Hand-held measuring instruments Multi-Handy 3050 and Multi-System 5050 Limburg [sec] p1 0/200 MINMAX ISDS +p2 150 0/200 ° T1 -50/200 <SKAL> Multi System 5050 Intelligent Sensor Detection System !" # $%&' Limburg p1 ( bar) p2 ( bar) p3 ( bar) Q1 (l/min) 120.4 210.6 360.2 160.7 Multi Handy 3050 &' &' &' ! &()& /0(,0 /0-* % ( &'" " #$ *(+ 1234 *,-. Test with confidence Limburg Messen mit System English 1 HYDROcomsys/WIN32 The state-of-the-art link between hand-held measuring instruments and PC Nowadays users expect from a hand-held measuring instrument not only an effortless capturing of data but also the possibility to analyse the data obtained, using sophisticated software running on personal computers. Limburg [sec] p1 0/200 MINMAX +p2 150 0/200 ° T1 -50/200 <SKAL> Multi System 5050 " * 7 8(,9 * 7 8(,9 *" 7 8(,9 7):;9 ! " #$ $ 1234 Limburg %6 %6 "%6 %6 Multi Handy 3050 % $ &' &' &' ! &()& /0(,0 /0-* % &'" " #$ RS232 *(+ 1234 *,-. Years ago HYDROTECHNIK recognised that users require, apart from a powerful measuring device, additional software. HYDROTECHNIK meet the user’s requirements for a simple and fast analysis and documentation of their various measuring with the special data capture software „HYDROcomsys/Win32“. The manufacurer is aware of the fact that the efficiency of a measuring device is increasingly determined by intelligent software. Thus, it is only a logical step that the measuring device is accompanied by state-of-the-art software. Looking at the performance power of this software one may rightly talk of an investimable help for users with the regards to the display, the analysis, the documentation and the presentation of data. 2 Faster results through rational analysis Today’s market is generally dominated by complex software requiring intensive training. The results-oriented engineer requires a user-friendly software that concentrates on the essentials. The program was designed with a functional and simple user interface in mind (Windows-oriented) allowing the user to benefit from it immediately without extensive training. Operation is very simple: select a measuring device, connect the transmission cable, transmit the data online, or from a storage medium to the PC or Laptop, then display and analyse it. The software “HYDROcomsys/WIN32” enables any HYDROTECHNIK measuring device equipped with an RS232 or USB interface to transmit data. Data may be displayed graphically as well as in tables. Graphics may be processed and enhanced with text. Results can be printed or stored as data sheet or report format. Test curves may be transposed to monitor long-term invesitgations; the system also facilitates easy checking of repeat measuring. Results are either stored on diskette or simply transmitted as email attachments. The current line of communication between the service engineer and production or between development dept. and component manufacturer may thus be considerably shortened. This powerful software is a simple link between PC and measuring device and makes advanced analysis possible in numerous industrial systems. See below for the graphical illustration of some characteristics. Presentation as a drawing with measurement curves, comments and logotype Presentation of measuring curves with text, test report, comments and photo (BMP) Presentation of a measuring curve with specific values and logotype (BMP) Presentation with four measurement curves 3 Multi-Handy 3050 with ISDS, compact with great measuring power ISDS (Intelligent Sensor Detection System), - integrated into the HYDROTECHNIK sensors represents the superior sensing method, providing the measuring device with all sensor calibration data automatically. Example: insert the ISDS pressure sensor and start measuring, the measuring device recognises data automatically. Support software HYDROcomsys/WIN 32 comfortable data analysis at the PC Limburg Limburg * 5 6(,7 * 5 6(,7 %9 %9 p1 ( bar) p2 ( bar) p3 ( bar) Q1 (l/min) 120.4 210.6 360.2 160.7 Multi Handy 3050 Multi Handy 3050 Supports many standard printer models Automatic adaptation of the display of values &' &' &' ! &()& /0(,0 /0-* % &'" " #$ *(+ 1234 *,-. The significant advantages • 4 measuring channels • 8 lines of illuminated LCD-display • Text input • Min./Max.-display • Display adaptation • Calculated values • 12 bit A/D-converter • Max.450 000 values / 14 storage places • Centronics-, RS232- and USB-interfaces 4 • Trigger/Pre-trigger (storing) • Menu-driven operation or direct entry • Graphic or tabular printouts • Real-time clock • Battery/ext. power supply 12-30 VDC Description Practical , hand held meausuring devices must be userfriendly. ISDS sensors are automatically detected by the measuring device during the power-up phase and the following parameters are recognised: measuring range, the physical size, the unit of measure, the signal exit and the characteristic curve. Confusing sensors and the need to enter sensor-specific data are, therefore, a thing of the past. The Multi-Handy 3050 with storage capacity and connectivity to many standard printers, real-time clock and PC-interface meets today’s challenges. The unit has a simple to use menu operation similar to that in mobile phones. Up to four sensors may be connected and their measuring results stored simultaneously. Minimum and maximum values are stored continuously and may be displayed at any time. Calculations of values, like difference, sum and performance as well as derivations, e.g., speed are possible. The stored data may be reproduced as a protocol either graphically or as tables via a printer, either immediately or at a later time. The USBinterface of the Mulit-Handy 3050 allows a fast data transfer to a PC. The data analysis software “HYDROcomsys/WIN32” by HYDROTECHNIK manages large data volumes either in graphical or tabular form and or data analysis and there presentation directly on a PC. Technical information about the Multi-Handy 3050 with ISDS reference for the specified data: 20°C ±3K Input channels: Four in total 3 analogue input, 6-pins: 0 to 20 mA, switchable to 4-20 mA 1 frequency input, 6-pins Recognition of connected ISDS sensors Standard measures: Pressure, pressure peaks, pressure differences, volume flow rate, revolutions, direct current, voltage, force, torque, distance and speed are freely selectable with 5-character display revolution: from 60 min -1 (with reference to 1 measuring point) 5-character display Measuring rate: Analogue: 1 ms Frequency input: between 0,25 Hz to 56 Hz a single period measurement. From 56 Hz on the measuring time is constant = 17.7 ms. Resolution A/D converter: 12 bit Extreme value storage: Background storage for all channels, selectable through approriate keys. Measured data storage: Standard 1 MB, approx. 450 000 values in max. measurement series (depending on the selected size). Freely selectable measuring rate between 1 ms to max. 999 minutes. Data storage: Battery powered RAM-storage with time and date. Display: 8 lines, illuminated LCD display (individually selectable), letter size 4 mm. 4 lines will be automatically displayed in double size. Interfaces: Centronics (printer), RS232 (PCs), USB (Universal Serial Bus) for fast data transfer to PCs. Power supply: Internal 14.4 NiCd-battery, 1.1 Ah for approx. 8 hours continous operation with integrated battery charging and charge indicator. External power supply via adapter: 230 VAC / 24 VDC (min. 340 mA) or third party external power supply (stabilised 12 V to 30 VDC). Operation environment: Operating temperature: 0 to+ 50 °C, relative humidity < 80 % (not thawing). Storage temperature range: -40 °C to+ 70 °C General: Casing material: Dimensions: Weight: Technical modifications reserved ABS-plastic approx. 107 x 203 x 76 mm (W x L x H) 0,8 kg 5 Multi-System 5050 with ISDS, the larger version with enhanced facilities ISDS (Intelligent Sensor Detection System), integrated into the HYDROTECHNIK-sensors represents the superior sensing method, providing the measuring device with all sensor calibration data automatically. Support software with Example: ISDS pressure sensor HYDROcomsys/WIN 32All types of ISDS sensors may the comfortable data analysis be connected (max. 6) at the PC Limburg Example: measured values display and graphical display Limburg [sec] p1 = 185.2 p2 = 168.4 p3 = 48.9 Q1 = 85.34 n1 = 1225 T1 = 64.7 dp1 = 16.8 MINMAX bar bar bar l/min U/min °C bar p1 0/200 MINMAX 150 0/200 ° T1 -50/200 Multi System 5050 !" # $%&' Multi System 5050 Supports many standard printers: - Epson - Hewlett Packard - Cannon etc. +p2 <SKAL> Example: external control of a present limit by the measuring device or storeage triggered by an external system ( Example: coupling of two measuring devices to increase the input channels max. of 12 sensors The significant advantages • 6 channels • 16-line LCD display for graphics and text • Text input • Min./Max.-display • Display modification • Calculated values • 12 bit-converter • Max. 500 000 values/ 36 storage places • Centronics-, RS232- and USB-interfaces • Trigger/Pre-trigger and cyclical storage 6 • External trigger input • Switching output • Combination of two trigger conditions • Display of graphical and text analysis • Online-display y= f(t) and y= f (x) • Menu-driven operation or direct entry • Graphical or tabular printout • Date and time display • Battery / ext. power supply 24 to 30 VDC Description State-of-the-art hand held measuring devices must conform with modern technical requirements. Upon power-up it activates a new comfortable sensor recognition covering all ISDS-sensors. The previously required presetting is no longer necessary; measuring may commence immediately. A comfortably readable display presents the stored data graphically. This type of presentation is more meaningful than the laborious calculation of numerous different values. We are convinced that you will not want to miss these functions in the future. Simply follow the logically designed menu to carry out your desired program. By providing a generous storage capacity for 500 000 values, one can accommodate even lengthy measuring processes. The user can select from different internal trigger choices or an external trigger before storing. Technical information about Multi-System 5050 In addition, it is possible to access external devices like an SPS. Calculations of values, like difference, sum and performance as well as derivations, e.g., speed are possible. The stored data may be reproduced as a protocol either graphically or as tables via a printer, either immediately or at a later time, including, of course, date and time. The USB-interface allows a fast data transfer to a PC or laptop. The data analysis software “HYDROcomsys/WIN32” by HYDROTECHNIK manages large data volumes either in graphical or tabular form and or data analysis and their presentation directly at a PC. The integration of data into commom applications like Word® and Excel® is possible. reference for the specified data: 20°C ±3K Input channels: 6 in total 4 analogue inputs, 6-pins: 0 to 20 mA, switchable to 4 to 20 mA or 0 to 10 VDC and two frequency inputs, 6-pins: with direction recognition. One digital input 3.5 to 30 VDC / max. 1 mA, galvanically separated for triggering external signals. One output for external devices, 5 to 30 VDC / max. 10 mA open collector. Recognition of connected ISDS sensors. Standard measures: Pressure, pressure peaks, pressure differences, volume flow rate, revolutions, direct current, voltage, force, torque, distance and speed are freely selectable with 5-character display and floating point. Measuring rate: Analogue: Frequency input: Resolution A/D converter: 12 bit Extreme value storage: Background storage for all channels, selectable through appropriate keys. Measured data storage: Standard 1 MB, approx. 500 000 values in max. 36 measuring series (depending on the selected sizes). Analogue status display (bar chart), freely selectable measuring rate between 1 ms to max. 999 minutes. Data storage: Battery powered RAM-storage with time and date. Display: 16 lines, illuminated LCD display (individually selectable), letter size 4 mm. Up to 7 lines will be automatically displayed in double size. Interfaces: Centronics (printer), RS232 (PCs), USB (Universal Serial Bus) for fast data transfer to PCs. Power supply: Internal 14.4 V NiCd-battery, 1.1 Ah for approx. 6 hours continuous operation with integrated battery charging and charge indicator. External power supply via adapter: 230 VAC / 24 VDC (min. 340 mA) or third party external power supply (stabilised 18 V to 30 VDC). Operating environment: Operating temperature: 0 to+ 50 °C, relative humidity < 80 % (not thawing). Storage temperature range: -40 °C to+ 70 °C General: Casing mterial: Dimensions: Weight: Technical modifications reserved 1 ms between 0,25 Hz to 91 Hz a single period measurement. From 91 Hz on the measuring time is constant = 10.9 ms ABS-plastic approx. 108 x 277 x 84 mm (W x L x H) 1,4 kg 7 At a glance (Comparing both hand held measuring devices) Limburg Limburg Multi-Handy 3050 3160 - 00 - 63 .00 p1 ( bar) p2 ( bar) p3 ( bar) Q1 (l/min) 120.4 210.6 360.2 160.7 Multi Handy 3050 &' &' &' ! &()& /0(,0 /0-* % &'" " #$ Multi-System 5050 3160 - 00 - 62 .00 *(+ 1234 *,-. [sec] p1 0/200 MINMAX +p2 150 0/200 ° T1 Multi System 5050 8 Total of 4 3 analogue inputs, 0 to 20 mA and 4 to 20 mA 1 frequency input ISDS transducer recognition !" # $%&' ( No. of channels or inputs -50/200 <SKAL> Total of 6 4 analogue inputs 0 to 20 mA, 4 to 20 mA and 0 to 10 VDC 2 frequency inputs ISDS transducer recognition Extra digital input 1, galvanically separated, 3,5 to 30 VDC / max. 1 mA to trigger external signals Control output For connection to external devices, 5 to 30 VDC / max. 10 mA open collector Internally calculated values 1 x difference, sum, hydraulic power, derivation: speed from displacement 3 x difference, sum, hydraulic power, derivation: speed from displacement Display Only text with optional background illumination. Letter size 4 mm, automatic adjustment to maximum display size: 128 x 64 pixel / 70 x 39 mm (W x H) Display automatically adjusts to double size for four or less values. Text and graphics Letter size 4 mm, automatic adjustment to maximum display size: 160 x 128 pixel / 92 x 74 mm (W x H) Display automatically adjusts to double size for four or less values Resolution A/D-converter 12 Bit 12 Bit Storage channels 5 8 Memory storage/ measuring values 14 storage locations/ 450 000 readings for frequencies 150 000 readings 36 storage locations / 500 000 readings for frequencies 170 000 AD readings Measuring rate Freely selectable from 1 ms to 999 minutes Freely selectable from 1 ms to 999 minutes Linear tables Only in connection with ISDS sensors 5 per channel Interfaces Centronics, RS 232 and USB Centronics, RS 232 and USB ISDS-recognition Yes Yes Storage functions Manual storage Triggered storage (1 trigger condition) Manual storage Triggered storage Cyclical storage Combination of max. 2 trigger conditions External trigger No Yes Printout (Printer) Graphics and tables Graphics and tables Graphical curve display No Yes Real-time clock Yes Yes Power supply 12 to 30 VDC 18 to 30 VDC Ordering information Hand-held measuring devices Order-number Hand-held measuring instrument: Multi-Handy 3050 3160 - 00 - 63. 00 Hand-held measuring instrument: Multi-System 5050 3160 - 00 - 62. 00 Replacement battery (only for Multi-System 5050) 8873 - 02 - 00. 07 Desktop power supply: 230 VAC/24 VDC/340 mA 8812 - 00 - 00. 28 Socket power supply: 230 VAC/24 VDC/340 mA 8812 - 00 - 00. 19 Socket power supply: 115 VAC/24 VDC/350 mA 8812 - 00 - 00. 20 Carrying case: (only for Multi-System 5050) 8875 - 01 - 04. 00 Carrying case: (only for Multi-Handy 3050) 8875 - 01 - 05. 00 Sensors with ISDS (Intelligent Sensor Detection System) Order number ISDS allows for the automatic recognition of sensors by hand-held measuring instruments: Multi-Handy 3050 and Multi-System 5050. The previously required entry of sensor parameters is a thing of the past. The measuring device detects through the sensor the measuring range, the physical size, the measuring unit, the output signal and the characteristic curve. – Pressure Pressure sensor type HT-PD (ISDS) (Output signal: 0 to 20 mA) Range Range Range Range Range -1 0 0 0 0 to + 6 bar to 60 bar to 200 bar to 400 bar to 600 bar 3403 3403 3403 3403 3403 - 32 - S - E5.33 21 - S - E5.33 10 - S - E5.33 15 - S - E5.33 18 - S - E5.33 31V7 31V7 31V7 31V7 - 01 - S 70 - S 71 - S 72 - S - Further ranges on request – Volume flow rate: Measuring turbine RE 4 (ISDS) (Inductive sensor with amplifier) Output signal (rectangular) Range 1,0 to 10 I/min Range 2,0 to 75 I/min Range 9,0 to 300 I/min Range 16,0 to 600 I/min All measuring turbines with MINIMESS and p/T-coupling (series 1620) (For further technical information see our separate brochure volume throughput sensors) – Testing device loading valve (ISDS) Allows for example load checks for pumps (hydraulic load simulations) Loading valve Range 12 to 600 l/min (with fixing clamps) – Volume flow rate: Gear-wheel sensor type GFM (ISDS) Output signal (square wave) Range 0,005 to 1 I/min Range 0,05 to 5 I/min Range 0,2 to 30 I/min Range 0,7 to 70 I/min Range 3,0 to 300 I/min All sensors with MINIMESS and p/T-coupling (series 1620) (For further technial information see our separate brochure volume throughput sensors) – Temperature Range -50 to +200 °C Temperature probe Pt 100 (ISDS) (screw-in) Output signal 0 to 20 mA for p/T-measuring coupling series 1620 (code 04) 35.00 35.00 35.00 35.00 31VB - 72 - 35 . 00S2 3143 3143 3143 3143 3143 - 01 - S 02 - S 03 - S 04 - S 05 - S - 35.00 35.00 35.00 35.00 35.00 3973 - 04 - S - 01.00 – Measuring cable MKS (length 2,5 m) 8824 - S1 - 02 . 50 – Measuring cable AKS to connect sensors to the following devices without ISDS: Series 8000, 5000, 4010, 4020, 3000, 2040, 2045 and 2050. (ISDS-recognition is not possible with these devices) 8824 - S2 - 02 . 50 9 Sensors (standard without ISDS, ) Order-number -1 to 0 to 0 to 0 to 0 to 0 to + 6 bar 60 bar 200 bar 400 bar 600 bar 1000 bar 3403 - 32 - C3.37 3403 - 21 - C3.37 3403 - 10 - C3.37 3403 - 15 - C3.37 3403 - 18 - C3.37 3403 - 29 - C3.37 – Pressure Pressure sensor type HT-PD (Output signal: 4 to 20 mA) Range Range Range Range Range Range – Temperature probe (screw-in) Pt 100 (two wire technology) Range -50 bis +200 °C 3969 - 04 - 01.00 Range -50 to +200 °C 3170 - 01 - 03.00 Range -50 to +200 °C 3170 - 02 - 06.00 Range Range 0 to 60 bar / Range -50 bis +200 °C 0 to 600 bar / Range -50 bis +200 °C 3163 - 04 - 34.00 3163 - 03 - 34.00 Range Range Range 7,5 to 75 I/min 15,0 to 300 I/min 25,0 to 600 I/min 31V7 - 21 - 35.00 31V7 - 30 - 35.00 31V7 - 40 - 35.00 output signal 4 to 20 mA for p/T couplings series 1620 (code 4) – Surface temperature gauge Pt 100 (two wire technology) output signal 4 to 20 mA incl. spiral cable 1,2 m – Temperature immersion sensor Pt 100 two wire technology) output signal 4 to 20 mA incl. spiral cable 1,2 m – Pressure / Temperature p/T-dual sensor (separate output signal: 2 x 4 to 20mA) for simultaneous measuring of temperature and pressure Both for p/T measuirng couplings, series 1620 (code 04) – Volume flow rate: Measuring turbine RE 3 (Inductive with amplifier) Output signal (square wave) – Measuring turbine RE 4 (Inductive with amplifier) Output signal (square wave) Range 1,0 to 10 I/min 7,5 to 75 I/min Range 15,0 to 300 I/min Range Range 25,0 to 600 I/min All measuring turbines with MINIMESS and p/T-coupling (series 1620) (For further technical information see our separate brochure volume flow rate sensors) – Volume flow rate: Gear-wheel sensor type GFM Output signal (square wave) Range 0,005 to 1 I/min Range 0,05 to 5 I/min Range 0,2 to 30 I/min Range 0,7 to 70 I/min Range 3,0 to 300 I/min All sensors with MINIMESS and p/T-couplings (series 1620) (For further technical information see our separate brochure volume flow rate sensors) – RPM infrared sensor type DS 03: incl. 25 reflection foils – Inductive sensor with amplifier (measuring RPM at gear wheels) – Reflection foil (replacement 50 pieces) – Magnetic holder for RPM sensor DS 03 10 31V7 - 01 - 35.00 31V7 - 70 - 35.00 31V7 - 71 - 35.00 31V7 - 72 - 35.00 3143 - 01 - 35.00 3143 - 02 - 35.00 3143 - 03 - 35.00 3143 - 04 - 35.00 3143 - 05 - 35.00 Range 1 to 9999 min -1 3130 - 02 - 01.00 Range 1 to 9999 min -1 3107 - 00 - 09.00 8840 - 02 - 01.01 3130 - 03 - 01.00 Accessories Order -number – Split cable for dual sensor (length 2,5 m) to connect to p/T dual sensors – Car adapter (length 5,0 m) for external power supply – Trigger cable for external control or storage activation (length 5,0 m) – Connecting cable (parallel connection of two measuring devices, only Multi-System 5050) 8824 - D6 - 02.50 – Carrying case (plastic box) – Carrying case I – Carrying case II (with add. compartment for measuring turbines) 3160 - 00 - 62.04 3160 - 00 - 62.02 3160 - 00 - 62.03 – Battery powered ink jet colour printer with mains adapter and ink cartridges (100 to 240 VAC-50/60Hz) – Replacement ink cartridge black – Replacement ink cartridge colour – Data transfer cable Centronics 36-pins/25-pins 8865 - 01 - 14.00 – Direct connection for pressure sensor type HT-PD – straight (series 1620 - M 16x2) – Direct connection for pressure sensor type HT-PD – 90° angle (series 1620 - M 16x2) – p/T-measuring coupling 1620 (code 04) screw-in type M 10x1 – p/T-measuring coupling 1620 (code 04) screw-in type ISO 228-G1/4 2103 2146 2149 2149 – Voltage measuring (external adapter) with output signal 0 to 20 mA Range 0 to ±48 VDC – Current measuring (external adapter) with output signal 0 to 20 mA Range 0 to ±2 ADC 3160 - 00 - 00.22 – Data transfer cable RS 232 9-pins/ 25-pins – Data transfer cable USB (length 1,5 m) 8824 - 44 - 02.00 8824 - F4 - 01.50 8824 - 64 - 05.00 8824 - D8 - 05.00 8824 - F2 - 00.50 8865 - 01 - 09.02 8865 - 01 - 10.02 8824 - 36 - 02.00 - 07 - 18.62 13 - 05.00 04 - 19.13 04 - 15.13 3160 - 00 - 00.23 – Support software “HYDROcomsys/WIN32” for the display and the analysis of measurements at the PC. (Supplied with all hand held measuring devices with RS232 interface). Test and logging instruments Input PC/Printer 8000 Memorycard Multi Control Interface Power Limburg p1 = p2 = 128.6 117.8 bar bar Multi Handy 2040 ON Limburg Min. 0-20 ! "!# $ # %% %& ' (!# %) *$ !# + ! ) ' Max. Chn.1 Chn.2 Rel.1 4-20 Rel.2 OFF SI Prog./Displ. US p1 n Prog. Chn.1 Max. Peak Chn.2 Limburg Channel compare analog Rel.1 p (p1-p2) Q Min. p2 p 128.6 p1 = [bar] T Rel.2 Prog./Displ. Prog. Peak Channel Multi Handy 2045 Prog ENT 0-20 4-20 SET 1 OFF n p1 T Q Scale max. min. ALARM p (p1-p2) Limburg CAL 2 Analog p2 p Test with confidence compare digital Limburg ON SET 1 2 3 4 SEG 1050 Memory Scan Printer Prog Start Stop ENT Limburg Messen mit System Test with confidence 8000 instrument – 12 channel powerful data logging with touch screen control. The 8000 series instruments has been developed to meet the needs of more sophisticated levels of monitoring in Hydraulic and Engine testing environments. Limburg Messen mit System Test with confidence Hand held measuring instruments of series 2040 and 2045 for daily checks and control. Perfect for the Service and Plant Engineer. Limburg Messen mit Syste Panel mounted instrument for monitoring, measuring and controlling purposes. 11 Test with confidence Limburg 12 Messen mit System HYDROTECHNIK GmbH • Holzheimer Straße 94-96 • D-65549 Limburg • Tel. ++49 (0)6431/4004-0 • Fax 45308 Internet: http://www.hydrotechnik.com • e-Mail: info@hydrotechnik.com 07/02 - 8898-01-00.42