Meditech Multiparameter Monitor

12 inch high brightness colorful TFT Display

Analysis of real time ST segment and arrhythmia

Powerful data review for graphic, tabular trends and alarms review

Standard parameter of ECG, NIBP, RESP, digital SPO2, TEMP and PR Maxi 96 hour graphic
and tabular trend with data storage

Big font, oxyCRG, Full-lead ECG interface to meet different requirement;

LAN or wireless network connection as central monitoring system;

Digital SPO2 enables effective examination in case of active patient, low infusion and
interference from electric knife

Protection against high-frequency electro tome and defibrillation effects
Optional configuration:
IBP, ECTO2 and recorder (printer), drug dose calculation and OXYCRG
ECG
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; avR; avL; avF; V
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: ± 1bpm or ± 1%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage in isolation
against electrosurgical and defibrillation
S-T detection: YES, Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable
Pulse Oximetry
SPO2 Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%;
1% to 69% range: ±5%;
Method: Dual wavelength LED
NIBP (Non-invasive Blood Pressure)
Technique: Oscillometric during inflation
Range: Adult/Pediatric: 40 to 240 mmHg
Neonate: 10 to 150 mmHg
Measurement Cycle: < 40 sec. typical
Automatic Measurement
Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode: 5 minutes of continuous readings
Max. Allowable Cuff
Pressure: Adult: 300mmHg
Pediatric: 240 mmHg;
Neonate: 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading,
Heart (Pulse) Rate
Range: 30 to 250 bpm
Accuracy: ±2 bpm or ±3%, whichever is greater
Respiration Rate
Method Impedance between R-F(RA-LL)
Differential Input Impedance
>2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range:
0 – 2.5 KΩ
Bandwidth
0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped
0 ~ 150 rpm
Resolution 1 rpm
Accuracy
2 rpm
Apean Alarm 10 ~ 40 S
TEMP
Measuring and Alarm Range 0 ~ 50 C
Resolution
0.1 C
Accuracy
0.1 C
Actualization interval
about 1 Sec.
Average Time Constant < 10 Sec.
Printer (optional)
Type: Thermal printer
Paper Speed: 6.25, 12.5, 25 mm/sec
Power Requirements
Voltage: 110-240 V AC; 50 Hz
Power Consumption: 8 Watts, typical
Battery: 1 sealed lithium battery
Battery Life: 8 hours, typical
Recharge Time: 4 hours, typical
Interface & Display
Keys: 9; membrane activated
Rotary Knob: Push and rotate; 24 steps/turn
Screen: 15 inch active color TFT
Resolution: 800 x 600 pixels
Wave forms: 8 maximum
Sweep Speed: 6.25, 12.5, 25 mm/s
Languages: English
Meditech Equipment Co., Ltd (Meditech Group)
Address: Nanjing Road No.100, Qingdao, Shandong Province, P. R. China
Tel: 86-532-85832673 85820563
Fax: 86-532-85832155
Email: sales@meditech.cn
0123
Web: www.meditech.com.cn
Download