Compliance Table for C2I2 Systems Compliance Table for C²I² Systems' PMC FDDI DAS Network Interface Card (NIC) Compliance Table in PDF-format. Requirement Compliance Specification ANSI X3T9.5 Yes Complies to ANSI X3T9.5 and X3T12. Locations for 64 CAM Addresses No The AMD Supernet III chipset provides for 32 Multicast Address Entries in the Address Filter (AF). Each entry consists of a 48-bit comparand, a 48-bit mask and a 6-bit ‘personality’. SMT V7.3 Yes Comply. Dual ST Connectors Yes Dual FDDI ST receptacles provided on the DAS version. AMD FDDI Chipset Yes AMD Supernet III chipset used. Support for Dual-Homing Configuration Yes Dual-Homing and Alternate Path Configurations supported. Synchronous and Asynchronous Bandwidth Yes SBA and ESS supported in addition to Asynchronous bandwidth. LynxOS V3.0 driver support We do not have a LynxOS drivers available at present. C²I² Systems could supply LynxOS drivers 4 months after order as we already have similar drivers for VxWorks. AIX V4.2/3 driver support Yes Supplied on request. Windows NT V4.0 support Yes Supplied on request. Temperature Operating: Yes Tested from -15 C to +71 C in a thermal chamber, with no forced air over the card, only normally circulating air in the chamber. 0 C to +55 C (ambient) Refer to Item No 30. Relative Humidity Operating : 0 % to 95 % Non-Condensating Yes Altitude Operating : -300 m to +3 000 m Yes Operating altitude capable of +9 000 m (30 000 ft). Temperature Non-Operating : -40 C to +85 C Yes Refer to Item No 11: Operating Temperature. Relative Humidity Non-Operating : 0 % to 95 % Non-Condensating Yes Altitude Non-Operating : -300 m to +19 000 m Yes Shock : 20 g for 11 ms Yes Tested to: 30 g for 11 ms (half sine shock pulses). Vibration : 5 to 500 Hz at 2 g Yes Tested to: - Sine: 10 g (peak) 15 to 2 kHz - Sweep duration 10 minutes per axis - Random: 0,04 g 2/Hz at 15 to 2 kHz Page 1 Compliance Table for C2I2 Systems - 60 minutes per axis Inclination : 0° ±180° Yes PMC FDDI DAS not affected. Noise : Standard Commercial Yes Operational warm-up time : 0 seconds Yes PMC FDDI DAS operational immediately after power supplied. Air Flow Requirement : 96 m (linear) per minute Yes Refer to Item No. 11: Operating Temperature. Our PMC FDDI DAS board can operate within the temperatures required without forced-air. Link Confidence (LC) test parameter in drivers to be supplied with LC_Short = 5 ms (** Refer to note at end of Appendix) Yes LynxOS Driver will be changed per user requirement. AIX Driver will be modified if required by the user, but will be dependent on an NRE charge as driver source code needs to be purchased and modified. Windows NT Driver will be modified if required by the user, but will be dependent on an NRE charge as driver source code needs to be purchased and modified. Additional Supporting Information PCI Compatibility 32-bit PCI-Bus electrical, complies to PCI Rev. 2.1 PMC Compatibility PMC form-factor, complies to CMC IEEE P1386.1 Optical Bypass Optical Bypass Switch (OBS) Control provided. OBS Connector Hirose 6-pin connector. MTBF Figures according to MIL-HDBK-217F, Parts Count Method : Ground Mobile T j = 65 C, T a = 45 C 19 000 hours Naval, Sheltered T j = 60 C, T a = 40 C 26 000 hours Airborne, Inhabited Cargo T j = 75 C, T a = 55 C 20 000 hours Power Requirements < 1,45 A @ 5 V Typical Driver Throughput Performance > 8 Mbyte/s (>56 Mbit/s) (VxWorks on DY4 SVME-179) One of our customers has measured in excess of 9 Mbyte/s (72 Mbit/s). Extended Operating Temperatures with Tested from -40 C to +81C in a thermal chamber, with no forced-air over Industrial Grade Components the card, only normally circulating air in the chamber. Page 2