Ramah Navajo Chapter Detention Facility Lordsburg, New Mexico SECTION 08-3113 ACCESS DOORS AND FRAMES PART1 -GENERAL 1.1 RELATED DOCUMENTS A. 1.2 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY A. This Section includes the following: 1. B. 1.3 Access doors and frames for walls and ceilings at non-secure locations. Related Sections include the following: 1. Division 04 Section "Reinforced Unit Masonry" for anchoring and grouting access door frames set in masonry construction. 2. Division 22 Section "Plumbing 3. Division 23 Section "Heating, ventilation and air conditioning". 4. Division 26 Section "Electrical" SUBMITTALS A. Product Data: For each type of access door and frame indicated. Include construction details, fire ratings, materials, individual components and profiles, and finishes. B. Shop Drawings: Show fabrication and installation details of access doors and frames for each type of substrate. Include plans, elevations, sections, details, and attachments to other work. 1.4 QUALITY ASSURANCE A. Source Limitations: Obtain each type of access doors and frames through one source from a single manufacturer. B. Fire-Rated Access Doors and Frames: Units complying with NFPA80 that are identical to access door and frame assemblies tested for fire-test-response characteristics per the following test method and that are listed and labeled by UL or another testing and inspecting agency acceptable to authorities having jurisdiction: 1. 2. C. A10.14 NFPA252or UL 10B for vertical access doors and frames. ASTM E 119 or UL 263 for horizontal access doors and frames. Size Variations: Obtain Architect's acceptance of manufacturer's standard-size units, which may vary slightly from sizes indicated. 08-3113-1 Raman Navajo Chapter Detention Facility Lordsburg, New Mexico 1.5 COORDINATION A. Verification: Determine specific locations and sizes for access doors needed to gain access to concealed plumbing, mechanical, or other concealed work, and indicate in the schedule specified in "Submittals" Article. PART 2 - PRODUCTS 2.1 STEEL MATERIALS A. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M. 1. 2. B. ASTM A 123/A 123M, for galvanizing steel and iron products. ASTM A 153/A 153M, for galvanizing steel and iron hardware. Rolled-Steel Floor Plate: ASTM A786/A786M, rolled ASTM A 36/A 36M or ASTM A 283/A 283M, Grade C or D. 1. 2. from plate complying with ASTM A 123/A 123M, for galvanizing steel and iron products ASTM A 153/A 153M, for galvanizing steel and iron hardware. C. Steel Sheet: Uncoated or electrolytic zinc-coated, ASTM A 591/A 591M with cold-rolled steel sheet substrate complying with ASTM A 1008/A 1008M, Commercial Steel (CS), exposed. D. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS) with A60 zinc-ironalloy (galvannealed) coating or G60 mill-phosphatized zinc coating; stretcher-leveled standard of flatness; with minimum thickness indicated representing specified thickness according to ASTMA924/A924M. E. Steel Finishes: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. 1. 2. Surface Preparation for Steel Sheet: Clean surfaces to comply with SSPC-SP1, "Solvent Cleaning," to remove dirt, oil, grease, or other contaminants that could impair paint bond. Remove mill scale and rust, if present, from uncoated steel, complying with SSPC-SP 5/NACE No. 1, "White Metal Blast Cleaning," or SSPC-SP 8, "Pickling." Surface Preparation for Metallic-Coated Steel Sheet: Clean surfaces with nonpetroleum solvent so surfaces are free of oil and other contaminants. After cleaning, apply a conversion coating suited to the organic coating to be applied over it. Clean welds, mechanical connections, and abraded areas, and apply galvanizing repair paint specified below to comply with ASTM A 780. a. 3. 4. 5. A10.14 Galvanizing Repair Paint: High-zinc-dust-content paint for re-galvanizing welds in steel, complying with SSPC-Paint 20. Factory-Primed Finish: Apply shop primer immediately after cleaning and pre-treating. Baked-Enamel Finish: Immediately after cleaning and pre-treating, apply manufacturer's standard two-coat, baked-enamel finish consisting of prime coat and thermosetting topcoat. Comply with paint manufacturer's written instructions for applying and baking to achieve a minimum dry film thickness of 2 mils. Powder-Coat Finish: Immediately after cleaning and pre-treating, apply manufacturer's standard thermosetting polyester or acrylic urethane powder coating with cured-film 08-3113-2 Ramah Navajo Chapter Detention Facility Lordsburg, New Mexico thickness not less than 1.5 mils. Prepare, treat, and coat metal to comply with resin manufacturer's written instructions. F. Drywall Beads: Edge trim formed from 0.0299-inch zinc-coated steel sheet formed to receive joint compound and in size to suit thickness of gypsum board. G. Plaster Beads: Casing bead formed from 0.0299-inch zinc-coated steel sheet with flange formed out of expanded metal lath and in size to suit thickness of plaster. 2.2 STAINLESS-STEEL MATERIALS A. Rolled-Stainless-Steel Floor Plate: ASTM A 793, manufacturer's standard finish. B. Stainless-Steel Sheet, Strip, Plate, and Flat Bars: ASTM A 666, Type 304. Remove tool and die marks and stretch lines or blend into finish. 1. 2.3 Finish: Manufacturer's standard. ACCESS DOORS AND FRAMES FOR WALLS AND CEILINGS A. Manufacturers: following: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. B. 3. 4. 5. Locations: Wall and ceiling surfaces. Door: Minimum 0.060-inch- thick sheet metal in the form of a pan recessed 5/8 inch 1 inch for gypsum board and acoustical tile infill. Frame: Minimum 0.060-inch- thick sheet metal with drywall bead for gypsum board surfaces and for insertion into acoustical tile ceiling. Hinges: Spring-loaded, concealed-pin type. Lock: Self-latching device with cylinder lock. Exterior Flush Access Doors and Frames with Exposed Trim: Weatherproof with extruded door gasket. 1. A10.14 Acudor Products, Inc. Babcock-Davis; A Cierra Products Co. Bar-Co, Inc. Div.; Alfab, Inc. Cendrex Inc. Dur-Red Products. Elmdor/Stoneman; Div. of Acorn Engineering Co. Jensen Industries. J. L. Industries, Inc. Karp Associates, Inc. Larsen's Manufacturing Company. MIFAB, Inc. Milcor Inc. Nystrom, Inc. Williams Bros. Corporation of America (The). Recessed Access Doors and Trimless Frames: Fabricated from metallic-coated steel sheet. 1. 2. C. Subject to compliance with requirements, provide products by one of the Locations: Wall and ceiling surfaces. 08-3113-3 Ramah Navajo Chapter Detention Facility Lordsburg, New Mexico 2. 3. 4. 5. D. Door: Minimum 0.040-inch- thick, metallic-coated steel sheet; flush panel construction with manufacturer's standard 2-inch- thick fiberglass insulation. Frame: Minimum 0.060-inch- thick extruded aluminum. Hinges: Continuous piano, zinc plated. Lock: Dual-action handles with key lock. Fire-Rated, Insulated, Flush Access Doors and Trimless Frames: Fabricated from metalliccoated steel sheet. 1. 2. 3. 4. 5. 6. 7. 8. 9. Locations: Wall and ceiling surfaces. Fire-Resistance Rating: Not less than that of adjacent. Temperature Rise Rating: 250 deg F at the end of 30 minutes. Door: Flush panel with a core of mineral-fiber insulation enclosed in sheet metal with a minimum thickness of 0.036 inch. Frame: Minimum 0.060-inch- thick sheet metal with drywall bead. Hinges: Concealed-pin type. Automatic Closer: Spring type. Latch: Self-latching device operated by flush key with interior release. Lock: Self-latching device with cylinder lock. a. 2.4 Lock Preparation: Prepare door panel to accept cylinder specified in Division 08 Section "Door Hardware." FABRICATION A. General: Provide access door and frame assemblies manufactured as integral units ready for installation. B. Metal Surfaces: For metal surfaces exposed to view in the completed Work, provide materials with smooth, flat surfaces without blemishes. Do not use materials with exposed pitting, seam marks, roller marks, rolled trade names, or roughness. C. Latching Mechanisms: Furnish number required to hold doors in flush, smooth plane when closed. 1. 2. For cylinder lock, furnish two keys per lock and key all locks alike. For recessed panel doors, provide access sleeves for each locking device. plastic grommets and install in holes cut through finish. Furnish PART 3 - EXECUTION 3.1 INSTALLATION A. Comply with manufacturer's written instructions for installing access doors and frames. B. Install doors where indicated on drawings and where required for access to utility disconnect valves and switches. C. Set frames accurately in position and attach securely to supports with plane of face panels aligned with adjacent finish surfaces. D. Install doors flush with adjacent finish surfaces or recessed to receive finish material. A10.14 08-3113-4 Ramah Navajo Chapter Detention Facility Lordsburg, New Mexico 3.2 ADJUSTING AND CLEANING A. Adjust doors and hardware after installation for proper operation. B. Remove and replace doors and frames that are warped, bowed, or otherwise damaged. END OF SECTION 08-3113 A10.14 08-3113-5