Specs

advertisement
Reversing DC Motor
Speed Control
130 Series
l Provides DC Motor Speed Control with
OMDC-130LC100
shown smaller
than actual size.
Reversing Capability
l Speed Regulation is ±1% of Base Speed
l Adjustable Minimum/Maximum Speed
l Adjustable Current Limit
l Speed Adjustment Using 5 kΩ Speedpot or
0 to 10 Vdc Analog Input Signal
l Onboard Dynamic Braking Resistor
l 5K Speed Pot with 8" Leads, Dial and Knob Included
l 50:1 Speed Range
Applications
l Door Openers
l Feeders
l Tapping Machines
l Pumps
l Screen Presses
l Conveyors
The 130 Series reversing speed control is designed to provide instant
reversing, quick precise stopping or rapid cycling for a wide range of
DC motor applications. The 130 Series reversing control outperforms
other dynamic braking and reversing controls by utilizing unique zerospeed detect and dynamic braking circuits. These circuits eliminate
the contact arcing and failed braking problems associated with other
reversing and dynamic braking controls. The zero speed detect circuit
also eliminates motor plug reversing problems. In the event of a
power loss or emergency stop condition, the 130 Series control will
drop into a dynamic brake condition to safely and quickly bring the
motor to a stop and remain there until power is reapplied and a run
condition is recognized.
SPECIFICATIONS
AC Input Voltage: ±10% of rated line voltage
Acceleration: 0.5 seconds
Amps–DC Output
130xx12 and 132xx25: 500 mA to 1.2 ADC
130LC100 and 132LC200: 500 mA to 5.5 ADC*
130HC100 and 132HC200: 500 mA to 10 ADC
Controller Overload Capacity: 200% for one minute
Current Limit Trimpot Range
Models 130xx100 and 132xx200: 1 to 18 ADC
Deceleration: 0.5 seconds
Dimensions:
LC Models: 126.16 W x 107.95 L x 68.27 mm D
(4.96 x 4.25 x 2.68")
HC Models: 158.75 W x 177.8 L x 103.2 mm D
(6.25 x 7.0 x 4.06")
Weight:
LC Models: 489.87 g (1.08 lb)
HC Models: 1496.80 g (3.30 lb)
Drive Service Factor: 1.0
Efficiency: 85% typical
Input Frequency: 50 or 60 Hz
Trimpot Speed Range
Maximum: 60 to 110% of base speed
Minimum: 0 to 30% of maximum speed
Power Devices: Isolated case tab
Shunt Field Voltage: 100 Vdc for 120 Vac input; 200 Vdc for
240 Vac input
Shunt Field Current: 1 amp DC maximum
Speed Control: Via 5 kΩ 0.5 W potentiometer or 0 to 10 Vdc
isolated signal
Speed Range: 50:1
Speed Regulation: ±1% of base speed
Temperature Range: -10 to 45°C ambient (15 to 115°F)
Terminal Block Torque Setting: 4.4 in. lb. maximum
or 0.05 Nm
Transient Protection: G-Mov
Trigger: Opto-isolator
Start/Brake Cycle Per Minute
LC Models: 3 per min**
HC Models: 30 per min**
Operating Conditions
Temperature: -10 to 45°C (14 to 113°F)
AC Input Voltage: ±10% rated line voltage
Input Frequency: 50/60 Hz
* With suitable external heat sink (where 130 extrusion temperature
does not exceed 70°C), maximum rating for output amps can be
increased to 10 amps D.C.
** Cycles per minute are based on typical inertia type loads. Higher
cycle per minute rates may be achieved with constant torque or low
inertia type loads. Lower cycle rates may be required for very high
inertia type loads.
1
128.5 (5.06)
126 (4.967)
92
LC Models
128.5 (5.06)
(3.628)
128.517(5.06)
126 (4.967)
(0.677)
44.5
92
126 (4.967)
(1.75)
92
(3.628)
128.5
(5.06)
17
(3.628)
126
(4.967)
17
(0.677)
44.5
92
(0.677)
44.5
(1.75)
(3.628)
(1.75)
17
(0.677)
44.5
(1.75)
17.5 (0.688)
HC Models
17.5 (0.688)
17.5 (0.688)
17.5 (0.688)
Dimensions: mm (inch)
143
(5.625)
178
(7.0)
143
143
(5.625)
(5.625)
108
(4.25)
178
178
(7.0)
(7.0)
143
(5.625)
108
108
(4.25)
(4.25)
178
(7.0)
108
(4.25)
5.5
(0.218)
143 (5.625)
6.25 (159)
143 (5.625)
143 (5.625)
6.25 (159)
6.25 (159)
143 (5.625)
6.25 (159)
5.5
5.5
(0.218)
(0.218)
4.77 (0.188)
11/32
DIAMETER
SLOT DEPTH
(6 SLOTS) 11/32 (6 SLOTS)
4.77 (0.188)
11/32
4.77
(0.188)
SLOT
DEPTH
DIAMETER
DIAMETER
SLOT
DEPTH
(6 SLOTS)
(6 SLOTS)
(6 SLOTS)
(6 SLOTS)
4.77 (0.188)
11/32
DIAMETER
SLOT DEPTH
(6 SLOTS)
(6 SLOTS)
5.5
(0.218)
103
(4.063)
103
103
(4.063)
(4.063)
67
67
(2.645)
(2.645)
35
103
(1.375)
(4.063)
35
35
(1.375)
(1.375)
35
(1.375)
66
(0.249)
(0.249)
67
(2.645)
67
(2.645)
6
(0.249)
95
95
(3.75)
(3.75)
95
(3.75)
95
(3.75)
6
(0.249)
33
(1.295)
33
10
33 (0.385)
(1.295)
(1.295)
10
10
(0.385)
33
(0.385)
(1.295)
10
(0.385)
Hook-Up Diagram
TYPICAL MOTOR CURRENTS
Horsepower
1/50
1/20
1/8
1/4
1/3
1/2
3/4
1.0
1.5
2.0
Typical AC Amps (120 Vac)
0.50
1.00
2.00
3.50
4.40
6.50
9.30
13.20
—
—
Typical Arm Amps (120 Vac)
0.42
0.871
1.60
2.70
3.40
5.00
8.20
10.90
—
—
Typical AC Amps (240 Vac)
—
0.80
1.20
1.80
2.20
3.30
4.80
6.50
9.70
12.90
Typical Arm Amps (240 Vac)
—
0.40
0.60
1.40
1.70
2.50
3.70
5.00
8.20
11.60
To Order Visit omega.com/130_series for Details and Pricing
Model NO.
Description
OMDC-130LC100
Reversing DC Drive, 120 Vac input, 0 to 90 Vdc output, ½ HP, 5.5A current*, 3 cycles/minute
OMDC-130HC100
Reversing DC Drive, 120 Vac input, 0 to 90 Vdc output, 1 HP, 10A current, 30 cycles/minute
OMDC-132LC200
Reversing DC Drive, 240 Vac input, 0 to 180 Vdc output, 1 HP, 5.5A current**, 3 cycles/minute
OMDC-132HC200
Reversing DC Drive, 240 Vac input, 0 to 180 Vdc output, 2 HP, 10A current, 30 cycles/minute
OMDC-HS125
Heat Sink for higher current output (LC100/LC200 models)
Comes complete with manual, speedpot kit, dial and knob.
* Up to 10A continuous current output at 1 HP 90 Vdc with heat sink.
** Up to 10A continuous current output at 2 HP 180 Vdc with heat sink.
Ordering Example: OMDC-130LC100, reversing DC drive speed control.
2
Download