Data Acquisition Systems - Biopac Previous Next Table of Contents Product Index Search Electromyogram Amplifier Evoked Response Amplifier The EMG100C amplifies general and skeletal muscle electrical activity. The amplifier functions directly with AcqKnowledge to perform real-time EMG integration and, as it incorporates fast response and settling time characteristics, can also be used to monitor single-fiber EMG, motor unit and peripheral nerve action potentials. The ERS100C is an extremely low noise differential amplifier that accurately amplifies very small potentials, such as those associated with stimulus/response, signal-averaged recordings. Selectable gain and bandwidth options make the module useful for a variety of evoked response testing modes. The ERS100C is intended for use in applications such as auditory brainstem response, startle response, somatosensory evoked response or nerve conduction velocity recording. Specifications Gain 500, 1000, 2000, 5000 Output Range ±10 V (analog) Low Pass Filter 500 Hz, 5000 Hz Specifications High Pass Filter 1.0 Hz, 10 Hz, 100 Hz Gain 5000, 10000, 20000, 50000 Notch Filter 50 dB rejection @ 50/60 Hz Output Range ±10 V (analog) Noise Voltage 0.2 µ V rms (10 – 500 Hz) Low Pass Filter 3 kHz, 10 kHz Z (input) 2 MΩ (Differential) 1000 MΩ (Common mode) High Pass Filter 1.0 Hz, 20 Hz, 100 Hz CMRR 110 dB min (50/60 Hz) Notch Filter 50 dB rejection @ 50/60 Hz CMIV ±10 V (referenced to amplifier ground) ±1500 VDC (referenced to mains ground) Noise Voltage 0.5 µ V rms (100 - 3000 Hz) Z (input) 2 MΩ (Differential) 1000 MΩ (Common mode) CMRR 110 dB min (50/60 Hz) CMIV ±10 V (referenced to amplifier ground) ±1500 VDC (referenced to mains ground) Input Voltage Range: Gain 500 1000 2000 5000 Catalog No. BS4 60-1039 Home Contact Us Previous Next Vin (mV) ±20 ±10 ±5 ±2 $ Product Electromyogram Amplifier Electrooculogram Amplifier The EOG100C amplifies the corneal-retinal potential. The amplifier monitors the DC potential on the skin surrounding the eyes, which is proportional to the degree of eye movement in any direction. The amplifier output can be switched between normal EOG output and Derivative of EOG. In Derivative mode, the amplifier outputs the measured velocity of eye movement, which is useful for saccade and nystagmus investigations. The amplifier permits DC coupling to electrodes for X/Y graphing of eye movement without discernible decay. Specifications Catalog No. Vin (mV) ±2 ±1 ±0.5 ±0.2 $ BS4 60-1063 Model 545.00 ERS100C Product Evoked Response Amplifier Biopotential 100C Interface Cables The Biopotential amplifiers connect to unshielded or shielded electrode leads terminating with Safelead®/Touchproof (1.5mm) sockets. For best performance, use two shielded electrode leads and one unshielded electrode lead per amplifier. See the extensive selection of electrode leads on page I135. For additional electrode lead distance, see the Module Extension Cables on page I139. Gain 500, 1000, 2000, 5000 Output Selection Normal, Derivative output Output Range ± 10 V (analog) Low Pass Filter 35 Hz, 100 Hz High Pass Filter DC, 0.05 Hz Notch Filter 50 dB rejection @ 50/60 Hz All Biopotential Amplifier Specifications Noise Voltage 0.1 µ V rms (0.05 – 35 Hz) Signal Source Electrodes (three electrode leads required) Z (input) 2 MΩ (Differential) 1000 MΩ (Common mode) Dimensions 4 cm (wide) x 11 cm (deep) x 19 cm (high) CMRR 110 dB min (50/60 Hz) Weight 350 g CMIV ±10 V (referenced to amplifier ground) ±1500 VDC (referenced to mains ground) For CBL200, see page I138. Input Voltage Range: Gain 500 1000 2000 5000 Catalog No. BS4 60-1040 I109 Model 545.00 EMG100C Input Voltage Range: Gain 5000 10000 20000 50000 Vin (mV) ±20 ±10 ±5 ±2 $ Model 545.00 EOG100C For CBL204, see page I138. For JUMP100C, see page I139. Product Electrooculogram Amplifier 11,000 Specialty Products to Enhance Your Bioresearch U.S. Toll Free: (800) 272-2775 • Fax: (508) 429-5732 • Online: www.harvardapparatus.com