Enclosed Control Freedom XT and IT. IEC NEMA ECN 22 2 1 A A F ECR 05 D 1 A A A 3 H = Freedom HVAC N = Freedom T = IT. 2 1 1 See Freedom HVAC Starters Catalog Numbering System to the right. 2 For IT. NEMA Starters – Modification Codes See Chart 9 NEMA Size A = 00 5 = 5 0 =0 6 =6 1 =1 7 =7 2 =2 8 =8 3 =3 9 =9 4 =4 Cover Control (Starters Only) See Charts 3 & 4 add an 11th character for the corresponding overload selection. Class Starters, add an 11th character for the corresponding overload selection. A B C D E F G H J Disconnect Fuse Clip Ratings = None K = 400 A/250 V (R) = 30 A/250 V (R) L = 400 A/600 V (R) = 30 A/600 V (R) M = 600 A/250 V (R) = 60 A/250 V (R) N = 600 A/600 V (R) = 60 A/600 V (R) P = 800 A/600 V (L) = 100 A/250 V (R) Q = 1200 A/600 V (L) = 100 A/600 V (R) R = 1600 A/600 V (L) = 200 A/250 V (R) S = 2000 A/600 V (L) = 200 A/600 V (R) T = By Description A B C D E F HMCP/E or Breaker Ratings = None G = 100 A N = 1000 A =3A H = 150 A P = 1200 A =7A J = 250 A Q = 2000 A = 15 A K = 400 A R = 3000 A = 30 A L = 600 A T = By Description = 50 A M = 800 A 3 For non-combination contactors and starters, include the letter (A) as the 10th character. Enclosure Type 1 = Type 1 – General Purpose 2 = Type 3R – Rainproof 3 = Type 4 – Watertight (Painted Steel) 4 = Type 4X – Watertight (Stainless Steel) 5 = Type 4X – Corrosion (Non-Metallic) 6 = Type 7/9 – Bolted Hazardous Location 7 = Type 7/9 – Threaded Hazardous Location 8 = Type 12 – Dust-Tight 9 = Type 4X – Stainless Steel (316-Grade) A = Type 3R – Rainproof (304-Grade Stainless Steel) NEMA Size Starter 01 = Contactors 02 = Reversing Contactors 05 = FVNR Starter, Non-Combination 06 = Reversing, Non-Combination 07 = FVNR Non-Combination, with CPT 08 = Single-Phase FVNR (Freedom Only) 16 = Combination with Disconnect Switch 17 = Reversing, Combination with Disconnect Switch 18 = Combination with Disconnect Switch, with CPT 22 = Combination with HMCP/E 23 = Reversing, Combination with HMCP/E 24 = Combination with HMCP with CPT 33 = Multispeed 2S2W Non-Combination 34 = Multispeed 2S1W CT or VT Non-Combination 35 = Multispeed 2S1W CH Non-Combination 36 = Multispeed with Disconnect Switch, 2S2W 37 = Multispeed with Disconnect Switch, 2S1W CT or VT 38 = Multispeed with Disconnect Switch, 2S1W CH 39 = Multispeed with HMCP, 2S2W 40 = Multispeed with HMCP, 2S1W CT or VT 41 = Multispeed with HMCP, 2S1W CH 42 = Autotransformer, Non-Combination 43 = Autotransformer, with Disconnect Switch 44 = Autotransformer, with HMCP 45 = Part-Winding, Non-Combination 46 = Part-Winding, with Disconnect Switch 47 = Part-Winding, with Thermal Magnetic Circuit Breakers 48 = Y-D, Open Transition, Non-Combination 49 = Y-D, Open Transition, with Disconnect Switch 50 = Y-D, Open Transition, with Thermal Magnetic Circuit Breakers 51 = Y-D, Closed Transition, Non-Combination 52 = Y-D, Closed Transition, with Disconnect Switch 53 = Y-D, Closed Transition, with Thermal Magnetic Circuit Breakers 62 = Autotransformer Pump Panel, Disconnect Switch 63 = Autotransformer Pump Panel, HMCP 64 = Part-Winding Pump Panel, Disconnect 65 = Part-Winding Pump Panel, HMCP 68 = Duplex, Non-Combination 69 = Duplex, with Disconnect Switch 70 = Duplex, with HMCP Horsepower Rating (Volts) 60 Hz 1-Phase 3-Phase 115 230 200 230 00 0 1 2 9 18 27 45 .33 1 2 3 3 4 5 90 135 270 7.5 — — 1 1.5 2 3 3 7.5 7.5 10 15 — — Modification Codes (Including Fixed Heaters for Classes 9, 10 & 11) See Chart 9 IEC Design X = XT 4 R = IT. 4 4 For IT. and XT IEC Coil Voltage and/or Control Transformer See Charts 1 & 2 Ampere Rating NEMA Design 25 40 75 1.5 3 7.5 15 30 50 100 460 575 2 5 10 25 2 5 10 25 50 50 100 100 200 200 Example: ECN1632ABG Freedom combination with disconnect switch Size 3, NEMA Type 3R enclosure, without CPT, magnet coil of 120 V Start/Stop pushbutton with 100 A/600 V fuse. Class 01 = Contactors 02 = Reversing Contactors 05 = FVNR Starter, Non-Combination, Fixed Heater OLR (XT Compact Version) 06 = Reversing Starter, Fixed Heater OLR (IT. Only) Heater OLR 09 = FVNR Starter, Non-Combination, Fixed Heater OLR (XT Only) 10 = Reversing Starter, Non-Combination, Fixed Heater OLR (XT Only) 11 = FVNR Starter, Non-Combination, Fixed Heater OLR, with CPT (XT Only) 16 = Fusible Switch, Fixed Heater OLR, FVNR (IT. Only) 17 = Fusible Switch, Fixed Heater OLR, FVR (IT. Only) 19 = Fusible Switch, Fixed Heater OLR FVNR (XT Only) 20 = Fusible Switch, Fixed Heater OLR FVR (XT Only) 22 = HMCPE, Fixed Heater OLR, FVNR (IT. Only) 23 = HMCPE, Fixed Heater OLR, FVR (IT. Only) 25 = HMCPE, Fixed Heater OLR FVNR 26 = HMCPE, Fixed Heater OLR FVR 76 = Combination Motor Controller (XT Only) 77 = Reversing Combination Motor Controller (XT Only) Disconnect Fuse Clip Ratings A = None B = 30 A/250 V (R) C = 30 A/600 V (R) D = 60 A/250 V (R) E = 60 A/600 V (R) G = 100 A (J) HMCP/E or Breaker Ratings A = None B =3A C =7A D = 15 A E = 30 A W = 70 A G = 100 A H = 150 A J = 250 A Cover Control (Starters Only) See Charts 3 & 4 Enclosed Control Lighting Controllers ECL 12 D 1 A 3 E Design L = Lighting – CN35 and A202 C = Lighting – C30CN 5 5 C30CN = 30 amperes only. Class 03 = Contactors – Electrically Held CN35/C30CN 04 = Contactors – Mechanically Held C30CN, Magnetic A202 12 = Combination, Fusible – Electrically Held 13 = Combination, Fusible – Mechanically/ Magnetically Held 14 = Combination, Thermal Magnetic Circuit Breakers – Electrically Held 15 = Combination, Thermal Magnetic Circuit Breakers – Mechanically/ Magnetically Held Ampere Rating Coil Voltage and/or Control Transformer See Charts 1 & 2 Enclosure Type 1 = Type 1 – General Purpose 2 = Type 3R – Rainproof 3 = Type 4 – Watertight (Painted Steel) 4 = Type 4X – Watertight (Stainless Steel) 5 = Type 4X – Corrosion (Non-Metallic) 8 = Type 12 – Dust-Tight 9 = Type 4X – Stainless Steel (316-Grade) Ampere Rating (UL 600 V) IT. IEC XT IEC A =6A B =9A C = 12 A D = 18 A E = 25 A F = 32 A G = 40 A H = 50 A J = 65 A K = 85 A L = 100 A M = 125 A N = 160 A P = 200 A R = 250 A S = 315 A T = 400 A B C D E F G H J K L M N P Q =7A =9A = 12 A = 15 A = 18 A = 25 A = 32 A = 40 A = 50 A = 65 A = 80 A = 95 A = 115 A = 150 A A B C D E = 10 A = 20 A = 30 A = 60 A = 100 A F = 200 A G = 300 A H = 400 A C30CN = 30 Amperes Only Enclosure Type 1 = Type 1 – General Purpose 2 = Type 3R – Rainproof 3 = Type 4 – Watertight (Painted Steel) 4 = Type 4X – Watertight (Stainless Steel) 6 = Type 7/9 – Bolted Hazardous Location 7 = Type 7/9 – Threaded Hazardous Location 8 = Type 12 – Dust-Tight 9 = Type 4X – Stainless Steel (316-Grade) Coil Voltage See Charts 1 & 2 Modification Codes (Including Cover Control) See Chart 9 Disconnect Fuse Clip Ratings A B C D E F G H J K L M N P T = None = 30 A/250 VR = 30 A/600 VR = 60 A/250 VR = 60 A/600 VR = 100 A/250 VR = 100 A/600 VR = 200 A/250 VR = 200 A/600 VR = 400 A/250 VR = 400 A/600 VR = 600 A/250 VR = 600 A/600 VR = 800 A/600 VL = By Description Thermal Magnetic Breaker Ratings A D E F G H J K L M T = None = 20 A = 30 A = 60 A = 100 A = 200 A = 300 A = 400 A = 600 A = 800 A = By Description Total Number of Poles 6 2 = 2 Poles Required 3 = 3 Poles Required 4 = 4 Poles Required 5 = 5 Poles Required 6 = 6 Poles Required 7 = 7 Poles Required 8 = 8 Poles Required 9 = 9 Poles Required A = 10 Poles B = 12 Poles C = 20 Poles Z = Consult Factory Combination Devices – 3-Pole Only Other Poles – Consult Factory 6 For NC poles on ECC product, see Modification Codes. Enclosed Control Soft Starters ECS 92 W 2 Q A H - Freedom HVAC Starters ECH 22 0 1 A H - Chart 1: Magnet Coil Codes (System Voltage) 9 A B C D E G H J = 120/60 110/50 = 240/60 220/50 = 480/60 440/50 = 575/60 550/50 = 208/60 = 550/50 = 277/60 = 208 – 240/60 K L M P Q R S T = 240/50 = 380/50 = 415/50 = 12 Vdc = 24 Vdc = 48 Vdc = 120/125 Vdc = 24/60 U = 24/50 V = 32/50 W = 48/60 X = 104 – 120/60 Y = 48/50 Z = By Description 9 When control power transformer Modification Codes Modification Codes See Chart 9 Design S = Soft Starter Class 90 = S801/S752 Non-Combination 91 = S801/S752 Disconnect Switch 92 = S801/S752 Breaker 93 = S811 Non-Combination 94 = S811 Disconnect Switch 95 = S811 Breaker Ampere Rating S752 J K L M N P R = 0.8 A = 1.9 A = 4.4 A = 9.0 A = 16 A = 27 A = 50 A S801/S811 Q S V W Y Z 1 2 3 4 5 6 7 8 = 37 A = 66 A = 105 A = 135 A = 180 A = 240 A = 304 A = 360 A = 420 A = 500 A = 650 A = 720 A = 850 A = 1000 A Enclosure Type 1 == Type Type 3R 1 – –General Purpose Rainproof 2 = Type 3R – Rainproof 3 = Type 4 – Watertight (Painted Steel) 4 = Type 4X – Watertight (Stainless Steel) 6 = Type 7/9 – Bolted 6 Hazardous Location 7 = Type 7/9 – Threaded Hazardous Location 8 = Type 12 – Dust-Tight 9 = Type 4X – Stainless Steel (316-Grade) Control Power Transformer See Chart 2 Disconnect Fuse Clip Ratings A = None B = 30 A/250 V (R) C = 30 A/600 V (R) D = 60 A/250 V (R) E = 60 A/600 V (R) F = 100 A/250 V (R) G = 100 A/600 V (R) H = 200 A/250 V (R) J = 200 A/600 V (R) K = 400 A/250 V (R) L = 400 A/600 V (R) M = 600 A/250 V (R) N = 600 A/600 V (R) P = 800 A/600 V (L) Q== 1200 A/600 V (L) R == 1600 A/600 V (L) S == 2000 A/600 V (L) T = By Description Modification Codes See Chart 9 Design H = HVAC Control Disconnect See Freedom NEMA Disconnect Fuse Clip Ratings. Note: Fuse ratings for HVAC Starters are Type J. Class 16 = Disconnect Switch 18 = Disconnect Switch with CPT 22 = HMCP/E 24 = HMCP/E with CPT Cover Control A = None H = HOA J = HOA & Red Light NEMA Size 0 = Size 0 1 = Size 1 2 = Size 2 Enclosure Type 1 = Type 1 Magnet Coil/CPT Voltage Without CPT CPT Primary/ Secondary A = 120 V/60 Hz B = 240 V/60 Hz C = 460 V/60 Hz D = 575 V/60 Hz E = 208 V/60 Hz T = 24 V/60 Hz B = 240 V/120 V C = 480 V/120 V D = 575 V/120 V E = 208 V/120 V S = 480 V/24 V T = 600 V/24 V Cover Control A = Use Modification Codes Chart 2: Control Power Transformer Codes (System Voltage) Code B = C = D = E = H = K = L = M= P = Q = R = S = T = U = V = W= X = Y = Z = Primary V 240/480 – 220/440 Wired for 240 V 240/480 – 220/440 Wired for 480 575/60 – 550/50 208/60 277/60 Enclosed Microdrive ECS 80 B 1 B A A Modification Codes See Chart 9 Design S = Solid-State Class 80 = Non-combination 81 = Disconnect Switch Combination 82 = Motor Circuit Protector Combination Frame (hp) B = 1/2 7 F = 5 G = 7-1/2 C=1 H = 10 8 D=2 E =3 Enclosure Type 1 = 1 – General Purpose 2 = 3R – Rainproof 3 = 4 – Painted Steel 4 = 4X – 304-Grade Stainless Steel 8 = 12 – Dust-Tight 9 = 4X – 316-Grade Stainless Steel 7 Frame (hp) only available at 208 – 240 V. 8 Frame (hp) only available at 380 – 575 V. Disconnect Rating Fuse Clips A = None C = 30 A (J) E = 30 A (R) Circuit Breaker Ratings A = 15 A B = 20 A D = 30 A E = 40 A F = 50 A Cover Control See Charts 3 & 4 Voltage B = 208 – 240 V C = 380 – 575 V For IT. NEMA Starters, Add an 11th Digit to Choose Overload Size FLA Range NEMA Size Size 00 0 1 2 3 4 5 A B C D A B C D A B C D — — — — — — — — — — — — — — — — 5.0 – 16 6.3 – 20 8.4 – 27 14 – 45 — — — — — F G — — — H — — — — K — — — — — — — — — — — — 28 – 90 42 – 135 84 – 270 — — — — — — — — — — — — M — — — P — — — S .25 – .8 .59 – 1.9 1.4 – 4.4 2.8 – 9.0 120/60 – 110/50 120/60 – 110/50 120/60 – 110/50 120/60 120/60 380/415 V 220 V 380/50 415/50 120/60 V 208/60 240/480 – 220/440 Wired for 240 V 240/480 – 220/440 Wired for 480 575/60 277/60 380/50 V 415/50 240/480/600 Wired for 480 V 240/480/600 Wired for 480 By Description 110/50 110/50 24 24 24 24 24 24 24 24 120 24 Chart 3: Cover Control — Non-Reversing J A = None B = Start/Stop Pushbuttons C = Start/Stop Pushbuttons, Run (R) Pilot Light D = Start/Stop Pushbuttons, Run (R), Off (G) Pilot Lights E = On/Off Pushbuttons F = On/Off Pushbuttons, Run (R) Pilot Light G = On/Off Pushbuttons, Run (R), Off (G) Pilot Lights H = Hand/Off/Auto Selector Switch J = Hand/Off/Auto Selector Switch, Run (R) Pilot Light K = Hand/Off/Auto Selector Switch, Run (R), Off (G) Pilot Lights L = Start Pushbutton M = On Pushbutton N = Off Pushbutton P = Run-Red Pilot Light Q = Off-Green Pilot Light R = Run (R) - Off (G) Pilot Lights S = Start/Stop Selector Switch T = Start/Stop Selector Switch, Run (R) Pilot Light U = Start/Stop Selector Switch, Run (R), Off (G) Pilot Lights V = On/Off Selector Switch W = On/Off Selector Switch, Run (R) Pilot Light X = On/Off Selector Switch, Run (R), Off (G) Pilot Lights Z = By Description J Starters only — contactor cover control: use Modification Codes. Chart 4: Cover Control — Reversing K Use for Class 06, 10, 17, 20, 23, 26 A = None B = Forward/Reverse/Stop Pushbuttons C = Forward/Reverse/Stop Pushbuttons, 2 Red Pilot Lights D = Forward/Reverse/Stop Pushbuttons, 2 Red, 1 Green Pilot Lights s E = Up/Stop/Down Pushbuttons F = Up/Stop/Down Pushbuttons, 2 Red Pilot Lights H = Forward/Off/Reverse Selector Switch J = Forward/Off/Reverse Selector Switch, 2 Red Pilot Lights s K = Forward/Off/Reverse Selector Switch, 2 Red, 1 Green Pilot Lights P = 2 Red Pilot Lights Q = 1 Green Pilot Light R = 2 Red, 1 Green Pilot Lights V = Open/Off/Close Selector Switch W = Open/Off/Close Selector Switch, 2 Red Pilot Lights s X = Open/Off/Close Selector Switch, 2 Red, 1 Green Pilot Lights Z = By Description K Starters only — contactor cover control: use Modification Codes. B-Frame 45 mm A 6 B 9 .25 – .8 .59 – 1.9 1.4 – 4.4 A B C — — A — — B C — C 2.8 – 9.0 3.8 – 12 5.0 – 16 D C-Frame D-Frame 54 mm 76 mm 10 20 10/20 R50 R53 R51 R54 00 0.1 – 1.3 0.3 – 1.0 1.0 – 2.9 1.6 – 5.0 G101 G102 G103 G104 G81 G82 G83 G84 G141 G142 G143 G144 G121 G122 G123 G124 G221 G222 G223 G224 3.7 – 12 G105 G85 G145 G125 G225 0.1 – 1.3 0.3 – 1.0 1.0 – 2.9 1.6 – 5.0 G101 G102 G103 G104 G81 G82 G83 G84 G141 G142 G143 G144 G121 G122 G123 G124 G221 G222 G223 G224 3.7 – 12 G105 G85 G145 G125 G225 12 – 32 G106 G86 G146 G126 G226 12 – 37 G107 G87 G147 G127 — 14 – 45 G108 G88 G148 G128 G227 3 26 – 85 G109 G89 G149 G129 C D E F G 12 18 25 32 40 H 50 G228 4 57 – 180 G112 G92 G152 G132 — 5 96 – 300 G104 G84 G144 G124 — 6 192 – 600 G104 G84 G144 G124 — 2 E-Frame 105 mm F-Frame 140 mm J K L M N P R S T 65 80 100 125 160 200 250 315 420 Class 20 Chart 6: Overload Size (IT. IEC) A-Frame 27 mm 3-Phase Automatic/ Ground Fault Manual Reset R52 Example: ECT2238CAG-M = Size 3 IT. combination NEMA 12, 28 – 90 ampere overload. FLA Range 3-Phase Manual Reset Overload 10 0&1 For IT. IEC Starters, Add an 11th Digit to Choose Overload Size Full Load Current Adjustment Range (A) Catalog Number Suffix Secondary Note: Use when ordering classes with CPT installed (i.e., ECN 18) and when using Modification Codes CI – CII. HMCP or Breaker Ratings A = None B =3A C =7A D = 15 A E = 30 A F = 50 A G = 100 A H = 150 A J = 250 A K = 400 A L = 600 A M = 800 A N = 1000 A P = 1200 A Q = 2000 A R = 3000 A T = By Description (CI – CII) are used, pick the system (primary) voltage from this chart. See Chart 2. Note: All IT. contactors and starters are furnished with 24 Vdc coil and control power supply. The eighth digit Q denotes separate 24 Vdc control source. Chart 8: Modification Codes — Solid-State Overload for Freedom Starters Chart 5: Overload Size (IT. NEMA) — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — D — D — — — — — — — — E E — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 6.3 – 20 8.4 – 27 10 – 32 — — — G G — — — — — — — — — — — — H — — — — — — — — J J — — — — — — — — — — — — — — — — — — — — — — — A1 = Ammeter, panel type wired to current transformer in line. A2 = Ammeter, panel type, selector switch, and 3 current transformers wired 14 – 45 16 – 50 31 – 100 — — — — — — — — K — — — — — — — — L L — — — — — — — — — — — N N N — — — — — — — — — — — — — — — — — — — — — — P — — — — — R R — — — — — — S — — — — — — — T T A7 A13 A15 A16 A44 A23 A29 B1 B3 42 – 135 63 – 200 84 – 270 131 – 420 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Chart 9: Typical Examples of Common Modification Codes to ammeter. = Ammeters, (single-phase) total of 3. = Auxiliary Contact, 1NO top mounted. = Auxiliary Contact, 1NO – 1NC top mounted. = Auxiliary Contact, 2NO top mounted. = Auxiliary Contact, omitted. = Auxiliary Contact, 2NO – 2NC top mounted. = Auxiliary Contact, 1NO – 1NC side mounted. = Breaker Modifications, 1NO – 1NC Auxiliary Contact on HMCP. = Breaker Modifications, Shunt Trip on circuit breaker, 48 – 127 Vac or Vdc. Chart 7: XTOB Overload Relays FLA Range Example: R50/G87 = Class 20, 12 – 37 ampere overload for A Size 2 starters. C1 = Control Power Transformer, standard size, 120 V/60 Hz secondary. C3 = Control Power Transformer, 100 VA extra capacity, Frame Size B 12 C 32 D 65 F 95 G 150 0.1 – 0.16 0.16 – 0.24 0.24 – 0.4 A B C A B C — — — — — — — — — 0.4 – 0.6 0.6 – 1 1 – 1.6 D D E F E F — — — — — — — — — 1.6 – 2.4 2.4 – 4 6 – Apr G H I G H I — — — — — — — — — 10 – Jun 12 – Sep 16 – Oct J K — J — L J — L — — — — — — 16 – 24 24 – 32 24 – 40 — — — M N — M — O — — — — — — 25 – 35 35 – 50 40 – 57 — — — — — — — — P S T — S T — 50 – 65 50 – 70 70 – 100 95 – 125 — — — — — — — — Q — — — — U V — — U V W 120 V/60 Hz secondary. C4 = Control Power Transformer, 100 VA extra capacity, 24 V/60 Hz secondary. C14 C35 C36 C37 D15 E3 E11 G3 L3 L10 L21 L22 L23 L24 L25 L26 L27 L28 N1 P1 P2 P7 P18 P32 P34 S3 S18 S40 T15 = Control Relay, 4-pole, unwired, A600 rating, 120 V coil. = Control, wired for separate. = Customer supplied material. = Customer supplied drawings. = HOA for each motor (duplex pumps). = Enclosure Modifications, oversize enclosure. = Safety Door Interlock enclosure assembly. = Ground Fault Relay, unwired, installed. = Lightning Arrester installed on panel. = Carton Label — order by description. = 1NC Power Pole. = 2NC Power Pole. = 3NC Power Pole. = 4NC Power Pole. = 5NC Power Pole. = 6NC Power Pole. = 7NC Power Pole. = 8NC Power Pole. = Nameplate — order by description. = Push-to-Test Pilot Light (red RUN) wired to magnet coil. = Push-to-Test Pilot Light (green OFF) wired to magnet coil. = Start/Stop Pushbutton. = Pushbutton with Legend Plate — order by description. = Phase Unbalance Relay. = Phase Monitoring Relay. = Selector Switch HOA. = Selector Switch, HIGH-LOW-OFF-AUTO. = Selector Switch — order by description. = Customer designated terminal points.