Freedom Numbering guide chart - EMSCO, The Motor Control Shop

advertisement
Enclosed Control Freedom XT and IT.
IEC
NEMA
ECN 22 2 1 A A F ECR 05 D 1 A A A 3
H = Freedom HVAC
N = Freedom
T = IT. 2
1
1 See Freedom HVAC Starters
Catalog Numbering System
to the right.
2 For IT. NEMA Starters –
Modification Codes
See Chart 9
NEMA Size
A = 00 5 = 5
0 =0 6 =6
1 =1 7 =7
2 =2 8 =8
3 =3 9 =9
4 =4
Cover Control
(Starters Only)
See Charts 3 & 4
add an 11th character
for the corresponding
overload selection.
Class
Starters, add an 11th
character for the
corresponding overload selection.
A
B
C
D
E
F
G
H
J
Disconnect Fuse Clip Ratings
= None
K = 400 A/250 V (R)
= 30 A/250 V (R)
L = 400 A/600 V (R)
= 30 A/600 V (R)
M = 600 A/250 V (R)
= 60 A/250 V (R)
N = 600 A/600 V (R)
= 60 A/600 V (R)
P = 800 A/600 V (L)
= 100 A/250 V (R)
Q = 1200 A/600 V (L)
= 100 A/600 V (R)
R = 1600 A/600 V (L)
= 200 A/250 V (R)
S = 2000 A/600 V (L)
= 200 A/600 V (R)
T = By Description
A
B
C
D
E
F
HMCP/E or Breaker Ratings
= None
G = 100 A
N = 1000 A
=3A
H = 150 A
P = 1200 A
=7A
J = 250 A
Q = 2000 A
= 15 A
K = 400 A
R = 3000 A
= 30 A
L = 600 A
T = By Description
= 50 A
M = 800 A
3 For non-combination contactors and starters,
include the letter (A) as the 10th character.
Enclosure Type
1 = Type 1 – General Purpose
2 = Type 3R – Rainproof
3 = Type 4 – Watertight (Painted Steel)
4 = Type 4X – Watertight (Stainless Steel)
5 = Type 4X – Corrosion (Non-Metallic)
6 = Type 7/9 – Bolted Hazardous Location
7 = Type 7/9 – Threaded Hazardous Location
8 = Type 12 – Dust-Tight
9 = Type 4X – Stainless Steel (316-Grade)
A = Type 3R – Rainproof (304-Grade
Stainless Steel)
NEMA
Size Starter
01 = Contactors
02 = Reversing Contactors
05 = FVNR Starter, Non-Combination
06 = Reversing, Non-Combination
07 = FVNR Non-Combination, with CPT
08 = Single-Phase FVNR (Freedom Only)
16 = Combination with Disconnect Switch
17 = Reversing, Combination with Disconnect Switch
18 = Combination with
Disconnect Switch, with CPT
22 = Combination with HMCP/E
23 = Reversing, Combination with HMCP/E
24 = Combination with HMCP with CPT
33 = Multispeed 2S2W Non-Combination
34 = Multispeed 2S1W CT or VT Non-Combination
35 = Multispeed 2S1W CH Non-Combination
36 = Multispeed with Disconnect Switch, 2S2W
37 = Multispeed with Disconnect Switch,
2S1W CT or VT
38 = Multispeed with Disconnect Switch, 2S1W CH
39 = Multispeed with HMCP, 2S2W
40 = Multispeed with HMCP, 2S1W CT or VT
41 = Multispeed with HMCP, 2S1W CH
42 = Autotransformer, Non-Combination
43 = Autotransformer, with Disconnect Switch
44 = Autotransformer, with HMCP
45 = Part-Winding, Non-Combination
46 = Part-Winding, with Disconnect Switch
47 = Part-Winding, with Thermal
Magnetic Circuit Breakers
48 = Y-D, Open Transition, Non-Combination
49 = Y-D, Open Transition, with Disconnect Switch
50 = Y-D, Open Transition, with Thermal
Magnetic Circuit Breakers
51 = Y-D, Closed Transition, Non-Combination
52 = Y-D, Closed Transition,
with Disconnect Switch
53 = Y-D, Closed Transition, with
Thermal Magnetic Circuit Breakers
62 = Autotransformer Pump Panel,
Disconnect Switch
63 = Autotransformer Pump Panel, HMCP
64 = Part-Winding Pump Panel, Disconnect
65 = Part-Winding Pump Panel, HMCP
68 = Duplex, Non-Combination
69 = Duplex, with Disconnect Switch
70 = Duplex, with HMCP
Horsepower Rating (Volts) 60 Hz
1-Phase
3-Phase
115 230 200 230
00
0
1
2
9
18
27
45
.33
1
2
3
3
4
5
90
135
270
7.5
—
—
1
1.5
2
3
3
7.5
7.5 10
15
—
—
Modification Codes
(Including Fixed
Heaters for Classes 9,
10 & 11) See Chart 9
IEC Design
X = XT 4
R = IT. 4
4 For IT. and XT IEC
Coil Voltage and/or
Control Transformer
See Charts 1 & 2
Ampere
Rating
NEMA Design
25
40
75
1.5
3
7.5
15
30
50
100
460 575
2
5
10
25
2
5
10
25
50 50
100 100
200 200
Example: ECN1632ABG
Freedom combination with disconnect switch Size 3, NEMA Type 3R enclosure, without CPT, magnet
coil of 120 V Start/Stop pushbutton with 100 A/600 V fuse.
Class
01 = Contactors
02 = Reversing Contactors
05 = FVNR Starter,
Non-Combination,
Fixed Heater OLR (XT
Compact Version)
06 = Reversing Starter,
Fixed Heater OLR
(IT. Only)
Heater OLR
09 = FVNR Starter,
Non-Combination,
Fixed Heater OLR
(XT Only)
10 = Reversing Starter,
Non-Combination,
Fixed Heater OLR
(XT Only)
11 = FVNR Starter,
Non-Combination,
Fixed Heater OLR,
with CPT (XT Only)
16 = Fusible Switch, Fixed
Heater OLR, FVNR
(IT. Only)
17 = Fusible Switch, Fixed
Heater OLR, FVR
(IT. Only)
19 = Fusible Switch,
Fixed Heater OLR FVNR
(XT Only)
20 = Fusible Switch,
Fixed Heater OLR FVR
(XT Only)
22 = HMCPE, Fixed Heater
OLR, FVNR (IT. Only)
23 = HMCPE, Fixed Heater
OLR, FVR (IT. Only)
25 = HMCPE, Fixed Heater
OLR FVNR
26 = HMCPE, Fixed Heater
OLR FVR
76 = Combination Motor
Controller (XT Only)
77 = Reversing Combination
Motor Controller (XT Only)
Disconnect Fuse
Clip Ratings
A = None
B = 30 A/250 V (R)
C = 30 A/600 V (R)
D = 60 A/250 V (R)
E = 60 A/600 V (R)
G = 100 A (J)
HMCP/E or
Breaker Ratings
A = None
B =3A
C =7A
D = 15 A
E = 30 A
W = 70 A
G = 100 A
H = 150 A
J = 250 A
Cover Control
(Starters Only)
See Charts 3 & 4
Enclosed Control
Lighting Controllers
ECL 12 D 1 A 3 E Design
L = Lighting – CN35
and A202
C = Lighting – C30CN 5
5 C30CN =
30 amperes only.
Class
03 = Contactors – Electrically
Held CN35/C30CN
04 = Contactors –
Mechanically Held
C30CN, Magnetic A202
12 = Combination, Fusible –
Electrically Held
13 = Combination, Fusible –
Mechanically/
Magnetically Held
14 = Combination,
Thermal Magnetic
Circuit Breakers –
Electrically Held
15 = Combination,
Thermal Magnetic
Circuit Breakers –
Mechanically/
Magnetically Held
Ampere Rating
Coil Voltage and/or
Control Transformer
See Charts 1 & 2
Enclosure Type
1 = Type 1 – General Purpose
2 = Type 3R – Rainproof
3 = Type 4 – Watertight
(Painted Steel)
4 = Type 4X – Watertight
(Stainless Steel)
5 = Type 4X – Corrosion
(Non-Metallic)
8 = Type 12 – Dust-Tight
9 = Type 4X – Stainless Steel
(316-Grade)
Ampere Rating (UL 600 V)
IT. IEC
XT IEC
A =6A
B =9A
C = 12 A
D = 18 A
E = 25 A
F = 32 A
G = 40 A
H = 50 A
J = 65 A
K = 85 A
L = 100 A
M = 125 A
N = 160 A
P = 200 A
R = 250 A
S = 315 A
T = 400 A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
=7A
=9A
= 12 A
= 15 A
= 18 A
= 25 A
= 32 A
= 40 A
= 50 A
= 65 A
= 80 A
= 95 A
= 115 A
= 150 A
A
B
C
D
E
= 10 A
= 20 A
= 30 A
= 60 A
= 100 A
F = 200 A
G = 300 A
H = 400 A
C30CN = 30 Amperes Only
Enclosure Type
1 = Type 1 – General Purpose
2 = Type 3R – Rainproof
3 = Type 4 – Watertight
(Painted Steel)
4 = Type 4X – Watertight
(Stainless Steel)
6 = Type 7/9 – Bolted
Hazardous Location
7 = Type 7/9 – Threaded
Hazardous Location
8 = Type 12 – Dust-Tight
9 = Type 4X – Stainless Steel
(316-Grade)
Coil Voltage
See Charts 1 & 2
Modification Codes
(Including Cover
Control) See Chart 9
Disconnect
Fuse Clip Ratings
A
B
C
D
E
F
G
H
J
K
L
M
N
P
T
= None
= 30 A/250 VR
= 30 A/600 VR
= 60 A/250 VR
= 60 A/600 VR
= 100 A/250 VR
= 100 A/600 VR
= 200 A/250 VR
= 200 A/600 VR
= 400 A/250 VR
= 400 A/600 VR
= 600 A/250 VR
= 600 A/600 VR
= 800 A/600 VL
= By Description
Thermal Magnetic
Breaker Ratings
A
D
E
F
G
H
J
K
L
M
T
= None
= 20 A
= 30 A
= 60 A
= 100 A
= 200 A
= 300 A
= 400 A
= 600 A
= 800 A
= By Description
Total Number of Poles 6
2 = 2 Poles Required
3 = 3 Poles Required
4 = 4 Poles Required
5 = 5 Poles Required
6 = 6 Poles Required
7 = 7 Poles Required
8 = 8 Poles Required
9 = 9 Poles Required
A = 10 Poles
B = 12 Poles
C = 20 Poles
Z = Consult Factory
Combination Devices –
3-Pole Only
Other Poles –
Consult Factory
6 For NC poles on
ECC product, see
Modification Codes.
Enclosed Control Soft Starters
ECS 92 W 2 Q A H -
Freedom HVAC Starters
ECH 22 0 1 A H
-
Chart 1: Magnet Coil Codes (System Voltage) 9
A
B
C
D
E
G
H
J
= 120/60 110/50
= 240/60 220/50
= 480/60 440/50
= 575/60 550/50
= 208/60
= 550/50
= 277/60
= 208 – 240/60
K
L
M
P
Q
R
S
T
= 240/50
= 380/50
= 415/50
= 12 Vdc
= 24 Vdc
= 48 Vdc
= 120/125 Vdc
= 24/60
U = 24/50
V = 32/50
W = 48/60
X = 104 – 120/60
Y = 48/50
Z = By Description
9 When control power transformer Modification Codes
Modification
Codes
See Chart 9
Design
S = Soft Starter
Class
90 = S801/S752 Non-Combination
91 = S801/S752 Disconnect
Switch
92 = S801/S752 Breaker
93 = S811 Non-Combination
94 = S811 Disconnect Switch
95 = S811 Breaker
Ampere Rating
S752
J
K
L
M
N
P
R
= 0.8 A
= 1.9 A
= 4.4 A
= 9.0 A
= 16 A
= 27 A
= 50 A
S801/S811
Q
S
V
W
Y
Z
1
2
3
4
5
6
7
8
= 37 A
= 66 A
= 105 A
= 135 A
= 180 A
= 240 A
= 304 A
= 360 A
= 420 A
= 500 A
= 650 A
= 720 A
= 850 A
= 1000 A
Enclosure Type
1 == Type
Type 3R
1 – –General
Purpose
Rainproof
2 = Type 3R – Rainproof
3 = Type 4 – Watertight
(Painted Steel)
4 = Type 4X – Watertight
(Stainless Steel)
6 = Type 7/9 – Bolted
6 Hazardous Location
7 = Type 7/9 – Threaded
Hazardous Location
8 = Type 12 – Dust-Tight
9 = Type 4X – Stainless Steel
(316-Grade)
Control Power
Transformer
See Chart 2
Disconnect
Fuse Clip Ratings
A = None
B = 30 A/250 V (R)
C = 30 A/600 V (R)
D = 60 A/250 V (R)
E = 60 A/600 V (R)
F = 100 A/250 V (R)
G = 100 A/600 V (R)
H = 200 A/250 V (R)
J = 200 A/600 V (R)
K = 400 A/250 V (R)
L = 400 A/600 V (R)
M = 600 A/250 V (R)
N = 600 A/600 V (R)
P = 800 A/600 V (L)
Q== 1200 A/600 V (L)
R == 1600 A/600 V (L)
S == 2000 A/600 V (L)
T = By Description
Modification Codes
See Chart 9
Design
H = HVAC Control
Disconnect
See Freedom NEMA
Disconnect Fuse Clip
Ratings. Note: Fuse ratings
for HVAC Starters are Type J.
Class
16 = Disconnect Switch
18 = Disconnect Switch
with CPT
22 = HMCP/E
24 = HMCP/E with CPT
Cover Control
A = None
H = HOA
J = HOA & Red Light
NEMA Size
0 = Size 0
1 = Size 1
2 = Size 2
Enclosure Type
1 = Type 1
Magnet Coil/CPT Voltage
Without
CPT
CPT Primary/
Secondary
A = 120 V/60 Hz
B = 240 V/60 Hz
C = 460 V/60 Hz
D = 575 V/60 Hz
E = 208 V/60 Hz
T = 24 V/60 Hz
B = 240 V/120 V
C = 480 V/120 V
D = 575 V/120 V
E = 208 V/120 V
S = 480 V/24 V
T = 600 V/24 V
Cover Control
A = Use Modification Codes
Chart 2: Control Power Transformer Codes
(System Voltage)
Code
B =
C =
D =
E =
H =
K =
L =
M=
P =
Q =
R =
S =
T =
U =
V =
W=
X =
Y =
Z =
Primary
V
240/480 – 220/440 Wired for 240 V
240/480 – 220/440 Wired for 480
575/60 – 550/50
208/60
277/60
Enclosed Microdrive
ECS 80 B 1 B A A Modification
Codes
See Chart 9
Design
S = Solid-State
Class
80 = Non-combination
81 = Disconnect
Switch Combination
82 = Motor Circuit
Protector Combination
Frame (hp)
B = 1/2 7 F = 5
G = 7-1/2
C=1
H = 10 8
D=2
E =3
Enclosure Type
1 = 1 – General Purpose
2 = 3R – Rainproof
3 = 4 – Painted Steel
4 = 4X – 304-Grade Stainless Steel
8 = 12 – Dust-Tight
9 = 4X – 316-Grade Stainless Steel
7 Frame (hp) only available at 208 – 240 V.
8 Frame (hp) only available at 380 – 575 V.
Disconnect Rating
Fuse Clips
A = None
C = 30 A (J)
E = 30 A (R)
Circuit Breaker
Ratings
A = 15 A
B = 20 A
D = 30 A
E = 40 A
F = 50 A
Cover Control
See Charts 3 & 4
Voltage
B = 208 – 240 V
C = 380 – 575 V
For IT. NEMA Starters, Add an 11th Digit to Choose Overload Size
FLA
Range
NEMA
Size
Size
00
0
1
2
3
4
5
A
B
C
D
A
B
C
D
A
B
C
D
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5.0 – 16
6.3 – 20
8.4 – 27
14 – 45
—
—
—
—
—
F
G
—
—
—
H
—
—
—
—
K
—
—
—
—
—
—
—
—
—
—
—
—
28 – 90
42 – 135
84 – 270
—
—
—
—
—
—
—
—
—
—
—
—
M
—
—
—
P
—
—
—
S
.25 – .8
.59 – 1.9
1.4 – 4.4
2.8 – 9.0
120/60 – 110/50
120/60 – 110/50
120/60 – 110/50
120/60
120/60
380/415 V
220 V
380/50
415/50
120/60
V
208/60
240/480 – 220/440 Wired for 240 V
240/480 – 220/440 Wired for 480
575/60
277/60
380/50
V
415/50
240/480/600 Wired for 480 V
240/480/600 Wired for 480
By Description
110/50
110/50
24
24
24
24
24
24
24
24
120
24
Chart 3: Cover Control — Non-Reversing J
A = None
B = Start/Stop Pushbuttons
C = Start/Stop Pushbuttons, Run (R) Pilot Light
D = Start/Stop Pushbuttons, Run (R), Off (G) Pilot Lights
E = On/Off Pushbuttons
F = On/Off Pushbuttons, Run (R) Pilot Light
G = On/Off Pushbuttons, Run (R), Off (G) Pilot Lights
H = Hand/Off/Auto Selector Switch
J = Hand/Off/Auto Selector Switch, Run (R) Pilot Light
K = Hand/Off/Auto Selector Switch, Run (R), Off (G) Pilot Lights
L = Start Pushbutton
M = On Pushbutton
N = Off Pushbutton
P = Run-Red Pilot Light
Q = Off-Green Pilot Light
R = Run (R) - Off (G) Pilot Lights
S = Start/Stop Selector Switch
T = Start/Stop Selector Switch, Run (R) Pilot Light
U = Start/Stop Selector Switch, Run (R), Off (G) Pilot Lights
V = On/Off Selector Switch
W = On/Off Selector Switch, Run (R) Pilot Light
X = On/Off Selector Switch, Run (R), Off (G) Pilot Lights
Z = By Description
J Starters only — contactor cover control: use Modification Codes.
Chart 4: Cover Control — Reversing K
Use for Class 06, 10, 17, 20, 23, 26
A = None
B = Forward/Reverse/Stop Pushbuttons
C = Forward/Reverse/Stop Pushbuttons, 2 Red Pilot Lights
D = Forward/Reverse/Stop Pushbuttons, 2 Red, 1 Green Pilot Lights
s
E = Up/Stop/Down Pushbuttons
F = Up/Stop/Down Pushbuttons, 2 Red Pilot Lights
H = Forward/Off/Reverse Selector Switch
J = Forward/Off/Reverse Selector Switch, 2 Red Pilot Lights
s
K = Forward/Off/Reverse Selector Switch, 2 Red, 1 Green Pilot Lights
P = 2 Red Pilot Lights
Q = 1 Green Pilot Light
R = 2 Red, 1 Green Pilot Lights
V = Open/Off/Close Selector Switch
W = Open/Off/Close Selector Switch, 2 Red Pilot Lights
s
X = Open/Off/Close Selector Switch, 2 Red, 1 Green Pilot Lights
Z = By Description
K Starters only — contactor cover control: use Modification Codes.
B-Frame
45 mm
A
6
B
9
.25 – .8
.59 – 1.9
1.4 – 4.4
A
B
C
— — A
— — B
C — C
2.8 – 9.0
3.8 – 12
5.0 – 16
D
C-Frame D-Frame
54 mm 76 mm
10
20
10/20
R50
R53
R51
R54
00
0.1 – 1.3
0.3 – 1.0
1.0 – 2.9
1.6 – 5.0
G101
G102
G103
G104
G81
G82
G83
G84
G141
G142
G143
G144
G121
G122
G123
G124
G221
G222
G223
G224
3.7 – 12
G105
G85
G145
G125
G225
0.1 – 1.3
0.3 – 1.0
1.0 – 2.9
1.6 – 5.0
G101
G102
G103
G104
G81
G82
G83
G84
G141
G142
G143
G144
G121
G122
G123
G124
G221
G222
G223
G224
3.7 – 12
G105
G85
G145
G125
G225
12 – 32
G106
G86
G146
G126
G226
12 – 37
G107
G87
G147
G127
—
14 – 45
G108
G88
G148
G128
G227
3
26 – 85
G109
G89
G149
G129
C D E F G
12 18 25 32 40
H
50
G228
4
57 – 180
G112
G92
G152
G132
—
5
96 – 300
G104
G84
G144
G124
—
6
192 – 600
G104
G84
G144
G124
—
2
E-Frame
105 mm
F-Frame
140 mm
J K L
M N P
R
S
T
65 80 100 125 160 200 250 315 420
Class
20
Chart 6: Overload Size (IT. IEC)
A-Frame
27 mm
3-Phase Automatic/ Ground
Fault
Manual Reset
R52
Example: ECT2238CAG-M = Size 3 IT. combination NEMA 12, 28 – 90 ampere overload.
FLA
Range
3-Phase Manual
Reset Overload
10
0&1
For IT. IEC Starters, Add an 11th Digit to Choose Overload Size
Full Load
Current
Adjustment
Range (A)
Catalog Number Suffix
Secondary
Note: Use when ordering classes with CPT installed (i.e., ECN 18)
and when using Modification Codes CI – CII.
HMCP or
Breaker Ratings
A = None
B =3A
C =7A
D = 15 A
E = 30 A
F = 50 A
G = 100 A
H = 150 A
J = 250 A
K = 400 A
L = 600 A
M = 800 A
N = 1000 A
P = 1200 A
Q = 2000 A
R = 3000 A
T = By Description
(CI – CII) are used, pick the system (primary) voltage from
this chart. See Chart 2.
Note: All IT. contactors and starters are furnished with
24 Vdc coil and control power supply. The eighth digit
Q denotes separate 24 Vdc control source.
Chart 8: Modification Codes —
Solid-State Overload for Freedom Starters
Chart 5: Overload Size (IT. NEMA)
— — — — — — —
— — — — — — —
— — — — — — —
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
D — D — — — — — — —
— E E — — — — — — — —
— — — — — — — — — —
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
6.3 – 20
8.4 – 27
10 – 32
— — — G G — — — — — —
— — — — — — H — — — —
— — — — J J — — — — —
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
A1 = Ammeter, panel type wired to current transformer in line.
A2 = Ammeter, panel type, selector switch, and 3 current transformers wired
14 – 45
16 – 50
31 – 100
— — — — — — — — K — —
— — — — — — L
L — — —
— — — — — — — — N N N
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
P
—
—
—
—
—
R
R
—
—
—
—
—
—
S
—
—
—
—
—
—
—
T
T
A7
A13
A15
A16
A44
A23
A29
B1
B3
42 – 135
63 – 200
84 – 270
131 – 420
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Chart 9: Typical Examples of Common Modification Codes
to ammeter.
= Ammeters, (single-phase) total of 3.
= Auxiliary Contact, 1NO top mounted.
= Auxiliary Contact, 1NO – 1NC top mounted.
= Auxiliary Contact, 2NO top mounted.
= Auxiliary Contact, omitted.
= Auxiliary Contact, 2NO – 2NC top mounted.
= Auxiliary Contact, 1NO – 1NC side mounted.
= Breaker Modifications, 1NO – 1NC Auxiliary Contact on HMCP.
= Breaker Modifications, Shunt Trip on circuit breaker,
48 – 127 Vac or Vdc.
Chart 7: XTOB Overload Relays
FLA
Range
Example: R50/G87 = Class 20, 12 – 37 ampere overload for A Size 2 starters.
C1 = Control Power Transformer, standard size, 120 V/60 Hz secondary.
C3 = Control Power Transformer, 100 VA extra capacity,
Frame Size
B
12
C
32
D
65
F
95
G
150
0.1 – 0.16
0.16 – 0.24
0.24 – 0.4
A
B
C
A
B
C
—
—
—
—
—
—
—
—
—
0.4 – 0.6
0.6 – 1
1 – 1.6
D
D
E
F
E
F
—
—
—
—
—
—
—
—
—
1.6 – 2.4
2.4 – 4
6 – Apr
G
H
I
G
H
I
—
—
—
—
—
—
—
—
—
10 – Jun
12 – Sep
16 – Oct
J
K
—
J
—
L
J
—
L
—
—
—
—
—
—
16 – 24
24 – 32
24 – 40
—
—
—
M
N
—
M
—
O
—
—
—
—
—
—
25 – 35
35 – 50
40 – 57
—
—
—
—
—
—
—
—
P
S
T
—
S
T
—
50 – 65
50 – 70
70 – 100
95 – 125
—
—
—
—
—
—
—
—
Q
—
—
—
—
U
V
—
—
U
V
W
120 V/60 Hz secondary.
C4 = Control Power Transformer, 100 VA extra capacity,
24 V/60 Hz secondary.
C14
C35
C36
C37
D15
E3
E11
G3
L3
L10
L21
L22
L23
L24
L25
L26
L27
L28
N1
P1
P2
P7
P18
P32
P34
S3
S18
S40
T15
= Control Relay, 4-pole, unwired, A600 rating, 120 V coil.
= Control, wired for separate.
= Customer supplied material.
= Customer supplied drawings.
= HOA for each motor (duplex pumps).
= Enclosure Modifications, oversize enclosure.
= Safety Door Interlock enclosure assembly.
= Ground Fault Relay, unwired, installed.
= Lightning Arrester installed on panel.
= Carton Label — order by description.
= 1NC Power Pole.
= 2NC Power Pole.
= 3NC Power Pole.
= 4NC Power Pole.
= 5NC Power Pole.
= 6NC Power Pole.
= 7NC Power Pole.
= 8NC Power Pole.
= Nameplate — order by description.
= Push-to-Test Pilot Light (red RUN) wired to magnet coil.
= Push-to-Test Pilot Light (green OFF) wired to magnet coil.
= Start/Stop Pushbutton.
= Pushbutton with Legend Plate — order by description.
= Phase Unbalance Relay.
= Phase Monitoring Relay.
= Selector Switch HOA.
= Selector Switch, HIGH-LOW-OFF-AUTO.
= Selector Switch — order by description.
= Customer designated terminal points.