Currently, a large percentage of Meditech business is performed for the healthcare market – assembling everything from patient heart monitors to cancer diagnostic devices. We thoroughly understand the critical nature of the medical industry, and provide thorough documentation with traceability to all of our medical customers, ensuring the medical PCB assembly will exceed manufacturing requirements and customer satisfaction demands. Medical PCB Assembly Due to our continued growth in the medical and bio-medical markets, Meditech has invested in certifications that are necessary for circuit board assembly manufacturing. We are ISO13485:2003 certified and compliant to FDA CRF820 part 21, guaranteeing that we meet the necessary requirements for medical PCB assembly. Our software management system, Cogiscan’s Track, Trace and Control (TTC) System, that is used in our production floor is incredibly beneficial to our medical PCB assembly customers. This system allows us to provide detailed traceability, all the way to the reference designator, on enrolled products. Additionally, the TTC Program further illustrates our commitment to transparency and our emphasis on full traceability. We would genuinely love the opportunity to assist in building your medical product – please contact us to learn more about our healthcare services. We offer world-class circuit board assembly and electro-mechanical box build services to the medical industry. Products Range Digital SpO2 Module www.meditech.com.cn oem@meditech.cn Analog SpO2 Module Multi Parameter Monitor NIBP Module Side stream EtCO2 module Digital SpO2 Module Analog SpO2 Module Model: MD100 Model: MD200 Range Pulse rate: 30 ~ 250 bpm SpO2: 0 ~ 100% Weak perfusion 0.1% Resolution(1SD) Pulse rate: (30~250BPM) +2bpm or -2bpm Normal +3bpm or -3bpm Motion or low perfusion SpO2: (70~100%) +2% or -2% Normal +3% or -3%Motion or low perfusion Below 70% Not specified Environmental Requirements Operating temperature: 0~45 °C Storage temperature: -20~60 °C Operating Humidity:30~95% Storage Humidity:10~100% Operating Altitude:-500~5000m Storage Altitude:-500~10000m Par. Min. Typ. Max. 5V +4.75V +5V +5.25V Ripple --- --- 100mVp-p Current --- 20mA --- Serial transmission logic capacity: TTL/RS232 Serial Port Standards IEC60601-1: SPO2: BF-type IEC60601-1-27: 1994: EN865 ANSI/AAMI SP10: 1992: EN12470-4:2001 Sensor : Only digital sensor can be used for this module SPO2 Measuring range: 50 -100% SPO2 Measurement accuracy: ±2 @ 50-100% SPO2 Less than 50% have not been defined Pulse rate Measuring range : 30-235 times / min Measurement accuracy: Greater than ±2 times / min or ±2% Bar chart: 0-8 Environmental Requirements Operating temperature: 0~45 °C Storage temperature: -20~60 °C Operating Humidity:30~95% Storage Humidity:10~100% Operating Altitude:-500~5000m Storage Altitude:-500~10000m Serial transmission logic capacity: TTL/RS232 Serial Port Security Oxygen saturation: BF – type Power Requirements Operating voltage: 5V ±0.1V DC Power: 40mA Environmental conditions Operating temperature: 5-50℃ Storage temperature : -20℃ - +70 ℃ Relative humidity : 0-85% (non-condensing) Size 40 x 52 x 10mm Standards IEC60601-1: SPO2: BF-type IEC60601-1-27: 1994: EN865 ANSI/AAMI SP10: 1992: EN12470-4:2001 Sensor: BCI sensor can be used for this module. Multi Parameter Module Model: MD01 HR Adult 15 ~ 300 BPM Neo/Ped 15 ~ 350 BPM Accuracy ± 1% or ± 1bpm choose the greater one Resolution 1BPM RESP rate Range and Accuracy Adult 7~120BrPM Neo/Ped ~150 BrPM Resolution 1 BrPM Accuracy ±2 BrPM NIBP Adult Mode SYS 40 ~ 270mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 235 mmHg stalic state pressure range 0~300mmHg Stalic state pressure accuracy ±3mmHg blood pressure accuracy: Maximum Mean error ±5mmHg; Maximum Standard deviation ±8mmHg SPO2 Range 0 ~ 100 % Resolution 1 % Accuracy 70~100%:±2 DIGIT 0% ~ 69% unspecified Pulse Rate Range 20~300bpm Resolution 1BPM Accuracy ±3bpm TEMP Range 0 ~ 50 °C Resolution 0.1°C Accuracy ±0.1°C(not include sensor error) IBP Accuracy: ± 1mmHg or ± 2%,take the greater one (not include sensor error) Power supply: Request of exterior power supply input voltage 12V DC(±10%),0.5A,lines wave <100mv Power consume:stalic state < 2W,work < 6W. Isolated: 4000VAC Leak current <0.5mA Work Environment Operating temperature: 0 ~ 55°C Storage temperature: -20 ~ 65 °C Operating Humidity: 15% ~ 95 % (no coagulate) Storage Humidity: 10% ~ 95 %(no coagulate) Size: 120mm x 100mm x 25mm Weight: < 300 g(not include accessories NIBP Module Model: MD-IBP2 Measuring range: Adult: 30 to 255 mmHg systolic blood pressure An average of 20 to 235 mmHg pressure 15 to 220 mmHg diastolic blood pressure Pulse rate of 30 to 240 times / min Newborn: 30 to 135 mmHg systolic blood pressure An average of 20 to 125 mmHg pressure 15 to 110 mmHg diastolic blood pressure Pulse Rate of 40 to 240 times / min Measurement time: Adults: up to more than 120 seconds; Newborn: up to more than 90 seconds; Restriction on software over voltage: Adult: Less than 290mmHg; Newborns: no more than 145mmHg; Protection on hardware over voltage: Adult: 300 ±10 mmHg; Newborn: 150 ±4 mmHg; Measuring principle Oscillometry Deflation approach: ladder Deflated The initial inflation pressure value: Adult: 150 mmHg; Newborn: 70 mmHg; Sensor zero reset: Prior to each measurement Resolution: 1 mmHg Measurement accuracy: Maximum average deviation: no more than ± 5 mmHg; maximum standard deviation: less than 8 mmHg; Pressure accuracy instructions: ± 3 mmHg Leakage: less than 6 mmHg Per minute; Electrical performance: Voltage: 12 VDC (adapt to the corresponding valve), 5 VDC Quiescent current: 80 mA Measurement current: 200 mA Environment: inflated current: 600mA Operating Temperature: 0 to 55 Celsius degrees Storage Temperature: -20 to 65 Celsius degrees Humidity Range: 0 to 95%, noncondenser Operation Altitude: -500 m to 4600 meters Life Span: can operate 100,000 blood pressure measurements Size 12.6 cm x 6.8 cm x 2.8 cm Weight: 180 g Mainstream EtCO2 Module Model: MD-ET2 Sensor Operating Principle Energy Emitting Device Energy Detecting Device CO2 Range CO2 Accuracy Intelligent design can wipe off the excursion from temperature, pressure and inconsistent component. It allows wrong power supply, humidity in the pipeline. Great capacity to ensure that any provision of about 50 sets of stock TTL or RS232 can be choice by customer. Breath Rate Dimensions Weight Operating Temperature Range Shipping / Storage Temperature Range Automatic Offset Calibration Input Voltage Interface Pneumatics Power Consumption Warm-up Time Response Time: Detector System Infrared Spectroscopy Proprietary High Efficiency IR Source Frequency Stable Thermopile 0% to 20% ± 2 mmHg @ < 5.0% CO2 (at BTPS) < 5% of reading @ 5.0% to 13% CO2 (at BTPS) < 10% of reading @ 13% to 20.0% CO2 (at BTPS) 2-150 BPM 77mm*52mm*28mm < 3.0 ounces (< 76 grams) 5° C to 50° C -40° C to 70° C Time and temperature based, as well as on-demand 5.00 Volts (± 5%) Highly configurable serial digital interface(TTL/RS232), CO2 and barometric waveform data, Breath Detect Algorithm data On-board aspiration pump and flow controller Configurable aspiration flows to 250 ml/min (± 10%) 480mW (typical with pump on) 1200mW (extreme status) 10 seconds 28 mSec (typical) 200mSec (typical) (Dependent Upon Implementation, Pneumatics and Water Separation Technique)