PrevaLED® Compact Z2 LED Module

advertisement
www.osram-americas.com
PrevaLED® Compact Z2 LED Module
Key Features & Benefits
—— High efficacy up to 140 LPW
—— Zhaga Book 4 compliant for easier
luminaire integration
—— Design flexibilty through 4 lumen
packages (2500, 4000, 6000,
8000) and 2 CCTs (4000K and
5700K)
—— Long life: up to 100,000 hours (L80)
minimizing maintenance frequency
so long as max Tc is below 80°C
—— 5 year system warranty when
paired with OPTOTRONIC® Constant
Current LED power supplies
—— Dimmable down to 20%
—— Fully compatible with widely available fixture mounting dimensions,
heat sinks, reflectors and other
accessories
Extremely compact, high performance, Zhaga Book 4 compliant light
engine ideal for industrial high bay, low bay applications, and outdoor
fixtures with IP54 rating. The module is available in four lumen packages
(2500, 4000, 6000 and 8000), two CCTs (4000K and 5700K) and offers
dimming down to 20%. Due to the module's Zhaga Book 4 compliance,
it is fully compatible with widely available heat sinks, fixture mounting
holes, reflectors and other accessories.
The PrevaLED Compact Z2 is optimally paired with OPTOTRONIC
constant current LED power supplies, this system offers a five
year warranty.
Product Offering
LumensCCT
25004000K
40004000K
6000
4000K, 5700K
8000
4000K, 5700K
CRI
70
70
70
70, 80
Application Information
Applications
—— Industrial low/high bay
—— Street and area lighting
LED423 1-15
Specifications and Certifications
The OSRAM PrevaLED Compact Z2 is UL8750 Recognized for
the US and Canada (UL File # E346592)
Specification Data
Catalog #
Type
Project
Comments
Prepared by
Ordering Information
Initial
Light
Nominal
Operating
Item Ordering Lumens
Emitting
Color Wattage
Current (mA)
Case
Number
Abbreviation
(lm)
Surface (LES)
Temperature
CRI
(W)
Typical
Max
LPW
Quantity
Greater than 70 CRI
79352
PL-CP-Z2-2500-740
2500
42mm x 10.5mm
4000K
70
18
410
451
140
20
79353
PL-CP-Z2-4000-740
4000
43mm x 10.5mm
4000K
70
29
425
467
138
20
79354
PL-CP-Z2-6000-740
6000
60mm x 15mm
4000K
70
45
505
555
134
20
79355
PL-CP-Z2-6000-757
6000
60mm x 15mm
5700K
70
45
505
555
134
20
79357
PL-CP-Z2-8000-757
8000
60mm x 15mm
5700K
70
60
490
539
134
20
Greater than 80 CRI
79356
PL-CP-Z2-8000-840
8000
60 mm x 15 mm
4000K
80
77
635
698
104
20
Ordering Guide
PL
-CP -Z
2
-2500
-
Sub-brand
Type
Zhaga Compliant
2nd Generation
Lumen Output
PL = PrevaLED ®
Compact
7
CRI
>70
40
Color Temperature
40 = 4000K
Accessories
Item Number
79359
Ordering Description
OT Cable 60CM
Description
Cable to connect to OPTOTRONIC power supplies
Items to be used with
All Item Numbers
Power Supply Information
OPTOTRONIC® Outdoor Programmable
OT50W
OT100WOT180W
All Item Numbers
•
•
•
Minimum and Maximum Ratings
ParameterValues
Operating Temperature at Tc Point
-30 to 50°C (-22 to 122°F)
Storage Temperature -40 to 80°C (-40 to 176°F)
Assembly Diagram
2500 & 4000 Lumen products
6000 & 8000 Lumen products
0.3(7)
1.1(29)
1.5(39)
1.4(36)
1.8(46)
0.3(7)
0.8(21)
3.7(95)
Dimensions: in [mm]
1.2(30)
4.3(110)
Wiring Diagram
LED+
BLACK
WHITE
LINE
LEDPRG/NTC/LT2
NEUTRAL
DIM+
DIM-
RED
BLUE
ORANGE
PURPLE
GRAY
Safety Information
WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT
POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES.
Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well
as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property
damage and/or product malfunction.
1. T he LED module itself and all its components shall not be subjected to mechanical stress and assembly must not damage or destroy conducting paths
on the circuit board.
2. O
bserve correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product, incorrect polarity may lead to emission of red
or no light.)
3. Ensure the power supply is of adequate power to operate the total load.
4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module.
(For more information, reference document # LED093 ESD Protection for LED Systems.)
5. Installation
of LED modules shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to
perform installations.
6. Modules may be hot to the touch. Use caution when handling.
7. D
amage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the user’s responsibility to ensure adequate heat sink
and protection against corrosive agents such as moisture, condensation and other harmful elements.
Warranty
OSRAM LED products are covered by our LED Module, OPTOTRONIC ® Power Supply or Control warranty.
The PrevaLED ® Compact is covered under warranty as long as the temperature at the Tc point does not exceed 80°C; exceeding this temperature will void all warranties.
For additional information or to download the warranty registration form, refer to the latest version of the warranty (LED089) available in the literature section of www.osram-americas.com
Module Warranty - 3 Years
System Warranty - 5 Years
Americas Headquarters
OSRAM SYLVANIA Inc.
100 Endicott Street
Danvers, MA 01923 USA
Phone 1-800-LIGHTBULB (1-800-544-4828)
www.osram-americas.com
OSRAM, PrevaLED, LED CREATING TOMORROW and OPTOTRONIC are registered trademarks of OSRAM GmbH.
Specifications subject to change without notice.
© 2015 OSRAM