www.osram-americas.com PrevaLED® Compact Z2 LED Module Key Features & Benefits —— High efficacy up to 140 LPW —— Zhaga Book 4 compliant for easier luminaire integration —— Design flexibilty through 4 lumen packages (2500, 4000, 6000, 8000) and 2 CCTs (4000K and 5700K) —— Long life: up to 100,000 hours (L80) minimizing maintenance frequency so long as max Tc is below 80°C —— 5 year system warranty when paired with OPTOTRONIC® Constant Current LED power supplies —— Dimmable down to 20% —— Fully compatible with widely available fixture mounting dimensions, heat sinks, reflectors and other accessories Extremely compact, high performance, Zhaga Book 4 compliant light engine ideal for industrial high bay, low bay applications, and outdoor fixtures with IP54 rating. The module is available in four lumen packages (2500, 4000, 6000 and 8000), two CCTs (4000K and 5700K) and offers dimming down to 20%. Due to the module's Zhaga Book 4 compliance, it is fully compatible with widely available heat sinks, fixture mounting holes, reflectors and other accessories. The PrevaLED Compact Z2 is optimally paired with OPTOTRONIC constant current LED power supplies, this system offers a five year warranty. Product Offering LumensCCT 25004000K 40004000K 6000 4000K, 5700K 8000 4000K, 5700K CRI 70 70 70 70, 80 Application Information Applications —— Industrial low/high bay —— Street and area lighting LED423 1-15 Specifications and Certifications The OSRAM PrevaLED Compact Z2 is UL8750 Recognized for the US and Canada (UL File # E346592) Specification Data Catalog # Type Project Comments Prepared by Ordering Information Initial Light Nominal Operating Item Ordering Lumens Emitting Color Wattage Current (mA) Case Number Abbreviation (lm) Surface (LES) Temperature CRI (W) Typical Max LPW Quantity Greater than 70 CRI 79352 PL-CP-Z2-2500-740 2500 42mm x 10.5mm 4000K 70 18 410 451 140 20 79353 PL-CP-Z2-4000-740 4000 43mm x 10.5mm 4000K 70 29 425 467 138 20 79354 PL-CP-Z2-6000-740 6000 60mm x 15mm 4000K 70 45 505 555 134 20 79355 PL-CP-Z2-6000-757 6000 60mm x 15mm 5700K 70 45 505 555 134 20 79357 PL-CP-Z2-8000-757 8000 60mm x 15mm 5700K 70 60 490 539 134 20 Greater than 80 CRI 79356 PL-CP-Z2-8000-840 8000 60 mm x 15 mm 4000K 80 77 635 698 104 20 Ordering Guide PL -CP -Z 2 -2500 - Sub-brand Type Zhaga Compliant 2nd Generation Lumen Output PL = PrevaLED ® Compact 7 CRI >70 40 Color Temperature 40 = 4000K Accessories Item Number 79359 Ordering Description OT Cable 60CM Description Cable to connect to OPTOTRONIC power supplies Items to be used with All Item Numbers Power Supply Information OPTOTRONIC® Outdoor Programmable OT50W OT100WOT180W All Item Numbers • • • Minimum and Maximum Ratings ParameterValues Operating Temperature at Tc Point -30 to 50°C (-22 to 122°F) Storage Temperature -40 to 80°C (-40 to 176°F) Assembly Diagram 2500 & 4000 Lumen products 6000 & 8000 Lumen products 0.3(7) 1.1(29) 1.5(39) 1.4(36) 1.8(46) 0.3(7) 0.8(21) 3.7(95) Dimensions: in [mm] 1.2(30) 4.3(110) Wiring Diagram LED+ BLACK WHITE LINE LEDPRG/NTC/LT2 NEUTRAL DIM+ DIM- RED BLUE ORANGE PURPLE GRAY Safety Information WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES. Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. 1. T he LED module itself and all its components shall not be subjected to mechanical stress and assembly must not damage or destroy conducting paths on the circuit board. 2. O bserve correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product, incorrect polarity may lead to emission of red or no light.) 3. Ensure the power supply is of adequate power to operate the total load. 4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module. (For more information, reference document # LED093 ESD Protection for LED Systems.) 5. Installation of LED modules shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. 6. Modules may be hot to the touch. Use caution when handling. 7. D amage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the user’s responsibility to ensure adequate heat sink and protection against corrosive agents such as moisture, condensation and other harmful elements. Warranty OSRAM LED products are covered by our LED Module, OPTOTRONIC ® Power Supply or Control warranty. The PrevaLED ® Compact is covered under warranty as long as the temperature at the Tc point does not exceed 80°C; exceeding this temperature will void all warranties. For additional information or to download the warranty registration form, refer to the latest version of the warranty (LED089) available in the literature section of www.osram-americas.com Module Warranty - 3 Years System Warranty - 5 Years Americas Headquarters OSRAM SYLVANIA Inc. 100 Endicott Street Danvers, MA 01923 USA Phone 1-800-LIGHTBULB (1-800-544-4828) www.osram-americas.com OSRAM, PrevaLED, LED CREATING TOMORROW and OPTOTRONIC are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. © 2015 OSRAM