection of the equipment shall be done to check the cleanliness. For cleaning validation swab sample shall be collected for chemical/ microbiological analysis from the locations speci ed as per the sampling locations. Most of the equipments shall be swabbed for at least 5 locations, depends on equipment size, accessibility and compliancity. Strongly preferred method, as some residues may need a mechanical or physical action to remove from the surface. 2 Swab the surface of equipment for 100 cm area rmly and swab horizontally with one side of the swab and vertically with other side of the swab (10 strokes on each side). Do not rub the surface in to & fro motion. We'd like to show you notifications for the latest news and updates. Put the swab into a clean tube and transfer to the quality control laboratory in a dry state, Pour 10 ml of sample medium (which was speci ed in method validation protocol) to the test tubeALLOW and extract the NO THANKS residual drug from the swab in sample medium by sonication of the test tube for about 5 minutes. Take out the swab from the test solution, squeeze the cotton tip of the swab against the wall of the test tube and discard the swab. Shake the test tube to make the homogenous solution. This solution shall be used as test solution and shall be analysed for drug swabbed, from the equipment surface. Sample for the microbial analysis shall be taken by microbiologist as per procedure mentioned in Protocol for validation of techniques used for bio burden analysis in cleaning validation. Rinse Sample (Wherever applicable) Rinse sample shall be collected from the hard-to-access locations of the equipments. Equipment surface shall be rinsed with the given quantity of rinse volume with puri ed water and the sample shall be collected from the rinsate. After collecting the sample visually inspects the sample it shall be clear, colourless and free from particulate matter. This solution shall be used as test solution and shall be analysed for the presence of the previous product . However results of rinse sample alone can not be used for the evaluation of cleaning validation results and its conclusion. Samples shall be mentioned Batch Number, Name of product, Equipment Id.No, Sampling Location, Sampled by and Date. The samples shall be stored at 2-8°C up to testing. Analytical Testing Procedure Follow the procedure  for the analysis of cleaning validation samples to determine drug residues. Cleaning Veri cation Cleaning veri cation approach will be applied for the unique condition where the product being manufactured for the rst time is not tting / does not exit in the established product / equipment matrix, until cleaning procedure has been validated or it is one time activity / event the product will not be manufactured in the same manner on the commercial scale equipment. Cleaning veri cation approach will be also applied while introducing/ replacing the any equipment of the train, after appropriate evaluation. Based on evaluation, veri cation will be performed if required for particular equipment until cleaning procedure has been validated. Cleaning veri cation will establish / demonstrate the proper removal of target product residue and microbial load by which it will not alter the safety, identity, strength, purity and/ or quality of subsequent drug product being manufactured on the same equipment. Following criteria shall be adopted: Selection of swabbing position based on the experience for di cult to clean location of equipment or history for worst-case sampling. Method adopted shall be quali ed for the sensitivity and swab recovery. Cleaning veri cation approach will be also applied while introducing/ replacing the any equipment of the train, after appropriate evaluation. Based on evaluation, veri cation will be performed if required for particular equipment until cleaning procedure has been validated. Ongoing Monitoring Once validated, it is advisable to recon rm cleaning e ectiveness from time to time. For manual processes this is essential until su cient data has been generated to con rm the reproducibility of the cleaning procedure. Ongoing monitoring shall be performed with de ned criteria on validation report to verify / monitor the cleaning process is able to con rm the ongoing appropriateness of the training program as well as operator ability to perform the cleaning process. Ancillary Equipment Ancillary equipment is utilized along with the main equipment illustrated in the equipment list. They aid in the manufacturing process in terms of product transfer. Examples of ancillary equipment are SS scoops, SS spatulas, SS beakers / measuring cylinders and SS containers etc. Cleaning validation will be established for ancillary equipment. Cleaning of Manufacturing Area (Non contact surface area -reference purpose only) We'd like to show you notifications for the latest news and updates. Cleaning of manufacturing area shall be studied (for Reference purpose only) through this protocol to evaluate the area cleanliness level. The limits shall be taken as given in product contact surface area and the nal conclusion shall be drawn after completion of cleaning validation. NO THANKS ALLOW Hold Time Studies The objective of hold time study is for establishing time limit between equipment cleaning and reuses it to ensure that the equipment remains clean till the next use. Equipment Holding Studies prior to cleaning The interval between the end of production and the beginning of the cleaning process shall be established through equipment holding studies prior to cleaning. It is important to consider the e ect that weekends, holidays and delays might have on the cleaning schedule. For example, a piece of equipment that is utilized rst thing in the morning may sit, contaminated with product, until the second shift starts. Having the product dry on equipment, therefore, considered as worst case. An equipments shall be kept ideally for 72 hours at production area, prior to cleaning and consider as worst case. Cleaned Equipment Hold Time Studies (Microbiological Study only) Concerns relative to microbial control are lessened in the production of non-sterile products but are still important. Practices which minimize the potential for contamination by objectionable organism are common in the manufacture of non-sterile formulations. To establish the expiry of cleaning in view of microbiology, equipment shall be kept ideally after cleaning for 336 hours (14 days) and microbiological swab shall be taken and analysed at di erent intervals (0 hour, 36 hours, 168 hours, 240 hours and 336 hours). This will be considering as worst case and microbial load should remain well within limit. Training Operator training is critical, especially for manual cleaning. During cycle development, operators should be trained in the requirements of the evolving or existing SOPs. Proper training consists of understanding the SOP, apprenticeship with quali ed, trained operators and review to ensure that the training is successful. The e ective training or quali cation of the operators may be con rmed by monitoring of the equipment after cleaning, including, where necessary, analytical testing for residuals. It is important not only that operator training occur, but also that the training be well documented. Operators should be retrained each time a cleaning procedure is changed and the new training must be documents, just as in the case of a change to a manufacturing procedure. Revalidation The cleaning process of speci ed equipment for the speci c product shall be revalidated in one or more of following cases Change of formulation procedures or quality of pharmaceutical ingredients. Major changes of process parameters. Change in facilities Equipment changes Changes in cleaning procedure On appearance of new ndings based on current knowledge. Batch size change. Implementation of these changes shall be carried out as per change control system. Deviations and Investigations Any deviation observed during cleaning validation shall be recorded and investigated If the observed deviation does not have any major impact on the validation the nal conclusion shall be provided. If the observed deviation has major impact on the validation, deviation shall be reported to the concerned department for the corrective action and validation activity shall be redone. We'd like to show you notifications for the latest news and updates. Cleaning Validation Report NO THANKS ALLOW Based on the outcome from this validation study, a report shall be prepared by Quality Assurance. The validation report shall be reviewed and then approved by all functional heads of all the concerned departments. References Validation Master Plan 21 Code of Federal Regulations, parts 210 & 211 US FDA Guide to Inspections Validation of Cleaning Process PIC/S Recommendations on Validation Master Plan, Installation and Operational Quali cations, Non-Sterile Process Validation & Cleaning Validation APIC Guide on Aspects of Cleaning Validation in Active Pharmaceutical Ingredient PDA Technical Report No. 29:Points to Consider for Cleaning Validation Ira R. Berry, Robert A. Nash, Pharmaceutical Process Validation Lucia Clontz, ˜Microbial Limit and Bio burden Tests Validation Approaches and Global Requirements Batch Manufacturing Records Batch Packing Records Analytical methods Validation Protocols & Reports