ELECTRICAL CONTROL PANELS & EQUIPMENT FOR ALL TYPES OF ENVIRONMENTS UL PANEL SHOP ESTABLISHED 1969 About Us Since 1969, our team has served the electrical industry, specializing in electrical equipment for the most demanding of applications and environments. In our 30,000 square foot facility, centrally located in “the oil country” heartland of Tulsa, Oklahoma, we operate an NNNY/UL/CUL listed, ISO 9001:2008 panel shop dedicated to providing high quality customer service and products. Our expertise in NEMA 7 controls for hazardous locations is unsurpassed in the industry. We have built a team of drilled and tapped and populated cast products. disconnects, panelboards, purge units and other custom panels of all sizes. We also provide outsourcing services for OEMs who need control panels as a part of their overall system. As Adalet’s largest stocking distributor, we maintain a broad inventory of NEMA7 operators, cast junction boxes, motor control and panel board enclosures ready for immediate customization and shipping. Our immediate access to high quality electrical distribution and control products from vendors such as Cutler Hammer & Allen Bradley also enhances our quick turn around capabilities. When you need customized hazardous location controls, call the experts; we can help convert your questions into immediate solutions. Contacts William Drotar Walt Kosty Sales Inquiries President Operations Manager sales@nema7.com TOLL FREE: 800.739.9145 • PHONE: 918.665.6888 • FAX: 918.663.8615 NORBERG-IES 4237 S. 74th E. Ave Tulsa OK 74127 www.nema7.com 1 CONTENTS also assist you with instrument housings, spin top, stainless steel, increased safety and ATEX enclosures from the Adalet product line. Lighting & Power Distribution Panels......................................................3-4 Circuit Breaker Enclosures.........................................................................5-6 NEMA 7 Fused & Non-Fused Disconnects.................................................7 NEMA 4X Fusible & Non-Fused Disconnects............................................8 Combination & Across the Line Starters................................................9-10 MS 2000 • Manual Motor Starter................................................................11 Explosion Proof Enclosures...................................................................12-14 Explosion Proof Control Stations...............................................................15 Explosion Proof Control Enclosures..........................................................16 NEMA 7 Selector Switches..........................................................................17 NEMA 7 Pilot Lights & Push Buttons........................................................18 Explosion Proof Flexible Couplings...........................................................19 Explosion Proof Fittings...............................................................................20 Custom Control Panels................................................................................21 Factory-Sealed Panelboards........................................................................22 Switchracks...................................................................................................23 We’re committed to providing premium services on explosion proof electrical equipment at competitive pricing, and we back our commitment with an in-stock inventory that is one of the largest in the United States. Our services include: • Complete wiring and assembly of electrical components per UL standards • Turn-key solutions from design to delivery, including CAD capabilities • Expedited services available on in-stock items 2 PANELBOARDS LIGHTING AND POWER DISTRIBUTION PANELS FEATURES • Copper free cast aluminum alloy • Same housings as Adalet XCE enclosures • Cutler Hammer chassis copper buss with ground & isolated neutral bars • Cutler Hammer bolt-on magnetic breakers (optional adder) • Spring loaded breaker handles allow closing of cover with breaker toggle in any position (optional adder) CERTIFICATIONS Class I, Groups B, C & D Class II, Groups E, F & G Class III UL 1203 Type 4, 7, 9 UL 50 CSA C22.2 No. 25 &30 ENCLOSURE DIMENSIONS Part Number Description (A) Description (B) Box Size Voltage XPB121L2 Lighting Panel · 12 Circuit Single Phase, Three Wire · 225 Main Lug Only A 120/240 XPB181L2 Lighting Panel · 18 Circuit Single Phase, Three Wire · 225 Main Lug Only B 120/240 XPB241L2 Lighting Panel · 24 Circuit Single Phase, Three Wire · 225 Main Lug Only B 120/240 XPB243L2 Lighting Panel · 24 Circuit Three Phase, Four Wire · 225 Main Lug Only B 120/208 XPB301L2 Lighting Panel · 30 Circuit Single Phase, Three Wire · 225 Main Lug Only D 120/240 XPB303L2 Lighting Panel · 30 Circuit Three Phase, Four Wire · 225 Main Lug Only D 120/208 XPB361L2 Lighting Panel · 36 Circuit Single Phase, Three Wire · 225 Main Lug Only D 120/240 XPB363L2 Lighting Panel · 36 Circuit Three Phase, Four Wire · 225 Main Lug Only D 120/208 Power Distribution Panel · 24 Circuit Three Phase, Four Wire · 225 Main Lug Only D 277/480 XPBD243L2 BREAKER OPERATOR HANDLES Part Number Description BRANCH CIRCUIT BREAKERS *Breaker Style Part Number Voltage XPB1-H1 Operator for single pole BAB breaker SINGLE POLE BAB 1010 - BAB 1070 120/240 XPB1-H2 Operator for two pole BAB breaker TWO POLE BAB 2010 - BAB 2100 120/240 XPB1-H3 Operator for three pole BAB breaker THREE POLE BAB 3010H - BAB 3100H XPB2-H1 Operator for 1,2 or 3-pole GHB breaker 240 *Breakers are sold installed in panelboard only NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 3 PANELBOARDS LIGHTING AND POWER DISTRIBUTION PANELS PANELBOARD ENCLOSURE DIMENSIONS Box Box Inside Dimensions Mtg Width Mtg Height Overall Cover Overall Cover Overall Each Size W L D (A) (B) (C) (D) (E) A 16 16 6 19¾ 11 20⅞ 20⅞ 11 B 16 24 6 19¾ 18⅜ 20⅞ 28⅞ 11½ D 16 34 6 19¾ 27 20½ 38½ 10¾ CONDUIT ENTRIES Box Size 1/2” 1’ 2” 3” (1) ― (1) ― Top A B D Side ― (2) ― ― Bottom (1) (8) ― ― Top (1) ― (1) ― Side ― (2) ― ― Bottom (1) (8) ― ― Top (1) ― ― (1) Side ― (2) ― ― Bottom (1) (10) ― ― ENCLOSURE CONDUIT DIMENSIONS Box Size F G H J K L M N Weight (lbs.) A 1¾ 3¾ 4¾ 2⅜ 3⅝ 1 3½ 2½ 160 B 1¾ 3¾ 4¾ 2⅜ 3⅝ 3 5 2½ 220 D 2 4 415/16 215/16 413/16 8 11 2½ 285 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 4 CIRCUIT BREAKER ENCLOSURES EXPLOSION PROOF CIRCUIT BREAKER ENCLOSURES Standard XBO Style Optional XCBH Style Spring loaded, compact design. “Classic” larger handle. Easier to assemble and less expensive. 1” - 11 1/2” NPSM opening required for installation. 3/4” - 14 NPSM opening required for installation. Optional XCBH style handle shown; standard handle is XBO. ENCLOSURE • FEATURES • Housings are copper free aluminum alloy • Furnished with stainless steel captive cover bolts • For XCBA & XCBB hinge and mounting pan are optional, XCBC and larger are furnished with hinges CERTIFICATIONS Class I, Groups B*, C & D Class II, Groups E, F & G Class III Type 4X (w/SS cover bolts) UL 1203 CSA C22.2 No. 25 &30 BREAKER FRAME STYLES • Cutler Hammer thermal magnetic type circuit breakers • Frame sizes range from 15 to 600 amp as follows: • F Frame: 15 - 100 Amp Range • JD Frame: 70 - 250 Amp Range • KD Frame: 70 - 400 Amp Range • LD Frame: 125 - 600 Amp Range • Short circuit and overload protection must be provided by a separate protection device • Available with two pole or three pole breakers NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 5 CIRCUIT BREAKER ENCLOSURES EXPLOSION PROOF CIRCUIT BREAKER ENCLOSURES CIRCUIT BREAKER ENCLOSURE ONLY Breaker Enclosure Trip Range Frame Size XCBA-N4 100 15 - 70 XCBB-N4 100/150 80 - 150 XCBC-N4 225/250 70 - 250 XCBD-N4 400 250 - 400 XCBE-N4 600 400 - 800 *XCBF-N4 800 800 - 1200 * Not a standard catalog item All enclosures have a 1/2” NPT on top and bottom for installation of breather drain. TO ORDER: Specify breaker trip range for your application. ENCLOSURE DATA DIMENSIONS Enclosure Part # Inside Nom. Dimensions Overall Dimensions Mounting CL to CL Mtg Conduit Dimensions Conduit W L D A B C Lug E Lug F Bolt Size D G Size # Holes XCBA-N4 6 11 5 9 1/4 14 1/4 9 9 1/8 7 1/2 7/16” 2 1/2 ― 1 1/4 1 XCBB-N4 6 13 5 9 1/4 16 1/4 9 9 1/8 8 1/2 3/8” 2 1/2 ― 2 1 XCBC-N4 7 18 5 10 3/8 21 5/8 9 9 3/4 14 1/2 3/8” 2 3/4 ― 2 1/2 1 XCBD-N4 12 20 5 16 1/4 24 1/4 10 15 3/4 14 3/8 1/2” 3 1/4 ― 2 1/2 1 XCBE-N4 12 24 6 16 1/4 28 1/4 11 15 3/4 18 3/8 1/2” 3 5/8 2 7/8 3 2 XCBF-N4 12 36 8 16 1/4 40 1/4 13 1/2 15 3/4 29 5/8” 4 1/2 3 3/8 4 2 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 6 NEMA 7 DISCONNECT S FUSIBLE & NON-FUSED DISCONNECTS NEMA 7 DISCONNECTS FEATURES & OPTIONS • Housings are copper free aluminum alloy with stainless steel captive cover bolts • Front mounted XBO style handle, padlockable in either “on” or • Cutler Hammer DS style toggle disconnects installed • Fusible disconnects include (3) current limiting Class J fuses • 400 and 600 amp range disconnects are available on special request • Breather/Drains are added upon request for additional charge ENCLOSURE DATA DIMENSIONS Disconnect Part # XPND30 N4 Inside Nom. Dimensions Overall Dimensions Mounting CL to CL Mtg Conduit Dimensions Conduit W L D A B C Lug E Lug F Bolt Size D G Size # Holes 6 11 5 9 1/4 14 1/4 9 9 1/8 7 1/2 7/16” 2 1/2 ― 1 1/4 1 XPFD30 N4 6 11 5 9 1/4 14 1/4 9 9 1/8 7 1/2 7/16” 2 1/2 ― 1 1/4 1 XPND60 N4 6 11 5 9 1/4 14 1/4 9 9 1/8 7 1/2 7/16” 2 1/2 ― 1 1/4 1 XPFD60 N4 6 11 5 9 1/4 14 1/4 9 9 1/8 7 1/2 7/16” 2 1/2 ― 1 1/4 1 XPND100 N4 6 13 5 9 1/4 16 1/4 9 9 1/8 8 1/2 3/8” 2 1/2 ― 2 1 XPFD100 N4 6 13 5 9 1/4 16 1/4 9 9 1/8 8 1/2 3/8” 2 1/2 ― 2 1 XPND200 N4 7 18 5 10 3/8 21 5/8 9 9 3/4 14 1/2 3/8” 2 3/4 ― 2 1/2 1 XPFD200 N4 12 24 6 16 1/4 28 1/4 11 15 3/4 18 3/8 1/2” 3 5/8 2 7/8 3 2 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 7 NEMA 4X DISCONNECTS FUSIBLE & NON-FUSED DISCONNECTS NEMA 4X DISCONNECTS FEATURES & OPTIONS • Our disconnect switches are UL 98 rated and are fully assembled in a NEMA4X enclosure with a front operated padlockable handle. a continuous stainless steel piano hinge and clamping hardware. It is sealed with neoprene gasket for protection in wet environments. disconnects, and come standard with visible blade contacts. • Fusible disconnects include (3) current limiting Class J fuses • Larger amp range disconnect switches are available on special request ENCLOSURE DATA DIMENSIONS Box Dimensions Disconnect Part # W L SSND30 N4 10 8 Mtg Disconnect Fuse D Pan Ampere Style 6 10P08 30 N/A SSFD30 N4 10 8 6 10P08 30 Class J SSND60 N4 10 8 6 10P08 60 N/A SSFD60 N4 10 8 6 10P08 60 Class J SSND100 N4 12 12 6 12P12 100 N/A SSFD100 N4 12 12 6 12P12 100 Class J SSND200 N4 12 12 6 12P12 200 N/A SSFD200 N4 12 12 6 12P12 200 Class J FUSED & NON-FUSED DISCONNECT SWITCHES APPROVALS All switches meet the requirements of UL98 Socomec also has the following approvals UL Listed - Guide WPZX - File E191605 CSA C22.2 #4 Classs 4652 04, File 703166 SOCOMEC NEMA 4X Fusible & Non-Fusible Disconnect Switches IEC 947-3 - CE Mark CUTLER HAMMER NEMA 7 Fusible & Non-Fusible Disconnect Switches NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 8 EXPLOSION PROOF MOTOR CONTROL EXPLOSION PROOF MOTOR STARTERS SIZING THE STARTER Max. UL Horsepower STARTER SIZE AMP RATING 3-Phase 208V 240V 480V 600V SIZE 00 9 1 1/2 1 1/2 2 2 SIZE 0 18 3 3 5 5 SIZE 1 27 7 1/2 7 1/2 10 10 SIZE 2 45 10 15 25 25 SIZE 3 90 25 30 50 50 SIZE 4 135 40 50 100 100 SIZE 5 270 75 100 200 200 SIZE 6 540 150 200 400 400 COMBINATION STARTERS COMBINATION STARTERS Standard features include: STD. BREAKER FRAME SIZE ENCLOSURE • Adjustable reset button SIZE 0 100 XCBSAQ-N4 • Lockable cast aluminum breaker handle SIZE 1 100 XCBSAQ-N4 • Two predrilled operator holes for pilot devices SIZE 2 100 XCBSBQ-N4 SIZE 3 100 XCBSLQ-N4 SIZE 4 225/250 XCBSMQ-N4 SIZE 5 400 STARTER SIZE XCBSN-N4 CERTIFICATIONS Class I, Groups B*, C & D Class II, Groups E, F & G Class III UL 1203 CSA C22.2 No. 25 &30 • N4 gasket & captive stainless steel cover bolts Options: • Populated with either NEMA or IEC style components (NEMA - Cutler Hammer • IEC - Specher+Schuh) • Type of auxillary device (Pg 17, 18 for options) • Installation of auxillary devices • Nameplates and contacts for auxillary devices • Control transformer w/fuseblocks • Overload heaters • Internal control wiring Type 4X (w/SS cover bolts) • Breather/Drain ACROSS THE LINE ACROSS THE LINE STARTERS STARTER SIZE ENCLOSURE SIZE 0 XMSB-N4 SIZE 1 XMSB-N4 SIZE 2 XMSD-N4 Options: SIZE 3 XMSH-N4 • Same options available as combination starter except no breaker SIZE 4 XMSH-N4 SIZE 5 XMSQ-N4 • Populated with either NEMA or IEC style components (NEMA - Cutler Hammer • IEC - Specher+Schuh) Standard features include: • Same features as combination starter except no breaker handle NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 9 EXPLOSION PROOF MOTOR CONTROL EXPLOSION PROOF MOTOR STARTERS C 1 3 4 C 3 1 4 RESET OFF TRIPPED ON C OFF 3 1 4 ON D B MTG B ESE D B ESE ESE ESE ESE R T T R R T T R R T T R D ESE 5 2 6 5 2 6 5 2 6 E E 5 E F 2 5 A F 2 F 2 A FIGURE A 6 A FIGURE B FIGURE C DIMENSIONS FOR EXPLOSION PROOF MOTOR STARTERS Inside Nom. Dimensions Enclosure Fig # W L D Nominal Dimensions in inches A B C D E Conduit F G Size XCBSAQ-N4 A 6 23 5 4 1/8 25 1/2 11 1/8 26 15/16 9 11/16 2 1/2 3&5 1 1/2 XCBSBQ-N4 A 7 27 6 4 3/4 29 7/8 11 13/16 31 1/8 10 1/2 2 13/16 3&5 1 1/2 XCBSLQ-N4 B 12 24 8 15 3/4 18 3/8 16 15/16 28 1/4 12 15/16 3 3&5 2 XCBSMQ-N4 B 12 36 8 15 3/4 29 16 15/16 40 1/4 13 3/8 3 5/8 3&5 2 1/2 XCBSN-N4 B 16 46 10 19 3/4 39 21 3/4 50 7/8 16 7/16 4 7/8 3&5 4 XMSB C 8 10 6 10 3/4 6 1/2 12 13 3/8 8 1/4 2 3/8 3&6 1 XMSD C 10 14 6 13 10 5/8 14 17 3/8 8 3/8 2 3/4 3&6 1 1/2 XMSH C 12 18 8 15 3/4 14 1/8 17 22 1/4 10 3/4 3 1/2 3&6 2 1/2 XMSQ C 18 36 10 21 3/4 29 23 3/4 40 7/8 14 7/8 4 5/16 3&6 3 Our combination and across the line starters are available fully wired and assembled using your preference of NEMA or IEC style components. Expedited services are available on some starters. NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 10 MANUAL MOTOR STARTER EXPLOSION PROOF MANUAL MOTOR STARTER MS 2000 • FEATURES & OPTIONS FEATURES: • Cutler Hammer Type XTPB Manual Starter • Red and green pushbuttons for easy start/stop operation • Watertight ‘O’ Ring for NEMA 4X applications OPTIONS: • Auxillary contacts • Breather/Drain • Shunt Trip MS 2000 • STARTER RATING MAXIMUM UL HP 3-PHASE - 480V CURRENT RANGE XIFC-040604-15021-1 * 0.10 - 0.16 XIFC-040604-15021-2 * 0.16 - 0.25 XIFC-040604-15021-3 * 0.25 - 0.40 XIFC-040604-15021-4 1/2 0.40 - 0.63 XIFC-040604-15021-5 1/2 0.63 - 1 XIFC-040604-15021-6 3/4 1 - 1.6 XIFC-040604-15021-7 1 1.6 - 2.5 XIFC-040604-15021-8 2 2.5 - 4 CATALOG PART NUMBER MS 2000 • CERTIFICATIONS Class I, Groups C & D Class II, Groups E, F & G CSA Standard C22.2 No. 30 NEMA 7CD, 9EFG XIFC-040604-15021-9 3 4 - 6.3 XIFC-040604-15021-10 7 1/2 6.3 - 10 XIFC-040604-15021-11 10 10 - 16 XIFC-040604-15021-12 10 16 - 20 XIFC-040604-15021-13 15 20 - 25 *In this range, calculate motor rating according to rated current 6 ½” 2” 4 ¼” MTG. OUTER SLOTS ACCEPT MTG. BOLTS ¾” NPT (TOP/BOTTOM) INNER SLOTS ACCEPT ¼” MTG. BOLTS NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 11 ENCLOSURES EXPLOSION PROOF CONTROL ENCLOSURES XCE SERIES • FEATURES • Copper free aluminum, lightweight & corrosion resistant • High strength steel cover bolts, coated and plated for maximum corrosion resistance (stainless steel optional) • An internal grounding screw is standard a nitrile o-ring to ensure a watertight seal • Enclosures include a steel mounting pan and hinge set ENCLOSURE OPTIONS electrical/electronic components for control, measurement and/or monitoring of applications in hazardous environments. At NEMA7, we specialize in modifying these enclosures to meet your requirements. Our on-site capabilities include conduit drilling and tapping, installation of glass viewing windows, as well as wiring and assembly of a In addition to the XCE series of explosion proof enclosures, the following enclosures are available: • XCEX: Flame proof control enclosures • XCEQ: Explosion proof quad-lead control enclosures NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 12 ENCLOSURES Explosion Proof Control Enclosures XCE Catalog # Inside Nom. Dimensions W L D XCE41604N4 4 16 4 XCE60804N4 6 8 4 Usable Depth Overall Dimensions Mtg Ship Cover Wall C Lug E Lug F Bolt Size Weight lbs Thickness 19 1/4 6 12 1/8 6 3/4 3/8” 25 1/2 11 1/4 5 15/16 4 1/2 9 1/8 3/8” 21 1/2 A B 4 3/4 7 1/4 4 5/8 9 1/4 Mounting CL to CL XCE60805N4 6 8 5 5 5/8 9 1/4 11 1/4 6 15/16 4 1/2 9 1/8 3/8” 23 1/2 XCE60806N4 6 8 6 6 5/8 9 1/4 11 1/4 7 15/16 4 1/2 9 1/8 3/8” 25 1/2 XCE61105N4 6 11 5 5 7/8 9 1/4 14 1/4 7 3/16 7 1/2 9 1/8 3/8” 24 1/2 XCE61204N4 6 12 4 4 3/4 9 1/4 15 1/4 6 1/16 8 1/2 9 1/8 3/8” 24 5/8 XCE61206N4 6 12 6 6 3/4 9 1/4 15 1/4 8 1/16 8 1/2 9 1/8 3/8” 29 5/8 XCE61305N4 6 13 5 5 7/8 9 1/4 16 1/4 7 3/16 9 1/2 9 1/8 3/8” 26 1/2 XCE71004N4 7 10 4 4 3/4 10 3/8 13 3/8 6 3/16 6 1/2 9 3/4 3/8” 27 5/8 XCE71006N4 7 10 6 1/8 6 3/4 10 3/8 13 3/8 8 3/16 6 1/2 9 3/4 3/8” 31 5/8 XCE71805N4 7 18 1/4 5 5 3/4 10 3/8 21 5/8 7 3/16 14 1/2 9 3/4 3/8” 55 5/8 XCE80804N4 8 8 4 4 13/16 11 3/8 11 3/8 6 3/8 4 1/4 11 3/8” 24 11/16 XCE80806N4 8 8 6 6 13/16 11 3/8 11 3/8 8 3/8 4 1/4 11 3/8” 28 11/16 11/16 XCE80808N4 8 8 8 8 13/16 11 3/8 11 3/8 10 3/8 4 1/4 11 3/8” 35 XCE81004N4 8 10 4 4 3/4 11 3/8 13 3/8 6 1/4 6 1/2 10 3/4 3/8” 30 11/16 XCE81006N4 8 10 6 6 3/4 11 3/8 13 3/8 8 1/4 6 1/2 10 3/4 3/8” 34 11/16 XCE81008N4 8 10 8 8 3/4 11 3/8 13 3/8 10 1/4 6 1/2 10 3/4 3/8” 39 11/16 XCE81204N4 8 12 4 4 3/4 11 3/8 15 3/8 6 1/4 8 1/2 10 3/4 3/8” 34 11/16 XCE81206N4 8 12 6 6 3/4 11 3/8 15 3/8 8 1/4 8 1/2 10 3/4 3/8” 42 11/16 XCE81208N4 8 12 8 8 3/4 11 3/8 15 3/8 10 1/4 8 1/2 10 3/4 3/8” 48 11/16 XCE91105N4 9 11 5 5 3/4 12 3/8 14 3/8 7 5/16 7 1/2 12 3/8” 41 11/16 XCE101004N4 10 10 4 4 3/4 13 3/8 13 3/8 6 5/16 6 1/2 13 3/8” 34 11/16 XCE101006N4 10 10 6 6 3/4 13 3/8 13 3/8 8 5/16 6 1/2 13 3/8” 44 11/16 XCE101008N4 10 10 8 8 3/4 13 3/8 13 3/8 10 5/16 6 1/2 13 3/8” 50 11/16 XCE101206N4 10 12 6 1/4 7 1/4 13 3/8 15 3/8 8 7/8 8 1/2 13 3/8” 46 3/4 XCE101404N4 10 14 4 4 3/4 13 3/8 17 3/8 6 7/16 10 5/8 13 3/8” 42 3/4 XCE101406N4 10 14 6 6 3/4 13 3/8 17 3/8 8 7/16 10 5/8 13 3/8” 49 3/4 XCE101408N4 10 14 8 8 3/4 13 3/8 17 3/8 10 1/2 10 5/8 13 1/2” 57 3/4 XCE121204N4 12 12 4 5 16 1/4 16 1/4 6 15/16 8 5/8 16 1/2” 60 7/8 XCE121206N4 12 12 6 7 16 1/4 16 1/4 8 15/16 8 5/8 16 1/2” 68 7/8 XCE121208N4 12 12 8 9 16 1/4 16 1/4 10 15/16 8 5/8 16 1/2” 80 7/8 XCE121804N4 12 18 4 4 3/4 16 1/4 22 1/4 6 3/4 14 1/8 16 1/2” 85 15/16 XCE121806N4 12 18 6 6 3/4 16 1/4 22 1/4 8 3/4 14 1/8 16 1/2” 93 15/16 XCE121808N4 12 18 8 8 3/4 16 1/4 22 1/4 10 3/4 14 1/8 16 1/2” 101 15/16 XCE122005N4 12 20 5 5 3/4 16 1/4 24 1/4 8 1/8 14 3/8 16 1/2” 104 1 1/8 XCE122406N4 12 24 6 6 15/16 16 1/4 28 1/4 9 1/4 18 3/8 16 1/2” 127 1 1/8 XCE122408N4 12 24 8 8 15/16 16 1/4 28 1/4 11 1/4 18 3/8 16 1/2” 142 1 1/8 XCE122410N4 12 24 10 10 15/16 16 1/4 28 1/4 13 1/4 18 3/8 16 1/2” 154 1 1/8 XCE123006N4 12 30 6 6 11/16 16 3/4 34 1/4 9 5/8 23 16 1/2” 180 1 3/8 XCE123606N4 12 36 6 6 15/16 16 1/4 40 1/4 9 11/16 29 16 1/2” 212 1 3/16 XCE123608N4 12 36 8 8 15/16 16 1/4 40 1/4 11 11/16 29 16 1/2” 232 1 3/16 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 13 ENCLOSURES Explosion Proof Control Enclosures XCE Inside Nom. Dimensions Usable Overall Dimensions Mounting CL to CL Mtg Ship Cover Wall Catalog # W L D Depth A B C Lug E Lug F Bolt Size Weight lbs Thickness XCE124608N4 12 46 8 8 15/16 16 1/4 50 1/4 11 11/16 39 16 5/8” 280 1 1/4 XCE141404N4 14 14 4 5 18 1/4 18 1/4 7 1/8 9 3/4 17 3/4 1/2” 91 7/8 XCE141406N4 14 14 6 7 18 1/4 18 1/4 9 1/4 9 3/4 17 3/4 1/2” 97 7/8 XCE141408N4 14 14 8 9 18 1/4 18 1/4 11 1/8 9 3/4 17 3/4 1/2” 103 7/8 XCE142210N4 14 22 10 11 1/4 18 1/4 26 1/4 13 5/8 16 1/2 17 3/4 1/2” 181 1 1/8 XCE142213N4 14 22 10 13 18 1/4 26 1/4 15 1/8 16 1/2 17 3/4 1/2” 235 1 1/8 XCE142806N4 14 28 6 7 13/16 18 1/4 32 1/4 9 9/16 22 1/2 17 3/4 1/2” 120 1 1/8 XCE161606N4 16 16 6 7 5/8 20 7/8 20 7/8 9 15/16 11 19 3/4 5/8” 135 7/8 XCE161608N4 16 16 8 9 5/8 20 7/8 20 7/8 11 15/16 11 19 3/4 5/8” 156 7/8 XCE162406N4 16 24 6 7 13/16 20 7/8 28 7/8 10 3/8 18 3/8 19 3/4 5/8” 190 7/8 XCE162408N4 16 24 8 9 13/16 20 7/8 28 7/8 12 3/8 18 3/8 19 3/4 5/8” 209 7/8 XCE162410N4 16 24 10 11 13/16 20 7/8 28 7/8 14 3/8 18 3/8 19 3/4 5/8” 225 7/8 XCE162806N4 16 28 6 6 13/16 20 1/2 32 11/16 9 1/2 22 1/2 19 3/4 5/8” 200 1 1/4 XCE163406N4 16 34 6 6 15/16 20 1/2 38 1/2 9 1/2 27 19 3/4 5/8” 260 1 1/4 XCE164610N4 16 46 10 11 13/16 20 7/8 50 7/8 14 9/16 39 19 3/4 5/8” 390 1 XCE181804N4 18 18 4 5 13/16 22 7/8 22 7/8 8 1/2 13 21 3/4 5/8” 154 1 XCE181806N4 18 18 6 7 13/16 22 7/8 22 7/8 10 1/2 13 21 3/4 5/8” 177 1 XCE181808N4 18 18 8 9 13/16 22 7/8 22 7/8 12 1/2 13 21 3/4 5/8” 200 1 XCE182406N4 18 24 6 7 7/16 22 7/8 28 7/8 10 13/16 18 3/8 21 3/4 5/8” 226 1 1/2 XCE182408N4 18 24 8 9 7/16 22 7/8 28 7/8 12 13/16 18 3/8 21 3/4 5/8” 239 1 1/2 XCE182410N4 18 24 10 11 7/16 22 7/8 28 7/8 14 13/16 18 3/8 21 3/4 5/8” 260 1 1/2 XCE183008N4 18 30 8 9 3/8 22 7/8 34 7/8 12 13/16 23 21 3/4 5/8” 293 1 1/2 XCE183608N4 18 36 8 9 3/8 22 7/8 40 7/8 12 7/8 29 21 3/4 5/8” 318 1 7/8 XCE183610N4 18 36 10 11 3/8 22 7/8 40 7/8 14 7/8 29 21 3/4 5/8” 340 1 7/8 XCE204806N4 20 48 6 7 1/8 24 7/8 52 7/8 10 7/8 41 24 5/8” 430 1 7/8 XCE242408N4 24 24 8 9 7/16 28 7/8 28 7/8 12 7/16 18 3/8 28 5/8” 302 1 1/2 XCE242410N4 24 24 10 11 7/16 28 7/8 28 7/8 14 7/16 18 3/8 28 5/8” 330 1 1/2 XCE243008N4 24 30 8 9 1/4 28 7/8 34 7/8 12 15/16 23 28 5/8” 356 1 7/8 XCE243608N4 24 36 8 9 1/4 28 7/8 40 7/8 12 7/16 29 28 5/8” 408 1 7/8 XCE243610N4 24 36 10 11 1/4 28 7/8 40 7/8 14 7/8 29 28 5/8” 433 1 7/8 XCE323612N4 32 36 12 12 37 3/4 41 3/4 15 1/2 29 36 1/8 5/8” 691 Factory MOUNTING PANS & HINGES • All enclosures include a steel mounting pan and hinge set • Mounting pans are constructed of 12 gauge galvanized steel and include 1/4” high spacers and stainless steel mounting screws • Hinge sets are made of an extruded aluminum alloy and consist of two sections: female and male with a stainless steel pin and four stainless steel hex head bolts NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 14 CONTROL STATIONS XCE SERIES • CERTIFICATIONS Class I, Groups B, C & D Class II, Groups E, F & G Class III UL 1203 CSA C22.2 No. 25 &30 Type 4X (w/SS cover bolts) For over 40 years we’ve specialized in providing value added products and services on electrical equipment for the most demanding of applications and environments. NEMA 7 CONTROL STATIONS Number Operators Std. Conduit Size (in.) 5 1/2 1 3/4 7 1/16 8 2 3/4 030703 8 1/8 9 3 3/4 X4 030903 10 1/16 11 4 1 X5 031103 12 1/16 13 5 1 1/4 X6 031303 14 1/16 15 6 1 1/4 X7 031503 16 17 7 1 1/4 X8 031803 19 20 8 1 1/4 X12 032403 25 1/16 26 12 1 1/2 X15 033003 31 1/8 32 1/8 15 1 1/2 X18 033603 37 1/4 38 1/8 18 1 1/2 Catalog Number Nominal Inside Dimensions Dimensions A B X1 030303 4 1/2 X2 030603 X3 FEATURES & CERTIFICATIONS • Lightweight, copper free aluminum, corrosion resistant • Operators may be mounted through back wall for panel mounting • For NEMA 4X or special machining see XIFC series • Box depth allows stacking of 2 contact blocks Class I, Groups C & D Class II, Groups E, F & G UL: Standard 698 CSA Standard C22.2 No. 30 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 15 CONTROL ENCLOSURES NEMA 7 CONTROL ENCLOSURES A FEATURES & CERTIFICATIONS W • Copper free aluminum, lightweight & corrosion resistant • Available with steel mounting pan (additional charge) • Available with NEMA 4 “O” Ring (additional charge) B • Flameproof Enclosure with ATEX rating available Class I, Groups B, C & D Class II, Groups E, F & G Class III L F UL 1203 CSA C22.2 No. 25 &30 E C D NEMA 7 CONTROL ENCLOSURES XCE Catalog XIFC030303 Inside Nom. Dimensions Overall Dimensions Mounting CL to CL Mtg W L D A B C Lug E Lug F Bolt Size 3 5/16 3 5/16 3 3/16 4 1/2 4 1/2 4 5/16 3 1/4 5 1/2 5/16 XIFC030603 3 1/4 5 3/4 3 4 1/2 7 1/16 4 1/4 3 1/4 8 5/16 XIFC030703 3 1/4 6 7/8 3 4 1/2 8 1/8 4 5/16 3 5/16 9 5/16 XIFC030903 3 11/32 8 15/16 3 4 1/2 10 1/16 4 5/16 3 1/4 11 5/16 XIFC031103 3 1/4 10 15/16 3 4 1/2 12 4 5/16 3 1/4 13 5/16 XIFC031303 3 1/4 12 13/16 3 4 1/2 14 1/16 4 5/16 3 1/4 15 5/16 XIFC031503 3 1/4 14 3/4 3 1/16 4 1/2 16 4 5/16 3 1/4 17 5/16 XIFC031803 3 1/4 17 3/4 3 4 1/2 19 4 1/4 3 1/4 20 5/16 XIFC032403 3 1/4 23 9/16 3 4 1/2 25 1/16 4 5/16 3 1/4 26 5/16 XIFC033003 3 1/4 29 1/2 3 4 9/16 31 1/16 4 5/16 3 1/4 32 1/8 5/16 XIFC033603 3 1/4 35 7/16 3 4 1/2 37 1/4 4 3/8 3 1/4 38 1/8 5/16 XIFC040604 4 1/8 5 7/8 4 5 3/8 7 5 5/16 4 3/8 8 1/4 5/16 5/16 XIFC041204 4 1/4 11 13/16 4 5 1/2 13 1/8 5 5/16 4 3/8 14 1/4 XIFC060606 5 1/2 5 1/2 6 7 7 7 3/8 5 1/2 8 1/2 3/8 XIFC060608 5 1/4 5 1/2 8 7 7 9 3/8 5 1/2 8 1/2 3/8 XIFC061206 5 1/4 11 1/8 6 7 1/4 13 1/2 7 5/8 5 1/2 15 3/8 XIFC070704 6 7/8 6 7/8 4 7 15/16 7 15/16 5 5/16 6 5/8 9 1/8 3/8 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 16 OPERATORS NEMA 7 PUSH BUTTONS NEMA 7 PILOT LIGHTS Catalog Number Lens Color Operator Description Catalog Number Operator Description Contact Blocks XLA Amber Unguarded Pilot Light - Panel Mount XHPB Panel Mount Push Button Not Included XLSA Amber Unguarded Pilot Light - Surface Mount XHPBS Surface Mount Push Button Not Included XLA-GH Amber Guarded Pilot Light - Panel Mount XHPBM Momentary Stop - Panel Mount - Red Mushroom Head Not Included XLSA-GH Amber Guarded Pilot Light - Surface Mount XHPBMS Momentary Stop - Surface Mount - Red Mushroom Head Not Included XLB Blue Unguarded Pilot Light - Panel Mount XHPBPL Panel Mount Push Button - Padlock Devices Not Included XLSB Blue Unguarded Pilot Light - Surface Mount XHPBSPL Surface Mount Push Button - Padlock Devices Not Included XLB-GH Blue Guarded Pilot Light - Panel Mount XHPPM Maintained Stop - Panel Mount - Red Mushroom Head Included XLSB-GH Blue Guarded Pilot Light - Surface Mount XHPPMS Maintained Stop - Surface Mount - Red Mushroom Head Included XLC Clear Unguarded Pilot Light - Panel Mount XLSC Clear Unguarded Pilot Light - Surface Mount XLC-GH Clear Guarded Pilot Light - Panel Mount • XHPB are momentary pushbuttons XLSC-GH Clear Guarded Pilot Light - Surface Mount • XHPP are maintained pushbuttons XLG Green Unguarded Pilot Light - Panel Mount XLSG Green Unguarded Pilot Light - Surface Mount • Rated for Class I, Groups B, C & D XLG-GH Green Guarded Pilot Light - Panel Mount XLSG-GH Green Guarded Pilot Light - Surface Mount XLR Red Unguarded Pilot Light - Panel Mount XLSR Red Unguarded Pilot Light - Surface Mount XLR-GH Red Guarded Pilot Light - Panel Mount XLSR-GH Red Guarded Pilot Light - Surface Mount XLW White Unguarded Pilot Light - Panel Mount XLSW White Unguarded Pilot Light - Surface Mount XLW-GH White Guarded Pilot Light - Panel Mount XLSW-GH White Guarded Pilot Light - Surface Mount • All pilot lights have 8” leads • Group B applications must use guarded pilot lights • Equipped with 6 watt, 120 volt, 6S6 clear lamps • Alternate lamp voltages available upon request PUSHBUTTON FEATURES • Rated for Class II, Groups E, F & G • Legend plates are available with markings for various applications • Protective boots are available for the XHPB & XHPBS OPERATOR SHANK SIZE Panel mount operators have longer enclosures that have a cover wall thickness of greater than 7/8”. Surface mount operators have shorter shanks and are designed for enclosures with a cover wall thickness of 7/8” or less. Use the tables on pages 12 & 13 to determine the cover wall thickness of enclosures. 17 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 OPERATORS NEMA 7 SELECTOR SWITCHES BT Series Contact Blocks • Can be stacked for up to (4) multiple circuits • Contacts extend 7/8” beyond operator BT Series Contact Blocks Catalog Number Operator Description XHSS Panel Mount 2/3 2/3 Cam # of SS Positions XHSSS Surface Mount XHSC Panel Mount 3 XHSSC Surface Mount 3 XHSR2 Panel Mount 2 2 XHSSR2 Surface Mount 2 2 XHSR Panel Mount 3 XHSSR Surface Mount 3 XHSL2 Panel Mount 4 2 XHSSL2 Surface Mount 4 2 XHSL Panel Mount 3 3 XHSSL Surface Mount BT 1A (1) Open (1) Closed XHSSPL Panel Mount w/padlock device BT1B (1) Closed (1) Open XHSSSPL Surface Mount w/padlock device XHSSL-4P Panel Mount 4 BT2 (2) Open XHSSS-4P Surface Mount 4 BT3 (2) Closed XHSSL-5P Panel Mount 5 BT4 (1) Open XHSSS-5P Surface Mount 5 BT5 (1) Closed • Die cast alumimum alloy. Barrels are 3/4” NPSM thread BT44 (2) Open (2) Closed • Specify 2 or 3 position - For 3 positon specify CAM XHSS Series XHSSS Series • Contact blocks are not included with operators (See below) • All operators have black molded nylon knobs • Protective boots and legend plates are available Selector Switch Operators are rated for: Class I, Groups B, C & D - Class II, Groups E, F, & G • NEMA 3, 4, 7 & 9 CONTACT SEQUENCE CHART Contact Block Number Circuit Cam 1 Contact Sequence Cam 2 Contact Sequence Cam 3 Contact Sequence Cam 4 Contact Sequence Cam 5 Contact Sequence Cam 6 Contact Sequence Normally Closed (NC) Normally Open (NO) BT1A Circuit A Circuit B XO OX OXO OOX OXX OOX XOO OXO OXX XXO XOO OXO Normally Closed (NC) Normally Open (NO) BT1B Circuit B Circuit A XO OX XXO XOX XXO XOO XOX OXX OOX XOO OOX OOX Normally Open (NO) Normally Open (NO) BT2 Circuit A Circuit B OX OX XOX OOX XOO OOX OXX OXO XOO XXO OOX OXO Normally Closed (NC) Normally Closed (NC) BT3 Circuit A Circuit B XO XO OXO XXO OXX XXO XOO XOX OXX OOX XOO OOX Circuit of Contact Block O = Contact Open X = Contact Closed NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 18 EXPLOSION PROOF FLEXIBLE COUPLINGS FLEXIBLE COUPLINGS FEATURES • All sizes are constructed from bronze braided brass tubing and have an arc resistant liner. and two male nipples. • Custom lengths are available on special request. • To order with a union add a “U” to the part number. (i.e. FC-14 becomes FCU-14) Catalog Number APPLICATIONS For use in hazardous areas where movement or vibration requires a bend is required in a conduit system. SPECIFICATIONS NEMA7 Flex Couplings are UL listed for use in the following hazardous areas: ½”, ¾” • Class 1 Groups A, B, C, D • Class II Groups E, F, G 1”, 1-1/2”, 2” • Class 1 Groups C, D • Class II Groups E, F, G 1-1/4” • Class I Group D • Class II Groups E, F, G DIMENSIONS B FLEXIBLE LENGTH 19 A Conduit Size Flexible Length Dim. A Dim. B Catalog Number Conduit Size Flexible Length Dim. A Dim. B FC-14 1/2" 4" 1.54 1.44 FC-324 1" 24" 2 2.31 FC-16 1/2" 6" 1.54 1.44 FC-327 1" 27" 2 2.31 FC-18 1/2" 8" 1.54 1.44 FC-330 1" 30" 2 2.31 FC-110 1/2" 10" 1.54 1.44 FC-333 1" 33" 2 2.31 FC-112 1/2" 12" 1.54 1.44 FC-336 1" 36" 2 2.31 FC-115 1/2" 15" 1.54 1.44 FC-412 1-1/4" 12" 2.12 2.74 FC-118 1/2" 18" 1.54 1.44 FC-415 1-1/4" 15" 2.12 2.74 FC-121 1/2" 21" 1.54 1.44 FC-418 1-1/4" 18" 2.12 2.74 1-1/4" 21" 2.12 2.74 FC-124 1/2" 24" 1.54 1.44 FC-421 FC-127 1/2" 27" 1.54 1.44 FC-424 1-1/4" 24" 2.12 2.74 FC-130 1/2" 30" 1.54 1.44 FC-427 1-1/4" 27" 2.12 2.74 FC-133 1/2" 33" 1.54 1.44 FC-430 1-1/4" 30" 2.12 2.74 FC-136 1/2" 36" 1.54 1.44 FC-433 1-1/4" 33" 2.12 2.74 1-1/4" 36" 2.12 2.74 FC-24 3/4" 4" 1.6 1.87 FC-436 FC-26 3/4" 6" 1.6 1.87 FC-512 1-1/2" 12" 2.37 3.61 FC-28 3/4" 8" 1.6 1.87 FC-515 1-1/2" 15" 2.37 3.61 1-1/2" 18" 2.37 3.61 FC-210 3/4" 10" 1.6 1.87 FC-518 FC-212 3/4" 12" 1.6 1.87 FC-521 1-1/2" 21" 2.37 3.61 FC-215 3/4" 15" 1.6 1.87 FC-524 1-1/2" 24" 2.37 3.61 FC-218 3/4" 18" 1.6 1.87 FC-527 1-1/2" 27" 2.37 3.61 FC-221 3/4" 21" 1.6 1.87 FC-530 1-1/2" 30" 2.37 3.61 FC-224 3/4" 24" 1.6 1.87 FC-533 1-1/2" 33" 2.37 3.61 FC-227 3/4" 27" 1.6 1.87 FC-536 1-1/2" 36" 2.37 3.61 FC-230 3/4" 30" 1.6 1.87 FC-612 2" 12" 2.41 4.33 1.87 FC-615 2" 15" 2.41 4.33 FC-233 3/4" 33" 1.6 FC-236 3/4" 36" 1.6 1.87 FC-618 2" 18" 2.41 4.33 FC-36 1" 6" 2 2.31 FC-621 2" 21" 2.41 4.33 FC-38 1" 8" 2 2.31 FC-624 2" 24" 2.41 4.33 FC-310 1" 10" 2 2.31 FC-627 2" 27" 2.41 4.33 FC-312 1" 12" 2 2.31 FC-630 2" 30" 2.41 4.33 FC-315 1" 15" 2 2.31 FC-633 2" 33" 2.41 4.33 FC-318 1" 18" 2 2.31 FC-636 2" 36" 2.41 4.33 FC-321 1" 21" 2 2.31 NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 EXPLOSION PROOF FITTINGS EXPLOSION PROOF UNIONS Application For use in hazardous locations Thread NPT Female Material Steel Area Class I, Group A, B, C, D · Class II, Group E, F, G B A Catalog Number Thread Size Dim. A Dim. B UNF-50 1/2” 1.78 1.53 UNF-75 3/4” 1.80 1.78 UNF-100 1” 2.03 2.01 Catalog Number Thread Size Dim. A Dim. B EYA-50 1/2” 3.75 1.68 EYA-75 3/4” 3.75 1.90 EYA-100 1” 4.38 2.25 EXPLOSION PROOF SEAL FITTINGS Application from one portion of a conduit system to another. The seal must be placed in each conduit within 3” of the device that may produce arcs or sparks. Thread NPT Female Material Malleable Iron Area Class I, Group A, B, C, D · Class II, Group E, F, G Features Used for sealing vertical or horizontal conduit runs. Requirements Sealing Compound: 1/2” = 1 oz. · 3/4” = 2 oz. · 1” = 3 oz. Note Seal fittings are approved for hazardous location only if fiber and sealing compound are used to make the seal. B A SEALING COMPOUND Catalog Description Std. Pkg Availability Number Application a polyethylene bag within the outer container. It is not XSC 8 8 oz. Tub 1 Stock Catalog Number Description Std. Pkg Availability XAF 64 1 LB 1 Stock XAF 64-1 1 OZ 1 Stock water to the “water line” and pour in the powder. PACKING FIBER • NON-ASBESTOS Application end and around the electrical conductors prior to pouring compound. NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 20 CUSTOM CONTROL PANELS OUR CAPABILITIES TEAMWORK Our approach to customization is simple; we believe that the best results are achieved through a teamwork strategy tailoring our services to meet our customers’ requirements. We have an established network of key vendors who work with us to develop competitive solutions for our control products, and we couple that network with forty years of experience building electrical assemblies. By working together, we enable you to concentrate your resources toward an end product, helping you to COMMITMENT We’re committed to providing quality electrical products that meet the highest NEMA & IEC standards. Our management system adheres to ISO 9001:2008 and our panel shop is certified to build both UL 508A industrial control panels and NNNY/NRBX panels for hazardous locations. EXPERIENCE For over 40 years we’ve specialized in providing value added products and services on electrical equipment for the most demanding of applications and environments. From purge systems and PLC or GUI panels, to electrical control systems for industries as diverse as pharmaceutical, petrochemical, food processing and wasterwater; we and meet your delivery requirements. NEMA7.COM • 800.739.9145 • PH: 918.665.6888 • FAX: 918.663.8615 21 PANELBOARDS Factory-Sealed Panelboards Factory-sealed. No External Seals Required. Fully-Wired from Panelboard Enclosure to Terminal Enclosure. External Operating Handles Can Be Padlocked Either in “ON” or “OFF” Position. Spring-Loaded Operator Handles Allow Cover to Close with Handles in Any Position. Copper Bus is Standard. Isolated Neutral and Ground Bar Provided Available with GFI or EPD Breaker Type 4/IP66 Gasking Provided for Water & Dust Tight Seal. Breather & Drain Provided for Each Enclosure Removable Gland Plates for Field Installation of Conduit Entries Utilizing electrical components from Cutler Hammer, the Adalet factory-sealed panelboards are pre-wired and factory sealed panelboards are pre-wired an factory sealed from the circuit breakers inside the flameproof enclosure to the main distribution blocks and branch terminals housed in an IP66 rated, Type 4x stainless steel increased safety terminal enclosure. The factory seal between the breaker enclosure and terminal enclosure eliminates the need for external sealing. All Adalet factory-sealed panelboards are equipped with padlockable external operating handles, copper bus, isolated neutral and ground bar, GFI or EPD breakers and terminal blocks. Gasket covers provide IP66 and NEMA 4/4X rated protection for a water tight seal and stainless steel cover bolts, removable hinges and breather/drain are included as standard features. NEMA7.COM • 800.739.9145 • PH:918.665.6888 • FAX: 918.663.8615 22 Switchracks Turnkey Switchrack Assemblies for Industrial and Hazardous Locations Features: -Wide Variety of explosion proff motor control assemblies and panelboards. -Rugged frame and canopy options provide heavy duty protection & construction. -Single or double-sided assemblies available in single or double rows. -Pre-drilled bus boxes provide ease of changes or additional components. -Standard drawings of complete switrack design provides detail on all enclosures, frame, canopy and wiring. Hazardous Location Certifications: -Class I, Division I, Groups BCD -Class II, Division I, Groups EFG -Class III -NEMA 4X, 7BCD, 9EFG 23 NEMA7.COM • 800.739.9145 • PH:918.665.6888 • FAX: 918.663.8615 quality electrical products that meet the highest NEMA & IEC standards. Over the past 40 years we’ve established a reputation of providing a high quality end product and a delivery time that is the best in the industry. Our on-site machine shop is equipped to handle a wide variety of value-added services for our products. 24 ELECTRICAL CONTROL PANELS & EQUIPMENT FOR ALL TYPES OF ENVIRONMENTS 4237 S. 74TH E. AVENUE · TULSA OK 74145 WWW.NEMA7.COM PH: 918.665.6888 · FAX: 918.663.8615