Electromyogram Amplifier
Evoked Response Amplifier
The EMG100C amplifies general and skeletal muscle electrical activity. The amplifier functions directly with AcqKnowledge to perform
real-time EMG integration and, as it incorporates fast response and
settling time characteristics, can also be used to monitor single-fiber
EMG, motor unit and peripheral nerve action potentials.
The ERS100C is an extremely low noise differential amplifier that
accurately amplifies very small potentials, such as those associated
with stimulus/response, signal-averaged recordings. Selectable gain
and bandwidth options make the module useful for a variety of
evoked response testing modes. The ERS100C is intended for use in
applications such as auditory brainstem response, startle response,
somatosensory evoked response or nerve conduction velocity
recording.
Specifications
Gain
500, 1000, 2000, 5000
Output Range
±10 V (analog)
Low Pass Filter
500 Hz, 5000 Hz
Specifications
High Pass Filter
1.0 Hz, 10 Hz, 100 Hz
Gain
5000, 10000, 20000, 50000
Notch Filter
50 dB rejection @ 50/60 Hz
Output Range
±10 V (analog)
Noise Voltage
0.2 µ V rms (10 – 500 Hz)
Low Pass Filter
3 kHz, 10 kHz
Z (input)
2 MΩ (Differential) 1000 MΩ (Common mode)
High Pass Filter
1.0 Hz, 20 Hz, 100 Hz
CMRR
110 dB min (50/60 Hz)
Notch Filter
50 dB rejection @ 50/60 Hz
CMIV
±10 V (referenced to amplifier ground)
±1500 VDC (referenced to mains ground)
Noise Voltage
0.5 µ V rms (100 - 3000 Hz)
Z (input)
2 MΩ (Differential) 1000 MΩ (Common mode)
CMRR
110 dB min (50/60 Hz)
CMIV
±10 V (referenced to amplifier ground)
±1500 VDC (referenced to mains ground)
Input Voltage Range:
Gain
500
1000
2000
5000
Catalog No.
BS4 60-1039
Home
Contact
Us
Previous
Next
Vin (mV)
±20
±10
±5
±2
$
Product
Electromyogram Amplifier
Electrooculogram Amplifier
The EOG100C amplifies the corneal-retinal potential. The amplifier
monitors the DC potential on the skin surrounding the eyes, which is
proportional to the degree of eye movement in any direction. The
amplifier output can be switched between normal EOG output and
Derivative of EOG. In Derivative mode, the amplifier outputs the
measured velocity of eye movement, which is useful for saccade and
nystagmus investigations. The amplifier permits DC coupling to electrodes for X/Y graphing of eye movement without discernible decay.
Specifications
Catalog No.
Vin (mV)
±2
±1
±0.5
±0.2
$
BS4 60-1063
Model
545.00 ERS100C
Product
Evoked Response Amplifier
Biopotential 100C Interface Cables
The Biopotential amplifiers connect to
unshielded or shielded electrode leads terminating with Safelead®/Touchproof (1.5mm)
sockets. For best performance, use two shielded
electrode leads and one unshielded electrode
lead per amplifier. See the extensive selection of
electrode leads on page I135. For additional
electrode lead distance, see the Module
Extension Cables on page I139.
Gain
500, 1000, 2000, 5000
Output Selection
Normal, Derivative output
Output Range
± 10 V (analog)
Low Pass Filter
35 Hz, 100 Hz
High Pass Filter
DC, 0.05 Hz
Notch Filter
50 dB rejection @ 50/60 Hz
All Biopotential Amplifier Specifications
Noise Voltage
0.1 µ V rms (0.05 – 35 Hz)
Signal Source
Electrodes (three electrode leads required)
Z (input)
2 MΩ (Differential) 1000 MΩ (Common mode)
Dimensions
4 cm (wide) x 11 cm (deep) x 19 cm (high)
CMRR
110 dB min (50/60 Hz)
Weight
350 g
CMIV
±10 V (referenced to amplifier ground)
±1500 VDC (referenced to mains ground)
For CBL200, see page I138.
Input Voltage Range:
Gain
500
1000
2000
5000
Catalog No.
BS4 60-1040
I109
Model
545.00 EMG100C
Input Voltage Range:
Gain
5000
10000
20000
50000
Vin (mV)
±20
±10
±5
±2
$
Model
545.00 EOG100C
For CBL204, see page I138.
For JUMP100C, see page I139.
Product
Electrooculogram Amplifier
11,000 Specialty Products to Enhance Your Bioresearch
U.S. Toll Free: (800) 272-2775 • Fax: (508) 429-5732 • Online: www.harvardapparatus.com