AMP-TRAP® A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of medium voltage motors and motor controllers. R-rated fuses are back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-rated fuse size. Amp-trap R-rated fuses are rated 2R to 36R, at 2.4, 4.8, and 7.2kV. 4.8 and 7.2kV fuses are UL Recognized. The 4.8kV (A480R) is available with hookeye tab. The 7.2kV (A072F) series has the same dimensions as the 4.8kV (A480R), allowing smaller 7.2kV equipment or 4.8kV upgrades, and is available as a bolt in version. Features / Benefits ➤ Ferrule mounting for standard clips and interchangeability with other brands of fuses ➤ 7.2kV series has the same dimensions as 4.8kV fuses, allowing compact, higher voltage rated designs ➤ 7.2kV bolt-in design is available for improved design flexiblity HIGHLIGHTS: APPLICATIONS: ➤ ➤ R-Rated ➤ UL Recognized in 4.8 and 7.2kV ratings ➤ Optional hookeye on 4.8kV for non load-break isolation by hookstick Short circuit protection of medium voltage motors and motor controllers DEFINITIONS: R-Rating: An “R” rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating. Back-up type Current-Limiting Fuse: A current limiting fuse which can interrupt any current between it’s rated minimum interrupting current and it’s maximum interrupting current. Backup fuses are not designed or intended to open under overload conditions. E 29 Ratings Approvals ➤ A240R AC: 2R to 36R 2750V, 45kA I.R. Sym. ➤ Ferraz Shawmut Certified A240R @ 2750V, 45kA, Sym. ➤ A480R AC: 2R to 36R 5500V, 63kA I.R. Sym. ➤ UL Recognized Component A480R @ 5080V, 50kA, Sym. A072 @ 7200V, 50kA, Sym. ➤ A072F, A072B AC: 2R to 24R 7200V, 50kA I.R. Sym. UL File #E93367 Spring-Reinforced Clips 228-700-530 (One pair of clips) For 3” Diameter, 2 barrels max. E AMP-TRAP® A240R MEDIUM VOLTAGE FUSES / R-RATED 2.4kV Ferrule Style Indicator Flush with Surface 2 Lb. Force (Tripped) 0.5 (12.7) 3.312 (84.1) 3.312 (84.1) 0.5 (12.7) 3.312 (84.1) 0.5 (12.7) 3 (76) L 3 (76) L 3 (76) L 3 (76) 3 (76) 3 (76) 3 (76) Catalog Numbering System, Ratings, Dimensions, 2.4kV CATALOG NUMBER FIG. STANDARD SIZE A240R2R A240R3R A240R4R A240R6R A240R9R A24OR12R A24OR18R A240R24R A240R36R 2R 3R 4R 6R 9R 12R 18R 24R 36R** CONTINUOUS AMPERE RATING DIM. MINIMUM INTERRUPTING RATING 1 PHASE INTERRUPTING RATING MAXIMUM TESTED at 40ßC L RMS AMPERES RMS Asym RMS Sym 170 250 340 500 760 1000 1500 1950 2900 70kA @ 2750V 45kA @ 2750V A240R A B C 70 100 130 170 200 230 390 450 650 10-7/8 (276mm) * This rating defines the fuse’s long-term thermal capability per ANSI C37. 46-1 and should not be the sole factor for selecting a specific R rating. ** Not recommended for use in fuse clips which grasp only one barrel. E 30 Current in Amperes Total Clearing Time — Current Data, 2.4kV Fuses A240R Current in Amperes Minimum Melting Time — Current Data, 2.4kV Fuses AMP-TRAP® MEDIUM VOLTAGE FUSES / R-RATED A240R, 2400 Volts E Time in Seconds A240R, 2400 Volts Time in Seconds E 31 AMP-TRAP® A240R MEDIUM VOLTAGE FUSES / R-RATED A240R, 2400 Volts Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data, R-Rated Fuses E 32 AMP-TRAP® A480R MEDIUM VOLTAGE FUSES / R-RATED 4.8kV Ferrule Style Blown Fuse Indicator 2Lb. Force (Tripped) 3.312 (84.1) 0.5 (12.7) 3.312 (84.1) L L 3 (76) 3.312 (84.1) 0.5 (12.7) 3 (76) 0.5 (12.7) L 3 (76) 3 (76) 3 (76) 0.34 Dia. Typ. (8) Blown Fuse Indicator (Tripped Position) 1.0 (25.4) 3 (76) E Catalog Numbering System, Ratings, Dimensions, 4.8kV CATALOG NUMBER FIG. CONTINUOUS AMPERE RATING at 40ßC STANDARD SIZE A480R2R-1 A480R3R-1 A480R4R-1 A480R5R-1 A480R6R-1 A480R9R-1 A480R12R-1 A480R18R-1 A480R24R-1 A480R36R-1 2R 3R 4R 5R 6R 9R 12R 18R 24R 36R** 70 100 130 150 170 200 230 390 450 650 2R 3R 4R 5R 6R 9R 12R 18R 24R 70 100 130 150 170 200 230 390 450 DIM. L MINIMUM INTERRUPTING RATING RMS AMPERES 1 PHASE INTERRUPTING RATING UL COMPONENT MAXIMUM RECOGNITION TESTED RMS Asym RMS Sym RMS Asym RMS Sym A480R-1 A B C 190 225 330 400 500 740 955 1440 1910 2810 15-7/8 (403mm) 80kA @ 5080V 50kA @ 5080V 100kA @ 5500V 63kA @ 5500V 80kA @ 5080V 50kA @ 5080V 100kA @ 5500V 63kA @ 5500V A480R-1HE with hookeye A B A480R2R-1HE A480R3R-1HE A480R4R-1HE A480R5R-1HE A480R6R-1HE A480R9R-1HE A480R12R-1HE A480R18R-1HE A480R24R-1HE 190 225 330 400 500 740 955 1440 1910 16-1/8 (410mm) * This rating defines the fuse’s long-term thermal capability per ANSI C37 46-1981 and should not be the sole factor for selecting a specific R rating. ** Not recommended for use in fuse clips which grasp only one barrel. E 33 AMP-TRAP® A480R MEDIUM VOLTAGE FUSES / R-RATED Current in Amperes Total Clearing Time — Current Data, 4.8kV Fuses A480R-1, A480R-1HE, 4800 Volts Time in Seconds Current in Amperes Minimum Melting Time — Current Data, 4.8kV Fuses A480R-1, A480R-1HE, 4800 Volts Time in Seconds E 34 AMP-TRAP® A480R MEDIUM VOLTAGE FUSES / R-RATED A480R-1 and A480R-1HE, 4800 Volts Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data, R-Rated Fuses E Available Current in RMS Symmetrical Amperes E 35 AMP-TRAP® A072F/A072B MEDIUM VOLTAGE FUSES / R-RATED Catalog Numbering System A 0 7 2 F 1 D 0 7.2kV Ferrule & Bolt-in Types R 0 - 12R R Rating Revision/No. Special Features Diameter (D=3") No. of Barrels Style (F=Ferrule , B=Bolt-in Mount) Nominal Voltage Rating (072=7.2kV) Amp-trap Fuse 16.26 (413.1) 3.63 (92.2) Blown Fuse Indicator Extends 0.5 in. (12.7mm) when fuse opens, with 2 lbs. of force at end of travel 0.5 (12.7) 3.312 (84.1) 3 .25 (6.3) 16.26 (413.1) 0.5 (12.7) 7.62 (194) 3 15.88 (403) 15.88 (403) 3.00 (76.2) .25 (6.3) 19.25 (488) 3 (76) 3 (76) .44 x .91 (11 x 23) 3 (76) 17.88 (454.2) Catalog Numbers, Ratings, Dimensions, 7.2kV FIG. CATALOG NUMBER RATING ALLOWABLE CONTINUOUS AMPERE RATING at 40ßC MINIMUM INTERRUPTING RATING RMS AMPERES A072F1DORO-2R A072F1DORO-3R A072F1DORO-4R 2R 3R 4R 70 100 130 190 225 330 A072F1DORO-5R A072F1DORO-6R A072F1DORO-9R A072F1DORO-12R 5R 6R 9R 12R 150 170 200 230 400 500 740 955 A072F2DORO-18R A072F2DORO-24R 18R 24R 390 450 1440 1910 A072B1DARO-2R A072B1DARO-3R A072B1DARO-4R 2R 3R 4R 70 100 130 190 225 330 A072B1DARO-5R A072B1DARO-6R A072B1DARO-9R A072B1DARO-12R 5R 6R 9R 12R 150 170 200 230 400 500 740 955 A072B2DARO-18R A072B2DARO-24R 18R 24R 390 450 1440 1910 1.53 (38.8) 1 PHASE INTERRUPTING RATING UL COMPONENT RECOGNITION RMS Asym. RMS Sym. 80kA @ 7200V 50kA @ 7200V 80kA 50kA @ 7200V @ 7200V Ferrule Type A B Bolt-in Type C D E 36 AMP-TRAP® A072F/A072B MEDIUM VOLTAGE FUSES / R-RATED Current in Amperes Total Clearing Time — Current Data, 7.2kV Fuses A072F and A072B, 7200 Volts E Time in Seconds Current in Amperes Minimum Melting Time — Current Data, 7.2kV Fuses A072F2 and A072B, 7200 Volts Time in Seconds E 37 AMP-TRAP® A072F/A072B MEDIUM VOLTAGE FUSES / R-RATED AO72F and A072B2, 7200 Volts Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data, R-Rated Fuses Available Current in RMS Symmetrical Amperes E 38