Power Protection for Business-Critical Continuity Tailored Solutions for Power Protection Trouble is Coming Down The Line And You Must Be Prepared Every operation in your business depends upon the instant, around-the clock availability of computers, servers and other electronic systems. If they aren’t working, neither is your company. The Ability To Tailor a Power Solution Is What Sets Emerson Network Power Apart We Know The Importance Of Achieving Protection For Today…And Planning For Tomorrow The decisions you make now are going to impact your ability to efficiently grow into the future. As a power partner that truly understands the importance of genuine reliability, we can implement the best way to achieve it for your operations. Based on our years of experience, we know and understand your current needs for protection — and what it will take to increase your power capabilities as these demands grow. We can help you protect data, hardware and system availability in any combination. Unfortunately, every piece of this equipment your company possesses is subject to the whims of the electricity that powers it. The first step in taking control of this situation is to understand the threats to your system reliability — and exactly what you can do about them. No Matter How Deep Your Protection Needs To Be, We Have The Expertise To Make It Happen We recognize that not everyone requires the same level of power protection. Liebert has the knowledge of critical facilities and equipment that is necessary to determine the exact needs of each application. An extensive range of power protection choices then enables us to match our equipment precisely to these parameters rather than force-fitting a few products to every situation. The result is our unique ability to deliver power solutions that are always on target for the depth of protection specified. There Is A Liebert Power Solution To Meet Every Need No one offers a more comprehensive selection of power products for critical applications than Liebert. Liebert PS (400 VA/600 VA) A Reliable Power Protection For Your PC 4-5 Liebert ITON 600 VA /1000 VA A Reliable Power Protection And Backup Solution For Your PC 6-7 Liebert UPStationTM GXT 2U 1 /2 /3 True Online Double Conversion UPS to Keep Your Business Up and Running 8-9 Liebert UPStationTM GXT 2 (4.5 kVA / 6 kVA) Series 10-11 The New Shape Of Network Power Protection Liebert Series 7400 M (10/30/40/60 kVA) Maximum Protection For Mission Critical Network Applications 20-21 Liebert iTrust 3-Phase UPS System True On-Line Sinewave UPS System For The Networked Economy 22-23 Liebert NX Series The Next Generation UPS System 24-25 Liebert Hipulse UPS (30-150 kVA 1-Phase) Digital UPS For The Digital World & Industrial Automation 26-27 Liebert Hipulse UPS (80-800 kVA 3-Phase) Digital UPS For The High-End Digital World 28-29 Liebert UPStationTM GXT-MT 1-2-3 kVA UPS True Online Double Conversion UPS with Extended Runtime Capability 12-13 Liebert UPStationTM GXT-MT 6 /10 kVA UPS Fit-And-Forget UPS System Power Protection And Power Source 14-15 Liebert Precision Power Center Affordable Packaged Power Management For Higher Power Quality 30-31 Liebert UPStationTM GXT RT 1-3 kVA UPS True Online Double Conversion UPS with Extended Runtime Capabilities with Rack & Tower Compatibility 16-17 Liebert Powersure Panel Transient Voltage Surge Supressor 32-33 Liebert Super 400D (10/20 kVA) 18-19 True On-line DSP Based UPS With Unity Power Factor ASCO Switch Designed To Minimize Downtime On Critical Systems 34-35 No Organization In The Power Protection Business Has More Real-World Experience Than Emerson Network Power Many years of experience allow us to properly respond to any power problem scenario. Our resources include knowledgeable leadership, as well as an outstanding staff of research, design, application and service engineers using the latest technological tools. But the biggest difference in the way we approach your power requirements is the local Liebert Representative, Distributor or Reseller. We are the only company in this business that maintains such a strong local presence on a national and international basis. Specifying and maintaining a high availability power system requires someone who is knowledgeable in all phases of critical systems protection. This resource, coupled with our broad product line, gives Liebert the ability to create a “tailored solution” that will meet your protection needs precisely and efficiently. We don’t have to take the one or two items we happen to have and stretch them to come up with the answer. We give you the best answer every time. Only Liebert can bring together all of the power protection solutions you need to create system availability that is as close to 100% reliability as possible. You Face Many Challenges in the Pursuit of Uptime Is There Really A Problem? “My computer can ride right through a short blip in the power — why do I need anything else?” There Are No Simple Solutions “I have people telling me all I need to do is plug each workstation into a small UPS from the computer store . That’s good enough, isn’t it?” Different Needs Require Different Power Protection Configurations “Should I have a small UPS for each workstation or have everything on one large system . Which is best for my facility?” A Lot Can Happen Between Your UPS And The Equipment It Is Protecting “We have dozens of pieces of networking equipment. How can I make sure that each one is getting exactly the power it needs?” Every Wire Carries The Potential For Trouble “An electrical surge came in through an outside phone line and knocked out our entire communications system. Is this going to happen again?” A Single Source Of Power Simply May Not Be Enough “Adding a second power feed would certainly enhance our availability picture — but who can we talk to about getting it done right?” 2 But There Are Real Solutions You Need Protection From All Power Problems An outage is just the problem you can see. There are many other more frequent power fluctuations — surges, spikes, sags — that you don’t see. These are the conditions that cause the “unexplained” lock-ups. “Out-Of-The-Box” Can Put You Out Of Business Buying a simple off-line UPS down at the computer store may be a good solution for your home PC, but it just doesn’t make sense when your business and productivity are on the line. Protecting critical network and computing systems requires the expertise of someone who understands all the risks you face from poor power quality problems with critical equipment. Centralized Vs. Distributed UPS Protection Liebert has the breadth of products that allows you to implement either a centralized or a one-on-one distributed power protection strategy depending on your requirements. Whatever configuration you choose, you can count on Liebert to make it the best it can be. Benefits, such as increased system security, more efficient maintenance and improved reliability, make a centralized strategy a better choice for larger operations. Proper Power Depends On Proper Distribution In network applications, there may be hundreds of different loads with various voltage requirements, a mix of AC and DC power, plus any number of other electrical Specifications This calls for a distribution system that is designed to maintain the highest levels of reliability and quality between the source of conditioned power and the protected equipment. Power Conditioning And Surge Protection Throughout The Facility Raw utility power is often far too “dirty” for sensitive systems, resulting in lost,or garbled data, unexpected software glitches or shutdowns, even hardware damage. The IEEE recommended practice is to install transient voltage surge suppression (TVSS) protection on every electrical conductor that penetrates a facility shell, including power lines, telephone and other communications links. Maximum Reliability Demands Dual Power Sources If your needs require the highest level of system availability, Liebert has the knowledge and products to implement a dual-power strategy throughout your enterprise. UPS, transfer switching, power distribution and other equipment are all brought together to create the ultimate in reliability. 3 Liebert PS A Reliable Power Protection For Your PC Liebert PS (400 VA/600 VA) A high-performance UPS designed especially to protect low voltage applications and is available in tower design The Liebert PS' features and flexibility makes it the optimal solution for your small electronic devices both at home and office. Applications • TFT Monitors • Personal Computers • Printers • Modems • Routers • Wireless Devices • Non-critical passive devices • Standalone Computers Features • High Frequency Charger Design • Input Fuse Protected • Black Start Mode Available • Separate Low Charge & • Battery Indicator in AC mode • Overload, Discharge • and Overcharge Protection • Output Cable Provided 4 Technical Data MODEL CAPACITY VA/W INPUT Voltage Voltage Range OUTPUT Voltage Voltage Regulation(Batt. Mode) Frequency Frequency Regulation (Batt. Mode) Output Waveform BATTERY Battery Type & Number Back up Time (at a PC load with 15" monitor) Recharge Time Liebert PSA 400 Liebert PSA 600 400VA/200W 600VA/300W 220/230/240VAC 170-270VAC 220/230/240VAC ±10% 50Hz +/-1 Hz Modified Sinewave 12V/4.5Ah x 1pc 12V/7AH x 1pc 5 minutes 8 minutes 10 hours to 90% after complete discharge TRANSFER TIME Typical INDICATOR AC Mode Battery Mode Low Battery at Battery Mode Fault Battery Weak at AC Mode Battery Fault at AC Mode AUDIBLE ALARM Battery Mode Low Battery at Battery Mode Fault Battery Weak at AC Mode Battery Fault at AC Mode PROTECTION Full Protection PHYSICAL Dimension, DXWXH (mm) Net Weight (kgs) ENVIRONMENT Operating Environment Noise Level 2-6ms Green LED lighting Green LED flashing every 4 seconds Green LED flashing every second Red LED lighting Red LED flashing every 2 seconds for 30 seconds Red LED flashing three times every 2 seconds Sounding every 4 seconds Sounding every second Continuously sounding Sounding every 2 seconds for 30 seconds Sounding three times every 2 seconds Discharge, overcharge, and overload protection 176.5x80x230 3.1 3.3 0- 40°C, 0-90 % relative humidity (noncondensing) Less than 40dB 5 Liebert ITON A Reliable Power Protection And Backup Solution For Your PC Liebert ITON 600/1000 A best-in-class UPS with proven reliability. ITON is an uptime solution for your personal computers & peripherals and is available in a compact tower design A line interactive UPS that provides perfect power protection for Small Office & Home Office (SOHO) PC Systems Applications • Home PC • Printers • Clustered network equipment: hubs, routers, bridges • Remote telecommunications units • Desktop Speakers • Office Telecommunications systems • Voicemail and e-mail servers • Test and diagnostic equipment • Chargers • Telecom Ports Features • Auto Sleep Mode • Insta Restart • Power protection for Fax/Modem • Smart Monitoring Software • Smart Microprocessor control • Smart AVR Technology • Communication Port • Overload Protection and alarm 6 Technical Data MODEL CAPACITY VA/W ITON 600 ITON 1000 600 VA/360W 1000VA/600W INPUT Voltage Range Frequency 140-300 VAC 160-270V 45-65 Hz (Auto sensing) OUTPUT Voltage 230V Voltage Regulation (Batt. Mode) +/- 10% Frequency 50Hz +/- 5% 50Hz or 60Hz Frequency Regulation (Batt. Mode) +/- 1Hz Output Waveform Stepped Waveform Overload BATTERY Battery Type & Number Backup Time* (As per the loads) Recharge Time 110% for 5 minutes as “Mains” mode 12V/7AH — 1 PC 12V/7AH — 2 Pcs 15-22* mins 30 min typical* (with 1 PC) 8 hours to 90% after complete discharge TRANSFER TIME Typical 4-8 ms 4-6 ms INDICATOR (LED Bar Graph) AC Mode Green Lighting Backup Mode Green flashing Fault AUDIBLE ALARM Backup Mode Low Battery Overload Battery Replacement Fault PROTECTION Full Protection PHYSICAL Dimension (mm), DxWxH Net Weight ENVIRONMENT Operating Environment Noise Level The 1st green lighting; The 2nd to 5th green gradually lighting indicating load capacity The 1st green flashing; The 2nd to 5th green gradually Green flashing lighting indicating batteries capacity The red lighting Green Lighting Sounding every 10 seconds Sounding every second Sounding every 0.5 seconds Soundingevery 2 seconds Continuously Sounding Discharge, overcharge, and overload protection 330x100x140 6 kg 369x141x181 13.5 kg 0-40 C, 0-90% relative humidity (non-condensing) Less than 40 dB INTERFACE RS-232 Support Windows 98/NT/ME/2000/2003/ XP, Linux, HP-UX, IBM AIX, Sun Solaris, Unixware, Free BSD, Mac OS and Compaq True 7 Liebert GXT 2U True Online Double Conversion UPS To Keep Your Business Up And Running UPStationTM GXT 2U in Rack and Tower Mode A high-performance UPS with proven reliability, custom configurability, hot-swap internal batteries and extendible runtime in a compact tower design. The GXT2 features and flexibility make it the optimal solution for small server room, networking and telecom applications that require reliable, continuous and quality power. 8 Applications • LAN and WAN servers • Clustered network equipment: hubs, routers, bridges • Remote telecommunications units • Office Telecommunications systems • Voicemail and e-mail servers • Test and diagnostic equipment • Engineering network servers • Factory floor protection of micro processor controlled equipment • Mission critical devices Features • True on-line design • Configurable as rack or tower • Wide input voltage window allows • UPS support without going to battery, • extending systems availability • Built-in Surge Suppression • User replaceable batteries without • removing GXT 2U from rack • Compatible with new SNMP / Web Card • Compatible with Multiport 4 or 8 • Compatible with RelayCard INT • Compatible with MultiLink Technical Data Description 1 kVA UPStation GXT 2U 1000 2 kVA UPStation GXT 2U 2000 3 kVA UPStation GXT 2U 3000 Input Parameters Nominal Voltage Voltage Range Frequency Range Power Factor 230 VAC 119 - 280VAC ( Load Dependent ) 40 Hz - 70 Hz > 0.97 Output Parameters Capacity Voltage Voltage Regulation Frequency Regulation THD Overload Capability ( with transfer to bypass ) Efficiency Crest Factor 1 kVA / 0.7 kW 2kVA / 1.4 kW 3kVA / 2.1 kW User Configurable 200 / 208 / 220 / 230 / 240 VAC + / - 3% Steady state + / - 5% if synchronized to mains, + / - 0.1 Hz free running or on battery operation ( when not synchronized to mains ) <=3% (100% Linear Load), <=5% (100% Non-Linear Load) Upto 130% - 10 Secs 200% - 8 cycles > =88% (AC AC) minimum 3:1 max Battery Parameters Type Recharge Time Battery Back-up Time 21 V/7 AH Sealed, Lead/Acid. 12V / 9 AH Sealed,Lead/Acid Maintenance Free Maintenance Free Max.5 hours to 95% capacity (after full discharge into 100% Load) 13 mins 8 mins 8 mins Environmental Conditions Storage Temperature Humidity Noise Level Electronic Discharge -15OC to +15OC 0 to 95% Non Condensing <50 dBA Compliant to ENC61000-4-2, LEVEL 4 (15 kV through air, 8 kV contract) Dimensions ( Unit ) WxDxH Weight 87 X 547 X 430 22.6 kg 87 X 547 X 430 24.7 kg 87 X 618 X 430 31.9 kg Agency Safety RFI / EMI Surge Immunity Transportation EN50091-1-1, CE compliance mark, for both Low Voltage and EMC Directives C-Tick, AS 62040-2, EN 50091-2, Class B EN 61000 4-2, 4-3, 4-4, 4-5 ISTA Procedure 1A Typical Autonomy is calculated at approximately 80% load 9 Liebert GXT 2 (4.5 kVA / 6 kVA) The New Shape Of Network And Power Protection UPStationTM GXT 2 (4.5 kVA / 6 kVA) in Rack and Tower Mode A high-performance UPS with proven reliability, custom configurability, hot-swap internal batteries and extendible runtime in a compact rack and tower design. The GXT2 features and flexibility make it the optimal solution for your small & medium server, data room, networking and telecom applications that require reliable, continuous and quality power. 10 Applications • LAN and WAN servers • Clustered network equipment: hubs, routers, bridges • Remote telecommunications units • Office Telecommunications systems • Voicemail and e-mail servers • Test and diagnostic equipment • Engineering network servers • Factory floor protection of micro processor controlled equipment • Mission critical devices Features • True on-line design • Built-in PFC circuit • Wide input voltage window allows • UPS support without going to battery, • extending systems availability • Builtin Surge Suppression • Compatible with new SNMP / Web Card • Compatible with Multiport 4 or 8 • Compatible with RelayCard INT • Compatible with MultiLink • External plug and play Battery cabinets available • Configurable as rack or tower Other product features of the Liebert GXT2 include • Self-diagnostics • Built-in serial communications for use with Liebert • MultiLinkTM Automated Shutdown Software • Intellislot TM communications port • Built-in closure signals • Includes Windows-based configuration program Technical Data Output Ratings Output Power Nominal Output Voltage Output Voltage Regulation Output Voltage Distortion -With 100% Linear Load Nominal Output Frequency Output Frequency Tolerance ( Phase locked with Mains ) Overload at 0.7 pf ( Load is transferred to Bypass After pre-determined time Load Power Factor Range 4.5 KVA/3.15Kw, 6 KVA/4.2Kw 230 VAC +/-2% < 3% 50 Hz 46.5 Hz to 53.5Hz +/-3.5 Hz Synchronized to mains 125% for 10 Sec 0.7 lagging to unity Input Ratings Nominal Input Voltage Permissible Input Voltage Variation at Full Load Nominal Input Frequency Permissible Input Frequency Variation Power Factor at Full load 220/230/240 VAC 176-276 VAC 50 Hz 40 to 70 Hz > 0.97 Battery Details (External) Nominal DC Bus Voltage Number of Blocks of SMF Batteries Types of Batteries Supported Recharge Time up to 100% Capacity 240 VDC 20 blocks of 12 V each Sealed Maintenance Free (SMF) 10 hours to 12 hours Physical Parameters Width X Depth X Height (mm) Weight 221x547x430 67 kg Environmental Parameters Operating Temperature at Rated Load Storage Temperature Relative Humidity Noise 0 to 40oC - 15 to + 50oC 0 to 95% RH < 55 dB Agency Safety RFI / EMI Surge Immunity Transportation EN62040-1-1, TUV/GS AS 62040-2, EN 50091-2, Class A CE EMC Directive EN 61000 4-5 Level 3 criteria A ISTA Procedure 1B 11 Liebert GXT-MT 1-3kVA UPS True Online Double Conversion UPS With Extended Runtime Capabilities Liebert GXT-MT 1-3kVA UPS Applications • Small Size Data Center • Telecommunication, VoIP • Small Office Network • Data Warehouses Liebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions. It is available in adaptable battery architecture & compact tower configuration. • Medical Diagnostics • Process Automation Equipments • Small Research and Functional Laboratories Features • Extended Runtime Capabilities • Flexible (Site Specific) Battery Configuration • Compact Tower design. • Generator Compatible • Class B Electromagnetic interference (EMC) • compatible • Ultra wide input voltage range • High capacity Battery Charger for GXTL • High input power factor & low THDi Note: Liebert GXT-MT standard model is provided with an internal battery. It is also available in long Back-up mode 12 Technical Data Electrical Model Rating Input GXT 1000-MT GXT 1000-MT 1000VA/700W GXT 2000-MT GXT 2000L-MT 2000VA/1400W 1-phase, plus PE 220Vac / 230Vac / 240Vac 1. 160~300 Vac full load 2. 110 Vac half load 50 / 60 Hz 0.97 (conditions: rated voltage, full pure resistive load, fully charged battery) < 10% Input system Rated voltage Voltage range Frequency Power factor Input THDi 46-54 Hz Frequency range Output Output system Power factor Voltage Line regulation 1-phase, plus PE 0.7 220Vac / 230 Vac / 240 Vac ±2% <_2%(0~100% linear load) Voltage harmonic distortion (rated input voltage, rated input frequency) Dynamic variation < _3%(0 ~100% linear load) < _6%(0 ~100% non-linear load) <5% in 20 ms Frequency Frequency range Inverter overload capability (in Normal mode, 25°C) 50 / 60 Hz ±0.02Hz 46-54 Hz / 56-64 Hz Inverter overload capability (in Battery mode, 25°C) Crest factor 108%~150% 30s >150% 300ms 108%~150% 30s >150% 300ms 3:1 Bypass Operating Voltage 300% for 5s Transfer time 200% for <_60 mins Normal<->Battery: 0ms DC Component External battery voltage Charging current GXT 3000-MT GXT 3000L-MT 3000VA/2100W <_200mV 96Vdc 36Vdc 1A 4A 1A 8A 1A 8A Battery Qty x Volts x Capacity Manufacturer / Model Typical Autonomy Time Autonomy at Half Load Charging Duration Noise (within 1m) Protection 3x12Vx7.2Ah CSB/GP 1272F2 or Panasonic Equivalent 12 Minutes 20 Minutes 8x12Vx7.2Ah 8x12Vx7.2Ah CSB/GP 1272F2 CSB/HRL 1234W or Panasonic F2 or Panasonic Equivalent Equivalent 15 Minutes 9 Minutes 26 Minutes 16 Minutes 80% of battery capacity in 4 hrs (standard type) GXT1000L-MT, GXT2000L-MT, GXT3000L-MT: <45db IP20 (static state) Environmental Item Ambient Temperature Relative Humidity Altitude Storage temperature Normal Range 00 C-400C Less than 90% Condensing Lower than 1000m; no derating; 1000~1500m; 1% derating for every 100m rise -00 C-400C (excluding battery) 13 Liebert GXT-MT 6/10 kVA UPS FIT - AND - Forget UPS System Power Protection And Power Source Liebert GXT-MT 6/10 kVA UPS Applications • Small & Medium Size Data Center • Telecommunication, VoIP • Office Network • Data Warehouses Liebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions. • Process Automation Equipments • Educational Institutes • Small Retail Out lets Features • Parallel up to 3modules • Extended Runtime Capabilities This high performance UPS with proven reliability is available in compact tower design • Compact Tower design • Generator Compatible • Class B Electromagnetic interference (EMC) • compatible (EN50091-2) • Ultra wide input voltage range • High capacity Battery Charger for GXTL • High input power factor & low THDi 14 Technical Data Electrical Model Rating Input Input system Rated voltage Voltage range Frequency Power factor Input THDi Frequency range Output < 2%(0 ~100% linear load) < 6%(0 ~100% non-linear load) Crest factor Bypass Auto retransfer Transfer time Communication Port External battery voltage Charging current ±5% in 60 ms 50 / 60 Hz ±0.05Hz 105%~130% 10min, transfer to bypass >130% 1sec, transfer to bypass turnoff output >105% 10sec, 3:1 Yes Normal<->Battery: 0ms RS 232 as standard 240Vdc 4.2A Capacity Charging duration Dimension (W x D x H) Weight 46-54 Hz Voltage harmonic distortion (rated input voltage, rated input frequency) Dynamic variation Inverter overload capability (in Battery mode, 25°C) Relative Humidity 1-phase, plus PE 220Vac 180-270 V 50 Hz > 0.98 (conditions: rated voltage, full pure resistive load, fully charged battery) < 10% 1-phase, plus PE 0.7 220Vac / 230 Vac / 240 Vac ±1% <1%(0~100% linear load) Inverter overload capability (in Normal mode, 25°C) Noise (within 1m) Protection Operating Temperature Installation Height GXT 10000L-MT 10000VA/7000W Output system Power factor Voltage Line regulation Frequency Battery GXT 6000L-MT 6000VA/4200W 20 nos. of 12V Depends on battery capacity <55db IP20(static state) 0 - 40o C < 1000 m < 95% 260 mm x 570 mm x 717 mm 6kVA / 90 kg 10kVA / 93 kg 15 Liebert GXT- RT 1-3kVA UPS True Online Double Conversion UPS With Extended Runtime Capabilities With Both Rack & Tower Compatibility Liebert UPStation GXT-RT 1-3kVA UPS Applications • Small Size Data Center • Telecommunication, VoIP • Small Office Network • Data Warehouses Liebert GXT-RT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions. It is available in adaptable battery architecture and both rack and tower-mountable configuration to suit your specifications. 16 • Medical Diagnostics • Process Automation Equipments • Small & Medium Functional & Research • Laboratories Features • Extended Runtime Capabilities • Flexible (Site Specific) Battery Configuration • Rack / tower Adaptability • DSP controlled Online double conversion • Generator Compatible • “Mute” design • Class B Electromagnetic interference (EMC) • compatible • Ultra wide input voltage range • High capacity Battery Charger • High input power factor & low THDi Technical Data Model Rated Out put Input Parameters Rectifier type In put volta ge Input volta ge range Input frequenc y range In put power factor Battery Battery type Battery strin g rated voltage Output Parameters Inverter type Output active power Output socket type Output voltage Output frequency Output VTHD (Volta ge Total Harmonic Load maximum crest factor Step load capability Overload capability S ystem parameters and standard Efficiency Switching time (mains failure ) Noise Panel dis play Dimension (width x de pth x hei ght) in mm Height in U Wei ght (long backu p time) Safet y EMC Immunit y Surge protection Protection level Communication and mana gement Interface type Web /SNMP card Environment Operating temperature Relative humidity Altitude GXT1000L-RT 1kVA GXT2000L-RT 2kVA GXT3000L-RT 3kVA Uses most u p-To-date IGBT and PFC (power factor y correction ) 220Vac, sin gle phase three-wir e 120 to 288Vac 50Hz±2%, 5%, 7% and 10%, user settable At least 0.99 Valve-re gulated lead-acid maintenance free batter y 36Vdc 72Vdc 72Vdc Uses most u p-to-date IGBT 1.4kW 2.1k W I E C IEC/Terminals 220Vac, sin gle phase three-wir e 50Hz±2% <2% for linear load, <5% for non-linear load 3:1 (Com ply with IEC62040-3 ) 100% Operation <105% continuous 105% to 125% rated load for 5min 125% to 150% rated load for 1min >150% rated load for 10s 0.7k W I E C >88% <43dB 2U 7.8kg >89% 0ms <45dB LED 440 X 400 X 87 2U 9.6kg EN62040-1-1, CE Marked EN50091-2, class B EN50082-1 IEC60664-1, Level IV IP21 >90% 2U 10kg Serial port/dry contact / SNMP card Optional parts 0 to 40 Celsius degrees (UPS) and 25 Celsius degrees±5 (Batter y) 0 to 95% no-condensing 1500m (as per IEC 62040-3 ) Value-added Optional Parts WEB/SNMP card ModBUS card Equipment Room Signal Adapter UPSite Plus monitoring system 17 Super 400D (10/20 kVA) True On-line DSP Based UPS With Unity Power Factor Applications • Facility-wide networks • Medical equipment • Industrial processes • Large computer rooms The Liebert Super 400D is a true On-line sine wave UPS system that provides the user with clean computer grade power for continuous operation of his critical load, regardless of any disturbance on the upstream AC power. The system offers many innovative features to give the user maximum reliability and flexibility at the lowest operating cost. With Liebert Super 400D UPS system, you have complete peace of mind. Features & Benefits 10,20 Super 400D (10/20 kVA) Low Input Current Harmonic Distortion of less than 5% Unity Input Power Factor Temperature compensated Battery charging to enhance the Battery life Battery test facility Reverse Phase sequence operation Auto retransfer facility DSP and Dual microprocessor based system 18 Technical Data Input Parameters Bypass Parameters DC Parameters Output Parameters Parameters Mechanical Parameters Environmental Parameters Input Voltage Input Voltage Variation Input Frequency Input Frequency Variation Power walk in Power Factor at rated load Operation with Reverse Phase Sequence 415V, 3-Phase, 4 wire - 30%, +25 % 50 Hz +/- 10% Progressive over 10 seconds 1.0 (Unity) Possible Bypass Supply Voltage 220/ 230/ 240V AC Nominal DC bus voltage Permissible DC voltage variation DC bus OV trip End of discharge DC bus Types of batteries supported Nominal battery float voltage Max. batt.charging current DC ripple D.C. Voltage Regulation 356V 260V - 410V 410V 260V SMF 356V 7.0A < 2% rms ± 1% Output Voltage Frequency Power rating at 0.8 p.f. Power rating at 1.0 p.f. Overload Rating Transfer time synchronized unsynchronized - 220/ 230/ 240 VAC 1 Phase 50 Hz 10 kVA, 20 kVA 8 kW, 16 kW 110 % for 60 minutes 125 % for 10 minutes 150 % for 1 minute 100 % with Crest Factor of 3:1 +/- 1% +/- 10% 10 millisecond +/- 0.1 % ± 1Hz, ± 2 Hz, ± 3 Hz 0.2 \0.4 hz/sec < 3 % at Non linear load < 2 % at linear load 0 millisecond 20 millisecond Voltage limits for Inv. operation SMF battery Float Charge Voltage Max. Charging current 260V DC to 410V DC 26 Blocks of 12 V each 356 VDC 7.0 A Height x Depth x Width Weight Ventilation Cable entry Colour / Panel finish Base castor wheels 1150mm x 650mm x 450mm 275kg Forced - Air cooled Front end - Bottom Structured dark Grey Yes Operating Temperature Storage Temperature Relative Humidity Altitude Temperature Derating Altitude Derating 0 C to 45 C, continuous 0oC to 70oC 95% RH 1000 Meters o o 1.5% per C between 40 & 50 C 1 % per 100m between 1000m - 2000m Max. Non-linear load permissible Output Voltage regulation Transient response for 100% load change Recovery time Freq. stability unsynchronized synchronized Max. rate of change of Frequency Output Voltage Distortion o o 19 Series 7400 M (10/30/40/60 kVA) Maximum Protection For Mission Critical Network Applications Series 7400 M (10/30/40/60 kVA) in Rack and Tower Mode Applications •Information Technology The Liebert Series 7400 M addresses all the power quality needs of today’s networked economy by providing a perfect sinewave output voltage with stable frequency, over and above offering many other important customer values. 20 Servers (LAN, WAN, e-mail, ERP, Web, Digital Archives, IntraNet) Networking (Routers, Hubs, Switches, Multiplexer, Bundler, Unbundler, Modems) •Banks, Insurance and Financial Services •Telecommunications, Billing Computers •Medical Diagnostics, MRI, CT Scan, Cath Lab •Process Automation, Small processes, Light Robotics Features •On-line double conversion UPS: makes your load independent from both main's voltage and frequency. Ensures Server-grade high quality of power •IGBT technology PWM inverter switching technology: provides your load with perfect sinewave voltage •High efficiency performances: lower cost of ownership •Excellent performance with either 100% unbalanced and 100% non-linear loads with crest factor upto 3:1 without derating: no need to care about the distribution of your single phase loads between output phases nor to oversize the UPS •Super-servers, mini-computers and multi-processing systems •Advanced battery management systems with programmable battery testing: constantly monitors the the health of the battery pack keeping the battery ready to work for emergency situations •Small footprint and convenient maintenance access: ease of positioning and saving of floor-space •Inverter with high overload capability: no need to oversize UPS; reduced initial investment •Inverter output protected against short-circuit: high protection to the inverter hence more availability of the systems; Investment protection •Zero footprint for optional tuned filter for the input: lower cost of ownership because of space saving and reduced electricity bill Technical Data Model 10 30 40 60 Power 10kVA 30kVA 40kVA 60kVA Output Power 8kW 24kW 32kW 48kW Power factor 0.8 Input Voltage 380/400/415 V Frequency 50 or 60 Hz Power Factor > 0.9 (Additional Filter) THDi < 10%-15% with Battery charging Voltage Window + 10%-20% without battery charging Output Voltage 380/400/415V Frequency 50 or 60 Hz Voltage stability - static +_ 1% - dynamic +_ 5% Voltage distortion - linear load 1% typical - non-linear load 5% max (with 3:1 crest factor) Overload capability three-phase: 110% for 60 mins, 125% for 10 Mins, 50% for 1 min Single-phase: 200% for 30 secs Maximum permissible non-linear load 100% (with 3:1 crest factor) Physical Weight 480kg 540kg 620kg Width 710mm 710mm 710mm Height 1420mm 1420mm 1420mm Depth 800mm 800mm 800mm 20 kVA model also available on request. Operating Temperature is 40oC. However ratings can be selected for ambient temperature upto 50oC 21 Liebert iTrust 3-Phase UPS System True On-Line Sinewave UPS System For The Networked Economy The Liebert iTrust 3-phase is a true on-line 3 phase UPS system (sine wave output) that provides the user with clean computer grade power for continuous operation of his critical load, regardless of any disturbance on the upstream AC power. The system offers many innovative features to give the user maximum reliability and flexibility at the lowest operating cost. With Liebert iTrust 3-phase UPS system, you have complete peace of mind. 22 iTrust 3-Phase UPS Applications • Telecommunications Facilities • Data processing • Medical imaging equipment • Industrial process equipment • Functional & Research Laboratories • Large Format Departmental Stores & Multiplexes Features • Parallel for Redundancy or Capacity for up to 4 units • Full Digital Signal Processing using the latest DSP technology • Wide Input Voltage Range • Low Current Harmonic Distortion of less than 3% • High Input Power Factor • High Overload and Short-Circuit Capacities • Intelligent Battery Management • Large LCD Display and Mimic Panel for Real-time information • MTBf over 5,00,000 hrs ensuring reliable power supply • Power supply efficiency over 97% through Bypass during good • mains supply thus minimizing operating cost Technical Data Capacity Rectifier Input Input Voltage AC power input Power factor Harmonic current Highest operating voltage Lowest operating voltage Input current limit Frequency range Bypass input Input voltage Input voltage range AC power input Frequency range Output Voltage regulation [Balanced load] Voltage transient response Voltage distortion [linear load] Voltage distortion [nonlinear Power factor Frequency syn. Range Frequency regulation [Battery mode] Phase displacement [Three-phase] Overload capability [inverter] Overload capability [bypass] Ratio of output current peak Value to RMS value Transfer time [normal mode] System Display EMC/EMI conduction Radiation Harmonic Immunity MTBF [single UPS] MTBF [1+1parallel operation System] Audible noise at 2m Cross current without Load [1+1] Cross current without Load [3+1] Current unbalance rate [1+1] Current unbalance rate [3+1] Insulation resistance Dielectric strength Surge immunity 30kVA 40kVA 60kVA 380/400/415v [line-to-line voltage] three-phase three-wire >0.99 <3% +15% -45% When input current is smaller than 115%in, UPS can operate continuously; when input Current is 115-140%in, the UPC can operate For 5 minutes; and when input current is 140-165%in, the UPC can Operate for 1 minute; current limiting function is activate When input Current is over 165%in [in the Rated output current at full load] 50hz+ -10% 380/400/415v[line-to-line voltage] +-10% three-phase three-wire 50hz +-10% 380/400/415v+1% [+_5% adjustable] +-5%[0 100% linear load] THD<1%[line-to-neutral voltage] [battery float charge state, rated Balance load] THD<4%[line-to-neutral voltage] [battery float charge state, Load} rated balance load] 0.8 [lagged] 50hz +-2hz +-0.1% 120 +-1 [balanced load or unbalance load] 105%<load<125%, transfer to bypass mode after 10+-0.1 min; 125%<load<150%, transfer to bypass mode after 1 minute; When load>150%, transfer to bypass mode after 200 ms 135% rated current continuously 135% 170% for 1 minute > 170, shutdown in 2s 1000% rated current for 20 ms [a standard for selecting static switch] 3:1 0[uninterrupted transfer], 15ms [interrupted transfer] <60db LCD + LED EN 50091-2 EN500919-2 CLASS-A IEC 1000-3-4 EN 61000-4-2,3,4,6,8,9,11 level III, EN 61000-4-5 IV 150,000 hours 400,000 hours <65db <1A <2A Protection <2% <3% >2m [500vdc] [input to earth, output to earth] 2820vdc, leakage current lower than 3.5ma 1min without arc Satisfy the class IV requirements specified by IEC60664-1, The ability to withstand 1.2/50us not lower than 6kv/3ka Ip21 Installation Cable access mode Physical dimension [WxHxD] mm Weight [kg] top/bottom cable access modes optional 600x1400x860 800x1800x860 528 654 800x800x860 811 23 Liebert NX Next Generation Uninterruptible Power Systems Liebert NX – the next generation, true on-line, double conversion digital UPS – is designed to appropriately address the “Hi-Availability Quality Power” need of B2B and B2C businesses. Innovation, simplicity and low cost of ownership have been delicately converged in Liebert NX to offer you the highest capital investment return. With the Liebert NX, you can rest assured that you have high nines quality power for your critical business applications. Liebert NX comes in six popular ratings: 30, 40, 60, 80, 100 & 120 kVA. 24 Liebert NX Applications •Server Rooms and Mid-sized Data Centers •Telecommunication (Fixed, WiLL & Mobile) Billing & Reporting Systems •Networks (LAN, MAN & WAN), InfoCom and WiFi Hot Spots •Industrial Process & Motion Automation for Mid-sized plants •Medical Diagnostic / Imaging Equipment Features •Stratified cooling techniques •Versatile and simultaneous communication facilities •Compact active and passive footprints •Capability to handle 0.9 leading power factor loads •Capability to handle 100% unbalanced loading •Backfeed protection •User f lexibility in selecting effective conÞguration for the application •Large and user-friendly LCD display in twelve different languages •Compatibility to VRLA (SMF), LATB, Nickel Cadmium batteries •Black start facility Benefits • Hi-Availability of Quality Power • Reduced Cost of Ownership • Upstream Green Power • Ease & Simplicity in Scalability & Redundancy • Investment Protection Technical Data Models Rated Power @ 0.8 PF Rectifier Input Rectifier Type Input Voltage Input Frequency Input Current THD Input Power Factor Power Walk-In Bypass Input Input Voltage Battery Battery Type End-Cell Voltage DC Ripple Current (float) DC Ripple Voltage (float & const V Ch) Temp. Comp. Charge [kVA] 10 Nxe 15 20 30 40 60 80 Nxa 100 120 140 [s] IGBT-based Vector Controlled PFC (PF Corrected) 380 / 400 / 415 (Accepted from 305 to 477 without batt. Use) 50 or 60 (Accepted range from 40 to 70) <3% (without any Filter) =0.99 (without any Filter) 5 to 30 (selectable) [Vac] 380 / 400 / 415 [Vdc/ Cell] VRLA (Valve Regulated Lead Acid) or Wet / Flooded or NiCd Selectable from 1.60 to 1.90 (for VRLA) [Vac] [Hz] 160 200 <5% (of C10 AH capacity) RMS value <1% (RMS value) Standard (where internal batteries 10, 15, 20, 30, 40 kVA) and Optional (for all other battery configurations) Output Inverter Type Output Power Output Voltage Output Frequency Output Voltage THD Max. Load Crest Factor Transient Volt. Resp. Max. Leading PF Load Voltage Displacement Overload Efficiency [kW] [Vac] [Hz] [ms] [°el] 8 IGBT-based Vector, Repetitive & PI Controlled 16 24 32 48 64 80 96 112 128 380 / 400 / 415 +/- 0.5 Regulation (3-phase RMS average) 50 or 60 with +/- 0.05 Regulation 1% (max) 3:1 (compliant with IEC 62040-3) 10 to recover ±5% of Nominal Voltage for 0% to 100% or 100% to 0% step load Up to 0.9 120°+/-10 el (with 100% unbalanced load) 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute 12 AC-AC Physical Parameters Width Depth Height Weight (approx.) without batt. UPS Enclosure IP Standards up to 96 [mm] [mm] [mm] [kg] 600 700 1400 180 204 600 825 1600 204 700 825 1800 312 341 401 445 720 IP 20 (even with open front door) 1000 825 1800 720 1050 1200 1350 IEC 62040-3, IEC 62040-2, IEC 62040-1-1, IEC 60146-1-1, IEC 61000-4-2, 4, 5, 6, 8,11, EN 50091-1-1, EN 50091-2, EN 50091-3, EN 60950, EN 60529, ANSI C62.41 (IEEE 587) Class-A (Applicable for both Radiated & Conducted) EMC Class Environmental Storage Temp. Operating Temp. Relative Humidity Maximum Altitude above Mean Sea Level 160 [°C] [°C] [m] -20 to 70 (UPS) & -20 to 30 (Battery) 0 to 40 (UPS) & 25 +/-5 (Battery) 0 to 95% (non-condensing) 1000 (as per IEC 62040/3) 25 Liebert Hipulse UPS Digital UPS For The Digital World & Industrial Automation Liebert Hipulse UPS (30-150 kVA 1-Phase) in Rack and Tower Mode From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them all efficiently and effectively. Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against power quality problems as well as complete power failure. 26 Applications • Facility-wide networks • Medical equipment • Industrial processes-Automation • Transport Automation • Large Computer Rooms Features • On-Line Double Conversion • IGBT-based PWM Inverter • Wide input voltage tolerance (+10/-15%) • Wide input frequency tolerance ( 5%) • Automatic battery testing • Common battery sharing kit (optional) with 1+1 configuration • Built-in maintenance bypass (Single and 1+N Models) • Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA • UPS modules in Dual Bus configuration using optional HiSync on the Upstream (with UPS), HiSwitch in the downstream (after UPS) and load-end SmartSwitches • Provision to use any type of battery: Wet cells (Tubular or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance free and Nickel Cadmium • Field settability of end-cell voltage of the battery • Intelligent web communications and automatic graceful computer shutdown operations • N form software for full-scale and cost-effective monitoring • Site scan web solution tool for online monitoring Technical Data HIPULSE UPS System Nominal rating [KVA](0.8 pf) 25 40 60 80 105 130 150 895 895 895 895 895 895 895 900 2110 900 2110 900 2110 1250 2110 1640 2110 1640 2110 1640 2110 Physical characteristics Depth[mm] Width[mm] Height[mm] Input Voltage frequency Power factor Output Voltage stability Voltage stability -steady state 100% load Step Frequency Frequency Stability - Synchronized with the bypass supply - Auto -synchronized Overload capacity from inverter at nominal voltage Short circuit current from inverter Voltage distortion with linear load Voltage distortion with 100% Non linear load Max deliverable Power with Non linear load(CF=3:1) Output Voltage Dissymmetry with 100% Unbalanced load Environment Ambient Temperature Operating Continuous Storage Relative Humidity Max operating altitude with derating Acoustic noise at 1 meter from Panel -Front Cable Entry Cabinet Finish Front ,Rear ,Top Cover Front Door & Slide door Construction Degree of protection for enclosure Ventilation 380/400/415V(+10/-15%)-3ph-3W 50 or 60 Hz +/- 5% 0.8-0.92 230/1 ph (+/-)1.5% (+/-) 5% (+/-)1% (+/-) 0.1% 110% for 60 minutes,125% for 10 Minutes,135-150% For 1Minute 1.5 in for 5 seconds(in accordance with EN50091-1-1) 2% max <5%Ph/N(distorted load as per En 50091-3) 100% 2% **rating can be selected for ambient temperature upto 50C 0 to 40 C (**) Max 40 to 8 Hrs (- 25C) to 70C 90% non condensing type at 20 C 1000 meters from MSL 57 to 73 dbA (depending on the KVA) Bottom Structure White Epoxy Polyester Structure Black Epoxy Polyester IP 31 Standards forced Air Cooling with internal fans 27 Liebert Hipulse UPS (80-800 kVA 3-Phase) Digital UPS For The High-End Digital World Liebert Hipulse UPS (80-800 kVA 3-Phase) in Rack and Tower Mode From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them all efficiently and effectively. Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against power quality problems as well as complete power failure. 28 Applications • Facility-wide networks • Medical equipment • Industrial processes • Server Farms • Telecommunication • Data Centers in IT/ ITES/ BPOs • Server & Networking • Entertainment & Media Features • On-Line Double Conversion • IGBT-based PWM Inverter • Wide input voltage tolerance (+10/-15%) • Wide input frequency tolerance ( 5%) • Automatic battery testing • Common battery sharing kit (optional) with 1+1 configuration • Built-in maintenance bypass (Single and 1+N Models) • Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA • UPS modules in Dual Bus configuration using optional HiSync on the Upstream (with UPS), HiSwitch in the downstream (after UPS) and load-end SmartSwitches • Provision to use any type of battery: Wet cells (Tubular or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance free and Nickel Cadmium • Field settability of end-cell voltage of the battery • Intelligent web communications and automatic graceful computer shutdown operations • N form software for full-scale and cost-effective monitoring • Site scan web solution tool for online monitoring Technical Data Hipulse UPS System Nominal Rating [kVA] (0.8pf) Rectifier Type 80 6p 12p 120 6p 12p 160 6p 12p 200 6p 12p 300 6p 12p 400 6p 12p 500 12p 600 12p 800 12p 1890 1640 2280 1000 2460 2460 3200 3200 4400 2000 1850 2540 2400 3100 4200 4500 5050 Physical Characteristics Depth [mm] Width [mm] Height [mm] Weight [kg] 900 1300 1250 1890 1250 750 1120 1000 1475 1200 875 1890 1250 1900 1725 1350 Input Voltage Frequency ITHD Power Factor 380/400/415V (+10/-15%) 3Ph 4w 50 or 60 Hz +/-5% 4-10% with optional input filter 0.90- 0.94 with optional input filter Output Voltage Stability Voltage Stability -Steady State 100% Load Step +_ 1% +_ 5% Frequency 50 or 60 Hz Frequency Stability -Synchronised with the bypass supply - Auto Synchronised Overload capacity from inverter at nominal voltage -3ph -1ph Short circuit current from inverter -3ph - 1 ph Voltage Distortion With Linear Load Voltage Distortion With 100% Non Linear Load Max. Deliverable Power With Non-Linear Load ( CF =3:1 ) Max Unbalanced Load Voltage Displacement With 100% Unbalanced Load Output Voltage Dissymmetry With 100% Unbalanced Load 380/400/415V 3Ph 4w +_1% +_0.1% 10% for 60 minutes, 125% for 10 minutes, 135-150% for 1 minute 200% for 30 seconds 1.5 In for 5 seconds 9in accordance with EN 50091-1-1 2.9 In for 5 seconds 2.2 In for 5 seconds <1% <3% Ph/ Ph, < 5% Ph / N (distorted load as per EN 50091-3) 100% 100% 120o +_1o el 2% 29 Liebert Precision Power Center Affordable Packaged Power Management For Higher Power Quality Liebert Precision Power Center Liebert delivers the packaged power solution through precision power center (PCC), creating high quality power to protect the operation of a critical facility. It is a all in one power system at an affordable price that will close the power delivery loop in your critical facility. Affordable and reliable operation of PCC ensures that power is distributed properly to each piece of your important equipment and you get maximum safety standards. 30 Applications • Computer rooms • LANS/WANS • Communications facilities • Office areas • Medical imaging suits • Grouped workstations • Process control rooms • High-tech manufacturing power sites. Features • Computer-Grade grounding • Handles non linear loads • Online communication tools • Compact single cabinet • Single input cable connections • Easy relocation • Expansion capabilities for future requirement • Onsite power monitoring • Secure distribution and circuit identification • Central monitoring interface • Space saving and easy to install • Optional system enhancement system • Circuit identification. Technical Data Precision Power Center Output KVA 50 75 100 125 150 200 225 Input Voltage 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 Input Circuit Breaker (Amps) 100 100 100 150 150 150 200 200 200 250 250 250 300 300 300 400 400 400 400 400 400 Panel Board Poles Std Opt** 24 96 24 96 48 96 48 96 72 96 96 96 96 96 Dimensions (cm) W D H 600 1000 2000 600 1000 2000 600 1000 2000 600 1000 2000 800 1200 2000 800 1200 2000 800 1200 2000 420 520 630 710 860 1045 1110 2.0 2.55 3.3 4.06 4.5 6.0 6.75 Weight Kg Dimensions (cm) Output • KVA : 50-225, 3 phase • Ground : Single point reference on separately derived system • Input : 3 Phase 3-wire plus ground • 380, 400 or 415 volts : 50 Hz • (Transformer less system require 3 phase, 4w & G) • Distribution : Individually protected 125 Amps panel board • with bolt on breaker and flexible output cables • Cooling system : convection / forced • Output : 3-phase, 4-wire plus ground • 220/380,230/400 or 240/415 volts: 50 Hz • Alarm conditions : O/P & under voltages; O/P overload; • neutral and ground over currents; o/p voltage THD; •Transformers over temperature; frequency deviation; • phase sequence error; phase loss; 5 customer specified • alarm conditioning • Monitored parameters : I/P & O/P Voltages; o/p, Neutral & • grounded currents / P voltage THD; K& crest factor; KVA; • KW; PF; % load; KW Hrs; frequency; o/p current THD • Efficiency : 96-98% • Voltage Adjustment : 10% to + 5% of nominal in 2 ½ % • increments 31 Liebert Powersure Panel Transient Voltage Surge Suppressor Liebert Powersure Panel For Unparalleled Protection That Exceeds Industry Standards... Liebert Powersure Panel utilizes Patent pending circuitry to monitor the status of all protection modes, Including neutral to ground. Should protection be unavailable in any mode, the green LED will be out, and the red LED will illuminate and an audible alarm will sound. In addition, high isolation form C dry contacts for remote monitoring provide indication of: suppression system failure, under voltage, and phase or power loss. Liebert Powersure’s patent pending Suppression Integrity monitoring Indicates failure for both shorted or opened suppression components. 32 The Liebert Powersure Panel incorporates proven technology to provide unparalleled protection from transient surges and electrical line noise (ELN). Applications •Telecommunications and broadcasting Voice and data networks as well as television and radio broadcasters rely on high quality power for f lawless transmission. •Industrial electronics Factories require noise free voltage to keep process control machines running at maximum productivity with minimum downtime. •Computer equipment and networks Office, shops, superstores and other retail businesses need clean power to maintain the integrity of computers and data. •Telecommunications switchgear and cellular facilities Reliable power is essential to ensure networks work reliably, 24 hours a day. •Hospitals Closely controlled power is essential in critical areas such as operating theatres and intensive care. Features The Powersure Series At a Glance • Compact module attaches directly to breaker panel • CE marked, complies with EMC and low voltage directives • Patent Pending Powersure Detection Circuitry • Easy, safe, maintenance free operation • Repeatable surge current capability • Can be retrofitted to existing panel boards • High isolation dry contacts for remote monitoring • Designed for maximum safety • 5 Year warranty • Connection means: Parallel connected • Agency listings: UL1449, Ul1283, CSA, CE, BS6651 • Protection modes: All modes standard (L-N, L-G, N-G, L-L); optional-any combination • EMI/RFI Attenuation: 60dB typical • Response time: Less than .5ns • Operating Frequency: 47/63 Hz • Enclosure: Gray Noryl HS-1000, Rated 94-5V, Nema, 12, 4, 4X, IP65, IP66 • Fault Current Rating: 300,000 AIC • Line frequency: 47-63 Hertz • Temperature: -40 to +60 degrees C • Relative humidity: 0 to 95% noncondensing • Altitude: 0 to 5500m • Audible noise: Less than 45 dBa Technical Data Lower Exposure Medium Exposure Connection Type Operating Voltage Range Surge Current Capacity Fault Current Rating ( A/C ) Dimensions Parallel -15% 25kA, 50kA or 100kA 14kA/C 4.72”x4.72”x2.36” Operating Frequency Range Capacity EMI/RFI Attenuation Response Time Dry Contract rating Operating Temperature Operating Humidity Status Indication Certifications 47…63 Hz Continuous 40 dB typical <0.5 nanoseconds 125 VAC, 8.0A, 1.0pf -40oC to +50oC 0% to 95% LED, Dry Contacts UL 1449, CUL (CE-optional) Parallel -15% 100kA or 160kA 65kA/C (160 kA units) 8”x6”x4” (100 kA units) 6”x4”x3” 47…63 Hz Continuous 40 dB typical <0.5 nanoseconds 125 VAC, 8.0A, 1.0pf -40oC to +50oC 0% to 95% LEDs, Dry Contacts UL 1449, CUL Low Exposure Medium Exposure 400 Volts all modes 800 Volts all modes 1500 Volts all modes 400 Volts all modes 800 Volts all modes 1500 Volts all modes 120 Volt systems 208 through 277 Volt systems 480 Volt systems 33 ASCO Switch Designed To Minimize Downtime On Critical Systems ASCO Switches are the standard of the industry. High speed transfer of loads between alternate sources of power, regardless of ampacity size, is achieved by a reliable, Field proven solenoid operating mechanism. When combined with a programmable microprocessor controller with keypad and LCD display, they offer the most advanced method of transferring all types of loads, such as motors, electronic drives, UPSs and microprocessor based systems. 34 ASCO 7000 Series 7000 Series Power Transfer Switches are available open or enclosed, in ampacity sizes from 30 through 4000 amperes with the largest selection of optional accessories offered anywhere. All switching Configurations are available with an integrally mounted bypassisolation switch and/ or rated for use in service entrance applications . Applications •Healthcare Facilities •Commercial Buildings / Industrial Buildings •Web Hosting, Internet Data Centers •Telecom Central Offices •Process Manufacturing / Wafer Fabrication Plants / Distributed Power / Load Management ASCO Series 300 The ASCO Series 300 was designed for one purpose— to automatically transfer critical loads in the event of a power outage. The rugged construction and proven performance of the ASCO Series 300 assure the user of many years of complete reliability. The Series 300 is even designed to handle the extraordinary demands placed on the switch when starting or restarting stalled motors and switching high inrush loads. Applications •Healthcare Facilities •Commercial Buildings / Industrial Buildings •Web Hosting, Internet Data Centers •Telecom Central Offices Features •The Series 300 is listed to UL 1008 standard for Transfer Switch Equipment and CSA standard C22.2 for automatic transfer switches. •Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles 700, 701 and 702. •30 through 3000 amps in a compact design, Available to 600 VAC, single or three phase. of loads, such as motors, •Rated up to 600 VAC, 30 through 4000 amperes. •True double- throw operation: The single solenoid design is inherently locked and prevents contacts from stopping between sources or from being in contact with both sources at the same time. •High withstand and close- on ratings •There’s no danger of the Series 300 ATS transferring loads to a dead source because the unique ASCO singlesolenoid operator derives power to operate from the source to which the load is being transferred. •Solid, switched, or overlapping neutral conductor options. •Easy- to- read flush- mounted control and display panel provides LED indicators for switch position and source availability. •It also includes test and time- delay bypass switches as standard features. •Standard engine exerciser for weekly automatic testing of engine generator set with or without load. •Adjustable time- delay feature •Supplied with solid neutral termination. •Standard ground conductor connections. •Optional switched neutral pole available. •Accessory kits available. •Meets IEC 60947-6-1 35 Emerson Network Power Is the One Company That Can Provide A Complete Range Of Power Protection Solutions Designed For Any Facility And Any Need Poor power can affect every aspect of your critical operations. Critical equipment and processes throughout your operations can be affected by poor power quality, outages and other related problems. Without Proper Power, Vital Processes Just Cannot Function Important computing, communications and industrial process control functions all depend on clean, continuous power to maintain these operations. From a single desktop PC to a large data center, power quality is the common denominator that must be maintained. Differing Needs Require Different Solutions Different parts of your operation have different needs for power. Depending on the nature of the operation, power needs can range from simple surge protection all the way up to redundant UPS systems and power feeds with backup generating capabilities. Threats To Your System’s Availability Are Around Every Corner There are a number of points within a critical facility where power troubles can develop. Adding to this dilemma is that operations in one part of your facility can adversely affect the power in another area of the building. Your productivity depends on critical electronic systems – can you depend on your power to keep them operating properly? 36 A Power Protection Solution For Every Need Computer Rooms Emerson Network Power offers the full range of UPS, distribution systems and other power protection equipment to meet the needs of the largest data centers and networking facilities. Telecommunications Rooms Emerson Network Power can provide a reliable flow of both AC and DC power for telephone switching systems and other communications equipment. Equipment Rack Enclosures These densely-packed equipment bays, housing servers or other essential communications devices require UPS back-up plus distribution to get uninterrupted, conditioned power to each and every component in the rack. Office Locations With many mission-critical computing systems located right in the office space, there is a need for UPS protection that can be placed nearby. Liebert offers a number of power systems that are especially designed for use in business and office environments. Process Control Rooms Emerson Network Power’s Liebert UPS, surge protection and power distribution are all key to maintaining the proper operation of process control and other manufacturing systems that utilize microprocessor and computer control. Remote Facilities Emerson Network Power’s High-reliability Liebert UPS systems and DC power equipment are critical to maintaining operations in telecommunications shelters and other unmanned structures. 37 Our End to End Solutions 38 End to End System Solutions With Emerson Network Power Power Is Just Part of The Reliability Story Liebert Also Offers A Full Range Of Heat Removal Solutions In addition to proper power, sensitive electronic computer and communications systems also require the correct environment in order to function reliably. Because this equipment produces heat, it is absolutely necessary to control and maintain the temperature and humidity levels where it is located in order to assure continuous operation. The Widest Range Of Products Gives You An Infinite Range Of Solutions As network equipment gets smaller and packed tighter, it creates unprecedented heat densities that can result in thermal shutdown or total component failure. Precision air conditioning, specialized enclosures and rugged remote protection can assure network uptime against this threat. From high-capacity units to compact above-ceiling systems there is a Liebert system designed to cool and protect your critical computing systems. We make the industry’s widest range of precision environmental control, including air conditioners, fluid chillers and heat rejection systems in capacities from one to more than 65 tons. These systems are available with a choice of cooling methods, including chilled water, air cooled and glycol cooled models, as well as ultra energy efficient GLYCOOL™ and Dual-Cool configurations. We also offer specialized systems, including exterior mounted air-conditioning for telecommunications enclosures, supplemental cooling for high-density electronic applications. 39 Emerson Network Power Global Services FACTORY TRAINED You can be sure that the only people who deal with your Critical Air Equipment will be 100% Factory Trained Emerson Service Experts ORIGINAL PARTS You can be sure that the parts you will receive from our 100% Emerson Service Experts are 100% Original Parts. With our multi-tiered parts availability program, you are ensured that parts will be made available to you when and where you need them. VERSION CONTROL You are assured of 100% Version Control so that your critical business systems won’t have to experience downtime due to incompatibility. SUPPORT NETWORK We not only help you develop you Environmental Control System, but our 100% Emerson Service Experts also offer a Full Support Network so that your critical systems have a 100% Safety Net every step of the way. QUALITY RESPONSE We know it is important to get to your critical systems on time. With our 100% Emerson Service Experts you don’t just get prompt service; you also get 100% Quality Response. This means no useless tinkering, no wasted time-- just Quality Service, straight away. 100% Emerson Service Experts. Would you settle for anything less? 24 Our Portfolio Shapes Our Solutions Our Capability Literally Extends From “Grid to Chip”, Offering The Broadest Range of Solutions To The Market. Emerson Network Power offers: • DC Power Systems (Small, Medium, and Large Systems) • Uninterruptible Power Systems (from 500VA to 1000 kVA) • Precision Air Conditioning for Computer Rooms • Automatic Transfer Switches Medium and Low Voltage • Static Switches • Shelter Air Conditioning for Telecommunications • Specialized Enclosures to protect Critical Network Equipment • Surge Suppression and Filtering • Site Monitoring Equipment • All Operating System associated Software • Emerson Network Power Global Services (24X7X365 support for all our customers) 41 Emerson Network Power 1050, Dearborn Drive, P. O. Box: 29186 Columbus, Ohio - 43229 Tel.: 800.877.9222 (US & Canada Only) Tel.: 614.888.0246 (Outside US) Fax: 614.841.6022 Country Office Emerson Network Power (India) Private Ltd. Plot No. C-20, Road No. 19, Wagle Estate, Thane (w), Maharashtra - 400 604. India. Tel.: 91-22-67208000 Fax: 91-22-25828358 Voice of Customers UPS Awards 2006-07 for Product Line & Customer Service Awards in IT, Telecom, Large Enterprise & Hospitals and Customer Service Leadership Award in BFSI 2007 City Offices West Zone Ghatkopar Pune Baroda Nagpur Indore Ahmedabad Vikhroli East Zone Kolkata Jamshedpur Guwahati Bhubaneshwar R : 022-67208800/67209000 : 020-66235000 : 0265-2314296/2330383 : 0712-5634997 : 0731-4023806 : 079-27560230/40 : 022-40780303 : 033-40023100 : 0657-2227678 : 0361-2734486 : 0674-2586003/3299872 North Zone New Delhi Chandigarh Lucknow Gurgaon Jaipur : 011-28753214/0774/2218 : 0172-5077531 : 0522-2237174 : 012-4470015/16/17 : 0141-4024774 Best IT Hardware Company Maharashtra IT Award 2006-07 South Zone Bangalore : 080-41135670/770/870 Secunderabad : 040- 27806771/772 Cochin : 0484-2341985/86 Chennai : 044-28151063/28152596 Vishakapatnam : 0891-2505540/41/42 Coimbatore : 0422-4387625 www.emersonnetworkpower.co.in Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2008 Emerson Electric Co.