Submitting Agency: Description: 2VT8 2 32 ADP MVOLT GEB10IS PWS1836 LP841 Project: Notes: Cascade Periodontics GRID MOUNT; LAMPS AND FLEX INCLUDED Type: A Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — The VT™ troffer combines the aesthetics and high performance levels of volumetric lighting, with the best value for offices, schools, retail locations and hospitals. Available in one-, two- or three-lamp configurations, with T5 or T8 lamps, this series provides the ultimate in design flexibility. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. Type CONSTRUCTION — Rugged, one-piece cold-rolled steel coated polyester, painted after fabrication with embossed facets (smooth also available; see Options). Impact-modified, single clear acrylic diffuser provides excellent shielding and wide distribution. End plates include integral T-bar clips. Fixture may be mounted and wired in continuous rows. Total fixture height is only 4-3/8". 2' x 4' T5 or T8 One, two or three lamps OPTICS — Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions, vertical and horizontal work surfaces — rendering the interior space, objects and occupants in a more balanced, complementary luminous environment. Linear faceted reflector cavity softens and distributes light into the space while minimizing luminous contrast between the fixture and ceiling. Sloped end plates provide a smooth, luminous transition between fixture and ceiling while enhancing the perception of fixture depth. ELECTRICAL — Highly efficient program-start electronic ballasts, Class P, thermally protected, resetting, HPF, non-PCB, UL Listed, CSA certified, sound rated A. Luminaire is suitable for damp locations. AWM, TFM or THHN wire used throughout, rated for required temperatures. Step-level dimming option allows system to be switched to 50% power for compliance. (GEB95S) Specifications Ballast disconnect provided where required to comply with US and Canadian codes. Length: 48 (122.0) INSTALLATION — Unique grid interfacing arrangement provides mounting into standard 1" and 9/16" tee bar or screw slot grids. 9/16" allows fixture trim to hang level with architectural ceiling tiles. Width: 24 (61.0) Drywall ceiling adaptors available. LISTINGS— UL Listed to US and Canadian safety standard. 4-3/8 (11.1) Depth: 4-3/8 (11.1) All dimensions are inches (centimeters). 8-1/4 (21) 24 (61.0) Patents pending. WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx. Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. ORDERING INFORMATION Example: 2VT8 2 32 ADP MVOLT GEB10IS LP835 Lead times will vary depending on options selected. Consult with your sales representative. ADP Series Air function 2VT5 T5 2X4 volumetric troffer 2VT8 T8 2X4 volumetric troffer (blank) H Static Heat removal Number of lamps 1 2 3 Ballast GEB10IS GEB10PS GEB95 GEB95S Wattage 32 32W T8 (48") 28T5 28W T5 (46") 54T5HO 54W T5HO (46") Lamp T8 electronic, <10% THD, instant start T5 and T8 electronic, <10% THD, programmed start T5 electronic, <10% THD, .95 ballast factor, programmed start T5 electronic, <10% THD, .95 ballast factor, step dimming, programmed start LP835 80+ CRI, 3500 Kelvin LP841 80+ CRI, 4100 Kelvin LP830 80+ CRI, 3000 Kelvin Accessories: Order as separate catalog number. DGA24 2VT4 F916 FLUORESCENT Drywall ceiling adaptor, unit installation4 Trim to adjust fixture mounting flush with 9/16" T-bar; for 2x4 fixture Diffuser ADP Acrylic linear prismatic Voltage Ballast configuration (blank) MVOLT 3471 1/3 One or two lamps, per Lithonia Lighting standards One, three-lamp ballast2 Options GLR RSW EL14 EL CSA Fast-blow fuse Smooth reflector Emergency battery pack, 1400 lumens Emergency battery pack Meets Canadian standards3 Notes 1. Not available with 32 T8 GEB10PS. 2. Available with 32T8 and 54T5HO only. 3. 347V only. 4 When DGA kits are used order the 2VT2 F916 accessory. 2VT-2X4 Submitting Agency: Description: 2VT8 2 32 ADP MVOLT GEB10IS PWS1836 LP841 Project: Notes: Cascade Periodontics GRID MOUNT; LAMPS AND FLEX INCLUDED Type: A 2VT Volumetric Recessed Lighting 2'x4' PHOTOMETRICS 2VT8 2 32 ADP; 2800 lumens per lamp; s/m 1.2 (along), 1.4 (across); test no. LTL18809. Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10% 0 97 97 97 95 95 95 90 90 90 1 88 83 80 81 78 75 78 75 72 2 79 72 66 70 65 60 67 62 58 3 71 62 55 61 54 49 58 53 48 4 65 55 47 54 46 41 52 45 40 5 60 49 41 48 40 35 46 39 35 6 55 44 36 43 35 30 41 35 30 7 51 39 32 39 32 26 37 31 26 8 47 36 29 35 28 23 34 28 23 9 44 33 26 32 26 21 31 25 21 10 41 30 23 30 23 19 29 23 19 90° 80° 200 400 60° 600 800 1000 40° 1200 0° 20° 0° CP Summary 0° 90 0° 1313 1313 5° 1298 1310 15° 1252 1308 25° 1161 1298 35° 1019 1264 45° 834 1196 55° 617 1081 915 65° 391 586 75° 190 110 85° 40 0 2 90 RCR 180° Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0° - 30° 1058 18.9 23.2 0° - 40° 1778 31.7 39.0 0° - 60° 3342 59.7 73.4 0° - 90° 4555 81.3 100.0 90° - 180° 0 0.0 0.0 0° - 180° 4555 81.3 100.0 Efficiency: 81.3% 90° 2VT5 2 28 ADP; 2600 lumens per lamp; s/m 1.2 (along), 1.4 (across); test no. LTL18909. 90° 80° 200 400 60° 600 800 1000 1200 40° 1400 0° 20° 0° CP Summary 0° 90 0° 1445 1445 5° 1419 1446 15° 1366 1417 25° 1263 1364 35° 1103 1287 45° 895 1184 55° 651 1049 878 65° 403 584 75° 192 94 85° 42 0 3 90 Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10% 0 107 107 107 105 105 105 100 100 100 1 97 93 88 90 87 83 87 83 81 2 88 80 73 78 72 67 75 70 65 3 80 70 62 68 61 55 65 59 54 4 73 61 53 60 52 46 58 51 45 5 67 54 46 53 45 39 51 44 39 6 61 49 40 48 40 34 46 39 34 7 57 44 36 43 36 30 42 35 30 8 53 40 32 40 32 27 38 31 27 9 49 37 29 36 29 24 35 29 24 10 46 34 27 33 26 22 33 26 22 RCR 180° Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0° - 30° 1140 21.9 24.3 0° - 40° 1893 36.4 40.4 0° - 60° 3483 67.0 74.3 0° - 90° 4686 90.1 100.0 90° - 180° 0 0.0 0.0 0° - 180° 4686 90.1 100.0 Efficiency: 90.1% 90° MOUNTING DATA 9/16 9/16 with accessory 2VT4 F916 15/16 Screw Slot 2VT-2X4 FLUORESCENT: One Lithonia Way, Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com © 2010-2014 Acuity Brands Lighting, Inc. All rights reserved. Rev. 11/17/14 Submitting Agency: Type: Description: LB 3 32 MVOLT 1/3 GEB10IS Project: Notes: Cascade Periodontics 1-BALLAST; (3) F32T8 LAMPS--BY OTHERS B Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE For applications that require the clean appearance of a low-profile, brightness-controlled wraparound. Provides broad distribution of light for offices, schools and corridors. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. ATTRIBUTES Curved prismatic diffuser with linear side prisms minimize lamp image and provides high angle brightness control. Luminous end plates soften appearance for improved aesthetics. CONSTRUCTION Metal parts are die formed from code-gauge steel. Prismatic diffuser is 100% acrylic with sonically welded luminous ends. Continuous side flanges on fixture body provide light trap and continuous diffuser support to prevent accidental opening and simplify maintenance. FINISH Five stage iron-phosphate pretreatment assure superior paint adhesion and rust resistance. Painted parts finished with high-gloss, high-reflectivity baked white polyester enamel (low VOC). ELECTRICAL SYSTEM Thermally-protected, resetting, Class P, HPF, non-PCB, UL Listed, CSA Certified ballast is standard. Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. UL/CSA listed ballast disconnect w/strain relief and leads provided standard. LISTING UL Listed (standard). Optional: Canada CSA or C-UL. Mexico NOM. WARRANTY Guaranteed for one year against mechanical defects in manufacture. ORDERING INFORMATION Low-Profile Wraparound LB 3 T5 and T8 3 lamps Wide body 4' or 8' length Specifications T8 Length: 24 (61.00) 48 (122.00) or 96 (243.90) T5 Length: 46.5 (118.1) 22.5 (57.2) Width: 15-3/8 (39.05) Depth: 3 (7.62) H W All dimensions are inches (centimeters) . Specifications subject to change without notice. For shortest lead times, configure product using standard options (shown in bold). Example: LB 3 32 MVOLT GEB10IS LB 3 Series Number of lamps LB 3 lamps, 15-3/8" wide For tandem, double-length unit, add prefix T. Example: TLB 3 Not included Lamp type 32 32W T8 (48") 28 28W T5 (46.5")2 Voltage Options 120 277 347 1/3 One, three-lamp ballast GEB10IS Electronic ballast, <10% THD, instant start MVOLT Others available GEB10PS Electronic ballast, <10% THD, program start EL Emergency battery pack (nominal 300 lumens See Life Safety Section). GLR Internal fast-blow fuse.1 GMF Internal slow-blow fuse.1 LSC Lens safety clips (2 per fixture). LP_ Lamped; specify lamp type and color CSA Listed and labeled to comply with Canadian Standards. SSR Specular silver interior finish (95% reflective). NOTES: 1 Must specify voltage. 2 All T5 lamp types use GEB10PS ballast only. Accessories Order as separate item SQ Swivel-stem hanger (specify in 2" increments). 1B Ceiling spacer (adjusts from 1-1/2" to 2-1/2" from ceiling). Fluorescent Sheet #: LB 3W WRAP-190 Submitting Agency: Type: Description: LB 3 32 MVOLT 1/3 GEB10IS Project: Notes: Cascade Periodontics 1-BALLAST; (3) F32T8 LAMPS--BY OTHERS B LB 3 Low-Profile Wraparound, Wide Body MOUNTING DATA DIMENSIONS For unit or row installation, surface or stem mounting. Stem mounting not available on TLB units. Inches (centimeters). Subject to change without notice. Individual installation — Four single-stem hangers required. Row installation — Two hangers per fixture plus two per row required. A C D E See ACCESSORIES below for hanging devices. = = = = 1/4 x 1/2 (.635 x 1.27) hole 7/8 (2.22) Dia.K.O. 11/16 (1.74) Dia. K.O. 2 (5.08) Dia. K.O. and 7/8 (2.22) Dia. K.O. PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. LB 3 32 Report LTL 5638 – Lumens per lamp = 2900 S/MH (along) 1.2 (across) 1.3 Coefficient of Utilization Ceiling Energy (Calculated in accordance with NEMA standard LE-5) LER.FW 65 80% 70% 50% 0% Wall 70% 50% 30% 70% 50% 30% 50% 30% 10% 0% 0 1 2 3 4 5 6 7 8 9 10 87 80 74 68 63 57 53 49 45 42 39 84 77 71 65 60 55 51 47 44 40 37 87 77 68 61 54 49 44 39 35 32 29 87 74 63 55 48 42 37 33 29 26 23 84 74 66 59 53 47 43 38 35 31 28 84 71 62 54 47 41 37 33 29 25 23 79 70 62 56 50 45 41 37 33 30 27 79 67 59 51 45 40 35 32 28 25 22 79 65 56 48 42 36 32 28 24 21 19 ANNUAL ENERGY COST* LAMP DESCRIPTION LAMP LUMENS BALLAST FACTOR WATTS $3.69 (3) 32W T8 2850 .88 87 *Calculated in accordance with NEMA Standard LE-5. 67 57 49 43 37 32 28 25 22 19 16 Zonal Lumens Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp %Fixture 1786 2935 4808 5835 668 6503 20.5 33.7 55.3 67.1 7.7 74.8 27.5 45.1 73.9 89.7 10.3 100.0 Lithonia Lighting Sheet #: LB 3 W ©2000 Acuity Brands Lighting, Inc., All rights reserved, Rev. 11/16/09 Fluorescent One Lithonia Way, Conyers, GA 30012-3957 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com Catalog Number: CV6-126/32T Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-HSG Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES Project: Fixture Type: Location: Contact/Phone: PRODUCT SPECIFICATIONS DIMENSIONS Lamp One 26W or 32W triple tube compact fluorescent lamp CFTR26W/GX24q-3 or CFTR32W/GX24q-3 • 4 pin electronic. 11 3/4" Socket Housing Vented, extruded aluminum housing with heat dissipating fins • Single-position, keyed reflector attachment. Ballast 120V thru 277V HPF Electronic with end-of-life lamp protection • 347V HPF Electronic available in Canada • Optional Dimming ballast available • U.L. listed/CSA certified. 11 1/2" Trim Ring White, Satin Chrome, or Classic Aged Bronze Polycarbonate • Optional self-flanged trim with same finish as reflector. 9 3/8" Reflector .050” aluminum reflector with low iridescent clear, gold or haze finish • Other finishes including wheat, straw and pewter available on special order basis. Labels U.L. listed for through-branch wiring and damp locations • Product mechanically protected against improper use of lamps • Union made • CSA certified. 6" 7 5/8" Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice. 6 7/8" CEILING CUTOUT ENGINEERING DATA INSTALLATION Mounting Bracket Rough-in section equipped with vertically adjustable mounting brackets that accept 1⁄2” conduit, “C” channels (HB-26 or HB-50), linear flat bars (LB-27) or 26” telescoping Real Nail bar hangers (HB-1). Junction Box Pre-wired junction box provided with (5)1⁄2˝ and (1)3⁄4˝ knockouts, U.L. listed/CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16-gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough-in section (junction box, mounting frame, mounting brackets, ballast and socket assembly) fully assembled for ease of installation • Accommodates 7⁄8˝ ceiling thickness maximum. Total input power 120V-HPF 26W/32W 28W/35W 277V-HPF 26W/32W 28W/35W 347V-HPF Canada 26W/32W 38W/42W Operating AMPS Power Factor T.H.D. .23A/.29A >.98 <10% .10A/.13A >.98 <10% .11A/.12A >.97 <10% Min. starting 0°F/ 0°F/ 0°F/ temperature Crest Factor Ballast Factor -18°C <1.65 >.98 -18°C <1.65 >.98 -18°C <1.65 1.00 ACCESSORIES Catalog No. HB-1 HB-26 HB-50 LB-27 PLK-E Description Two Real Nail Bar Hangers Two 26˝ C-channel bar hangers Two 50˝ C-channel bar hangers Two 27˝ linear bar hangers 13-42W emerg. power kit (Elect. Ballast) To order, specify catalog number. PRODUCT CODES Catalog Number Reflector Finish, Trim Ballast Wattage and Lamp CV6-126/32T-600C-WH CV6-126/32T-600G-WH CV6-126/32T-600HZ-WH CV6-126/32T-600WHZ-WH Low Iridescent Clear Alzak, White Trim Low Iridescent Gold Alzak, White Trim Low Iridescent Haze, White Trim Low Iridescent Wheat Haze, White Trim HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL REV-7/10 OPTIONS (Add as suffix to housing or trim) Catalog No. 347 DB120 DB277 SF Description 347V, HPF Electronic Ballast 120V Dimming Ballast 277V Dimming Ballast Self-Flanged Reflector Ordering Example: CV6-126/32T-347-600C-SF Catalog Number: CV6-126/32T Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-HSG Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT PHOTOMETRIC REPORT Test Report #: PT05991510 Catalog No: CV6-126/32T-600C-WH Total Luminaire Efficiency: 70.7% Luminaire Spacing Criterion: 1.0 Luminaire: Recessed Clear Alzak Reflector Downlight Lamp: One 26W Triple Tube CFL lamp rated @ 1800 lumens 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES LUMINANCE CANDLEPOWER DISTRIBUTION (Candelas) (Average cd/m2) Degrees Vertical Average Average 0 725 Degrees Luminance 5 753 10 778 45 26,500 15 765 20 761 55 1,530 25 729 30 671 65 0 35 585 75 0 40 475 45 342 85 0 50 138 55 16 60 0 65 0 70 0 75 0 80 0 85 0 90 0 *Multipliers: 32W - 1.33, Gold - 0.9, Haze - 0.95 200 400 600 800 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0 - 30° 624 34.7 49.1 0 - 40° 987 54.8 77.5 0 - 60° 1268 70.5 99.7 0 - 90° 1272 70.7 100.0 90 - 180° 0 0 0 0 - 180° 1272 70.7 100.0 COEFFICIENTS OF UTILIZATION– % (Zonal Cavity Method) Effective Floor Cavity Reflectance 20% (ρfc) ρcc 80 70 50 30 10 ρw RCR 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 84 77 71 65 60 55 50 46 43 40 37 84 75 68 61 55 50 45 41 38 35 32 ρcc – Ceiling Cavity Reflectance (%) 84 73 65 58 52 46 42 38 35 32 29 82 76 70 64 59 54 50 46 43 39 37 82 74 67 60 54 49 45 41 38 35 32 82 72 64 57 51 46 42 38 35 32 29 78 73 67 62 57 53 49 45 42 39 36 78 71 65 59 53 49 44 41 37 34 32 78 70 63 56 51 46 41 38 34 32 29 75 70 65 60 56 51 48 44 41 38 35 75 69 63 57 52 48 44 40 37 34 32 75 68 61 55 50 45 41 37 34 31 29 72 68 63 59 54 50 47 43 40 37 35 72 67 61 56 52 47 43 40 37 34 31 0 0 70 65 59 53 48 44 40 36 33 30 28 72 66 60 54 49 45 41 37 34 31 29 ρw – Wall Reflectance (%) INITIAL FOOTCANDLES AVERAGE INITIAL FOOTCANDLES One Unit, 26 Watt, 66° Beam Multiple Units (Square Array, 60’ x 60’ Room) Footcandles Beam Edge Footcandles Beam Center Beam Diameter Distance to Illuminated Plane (Feet) 5.9 20.1 7.9’ 6 3.3 11.3 10.5’ 8 2.1 7.3 13.1’ 10 1.5 5.0 15.7’ 12 1.1 3.7 18.3’ 14 Ceiling 80% Wall 50% Floor 20% Spacing RCR1 RCR3 RCR5 4.0´ 87 73 62 5.0´ 55 47 40 6.0´ 39 33 28 7.0´ 31 26 22 25 21 18 0.8 2.8 21.0’ 16 8.0´ 0.7 2.2 23.6’ 18 9.0´ 19 16 13 0.5 1.8 26.2’ 20 10.0´ 14 12 10 (Beam Edge defined as 50% of Maximum Nadir Candlepower) *Note: Mulitipliers are provided for estimating purposes only. Use IES photometric files for precise photometric information. 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792-7335 • Fax (905) 792-0064 Printed in U.S.A. ©2010 Juno Lighting, LLC. Visit us at www.junolightinggroup.com Catalog Number: 600C-WH Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-TRIM Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES Project: Fixture Type: Location: Contact/Phone: PRODUCT SPECIFICATIONS DIMENSIONS Lamp One 26W or 32W triple tube compact fluorescent lamp CFTR26W/GX24q-3 or CFTR32W/GX24q-3 • 4 pin electronic. 11 3/4" Socket Housing Vented, extruded aluminum housing with heat dissipating fins • Single-position, keyed reflector attachment. Ballast 120V thru 277V HPF Electronic with end-of-life lamp protection • 347V HPF Electronic available in Canada • Optional Dimming ballast available • U.L. listed/CSA certified. 11 1/2" Trim Ring White, Satin Chrome, or Classic Aged Bronze Polycarbonate • Optional self-flanged trim with same finish as reflector. 9 3/8" Reflector .050” aluminum reflector with low iridescent clear, gold or haze finish • Other finishes including wheat, straw and pewter available on special order basis. Labels U.L. listed for through-branch wiring and damp locations • Product mechanically protected against improper use of lamps • Union made • CSA certified. 6" 7 5/8" Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice. 6 7/8" CEILING CUTOUT ENGINEERING DATA INSTALLATION Mounting Bracket Rough-in section equipped with vertically adjustable mounting brackets that accept 1⁄2” conduit, “C” channels (HB-26 or HB-50), linear flat bars (LB-27) or 26” telescoping Real Nail bar hangers (HB-1). Junction Box Pre-wired junction box provided with (5)1⁄2˝ and (1)3⁄4˝ knockouts, U.L. listed/CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16-gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough-in section (junction box, mounting frame, mounting brackets, ballast and socket assembly) fully assembled for ease of installation • Accommodates 7⁄8˝ ceiling thickness maximum. Total input power 120V-HPF 26W/32W 28W/35W 277V-HPF 26W/32W 28W/35W 347V-HPF Canada 26W/32W 38W/42W Operating AMPS Power Factor T.H.D. .23A/.29A >.98 <10% .10A/.13A >.98 <10% .11A/.12A >.97 <10% Min. starting 0°F/ 0°F/ 0°F/ temperature Crest Factor Ballast Factor -18°C <1.65 >.98 -18°C <1.65 >.98 -18°C <1.65 1.00 ACCESSORIES Catalog No. HB-1 HB-26 HB-50 LB-27 PLK-E Description Two Real Nail Bar Hangers Two 26˝ C-channel bar hangers Two 50˝ C-channel bar hangers Two 27˝ linear bar hangers 13-42W emerg. power kit (Elect. Ballast) To order, specify catalog number. PRODUCT CODES Catalog Number Reflector Finish, Trim Ballast Wattage and Lamp CV6-126/32T-600C-WH CV6-126/32T-600G-WH CV6-126/32T-600HZ-WH CV6-126/32T-600WHZ-WH Low Iridescent Clear Alzak, White Trim Low Iridescent Gold Alzak, White Trim Low Iridescent Haze, White Trim Low Iridescent Wheat Haze, White Trim HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL REV-7/10 OPTIONS (Add as suffix to housing or trim) Catalog No. 347 DB120 DB277 SF Description 347V, HPF Electronic Ballast 120V Dimming Ballast 277V Dimming Ballast Self-Flanged Reflector Ordering Example: CV6-126/32T-347-600C-SF Catalog Number: CV6-126/32T Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-EM HSG Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES Project: Fixture Type: Location: Contact/Phone: PRODUCT SPECIFICATIONS DIMENSIONS Lamp One 26W or 32W triple tube compact fluorescent lamp CFTR26W/GX24q-3 or CFTR32W/GX24q-3 • 4 pin electronic. 11 3/4" Socket Housing Vented, extruded aluminum housing with heat dissipating fins • Single-position, keyed reflector attachment. Ballast 120V thru 277V HPF Electronic with end-of-life lamp protection • 347V HPF Electronic available in Canada • Optional Dimming ballast available • U.L. listed/CSA certified. 11 1/2" Trim Ring White, Satin Chrome, or Classic Aged Bronze Polycarbonate • Optional self-flanged trim with same finish as reflector. 9 3/8" Reflector .050” aluminum reflector with low iridescent clear, gold or haze finish • Other finishes including wheat, straw and pewter available on special order basis. Labels U.L. listed for through-branch wiring and damp locations • Product mechanically protected against improper use of lamps • Union made • CSA certified. 6" 7 5/8" Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice. 6 7/8" CEILING CUTOUT ENGINEERING DATA INSTALLATION Mounting Bracket Rough-in section equipped with vertically adjustable mounting brackets that accept 1⁄2” conduit, “C” channels (HB-26 or HB-50), linear flat bars (LB-27) or 26” telescoping Real Nail bar hangers (HB-1). Junction Box Pre-wired junction box provided with (5)1⁄2˝ and (1)3⁄4˝ knockouts, U.L. listed/CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16-gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough-in section (junction box, mounting frame, mounting brackets, ballast and socket assembly) fully assembled for ease of installation • Accommodates 7⁄8˝ ceiling thickness maximum. Total input power 120V-HPF 26W/32W 28W/35W 277V-HPF 26W/32W 28W/35W 347V-HPF Canada 26W/32W 38W/42W Operating AMPS Power Factor T.H.D. .23A/.29A >.98 <10% .10A/.13A >.98 <10% .11A/.12A >.97 <10% Min. starting 0°F/ 0°F/ 0°F/ temperature Crest Factor Ballast Factor -18°C <1.65 >.98 -18°C <1.65 >.98 -18°C <1.65 1.00 ACCESSORIES Catalog No. HB-1 HB-26 HB-50 LB-27 PLK-E Description Two Real Nail Bar Hangers Two 26˝ C-channel bar hangers Two 50˝ C-channel bar hangers Two 27˝ linear bar hangers 13-42W emerg. power kit (Elect. Ballast) To order, specify catalog number. PRODUCT CODES Catalog Number Reflector Finish, Trim Ballast Wattage and Lamp CV6-126/32T-600C-WH CV6-126/32T-600G-WH CV6-126/32T-600HZ-WH CV6-126/32T-600WHZ-WH Low Iridescent Clear Alzak, White Trim Low Iridescent Gold Alzak, White Trim Low Iridescent Haze, White Trim Low Iridescent Wheat Haze, White Trim HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL REV-7/10 OPTIONS (Add as suffix to housing or trim) Catalog No. 347 DB120 DB277 SF Description 347V, HPF Electronic Ballast 120V Dimming Ballast 277V Dimming Ballast Self-Flanged Reflector Ordering Example: CV6-126/32T-347-600C-SF Catalog Number: CV6-126/32T Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-EM HSG Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT PHOTOMETRIC REPORT Test Report #: PT05991510 Catalog No: CV6-126/32T-600C-WH Total Luminaire Efficiency: 70.7% Luminaire Spacing Criterion: 1.0 Luminaire: Recessed Clear Alzak Reflector Downlight Lamp: One 26W Triple Tube CFL lamp rated @ 1800 lumens 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES LUMINANCE CANDLEPOWER DISTRIBUTION (Candelas) (Average cd/m2) Degrees Vertical Average Average 0 725 Degrees Luminance 5 753 10 778 45 26,500 15 765 20 761 55 1,530 25 729 30 671 65 0 35 585 75 0 40 475 45 342 85 0 50 138 55 16 60 0 65 0 70 0 75 0 80 0 85 0 90 0 *Multipliers: 32W - 1.33, Gold - 0.9, Haze - 0.95 200 400 600 800 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixture 0 - 30° 624 34.7 49.1 0 - 40° 987 54.8 77.5 0 - 60° 1268 70.5 99.7 0 - 90° 1272 70.7 100.0 90 - 180° 0 0 0 0 - 180° 1272 70.7 100.0 COEFFICIENTS OF UTILIZATION– % (Zonal Cavity Method) Effective Floor Cavity Reflectance 20% (ρfc) ρcc 80 70 50 30 10 ρw RCR 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 84 77 71 65 60 55 50 46 43 40 37 84 75 68 61 55 50 45 41 38 35 32 ρcc – Ceiling Cavity Reflectance (%) 84 73 65 58 52 46 42 38 35 32 29 82 76 70 64 59 54 50 46 43 39 37 82 74 67 60 54 49 45 41 38 35 32 82 72 64 57 51 46 42 38 35 32 29 78 73 67 62 57 53 49 45 42 39 36 78 71 65 59 53 49 44 41 37 34 32 78 70 63 56 51 46 41 38 34 32 29 75 70 65 60 56 51 48 44 41 38 35 75 69 63 57 52 48 44 40 37 34 32 75 68 61 55 50 45 41 37 34 31 29 72 68 63 59 54 50 47 43 40 37 35 72 67 61 56 52 47 43 40 37 34 31 0 0 70 65 59 53 48 44 40 36 33 30 28 72 66 60 54 49 45 41 37 34 31 29 ρw – Wall Reflectance (%) INITIAL FOOTCANDLES AVERAGE INITIAL FOOTCANDLES One Unit, 26 Watt, 66° Beam Multiple Units (Square Array, 60’ x 60’ Room) Footcandles Beam Edge Footcandles Beam Center Beam Diameter Distance to Illuminated Plane (Feet) 5.9 20.1 7.9’ 6 3.3 11.3 10.5’ 8 2.1 7.3 13.1’ 10 1.5 5.0 15.7’ 12 1.1 3.7 18.3’ 14 Ceiling 80% Wall 50% Floor 20% Spacing RCR1 RCR3 RCR5 4.0´ 87 73 62 5.0´ 55 47 40 6.0´ 39 33 28 7.0´ 31 26 22 25 21 18 0.8 2.8 21.0’ 16 8.0´ 0.7 2.2 23.6’ 18 9.0´ 19 16 13 0.5 1.8 26.2’ 20 10.0´ 14 12 10 (Beam Edge defined as 50% of Maximum Nadir Candlepower) *Note: Mulitipliers are provided for estimating purposes only. Use IES photometric files for precise photometric information. 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792-7335 • Fax (905) 792-0064 Printed in U.S.A. ©2010 Juno Lighting, LLC. Visit us at www.junolightinggroup.com Catalog Number: 600C-WH Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-EM TRIM Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES Project: Fixture Type: Location: Contact/Phone: PRODUCT SPECIFICATIONS DIMENSIONS Lamp One 26W or 32W triple tube compact fluorescent lamp CFTR26W/GX24q-3 or CFTR32W/GX24q-3 • 4 pin electronic. 11 3/4" Socket Housing Vented, extruded aluminum housing with heat dissipating fins • Single-position, keyed reflector attachment. Ballast 120V thru 277V HPF Electronic with end-of-life lamp protection • 347V HPF Electronic available in Canada • Optional Dimming ballast available • U.L. listed/CSA certified. 11 1/2" Trim Ring White, Satin Chrome, or Classic Aged Bronze Polycarbonate • Optional self-flanged trim with same finish as reflector. 9 3/8" Reflector .050” aluminum reflector with low iridescent clear, gold or haze finish • Other finishes including wheat, straw and pewter available on special order basis. Labels U.L. listed for through-branch wiring and damp locations • Product mechanically protected against improper use of lamps • Union made • CSA certified. 6" 7 5/8" Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice. 6 7/8" CEILING CUTOUT ENGINEERING DATA INSTALLATION Mounting Bracket Rough-in section equipped with vertically adjustable mounting brackets that accept 1⁄2” conduit, “C” channels (HB-26 or HB-50), linear flat bars (LB-27) or 26” telescoping Real Nail bar hangers (HB-1). Junction Box Pre-wired junction box provided with (5)1⁄2˝ and (1)3⁄4˝ knockouts, U.L. listed/CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16-gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough-in section (junction box, mounting frame, mounting brackets, ballast and socket assembly) fully assembled for ease of installation • Accommodates 7⁄8˝ ceiling thickness maximum. Total input power 120V-HPF 26W/32W 28W/35W 277V-HPF 26W/32W 28W/35W 347V-HPF Canada 26W/32W 38W/42W Operating AMPS Power Factor T.H.D. .23A/.29A >.98 <10% .10A/.13A >.98 <10% .11A/.12A >.97 <10% Min. starting 0°F/ 0°F/ 0°F/ temperature Crest Factor Ballast Factor -18°C <1.65 >.98 -18°C <1.65 >.98 -18°C <1.65 1.00 ACCESSORIES Catalog No. HB-1 HB-26 HB-50 LB-27 PLK-E Description Two Real Nail Bar Hangers Two 26˝ C-channel bar hangers Two 50˝ C-channel bar hangers Two 27˝ linear bar hangers 13-42W emerg. power kit (Elect. Ballast) To order, specify catalog number. PRODUCT CODES Catalog Number Reflector Finish, Trim Ballast Wattage and Lamp CV6-126/32T-600C-WH CV6-126/32T-600G-WH CV6-126/32T-600HZ-WH CV6-126/32T-600WHZ-WH Low Iridescent Clear Alzak, White Trim Low Iridescent Gold Alzak, White Trim Low Iridescent Haze, White Trim Low Iridescent Wheat Haze, White Trim HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL REV-7/10 OPTIONS (Add as suffix to housing or trim) Catalog No. 347 DB120 DB277 SF Description 347V, HPF Electronic Ballast 120V Dimming Ballast 277V Dimming Ballast Self-Flanged Reflector Ordering Example: CV6-126/32T-347-600C-SF Catalog Number: PLK-E Submitted by CASCADE LIGHTING REPRESENTATIVES Job Name: Type: C-EM PACK Cascade Periodontics Notes: CLRPDX14-23499 P13.1.1 ACULUX® RECESSED DOWNLIGHT 6” VERTICAL CFL, OPEN APERTURE TC Rated, One 26W or 32W Triple Tube CV6-126/32T-600 SERIES Project: Fixture Type: Location: Contact/Phone: PRODUCT SPECIFICATIONS DIMENSIONS Lamp One 26W or 32W triple tube compact fluorescent lamp CFTR26W/GX24q-3 or CFTR32W/GX24q-3 • 4 pin electronic. 11 3/4" Socket Housing Vented, extruded aluminum housing with heat dissipating fins • Single-position, keyed reflector attachment. Ballast 120V thru 277V HPF Electronic with end-of-life lamp protection • 347V HPF Electronic available in Canada • Optional Dimming ballast available • U.L. listed/CSA certified. 11 1/2" Trim Ring White, Satin Chrome, or Classic Aged Bronze Polycarbonate • Optional self-flanged trim with same finish as reflector. 9 3/8" Reflector .050” aluminum reflector with low iridescent clear, gold or haze finish • Other finishes including wheat, straw and pewter available on special order basis. Labels U.L. listed for through-branch wiring and damp locations • Product mechanically protected against improper use of lamps • Union made • CSA certified. 6" 7 5/8" Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice. 6 7/8" CEILING CUTOUT ENGINEERING DATA INSTALLATION Mounting Bracket Rough-in section equipped with vertically adjustable mounting brackets that accept 1⁄2” conduit, “C” channels (HB-26 or HB-50), linear flat bars (LB-27) or 26” telescoping Real Nail bar hangers (HB-1). Junction Box Pre-wired junction box provided with (5)1⁄2˝ and (1)3⁄4˝ knockouts, U.L. listed/CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16-gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough-in section (junction box, mounting frame, mounting brackets, ballast and socket assembly) fully assembled for ease of installation • Accommodates 7⁄8˝ ceiling thickness maximum. Total input power 120V-HPF 26W/32W 28W/35W 277V-HPF 26W/32W 28W/35W 347V-HPF Canada 26W/32W 38W/42W Operating AMPS Power Factor T.H.D. .23A/.29A >.98 <10% .10A/.13A >.98 <10% .11A/.12A >.97 <10% Min. starting 0°F/ 0°F/ 0°F/ temperature Crest Factor Ballast Factor -18°C <1.65 >.98 -18°C <1.65 >.98 -18°C <1.65 1.00 ACCESSORIES Catalog No. HB-1 HB-26 HB-50 LB-27 PLK-E Description Two Real Nail Bar Hangers Two 26˝ C-channel bar hangers Two 50˝ C-channel bar hangers Two 27˝ linear bar hangers 13-42W emerg. power kit (Elect. Ballast) To order, specify catalog number. PRODUCT CODES Catalog Number Reflector Finish, Trim Ballast Wattage and Lamp CV6-126/32T-600C-WH CV6-126/32T-600G-WH CV6-126/32T-600HZ-WH CV6-126/32T-600WHZ-WH Low Iridescent Clear Alzak, White Trim Low Iridescent Gold Alzak, White Trim Low Iridescent Haze, White Trim Low Iridescent Wheat Haze, White Trim HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL 26W or 32W Triple Tube CFL REV-7/10 OPTIONS (Add as suffix to housing or trim) Catalog No. 347 DB120 DB277 SF Description 347V, HPF Electronic Ballast 120V Dimming Ballast 277V Dimming Ballast Self-Flanged Reflector Ordering Example: CV6-126/32T-347-600C-SF Submitting Agency: Description: HH6PL-1X32-E-MVOLT / 6507-CL-WH Project: Notes: Cascade Periodontics (1) F32TRT LAMP--BY OTHERS Type: CW MAXILUME hH6PL CFL HORIZONTAL 6” DOWNLIGHT Architectural DESCRIPTION: 1. LAMP HOLDER - Aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing. 2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Advance Transformer CO, Universal Technologies or Lutron Electronics. TRIM: 6501 REFLECTOR 5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. OPTICS: 6. REFLECTOR - Self-flanged .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - Self-flanged one-piece aluminum with concentric rings. A 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL/UL listed for wet or damp location. Min. Height = 5-3/8” (See trim heights for details) Max. Height =5-1/2” (See trim heights for details) B Trim Aperture = 6-1/8” C Cut-out = 6-3/4” D Trim Outside Diameter = 7-3/8” E Width = 16” F Length = 12-1/2” LISTING: 6 INCH TYPE: architectural C FL h o rizo n tal Hh6PL ❏1x9 ❏1x13 ❏1x18 ❏1x26 ❏1x32 ❏1x42 Energy Star Compliant fixtures ship with electronic Energy Star compliant ballasts. PROJECT NAME: - ITEM SELECTOR: (Please check the boxes below for the option desired) WATTAGE* 1 LAMP ETL/UL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims. BALLAST 2 LAMPS ❏2x9 ❏2x13 ❏2x18 ❏2x26 *See pages 154-167 for base type and wiring diagrams. VOLTAGE ❏ (E)Electronic ❏ (M)Magnetic ❏ (S)Energy Star ❏(DBL) 1 2 Dual Ballast MVOLT (120/277) ❏ ❏ 120 ❏ 277 ❏ 347 EMERGENCY OPTIONS TRIM TYPE & DESCRIPTION REFLEC. ❏ EMG 750 (750 Lum.) ❏ EMG 1300 (1300 Lum.) ❏ INTG 750 (750 Lum.) ❏ ICE-1300 (1300 Lum. ❏ EMG-D-750 (750 Lum.) ❏ INTG-D-750 (750 Lum.) ❏ ICE-1300 (1300 Lum.) ❏ 6501 Reflector ❏ 6502 Baffle/Ref. ❏ 6503 Ref./Fres. Gls. Lns. ❏ 6504 Ref./Pris. Gls. Lns. ❏ 6505 Baffle/Fres. Gls. Lns. ❏ 6506 Baffle/Pris. Gls. Lns. ❏ 6507 Wall Wash ❏ 6508 Crossblade ❏ 6512 Baffle/Frost Gls. Lns. ❏ 6513 Baffle/Tem. Clr. Gls. ❏ CL ❏ WH ❏ SCH** ❏ P ❏ SHZ* ❏ WT 5.6 5.6 5.7 5.7 5.8 5.9 DIMMING 5.10 OTHER OPTIONS ❏ Adv-7 ❏ Adv-10 ❏ Lut-H (FDB) 3 ❏ FUSE ❏ RIF 4 4 11 12 ❏ 6 514 Ref./Frost Gls. Lns. ❏ 6515 Ref./Tem. Clr. Gls. ❏ 6516 Ref./Pris. Plas. Lns. ❏ 6517 Baf./Pris. Plas. Lns. ❏ 6518 Ref./Tem. Clr. Plas. ❏ 6519 Ref./Tem. Clr. Gls. ❏ 6509 Deco Glass Ring ❏ 6510 Double Ring ❏ 6511 Triple Ring GLASS ❏ Blue ❏ Green ❏ Red ❏ Frost (1=1X9W, 2X9W =Available only in Magnetic ) (2=S=Electronic Energy Star Ballast, available in 120V only) (3=Adv-7 not available on HH6PL-1x9, 2x9) (4=Adv-10 and Lut-H(FDB) are not available on HH6PL-1x9, 2x9, HH6PL-1x13, 2x13) (5=See page 154-167 for more details) (6-EMG=Emergency battery pack w/ remote test switch) (7-INTG=Emergency battery pack w/ integral(reflector) test switch) (8-EMG-D=Emergency battery pack w/ remote test switch for damp location) (9-INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (10-ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (11-FUSE=Single slow-blow fuse) (12-RIF=Radio interference filter) REFLECTOR Specifications: hh6PL _____ - _____ - _______ - __________ - ______ - ______ - _____ - ____ - ____ - ____ Watt ballast voltage emergency options trim type Sample of Catalog Number: Hh6PL-1x32-e-MVOLT-EMG750-6501-CL-WH 116 ❏W ❏ MB BAFFLE reflec. baffle ring glass CL Clear SHZ Satin Haze (Low Iridescent) WT Wheat MB Black W White baffle WH White P Black glass Only available on XX09, XX10 and XX11 series. RING WH Self-Flange White Standard on all trims SCH** Self-Flange Chrome ** Only available on XX01 CL SHZ* Satin Haze * Provided w/ satin haze ring only *For custom baffle, reflector, trim ring, glass color and lens options, please consult factory. www.maxilume.com • tel 1-877-375-5555 • fax 1-877-375-3333 Submitting Agency: Description: HH6PL-1X32-E-MVOLT / 6507-CL-WH Project: Notes: Cascade Periodontics (1) F32TRT LAMP--BY OTHERS MAXILUME Architectural 6501-CL REFlector finish: CL, Wt, MB, SHZ, w RING finish: A= 5-1/2” B= 7-3/8” C= 1” A= 5-1/2” B= 7-3/8” C= 1” blue, red, green, frost 6510-CL* double ring glass A= 5-1/2” B= 7-3/8” C= 1” baffle finish: wh, p CL, Wt, MB, SHZ, w RING finish: Wh, shz, sch A= 5-1/2” B= 7-3/8” C= 1-1/2” glass finish: blue, red, green, frost 6511-CL* triple ring glass A= 5-1/2” B= 7-3/8” C= 1” baffle finish: wh, p REFlector finish: CL, Wt, MB, SHZ, w RING finish: RING finish: Wh, shz, sch Wh glass finish: *Also available in: TEMPERED CLEAR PLASTIC (6519) When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG REFlector finish: www.maxilume.com A= 5-1/2” B= 7-3/8” C= 2-1/4” architectural C FL h o riz o n tal O P TI C S TEMPERED CEAR PLASTIC (6518) A= 5-1/2” B= 7-3/8” C= 1-1/4” glass finish: bafFLE w/ tem. clear glass A= 5-1/2” B= 7-3/8” C= 1” CL, Wt, MB, SHZ, w Wh, shz, sch 6513-WH REFLECTOR w/ tem. clear glass REFlector finish: RING finish: Wh 6515-WT Wh *Also available in: wh, p RING finish: Wh RING finish: A= 5-1/2” B= 7-3/8” C= 1” baffle finish: 6 INCH RING finish: CL, Wt, MB, SHZ, w deco glass reflector bafFLE w/ frosted gl. lens A= 5-1/2” B= 7-3/8” C= 1” A= 5-1/2” B= 7-3/8” 6509-CL* 6512-WH REFLECTOR w/ frosted gl. lens CL, Wt, W, SHZ Wh prismatic PLASTIC LENS (6517) 6514-CL REFlector finish: RING finish: RING finish: prismatic PLASTIC LENS (6516) REFlector finish: wh, p Wh *Also available in: Wh *Also available in: CL, Wt, MB, SHZ, w A= 5-1/2” B= 7-3/8” C= 1” baffle finish: bafFLE w/ pris. glass lens RING finish: REFlector finish: crossblade REFLECTOR 6506-WH REFLECTOR w/ pris. glAsS lens A= 5-1/2” B= 7-3/8” 6508-CL Wh 6504-CL CL, Wt, MB, SHZ, w Wh, sch, SHZ RING finish: Wh REFlector finish: RING finish: bafFLE w/ fres. glASS lens RING finish: CL, Wt, MB, SHZ, w Wh, p 6505-P REFLECTOR w/ fres. glASS lens REFlector finish: A= 5-1/2” B= 7-3/8” C= 1” baffle finish: CL 6503-CL CL, Wt, MB, SHZ, w wall wash REFLECTOR REFlector finish: Wh, SCH, SHZ REFlector finish: 6507-SHZ baffle w/ REFLECTOR A= 5-1/2” B= 7-3/8” CW 6” HORIZONTAL CFL OPTICS 6502-WH-CL REFLECTOR Type: blue, red, green, frost 117 Submitting Agency: Description: HH6PL-1X32-E-MVOLT / 6507-CL-WH Project: Notes: Cascade Periodontics (1) F32TRT LAMP--BY OTHERS BPHOTOMETRIC DATA I CFL I 6” DOWNLIGHTNG Zonal Lumens Summary Zone 0-300 0-400 0-600 0-900 90-1200 90-1300 90-1500 90-1800 0-1800 90° 80° 151 70° 302 60° 50° 453 40° 30° 604 10° 0° 11.3’ 17.0’ RC RW 12’ 4 34.0’ Room Cavity Ratio 35.6 15.8 8.9 5.7 Distance to Plane Luminance Data (cd/sq.m) %Fixt 43.1 66 96.5 100 0 0 0 0 100 Angle In Average Degrees 00 450 550 650 750 850 20212 4956 872 610 1208 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 109° 8’ 10’ %Lamp 26.8 41.1 60.1 62.2 0 0 0 0 62.2 Average 450 20212 4956 872 610 1208 Average 900 20212 4956 872 610 1208 22.6’ 28.3’ Initial Nadir Footcandles Beam Spread BEAM DIA. MEASURED AT 10% OF NADIR F.C. Zonal Lumen Summary Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 45.13 169.26 243.79 244.69 236.3 87.81 28.93 5.15 3.24 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 74 70 65 60 56 52 49 46 43 40 38 74 67 61 55 50 46 42 38 35 33 30 74 66 58 51 46 41 37 34 31 28 26 74 64 55 48 43 38 34 31 28 25 23 70% 70% 50% 30% 10% 72 68 63 59 55 51 48 45 42 39 37 RC - Ceiling Cavity Reflectance 72 66 60 54 50 45 41 38 35 32 30 72 64 57 51 45 41 37 34 31 28 26 72 63 55 48 42 38 34 30 28 25 23 50% 50% 30% 10% 69 64 58 53 48 44 40 37 34 32 29 69 62 55 50 45 40 36 33 30 28 26 69 61 53 47 42 37 33 30 27 25 23 30% 50% 30% 10% 66 61 56 51 47 43 39 36 34 31 29 66 60 54 49 44 40 36 33 30 27 25 66 59 52 46 41 37 33 30 27 25 23 10% 50% 30% 10% 64 59 54 50 46 42 38 35 33 31 28 64 58 53 47 43 39 35 32 30 27 25 64 57 51 46 41 37 33 30 27 25 23 0% 0% 62 56 50 44 40 35 32 29 26 24 22 Zonal Lumens Summary Candle Power Distribution (Candelas) Zone 0-300 0-400 0-600 0-900 90-1200 90-1300 90-1500 90-1800 0-1800 90° 80° 194 70° 388 60° 50° 582 40° 30° 10° 0° RC RW Beam Angle: 110° 11.3’ 5.1 34.0’ Distance to Plane Initial Nadir Footcandles 17.0’ 22.6’ 28.3’ Room Cavity Ratio 20.4 11.5 7.3 Beam Spread BEAM DIA. MEASURED AT 10% OF NADIR F.C. 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 74 70 65 61 56 52 49 46 43 40 38 74 67 61 55 50 46 42 38 35 33 30 74 66 58 51 46 41 37 34 31 28 26 74 64 55 48 43 38 34 31 28 25 23 Luminance Data (cd/sq.m) %Fixt 43 66 96.5 100 0 0 0 0 100 70% 70% 50% 30% 10% 72 68 64 59 55 51 48 45 42 39 37 RC - Ceiling Cavity Reflectance Angle In Average Degrees 00 450 550 650 750 850 26019 6425 1121 814 1208 Average 450 26019 6425 1121 814 1208 Average 900 26019 6425 1121 814 1208 Zonal Lumen Summary Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 58.01 217.69 313.7 314.8 304.23 113.13 37.47 6.69 3.78 72 66 60 54 50 45 41 38 35 32 30 72 64 57 51 45 41 37 34 31 28 26 72 63 55 48 42 38 34 30 28 25 23 50% 50% 30% 10% 69 64 58 53 48 44 40 37 34 32 29 69 62 55 50 45 40 36 33 30 28 26 69 61 53 47 42 37 33 30 27 25 23 30% 50% 30% 10% 66 61 56 51 47 43 39 36 34 31 29 66 60 54 49 44 40 36 33 30 27 25 66 59 52 46 41 37 33 30 27 25 23 10% 50% 30% 10% 64 59 54 50 46 42 38 35 33 31 28 64 58 53 47 43 39 35 32 30 27 25 64 57 51 46 41 37 33 30 27 25 23 0% 0% 62 56 50 44 40 35 32 29 26 24 22 Zonal Lumens Summary Candle Power Distribution (Candelas) Zone 0-300 0-400 0-600 0-900 90-1200 90-1300 90-1500 90-1800 0-1800 90° 80° 282 70° 565 60° 50° 847 40° 30° 1129 0° 10° Lumens 857.26 1315.19 1922.41 1992.4 0 0 0 0 1992.4 %Lamp 26.8 41.1 60.1 62.3 0 0 0 0 62.3 Luminance Data (cd/sq.m) %Fixt 43 66 96.5 100 0 0 0 0 100 Angle In Average Degrees 00 450 550 650 750 850 37856 9361 1619 1220 1812 Average 450 37856 9361 1619 1220 1812 Average 900 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW Beam Angle: 110° 4’ 6’ 8’ 10’ 12’ 66.6 29.7 16.7 11 7.4 11.3’ 17.0’ 22.6’ 28.3’ 34.0’ Distance to Plane Initial Nadir Footcandles Beam Spread 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 74 70 65 61 56 52 49 46 43 40 38 74 68 61 55 50 46 42 38 35 33 30 74 66 58 51 46 41 37 34 31 28 26 74 64 55 48 43 38 34 31 28 25 23 RC - Ceiling Cavity Reflectance Candela Tabulation 0 1 3 5 7 9 11 13 15 17 19.5 22.5 25.5 29 33 37.5 42.5 47.5 55 65 75 85 90 0 733 737 742 748 753 757 760 764 771 776 775 756 726 689 626 542 416 283 70 9 4 2 0 37856 9361 1619 1220 1812 70% 70% 50% 30% 10% 72 68 64 59 55 51 48 45 42 39 37 72 66 60 54 50 45 41 38 35 32 30 72 64 57 51 45 41 37 34 31 28 26 72 63 55 48 42 38 34 30 28 25 23 50% 50% 30% 10% 69 64 58 53 48 44 40 37 34 32 29 69 62 56 50 45 40 36 33 30 28 26 69 61 53 47 42 37 33 30 27 25 23 30% 50% 30% 10% 66 61 56 51 47 43 39 36 34 31 29 66 60 54 49 44 40 36 33 30 27 25 66 59 52 46 41 37 33 30 27 25 23 Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 84.37 316.58 456.31 457.93 442.49 164.73 54.54 9.78 5.68 10% 50% 30% 10% 64 59 54 50 46 42 38 36 33 31 28 64 58 53 47 43 39 35 32 30 27 25 test no.: LLI 0509-15P-P spacing criteria: 1.26 Zonal Lumen Summary Total Luminaire Efficiency = 20° 0 570 573 577 582 586 589 591 594 599 604 602 587 565 535 487 421 323 220 54 7 3 2 0 RW - Wall Reflectance hh6pl-1x42-e-6501-cl / bhhr6pl-1x42-e-6501-cl / hhr6pl-1x42-e-6501-cl / hhj6pl-1x42-e-6501-cl/ hh6pl-1x42-e-6501-cl lamp: GE F42TBX/841/A/ECO lumens: 3200 total luminaire efficiency: 62.3% Room Cavity Ratio PHOTOMETRIC DATA C F L D O W NL I G H T 45.8 BEAM DIA. MEASURED AT 10% OF NADIR F.C. 130 %Lamp 26.8 41.1 60.1 62.3 0 0 0 0 62.3 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF 4’ 6’ 8’ 10’ 0 1 3 5 7 9 11 13 15 17 19.5 22.5 25.5 29 33 37.5 42.5 47.5 55 65 75 85 90 test no.: LLI 0509-15P-P spacing criteria: 1.26 Total Luminaire Efficiency = 20° 12’ Lumens 589.4 904.2 1321.56 1369.5 0 0 0 0 1369.5 Candela Tabulation RW - Wall Reflectance hh6pl-1x32-e-6501-cl / bhhr6pl-1x32-e-6501-cl / hhr6pl-1x32-e-6501-cl / hhj6pl-1x32-e-6501-cl/ hh6pl-1x32-e-6501-cl lamp: GE F32TBX/841/A/ECO lumens: 2200 total luminaire efficiency: 62.2% 776 test no.: LLI 0509-15P-P spacing criteria: 1.26 Total Luminaire Efficiency = 62.2% 20° 4’ 6’ Lumens 458.19 702.88 1026.99 1064.31 0 0 0 0 1064.31 CW MAXILUME Architectural hh6pl-1x26-e-6501-cl / bhhr6pl-1x26-e-6501-cl / hhr6pl-1x26-e-6501-cl / hhj6pl-1x26-e-6501-cl/ Ch6pl-1x26-e-6501-cl lamp: GE F26TBX/841/A/ECO lumens: 1710 total luminaire efficiency: 62.2% Candle Power Distribution (Candelas) Type: 64 57 51 46 41 37 33 30 27 25 23 0% 0% 62 56 50 44 40 35 32 29 26 24 22 RW - Wall Reflectance www.maxilume.com • tel 1-877-375-5555 • fax 1-877-375-3333 Candela Tabulation 0 1 3 5 7 9 11 13 15 17 19.5 22.5 25.5 29 33 37.5 42.5 47.5 55 65 75 85 90 0 1066 1072 1079 1088 1095 1101 1105 1111 1121 1129 1127 1100 1056 1002 911 788 605 412 102 13 6 3 0 Submitting Agency: Description: WC 2 17 MVOLT GEB10IS Project: Notes: Cascade Periodontics (2) F17T8 LAMPS--BY OTHERS Type: D2 Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — For wall or ceiling mounting - vertical or horizontal. Ideal for stairwells, corridors, lavatories or any utility application. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. Type Commercial Wall Bracket CONSTRUCTION — Easy maintenance design for individual or tandem mounting. For row mounting, order RMT option. WC Heavy-duty code grade steel. Metal parts are die-formed. Finish: Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Standard finish is high-gloss, high reflectivety, baked white polyester (architectural black available). OPTICS — Available with high performance A12 pattern clear acrylic or low brightness matte white opal acrylic. Front metal fascia eliminates direct illumination. Provides up/down distribution. ELECTRICAL — AWM, TFN or THHN wire used throughout, rated for required temperatures. UL/CSA Ballast disconnect provided where required to comply with US and Canadian codes. T5 and T8 2', 3' or 4' Lengths 1 or 2 Lamps INSTALLATION — End caps spring-loaded for easy diffuser removal. LISTINGS — UL Listed to US and Canadian safety standards. Optional: Mexico NOM. WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. Specifications Length: 24 (609), 36 (914) or 48 (1218) Width: 4-5/8 (118) Depth: 4-9/16 (116) Weight: 14 lbs (6.3 kg) All dimensions are inches (millimeters) unless otherwise indicated. ORDERING INFORMATION Example: WC 2 32 120 MVOLT GEB10IS For shortest lead times, configure product using standard options (shown in bold). WC Series WC All purpose wall bracket Number of lamps Lamp type Diffuser type Voltage Options 1 2 (blank) Matte white opal acrylic A12 #12 pattern acrylic FAC Matte white opal acrylic with front metal fascia FA12 #12 pattern acrylic with front metal fascia 120 277 347 MVOLT CO S1 17 25 32 14T5 21T5 28T5 24T5HO 39T5HO 54T5HO 17W T8 (24") 25W T8 (36") 32W T8 (48") 14W T5 (24") 21W T5 (36") 28W T5 (48") 24W T5HO (24") 39W T5HO (36") 54W T5HO (48") Grounded convenience outlet, 120V only (bottom right)1 Pull-chain switch; installed bottom left; on/off operation of all lamps only (120V only)1 GEB10IS Electronic ballast, ≤ 10% THD, instant-start GEB10PS T5 and T8 electronic ballasts, ≤ 10% THD, programmed start MB Architectural black finish RMT Row mount2 CSA CSA Certified. EL Emergency battery pack (nominal 300 lumens; see Life Safety Section)3 Notes 1 For optional locations, consult factory. 2 Includes continuous row joiner band. Not available with CSA; models requiring CSA labeling ship standard with joiner band. Cannot field install. 3 Not available on 2ft. FLUORESCENTWC Submitting Agency: Description: WC 2 17 MVOLT GEB10IS Project: Notes: Cascade Periodontics (2) F17T8 LAMPS--BY OTHERS Type: D2 WC Wall Bracket, All Purpose MOUNTING DATA DIMENSIONS All dimensions are inches (millimeters) unless otherwise indicated. C = 7/8 (22) Dia. K.O. D = 11/16 (18) Dia. K.O. E = 2(51) Dia. K.O. G = 1-1/8 (29) Dia. K.O. PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Vertical and horizontal illuminance is calculated with fixture mounting 7' above floor. Reflectances 80/50/20%. Full photometric data available upon request. WC 2 32 Report LTL 5736 Initial point illuminance on wall and horizontal work surface (fc) X and Y coordinates are on 12" centers. X 9 8 7 6 Vert. 5 4 3 2 1 Y 1 2 3 4 5 Horiz. 6 7 8 9 10 11 12 13 A 3 3 2 2 2 2 2 1 1 B 4 4 3 3 2 2 2 2 2 C 6 6 3 5 4 3 2 2 2 D 11 18 E 15 31 F 16 33 G 15 31 H 11 18 16 6 4 3 2 2 I 6 6 3 5 4 3 2 2 2 J 4 4 3 3 3 2 2 2 2 K 4 3 2 2 2 2 2 1 1 16 6 3 3 2 2 28 8 4 3 2 2 30 9 4 3 2 2 28 8 4 3 2 2 6 6 6 7 6 6 5 5 5 4 3 3 2 7 7 7 7 7 7 6 5 5 4 3 3 2 8 8 8 8 8 7 6 6 5 4 4 3 3 9 10 10 10 9 9 7 6 6 4 4 4 3 10 11 11 11 10 9 7 7 6 5 4 4 3 10 11 11 11 10 9 7 7 6 5 4 4 3 10 11 11 11 10 9 7 7 6 5 4 4 3 9 10 10 10 9 9 7 6 6 4 4 4 3 8 9 9 9 9 8 7 6 6 4 4 4 3 6 7 7 8 7 7 6 5 5 4 3 3 2 5 6 7 7 7 6 5 5 5 4 3 3 2 WC FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com © 2000-2013 Acuity Brands Lighting, Inc. All rights reserved. Rev. 10/31/2013 BREWMASTER® FP10/20 – Pulley Unit FP1280 – Motor INSTALLATION REQUIREMENTS: It is recommended that each fan and motor assembly have 3/4˝ plywood backing secured to a structural member for adequate support. Each fan assembly consists of 1 motor and 1 pulley/blade assembly. Motor unit can operate a maximum of 4 pulley/blade assemblies—will result in reduced rpm. Not recommended for sound-sensitive areas. Call technical support for more information. ELECTRICAL REQUIREMENTS: 120 VAC, 60 Hz, 15 amp circuit, 15 amp electrical feed, centered under motor unit. MOTOR SPECS: FK2100 motor is designed for optimal performance with this fan. 220 VAC, 50 Hz export version available. BLADES: Blade sets consist of 2 blades—sold separately. Blades are available in reversible oak/walnut, cherrywood, rosewood, natural palm and woven bamboo. See our catalog or visit www.fanimation.com for additional information on these blade options. Note: Fan speeds will vary according to blade set—material, shape and size of blade. In general, smaller blades will turn faster than bigger ones and narrower blades will turn faster than wider ones. CONTROL OPTIONS: TR20WH hand-held remote control with wall mount is included. Push button remote control has 3 fan speeds, infinite light levels, reverse and off button. Instructions are provided with each control. LIGHTING OPTIONS: Optional lighting fitters and light kits are available. To be mounted on motor switch cap housing only. Installation instructions are provided with each lighting fitter and light kit. See our catalog or visit www.fanimation.com for available lighting options. LOCATION USE: Fan is rated for dry locations only. Damp location rated with use of black finish fan components and BMD4A blade set. BREWMASTER® Short Neck Fan Assembly 5¾˝ from ceiling to center of double pulley NOTE: Pulley height may be adjusted *15˝ Short Fan Assembly FP10** *NOTE: All other dimensions are identical to FP20 Long Fan Assembly *17½˝ **Insert Finish Codes NOTE: Motor may be mounted at either end or in the middle. Available Finishes AB Antique brass BL Black PW Pewter Ordering Information (Items Sold Separately) Item Motor Unit with Long Neck Fan Assembly Fan Speed (RPM) High Medium Low OneFP10** TwoFP10** ThreeFP10** FourFP10** FP10** One Motor Unit FP1280** Three-speed, reversible 1-splice/hardware kit TR20WH remote control 1-mounting hardware bag FP1022 Reversible oak/walnut FP1026 Cherrywood FP1030 Rosewood (glossy) Short Fan Assembly 93 75 104 60 46 89 46 35 Blade Sets (sold separately) 28 See catalog or www. fanimation.com for additional blade options 38 NOTE: The RPM’s are approximate and may vary by fan and application. Description 1-short pulley assembly 30 ft. of 3/8˝ belt 2-traditional blade holders 2-wood blade holders 4-hardware bags 125 76 Catalog No. **Insert Finish Codes BREWMASTER® Long Neck Fan Assembly Long Fan Assembly - FP20** A Overall Length 14´ Max - 4´ Min B Fan Base Length 12˝ C Fan Base Width 4˝ D Overall Drop 26˝ E Blade Sweep 56˝* F Motor Base Diameter 8˝ G Motor Assembly Height 10˝ † Motor Unit FP1280** FK-2100 Motor: 120 volt, 60 Hz, 0.90 amps. Ceiling mount. Remote Control Receiver included (in Switch Cap). Not recommended for sound-sensitive areas. Finishes: available in antique brass, black and pewter C **Insert Finish Codes *Wood Blades (22˝ palm or bamboo - 50˝) B 5¾˝ from ceiling to center of double pulley NOTE: Pulley height may be adjusted † Maximum distance between motor and fan pulley is 14´, maximum distance between two fan pulley assemblies is 13½´ A D F E G NOTE: Motor may be mounted at either end or in the middle. Ordering Information (Items Sold Separately) Item Motor Unit with Long Neck Fan Assembly Fan Speed (RPM) High Medium Low OneFP20** TwoFP20** ThreeFP20** FourFP20** 125 93 75 104 60 46 89 46 35 76 38 28 NOTE: The RPM’s are approximate and may vary by fan and application. Catalog No. Description FP20** 1-long pulley assembly 30 ft. of 3/8˝ belt 2-traditional blade holders 2-wood blade holders 4-hardware bags One Motor Unit FP1280** Three-speed, reversible 1-splice/hardware kit TR20WH remote control 1-mounting hardware bag Blade Sets (Order Separately) FP1022 Reversible oak/walnut FP1026 Cherrywood FP1030 Rosewood (glossy) Long Fan Assembly See catalog or www. fanimation.com for additional blade options **Insert Finish Codes Submitting Agency: Type: Description: AFN DB EXT Project: Notes: Cascade Periodontics LAMPS INCLUDED G Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — Provides a minimum of 90 minutes illumination for the rated wattage upon loss of AC power. Ideal for applications requiring low-profile, attractive emergency lighting. CONSTRUCTION — Compact, low-profile, architectural design with die-cast aluminum housing. Available finishes are texturized polyester powder coat paint in brushed nickel, white, black and dark bronze. All finishes can be painted in the field to match the wall color of choice. U.S. Patent No. D468,046. OPTICS — Standard optics provided with two 6W wedge-base xenon lamps offer 55 percent more light output than standard incandescent lamps. Patent-pending reflector/refractor design features superior vac-metalized, die-casted reflectors; and multi-faceted, highly transmissive refractor that significantly improve photometrics. Forward throw (FWD) option optics provided with two high-brightness white LEDs (10.8W total), projecting an NFPA-101 compliant path 3' wide and 28' forward, when mounted 8-1/2' AFF. The typical life of the LED lamp is 10 years. All light sources meet requirements for NEC 700.16. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Universal J-box mounting pattern. Low-profile, integrated test switch/pilot light located below the lens. Easily visible green status indicator. Rigid conduit entry provision on top of the unit. Battery: Sealed, maintenance-free lead-calcium battery provides 12W rated capacity. Nickel-cadmium battery with Premium and Exterior option packages. Automatic 48-hour recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection. ELECTRICAL — Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal. EXT option package includes 20-minute time delay for supplemental lighting during HID startup. Self-diagnostics (PREM and EXT option packages) Patented Electronics - U.S. Patent No. D468,046 and 6,502,044. ORDERING INFORMATION Type ® Die-Cast Architectural Emergency Light AFN White Brushed Nickel Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Continuously monitors AC functionality. Postpone automatic test initiates eight hour delay of an automatic test by activating the manual test switch. LISTINGS — UL Listed. Wet locations and cold temperature (EXT) listed. Damp location (PREM) listed. Wet location (WL) option available with PREM package. Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. UL labeled. WARRANTY — 3-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. Example: AFN W EXT For shortest lead times, configure product using bolded options. F AFN Series AFN Finish AFFINITY Series die-cast architectural emergency lighting W B BN DB Options White Black Brushed nickel Dark bronze (blank) Features lead calcium battery PREM Features ni-cad battery, self-diagnostics and damp location 32°F to 122°F (0° C to 50°C) EXT Features high-temperature ni-cad battery listed from 0°F to 122°F (-18°C to 50°C), self-diagnostics, time delay; listed for cold weather, damp and wet location FWD Forward throw optics with LED light source, 10.8W WL Wet location with time delay listed from 32°F to 122°F (0°C to 50°C) 1 Accessories: Order as separate catalog number. 2 ELA AFNR DB EMERGENCY Remote fixture (less batteries and electronics) to be powered by 6V battery equipment as part of an emergency lighting system (listed from -40°F to 122°F; -40°C to 50°C), BN, W, B finishes available. Notes 1 WL only available with PREM option package. 2 See spec sheet ELA-OMC-ELA-AFNR. AFN Submitting Agency: Type: Description: AFN DB EXT Project: Notes: Cascade Periodontics LAMPS INCLUDED G AFN Affinity® Die-Cast Architectural Emergency Light MOUNTING SPECIFICATIONS All dimensions are inches (centimeters). Shipping weight: 3.5 lbs. (1.59 kgs.) ELECTRICAL: Primary Circuit Type Volts 120 277 120 277 120 277 AFN AFN PREM AFN EXT AC Input Amps .11 .12 .15 .14 .23 .25 Watts 1.1 1.3 1.4 1.4 211 351 Output volts Watts output 1-1/2 hrs. 6 12 6 12 6 12 2-3/4 (6.9) 4-3/8 (18.6) 4-3/8 (18.6) 9-1/2 (24.1) 9-1/2 (24.1) 9-1/2 (24.1) BATTERY: Sealed Lead-Calcium Voltage Shelf life2 Typical life2 Maintenance4 6 12 months 5 - 7 years none 6-1/2 (16.5) Optimum temperature3 60°– 90°F (16°– 32°C) 6-1/2 (16.5) Test switch status indicator FIXTURE PERFORMANCE Center-to-Center Spacing on a 3-foot Path of Egress BATTERY: Nickel-Cadmium Voltage Shelf life2 Typical life2 Maintenance4 6 3 years 7 - 9 years none Optimum temperature3 32°– 122°F (0°– 50°C) 26 ft . 1 FC average Notes 1 EXT provided with battery heater. 0.1 FC min. 2 At 77°F (25°C). 3 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. See option packages for expanded temperature ranges. Consult factory for detailed information. 3 ft. 4 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. Center-to-Center Spacing on a 6-foot Path of Egress 21 ft. 1 FC average 0.1 FC min. 6 ft. AFFINITY® FWD SPACING GUIDE Xenon Lamp Center-to-Center Spacing Path of Egress 3'-wide 26' Path of Egress 6'-wide 1 FC average 0.1 FC min. 8.5' 21' 20' NOTE: Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 8.5', ceiling height: 9', and reflectances: 80/50/20. 6' 3' 28' AFN EMERGENCY: One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com © 2003-2014 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/28/14 Submitting Agency: Description: HOLOPHANE 24I-42CFL-12-L-K-2-HK Project: Notes: Cascade Periodontics (1) F42TRT LAMP--BY OTHERS Type: H Submitting Agency: Description: HOLOPHANE 24I-42CFL-12-L-K-2-HK Project: Notes: Cascade Periodontics (1) F42TRT LAMP--BY OTHERS Type: H Submitting Agency: Description: 10CRM4 2 32 WHR 20/80 SBL 4FT R4 120 GEB10 SCT F2/48 LP841 C210 ACG Project: Notes: Cascade Periodontics 4' LENGTH; LAMPS INCLUDED Type: L4 Type: ________________________ Cerra 10 I/D Project: ______________________ Indirect-Direct T8 SCEP Option Suspended S P E C I F I C AT I O N S ________ _______ ________ ________ ________ ________ ________ ________ ________ 10CRM4 ________ ________ ________ ________ ________ _____ ________ ________ _____________________ LAMPING OPTIONS 10CRM4 - 1 10CRM4 - 2 10CRM4 - 3 2 5⁄8” 2 5⁄8” 10” 2 5⁄8” 10” 10” SPECIFICATIONS Construction Nominal 10” x 3” crescent housing is formed from one-piece cold-rolled steel. Flat end plate standard. Sculptured die-cast aluminum end cap is optional. Reflectors Die-formed highly reflective white or specular reflector. fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed. Shielding SSB—Parabolic aluminum baffle with semi specular finish. SBL—Steel straight blade baffle. PPL—Perforated steel straight blade baffle. WPB—Parabolic aluminum baffle with white finish. Luminaire Length 4’, 8’, and 12’ lengths in a single section for nominal suspension spacing of 4’, 8’, and 12’. For total luminaire length, add 1⁄16” for each flat end plate or 4” for each sculptured end cap. Using internal joiners, 4’, 8’, and 12’ sections can be joined to form longer length luminaires. Finish Fine-textured, white or aluminum polyester powder paint. Custom colors available, consult factory. Electrical Specify 120V, 277V or 347V. Pre-wired with 16AWG CATALOG NUMBER Examples: 10CRM4 2 32 WHR SSB 40FT R12 277 GEB10 DCT LP835 F1/18 C210 SCEP — 10CRM4 3 32 20/80 PPL 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110 _______ ________ Luminaire # of Lamps 10CRM4 in Cross Section _______ __________ __________ _________ _________ __________ _________ __________ Lamp Type Distribution1 Shielding Baffle Ballast Type WHR White Reflector (Standard) SPRSpecular 40/60 40% Up, 60% Down 20/80 20% Up, 80% Down 0/100 0% Up, 100% Down CLI2 Center Lamp Isolator (Blank) No diffuser OPD Standard Brightness Diffuser SSB SBL Maximum Section Length Voltage 32 Luminaire Row Length 120 277 347 GEB10 <10% THD Electronic ADEZ3 Advance Mark 10 dim DMHL3D3 Lutron Hi-Lume dim ADZT3Advance Mark 7 0-10V dim 32W T8 1 2 3 __________ # of Emergency Modules (Blank)None 1SE 1 section 2SE 2 sections XSE X sections Notes: Semi specular White steel blade X FT PPLWhite (4’ increments) perforated steel baffle WPB White Baffle (pre-finished or painted) ________________ _________ ________________ ______________ ______________ Emergency Type4 Switching Lamp Color Mounting Type SCTSingle circuit DCTDual circuit L/LP No lamp L/LPENo lamp. Wired for energy saving lamps. LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI F1/ (Blank)None ECEmergency circuit EL3 Emergency battery pack EN3Emergency battery pack w/night light circuit 1 Refer to photometric test for exact distribution 2 Available with 3-lamp cross section only 3 Not available in 347V / T-bar ceiling (universal mounting bracket) F1A/ T-bar ceiling (UMB with integrated J-box) F2/ Hard ceiling (horizontal J-box) F3/ Rigid stem Reference Lamp Chart on website or consult factory for other options. Overall Suspension 1212” 1515” 1818” 2121” 2424” XXXX” Overall suspension is measured from ceiling to bottom of luminaire. 4 EL and EC are installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified R4 R8 R12 4’ section(s) 8’ section(s) 12’ section(s) Reference Ballast Wizard on website or consult factory for other options. ______________ _________________________________ Finish Options C110Painted aluminum (low gloss) C210 White white (fine-textured low gloss) C099 Custom finish ACG BLK Adjustable cable grippers Black cord, cord manager and canopy (not available with F3) CP Chicago plenum (available with F1A only) DL Damp location label DU Dust cover ELH Emergency through wiring w/separate feed ELS Emergency through wiring w/single feed, shared neutral ELS2 Emergency through wiring w/single feed, separate neutrals GLR Fusing (fast blow) GMF Fusing (slow blow) MCS Matching feed canopy at support NEPP5D nLight enabled control module per row/zone NYC New York City code OJB Offset junction box SCEP Sculptured end cap SLP Sloped ceiling (for 10-45°, must be specified with F2, ACG and OJB options) XXXX Integrated sensor; choose options and obtain code on page 2 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx 10CRM4 Cerra 10 I/D Indirect-Direct T8 1 Submitting Agency: Description: 10CRM4 2 32 WHR 20/80 SBL 4FT R4 120 GEB10 SCT F2/48 LP841 C210 ACG Project: Notes: Cascade Periodontics 4' LENGTH; LAMPS INCLUDED Cerra 10 I/D Type: L4 Type: ________________________ Project: ______________________ Indirect-Direct T8 Suspended 10CRM4 INTEGRATED NLIGHT MICRO SENSOR Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number. EXAMPLE: PDT1 Network Type & Sensor Power Source (choose one) Sensor Type (choose one) ADC nLight model nES ADCX Daylight Dimming Specify 0-10V dimming ballast No occupancy sensing PDT nLight model nES PDT7 ADCX Daylight Dimming and/or Occupancy Detection Specify 0-10v dimming ballast for daylight dimming Specify fixed-output ballast for occupancy detection only (daylight dimming disabled) 1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack 10’ Cat-5e cable and splitter provided 2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack No Cat-5e cable provided 3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel 10’ Cat-5e cable and splitter provided Order required remote nLight Power Pack or nPanel separately through nLight (Acuity Brands Controls) For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide *nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com. WEIGHTS & SUPPORT SPACING Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations. STANDARD SECTIONS Key: • Support or feed location 4’-0 3⁄8” 28 LBS ⁄16” standard flat end plates 4” optional sculptured end plates 1 4’-0 1⁄2” O.A. 8’-0 1⁄8” 48 LBS 8’-0 1⁄4” O.A. 12’-0” 68 LBS 12’-0 1⁄8” O.A. PLAN VIEW CONFIGURATIONS Cast corner and tenon connectors available for suspended configurations. Reference Pattern Connector Guide for additional details. PHOTOMETRICS Actual performance may differ as a result of end-user environment and application. 1-LAMP T8 91.9% efficiency 2619 delivered lumens 2-LAMP T8 91.2% efficiency 5199 delivered lumens 3-LAMP T8 90.7% efficiency 7759 delivered lumens 66.6% up / 33.4% down 62.9% up / 37.1% down 61.9% up / 38.1% down 2-LAMP T8 40/60 DISTRIBUTION 65.4% efficiency 3730 delivered lumens 2-LAMP T8 20/80 DISTRIBUTION 58.5% efficiency 3332 delivered lumens 2-LAMP T8 0/100 DISTRIBUTION 54.9% efficiency 3132 delivered lumens 36.2% up / 63.8% down 18.8% up / 81.2% down 0.9% up / 99.1% down 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx 10CRM4 Cerra 10 I/D Indirect-Direct T8 2 Submitting Agency: Description: 10CRM4 2 32 WHR 20/80 SBL 8FT R8 120 GEB10 SCT F2/48 LP841 C210 ACG Project: Notes: Cascade Periodontics 8' LENGTH; LAMPS INCLUDED Type: L8 Type: ________________________ Cerra 10 I/D Project: ______________________ Indirect-Direct T8 SCEP Option Suspended S P E C I F I C AT I O N S ________ _______ ________ ________ ________ ________ ________ ________ ________ 10CRM4 ________ ________ ________ ________ ________ _____ ________ ________ _____________________ LAMPING OPTIONS 10CRM4 - 1 10CRM4 - 2 10CRM4 - 3 2 5⁄8” 2 5⁄8” 10” 2 5⁄8” 10” 10” SPECIFICATIONS Construction Nominal 10” x 3” crescent housing is formed from one-piece cold-rolled steel. Flat end plate standard. Sculptured die-cast aluminum end cap is optional. Reflectors Die-formed highly reflective white or specular reflector. fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed. Shielding SSB—Parabolic aluminum baffle with semi specular finish. SBL—Steel straight blade baffle. PPL—Perforated steel straight blade baffle. WPB—Parabolic aluminum baffle with white finish. Luminaire Length 4’, 8’, and 12’ lengths in a single section for nominal suspension spacing of 4’, 8’, and 12’. For total luminaire length, add 1⁄16” for each flat end plate or 4” for each sculptured end cap. Using internal joiners, 4’, 8’, and 12’ sections can be joined to form longer length luminaires. Finish Fine-textured, white or aluminum polyester powder paint. Custom colors available, consult factory. Electrical Specify 120V, 277V or 347V. Pre-wired with 16AWG CATALOG NUMBER Examples: 10CRM4 2 32 WHR SSB 40FT R12 277 GEB10 DCT LP835 F1/18 C210 SCEP — 10CRM4 3 32 20/80 PPL 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110 _______ ________ Luminaire # of Lamps 10CRM4 in Cross Section _______ __________ __________ _________ _________ __________ _________ __________ Lamp Type Distribution1 Shielding Baffle Ballast Type WHR White Reflector (Standard) SPRSpecular 40/60 40% Up, 60% Down 20/80 20% Up, 80% Down 0/100 0% Up, 100% Down CLI2 Center Lamp Isolator (Blank) No diffuser OPD Standard Brightness Diffuser SSB SBL Maximum Section Length Voltage 32 Luminaire Row Length 120 277 347 GEB10 <10% THD Electronic ADEZ3 Advance Mark 10 dim DMHL3D3 Lutron Hi-Lume dim ADZT3Advance Mark 7 0-10V dim 32W T8 1 2 3 __________ # of Emergency Modules (Blank)None 1SE 1 section 2SE 2 sections XSE X sections Notes: Semi specular White steel blade X FT PPLWhite (4’ increments) perforated steel baffle WPB White Baffle (pre-finished or painted) ________________ _________ ________________ ______________ ______________ Emergency Type4 Switching Lamp Color Mounting Type SCTSingle circuit DCTDual circuit L/LP No lamp L/LPENo lamp. Wired for energy saving lamps. LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI F1/ (Blank)None ECEmergency circuit EL3 Emergency battery pack EN3Emergency battery pack w/night light circuit 1 Refer to photometric test for exact distribution 2 Available with 3-lamp cross section only 3 Not available in 347V / T-bar ceiling (universal mounting bracket) F1A/ T-bar ceiling (UMB with integrated J-box) F2/ Hard ceiling (horizontal J-box) F3/ Rigid stem Reference Lamp Chart on website or consult factory for other options. Overall Suspension 1212” 1515” 1818” 2121” 2424” XXXX” Overall suspension is measured from ceiling to bottom of luminaire. 4 EL and EC are installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified R4 R8 R12 4’ section(s) 8’ section(s) 12’ section(s) Reference Ballast Wizard on website or consult factory for other options. ______________ _________________________________ Finish Options C110Painted aluminum (low gloss) C210 White white (fine-textured low gloss) C099 Custom finish ACG BLK Adjustable cable grippers Black cord, cord manager and canopy (not available with F3) CP Chicago plenum (available with F1A only) DL Damp location label DU Dust cover ELH Emergency through wiring w/separate feed ELS Emergency through wiring w/single feed, shared neutral ELS2 Emergency through wiring w/single feed, separate neutrals GLR Fusing (fast blow) GMF Fusing (slow blow) MCS Matching feed canopy at support NEPP5D nLight enabled control module per row/zone NYC New York City code OJB Offset junction box SCEP Sculptured end cap SLP Sloped ceiling (for 10-45°, must be specified with F2, ACG and OJB options) XXXX Integrated sensor; choose options and obtain code on page 2 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx 10CRM4 Cerra 10 I/D Indirect-Direct T8 1 Submitting Agency: Description: 10CRM4 2 32 WHR 20/80 SBL 8FT R8 120 GEB10 SCT F2/48 LP841 C210 ACG Project: Notes: Cascade Periodontics 8' LENGTH; LAMPS INCLUDED Cerra 10 I/D Type: L8 Type: ________________________ Project: ______________________ Indirect-Direct T8 Suspended 10CRM4 INTEGRATED NLIGHT MICRO SENSOR Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number. EXAMPLE: PDT1 Network Type & Sensor Power Source (choose one) Sensor Type (choose one) ADC nLight model nES ADCX Daylight Dimming Specify 0-10V dimming ballast No occupancy sensing PDT nLight model nES PDT7 ADCX Daylight Dimming and/or Occupancy Detection Specify 0-10v dimming ballast for daylight dimming Specify fixed-output ballast for occupancy detection only (daylight dimming disabled) 1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack 10’ Cat-5e cable and splitter provided 2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack No Cat-5e cable provided 3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel 10’ Cat-5e cable and splitter provided Order required remote nLight Power Pack or nPanel separately through nLight (Acuity Brands Controls) For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide *nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com. WEIGHTS & SUPPORT SPACING Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations. STANDARD SECTIONS Key: • Support or feed location 4’-0 3⁄8” 28 LBS ⁄16” standard flat end plates 4” optional sculptured end plates 1 4’-0 1⁄2” O.A. 8’-0 1⁄8” 48 LBS 8’-0 1⁄4” O.A. 12’-0” 68 LBS 12’-0 1⁄8” O.A. PLAN VIEW CONFIGURATIONS Cast corner and tenon connectors available for suspended configurations. Reference Pattern Connector Guide for additional details. PHOTOMETRICS Actual performance may differ as a result of end-user environment and application. 1-LAMP T8 91.9% efficiency 2619 delivered lumens 2-LAMP T8 91.2% efficiency 5199 delivered lumens 3-LAMP T8 90.7% efficiency 7759 delivered lumens 66.6% up / 33.4% down 62.9% up / 37.1% down 61.9% up / 38.1% down 2-LAMP T8 40/60 DISTRIBUTION 65.4% efficiency 3730 delivered lumens 2-LAMP T8 20/80 DISTRIBUTION 58.5% efficiency 3332 delivered lumens 2-LAMP T8 0/100 DISTRIBUTION 54.9% efficiency 3132 delivered lumens 36.2% up / 63.8% down 18.8% up / 81.2% down 0.9% up / 99.1% down 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx 10CRM4 Cerra 10 I/D Indirect-Direct T8 2 Submitting Agency: Description: MG 24IN 3T5HO GEB10PS 120 CCV Project: Notes: Cascade Periodontics (3) F24T5HO LAMPS--BY OTHERS The Magellan Series Type: P2 Type: A softly translucent, concave dome complemented by a TM flangeless lens trim and a minimal 3/8-inch ceiling-trim Project: flange, Magellan appears to be a floating circle of light. With six standard sizes and a variety of custom trim colors, it entices the imagination and inspires creativity. Catalog Number: Magellan is suitable for lay-in or sheetrock ceilings; DO NOT TYPE HERE. Autopopulated field. fixtures must be installed before the sheetrock ceiling. Standard sizes are 12, 24, 36, 48, 60 or 72 inches in diameter. Consult factory for other sizes and for surface and pendant applications. Specification Features Technical Drawings Housing Housing and internal components fabricated from 20-gauge, cold-rolled steel. Ballast Thermally protected Class P energysaving electronic ballast. Trim Spun steel with 3/8” flange suitable for lay-in or sheetrock installation. (Note: Fixture must be installed before ceiling for sheetrock installation.) Mounting Recessed, lay-in or sheetrock. Finish Painted high reflectance white powder coat. Warranty Limited warranty, consult factory. Shielding Nominal .125”-thick white acrylic dome in nominal 12”, 24”, 36”, 48”, 60” or 72” diameters. Concave lens shape is standard, convex lens available for 12” through 48” nominal sizes. Certification cULus Listed, IBEW (Local 3) Unionmade, assembled in the USA. 65⁄8" 103⁄8", 223⁄8", 363⁄8", 463⁄8" 113⁄8", 233⁄8", 373⁄8", 47" "Y" MOUNTING HOLE LOCATIONS "X" X 6" 12" 18¾" 28" MG1 MG2 MG3 MG4 Y 131⁄16" 161⁄16" 28" 40" GALVANIZED MTG CHANNELS WITH 5⁄16" MTG HOLES FOR THRD'D ROD OR OTHER HARDWARE (BY OTHERS). Notes a. Specifications are subject to change without notice. b. Actual performance may differ as a result of end-user environment and application. c. For photometric information refer to www.marklighting.com. Lamps See lamp chart. Ordering Example: MG 24IN 3T5 GEB10PS 120 CCV SM2 Series Size MG 12IN Magellan 7¾" Number of lamps/Lamp type1 Ballast Voltage Shielding Options 12” diameter Number of lamps Lamp type1 GEB10IS3 Standard instant start 120 CCV EMPK Emergency battery pack 24IN 24” diameter 1 T5 GEB10PS Programmed rapid start 277 CVX4 Convex white acrylic CP Chicago plenum 36IN 36” diameter 2 T5HO GEB10DIM Dimming, 0 - 10v 3472 SM2 Sheet metal ceiling panel 2’x2’ 48IN 48” diameter 3 T8 DMHL3D Lutron Hi-Lume® 3D SM4 Sheet metal ceiling panel 4’x4’ 60IN 60” diameter 4 18BX ECOS Lutron Eco System® 72IN 72” diameter 6 40BX ECOSH Lutron Eco System® H-Series 8 50BX ADZT Advance Mark 7 10 26CFL Concave white acrylic 32CFL 42CFL CONFIGURATIONS Notes 1 Specify number of lamps and lamp type. See configurations table. Consult factory for other lamps. 2 Consult factory for lamp and ballast compatibility. 3 Available with T8 lamping ONLY. 4 12”, 24”, 36” and 48” nominal sizes only. marklighting.com 3 Kilmer Rd, Edison NJ 08817 T (732) 985 2600 F (732) 985 8441 SIZE NUMBER OF LAMPS LAMP TYPE 12” diameter 24” diameter 36” diameter 48” diameter 60” diameter 72” diameter 1, 2 3, 4 4, 6 6, 8 6, 8 6, 8, 10 18BX, 26CFL, 32CFL, 42CFL T5, T5HO, T8, 40BX, 50BX T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: MG 24IN 3T5HO GEB10PS 120 CCV Project: Notes: Cascade Periodontics (3) F24T5HO LAMPS--BY OTHERS Type: P2 The Magellan Series TM Photometric Information Catalog Number MG 4 6T8 Report Number 12569.0 90° 80° 800 Lamps (6) T8, rated 2950 lumens per lamp 1600 Total Efficiency 66.1% 2400 70° 60° 50° 3200 40° 0° marklighting.com 3 Kilmer Rd, Edison NJ 08817 10° T (732) 985 2600 F (732) 985 8441 20° 30° Floor 20% Ceiling 80% 50% 30% Walls 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 79 79 79 79 73 73 73 70 70 70 1 72 68 66 63 64 62 60 62 60 58 2 65 60 55 51 56 52 49 54 51 48 3 59 52 47 42 49 45 41 47 44 41 4 54 46 40 36 44 39 35 42 38 35 5 50 41 35 31 39 34 30 38 33 30 6 46 37 31 27 35 30 27 34 30 26 7 43 34 28 24 32 27 24 31 27 23 8 40 31 25 21 29 25 21 29 24 21 9 37 28 23 19 27 22 19 26 22 19 10 35 26 21 17 25 20 17 24 20 17 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: MG 24IN 3T5HO GEB10PS 120 CCV EMPK Project: Notes: Cascade Periodontics EM BATTERY; (3) F24T5HO LAMPS--BY OTHERS The Magellan Series Type: P2E Type: A softly translucent, concave dome complemented by a TM flangeless lens trim and a minimal 3/8-inch ceiling-trim Project: flange, Magellan appears to be a floating circle of light. With six standard sizes and a variety of custom trim colors, it entices the imagination and inspires creativity. Catalog Number: Magellan is suitable for lay-in or sheetrock ceilings; DO NOT TYPE HERE. Autopopulated field. fixtures must be installed before the sheetrock ceiling. Standard sizes are 12, 24, 36, 48, 60 or 72 inches in diameter. Consult factory for other sizes and for surface and pendant applications. Specification Features Technical Drawings Housing Housing and internal components fabricated from 20-gauge, cold-rolled steel. Ballast Thermally protected Class P energysaving electronic ballast. Trim Spun steel with 3/8” flange suitable for lay-in or sheetrock installation. (Note: Fixture must be installed before ceiling for sheetrock installation.) Mounting Recessed, lay-in or sheetrock. Finish Painted high reflectance white powder coat. Warranty Limited warranty, consult factory. Shielding Nominal .125”-thick white acrylic dome in nominal 12”, 24”, 36”, 48”, 60” or 72” diameters. Concave lens shape is standard, convex lens available for 12” through 48” nominal sizes. Certification cULus Listed, IBEW (Local 3) Unionmade, assembled in the USA. 65⁄8" 7¾" 103⁄8", 223⁄8", 363⁄8", 463⁄8" 113⁄8", 233⁄8", 373⁄8", 47" "Y" MOUNTING HOLE LOCATIONS "X" X 6" 12" 18¾" 28" MG1 MG2 MG3 MG4 Y 131⁄16" 161⁄16" 28" 40" GALVANIZED MTG CHANNELS WITH 5⁄16" MTG HOLES FOR THRD'D ROD OR OTHER HARDWARE (BY OTHERS). Notes a. Specifications are subject to change without notice. b. Actual performance may differ as a result of end-user environment and application. c. For photometric information refer to www.marklighting.com. Lamps See lamp chart. Ordering Example: MG 24IN 3T5 GEB10PS 120 CCV SM2 Series Size Number of lamps/Lamp type1 Ballast Voltage Shielding Options MG 12IN 12” diameter Number of lamps Lamp type1 GEB10IS3 Standard instant start 120 CCV EMPK Emergency battery pack 24IN 24” diameter 1 T5 GEB10PS Programmed rapid start 277 CVX4 Convex white acrylic CP Chicago plenum 36IN 36” diameter 2 T5HO GEB10DIM Dimming, 0 - 10v 3472 SM2 Sheet metal ceiling panel 2’x2’ 48IN 48” diameter 3 T8 DMHL3D Lutron Hi-Lume® 3D SM4 Sheet metal ceiling panel 4’x4’ 60IN 60” diameter 4 18BX ECOS Lutron Eco System® 72IN 72” diameter 6 40BX ECOSH Lutron Eco System® H-Series 8 50BX ADZT Advance Mark 7 10 26CFL Magellan Concave white acrylic 32CFL 42CFL CONFIGURATIONS Notes 1 Specify number of lamps and lamp type. See configurations table. Consult factory for other lamps. 2 Consult factory for lamp and ballast compatibility. 3 Available with T8 lamping ONLY. 4 12”, 24”, 36” and 48” nominal sizes only. marklighting.com 3 Kilmer Rd, Edison NJ 08817 T (732) 985 2600 F (732) 985 8441 SIZE NUMBER OF LAMPS LAMP TYPE 12” diameter 24” diameter 36” diameter 48” diameter 60” diameter 72” diameter 1, 2 3, 4 4, 6 6, 8 6, 8 6, 8, 10 18BX, 26CFL, 32CFL, 42CFL T5, T5HO, T8, 40BX, 50BX T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: MG 24IN 3T5HO GEB10PS 120 CCV EMPK Project: Notes: Cascade Periodontics EM BATTERY; (3) F24T5HO LAMPS--BY OTHERS Type: P2E The Magellan Series TM Photometric Information Catalog Number MG 4 6T8 Report Number 12569.0 90° 80° 800 Lamps (6) T8, rated 2950 lumens per lamp 1600 Total Efficiency 66.1% 2400 70° 60° 50° 3200 40° 0° marklighting.com 3 Kilmer Rd, Edison NJ 08817 10° T (732) 985 2600 F (732) 985 8441 20° 30° Floor 20% Ceiling 80% 50% 30% Walls 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 79 79 79 79 73 73 73 70 70 70 1 72 68 66 63 64 62 60 62 60 58 2 65 60 55 51 56 52 49 54 51 48 3 59 52 47 42 49 45 41 47 44 41 4 54 46 40 36 44 39 35 42 38 35 5 50 41 35 31 39 34 30 38 33 30 6 46 37 31 27 35 30 27 34 30 26 7 43 34 28 24 32 27 24 31 27 23 8 40 31 25 21 29 25 21 29 24 21 9 37 28 23 19 27 22 19 26 22 19 10 35 26 21 17 25 20 17 24 20 17 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: MG 36IN 6T5HO GEB10PS 120 CCV EMPK Project: Notes: Cascade Periodontics EM BATTERY; (6) F39T5HO LAMPS--BY OTHERS The Magellan Series Type: P1E Type: A softly translucent, concave dome complemented by a TM flangeless lens trim and a minimal 3/8-inch ceiling-trim Project: flange, Magellan appears to be a floating circle of light. With six standard sizes and a variety of custom trim colors, it entices the imagination and inspires creativity. Catalog Number: Magellan is suitable for lay-in or sheetrock ceilings; DO NOT TYPE HERE. Autopopulated field. fixtures must be installed before the sheetrock ceiling. Standard sizes are 12, 24, 36, 48, 60 or 72 inches in diameter. Consult factory for other sizes and for surface and pendant applications. Specification Features Technical Drawings Housing Housing and internal components fabricated from 20-gauge, cold-rolled steel. Ballast Thermally protected Class P energysaving electronic ballast. Trim Spun steel with 3/8” flange suitable for lay-in or sheetrock installation. (Note: Fixture must be installed before ceiling for sheetrock installation.) Mounting Recessed, lay-in or sheetrock. Finish Painted high reflectance white powder coat. Warranty Limited warranty, consult factory. Shielding Nominal .125”-thick white acrylic dome in nominal 12”, 24”, 36”, 48”, 60” or 72” diameters. Concave lens shape is standard, convex lens available for 12” through 48” nominal sizes. Certification cULus Listed, IBEW (Local 3) Unionmade, assembled in the USA. 65⁄8" 7¾" 103⁄8", 223⁄8", 363⁄8", 463⁄8" 113⁄8", 233⁄8", 373⁄8", 47" "Y" MOUNTING HOLE LOCATIONS "X" X 6" 12" 18¾" 28" MG1 MG2 MG3 MG4 Y 131⁄16" 161⁄16" 28" 40" GALVANIZED MTG CHANNELS WITH 5⁄16" MTG HOLES FOR THRD'D ROD OR OTHER HARDWARE (BY OTHERS). Notes a. Specifications are subject to change without notice. b. Actual performance may differ as a result of end-user environment and application. c. For photometric information refer to www.marklighting.com. Lamps See lamp chart. Ordering Example: MG 24IN 3T5 GEB10PS 120 CCV SM2 Series Size Number of lamps/Lamp type1 Ballast Voltage Shielding Options MG 12IN 12” diameter Number of lamps Lamp type1 GEB10IS3 Standard instant start 120 CCV EMPK Emergency battery pack 24IN 24” diameter 1 T5 GEB10PS Programmed rapid start 277 CVX4 Convex white acrylic CP Chicago plenum 36IN 36” diameter 2 T5HO GEB10DIM Dimming, 0 - 10v 3472 SM2 Sheet metal ceiling panel 2’x2’ 48IN 48” diameter 3 T8 DMHL3D Lutron Hi-Lume® 3D SM4 Sheet metal ceiling panel 4’x4’ 60IN 60” diameter 4 18BX ECOS Lutron Eco System® 72IN 72” diameter 6 40BX ECOSH Lutron Eco System® H-Series 8 50BX ADZT Advance Mark 7 10 26CFL Magellan Concave white acrylic 32CFL 42CFL CONFIGURATIONS Notes 1 Specify number of lamps and lamp type. See configurations table. Consult factory for other lamps. 2 Consult factory for lamp and ballast compatibility. 3 Available with T8 lamping ONLY. 4 12”, 24”, 36” and 48” nominal sizes only. marklighting.com 3 Kilmer Rd, Edison NJ 08817 T (732) 985 2600 F (732) 985 8441 SIZE NUMBER OF LAMPS LAMP TYPE 12” diameter 24” diameter 36” diameter 48” diameter 60” diameter 72” diameter 1, 2 3, 4 4, 6 6, 8 6, 8 6, 8, 10 18BX, 26CFL, 32CFL, 42CFL T5, T5HO, T8, 40BX, 50BX T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: MG 36IN 6T5HO GEB10PS 120 CCV EMPK Project: Notes: Cascade Periodontics EM BATTERY; (6) F39T5HO LAMPS--BY OTHERS Type: P1E The Magellan Series TM Photometric Information Catalog Number MG 4 6T8 Report Number 12569.0 90° 80° 800 Lamps (6) T8, rated 2950 lumens per lamp 1600 Total Efficiency 66.1% 2400 70° 60° 50° 3200 40° 0° marklighting.com 3 Kilmer Rd, Edison NJ 08817 10° T (732) 985 2600 F (732) 985 8441 20° 30° Floor 20% Ceiling 80% 50% 30% Walls 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 79 79 79 79 73 73 73 70 70 70 1 72 68 66 63 64 62 60 62 60 58 2 65 60 55 51 56 52 49 54 51 48 3 59 52 47 42 49 45 41 47 44 41 4 54 46 40 36 44 39 35 42 38 35 5 50 41 35 31 39 34 30 38 33 30 6 46 37 31 27 35 30 27 34 30 26 7 43 34 28 24 32 27 24 31 27 23 8 40 31 25 21 29 25 21 29 24 21 9 37 28 23 19 27 22 19 26 22 19 10 35 26 21 17 25 20 17 24 20 17 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: Project: Notes: Type: MG 48IN 6T5HO GEB10DIM(0-10V) 120 CCV EMPK PE Cascade Periodontics EM BATTERY; 0-10V DIMMING BALLAST; (6) F54T5HO LAMPS--BY OTHERS The Magellan Series Type: A softly translucent, concave dome complemented by a TM flangeless lens trim and a minimal 3/8-inch ceiling-trim Project: flange, Magellan appears to be a floating circle of light. With six standard sizes and a variety of custom trim colors, it entices the imagination and inspires creativity. Catalog Number: Magellan is suitable for lay-in or sheetrock ceilings; DO NOT TYPE HERE. Autopopulated field. fixtures must be installed before the sheetrock ceiling. Standard sizes are 12, 24, 36, 48, 60 or 72 inches in diameter. Consult factory for other sizes and for surface and pendant applications. Specification Features Technical Drawings Housing Housing and internal components fabricated from 20-gauge, cold-rolled steel. Ballast Thermally protected Class P energysaving electronic ballast. Trim Spun steel with 3/8” flange suitable for lay-in or sheetrock installation. (Note: Fixture must be installed before ceiling for sheetrock installation.) Mounting Recessed, lay-in or sheetrock. Finish Painted high reflectance white powder coat. Warranty Limited warranty, consult factory. Shielding Nominal .125”-thick white acrylic dome in nominal 12”, 24”, 36”, 48”, 60” or 72” diameters. Concave lens shape is standard, convex lens available for 12” through 48” nominal sizes. Certification cULus Listed, IBEW (Local 3) Unionmade, assembled in the USA. 65⁄8" 7¾" 103⁄8", 223⁄8", 363⁄8", 463⁄8" 113⁄8", 233⁄8", 373⁄8", 47" "Y" MOUNTING HOLE LOCATIONS "X" X 6" 12" 18¾" 28" MG1 MG2 MG3 MG4 Y 131⁄16" 161⁄16" 28" 40" GALVANIZED MTG CHANNELS WITH 5⁄16" MTG HOLES FOR THRD'D ROD OR OTHER HARDWARE (BY OTHERS). Notes a. Specifications are subject to change without notice. b. Actual performance may differ as a result of end-user environment and application. c. For photometric information refer to www.marklighting.com. Lamps See lamp chart. Ordering Example: MG 24IN 3T5 GEB10PS 120 CCV SM2 Series Size Number of lamps/Lamp type1 Ballast Voltage Shielding Options MG 12IN 12” diameter Number of lamps Lamp type1 GEB10IS3 Standard instant start 120 CCV EMPK Emergency battery pack 24IN 24” diameter 1 T5 GEB10PS Programmed rapid start 277 CVX4 Convex white acrylic CP Chicago plenum 36IN 36” diameter 2 T5HO GEB10DIM Dimming, 0 - 10v 3472 SM2 Sheet metal ceiling panel 2’x2’ 48IN 48” diameter 3 T8 DMHL3D Lutron Hi-Lume® 3D SM4 Sheet metal ceiling panel 4’x4’ 60IN 60” diameter 4 18BX ECOS Lutron Eco System® 72IN 72” diameter 6 40BX ECOSH Lutron Eco System® H-Series 8 50BX ADZT Advance Mark 7 10 26CFL Magellan Concave white acrylic 32CFL 42CFL CONFIGURATIONS Notes 1 Specify number of lamps and lamp type. See configurations table. Consult factory for other lamps. 2 Consult factory for lamp and ballast compatibility. 3 Available with T8 lamping ONLY. 4 12”, 24”, 36” and 48” nominal sizes only. marklighting.com 3 Kilmer Rd, Edison NJ 08817 T (732) 985 2600 F (732) 985 8441 SIZE NUMBER OF LAMPS LAMP TYPE 12” diameter 24” diameter 36” diameter 48” diameter 60” diameter 72” diameter 1, 2 3, 4 4, 6 6, 8 6, 8 6, 8, 10 18BX, 26CFL, 32CFL, 42CFL T5, T5HO, T8, 40BX, 50BX T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 T5, T5HO, T8 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: Project: Notes: Type: MG 48IN 6T5HO GEB10DIM(0-10V) 120 CCV EMPK PE Cascade Periodontics EM BATTERY; 0-10V DIMMING BALLAST; (6) F54T5HO LAMPS--BY OTHERS The Magellan Series TM Photometric Information Catalog Number MG 4 6T8 Report Number 12569.0 90° 80° 800 Lamps (6) T8, rated 2950 lumens per lamp 1600 Total Efficiency 66.1% 2400 70° 60° 50° 3200 40° 0° marklighting.com 3 Kilmer Rd, Edison NJ 08817 10° T (732) 985 2600 F (732) 985 8441 20° 30° Floor 20% Ceiling 80% 50% 30% Walls 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 79 79 79 79 73 73 73 70 70 70 1 72 68 66 63 64 62 60 62 60 58 2 65 60 55 51 56 52 49 54 51 48 3 59 52 47 42 49 45 41 47 44 41 4 54 46 40 36 44 39 35 42 38 35 5 50 41 35 31 39 34 30 38 33 30 6 46 37 31 27 35 30 27 34 30 26 7 43 34 28 24 32 27 24 31 27 23 8 40 31 25 21 29 25 21 29 24 21 9 37 28 23 19 27 22 19 26 22 19 10 35 26 21 17 25 20 17 24 20 17 ©Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance. Submitting Agency: Description: ISD BC 120/277 WH M10 Project: Notes: Cascade Periodontics WALLBOX DIMMER, WHITE Type: PE Catalog Number Notes Type Wallbox Dimmers FEATURES INTENDED USE To provide direct dimming and switching control of LED and fluorescent fixtures equipped with four-wire ( 0-10 VDC) dimming ballasts. ISD BC ATTRIBUTES Fluid slide movement allows fine adjustment of light level over the entire dimming range. Separate ON/OFF preset switch permits switching the lighting without disturbing the light level setting. An integral LED indicator turns ON when the dimmer is OFF to facilitate location in a dark room. ISD Series controls are compatible with the DSA Series wallplates and other Decora® style devices. FLUORESCENT and LED FIXTURE SLIDE DIMMER CONSTRUCTION Strap-mount device is designed to fit standard single- or multi-gang switch boxes. FINISH Standard white or ivory finish devices are supplied with a single-gang Decora style wallplate. Snap-on color change kits are available allowing field color change of the device to gray, black, brown, almond, white, or ivory. Color change kits include a matching single-gang Decora style wallplate. ELECTRICAL Uses standard single-pole or three-way wiring. No neutral connection is required. Separate low voltage connection to luminaire for 0 to 10-volt control signal. Dual rated for 120 and 277VAC ballast loads. For additional switching capacity, use in conjunction with PP20 power control station. FUNCTIONAL Integral push ON/push OFF switch allows lighting to be switched ON and OFF at the level currently set by the slider. Ballast controller can be used with standard three-way and four-way switches for applications requiring control from multiple locations. INSTALLATION Wall mounts over standard single-gang switch box. Devices can be ganged into multi-gang assemblies by breaking off the scored aluminum tabs. LISTING UL Listed. CSA Certified. WARRANTY Two -year total customer satisfaction warranty. Shown with optional DSA FP D1 WH screwless wallplate (order separately) Decora® is a registered trademark of Leviton®. Example: ISD BC 120/277 WH ORDERING INFORMATION Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. Order accessories as separate catalog number. ISD BC 120/277 Series Type Voltage ISD BCBallast controller 120/277 Dual voltage Color1 IV Ivory WHWhite Accessories NOTE: 1 ISD dimmers are supplied with standard wallplates. Order optional IV ivory or WH white screwless designer wallplates to match dimmer if desired. Order as separate item. I SD CCKIT _ _ Color change kit, specify WH (White), IV (Ivory), GY (Gray), BR (Brown), BK (Black) or AL (Almond). DSA FP D# _ _ Ivory screwless thermoplastic wallplate for ISD or Decora® compatible devices. Specify number of gangs (# =1 to 6) and color [WH (white), IV (ivory), GY (gray), BR (brown), BK (black) or AL (almond)]. Note: Consult factory for color availability in multi-gang plate configuration. Controls Sheet #: ISD-BC Submitting Agency: Description: ISD BC 120/277 WH M10 Project: Notes: Cascade Periodontics WALLBOX DIMMER, WHITE Type: PE ISD BC LED and Ballast Controller WIRING DIAGRAMS SPECIFICATIONS Single-Location Control Application CAP OFF ELECTRICAL • Input: 120/277 VAC @ 50/60Hz (switch only). DIMMER GRAY • Standard three-way operation (ON/OFF only. PURPLE RED • Maximum low voltage control loading fifty (50) ballasts. GRAY RED HOT (BLACK) BLACK BLACK LINE 120/277VAC, 60Hz • Maximum switch rating: 1200W 120VAC, 1500W 277VAC. PURPLE WHITE GREEN GROUND • Use with PP20 power control station for full 16A switching capacity. Operates three PP20 power packs per ballast controller. 0-10Vdc BALLAST TO LAMPS PRIMARY SIDE NEUTRAL (WHITE) • No derating is required for multi-gang mounting. Two-Location Control Application CLASS 2 CONDUCTORS 3-WAY SWITCH ISD BC DIMMER COMMON TERMINAL (LOAD) PURPLE GRAY HOT BLACK • Compatible with Advance Mark VII®, OSRAM Sylvania Quicktronic HeliosTM or equivilent electronic dimmable ballasts. RED GRAY BLACK PURPLE RED BLACK 0-10Vdc BALLAST LINE 120/277VAC, 60Hz WHITE PRIMARY SIDE GROUND GREEN GROUND • Compatible ballast control ranges (Subject to change without notice; contact ballast manufacturer for current specs.): ADAVANCE MARK VII COMPATIBLE DIMMING BALLAST TO LAMPS • Compatible with Lutron Hi-Lume or ECO-10 ballasts with the LEQ FDBI interface. NEUTRAL (WHITE) Three-Location Control Application COMMON TERMINAL (BLACK SCREW) 3-WAY SWITCH 4-WAY SWITCH 1 HOT (BLACK) ISD BC DIMMER 2 RED 2 RED • Consult factory for 347VAC or low voltage only switching requirements. CLASS 2 CONDUCTORS PURPLE GRAY MECHANICAL BLACK 1 PURPLE LINE VOLTAGE BLACK GREEN GROUND GREEN GROUND Advance Mark VII, RZT Series 100% to 1% continuous SYLVANIA, Helios 100% to 1% continuous GREEN GROUND WHITE ADAVANCE MARK VII COMPATIBLE DIMMING BALLAST • Captured wrap-around slide mechanism, 20mm total travel. GRAY 0-10Vdc BALLAST • Air-gap push ON/OFF preset switch. TO LAMPS PRIMARY SIDE ENVIRONMENTAL NEUTRAL (WHITE) • Operating range, 0 – 55o C, 20 – 90% relative humidity, non condensing. 1 TRAVELERS BETWEEN SWITCHES “IN” 2 TRAVELERS BETWEEN SWITCHES “OUT” NOTES: 1 Class 2 conductors as part of the same system can be run with line voltage if supplied with 600V insulation. 2 Consult factory for complete class 2 installation instructions. PP20 power packs - Two-Location Control DIMENSIONS All dimensions are inches (centimeters). PURPLE GRAY TO ADDITIONAL BALLASTS COMMON TERMINAL (BLACK SCREW) GRAY BLACK BLACK WHITE RED PP20 POWER PACK BLACK LINE VOLTAGE GREEN GROUND GRAY CAP OFF PURPLE BLACK 0-10Vdc BALLAST WHITE ISD BC DIMMER WHITE GREEN GROUND 2.68 (68.1 mm) BLUE RED 3-WAY SWITCH 3.28 (83.3 mm) BLUE HOT (BLACK) 4.15 (105.4 mm) PURPLE RED NEUTRAL (WHITE) 2.12 (53.8 mm) LINE VOLTAGE CIRCUIT #2 PP20 power pack - Single-Location Control 1.41 (35.8 mm) PURPLE GRAY PURPLE HOT (BLACK) BLACK GRAY RED LINE VOLTAGE CIRCUIT #1 RED BLUE BLUE PP20 POWER PACK WHITE BLACK BLACK ISD BC GREEN DIMMER GROUND TO ADDITIONAL BALLASTS TO ADDITIONAL BALLASTS THIS CIRCUIT WHITE RED BLUE GRAY CAP OFF PURPLE BLACK WHITE 0-10Vdc BALLAST BLUE BLACK WHITE PP20 POWER PACK BLACK GRAY CAP OFF PURPLE BLACK WHITE RED WHITE 0-10Vdc BALLAST NEUTRAL (WHITE) Synergy Lighting Controls Sheet #: ISD-BC ©2002 Acuity Brands Lighting, Inc., Rev 07/13 One Lithonia Way, Conyers, GA 30012 Phone: 800-533-2719 www.synergylightingcontrols.com 0.38 (9.7 mm) Submitting Agency: Description: FAL-8815-20-MBLK-BKCD-PL1-120E-GU24-DBAL Project: Notes: Cascade Periodontics (1) 15W GU24 DIMMING LAMP INCLUDED Type: R MINI 1­LIGHT PENDANT Base Part Number: FAL­8815 DESCRIPTION: Mini 1­Light Pendant UL LISTING: Suitable for Damp Locations LAMPING: Incandescent: (1) 40W BA­9 Torpedo Max l Optional Fluorescent: (1) 13W GU24 Self Ballast CFL Max l SIZE: 5.5" H x 5.75" Dia. (Shade)" OUTDOOR: No ADA: No PRIMARY SHADE MATERIAL: Faux Alabaster Resin Item Shown: FAL­8815­20­MBLK SHADE OPTIONS: Cylinder w/ Flat Rim (­10), Cylinder w/ Broken Rim (­12), Short Tapered Cylinder (­18), Round Flared (­20), Square Flared (­40), Cone (­50), Hourglass (­60) Metal Finishes: METAL FINISH OPTIONS: Dark Bronze (DBRZ), Brushed Nickel (NCKL), Matte Black (MBLK), Antique Brass (ABRS), Polished Chrome (CROM) Dark Bronze (DBRZ) Brushed Nickel (NCKL) Polished Chrome (CROM) Shade Shape Options: Matte Black (MBLK) Antique Brass (ABRS) CORD COLOR OPTIONS: Black or White Cord or Rigid Stem Kit OPTIONS AND NOTES: l Available with a Rigid Stem Option Kit (­RIGID), which includes a 360­degree Ball Swivel at the canopy for sloping ceilings (40­degree max slope) l Each Rigid Stem Tube Pack includes: (1) 6" Length, (2) 12" Lenghts, and (1) 18" Length for adjustable drops (48" total drop) l Additional Rigid Stem Tube sets are available for a maximum 96" drop option l Each shade includes 8 ft.of Black or White cord for adjustable drops l If illuminated for more than 2­3 continuous Submitting Agency: Description: FAL-8815-20-MBLK-BKCD-PL1-120E-GU24-DBAL Project: Notes: Cascade Periodontics (1) 15W GU24 DIMMING LAMP INCLUDED Cylinder w/ Cylinder w/ Short Round Flared Flat Rim (­10) Broken Rim Tapered (­20) (­12) Cylinder (­18) Square Flared (­40) Cone (­50) Justice Design Group, LLC. Los Angeles, California Type: R hours per day, we strongly recommend the use of screw­in CFLs or LEDs Hourglass (­ 60) Telephone: (800) 533­4799 (213) 437­0102 Fax: (800) 533­2911 (213) 437­0860 Email: sales@JDG.com Website: www.JDG.com Submitting Agency: Type: Description: SWBLED M12 Project: Notes: Cascade Periodontics LED WALL SCONCE BACKPLATE S Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — Provides maintenance-free, energy-efficient general purpose and/or accent lighting in residential and commercial indoor applications. Designed for use with a variety of Lithonia Lighting decorative sconce diffusers (see compatibility chart below) to create a look that perfectly compliments any décor. Ideal for lighting hallways or accenting seating areas. Type Decorative Indoor SWBLED CONSTRUCTION — Formed aluminum backplate. Decorative diffusers sold separately (see compatibility chart below). OPTICS — The AC-driven LED board contains 3000K high-performance LEDs that maintain 720 lumens output at 50,000 hours of life. HIGH-PERFORMANCE LED WALL SCONCE BACKPLATE ADA 4.4 COMPLIANT ELECTRICAL — 11.2 Watts. LED driver is 120V and operates at 60Hz. Actual wattage may differ by +/-10% when operating at 120V +/- 10%. Fully dimmable down to 10%. Works with most standard incandescent dimmers. See chart on back of sheet for suggested dimmers. INSTALLATION — For indoor applications only. All mounting hardware included. LISTINGS — UL and C-UL Listed to U.S. and Canadian safety requirements. Quality tested in accordance with IESNA LM-79. WARRANTY —5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. Dimensions Compatible Decorative Diffusers The SWBLED Series is designed to operate with the following decorative diffusers. See diffuser spec sheet for diffuser specifications. DLSD1, DLSD2, DLSD3, DLSD4, DLSD5, DLSD6, DLSD7, DLSD8, DLSD9, DLSD10, DLSD11, DLSD12, DLSD13, DLSD14, DLSD15, DLSD16, DLSD17 DLSD1 ORDERING INFORMATION DLSD8 DLSD14 All dimensions are inches (centimeters) Width: 5-1/2” (14) Length: 5-7/8” (14.9) Height*: 1-7/16” (3.6) * Extension from the wall. DLSD4 For shortest lead times, configure products using bolded options. Example: SWBLED SWBLED Series Options 1 SWBLED LED wall sconce backplate (Consult factory) Notes 1 Decorative diffusers must be ordered separately. DECORATIVE INDOOR & OUTDOOR SWBLED Submitting Agency: Description: SWBLED M12 Project: Notes: Cascade Periodontics LED WALL SCONCE BACKPLATE Type: S SWBLED — LED Wall Sconce Backplate PHOTOMETRICS Full photometric data report available within 2 weeks from request. Consult factory. Suggested Dimmers The MDP Series is designed to operate with most standard Triac Based (Forward Phase-Control or Leading Edge) dimmers and is not compatible with 0-10v dimming systems. The following is a list of dimmers tested with the MDP Series and does not imply any guarantee or warranty of compatibility with a particular application. Unlisted dimmers do not imply non-compatibility. Manufacturer Leviton Leviton Leviton Leviton Lutron Series Illumitech Trimatron SureSlide True Touch Skylark Part Number(s) IPI06-XXX 6602-1, 6681-X, 6683-X, 6684-X, 700-X, 705-X 6631 6606-1LM S-600, S2-LH Note: When the installation exceeds 10 fixtures on a single dimmer or distribution lengths exceed 100 feet, please confirm that the end product performs properly. This is a caused by a high degree of variability in the triac dimmers. SWBLED DECORATIVE & RESIDENTIAL: One Lithonia Way Conyers, GA 30012 Phone: 800.748.5070 Fax: 770.860.3903 www.lithonia.com © 2011-2014 Acuity Brands, Inc. All rights reserved. Rev. 08/28/14 Submitting Agency: Description: DLSD12 BN F01 Project: Notes: Cascade Periodontics DECORATIVE DIFFUSER Type: S Catalog Number Notes FEATURES & SPECIFICATIONS Type INTENDED USE — Provides maintenance-free, energy-efficient accent and/or task lighting in residential and commercial applications. The wide selection of colors and patterns complement any decor. Ideal for accent lighting in commercial applications such as hallways, stairways, foyers, offices and meeting rooms. For use with Lithonia Lighting SWBLED LED Wall Sconce Backplate. Decorative Indoor DLSD12 CONSTRUCTION — Cast aluminum bands are available in a brushed nickel or a brushed brass finish (see swatch chart and notes on back of sheet). WALL SCONCE DIFFUSER ADA 4.4 COMPLIANT A slotted polycarbonate diffuser creates a wave-like design. A variety of paper and fabric laminate finishes are available (see swatch chart and notes on back of sheet). Sanded clear acrylic top and bottom caps allow for up and down light. Exposed mounting fasteners are finished white to blend with white acrylic top and bottom panels. OPTICS — Product does not contain a light source (see SWBLED spec sheet). INSTALLATION — For indoor applications only. Wall mount vertically only. All mounting hardware included. Attaches to the wall sconce backplate using brackets provided. LISTINGS — ADA compliant. WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Specifications subject to change without notice. Dimensions All dimensions are inches (centimeters) Width: 7-1/2” (19.1) Length: 11-3/4” (29.8) Height*: 4” (10.2) * Extension from the wall. ORDERING INFORMATION Example: DLSD12 BN For shortest lead times, configure products using bolded options. DLSD12 Series Band finish 1 DLSD12 Wall sconce diffuser BN Brushed nickel BBR Brushed brass Diffuser or laminate finish/Material 2 F01 F02 F03 F04 F05 F06 F07 White linen Chocolate linen Russell square Bronze mesh Louver resin Vermicelli Stacked stone P01 P02 P03 P04 P05 P06 P07 P08 P09 P10 P11 P12 P13 White swirl Rain tree White grid Willow Tan scroll Brown nature Cascade Alma leaves Falling ash Silver rice paper Red nature Window pane Seismic white Notes 1 2 Backplate with light source is ordered separately (see spec sheet SWBLED). See reverse side for swatches. DECORATIVE INDOOR & OUTDOOR DLSD12 Submitting Agency: Description: DLSD12 BN F01 Project: Notes: Cascade Periodontics DECORATIVE DIFFUSER Type: S Wall Sconce Diffuser DIFFUSER SWATCHES Diffusers must be ordered separately from backplate with light source (SWBLED). More options may be available (consult factory). Diffusers are custom fabricated and finished. Colors and patterns may vary. Laminated materials will appear darker due to application of protective clear coating. The visualization of colors on the screen and on this document is conditional based on the characteristics of your printer, monitor and its graphic card. These swatches are intended as reference. F01 White Linen F02 Chocolate Linen F03 Russell Square F04 Bronze Mesh F05 Louver Resin F06 Vermicelli F07 Stacked Stone P01 White Swirl P02 Rain Tree P03 White Grid P04 Willow P05 Tan Scroll P06 Brown Nature P07 Cascade P09 Falling Ash P10 Silver Rice Paper P11 Red Nature P12 Window Pane P13 Seismic White P08 Alma Leaves BAND SWATCHES BN Brushed Nickel BBR Brushed Brass DLSD12 DECORATIVE & RESIDENTIAL: One Lithonia Way Conyers, GA 30012 Phone: 800.748.5070 Fax: 770.860.3903 www.lithonia.com © 2011-2012 Acuity Brands, Inc. All rights reserved. Rev. 07/09/14 Submitting Agency: Description: Z 1 17 MVOLT GEB10IS Project: Notes: Cascade Periodontics (1) F17T8 LAMP--BY OTHERS Type: S2 Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — The industry's next generation in linear direct fluorescent products. This new compact, low-profile design offers our customers unique product features which improve the overall installation process and appearance while reducing labor cost, making it the most versatile solution for commercial, retail, manufacturing, warehouse, and cove and display applications. CONSTRUCTION — Compact designed channel and cover are formed from code-gauge cold-rolled steel. Innovative T8 two-lamp back plate offers compact design and additional socket protection. Locking lamp holder tracks bolsters strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. Improved easy “snap n’ lock” end plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. Channel offers the gripper back feature which strengthens the overall construction and allows for the use of the new Z spring hanger (see back). Newly designed, patent-pending channel cover offers a secure fit design, allowing for easy access and quick attachment without pinching wires. Type One-Lamp T8 Low-Profile T5/T8 Striplight Z Two-Lamp T8 Finish: High-gloss, baked white enamel finish (white standard). Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Other channel paint finish options: black (MB), smoke gray (SMG) and galvanized (GALV). Linear Lamps 1 or 2 Lamps OPTICS — Reflector options include solid or apertured designs in both symmetric and asymmetric configurations. Consult factory for special-apertured versions. ELECTRICAL — Thermally protected, resetting, Class P, HPF, non-PCB, UL listed. Suitable for damp locations. AWN, TFN or THHN wire used throughout, rated for required temperatures. Two-Lamp T5 INSTALLATION — Patented-pending “three-point” row connector locks channel together for straighter and faster row mounting; included as standard. Ideal for surface-mount or suspended. LISTINGS — UL Listed, CUL Listed or CSA Certified to Canadian Standards. Listed for 25° C ambient temperature. WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Specifications subject to change without notice. Z Compact strip For tandem double-length unit, add prefix T. Example: TZ (see page 3 for ordering nomenclature) 1 2 Not included 17 25 32 14T5 21T5 24T5HO 28T5 39T5HO 54T5HO Voltage 17W T8 (24") 25W T8 (36") 32W T8 (48") 14W T5 (22") 21W T5 (34") 24W T5 HO (22") 28W T5 (46") 39W T5 HO (34") 54W T5 HO (46") Accessories: Order as separate catalog number. SQ_ ZSPRG HC36 ZACVH WGZ48 WGZ8SMR48 WGZ8ASR48 WGZ46 WGZ5SMR46 WGZ5ASR46 Width: 2-1/8 (5.4) Depth: 1-1/2 (3.8) Swivel-stem hanger (specify length in 2" increments) Tong and T-grid hanger (for 15/16" T-grid) Hanger chain, 36" Adjustable aircraft cable with hook 48" wireguard, white5 48" wireguard, white, for symmetric reflector5 48" wireguard, white, for asymmetric reflector5 46" wireguard, white5 46" wireguard, white, for symmetric reflector5 46" wireguard, white, for asymmetric reflector5 120 277 347 MVOLT Others available Ballast GEB10IS T8 electronic ballast, <10% THD, instant start (T8 only) GEB10RS T8 electronic ballast, <10% THD, rapid start1 GEB10PS Electronic ballast, <10% THD, programmed start BILP High-efficiency .78 bf (low) 1-1/2 (3.7) All dimensions are inches (centimeters) unless otherwise noted. Example: Z 1 32 MVOLT GEB10IS Options GLR Internal fast-blow fuse (add X for external)2 GMF Internal slow-blow fuse (add X for external)2 PLR__ Plug in wiring, specify number of branch circuits and hot wires (A-black, B-Red, C-Blue, AB or AC) EL55 Emergency battery pack (nominal 390-700 lumens); consult factory for additional battery packs2,3,4 EL65 Emergency battery pack (nominal 725-1325 lumens)2, 3, 4 TILW CSA NOM MSI MSI360 MSE360LBZ Tandem in-line wiring CSA Certified NOM Certified Aisle motion sensor2, 3 360° motion sensor2, 3 360° motion sensor; for mounting within row or at end of row2, 3, 4 Field Installable Reflectors For T8 fixtures only Z8SMR48 Symmetric reflector, 48" white5 Z8ASR48 Asymmetric reflector, 48" white5 Z8SMR36 Symmetric reflector, 36" white5 Z8ASR36 Asymmetric reflector, 36" white5 Z8SMR24 Symmetric reflector, 24" white Z8ASR24 Asymmetric reflector, 24" white For T5 fixtures only Z5SMR46 Symmetric reflector, 46" white5 Z5ASR46 Asymmetric reflector, 46" white5 Z5SMR34 Symmetric reflector, 34" white5 Z5ASR34 Asymmetric reflector, 34" white5 Z5SMR22 Symmetric reflector, 22" white Z5ASR22 Asymmetric reflector, 22" white Notes 1 For 347V. 2 Specify voltage (available 120/277V). INDUSTRIAL 2-1/8 (5.3) 1-1/2 (3.7) For shortest lead times, configure products using standard options (shown in bold.) Number Reflectors of lamps Lamp type Series 2-1/8 (5.3) T5 Length: 22-3/8 (56.8), 34-1/8 (86.7), 46 (116.8) 68-3/8(173.6) or 92 (233.6) Actual performance may differ as a result of end-user environment and application. ORDERING INFORMATION Specifications T8 Length: 24 (61.0) ,36 (91.4), 48 (121.9) 72 (182.9) or 96 (243.8) 3 4 5 Not available with CSA Certified. Available with 4' and 8' lengths only. Order two for tandem double length fixtures. Z-T8-T5 Submitting Agency: Description: Z 1 17 MVOLT GEB10IS Project: Notes: Cascade Periodontics (1) F17T8 LAMP--BY OTHERS Type: S2 Z T8 / T5 Striplight MOUNTING DATA For unit or row installation, surface or stem mounting. Unit installation — Minimum of two hangers required. Row installation — One hanger per channel plus one per row required. Review local codes when installing any product, as the minimum of 1 hanger per fixture may not satisfy your local building code. Z SPRING HANGER (ZSPRG) T8 DIMENSIONS 96 (243.7) 1-1/8 (2.7) 1-1/8 (2.7) 2-1/8 (5.4) 45-7/8 (116.5) 1-1/8 (2.7) 2-1/8 (5.4) 2-1/8 (5.4) 45-7/8 (116.5) 72 (182.7) 1-1/8 (2.7) 33-7/8 (86.0) 2-1/8 (5.4) 33-7/8 (86.0) 48 (121.9) 2-1/8 (5.4) 21-7/8 (55.5) 1-1/8 (2.7) 15-7/8 (40.3) 24 (60.9) 2-1/8 (5.4) 2-1/8 (5.4) 7/8” (2.2) Dial K.O. B .156 x .50 Slot 1-1/8 (2.7) 15-7/8 (40.3) 2-1/8 (5.4) 2-1/8 (5.3) 2-1/8 (5.3) 1-1/2 (3.7) 1-1/8 (2.7) 1-1/2 (3.7) 2-1/4 (5.6) 2-1/8 (5.4) 2-1/8 (5.5) 1-1/4 (3.3) 9-7/8 9-7/8 (25.1) (25.1) 18 (45.6) 1-1/8 (2.7) 1-1/8 (2.7) T5 DIMENSIONS A 2-1/8 (5.4) 21-7/8 (55.5) 36 (91.3) 1-1/8 (2.7) 2-1/8 (5.4) K.O. / SLOT CHART 1-1/8 (2.7) 1-1/8 (2.7) 2-1/8 (5.4) 92 (233.6) 1-1/8 (2.7) 1-1/8 (2.7) 2-1/8 (5.3) 43-7/8 (111.4) 2-1/8 (5.3) 43-7/8 (111.4) 68-3/8 (173.6) 1-1/8 (2.7) 1-1/8 (2.7) 2-1/8 (5.3) 32 (81.4) 2-1/8 (5.3) 32 (81.4) 46 (116.8) 1-1/8 (2.7) 1-1/8 (2.7) 2-1/8 (5.3) 20-7/8 (53.0) 20-7/8 (53.0) K.O. / SLOT CHART A 7/8” (2.2) Dial K.O. B .156 x .50 Slot 2-1/8 (5.3) 34-1/8 (86.7) 1-1/8 (2.7) 1-1/8 (2.7) 2-1/8 (5.3) 2-1/8 (5.3) 15 (38.0) 15 (38.0) 1-1/2 (3.7) 2-1/8 (5.3) 22-3/8 (56.8) 1-1/8 (2.7) 2-1/8 (5.3) 2 (4.9) 1-1/2 (3.7) 2 (4.9) 7/8 (2.3) 1-1/8 (2.7) 2-1/8 (5.3) 9-1/8 (23.0) PHOTOMETRICS See www.lithonia.com. INDUSTRIAL: Z-T8-T5 One Lithonia Way Conyers, GA 30012 Phone: 800-315-4963 Fax: 770-929-8789 www.lithonia.com © 2009-2014 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/05/14 Submitting Agency: Description: Z 1 17 MVOLT GEB10IS Project: Notes: Cascade Periodontics (1) F17T8 LAMP--BY OTHERS Type: S2 Z T8 / T5 Striplight REFLECTORS SMR One Lamp Z5SMR Two Lamps Z5ASR One Lamp ASR One Lamp 2-1/8 (53.4) 2-1/8 (53.4) 2 (5.1) 2-3/4 (7.0) 2-3/4 (7.0) 2-3/4 (7.0) 6-1/8 (15.5) Z8SMR One Lamp 2-1/8 (53.4 3-5/8 (9.2) Z8ASR Two Lamps 2-1/8 (53.4) 2-1/8 (53.4) 2 (5.1) 2-3/4 (7.0) 2-1/8 (53.4) 2-1/8 (53.4) 2 (5.1) 2-3/4 (7.0) 2-3/4 (7.0) 6-1/8 (15.5) 6-1/ (15.5 ASR Two Lamps SMR Two Lamps 2 (5.1) 2-3/4 (7.0) 7/8 (2.4) 3-5/8 (9.2) 6-1/8 (15.5) 3-5/8 (9.2) 7/8 (2.4) Specifications All dimensions are inches (centimeters) ORDERING INFORMATION Series/Length/Distribution Series Z5ASR Z5SMR Z8ASR Z8SMR Asymmetric reflector, T5 Symmetric reflector, T5 Asymmetric reflector, T8 Symmetric reflector, T8 Example: Z5SMR46A8 For shortest lead times, configure products using bolded options. Finish Length Z5ASR/Z5SMR only 22 Nominal 22" length 34 Nominal 34" length 46 Nominal 46" length Z8ASR/Z8SMR only 24 Nominal 24" length 36 Nominal 36" length 48 Nominal 48" length Distribution (blank) Solid A2 ASR with 2% uplight A4 ASR with 4% uplight A5 SMR with 5% uplight A8 SMR with 8% uplight P Perforated (blank) MB GALV SKGY SSR White Matte black Galvanized Smoke gray Specular finish aluminum (95% reflectance) INDUSTRIAL: Z-T8-T5 One Lithonia Way Conyers, GA 30012 Phone: 800-315-4963 Fax: 770-929-8789 www.lithonia.com © 2009-2014 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/05/14 Submitting Agency: Type: Description: LQC 1 G EL N Project: Notes: Cascade Periodontics SINGLE FACE; GREEN LETTERS; NICAD BATTERY X Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — Ideal for applications requiring general purpose emergency lighting exit sign. CONSTRUCTION — Die-cast aluminum construction – compact housing. Brushed aluminum faceplate with matte black electrostatic polymeric trim. Clear lacquer finish on brushed face inhibits fingerprints and other surface contaminants. Also available in white housing. Type Fully overlapping light seal prevents light leaks. Universal directional chevron knockouts are concealed and easily removed. Provisions for conduit entry and pendant mounting. Letters 6” high with 3/4” stroke, with 100 ft viewing distance rating, based upon UL924 standard. Die-Cast Aluminum Exit U.S. Patent No. 5,739,639. Other patents pending. OPTICS — The typical life of the exit LED lamp is 10 years. LQC ELECTRICAL — Dual-voltage input capability 120 or 277 VAC. Emergency models provided with test switch, status indicator and a battery that automatically recharges when normal power is restored. Battery option: Emergency models provided with maintenance-free, sealed nickel-cadmium battery which provides 90 minutes of emergency power. INSTALLATION — Quick-mount installation - less than 5 minutes. Universal mounting (top or end). Back mount - only available with single face. Completely concealed, easily removed mounting knockouts and hole plugs. No exposed hardware. Die-cast aluminum canopy provided. Faceplate accessory kit available for 1-face to 2-face field conversion, see accessories below. LED LAMPS LISTINGS — UL listed. Damp location listing 50°F to 104°F (10°C to 40°C). Meets UL 924, NFPA 101 (current Life Safety Code), NFPA 70-NEC and OSHA illumination standards. NEMA Premium certified. WARRANTY — 5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. Specifications 8-1/4 (20.9) Length: 11-3/4 (29.8) Depth: 2 (5.1) Height: 8-1/4 (20.9) 11-3/4 (29.8) 2 (5.1) Weight: 4.5 lbs. (2.0 kg) All dimensions are inches (centimeters) unless otherwise specified. ORDERING INFORMATION Example: LQC 1 R EL N All configurations of this product are considered standard and have short lead times. LQC Family LQC Housing color (blank) Matte black, brushed aluminum face W White Number of faces Letter color 1 Single face 2 Double Face R Red G Green Options (blank) AC only 120/277 120/277 VAC input with nickel-cadmium battery back-up EL N Accessories: Order as separate item. ELA WG1 Back-mount wireguard1 ELA WGEXT ELA WGEXE ELA B US12 Top-mount wireguard1 End-mount wireguard1 12” pendant-mount kit with black canopy. To order white canopy, replace B with W in catalog number. To order 24” or 36” lengths, replace 12 with 24 or 362 Brushed/black faceplate kit with red and green sign panel for 1-face to 2-face field conversion Brushed/black aluminum backplate for 2-face to 1-face field conversion ELA LQCFPK ELA LQCBPK ELA W LQCBPK ELA W LQCFPK EMERGENCY White backplate for 2-face to 1-face field conversion White faceplate kit with red and green sign panel for 1-face to 2-face field conversion Notes 1 2 See spec sheet ELA-WG. See spec sheet ELA-StemKits. LQC Submitting Agency: Type: Description: LQC 1 G EL N Project: Notes: Cascade Periodontics SINGLE FACE; GREEN LETTERS; NICAD BATTERY X LQC Quantum® Die-cast Aluminum LED SPECIFICATIONS MOUNTING All dimensions are inches (centimeters) unless otherwise specified. Shipping weight: 4.5 lbs. (2.0 kgs.) ELECTRICAL Top Mounting Primary Circuit Type Typical LED life1 Red LED AC only 10 years Green LED AC only 10 years Red LED emergency 10 years Green LED emergency 10 years Supply voltage 120 277 120 277 120 277 120 277 Input watts .6 .7 1.0 1.2 .6 .7 1.0 1.2 Max. amps .05 .06 .05 .06 .06 .05 .05 .06 End Mounting 5-3/4 (14.6) 4-3/4 (12.1) 8-3/4 (22.2) 8-1/4 (20.9) 2 (5.0) 11-3/4 (29.8) Back Mounting BATTERY (with EL N option) Sealed Nickel-Cadmium Shelf life2 Typical life2 Maintenance 3 years 7 - 9 years none 3 Optimum temperature4 50°–104°F (10°–40°C) 4-1/8 (10.5) 5-7/8 (14.9) 11-3/4 (29.8) Notes 1 2 Based on continuous operation. The typical life of the LED lamp is 10 years. At 77°F (25°C). 3 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 8-1/4 (20.9) KEY FEATURES ELA LQCFPK Faceplate accessory kit with red and green sign panels for 1-face to 2-face field conversion. Quick-Mount installation less than 5 minutes. The typical life of the LED lamp is 10 years. LQC EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800.334.8694 Fax: 770.981-8141 www.lithonia.com ©2007-2013 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/04/13 Submitting Agency: Type: Description: LQC 2 G EL N Project: Notes: Cascade Periodontics DOUBLE FACE; GREEN LETTERS; NICAD BATTERY OR Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — Ideal for applications requiring general purpose emergency lighting exit sign. CONSTRUCTION — Die-cast aluminum construction – compact housing. Brushed aluminum faceplate with matte black electrostatic polymeric trim. Clear lacquer finish on brushed face inhibits fingerprints and other surface contaminants. Also available in white housing. Type Fully overlapping light seal prevents light leaks. Universal directional chevron knockouts are concealed and easily removed. Provisions for conduit entry and pendant mounting. Letters 6” high with 3/4” stroke, with 100 ft viewing distance rating, based upon UL924 standard. Die-Cast Aluminum Exit U.S. Patent No. 5,739,639. Other patents pending. OPTICS — The typical life of the exit LED lamp is 10 years. LQC ELECTRICAL — Dual-voltage input capability 120 or 277 VAC. Emergency models provided with test switch, status indicator and a battery that automatically recharges when normal power is restored. Battery option: Emergency models provided with maintenance-free, sealed nickel-cadmium battery which provides 90 minutes of emergency power. INSTALLATION — Quick-mount installation - less than 5 minutes. Universal mounting (top or end). Back mount - only available with single face. Completely concealed, easily removed mounting knockouts and hole plugs. No exposed hardware. Die-cast aluminum canopy provided. Faceplate accessory kit available for 1-face to 2-face field conversion, see accessories below. LED LAMPS LISTINGS — UL listed. Damp location listing 50°F to 104°F (10°C to 40°C). Meets UL 924, NFPA 101 (current Life Safety Code), NFPA 70-NEC and OSHA illumination standards. NEMA Premium certified. WARRANTY — 5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. Specifications 8-1/4 (20.9) Length: 11-3/4 (29.8) Depth: 2 (5.1) Height: 8-1/4 (20.9) 11-3/4 (29.8) 2 (5.1) Weight: 4.5 lbs. (2.0 kg) All dimensions are inches (centimeters) unless otherwise specified. ORDERING INFORMATION Example: LQC 1 R EL N All configurations of this product are considered standard and have short lead times. LQC Family LQC Housing color (blank) Matte black, brushed aluminum face W White Number of faces Letter color 1 Single face 2 Double Face R Red G Green Options (blank) AC only 120/277 120/277 VAC input with nickel-cadmium battery back-up EL N Accessories: Order as separate item. ELA WG1 Back-mount wireguard1 ELA WGEXT ELA WGEXE ELA B US12 Top-mount wireguard1 End-mount wireguard1 12” pendant-mount kit with black canopy. To order white canopy, replace B with W in catalog number. To order 24” or 36” lengths, replace 12 with 24 or 362 Brushed/black faceplate kit with red and green sign panel for 1-face to 2-face field conversion Brushed/black aluminum backplate for 2-face to 1-face field conversion ELA LQCFPK ELA LQCBPK ELA W LQCBPK ELA W LQCFPK EMERGENCY White backplate for 2-face to 1-face field conversion White faceplate kit with red and green sign panel for 1-face to 2-face field conversion Notes 1 2 See spec sheet ELA-WG. See spec sheet ELA-StemKits. LQC Submitting Agency: Type: Description: LQC 2 G EL N Project: Notes: Cascade Periodontics DOUBLE FACE; GREEN LETTERS; NICAD BATTERY OR LQC Quantum® Die-cast Aluminum LED SPECIFICATIONS MOUNTING All dimensions are inches (centimeters) unless otherwise specified. Shipping weight: 4.5 lbs. (2.0 kgs.) ELECTRICAL Top Mounting Primary Circuit Type Typical LED life1 Red LED AC only 10 years Green LED AC only 10 years Red LED emergency 10 years Green LED emergency 10 years Supply voltage 120 277 120 277 120 277 120 277 Input watts .6 .7 1.0 1.2 .6 .7 1.0 1.2 Max. amps .05 .06 .05 .06 .06 .05 .05 .06 End Mounting 5-3/4 (14.6) 4-3/4 (12.1) 8-3/4 (22.2) 8-1/4 (20.9) 2 (5.0) 11-3/4 (29.8) Back Mounting BATTERY (with EL N option) Sealed Nickel-Cadmium Shelf life2 Typical life2 Maintenance 3 years 7 - 9 years none 3 Optimum temperature4 50°–104°F (10°–40°C) 4-1/8 (10.5) 5-7/8 (14.9) 11-3/4 (29.8) Notes 1 2 Based on continuous operation. The typical life of the LED lamp is 10 years. At 77°F (25°C). 3 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 8-1/4 (20.9) KEY FEATURES ELA LQCFPK Faceplate accessory kit with red and green sign panels for 1-face to 2-face field conversion. Quick-Mount installation less than 5 minutes. The typical life of the LED lamp is 10 years. LQC EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800.334.8694 Fax: 770.981-8141 www.lithonia.com ©2007-2013 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/04/13 D ESCRIPTION The Halo RL560 is a complete LED Baffle-Trim Module for 5” and 6” aperture recessed downlights; suitable for new construction, remodel and retrofit installation. The RL560 is cULus Listed for use with Halo and All-Pro, and is UL Classified for use with other compatible 5” and 6” housings. The RL560 with integral LED driver offers 120 volt dimming capability. The RL560 lens provides uniform illumination and wet location listing. The die-cast construction makes any housing AIR-TITE for added HVAC savings and code compliance. HALO Catalog # Project Type RL560WH6830 T CASCADE PERIODONTI Date Comments Prepared by S PECIFICATION FEATU RES MECHANICAL Module - Trim t .PEVMFDPOTUSVDUJPOJODMVEFT LED, heat sink, reflector, lens, baffle and trim ring t %VSBCMFEJFDBTUBMVNJOVN construction t 3FHSFTTFECBGGMF t )FBUTJOLEFTJHOFEUPDPOEVDU heat away from the LED keeping the junction temperatures below specified maximums, even when installed in insulated ceiling environments t )BMPNBUUFXIJUFQBJOUGJOJTI t )BMPTBUJOOJDLFMQMBUFEGJOJTI Lens t 3FHSFTTFEMFOT t *NQBDUSFTJTUBOUQPMZDBSCPOBUF t $POWFYGPSNGPSMBNQMJLF appearance t )JHIMVNFOUSBOTNJTTJPO t%JGGVTJOHGPSFWFOJMMVNJOBUJPO MOUNTING Torsion Spring Brackets t 1SFJOTUBMMFEQSFDJTJPOGPSNFE torsion spring brackets secure torsion springs and adjust to fit 5” or 6” compatible housings 5” & 6” Friction Blade Kit t 1SFDJTJPOGPSNFEGSJDUJPO blades included t 1SPWJEFBMUFSOBUJWFUP torsion springs for retrofit in 5” and 6” housings without torsion spring mounting tabs. t 'SJDUJPOCMBEFEFTJHOBMMPXT the RL560 to be installed in any position within the housing aperture (360 degrees). t 3FQMBDFNFOU,JUNPEFM RL56CLIP Housing Compatibility See Housing Compatibility LED t $PMPS5FNQFSBUVSF$$5 † 0QUJPOT,,BOE , t $PMPS3FOEFSJOH*OEFY$3* † Options: 83 and 92 t -VNFONBJOUFOBODF L70 at 50,000 hours projected in accordance with IES TM-21 t-&%JTBDIJQPOCPBSEEFTJHO consisting of a multiple LED package with proximity phosphor coating to create one virtual white light source for a productive “cone of light” ELECTRICAL Power Connections t -&%DPOOFDUPSJTBOPOTDSFX base luminaire disconnect offering easy installation with the matching Halo 5” H550 Series and 6” H750 Series housings. t -&%$POOFDUPSNFFUT California Title-24 high-efficacy luminaire requirement for a non-screw base socket, and where required to qualify as a high-efficacy luminaire. t 5IFJODMVEFE&NFEJVN screw-base Edison adapter provides easy retrofit of incandescent housings (see Housing Compatibility). Ground Connection t 4FQBSBUFHSPVOEJOHDBCMF included on the module for attachment to the housing during installation. LED Driver t %JNNBCMFESJWFSJTB7PMU high efficiency, electronic power supply providing DC power to the LED. t %SJWFSNFFUT'$$&.*3'* Consumer Level limits for use in residential and commercial installations. t %SJWFSGFBUVSFTIJHIQPXFS factor, low THD, and has integral thermal protection in the event of over temperature or internal failure. Dimming t 5IF)BMP3--&%NPEVMF is designed for dimming capability to 10% in normal operation with standard 120V electronic low voltage, LED-Rated, and many incandescent dimmers. The RL560 has dimming capability to 5% with select dimmers with low end trim adjustment. (Consult dimmer manufacturer for dimmer compatibility and details. Note, some dimmers require a neutral in the wallbox. Warranty Cooper Lighting provides a five year limited warranty on RL56 LED. RL560WH† White Compliance Labels t 6-D6--JTUFE-VNJOBJSF (with listed Halo and All-Pro housings) t 6-$MBTTJGJFEXJUIPUIFS housings - see Housing Compatibility) t 6-D6--JTUFEGPS%BNQ Location t 6-D6--JTUFEGPS8FU-PDBUJPO – Shower Applications t *1*OHSFTT1SPUFDUJPOSBUFE t .BZCFJOTUBMMFEJOIPVTJOHT in direct contact with air permeable insulation** and combustible material RL560SN† Satin Nickel 80CRI 2700K, 3000K and 3500K Qualification t &/&3(:45"3® qualified residential and commercial* t $BOCFVTFEGPS4UBUFPG California Title 24 high efficacy luminaire compliance* t $BOCFVTFEGPS*OUFSOBUJPOBM Energy Conservation Code (IECC) high efficacy luminaire compliance 90CRI (white only) 3000K and 3500K 5-Inch / 6-Inch LED Recessed Retrofit Module-Trim IC and AIR-TITE™ Certified under ASTM-E283 BOEMJTUFE6-D6-XJUI compatible housings, may be used to meet insulated ceiling** and restricted air-flow requirements such as: t 8BTIJOHUPO4UBUF&OFSHZ Code t *OUFSOBUJPOBM&OFSHZ Conservation Code (IECC) t /FX:PSL4UBUF&OFSHZ Conservation Construction $PEF/:&$$$ t 4UBUFPG$BMJGPSOJB5JUMF “Recessed Luminaires in Insulated Ceilings.” FOR USE IN INSULATED CEILING AND NON- INSULATED CEILING RATED HOUSINGS HIGH EFFICACY LED WITH INTEGRAL DRIVER - DIMMABLE 2700K nominal 2725 2700K 3000K 3500K 4100K 5000K 3000K 6500K nominal 3045 2700K 3000K 3500K 4100K 5000K 3500K 6500K nominal 3465 *Qualified and compliant. Refer to ENERGY STAR ® 2700K 3000K 3500K 4100K 5000K 6500K Qualified Products List and CEC (T24) Appliance Database for listings. www.cooperlighting.com ** Not for use with housings in direct contact with spray foam insulation. † See ordering information table for available models. ADV131344 August 29, 2013 9:30 AM 7" [178mm] 7 1/2" [191mm] 1/2" [13mm] 6-1/2" [165mm] 10 1/2" [267mm] H7ICATNB DESCRIPTION The H7 recessed housings are the standard in the industry for both commercial and residential applications. The wide variety of trims available allows a number of different lighting effects to be created with one basic housing. The H7ICATNB is designed for installations where the housing will be in direct contact with insulation. Additionally, the H7ICATNB housing meets restricted air flow requirements. The H7ICATNB is designed to save installation time. It is designed without a socket plate for use with socket supporting trims only. With these trims there is no need to spend time removing the socket from the socket plate and the socket plate from the housing. be removed from plaster frame to provide access to the junction box. Slide-N-Side™ Junction box • UL Listed for through branch circuit wiring (maximum 8 No.12 ga., 90°C conductors). • Seven 1/2" trade size conduit knockouts . • Slide-N-Side™ wire traps allow non-metallic sheathed cable to be installed without tools and without removing knockouts. Accepts a wide range of nonmetallic sheathed cable. • Allows wiring connections to be made outside the junction box • Simply insert the cable directly into the trap after connections are made. • Accommodates the following standard non-metallic sheathed cable sizes: (US) #14/2, #14/3, #12/2, #12/3 (Canada) #14/2, #14/3, #12/2 • Automatic levelling flange aligns the housing and lets you hold the housing in place with one hand while driving nails. • Housing can be positioned at any point within 24" joist span • Pass-N-Thru™ feature allows bar hangers to be shortened without removing from plaster frame. • Integral T-bar clip snaps onto Tbars - no additional clips required. . Socket Porcelain socket with nickel plated brass screw shell, snaps into trim for consistent lamp positioning. Thermal Protector Self resetting thermal protector deactivates fixture if overheating occurs due to improper lamping. Labels Housing • UL/cUL Listed Aluminum construction for greater heat dissipation. • UL/cUL Listed for Feed Through • UL/cUL Listed for Direct Contact Socket Plate with Insulation and combustible GOT NAIL! Pass-N-Thru™ Rigid socket plate adjusts and material Bar Hangers. locks without tools for various Meets following requirements: lamp sizes. • Pre-installed nail easily installs • State of California Title 24 Low in regular lumber, engineered Plaster Frame Efficacy Luminaire IC and AT lumber and laminated beams. Housing adjusts in plaster frame Requirement • Score lines allow "tooless" to accommodate up to 1” ceiling • Washington State Energy shortening for 12" joists. thickness. Plaster frame features Code • Bar hangers can be repositioned include: • International Energy 90° on plaster frame • Regressed locking screw for Conservation Code (IECC) securing hanger bars • Safety and guidance system • New York State Energy • Cutouts for easily crimping prevents snagging, ensures Conservation Construction hanger bars in position smooth straight nail penetration Code • Halo name embossed on plaster and allows bar hangers to be • Certified Under ASTM-E283 frame Galvanized steel easily removed if necessary. construction. The housing can 6" Aperture IC Insulated Ceiling No Socket Bracket 1 2 0 V L i n e Vo l t a g e RECESSED DOWNLIGHTING Incandescent DIMENSIONS 6" HALO® RECESSED DOWNLIGHTING • For use with socket supporting trims • Eliminates time and labor cost of adjusting lamp position or removing socket and socket bracket during installation • Thermally Protected IC AIR-TITE™ Housing • Housing may be covered with insulation • For use with 120V Incandescent lamps GA-ATH7-6PK 6-pack H7ICAT Air-Tite™ gaskets A housing gasket is the final step in completing an air-tight, codecompliant installation. Halo makes this final step simple by including an AirTite™ gasket in each housing to complete the final installation of the can opening. Should the gaskets be lost or discarded during the rough-in phase of installation these replacement kits are available. COOPER LIGHTING 131 RL56 Series LIGHTING FACTS RL560WH6827 RL560WH6830 RL560WH6835 ,4PVSDF ,4PVSDF ,4PVSDF RL560WH6930 RL560WH6935 ,4PVSDF ,4PVSDF ENERGY DATA RL560 Series Energy Data: (Values at non-dimming line voltage) Minimum Starting Temp: -30°C (-22°F) EMI/RFI: FCC Title 47 CFR, Part 18, Class B (Consumer) Sound Rating: Class A standards Input Voltage: 120V Power Factor: >0.90 Input Frequency: 60Hz THD: <20% Input Power: 10.5W (RL560WH6827, RL560SN6827, RL560WH6930, RL560WH6935) Input Power: 9.4W (RL560WH6830, RL560SN6830, RL560WH6835) Input Current: .15A Maximum IC (Insulated Ceiling) Ambient Continuous Operating Temperature: 25°C (77°F) Maximum Non-IC Ambient Continuous Operating Temperature 40°C (104°F) RL560SN6827 RL560SN6830 ,4PVSDF ,4PVSDF DIMENSIONS 3.15” [80mm] Ø 7.25” [184mm] www.cooperlighting.com RL56 Series ORDERING INFORM ATI O N SAMPLE NUMBER: RL560WH6827 Complete unit includes a RL560 Baffle-Trim LED Module and a 5” and 6” compatible housing, ordered separately. RL56 Series Accessory (order separately) 80 CRI RL560WH6827= 5”/6” Retrofit Baffle - Trim LED Module, 83CRI, 2700K, Matte White RL560SN6827= 5”/6” Retrofit Baffle - Trim LED Module, 83CRI, 2700K, Satin Nickel RL560WH6830= 5”/6” Retrofit Baffle - Trim LED Module, 83CRI, 3000K, Matte White RL560SN6830= 5”/6” Retrofit Baffle - Trim LED Module, 83CRI, 3000K, Satin Nickel RL560WH6835= 5”/6” Retrofit Baffle - Trim LED Module, 83CRI, 3500K, Matte White RL56CLIP=Replacement kit of 5” and 6” Friction Clips for retrofitting into an existing housing without torsion spring receiving brackets. (One set of clips included with the unit.) OT400P=Oversize Flat White Metal Trim Ring 6” I.D. x 9-1/4” O.D. (ring slips behind RL560 ring, in stepped configuration) OT403P=Oversize White Plastic Trim Ring 6” I.D. x 8” O.D. (ring slips behind RL560 ring, in stepped configuration) TRM690WH=Oversize Matte White Metal Trim Ring. Designed for RL560 ring to inset into oversize ring for an even (non-stepped) trim surface HE26LED=Replacement screw base adapter (one included with unit) 90 CRI RL560WH6930= 5”/6” Retrofit Baffle - Trim LED Module, 92CRI, 3000K, Matte White RL560WH6935= 5”/6” Retrofit Baffle - Trim LED Module, 92CRI, 3500K, Matte White HOUSINGS - Halo and All-Pro UL Listed Compatibility Compatible Halo LED Housings with LED luminaire connector (high-efficacy compliant) Recessed Can Size Catalog Number 5" HALO 6" Description H550ICAT 5" LED, Insulated Ceiling, AIR-TITE, New Construction Housing H550RICAT 5" LED, Insulated Ceiling, AIR-TITE, Remodel Housing H750ICAT 6" LED, Insulated Ceiling, AIR-TITE, New Construction Housing H750RICAT 6" LED, Insulated Ceiling, AIR-TITE, Remodel Housing H750T 6" LED, Non-IC, AIR-TITE, New Construction Housing H750RINTD010 6" LED, Non-IC, AIR-TITE, Remodel International Housing, 0-10V DC Dimming H750TCP 6" LED, Non-IC, New Construction/Remodel Chicago Plenum Housing H2750ICAT 6” LED, Shallow, Insulated Ceiling, AIR-TITE, New Construction Housing Compatible Halo Incandescent E26 Screwbase Housings 5" HALO 6" www.cooperlighting.com H5ICAT 5” Insulated Ceiling, AIR-TITE New Construction Housing H5RICAT 5” Insulated Ceiling, AIR-TITE Remodel Housing H5T 5” Non-IC, New Construction Housing H5RT 5” Non-IC, Remodel Housing H5TM 5” Non-IC, New Construction Housing (metric version - Canada) H25ICAT 5” Shallow, Insulated Ceiling, AIR-TITE New Construction H7ICAT 6” Insulated Ceiling, AIR-TITE New Construction Housing H7RICAT 6” Insulated Ceiling, AIR-TITE Remodel Housing H7ICT 6” Insulated Ceiling, New Construction Housing H7RICT 6” Insulated Ceiling, Remodel Housing H7ICATNB 6” Insulated Ceiling, AIR-TITE New Construction Housing, No Socket Bracket H7ICTNB 6” Insulated Ceiling, New Construction Housing, No Socket Bracket H7T 6” Non-IC, New Construction Housing H7RT 6” Non-IC, Remodel Housing H7TNB 6” Non-IC, New Construction Housing, No Socket Bracket H7TCP 6” Non-IC, Chicago Plenum, New Construction/Remodel Housing H7UICT 6” Insulated Ceiling, Universal New Construction Housing H7UICAT 6” Insulated Ceiling, Universal, AIR-TITE, New Construction Housing H27ICAT 6” Shallow, Insulated Ceiling, AIR-TITE New Construction Housing H27RICAT 6” Shallow, Insulated Ceiling, AIR-TITE Remodel Housing H27ICT 6” Shallow, Insulated Ceiling, New Construction Housing H27RICT 6” Shallow, Insulated Ceiling, Remodel Housing H27T 6” Shallow, Non-IC, New Construction Housing H27RT 6” Shallow, Non-IC, Remodel Housing Submitting Agency: Type: Description: WSX XX Project: Notes: Cascade Periodontics WALL SWITCH SENSOR Catalog Number Notes PRODUCT OVERVIEW The WSX Family of wall switch occupancy sensors provides simple and cost effective solutions for commercial and residential lighting control applications. All WSX Family sensors have a stylish low profile appearance, soft-click buttons, and provide small motion detection up to 20 ft (6.10 m), making them perfect for private offices, private rest rooms, closets, copy rooms, or any other small enclosed space. Additionally, all WSX Family sensors have a patent-pending wiring method that enables them to function either with or without a neutral connection. WSX units come pre-configured for wiring without a neutral, however if connection to neutral is required by code, contractors can convert the unit in seconds (see page 3). Type WSX FAMILY WALL SWITCH SENSOR w/ CONVERTIBLE NEUTRAL / NO NEUTRAL WIRING, PASSIVE INFRARED (PIR) or DUAL TECH (PDT) All WSX Family sensors utilize 100% digital Passive Infrared (PIR) detection. Dual Technology (PDT option) versions add Microphonics detection and are recommended for offices and rooms with obstructions. Additional versions include units with dual relays - perfect for bi-level applications, and units with an integrated nightlight - perfect for restrooms and residential applications. SENSOR OPERATION — WSX sensors detect changes in the Passive Infrared (PIR) energy given off by occupants as they move within the field-of-view. In an Auto-On sensor, once occupancy is detected, an internal relay switches on the connected lighting load. In a Vacancy (Manual On) sensor, the unit’s push button must first be pressed to initiate the lights on. In a dual relay sensor, once occupancy is detected the unit will automatically close Pole 1’s relay while still requiring Pole 2’s pushbutton be pressed in order to close Pole 2’s relay. All modes are user adjustable (see On Modes section). After the lights are turned on, an internal timer keeps them on during brief periods of inactivity. Once the time delay has expired, lights are turned off automatically. The default time delay is 10 minutes - chosen in order to maximize energy savings while preventing false-offs. This timer is programmable from 30 seconds to 30 minutes, and is reset every time occupancy is re-detected. Patented LampMaximzer technology is also present in these sensors, providing an additional minimum on time (disabled by default) to be utilized if desired. WSX sensors with Passive Dual Technology (PDT option) first see motion using Passive Infrared (PIR) and then engage Microphonics to listen for sounds that also indicate continued occupancy. This patented technology dynamically adapts a sensor to its environment by filtering out constant background noise and detecting only noises typical of human activity. WSX WSX PDT WSX NL WSX PDT NL WSX 2P WSX PDT 2P KEY OPTIONS NIGHT LIGHT (NL) Ideal for bathrooms (hotel / hospital) or residential applications • Ultra low power White LED night light (24/7 operation) • Capable of powering over Ground (no Neutral required) • Manual On / Auto Off operation of lights (default) • Available with Single or Dual Relays DUAL RELAY (2P) Ideal for bi-level switched rooms or restroom with light & fan • Includes two isolated relays, Pole 1 defaulted to Auto On, Pole 2 to Vacancy • Enables separate time delay per pole - programmed via each pole’s push-button • UL listed to switch different loads per pole - e.g. 277 VAC lights on Pole 1 and 120 VAC fan on Pole 2 LOW TEMPERATURE / HIGH HUMIDITY (LT) Required for cold / humid areas • Device electronics are coated for corrosion resistance • Operates down to -40º F/C (-4º F / 20º C for PDT) FEATURES • 100% digital PIR detection - excellent RF immunity • Ruggedized assembly, vandal resistant lens standard • Small motion detection to 20 ft • Dual Technology (PDT) utilizes PIR / Microphonics detection (patented) • 100% passive detection, no potential for interference with other building systems • Self-grounding mounting strap • White LED status indicator • Device accommodates powering over ground or neutral connection (patent pending) • Ultra low current leakage (<0.5 mA) when connected via ground • Fully meets NEC 2011 Section 404.2C neutral requirements - no current leakage to ground when connected to neutral • Line power and load wires are interchangeable impossible to wire backwards (patented) • Compatible w/ LEDs, Electronic & Magnetic Ballasts, CFLs, & Incandescents • Photocell standard (disabled by default) - prevents lights from initially turning on if sufficient daylight is present, but does not turn lights off. Photocell not available in Night Light or Vacancy only versions. • Integrated LampMaximizer minimum on time (patented) provides increased fluorescent lamp life - disabled by default • Push-button programmable without removing cover plate - adjustable time delays & operating modes • Non-volatile settings memory • Includes wall plate (screwless sold separate) Sensor Switch 900 Northrop Road, Wallingford, CT 06492 Phone: 1.800.PASSIVE sensorswitch.com ©2013 Acuity Brands Lighting, Inc. All rights reserved 09/05/13 1 of 4 Submitting Agency: Type: Description: WSX XX Project: Notes: Cascade Periodontics WALL SWITCH SENSOR WSX Family OPERATIONAL SETTINGS __________________________________________________________________________________________________ Predictive Mode (setting 3) determines if a user has left the room after the lights are switched off. It does this by monitoring the space for a period after the button is pressed (Predictive Grace Time), following a delay to allow exiting the room (Predictive Exit Time). If occupancy is detected the device will disable Auto-On & hold the lights off until manually switched. If no occupancy is detected the sensor instantly reverts to auto-on mode. * NOTE: ( ) Indicates factory default (unless otherwise marked) 2 = Occupancy Time Delay Time sensor keeps lights on after last occupancy detection. 1 30 sec 4 7.5 min 7 15.0 min 13 30.0 min 2 2.5 min 5 10.0 min* 8 17.5 min 3 5.0 min 6 12.5 min 9 20.0 min For additional time settings, contact technical support at 1.800.PASSIVE If Predictive Mode with Expiration (setting 4) is enabled, once the sensor has disabled Auto-On it will continue to monitor the space. When no occupancy is detected for a duration equal to the occupancy time delay, the sensor will revert to Auto-On mode. 1 Override Off ** 2 Switch Disable 3 Predictive Mode 4 Predictive Mode with Expiration* 3 = On Mode Automatic On turns lights on when occupancy is detected. Manual On requires a button press to turn the lights on. Reduced Turn-On directs the sensor to only turn on when a large motion, such as a person entering a room, is detected. Weaker signals, such as reflections from glass, are ignored. Once lights are on, the sensor returns to maximum sensitivity. 1 Automatic On 2 Manual On * Default for WSX (PDT) units & Pole 1 of WSX (PDT) 2P units ** Default for units with -SA, -VA, or -NL options, Pole 2 of WSX (PDT) 2P units, and both poles of 2P units with -2SA, -2VA, or -NL options 3 Reduced Turn-On Settings 1 & 3 not available on -VA (Vacancy only) sensors. Notes on Default Settings • WSX (PDT) Series default: Automatic On • Default for units with -SA, -VA, or -NL option: Manual On • WSX (PDT) 2P Series default: Pole 1 Auto On, Pole 2 Manual • Default for 2P units with -2SA, -2VA, or NL options: Both poles Manual On 5 = Photocell Set-Point The ambient light level at which the sensor prevents the lights from initially turning on. Once on, the lights will remain on until the occupancy time delay expires and turns them off. 1 Disabled* 5 2 fc 9 32 fc 2 Auto Setpoint 6 4 fc 10 64 fc 3 0.5 fc 7 8 fc 4 1 fc 8 16 fc Note: Sensor changes to Auto On mode if photocell is enabled. Photocell not present in -NL versions. 4 = Switch Modes These modes dictate switch functionality. Pressing the button in Override Off mode (setting 1) turns off and keeps lights off until pressed again. Indicates behavior of device’s LED. 1 Occupancy Indication* 3 Disabled 2 Relay Indication 4 Override On*** *Standard Factory Default Returns all functions to original settings. 1 Maintain Current* 2 Restore Defaults 10 = Minimum On Time Required initial time for lamps to be on after each switch on, regardless of occupancy status. Once met, lights resume following occupancy time delay. 1 0 min (disabled)* 3 30 min 5 60 min 2 15 min 4 45 min 11 = Manual On Grace Period Time period after lights automatically turn off that they can be reactivated by motion. (Manual On (Semi-Auto) mode only) 1 0 sec 2 Unused 3 15 sec* 12 = Dual Technology (MicrophonicsTM) Relative responsiveness of Microphonics detection. 1 Normal* 3 Medium 5 Phase Off 2Off 4 Low (15-10-5 min) 13 = Microphone Grace Period Time period after lights are automatically turned off that they can be voice reactivated. 1 0 sec 3 20 sec 5 40 sec 7 60 sec 2 10 sec* 4 30 sec 6 50 sec 15 = Predictive Exit Time Time period after manually switching lights off for occupant to leave the space. 1 5 sec 3 7 sec 5 9 sec 7 15 sec 9 30 sec 2 6 sec 4 8 sec 6 10 sec* 8 20 sec 16 = Predictive Grace Time 7 = LED Operation Disabling the Switch (setting 2) prevents the button from turning the lights on. (continued next column) 9 = Restore Factory Defaults *** Factory Default for -NL version Time period after Predictive Exit Time that sensor rescans the room for remaining occupants. 1 0 sec 3 10 sec 5 30 sec* 7 50 sec 2 5 sec 4 20 sec 6 40 sec 8 60 sec PROGRAMMING INSTRUCTIONS _______________________________________________________________________________________ Operational settings can be changed via the push-button sequence outlined below (note the example used is for changing occupancy time delay). Programming for 2P units done with each pole’s corresponding push-button. 1. 1. 2. Predictive Exit Time Microphone Grace Period Dual Technology 15x While LED flashes back new setting 10x... e.g., 4 flashes indicates new 7.5 min time delay setting 3. 2x 3x 4x 5x PRESS BUTTON 11x 10x Minimum On Time 6. 9x 4. 3. On Mode 12x Manual On Grace Period 5. 16x e.g., press 2x for Occupancy Time Delay Occupancy Time Delay 13x (MicrophonicsTM) 5. Predictive Grace Time 7x Restore Factory Defaults 4. 30 min 20 min Photocell Set-Pt 17.5 min 2.5 min 1x 2x 8x 7x e.g., 5 flashes is default 10 min time delay LED Operation 13x 9x While LED flashes back current setting 10x... Switch Mode 30 sec 15.0 min 3x PRESS BUTTON 6x 12.5 min 5x 5.0 min 4x 7.5 min 10 min e.g., press 4x to change to 7.5 min 6. Predictive Exit Time Microphone Grace Period Dual Technology Predictive Grace Time 15x 16x 2x On Mode 3x 13x 12x Manual On Grace Period Switch Mode 4x 5x PRESS BUTTON TM (Microphonics ) 11x 10x Minimum On Time 7. Occupancy Time Delay 9x 7x Restore Factory Defaults Photocell Set-Pt 7. LED FLASHES CONFIRMATION TWICE PROGRAMMING COMPLETE LED Operation e.g., press 2x to save and exit Sensor Switch 900 Northrop Road, Wallingford, CT 06492 Phone: 1.800.PASSIVE sensorswitch.com ©2013 Acuity Brands Lighting, Inc. All rights reserved 09/05/13 2 of 4 Submitting Agency: Type: Description: WSX XX Project: Notes: Cascade Periodontics WALL SWITCH SENSOR WSX Family COVERAGE PATTERN TOP VIEW • Small motion (e.g., hand movements) detection up to 20 ft (6.10 m), ~625 ft2 • Large motion (e.g., walking) detection greater than 36 ft (10.97 m), ~2025 ft2 • Wall-to-Wall coverage • Passive Dual Technology (Microphonics) provides overlapping detection of human activity over the complete PIR coverage area. Advanced filtering is SIDE VIEW utilized to prevent non-occupant noises from 1.2 m 4 ft keeping the lights on. 0m 0 ft 3 6 9 12 9 18 27 36 Small motion detection to ~20 ft 20 6 10 3 Small motion detection to ~20 ft 012 ft 0 m 9 36 30 6 3 0m 3 6 9 12 20 10 0 ft 10 20 30 36 Small motion ~40 ft coverage Large motion detection to >36 ft CONVERSION FROM GROUND ONLY (NO NEUTRAL) TO NEUTRAL WIRING This product is pre-configured for wiring without a neutral, however if connection to neutral is required by code, contractors can quickly and easily convert the unit in seconds. REMOVE METAL LINK IF CONNEC TING TO NEUTRAL Step 2: Loosen Screws and Remove Metal Link Step 1: Remove Yellow Label Step 3: Connect Neutral to Silver Screw and Ground to Green Screw WIRING TO GROUND (NO NEUTRAL) WIRING TO NEUTRAL SINGLE RELAY SINGLE RELAY WIRE COLOR KEY GND 120/277 VAC WIRING BLACK* - Line 1 Input BLACK* - Load 1 Output BLUE* - Line 2 Input BLUE* - Load 2 Output N H REMOVE METAL LINK IF CONNE CTING TO NEUTRAL BLK LOAD 1 BLK GND H N H N *BLACK wires can be reversed BLK LOAD 1 BLK DUAL RELAY N N H REMOVE METAL LINK IF CONNE CTING TO NEUTRAL LOAD 2 BLU BLU N H GND *BLUE wires can be reversed 347 VAC WIRING (-347 Option) Red wires replace Black wires. DUAL RELAY N } } N H GND BLK BLK LOAD 1 LOAD 2 BLU BLU BLK BLK LOAD 1 Notes: - Unit will draw power from either line connection. - When switching 277 VAC or 347 VAC on both relays, the line inputs must be of the same phase. Sensor Switch 900 Northrop Road, Wallingford, CT 06492 Phone: 1.800.PASSIVE sensorswitch.com ©2013 Acuity Brands Lighting, Inc. All rights reserved 09/05/13 3 of 4 Submitting Agency: Type: Description: WSX XX Project: Notes: Cascade Periodontics WALL SWITCH SENSOR WSX Family SPECIFICATIONS PHYSICAL SPECS SIZE: 2.74”H x 1.68”W x 1.63”D (6.96 cm x 4.27 cm x 4.14 cm) (not including ground strap) WEIGHT: 5 oz MOUNTING: Single Gang Switch Box MOUNTING HEIGHT: 30-48 in (76.2-121.9 cm) SILICONE FREE ROHS COMPLIANT ELECTRICAL SPECS MAXIMUM LOAD / POLE (RELAY) 800 W @ 120 VAC 1200 W @ 277 VAC 1500 W @ 347 VAC MINIMUM LOAD: None MOTOR LOAD: 1/4 HP FREQUENCY: 50/60 Hz (timers are 1.2x for 50 Hz) ENVIRONMENTAL SPECS OPERATING TEMP Standard: 14º to 122º F (-10º to 50º C) LT Option (PIR): -40º to 122º F (-40º to 50º C) LT Option (PDT): -4º to 122º F (-20º to 50º C) RELATIVE HUMIDITY: Standard: 20 to 75% non-condensing LT Option: 20 to 90% non-condensing (electronics coated for corrosion resistance) ORDERING LOGIC SINGLE RELAY Series WSX Passive Infrared (PIR) WSX PDT Dual Technology (PIR / Microphonics) EXAMPLE: WSX PDT WH Operating Mode1 Blank Auto-On (default) or Vacancy SA Vacancy (default) or Auto-On VA Vacancy only Voltage Blank 120/277 VAC 3472 347 VAC Color3 WH White IV Ivory GY Gray AL Lt. Almond BK Black RD Red DUAL RELAY Series WSX 2P Passive Infrared (PIR) WSX PDT 2P Dual Technology (PIR / Microphonics) EXAMPLE: WSX 2P WH LT Operating Mode1 Blank Pole 1 Auto-On Pole 2 Vacancy (default) 2SA Both Poles Vacancy (defaut) 2VA Both Poles only Vacancy Voltage Blank 120/277 VAC 3472 347 VAC Color3 WH White IV Ivory GY Gray AL Lt. Almond BK Black RD Red NIGHTLIGHT WSX NL WSX PDT NL WSX 2P NL WSX PDT 2P NL Temp/Humidity Blank Standard LT Low Temp Temp/Humidity Blank Standard LT Low Temp EXAMPLE: WSX 2P NL WH Series4 Passive Infrared (PIR) Dual Technology (PIR / Microphonics) Dual Relay, Passive Infrared (PIR) Dual Relay, Dual Technology (PIR / Microphonics) Voltage Blank 120/277 VAC 3472 347 VAC Notes: 1 Operating Modes reprogrammable via push-button except for VA version 2 Wall plates included in white or ivory only for 347 VAC units 3 Matching wall plate provided for 120/277 VAC units 4 Units factory set to Vacancy (Manual On) Operating Mode Color3 WH White IV Ivory GY Gray AL Lt. Almond BK Black RD Red Temp/Humidity Blank Standard LT Low Temp Sheet#: TS-WSX-001A C US LISTED TITLE 24 ASSEMBLED in U.S.A. 5 YEAR WARRANTY WARRANTY 5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Sensor Switch 900 Northrop Road, Wallingford, CT 06492 Phone: 1.800.PASSIVE sensorswitch.com ©2013 Acuity Brands Lighting, Inc. All rights reserved 09/05/13 4 of 4 Submitting Agency: Type: Description: PP20 Project: Notes: Cascade Periodontics POWER PACK PP20 PP20 2P SP20 ® POWER PACK RELAY CONTACT PROTECTION SPECIFICATIONS OVERVIEW Power packs are the heart of the low voltage sensor system. A PP20 Series power pack transforms Class I high voltage (120/277 VAC or 347 VAC) to Class 2 15 VDC for powering remote sensors. The PP20 and the SP20 Series slave pack are also capable of switching lighting loads on and off using their internal relays. Class 2 wire leads connect to 18 AWG or smaller low voltage cable running to the sensors, making installation easy and clean. Power packs also have an elongated chase nipple that allows it to be mounted either directly through a ½ inch knockout into a junction box, or inside an adjacent box for meeting specific local code requirements in ceiling plenums. FEATURES Powers Low Voltage Sensors (PP20/PP20 2P only) Self-Contained Relay(s) Switch Line Voltage Loads Relay Contact Protection Plenum Rated PHYSICAL SPECS SIZE (not including chase nipple) PP20 / SP20: 3.00” H x 2.25” W x 1.88” D (7.62 cm x 5.72 cm x 4.78 cm) PP20 2P: 4.13”H x 3.00”W x 1.88”D (10.49 cm x 7.62 cm x 4.78 cm) WEIGHT: 6 oz MOUNTING: 1/2” knockout COLOR: Black OPTIONS 347 VAC (347) •A llows power pack to be powered by and/or switch 347 VAC LOW TEMP/HIGH HUMIDITY (LT) •S ensor is corrosion resistant to moisture • Operates down to -40º F/C The most versatile power pack is the PP20, which utilizes a patented relay contact protection and can power up to 14 sensors. Dual-circuit control can be handled by two PP20’s, one PP20 2P Series 2-Pole power pack, or a PP20 power pack and a SP20 slave packs. ELECTRICAL SPECS OPERATING VOLTAGE: 120, 240, 277, or 347 VAC RELAY CURRENT REQUIREMENTS: 40 mA SWITCHING LOAD: 20 Amps / Pole OUTPUT VOLTAGE/CURRENT: 15 VDC, 150 mA (PP20/PP20 2P only) CLASS 2: 18 AWG, up to 2000 ft MOTOR LOAD: 1 HP ENVIRONMENTAL SPECS OPERATING TEMP: 14º to 160º F (-10º to 71º C) RELATIVE HUMIDITY: 20 to 90% non-condensing SILICONE FREE ROHS COMPLIANT MOUNTING IN PLENUMS Power packs are plenum rated. Most local codes allow for small plastic controls in return air plenums. To meet all local codes, the units can be mounted inside an adjacent (deep) junction box as shown. RELAY CONTACT PROTECTION The PP20, PP20 2P, & SP20 all have relay contact protection which uses an AC semiconductor, placed in parallel with the power relay, to perform the actual switching function. The switching life of this semi-conductor is virtually infinite because it has no moving parts. The power relay contacts are then used to carry the current during the on state, thereby preventing in-rush or inductive kick from damaging the relay contacts. The result is extremely long relay life (tested to 400,000 cycles). When controlling larger loads of electronic ballasts with high in-rush characteristics, relay contact protection is advised. Power/slave packs without relay contact protection are also availabe (MP20 / MSP20). SYSTEM DESIGN CONSIDERATIONS A local override switch may be upstream or downstream of a PP20. However, if an SP20 or a PP20 2P is being used, the switch(es) should be downstream on the load side of the relay. If power is disconnected to the power pack, all subsequent relays will open, turning off all of the loads. If wiring the local switches before the power pack and slave pack, use multiple PP20’s, one for each circuit. This will allow for one circuit to remain powered, keeping the system operational when the other is turned off. When controlling a dimming circuit, PP20 must be wired before the dimmer, or SP20 may be wired after the dimmer. The SP20 can be used for line voltage auxiliary contact only. INTERFACING WITH ELECTRONIC CONTROL SYSTEMS The Relay Switching System is designed to switch Alternating Currents Only. The relay will not switch DC signal inputs to EMS or Lighting Control Systems. Use model MP20, or “R” for signal relay located in Low Voltage Sensor Heads. C US LISTED TITLE 24 MADE in U.S.A. 5 YEAR WARRANTY ORDERING INFO SERIES # PP20 SP20 [SERIES] [# OF POLES] [VOLTAGE] [TEMP/HUMIDITY] # OF POLES Blank = 1 2P = 2* *not available for SP20 VOLTAGE Blank = 120/277 VAC 347 = 347 VAC** **not available for with 2P TEMP/HUMIDITY Blank = 120/277 VAC LT = Low Temp Submitting Agency: Type: Description: PP20 Project: Notes: Cascade Periodontics POWER PACK Revised 10.30.14 © 2013 Sensor Switch WIRING (DO NOT WIRE HOT) POWERING CAPACITY A power pack’s transformers can supply up to 150 mA of power. Each relay requires 40 mA during the on state. Low voltage remote sensors typically require 3 mA when detecting occupants, and 0.15 mA when in standby. Therefore, each transformer can handle up to 3 relays (including the relay(s) inside the power pack). For example, one PP20 can power its relay (40 mA) and 110 mA of external devices. Because of the ultra low current design of the sensors, up to 14 or more sensors can be connected to a single power pack! If multiple power packs are used together, an additional 110 mA is available. 1 PP20 1 PP20 2P 1 PP20 w/SP20 1 PP20 2P w/SP20 2 PP20 2 PP20 2P Sensors 14 7 7 5 28 14 Sensors w/ R option 8 6 6 5 16 12 Note 1: Only three relays may be controlled with one Power Pack. If more than three circuits are required, multiple power packs must be used. Note 2: The R option adds an isolated low voltage relay to a sensor. Only one sensor with this option is typically needed in a room. Multiple Sensors Controlling One Circuit Multiple Sensors Controlling Two Circuits N RED BLK WHT PP20 2P H N BLK - 120 V ORN- 277 V WHT BLK / ORN BLU BLU RED RED SWITCH LOAD H SWITCH Multiple Sensors Controlling Three Circuits Multiple Sensors Controlling Four Circuits Wiring Multiple Power Packs Together One Sensor Controlling Two Circuits LOAD One Sensor Controlling One Circuit WARRANTY: Sensor Switch, Inc. warrants these products to be free of defects in manufacture and workmanship for a period of 60 months. Sensor Switch, Inc., upon prompt notice of such defect, will, at its option, provide a Returned Material Authorization number and repair or replace returned product. LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and implied warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances shall Sensor Switch, Inc. be liable for any incidental or consequential property damages or losses. T054-004 900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com Submitting Agency: Description: CM 9 Project: Notes: Cascade Periodontics CEILING SENSOR Type: ® CM 9 STANDARD RANGE 360º SENSOR CEILING MOUNT • LOW VOLTAGE • PASSIVE INFRARED (PIR) SPECIFICATIONS FEATURES 100% Digital PIR Detection, Excellent RF Immunity 360º Coverage Pattern Push-Button Programmable User Adjustable Time Delays No Field Calibration or Sensitivity Adjustments Required Convenient Test Mode 100 hr Lamp Burn-in Timer Green LED Indicator LAMPMAXIMIZER® TECHNOLOGY • Protects Lamp Life while Maximizing Energy Savings • Minimum On Timer (15 min default) • Occ. Time Delay (10 min defatult) • LampMaximizer+ Mode Optimizes Lamp Life & Energy Savings (disabled by default) • Switch Counter (in 1000’s) • Total Lamp On Time (in khrs) PHYSICAL SPECS SIZE 4.55” Dia. (11.56 cm) 1.55” Deep (3.94 cm) WEIGHT 6 oz MOUNTING Ceiling Tile Surface 3.5” Octagon Box Single Gang Handy Box COLOR White ELECTRICAL SPECS OPERATING VOLTAGE 12-24 VAC/VDC CURRENT DRAW Standard, 4 mA w/ R option, 16 mA DIMMING LOAD Sinks < 20mA; ~40 Ballasts @ .5mA each RECOMMENDED POWER PACK PP20 ENVIRONMENTAL SPECS OPERATING TEMP 14º to 160º F (-10º to 71º C) STORAGE TEMP -14º to 160º F (-26º to 71º C) RELATIVE HUMIDITY 20 to 90% non-condensing SILICONE FREE ROHS COMPLIANT ORDERING INFO Blank = None R = Low Voltage Relay SENSOR OPERATION The sensor detects changes in the infrared energy given off by occupants as they move within the field-of-view. When occupancy is detected, a DC output goes high and can drive up to 200 mA of connected load. The sensor is powered with 12-24 VAC/VDC and typically operates with a PP20 or MP20 power pack, enabling complete 20 Amp circuits to be controlled. This innovative sensor requires no field calibration or sensitivity adjustments. LAMPMAXIMIZER® This sensor also contains patent pending LampMaximizer technology that allows users to aggressively target energy savings while still protecting lamp life. A minimum on timer, factory set at 15 minutes, helps preserve lamp life by eliminating all lamp cycles shorter than lamp manufacturer recommendations. A standard occupancy time delay is also present that ensures lights turn off (assuming minimum on timer has elapsed) if no occupancy is detected. This timer is factory set at 10 minutes to promote energy savings, but is adjustable between 30 seconds and 20 minutes. These adjustments can be done manually, through the unit’s push-button, or automatically every two weeks through an advanced mode, called LampMaximizer+, that determines the optimum time delay in order to maximize both lamp life and energy savings. Additionally, this sensor maintains statistics on total lamp on time and number of cycles. OPTIONS LOW VOLTAGE RELAY (R) • Enables sensors to interface with other systems (e.g., BMS, lighting panels) • Provides dry contact closure via a SPDT, 1 Amp, 40 Volt relay • Only one relay needed per zone • Changes state when all connected sensors register unoccupied • Relay requires sensor power to function OCCUPANCY CONTROLLED DIMMING (D) • Provides dimming output to control 0-10 VDC dimmable ballasts • Provides a second occupancy timeout period that enables the lights to go to a dim setting before turning off • Adjustable max/min dim setting • Only one sensor per zone needs to have dimming output PHOTOCELL (P) • Auto set-point calibration • Two selectable modes of operation • On/Off mode: Photocell has full control during periods of occupancy • Inhibit mode: Photocell can prevent lights from turning on if adequate daylight is available, but cannot turn lights off PHOTOCELL W/ DIMMING (ADC) • Photocell within sensor maintains total room light level by controlling levels of 0-10 VDC dimmable ballasts • Photocell also has full on/off control during periods of occupancy • Provides a second occupancy timeout period that enables the lights to go to a dim setting before turning off Note: LampMaximizer+ features not available with ADC option LOW TEMP/HIGH HUMIDITY (LT) • Sensor is corrosion resistant to moisture • Operates down to -40º F/C C US LISTED TITLE 24 MADE in U.S.A. 5 YEAR WARRANTY CM 9 [RELAY] [DIMMING/PHOTOCELL] [TEMP/HUMIDITY] RELAY OVERVIEW The CM 9 Series occupancy sensor offers amazing performance and sensitivity to small motions for a standard range Passive Infrared (PIR) sensor. Ideal for small rooms with drop ceilings and areas without obstructions, the CM 9 is a snap to install. Its light weight allows surface mounting to drop ceilings or a ceiling grid. The CM 9 sensor can cover entire private offices or smaller rooms by itself, however it is also the ideal lead sensor for odd shaped rooms. For example, a CM 9 in a restroom vestibule can communicate with a CM PDT 9 Dual Technology sensor in a main stall area. Another application is a CM 9 covering an entrance hall to a classroom and communicating with a WV PDT 16 sensor covering the main room. In both cases the lights would be activated on by the CM 9. For mounting above 15 ft (4.57 m), see the CM 6 Technical Data Sheet. DIMMING / PHOTOCELL CHOOSE ONE ONLY Blank = None D = Occupancy Controlled Dimming P = Photocell ADC = Photocell w/ Dimming TEMP/HUMIDITY Blank = Standard LT = Low Temp Submitting Agency: Type: Description: CM 9 Project: Notes: Cascade Periodontics CEILING SENSOR Revised 06.16.10 © 2010 Sensor Switch COVERAGE PATTERN 9 STANDARD RANGE 360º LENS Note: Screw axis is aligned with a long detection segment • Best choice for small motion (e.g. hand movements) detection • Viewing angle of 56º in a 360º conical shaped pattern • Provides 12 ft (3.66 m) radial coverage when mounted to standard 9 ft (2.74 m) ceiling • 8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft (3.05 to 6.10 m) radial coverage TOP VIEW SIDE VIEW 0 ft 9 3.7 12 1.8 6 0m 0 ft 1.8 6 3.7 12 0m 2.7 3.7 1.8 0m 1.8 3.7 12 6 0 ft 6 12 WIRING (DO NOT WIRE HOT) STANDARD WIRING RED - Power Input (12-24 VAC/VDC) BLACK- Common WHITE - Occupancy State (high VDC for occupied) RED WHT BLK POWER PACK (PP20) (-) VIO w/ WHT STRIPE (+) [D, P, ADC] Photocell / Dimming Options PHOTOCELL/DIMMING OPTIONS (D, P, ADC) BLUE - Direct output to power pack for providing photocell control and/or secondary dim time out. Output is high VDC with occupancy & low light. Output also held high during secondary dim time out. For multi-level control, use two power packs and connect White wire to primary load and Blue to daylight load. VIOLET w/ WHITE STRIPE - Connect to 0-10 VDC control wire (typically Violet) from 0-10 VDC dimmable ballast GRAY from Ballast - Connect to sensor Black wire [R] Relay Option RELAY OPTION (R) GRAY / BROWN - Connected during occupied state VIOLET / BROWN - Connected during unoccupied state Note: Relay is energized during unoccupied state INSTALLATION • Mount sensor directly to a ceiling tile or a metallic grid (two self-tapping screws provided). • Sensor’s mounting holes also align with 3.5” octagon or single gang handy box (screws not provided). • Sensor will detect motions crossing segments more effectively than motions parallel to beams. • For optimal detection, position sensor such that segments are crossed upon entrance and unable to view outside the space. PUSH BUTTON PROGRAMMING Refer to instruction card IC7.001 for default settings and directions on programming the sensor via the push-button. WARRANTY: Sensor Switch, Inc. warrants these products to be free of defects in manufacture and workmanship for a period of 60 months. Sensor Switch, Inc., upon prompt notice of such defect, will, at its option, provide a Returned Material Authorization number and repair or replace returned product. LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and implied warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances shall Sensor Switch, Inc. be liable for any incidental or consequential property damages or losses. TS-CM-003A 900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com