BUILDING DIVISION 437 N Wasatch Drive Layton, UT 84041 www.laytoncity.org Phone: 801-336-3760 Fax: 801-336-3789 RESIDENTIAL - SOLAR PANEL PLAN SUBMITTAL CHECKLIST PLAN SUBMITAL CHECK LIST – The following is a list of items required for residential SOLAR PANEL plan submittal. The Planning Department or the Plans Examiner may require additional information to complete their review. Please review and check each box indicating its completion and sign the bottom of the page. Missing information may cause a delay in plan review approval. 1. BUILDING PERMIT APPLICATION –Apply online at www.laytoncity.org and include the following: All required information completed including owner, contractor and subcontractor, DOPL license and project valuation. 2. SITE PLAN (PLOT PLAN): North Arrow Location of Home (aerial view if desired) Diagram of all PV system components on house and/or property including: main meter, module array(s), electrical panel(s), inverter(s), pass through box(s), AC disconnect, 3’ wide clearance around edges of roof, fire fighter pathways 3. ENGINEER’S REPORT: Engineer’s report providing structural analysis of the roof system and its ability to handle the additional weight, etc. (Required for all permits regardless) 4. ONE-LINE DIAGRAM(S) showing the following information: 5. Type of PV system (single inverter, micro inverter or AC module system) Main Meter and size (100AMP, 200AMP, etc.) Meter upgrade required? Disconnect type and rating Inverter type and rating Number and layout of modules and how they are connected together (in series or in parallel) Types and sizes of electrical wiring and conduit Ratings of all fuses or breakers Location and size of all grounding MODULES / INVERTERS / COMBINER BOXES / ROOF SYSTEM: Provide manufacturer’s specification sheets for modules, inverters and combiner boxes, mounting systems, etc. Note whether home has roof rafters (type and size) or engineered trusses 6. ELECTRICAL PANEL: Provide actual photos of: A) Service panel location; B) Service panel with inside cover removed; C) Panel rating info. Show any other boxes to be mounted and interconnected to electrical panel 7. OTHER SYSTEM COMPONENTS: Provide information on all other components to be used in the system, their UL listing and installation information, etc. 8. SAFETY AND WARNING LABELS: List specific Warning Labels to be used (show samples) for disconnects, electrical boxes, conduit, breakers, etc. Show location(s) where warning labels are to be posted (may be shown on one-line diagram) 9. PLUMBING / MECHANICAL VENTS: Show location of any and all plumbing and mechanical roof vents. NOTE: No solar panel may be installed over the top of a vent. All vents must be relocated by a licenses plumber or mechanical contractor. I hereby acknowledge that I have reviewed the above checklist and have included each required item with my plan submittal. Project Address: ____________________________________________________________________________________________ Signature: ____________________________________ Printed Name: ______________________________ Company: ____________________________________ Phone: ____________________________________ ShareCD\Building Division\Docs_Handouts\RES SOLAR PANEL PLAN SUBMITTAL CKLST 012216 Date: _________ Revised 01/22/16