TECHNICAL MANU
AL
MANUAL
PBC/PBE/PBH
Through-The-Wall R-410A
Air Conditioners & Heat Pumps
• All safety information must be followed
See Installation instructions for more safety precautions.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
Copyright © 2010 Goodman Company, L.P.
RT4271001
May 2010
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
PBC
09 3 E
35 A X
BASIC MODEL TYPE
PBC = Standard Cooler TTW
PBE = Electric Heat TTW
PBH = Heat Pump TTW
AA
MAJOR/MINOR DESIGN REV.
COOLING CAPACITY
09 = 9000 BTUH
12 = 12000 BTUH
RATED VOLTAGE
2 = 115V 60Hz 1Ph
3 = 230/208V 60Hz 1Ph
DESIGN SERIES (Refrig)
A = R-22
E = R-410A
HEATER SIZE
00 = no electric heat
FEATURE CODE
MA = Standard Model R-22
AX = Standard Model R-410A
35 = 3.5 kw (230/208V)
Use up to 4 as needed
In alphabetical order
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Goodman will not be responsible
for any injury or property damage
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
WARNING
2
ONLY individuals meeting (at a
minimum) the requirements of
an "Entry Level Technician" as specified by the AirConditioning, Heating, and Refrigeration Institute (AHRI)
may use this information. Attempting to install or repair
this unit without such background may result in product
damage, personal injury, or death.
WARNING
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
PBC092E00AX
PBC122E00AX
PBC093E00AX
PBC123E00AX
PBE093E35AX
PBE123E35AX
PBH092E12AX
PBH093E35AX
PBH113E35AX
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR
INSTALLING THIS UNIT. MULTIPLE POWER
SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.
WARNING
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by
Goodman for use with this unit.
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
WARNING
To prevent the risk of property
damage, personal injury, or death,
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.
WARNING
3
PRODUCT DESIGN
PBC, PBE and PBH through-the-wall room air conditioners
are designed for window installations in residential applications and are available in 9,000 through 18,000 BTUH sizes.
They are designed for 208/230/115 volt single phase applications.
The provided filter must be installed and under no circumstances should the unit be operated without the filter in place.
NOTES:
1. Mechanical experience is required to install the air
conditioner or heat pump.
2. Installation can take from 1 to 3 hours, depending on
installer’s knowledge and skill.
3. If you encounter problems during installation, call our
consumer information line toll-free at 1-877-376-0214 (U.S.
and Canada only). If your problem cannot be resolved by
phone, contact an authorized Amana brand servicer.
Contact and service will be at your expense.
®
Location and Clearances
Be sure electrical service is adequate for chosen model of
air conditioner or heat pump. Complete electrical rating for
unit is found on serial plate located behind front grille. Electrical outlet must be close enough to unit for power cord to
reach without strain.
Air conditioner should be the only appliance on individual
circuit.
For personal safety and to avoid possible damage to appliance or home, observe all safety instructions.
4
SPECIFICATIONS
MODEL
PBC***E00AX
PBC092E00AX
PBC122E00AX
PBC093E00AX
PBC123E00AX
9200
11800
9200
8900
11800
11400
@ EER
9.8
9.4
9.8
9.8
Cooling Watts
940
1260
940 - 910
1200 - 1160
Cooling Amps
8.6
11.6
4.4 - 4.7
5.6 - 6.0
115
115
230 -208
230 -208
Parallel
Parallel
Tandem
Tandem
15 amp
15 amp
15 amp
15 amp
Power Cord Type
LCDI
LCDI
LCDI
LCDI
Power Cord length
8 feet
8 feet
6 feet
6 feet
41 oz./hr
55 oz./hr
41 oz./hr
55 oz./hr
275
275
275
275
3 Speed
3 Speed
3 Speed
3 Speed
64° - 86°
64° - 86°
64° - 86°
64° - 86°
PBWS01A
PBWS01A
PBWS01A
PBWS01A
Condensate Drain Spout
Yes on Outercase
Yes on Outercase
Yes on Outercase
Yes on Outercase
Thermostatic Drain Valve
Yes
Yes
Yes
Yes
---
---
---
---
26" TTW
26" TTW
26" TTW
26" TTW
15.625"
15.625"
15.625"
15.625"
Chassis Width
26"
26"
26"
26"
Chassis Depth
16.875"
16.875"
16.875"
16.875"
Cooling (BTU's)
Voltage
Plug Type
Power Cord Rating
Dehumidification: pints / hour
Fan Speeds
CFM cooling : High-Low
Fan Only Speed
Controls
Thermostat temp. range
Outercase : insulation panels
Adjustable changeover thermostat
Chassis Size
Chassis Heighth
5
SPECIFICATIONS
MODEL
PBE***E00AX
PBE093E35AX
PBE123E35AX
9200
8900
11800
11400
9.8
9.8
Cooling Watts
940 - 910
1200 - 1160
Cooling Amps
4.4 - 4.7
5.6 - 6.0
11000 - 9000
11000 - 9000
Electric Heat Watts
3500 - 2900
3500 - 2900
Electric Heat Amps
15 / 14
15 / 14
---
---
Heatpump Watts
---
---
Heatpump Amps
---
---
64 Indoor
64 Indoor
123 Outdoor
123 Outdoor
230 -208
230 -208
Perpendicular
Perpendicular
20 amp
20 amp
Power Cord Type
LCDI
LCDI
Power Cord length
6 feet
6 feet
41 oz./hr
55 oz./hr
265/-
265/-
3 Speed
3 Speed
64° - 86°
64° - 86°
PBWS01A
PBWS01A
Condensate Drain Spout
Yes on Outercase
Yes on Outercase
Thermostatic Drain Valve
Yes
Yes
---
---
26"
26"
15.625"
15.625"
Chassis Width
26"
26"
Chassis Depth
16.875"
16.875"
Cooling (BTU's)
@ EER
Electric Heat
Heatpump
Fan Watts Indoor
Fan Watts Outdoor
Voltage
Plug Type
Power Cord Rating
Dehumidification: pints / hr.
Fan Speeds
CFM cooling : High-Low
Fan Only Speed
Controls
Thermostat temp. range
Outercase : insulation panels
Adjustable changeover thermostat
Chassis Size
Chassis Heighth
6
SPECIFICATIONS
MODEL
PBH***E00AX
PBH092E12AX
PBH093E35AX
PBH113E35AX
9000
9000
8700
11500
11100
@ EER
9.4
9.4
9.4
Cooling Watts
960
960 - 930
1220 - 1180
Cooling Amps
8.8
4.5 - 4.8
5.7 - 6.2
3900
11000 - 9000
11000 - 9000
Electric Heat Watts
1150
3500 - 2900
3500 - 2900
Electric Heat Amps
11
15 / 14
15 / 14
8500
8500
8200
11000
10700
@ C.O.P.
2.9
2.9
2.7
Heatpump Watts
860
860 - 830
1195 - 1160
Heatpump Amps
7.7
4.0 - 4.2
5.2 - 5.6
64 Indoor
64 Indoor
64 Indoor
123 Outdoor
123 Outdoor
123 Outdoor
115
230 -208
230 -208
Parallel
Perpendicular
Perpendicular
15 amp
20amp
20amp
Power Cord Type
LCDI
LCDI
LCDI
Power Cord length
8 feet
6 feet
6 feet
41 oz./hr
41 oz./hr
55 oz./hr
265/-
265/-
265/-
3 Speed
3 Speed
3 Speed
64° - 86°
64° - 86°
64° - 86°
PBWS01A
PBWS01A
PBWS01A
Condensate Drain Spout
Yes on Outercase
Yes on Outercase
Yes on Outercase
Thermostatic Drain Valve
Yes
Yes
Yes
Adjustable changeover thermostat
Yes
Yes
Yes
26"
26"
26"
15.625"
15.625"
15.625"
Chassis Width
26"
26"
26"
Chassis Depth
16.875"
16.875"
16.875"
Cooling (BTU's)
Electric Heat
Heatpump (BTU's)
Fan Watts Indoor
Fan Watts Outdoor
Voltage
Plug Type
Power Cord Rating
Dehumidification: pints / hr.
Fan Speeds
CFM cooling : High-Low
Fan Only Speed
Controls
Thermostat temp. range
Outercase : insulation panels
Chassis Size
Chassis Heighth
7
MODEL
PBC093
8
PBC123
73
67
61
73
67
61
ID WB
ENT
13930
85
14290
75
14120
12315
85
80
12520
12660
75
80
11410
85
11175
75
11130
10765
85
80
10905
11030
75
80
9560
85
9815
75
9720
8775
85
80
8630
8675
75
80
TOTAL
BTUH
ID DB
ENT
7950
6510
5070
9750
8290
6895
11410
10140
11175
6140
5045
3950
7575
6510
5265
8775
7675
6555
SEN
BTUH
85
57
46
35
79
66
54
100
91
100
57
46
36
79
67
54
100
89
76
SHR
13165
13335
13515
11705
11800
12100
10880
10495
10535
10190
10335
10450
9120
9200
9375
8420
8195
8230
TOTAL
BTUH
7670
6220
4780
9500
7990
6660
10880
9825
8370
5930
4835
3735
7445
6085
5065
8420
7450
6335
SEN
BTUH
95
58
47
35
81
68
55
100
94
79
58
47
36
82
66
54
100
91
77
SHR
OUTDOOR TEMP
12265
12530
12725
10820
11025
11230
10230
9750
9810
9575
9725
9860
8505
8650
8760
8050
7720
7745
TOTAL
BTUH
PBC "E" MODEL 230V
7375
5930
4495
9160
7675
6300
10230
9465
8035
5710
4615
3520
7170
5875
4860
8050
7210
6100
SEN
BTUH
105
60
47
35
85
70
56
100
97
82
60
47
36
84
68
55
100
93
79
SHR
11260
11535
11825
9915
10130
10365
9540
8875
8770
8940
9095
9235
7970
8080
8185
7630
7330
7235
TOTAL
BTUH
7000
5580
4175
8825
7345
5950
9540
9055
7645
5485
4390
3295
6745
5595
4760
7630
7330
5860
SEN
BTUH
115
62
48
35
89
73
57
100
102
87
61
48
36
85
69
58
100
100
81
SHR
PERFORMANCE DATA
PBC***E00AX
MODEL
PBC093
PBC123
73
67
61
73
67
61
13530
85
13890
75
13720
11915
85
80
12120
12260
75
80
11010
85
10775
75
10730
10465
85
80
10605
10730
75
80
9260
85
9515
75
9420
8475
85
80
8330
8375
TOTAL
BTUH
80
75
ID WB ID DB
ENT
ENT
7550
6110
4670
9350
7890
6495
11010
9740
10775
5840
4745
3650
7275
6210
4965
8475
7375
6255
SEN
BTUH
85
56
45
34
78
65
53
100
91
100
56
45
34
79
66
52
100
89
75
SHR
12765
12935
13115
11305
11400
11700
10480
10095
10135
9890
10035
10150
8820
8900
9075
8120
7895
7930
TOTAL
BTUH
7270
5820
4380
9095
7590
6260
10480
9425
7970
5630
4535
3435
7145
5785
4765
8120
7150
6035
SEN
BTUH
95
57
45
33
80
67
53
100
93
79
57
45
34
81
65
53
100
91
76
SHR
11865
12130
12325
10420
10625
10830
9830
9350
9410
9275
9425
9560
8205
8350
8460
7750
7420
7445
TOTAL
BTUH
PBE "E" MODEL 208V
6975
5530
4095
8760
7275
5900
9830
9065
7635
5410
4315
3220
6870
5575
4560
7750
6910
5800
SEN
BTUH
105
59
46
33
84
68
54
100
97
81
58
46
34
84
67
54
100
93
78
SHR
10860
11135
11425
9515
9730
9965
9140
8475
8370
8640
8795
8935
7676
7780
7885
7330
7030
6935
TOTAL
BTUH
6600
5180
3775
8420
6945
5550
9140
8655
7245
5185
4090
2995
6445
5295
4460
7330
7030
5560
SEN
BTUH
115
61
47
33
89
71
56
100
102
87
60
47
34
84
68
57
100
100
80
SHR
PERFORMANCE DATA
PBC***E00AX
9
MODEL
PBE092
10
PBE123
73
67
61
73
67
61
ID WB
ENT
14120
13930
85
14290
75
80
12315
85
12660
75
12520
11410
85
80
11130
11175
75
80
10765
85
11030
10905
75
80
9560
85
9815
75
9720
8775
85
80
8630
8675
75
80
TOTAL
BTUH
ID DB
ENT
7950
6510
5070
9750
8290
6895
11410
10140
11175
6140
5045
3950
7575
6510
5265
8775
7675
6555
SEN
BTUH
85
57
46
35
79
66
54
100
91
100
57
46
36
79
67
54
100
89
76
SHR
13165
13335
13515
11705
11800
12100
10880
10495
10535
10190
10335
10450
9120
9200
9375
8420
8195
8230
TOTAL
BTUH
7670
6220
4780
9500
7990
6660
10880
9825
8370
5930
4835
3735
7445
6085
5065
8420
7450
6335
SEN
BTUH
95
58
47
35
81
68
55
100
94
79
58
47
36
82
66
54
100
91
77
SHR
OUTDOOR TEMP
12265
12530
12725
10820
11025
11230
10230
9750
9810
9575
9725
9860
8505
8650
8760
8050
7720
7745
TOTAL
BTUH
PBE "E" MODEL 230V
7375
5930
4495
9160
7675
6300
10230
9465
8035
5710
4615
3520
7170
5875
4860
8050
7210
6100
SEN
BTUH
105
60
47
35
85
70
56
100
97
82
60
47
36
84
68
55
100
93
79
SHR
11260
11535
11825
9915
10130
10365
9540
8875
8770
8940
9095
9235
7970
8080
8185
7630
7330
7235
TOTAL
BTUH
7000
5580
4175
8825
7345
5950
9540
9055
7645
5485
4390
3295
6745
5595
4760
7630
7330
5860
SEN
BTUH
115
62
48
35
89
73
57
100
102
87
61
48
36
85
69
58
100
100
81
SHR
PERFORMANCE DATA
PBE***E00AX
MODEL
PBE093
PBE123
73
67
61
73
67
61
13530
85
13890
75
13720
11915
85
80
12120
12260
75
80
11010
85
10775
75
10730
10465
85
80
10605
10730
75
80
9260
85
9515
75
9420
8475
85
80
8330
8375
TOTAL
BTUH
80
75
ID WB ID DB
ENT
ENT
7550
6110
4670
9350
7890
6495
11010
9740
10775
5840
4745
3650
7275
6210
4965
8475
7375
6255
SEN
BTUH
85
56
45
34
78
65
53
100
91
100
56
45
34
79
66
52
100
89
75
SHR
12765
12935
13115
11305
11400
11700
10480
10095
10135
9890
10035
10150
8820
8900
9075
8120
7895
7930
TOTAL
BTUH
7270
5820
4380
9095
7590
6260
10480
9425
7970
5630
4535
3435
7145
5785
4765
8120
7150
6035
SEN
BTUH
95
57
45
33
80
67
53
100
93
79
57
45
34
81
65
53
100
91
76
SHR
11865
12130
12325
10420
10625
10830
9830
9350
9410
9275
9425
9560
8205
8350
8460
7750
7420
7445
TOTAL
BTUH
PBE "E" MODEL 208V
6975
5530
4095
8760
7275
5900
9830
9065
7635
5410
4315
3220
6870
5575
4560
7750
6910
5800
SEN
BTUH
105
59
46
33
84
68
54
100
97
81
58
46
34
84
67
54
100
93
78
SHR
10860
11135
11425
9515
9730
9965
9140
8475
8370
8640
8795
8935
7676
7780
7885
7330
7030
6935
TOTAL
BTUH
6600
5180
3775
8420
6945
5550
9140
8655
7245
5185
4090
2995
6445
5295
4460
7330
7030
5560
SEN
BTUH
115
61
47
33
89
71
56
100
102
87
60
47
34
84
68
57
100
100
80
SHR
PERFORMANCE DATA
PBE***E00AX
11
12
MODEL
PBH092
73
67
61
ID WB
ENT
10545
85
10810
75
10680
9345
85
80
9505
80
9620
8485
85
75
8425
8490
75
80
TOTAL
BTUH
ID DB
ENT
5930
4905
3875
7285
6090
5105
8485
7375
6320
SEN
BTUH
85
56
46
36
78
64
53
100
88
74
SHR
9975
10120
10250
8910
9000
9160
8120
7985
8040
5720
4695
3665
7145
5860
4975
8120
7145
6100
57
46
36
80
65
54
100
89
76
OUTDOOR TEMP
SEN
TOTAL
SHR
BTUH
BTUH
95
9365
9515
9650
8295
8450
8560
7725
7515
7550
TOTAL
BTUH
PBH "E" MODEL 115V
5500
4475
3445
6870
5685
4700
7725
6905
5860
SEN
BTUH
105
59
47
36
83
67
55
100
92
78
SHR
8735
8890
9035
7720
7875
7985
7305
7010
7055
TOTAL
BTUH
5275
4250
3220
6600
5370
4600
7305
6990
5620
SEN
BTUH
115
60
48
36
85
68
58
100
100
80
SHR
PERFORMANCE DATA
PBH***E00AX
MODEL
PBH093
PBH123
73
67
61
73
67
61
ID WB
ENT
13580
85
13930
75
13760
12000
85
80
12200
12335
75
80
11120
85
10890
75
10850
10545
85
80
10680
10810
75
80
9345
85
9620
75
9505
8485
85
80
8425
8490
75
80
TOTAL
BTUH
ID DB
ENT
7750
6345
4945
9500
8080
6720
11120
9880
8450
5930
4905
3875
7285
6090
5105
8485
7375
6320
SEN
BTUH
85
57
46
35
79
66
54
100
91
78
56
46
36
78
64
53
100
88
74
SHR
12830
12995
13170
11405
11500
11790
10605
10230
10265
9975
10120
10250
8910
9000
9160
8120
7985
8040
TOTAL
BTUH
7575
6065
4660
9255
7785
6490
10605
9575
8155
5720
4695
3665
7145
5860
4975
8120
7145
6100
SEN
BTUH
95
58
47
35
81
68
55
100
94
79
57
46
36
80
65
54
100
89
76
SHR
OUTDOOR TEMP
11950
12210
12400
10545
10745
10940
9970
9500
9560
9365
9515
9650
8295
8450
8560
7725
7515
7550
TOTAL
BTUH
PBH "E" MODEL 230V
7190
5780
4380
8930
7480
6140
9970
9225
7830
5500
4475
3445
6870
5685
4700
7725
6905
5860
SEN
BTUH
105
60
47
35
85
70
56
100
97
82
59
47
36
83
67
55
100
92
78
SHR
10975
11240
11525
9660
9870
10100
9300
8825
8720
8735
8890
9035
7720
7875
7985
7305
7010
7055
TOTAL
BTUH
6820
5440
4070
8600
7160
5800
9300
8825
7450
5275
4250
3220
6600
5370
4600
7305
6990
5620
SEN
BTUH
115
62
48
35
89
73
57
100
100
85
60
48
36
85
68
58
100
100
80
SHR
PERFORMANCE DATA
PBH***E00AX
13
MODEL
PBH093
14
PBH123
73
67
61
73
67
61
13180
85
13530
75
13360
11600
85
80
11800
11935
75
80
10720
85
10490
75
10450
10245
85
80
10380
10510
75
80
9045
85
9320
75
9205
8185
85
80
8125
8190
TOTAL
BTUH
80
75
ID WB ID DB
ENT
ENT
7350
5945
4545
9100
7680
6320
10720
9480
8050
5630
4605
3575
6985
5790
4805
8185
7075
6020
SEN
BTUH
85
56
45
34
78
65
53
100
91
77
55
44
34
77
63
52
100
87
74
SHR
12430
12595
12770
11005
11100
11390
10200
9830
9865
9675
9820
9950
8610
8700
8860
7820
7685
7740
TOTAL
BTUH
7075
5665
4260
8855
7385
6090
10205
9175
7755
5420
4395
3365
6845
5560
4675
7820
6845
5800
SEN
BTUH
95
57
45
33
80
67
53
100
93
79
56
45
34
80
64
53
100
89
75
SHR
11550
11810
12000
10145
10345
10540
9570
9100
9160
9065
9215
9350
7995
8150
8260
7425
7215
7250
TOTAL
BTUH
PBH "E" MODEL 208V
6790
5380
3980
8530
7080
5740
9570
8825
7430
5200
4175
3145
6570
5385
4400
7425
6605
5560
SEN
BTUH
105
59
46
33
84
68
54
100
97
81
57
45
34
82
66
53
100
92
77
SHR
10575
10840
11125
9260
9470
9700
8900
8425
8320
8435
8590
8735
7420
7575
7685
7005
6710
6755
TOTAL
BTUH
6420
5040
3670
8200
6760
5400
8900
8425
7050
4975
3950
2920
6300
5070
4300
7005
6690
5320
SEN
BTUH
115
61
46
33
89
71
56
100
100
85
59
46
33
85
67
56
100
100
79
SHR
PERFORMANCE DATA
PBH***E00AX
WIRING DIAGRAMS
PBC***E00AX
115V units:C2=4uF,C3=15uF
pt39,42;230V units:C2=1.5uF or
2.5uF,C3=2.5uF
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
II
I
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
15
WIRING DIAGRAMS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
II
I
115V units:C2=4uF,C3=15uF
pt39,42;230V units:C2=1.5uF or
2.5uF,C3=2.5uF
WARNING
PBE***E35AX
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
16
WIRING DIAGRAMS
PBH***E35AX
II
115V units:C2=4uF,C3=15uF
pt39,42;230V units:C2=1.5uF or
2.5uF,C3=2.5uF
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
I
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
17
TROUBLESHOOTING
CODE
STATUS
C OR R E CT IVE ACT IO N
1
F1
Outdoor ambient thermostat
not registering on the board.
R eplace or re-connect the thermostat
2
F2
Outdoor ambient thermostat
not registering on the board.
R eplace or re-connect the thermostat
3
F4
Outdoor c oil thermostat
not registering on the board
R eplace or re-connect the thermostat
4
FJ
Indoor discharge thermostat
not registering on the board
R eplace or re-connect the thermostat