POCKET GUIDE Rheem-Ruud Commercial water heaters • Tanktype Gas & Electric • Hot Water Supply Heaters • Indirect • Storage Tanks • Technical Service ...................................800-HEATER3 • U.S. Customer Service ............................800-621-5622 • U.S. Fax ...................................................800-535-9538 • Canada Customer Service ......................800-268-6966 • Canada Fax..............................................800-200-5393 • Website ........................................................rheem.com In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice. Rheem Water Heating and Heating & Cooling Products 101 Bell Road • Montgomery, AL 36117-4305 www.rheem.com Rheem manufactures residential and commercial heating & cooling and water heating products. Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 • Brampton, Ontario, L6Y 0P5 Not all models are available in Canada. Printed in U.S.A. 03/10 WP Form No. RR105-2 Rev. 27 Commercial water heaters from Rheem-Ruud TABLE OF CONTENTS COMMERCIAL GAS WATER HEATERS SPIDERfire Models GHE100-130(A) thru GHE100-350(A)............. AdvantagePlus Models HE45-100 thru HE119-199 ........................ Universal Models G50-98 thru G100-400(A) ................................... Universal Low NOx Models GN75-125 thru GN100-400(A)............ Xtreme Models GX90-550(A) thru GX90-715(A)............................. VentMaster Power Direct Vent Models GP100-150 & GP100-250(A) Induced Draft GD100-250(A) thru GD100-360(A)........................... Medium Duty Models G60-50 thru G100-80.................................... PowerVent GPV75-75E ................................................................... Power Venter Kits ............................................................................ 2-3 4-5 6-7 8-9 10-11 12-13 14-15 16-17 18-19 20-21 COMMERCIAL HOT WATER SUPPLY HEATERS With Pump GBBP136 thru GBCP1826............................................ 22-23 Without Pump GBB136 thru GBC1826 ........................................... 22-23 COMMERCIAL ELECTRIC WATER HEATERS Large Volume EVRO, EVS and EHSO Models ............................... Heavy Duty ES50, ES85, ES120, E50(A), E85(A) and E120(A)..... PowerPack Heavy Duty E12A, E20A, E30A and E40A................... Eclipse ............................................................................................. Booster E10 ..................................................................................... Light Duty Models ELD30 thru ELD120........................................... Light Duty Models ELDS30 thru ELDS52........................................ Point-of-Use EGSP2 thru EGSP30 ................................................. 24-25 26-27 28-29 30-31 32-33 34-35 34-35 36-37 INDIRECT WATER HEATERS ........................................................ 38-39 COMMERCIAL STORAGE TANkS ST80(A), ST120(A) and ST175(A) .................................................. 40-41 Large Volume Storage Tanks........................................................... 42-43 CertiSpec 3.2 on Internet Download ............................................ 44-45 COMPETITOR CROSS REFERENCE INDEX Dimensions reflect models built prior to 1/20/04. A.O. SMITH Gas – Tank Type BTR & BTH (Cyclone).......................................... 46-47 Gas – Hot Water Supply Heaters BC, HW & DW............................ 48-49 Storage Tank Systems TJ, TJV........................................................ 49 Electric – Light/Heavy Duty & Boosters DEL, DEN, DRE, DVE, CMC, SU ................................................ 50-51 AMERICAN Gas – Tank Type PVCG32, CG32, DCG32, PVDCG32, DCG31.... 52-53 Electric – Light/Heavy Duty LDCE, ITCE,STCE, AITCE, ASTCE.... 54-55 Storage Tank Systems CST, ACST.................................................. 55 BRADFORD WHITE Gas – Tank Type .............................................................................. 56-57 Gas – Hot Water Supply Heaters L-I-T1.......................................... 58-59 Storage Tank Systems M-3-ST........................................................ 59 Electric – Light/Heavy Duty Booster M-II-SF-CF, LI............................................................................... 60-61 LOCHINVAR Gas – Tank Type CNR, CNA ........................................................... 62-63 Gas – Hot Water Supply Heaters CPN, RWN, CWN ........................................................................ 64-65 Storage Tank Systems RJS, RJA .................................................... 65 Electric – Light/Heavy Duty & Boosters ETX, ETW, ESX, ETX, SB, HS, HC............................................. 66-67 STATE Gas – Tank Type SBT, SBF ............................................................. 68-69 Electric – Light /Heavy Duty CPE, SB6 ........................................... 70-71 Storage Tank Systems PV ............................................................... 71 2 SPIDERfire® Sealed Combustion Gas-Fired 130,000 – 350,000 BTU/HR. INTAKE SPIDERfire Features: (On Selected Models) (With Optional Kit) • • • • • • • • • • • Maximum thermal efficiency of 95% dramatically reduces operating costs No chimney required; power or direct vent using plastic pipe Low NOx emissions. Meets SCAQMD Rule 1146.2 Corrosion resistant, high efficiency 3-pass heat exchanger Self-diagnostic LCD electronic control Direct spark ignition 185° F maximum temperature setting Zero clearance to all combustible surfaces Full flow drain valve Front and back water connectioins Factory installed AGA/ASME rated T&P relief valve EXHAUST TEMP SENSOR T&P 31° DRAIN VALVE 31° 42° 41° TOP VIEW GAS INLET EXHAUST AIR INTAKE HOT OUT REAR T&P HOT OUT FRONT A C F H COLD IN FRONT G E HAND HOLE CLEANOUT DRAIN VALVE COLD IN REAR D B LEFT SIDE RECOVERy CAPACITIES MODEL NuMBER FRONT RIGHT SIDE REAR DIMENSIONAL INFORMATION All dimensions shown in inches INPuT (BTu/HR) THERMAL NAT. & LP EFFICIENCy uNITS TEMP. RISE – GPH 40°F 100°F 140°F A B C D E F G H VENT WATER CONNECTS INLET OuTLET APPROX. SHIP. WT. (LB)* GHE100-130(A) 130,000 95% GPH 374 150 107 78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 2, 3, 4 2" NPT 2" NPT 785 GHE100-160(A) 160,000 95% GPH 461 184 132 78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 2, 3, 4 2" NPT 2" NPT 785 GHE100-200(A) 199,000 95% GPH 573 229 164 78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 2, 3, 4 2" NPT 2" NPT 785 GHE100-250(A) 250,000 93% GPH 705 282 201 78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 3, 4 2" NPT 2" NPT 825 GHE100-300(A) 300,000 93% GPH 845 338 242 78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 3, 4 2" NPT 2" NPT 825 GHE100-350(A) 350,000 92% GPH 976 390 279 78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 3, 4 2" NPT 2" NPT 825 *Weights listed are for non-ASME. Add 35 lbs. for ASME models. 130,000 - 199,000 BTU models are certified to be installed with 2" venting. All models require a 120V power source. See use and care manual for venting details. †Overall width is 27-5/16" due to exhaust cover. 0" CLEARANCE TO COMBUSTIBLES MODELS WITH INPUTS OF 130,000 BTU THRU 199,000 BTU ARE CERTIFIED TO VENT WITH 2" SCHEDULE 40 PVC, CPVC OR ABS PIPE (FOR CANADIAN INSTALLATIONS, PLEASE USE ULC-S636 PVC AND CPVC PIPE.) 3 4 AdvantagePlus™ Sealed Combustion Gas 100,000 – 199,000 BTU/HR. AdvantagePlus Features: • 316L stainless steel tank construction (requires no anode rods). • No chimney required; direct vent using plastic pipe. • Thermal efficiency of 95% dramatically reduces operating costs. • 85 equivalent feet of vent length. • Low NOx emissions. Meets SCAQMD Rule 1146.2. • High impact plastic jacket eliminates dents. • 2” of non-CFC, polyurethane foam insulation. • Less than 1/2 degree per hour heat loss (R17). • Corrosion resistant, high efficiency 90/10 cupronickel heat exchanger. • Self-diagnostic electronic control with digital readout for water temperature, set point and differential. • Removable front cover allows easy access to equipment (24" service clearance recommended). • Temperature range from 70°F to 160°F (maximum temperature setting of 180°F available on HE55-160 and HE55-199 booster models only). • Zero clearance to all combustible surfaces. • Factory installed AGA/ASME rated T&P relief valve. • Booster installation kit provided with HE55-160 and HE55-199 booster models. CAP. GALS. 55 55 80 119 55 80 119 55 80 119 INPUT (BTU/HR.) NAT. & LP 100,000 130,000 130,000 130,000 160,000 160,000 160,000 199,000 199,000 199,000 THERMAL EFFICIENCY 95% 95% 95% 95% 95% 95% 95% 95% 95% 95% 40° 288 374 374 374 461 461 461 573 573 573 TEMPERATURE RISE – DEGREES F – GALLONS PER HOUR 50° 60° 70° 80° 90° 100° 110° 120° 130° 230 192 165 144 128 115 105 96 N/A 299 249 214 187 166 150 136 125 N/A 299 249 214 187 166 150 136 125 N/A 299 249 214 187 166 150 136 125 N/A 368 307 263 230 205 184 167 154 142 368 307 263 230 205 184 167 154 N/A 368 307 263 230 205 184 167 154 N/A 458 382 327 286 255 229 208 191 176 458 382 327 286 255 229 208 191 N/A 458 382 327 286 255 229 208 191 N/A 140° N/A N/A N/A N/A 132 N/A N/A 164 N/A N/A The recovery rate is based on recovery efficiencies obtained in a UL certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures and exceed the thermal efficiency and standby loss requirements of ASHRAE (part of the Federally mandated Energy Policy Act - EPACT). These models also exceed the energy efficiency codes of all states including the California Energy Commission (CEC). All models are North Carolina Code compliant. DIMENSIONAL INFORMATION MODEL NUMBER HE55-100* HE55-130* HE80-130* HE119-130* HE55-160 HE80-160 HE119-160 HE55-199 HE80-199 HE119-199 A B C D E 52 52 72 73 52 72 73 52 72 73 23-1/2 23-1/2 23-1/2 27 23-1/2 23-1/2 27 23-1/2 23-1/2 27 32 32 32 36 32 32 36 32 32 36 45 45 65 66-3/4 45 65 66-3/4 45 65 66-3/4 5 5 5 6-3/4 5 5 6-3/4 5 5 6-3/4 (All dimensions shown in inches) F 25-1/4 25-1/4 25-1/4 28-7/8 25-1/4 25-1/4 28-7/8 25-1/4 25-1/4 28-7/8 VENT 2* 2* 2* 2* 3 3 3 3 3 3 Hot Out Gas Inlet AD Electrical Connection F Cold In E 3.75” C Condensate Connection (All models require 120V power source.) RECOVERY CAPACITIES MODEL NUMBER HE55-100* HE55-130* HE80-130* HE119-130* HE55-160 HE80-160 HE119-160 HE55-199 HE80-199 HE119-199 B WATER CONNECTIONS INLET OUTLET 1 1 1 1 1-1/2 1-1/2 1-1/2 1-1/2 1 1 1-1/2 1-1/2 1-1/2 1-1/2 1 1 1-1/2 1-1/2 1-1/2 1-1/2 APPROX. SHIPPING WEIGHT (LBS.) 175 lbs. 175 lbs. 235 lbs. 405 lbs. 175 lbs. 235 lbs. 405 lbs. 175 lbs. 235 lbs. 405 lbs. CLEARANCE TO COMBUSTIBLES 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The HE55-160 and HE55-199 Booster models are the only models equipped with a 180°F thermostat. Models with 180°F thermostats come standard with the Booster Installation kit which includes all necessary components for an approved installation. BOOSTER INSTALLATION kIT INCLUDES: • Nibco Tee – 1" x 1" x 1/2" (2 pieces) • Female Adapter – 1" (2 pieces) • Dial Thermometer (2 pieces) • Expansion Tank – 4-1/2 gallon • Grundfos 3 Speed Pump with Check Valve • Nibco 1.2" x 12" Fitting Air Chamber • Vacuum Relief Valve • Pressure Gauge – 0-200 PSI • Nibco Tee 712R – 1" x 1" x 3/4" (2 pieces) • Nibco Tee 714RR – 1" x 1/2" x 1" • Nibco Tee – 1" x 1/2" x 1" Copper • Reducing Coupling • Pressure Reducing Valve • Nibco Male Adapter – 1" *The models with inputs of 100,000 kBtu and 130,000 kBtu are certified to vent with 2" Schedule 40 PVC, CPVC or ABS pipe. (For Canadian models, vent with 2" ULC-S636 PVC or CPVC pipe) Use HEC prefix for Canadian models. 5 6 Universal™ Heavy Duty Gas 98,000 – 400,000 BTU/HR. Universal Features: • Factory installed AGA/ASME rated T&P relief valve • Handhole cleanout • Stainless steel burners • 180° max operating temperature • LED diagnostics on all damper assemblies for easier service • Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) • Manual reset high limit (ASME models) • Low NOx models available • Small jacket diameters • Short floor-to-vent heights • Multiple water connections • System Sentinel™ LED diagnostic system Standard Features: (On Selected Models) (With Optional Leg Kit) • 3 year limited tank warranty • Patented multiflue design • Low profile automatic flue damper • Spark-to-pilot ignition system • Full port, full flow brass drain valve GAL. INPUT BTU/HR. CAP. NATURAL & L.P. G50-98 G75-125 G82-156 G76-180 G37-200 G76-200 G91-200 G100-200(A) G72-250(A) G100-250(A) G100-270(A) G72-300(A) G85-300(A) G100-310(A) G65-360(A) G65-400(A) G85-400(A) G100-400(A) 50 75 82 76 35 76 91 100 72 100 100 72 85 100 65 65 85 100 98,000 125,000 156,000 180,000 199,900 199,900 199,900 199,900 250,000 250,000 270,000 300,000 300,000 310,000 360,000 399,900 399,900 399,900 OUTLET REAR SIDE INLET TOP OUTLET FRONT SIDE T&P C INLET FRONT SIDE F B A SYSTEM SENTINEL G INLET REAR SIDE D 7" (178mm) DIMENSIONAL INFORMATION (All dimensions shown in inches) RECOVERY CAPACITIES MODEL NUMBER H E OUTLET TOP THERMAL EFFICIENCY 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% TEMP. RISE - GPH 40° 100° 140° 238 95 68 303 121 87 378 151 108 436 175 125 485 194 138 485 194 138 485 194 138 485 194 138 606 242 173 606 242 173 654 262 187 727 291 208 727 291 208 752 301 215 873 349 249 969 388 277 969 388 277 969 388 277 A B C D E F G H 62-3/4 65-1/2 68-13/16 68-13/16 49-1/4 68-13/16 76-5/16 73-1/16 71-1/16 73-1/4 73-7/8 71 78-7/16 75 70-11/16 70-11/16 78-13/16 76 57-1/8 61 64 64 43-3/8 64 71-13/16 66-1/8 64-1/2 66-1/8 66-1/8 64-1/2 72-5/16 68-1/2 64-1/2 64-1/2 72-5/16 68-1/2 22-1/2 26-1/4 26-1/4 26-1/4 26-1/4 26-1/4 26-1/4 30-1/4 26-1/4 30-1/4 30-1/4 26-1/4 26-1/4 30-1/4 26-1/4 26-1/4 26-1/4 30-1/4 22-5/8 25 25 25 25 25 30-5/8 23-1/4 25 23-1/4 23-1/4 25 30-5/8 32-1/4 25 25 30-5/8 32-1/4 5 5 6 6 6 6 6 6 6 8 8 8 8 7 8 8 10 8 50-1/2 56 58-5/8 58-5/8 37-5/8 58-5/8 66-3/8 57-1/2 58-5/8 57-1/2 57-1/2 58-5/8 66-3/8 61-3/4 58-5/8 58-5/8 66-3/8 61-3/4 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1* 15 20 20 20 20 20 20 23 20 23 23 20 20 23 N/A N/A 20 23 WATER CONNECTIONS TOP FRONT REAR IN/OUT SIDE SIDE 1 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 1-1/2 2 2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 N/A 1-1/2 1-1/2 N/A 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 APPROX. SHIPPING WEIGHT (LBS.) STANDARD ASME 270 N/A 480 N/A 490 N/A 540 N/A 405 N/A 540 N/A 600 N/A 780 835 590 630 795 835 805 845 590 630 640 680 770 810 640 680 640 680 640 680 770 810 CLEARANCES TO COMBUSTIBLES SIDE REAR TOP 2" 2" 12" 2" 2" 12" 2" 2" 12" 2" 2" 12" 2" 2" 12" 2" 2" 12" 2" 2" 12" 2" 4" 12" 6" 6" 12" 2" 4" 12" 2" 4" 12" 6" 6" 12" 6" 6" 12" 4" 4" 12" 6" 6" 12" 6" 6" 12" 6" 6" 12" 4" 4" 12" Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Thermal Efficiency in accordance with ANSI Z21.10.3 labeling requirements. “(A)” Indicates Available ASME Model. *3/4" for L.P. Models. Increase Height 3-5/8" for NSF Models. All Models Require a 120V Power Source. These models have been tested according to ANSI test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). All models are North Carolina Code compliant. 7 8 Universal™ Heavy Duty Gas Low NOx 125,000 – 400,000 BTU/HR. Universal Features: • Small jacket diameters • Short floor-to-vent heights • Multiple water connections • System Sentinel™ LED diagnostic system (On Selected Models) Standard Features: • 3 year limited tank warranty • Patented multiflue design • Low profile automatic flue damper • Spark-to-pilot ignition system • Full port, full flow brass drain valve • Factory installed AGA/ASME rated T&P relief valve • Handhole cleanout • 180° max operating temperature • Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) • Manual reset high limit (ASME models) • Low NOx Burner – The Power Assist enclosed burner design incorporates stainless steel multi-port burner tubes for long term Low NOx compliant performance. A sight glass allows for burner observation and the entire assembly is easily removable. A blower guard is provided against post-installation damage. The entire design is highly resistant to the effects of negative air pressures common to modern commercial buildings. OUTLET TOP OUTLET REAR SIDE H E OUTLET FRONT SIDE INLET TOP T&P C INLET FRONT SIDE F B A SYSTEM SENTINEL G INLET REAR SIDE D 7" (178mm) DIMENSIONS (Inches) A MODEL NUMBER GN75-125 65-1/2 GN82-156 68-13/16 GN37-200 49-1/4 GN76-200 68-13/16 GN91-200 76-5/16 GN100-200(A) 73-1/16 GN72-250(A) 71-1/16 GN100-250(A) 73-1/4 GN100-270(A) 73-7/8 GN65-360(A) 70-11/16 GN100-400(A) 76 B61 64 43-3/8 64 71-13/16 66-1/8 64-1/2 66-1/8 66-1/8 64-1/2 68-1/2 C 26-1/4 26-1/4 26-1/4 26-1/4 26-1/4 30-1/4 26-1/4 30-1/4 30-1/4 26-1/4 30-1/4 D E5 F G H20 25 56 3/4 25 25 25 30-5/8 23-1/4 25 23-1/4 23-1/4 25 32-1/4 6 6 6 6 6 6 6 6 8 8 58-5/8 37-5/8 58-5/8 66-3/8 57-1/2 58-5/8 57-1/2 57-1/2 58-5/8 61-3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 20 20 20 20 23 20 23 23 N/A 23 WATER CONNECTIONS TOP FRONT REAR IN/OUT SIDE SIDE 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 1-1/2 2 2 N/A 1-1/2 1-1/2 1-1/2 2 2 APPROXIMATE SHIPPING WEIGHT STD. ASME 480 lbs. N/A 490 lbs. N/A 405 lbs. N/A 540 lbs. N/A 600 lbs. N/A 780 lbs. 835 lbs. 590 lbs. 630 lbs. 795 lbs. 835 lbs. 805 lbs. 845 lbs. 640 lbs. 680 lbs. 770 lbs. 810 lbs. All Models Require a 120V /1.5 Amp Power Source. (A) Suffix Indicates ASME Tank Construction Available. 9 10 Xtreme™ High-Input Gas 550,000 – 715,000 BTU/HR. Xtreme Features: C ® US LISTED • Small jacket diameters • Short floor-to-vent heights • Multiple water connections • System Sentinel™ LED diagnostic system Standard Features: • 3 year limited tank warranty • Patented multiflue design • Low profile automatic flue damper • Specialized burner assembly • Spark-to-pilot ignition system • Full port, full flow brass drain valve RECOVERY CAPACITIES MODEL NUMBER GX90-550(A) GX90-640(A) GX90-715(A) GX90-500(A) LP GX90-600(A) LP GX90-680(A) LP • Factory installed AGA/ASME rated T&P relief valve • Handhole cleanout • Round premix stainless steel burners • Manual reset high limit • Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) • Low NOx models: GX90-550(A) GX90-640(A) C E OUTLET FRONT SIDE T&P F BA INLET FRONT SIDE SYSTEM SENTINEL D G Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises. INPUT BTU/HR. NATURAL & L.P. 550,000 NAT 640,000 NAT 715,000 NAT 500,000 LP 600,000 LP 680,000 LP THERMAL EFFICIENCY 80% 80% 80% 80% 80% 80% 40°F 1333 1551 1733 1212 1455 1649 50°F 60°F 1067 889 1241 1034 1387 1156 970 808 1164 970 1319 1099 70°F 762 887 991 693 831 942 80°F 90°F 100°F 110°F 667 593 533 485 776 690 621 564 867 770 693 630 606 539 485 441 727 647 582 529 824 733 659 599 120°F 444 517 578 404 485 550 130°F 410 477 533 373 448 507 140°F 381 443 495 346 416 471 Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model. DIMENSIONAL INFORMATION MODEL NUMBER GX90-550(A) GX90-640(A) GX90-715(A) GX90-500(A) LP GX90-600(A) LP GX90-680(A) LP A 74.5 74.5 74.5 74.5 74.5 74.5 (All dimensions shown in inches) B 68 C D E 30 25 10 F59 G1 68 68 68 68 68 30 30 30 30 30 59 59 59 59 59 25 25 25 25 25 10 10 10 10 10 All Models Require a 120V Power Source. (A) Suffix Indicates ASME Tank Construction Available. 1 1 1 1 1 WATER CONNECTIONS FRONT REAR SIDE SIDE 2 2 2 2 2 2 2 2 2 2 2 2 APPROXIMATE SHIPPING WEIGHT STD. ASME 905 945 905 945 905 945 905 945 905 945 905 945 11 12 VentMaster™ Power Direct Vent Gas 150,000 – 250,000 BTU/HR. Standard Features: • Non-condensing design • Integral automatic blower • Patented multi-flue tank design • Spark-to-pilot ignition system • System Sentinel™ LED diagnostic system • Full port, full flow brass drain valve • No masonry or metal vent chimney required • Installs with 3" or 4" schedule 40 PVC pipe • Vents up to 50 feet E C INPUT BTU/HR. 150,000 199,900 250,000 40°F 364 485 606 50°F 291 388 485 60°F 242 323 404 70°F 208 277 346 80°F 182 242 303 GPH 90°F 161 215 269 A D RECOVERY CAPACITIES (80% thermal efficiency) MODEL NUMBER GP100-150 GP100-200 GP100-250(A) F B CLEARANCE TO COMBUSTIBLES (inches) 100°F 110°F 120°F 130°F 140°F 146 132 122 112 104 194 176 162 149 138 242 220 202 186 173 MODEL NUMBER SIDE REAR TOP 6" 18" GP100-150 2" GP100-200 51mm GP100-250(A) 153mm 459mm FIRST TIME DELIVERY (Includes useable storage and recovery for indicated times.) MODEL NUMBER GP100-150 GP100-200 GP100-250(A) TANk CAP. GALLONS 100 100 100 INPUT BTU/HR. 150,000 199,900 250,000 5 Minutes 82 86 90 10 Minutes 94 102 110 TEMP. RISE AT 100°F IN GALLONS 15 20 30 Minutes Minutes Minutes 106 119 143 118 135 167 131 151 191 45 Minutes 179 215 252 60 Minutes 216 264 312 Minutes to Rec. Contents 40 31 25 DIMENSIONS (Inches) MODEL NUMBER GP100-150 GP100-200 GP100-250(A) A B C D E F G 81-3/4 81-3/4 81-3/4 68-1/4 68-1/4 68-1/4 30-1/4 30-1/4 30-1/4 24-3/4 24-3/4 24-3/4 3 3 4 59 59 59 3/4 3/4 3/4 WATER CONNECTIONS FRONT REAR IN/OUT SIDE 2 2 2 2 2 2 APPROXIMATE SHIPPING WEIGHT 860 lbs. 860 lbs. 860 lbs. Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model. 13 14 Induced Draft Gas 250,000 – 360,000 BTU/HR. Universal Features: • 6" Category I appliance – allows for easy upgrade or retrofit of existing applications • Spark-to-pilot ignition system • Full port, full flow brass drain valve • Small jacket diameters • Short floor-to-vent heights • Multiple water connections • System Sentinel™ LED diagnostic system OUTLET REAR SIDE Standard Features: (On Selected Models) (With Optional Leg Kit) H E OUTLET TOP INLET TOP OUTLET FRONT SIDE T&P C • 3 year limited tank warranty • Patented multiflue design • Factory installed draft inducer – provides an induced draft allowing higher BTU's to be vented through a 6" vent INLET FRONT SIDE F B A SYSTEM SENTINEL G INLET REAR SIDE D 7" (178mm) RECOVERY CAPACITIES MODEL NUMBER Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises. INPUT BTU/HR. NATURAL & L.P. THERMAL EFFICIENCY UNITS 40°F 50°F 60°F 70°F 250,000 270,000 310,000 360,000 80% 80% 80% 80% GPH GPH GPH GPH 606 655 752 873 485 524 601 698 404 436 501 582 346 374 429 499 GD100-250(A) GD100-270(A) GD100-310(A) GD100-360(A) 80°F 90°F 100°F 110°F 120°F 130°F 140°F 303 327 376 436 269 291 334 388 242 262 301 349 220 238 273 317 202 218 251 291 186 201 231 269 173 187 215 249 Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model. DIMENSIONAL INFORMATION All Dimensions Shown in English. MODEL NUMBER UNITS A B GD100-250(A) GD100-270(A) GD100-310(A) GD100-360(A) inches inches inches inches 73-1/2 73-1/2 73-1/2 73-1/2 66-3/4 66-3/4 66-3/4 66-3/4 C D E F G H 30-1/4 30-1/4 30-1/4 30-1/4 23-1/4 23-1/4 23-1/4 23-1/4 6 6 6 6 57-1/2 57-1/2 57-1/2 57-1/2 All models require a 120V /3 amp power source. (A) suffix indicates ASME tank construction available. 3/4 3/4 3/4 3/4 23 23 23 23 WATER CONNECTIONS TOP FRONT REAR IN/OUT SIDE SIDE 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 2 2 2 2 2 APPROXIMATE SHIPPING WEIGHT STD. ASME 795 lbs. 795 lbs. 795 lbs. 795 lbs. 835 lbs. 835 lbs. 835 lbs. 835 lbs. 15 16 Medium-Duty Gas 45,000 – 80,000 BTU/HR. Standard Features: • Small jacket diameters • Short floor-to-vent heights • 3 year limited tank warranty • Rigid foam insulation • Heavy duty anode rod • Factory installed AGA/ASME rated T&P relief valve • Brass drain valve • Gas control system • Certified for a 150 PSI maximum working pressure • Low NOx models available – N Models (with optional leg kit) F F E E C A B 3/4" T&P 3/4" N.P.T. RELIEF VALVE OPENING HOT & COLD A G B C SIDE TAPS G 1/2" GAS CONNECTION 1/2" D 2" D G50-65, G60-50 & G75-75 G100-80 SIDE TAPS ON 50 & 75 GAL. MODELS ONLY WATER CONNECTIONS ARE 1" NPT G50-65 & G60-50 WATER CONNECTIONSARE 3/4" NPT G75-75 WATER CONNECTIONS ARE 1" NPT RECOVERY CAPACITIES MODEL NUMBER CAP. GALS. INPUT BTU/HR. GAS TYPE G60-50N†* G60-50LP* G50-65N†* G50-65LP* G75-75N-2†* G75-75LP* G100-80 G100-80N† 60 60 48 48 75 75 100 100 Natural LP Natural LP Natural LP Natural Natural 50,000 45,000 65,000 48,000 75,100 65,000 80,000 76,000 TEMPERATURE RISE – DEGREES F – GALLONS PER HOUR 40° 115 104 150 111 182 150 194 184 50° 92 83 120 88 146 120 155 147 60° 77 69 100 74 121 100 129 123 70° 66 59 86 63 104 86 111 105 80° 58 52 75 55 91 75 97 92 90° 51 46 67 49 91 67 86 82 100° 46 41 60 44 73 60 78 74 110° 42 38 54 40 66 54 71 67 120° 38 35 50 37 61 50 65 61 130° 35 32 46 34 56 46 60 57 CLEARANCES TO COMBUSTIBLES MODEL REAR/ NUMBER SIDES FRONT TOP G60-50 1" 3" 2" G50-65 0" 3" 2" G75-75 1" 3" 2" G100-80 1" Alcove 12" Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. N = Low NOx DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL NUMBER G60-50 G50-65 G75-75 G100-80 A 62 62-1/2 64 69-5/8 B 58 58-1/2 60 65-3/4 C 23 21-3/4 26-1/4 28-1/4 D 13-1/4 14 13-1/4 11 E 4 4 4 4 F 8 11 11 15 G 48-1/2 51-3/4 53-1/4 57-13/16 APPROX. SHIPPING WEIGHT (LBS.) 180 180 320 410 NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITH FVIR MODELS Note: Meets 40ng/J Low NOx requirements. *FVIR compliant † 17 18 PowerVent Gas 75,000 BTU/HR. Standard Features: • Uses 3" or 4" schedule 40 PVC, CPVC or ABS pipe • Vents up to 95 feet • Easy to install/maintain blower assembly • Spark-to-pilot ignition system • Low NOx burner • Self-diagnostic thermostat/gas valve • 2" rigid foam insulation • 3 year limited warranty • Factory installed AGA/ASME rated T&P relief valve • Certified for a 150 PSI maximum working pressure • Durable brass drain valve • FVIR compliant POWER VENT ASSEMBLY ANODE ROD G HOT WATER CONNECTION G E COLD WATER CONNECTION T&P FITTING 3/4" N.P.T. C A B F SIDE TAPS 1/2" D DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL NUMBER GPV75-75FV-2 A B C D E F G 72 60-1/8 26-1/4 14-3/4 11 53-1/4 1 APPROX. SHIPPING WEIGHT (LBS.) 330 RECOVERY CAPACITIES MODEL NUMBER GPV75-75FV-2 GPV75-75PFV-2 INPUT BTU/HR. NATURAL & L.P. 75,000 70,000 40° 173 161 TEMPERATURE RISE - DEGREES F - GALLONS PER HOUR 50° 60° 70° 80° 90° 100° 110° 138 115 99 86 77 69 63 129 107 92 81 72 64 59 120° 58 54 19 20 Power Vent kits Gas Construction Features: • Certified for use on natural and propane gas TYPICAL APPLICATION models. • Maximum venting length up to 50 feet equivalent including the vent terminal. • Vent terminal can be installed through combustible • • • Manufactured by Tjernlund Products, Inc., Rheem-Ruud Commercial Gas Water Heater Power Vent Kits are your best choice for new construction, electric-to-gas conversions and renovations. • • • For technical assistance, please call the Tjernlund Help Line at 1-800-255-4208. Model G50-98 G75-125 G82-156 G76-180 G37-200 G76-200 G91-200 G100-200(A) G72-250(A) G100-250(A) G100-270(A) G72-300(A) G85-300(A) G100-310(A) G65-360(A) G65-400(A) G85-400(A) G100-400(A) GD100-250(A) GD100-270(A) GD100-310(A) GD100-360(A) Vent kit PV Kit 4 PV Kit 4 PV Kit 4 PV Kit 4 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 PV Kit 5 Draft Part Hood Vent Vent No. Outlet Size Adapter* AP11646 5" 4" 5" x 4" AP11646 5" 4" 5" x 4" AP11646 6" 4" 6" x 4" AP11646 6" 4" 6" x 4" AP11646 6" 4" Not Req. AP11645 6" 6" Not Req. AP11645 6" 6" Not Req. AP11645 6" 6" Not Req. AP11645 6" 6" Not Req. AP11645 8" 6" 8" x 6" AP11645 8" 6" 8" x 6" AP11645 8" 6" 8" x 6" AP11645 8" 6" 8" x 6" AP11645 7" 6" 7" x 6" AP11645 8" 6" 8" x 6" AP11645 8" 6" 8" x 6" AP11645 10" 6" 10" x 6" AP11645 8" 6" 8" x 6" AP11645 6" 6" Not Req. AP11645 6" 6" Not Req. AP11645 6" 6" Not Req. AP11645 6" 6" Not Req. *Note: Vent Pipe and Vent Adapter are NOT included. Floor or non-combustible surfaces – heat shield is provided. Vent terminal is constructed from heavy-duty corrosion resistant aluminum. Venter can be connected to a vent termination on an exterior wall. Vibration isolators are supplied to provide quiet operation. Safety interlocks standard. Complete with mounting hardware. Venter is pre-wired with 40 feet of #18-4 copper wire (24 volt) to minimize field connections. POWER VENTER (from Tjernlund) VENT TERMINAL Motor Motor Max Height Width Depth Inlet kit# Watts Amps Vent (H) (W) (D) Outlet 4 95 1.26 50 ft 7-7/8" 11" 7" 5 170 1.51 50 ft 9-1/4" 11-5/8" 8-5/8" Exterior Wall kit# A B C Rough in Dimension 4" 4 9" 9-1/2" 7" Sq. 8" Sq. 6" 5 10-1/8" 9-1/2" 8-1/2" Dia. 9" Dia. Note: Max Vent Length based on total length of straight vent pipe plus 10 feet for each 90 degree elbow and 5 feet for each 45 degree elbow. B D H W A Sq. C Power vent kits manufactured by Tjernlund Products, Inc. are tested and certified by CSA for use on these Rheem-Ruud Commercial Gas Heaters. • Not for use with GN, GP, and GX models. 21 22 Hot Water Supply Heaters Gas 136,000 – 1,826,000 BTU/HR. Standard Features: • 82% thermal efficiency • 5 year limited warranty • Indoor and outdoor installations • Meets ASHRAE standards • Natural gas or L.P. • Certified for a 160 PSI maximum working pressure Controls: • Energy saving pump control • Flow switch • Spark-to-pilot ignition system • High limit control • On/Off switch • Flue gas spillage sensor • Flame roll-out sensor Heat Exchanger: • Finned copper tubes • ASME steel tubesheet • Silicon O-rings • 125 PSIG ASME pressure relief valve • Glasslined cast iron headers Gas Control Train: • Manual gas shut-off cock • Main gas pressure regulator • Safety shut-off valve, redundant • Control valve SPECIFICATIONS AND DIMENSIONS MODEL NUMBER Without With Pump Pump STYLE MBTUH PROPANE GAS† MBTUH NATURAL GAS (X 1000) InOutdoor door (indoor) Input Output (outdoor) Input Output DIMENSIONS (INCHES) Temperature Rise – Gallons Per Hour 40°F 100°F 140°F Width Height Overall Jac. Gas Flue Ht. Conn. Dia. GBB136* GBBP136* • • 136.0 112.0 136.0 112.0 330 132 94 141⁄4 45.0 301⁄8 1 GBC186 GBCP186 • • 181.0 148.0 181.0 148.0 445 178 127 181⁄4 40.0 38 3 GBC264 GBCP264 • • 264.0 216.0 264.0 216.0 640 256 183 22 ⁄8 40.0 38 3 GBC331 GBCP331 • • 334.0 274.0 334.0 274.0 822 328 235 253⁄4 40.0 38 3 GBC399 GBCP399 • • 399.0 327.0 399.0 327.0 967 387 276 291⁄4 40.0 38 3 GBC512 GBCP512 • • 511.5 419.4 511.5 419.4 1240 496 354 32 ⁄4 57.0 GBC627 GBCP627 • • 627.0 514.1 627.0 514.1 1520 608 434 371⁄2 GBC726 GBCP726 • • 726.0 595.4 726.0 595.4 1760 704 503 415⁄8 GBC825 GBCP825 • • 825.0 676.5 825.0 676.5 2000 800 571 GBC926 GBCP926 – • – – 926.0 759.3 3345 898 SHIPPING WEIGHT†† Model Size (Indoor) (Outdoor) 136-399 Same as natural gas 512-825 .94 926-1826 .92 Indoor ⁄2 6 195 195 ⁄4 6 191 200 ⁄4 7 214 220 ⁄4 8 234 240 ⁄4 9 253 260 33 1 10 510 535 57.0 33 1 12 520 545 57.0 33 1 12 630 685 453⁄4 57.0 33 1 14 660 720 641 523⁄8 – – 1 – – 790 3 3 GBC962 GBCP962 • – 961.7 788.6 – – 2331 933 665 523⁄8 683⁄4 331⁄2 1 14 760 – GBC1083 GBCP1083 – • – – 1083.0 888.1 2625 1050 750 591⁄4 – – 1 – – 850 GBC1125 GBCP1125 • – 1124.7 922.2 – – 2727 1091 779 59 ⁄4 74 ⁄2 33 ⁄2 1 16 800 – GBC1178 GBCP1178 – • – – 1178.0 966.0 2856 1142 816 635⁄8 – – 1 – – 910 GBC1223 GBCP1223 • – – – 2964 1185 847 63 ⁄8 74 ⁄2 33 ⁄2 1 16 860 – GBC1287 GBCP1287 – • 1287.0 1055.3 3120 1248 891 685⁄8 – – 11⁄4 – – 975 GBC1337 GBCP1337 • – GBC1413 GBCP1413 – • GBC1467 GBCP1467 • – GBC1570 GBCP1570 – • GBC1630 GBCP1630 • – GBC1758 GBCP1758 – • GBC1826 GBCP1826 • – 1222.5 1002.4 – – 1336.6 1096.0 – – 1467.0 1202.9 – – 1630.0 1336.5 – – 1825.6 1496.9 1 5 1 1 1 1 – – 3240 1296 926 685⁄8 761⁄2 331⁄2 11⁄4 18 930 – 1413.0 1158.7 3425 1370 979 747⁄8 – – 11⁄4 – – 1065 – – 3556 1423 1016 747⁄8 761⁄2 331⁄2 11⁄4 18 1000 – 1570.0 1287.4 3806 1522 1087 811⁄8 – – 11⁄4 – – 1120 – – 3952 1581 1129 811⁄8 791⁄2 361⁄2 11⁄4 18 1040 – 1758.0 1441.6 4262 1705 1218 893⁄8 – – 11⁄4 – – 1150 – – 4426 1770 1264 89 ⁄8 81 ⁄2 36 ⁄2 1 ⁄4 20 1090 – 3 1 1 1 Multiplier .955 Outdoor (input) .92 Outdoor (output) Multiplier x Nat. MBTUH = Pro. MBTUH † ELECTRICAL RATINGS Model Size †† With Pump 136-399 3.7 amps @ 120V (1/8 hp pump) 331-399 3.6 amps @ 120V (1/6 hp pump) 512-1826 7.2 amps @ 120V (1/2 hp pump) Subtract 55 lbs. when ordering GBC models. * Equipped with bronze headers, all other models have glasslined cast iron headers. GBC – cast iron headers. GBB – bronze headers. Add “N“ after model number for Low NOx configuration on 186-399 models. 23 24 Large Volume High-Power Electric 12 KW – 900 KW 208, 240, 277,380, 415, 480 and 600 Voltages Vertical Round,Vertical Square and Horizontal High Power Energy Saving Performance 150 to 2,500 Gallon Storage Rheem-Ruud large volume electric high power commercial water heaters are now available in 150 to 2,500 gallon storage – vertical round, vertical square and horizontal – with energy saving performance! Construction Features: • Glass lined steel tank • Incoloy heating elements • Internal fusing (above 120 amps) • Magnesium anodes • Immersion thermostat • Manual reset high limit • ASME temperature and pressure relief valve • Channel iron skid base (except 150 & 200 gallon round models) • 180° F temperature operation • 125 PSI working pressure • Handhole cleanout • 3 Year limited tank warranty Optional Features: • Low water cut-off • Pilot lights • Manual limiting switches • Alarm bell • Shunt trip disconnect (Field installed) • Low or high water pressure switch • Lifting lugs • Time clock (7 day or 24 hour) • Safety door interlock • Temperature and pressure gauges • Manway (250 gallon and larger only) • 150 psi or 160 psi working pressure • Electronic step controller • Seismic attachment point (250 gallon and larger – specify city, state and seismic zone) Certification and Ratings: • Efficiency – All models meet or exceed ASHRAE energy efficiency standards. • Safety and construction – ASME construction and National Board listed UL 1453 listed Dimensional Information MODEL NUMBER VERTICAL ROUND EVRO150 EVRO200 EVRO250 EVRO300 EVRO400 EVRO500 EVRO600 EVRO800 EVRO1000 VERTICAL SQUARE EVS1250 EVS1500 EVS2000 EVS2500 HORIZONTAL EHS0150 EHS0200 EHS0250 EHS0300 EHS0400 EHS0500 EHS0600 EHS0800 EHS1000 EHS1250 EHS1500 EHS2000 EHS2500 MAX. KW GALLON CAPACITY HEIGHT WIDTH DEPTH HEIGHT TO COLD INLET WATER CONNECTION INLET OUTLET APPROX. SHIP. WEIGHT 144 162 162 162 162 396 396 396 396 150 200 250 300 400 500 600 750 950 65-1/2 78 92 80 80 92 92 104 128 32 32 34 40 46 46 52 52 52 38-3/4 38-3/4 40-3/4 46-3/4 52-3/4 52-3/4 60-3/4 60-3/4 60-3/4 7-3/4 7-3/4 19-1/2 21 22-1/2 22-1/2 24-1/2 24-1/2 24-1/2 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 650 lbs. 750 lbs. 1,165 lbs. 1,350 lbs. 1,590 lbs. 1,700 lbs. 2,010 lbs. 2,450 lbs. 3,160 lbs. 900 900 900 900 1,250 1,500 2,000 2,500 132-1/2 128-1/2 140-1/2 146-1/2 64-1/2 70-1/2 76-1/2 82-1/2 64-1/2 70-1/2 76-1/2 82-1/2 23-1/4 25-1/4 27-1/4" 29 3 3 3 3 3 3 3 3 3,560 lbs. 4,120 lbs. 4,350 lbs. 5,750 lbs. 144 180 225 270 360 450 540 720 900 900 900 900 900 150 200 250 300 400 500 600 750 1,000 1,250 1,500 2,000 2,500 37 37 39 45 52 52 58 58 58 64 70 76 82 68-1/2 78 90-1/4 78-1/4 78-1/4 90-3/4 90-3/4 102-1/4 126-1/4 130-1/4 126-1/4 137-1/4 144-1/4 34-1/4 34-1/4 36-1/4 42-1/4 48-1/4 48-1/4 54-1/4 54-1/4 54-1/4 60-1/4 66-1/4 72-1/4 78-1/4 12 12 13 14-3/4 16 16 13-1/2 13-/12 13-1/2 15 16 17-1/2 16-1/2 2 2 2 2 2 2 2-1/2 2-1/2 2-1/2 3 3 3 3 2 2 2 2 2 2 2 2 2 3 3 3 3 1,180 lbs. 1,370 lbs. 1,450 lbs. 1,530 lbs. 1,750 lbs. 1,860 lbs. 2,340 lbs. 2,850 lbs. 3,040 lbs. 3,750 lbs. 4,340 lbs. 4,580 lbs. 6,060 lbs. • Vertical round models above 90 KW at 208V, 240V, or 380V and 162 KW at 415V, 480V or 600V exceed the capacity of a single control box and may require mulitple control panels. Consult the factory for specific details and optional construction. • Vertical square construction is available as an option for models that exceed the listed KW limits. • Control panel heights on vertical round models may exceed tank height – consult factory for specific heights on models with inputs above 72 KW. 25 26 Heavy-Duty Electric 6 KW – 81 KW Standard Features: • System Sentinel™ L.E.D. diagnostic system • Surface mounted and immersion thermostat models available • Lifeguard stainless steel elements • 208, 240, 277 and 480 voltages • 3 year limited tank warranty • Manual reset high limit control • Magnetic contactors and integral fusing • 1-1/2" NPT inlet/outlet dielectric nipples factory installed • 3" Rigid foam insulation (With Optional Seal Kit) • Heavy duty anode rods • Full port, full flow, brass drain valve • Factory installed AGA/ASME rated T&P relief valve • Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) In accordance with ANSI test procedures, these models tested below the maximum allowable standby loss levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). 11/2" HOT OUTLET NIPPLE B SYSTEM SENTINEL A AUTOMATIC TEMPERATURE CONTROL (IMMERSION ONLY) 361/8" 11/2" COLD INLET NIPPLE 5" RECOVERY CAPACITIES SURFACE MOUNTED THERMOSTATS Tank Capacity In Gallons 50 85 120 ES85-6-G ES85-9-G ES85-12-G ES85-15-G ES85-18-G ES85-24-G ES85-27-G ES85-30-G ES85-36-G ES85-45-G ES85-54-G N/A D Options: • UL Sanitation compliant models available • Thermostat staging • ASME construction available on E models MODEL NUMBERS ES50-6-G ES50-9-G ES50-12-G ES50-15-G ES50-18-G ES50-24-G ES50-27-G ES50-30-G ES50-36-G ES50-45-G ES50-54-G N/A C IMMERSION THERMOSTATS Tank Capacity In Gallons 50 85 120 ES120-6-G ES120-9-G ES120-12-G ES120-15-G ES120-18-G ES120-24-G ES120-27-G ES120-30-G ES120-36-G ES120-45-G ES120-54-G N/A E50-6-G E50-9-G E50-12-G E50-15-G E50-18-G E50-24-G E50-27-G E50-30-G E50-36-G E50-45-G E50-54-G N/A E85-6-G E85-9-G E85-12-G E85-15-G E85-18-G E85-24-G E85-27-G E85-30-G E85-36-G E85-45-G E85-54-G E85A-81-GS INPUT kW E120-6-G E120-9-G E120-12-G E120-15-G E120-18-G E120-24-G E120-27-G E120-30-G E120-36-G E120-45-G E120-54-G E120A-81-GS 6 9 12 15 18 24 27 30 36 45 54 81 DIMENSIONAL INFORMATION(All dimensions shown in inches) MODEL NUMBER E(S)50 E(S)85 E(2)120 A B C D 43-5/8 57-11/16 67-5/8 26-1/4 28-1/4 30-1/4 32 34 36 17-1/4 18-1/4 19-1/4 *ASME construction available only on Immersion Thermostat Models. APPROX. SHIPPING WEIGHT (LBS.) STD. ASME* 270 320 350 380 430 460 TEMPERATURE RISE – DEGREES F – GPH EQUIVALENT BTU/HR. 40° 62 92 123 154 184 246 276 307 369 461 553 838 20,473 30,709 40,946 51,182 61,418 81,891 92,128 102,364 122,837 153,546 184,256 276,388 60° 41 61 82 102 123 164 184 205 246 307 369 558 80° 31 46 61 77 92 123 138 154 184 230 276 419 100° 25 37 49 61 74 98 111 123 147 184 221 335 120° 21 31 41 51 61 82 92 102 123 154 184 279 140° 18 26 35 44 53 70 79 88 105 132 158 239 WATER TEMPERATURE RATINGS Model Number Thermostat Type ES50 Surface ES85, ES120 Surface E50, E85, E120 Immersion All models are North Carolina Code compliant. Minimum Delivered Temperature 90°F 120°F 90°F Maximum High Delivered Temperature Temperature Limit 160°F 160°F 190°F 180°F 190°F 200°F 27 28 PowerPack™ Small Volume ASME Electric 3 KW – 36 KW Standard Features: (With Optional Seal Kit) • System Sentinel™ L.E.D. diagnostic system • Immersion thermostat • Lifeguard stainless steel elements • 208, 240, 277 and 480 voltages • 3 year limited tank warranty • Manual reset high limit control • Magnetic contactors and integral fusing • 3/4" couplings • 2-1/2" Rigid foam insulation MODEL NUMBERS INPUT kW 3 6 9 12 15 18 24 27 30 36 IMMERSION THERMOSTATS Tank Capacity In Gallons 12 20 30 E12A-3-G E20A-3-G E30A-3-G E12A-6-G E20A-6-G E30A-6-G E12A-9-G E20A-9-G E30A-9-G N/A E20A-12-G E30A-12-G N/A E20A-15-G E30A-15-G N/A E20A-18-G E30A-18-G N/A N/A E30A-24-G N/A N/A E30A-27-G N/A N/A E30A-30-G N/A N/A E30A-36-G 40 E40A-3-G E40A-6-G E40A-9-G E40A-12-G E40A-15-G E40A-18-G E40A-24-G E40A-27-G E40A-30-G E40A-36-G • Heavy duty anode rods • Brass drain valve • Factory installed AGA/ASME rated T&P relief valve • Certified for a 160 PSI maximum working pressure • All models ASME certified B C 8" 3/4" D T&P SYSTEM SENTINEL A Options: • UL Sanitation compliant ring seal kits available 4 1/4" In accordance with ANSI test procedures, these models tested below the maximum allowable standby loss levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). AUTOMATIC TEMPERATURE CONTROL E 2 1/2" WATER TEMPERATURE RATINGS Model Number E12A E20A E30A E40A Tank Capacity Gallons 13 19.9 30 40 Thermostat Type Immersion Immersion Immersion Immersion Minimum Delivered Temperature 90°F 90°F 90°F 90°F Maximum Delivered Temperature 190°F 190°F 190°F 190°F High Temperature Limit 200°F 200°F 200°F 200°F RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises DIMENSIONAL INFORMATION All dimensions shown in inches MODEL NUMBER A B C D E APPROX. SHIPPING WEIGHT (LBS.) ASME E12A E20A E30A E40A 28-1/2 36-1/2 49-1/4 53-3/4 19 19 19 21 24-1/4 24-1/4 24-1/4 26-3/4 14-3/4 14-3/4 14-3/4 16-1/2 26-1/4 26-1/4 32-1/2 32-1/2 135 160 192 228 INPUT EQUIVALENT 40°F kW BTU/HR. (22.2°C) 3 10,236 31 6 20,473 62 9 30,709 93 12 40,946 124 15 51,183 155 18 61,420 186 24 81,893 248 27 92,129 279 30 102,366 310 36 122,839 372 60°F 80°F 100°F 120°F 140°F (33.3°C) (44.4°C) (55.6°C) (66.7°C) (77.8°C) 21 41 62 83 103 124 165 186 207 248 16 31 47 62 78 93 124 140 155 186 12 25 37 50 62 74 99 112 124 149 10 21 31 41 52 62 83 93 103 124 9 18 27 35 44 53 71 80 89 106 All models are North Carolina and Massachusetts Code compliant. 29 30 Eclipse™ 10-Year Electric 12 KW – 24 KW Standard Features: EXCLUSIVE 10 YEAR LIMITED TANk WARRANTY! • 85 and 105 gallon models • Inputs from 12, 18 and 24 KW • Staged element operation • 208, 240, 277 and 480 voltages, single or three phase • Plastic tank design – no anode rods • (4) Inconel heating elements • System Sentinel™ LED diagnostic system • Full port, full flow, brass drain valve • UL Sanitation listed • Less than half the weight of steel construction • Industry leading stand-by loss efficiencies D B C A MODEL NUMBERS INPUT kW 12 18 24 SURFACE MOUNTED THERMOSTATS Tank Capacity In Gallons 85 105 ME85-12-G ME105-12-G ME85-18-G ME105-18-G ME85-24-G ME105-24-G In accordance with ANSI test procedures, these models tested below the maximum allowable standby loss levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). WATER TEMPERATURE RATINGS Gallons Thermostat Type Minimum Delivered Temperature Maximum Delivered Temperature 85 Surface 90 160° 105 Surface 90 160° Tank Capacity RECOVERY CAPACITIES DIMENSIONAL INFORMATION Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises All dimensions shown in inches MODEL NUMBER A B C D APPROX. SHIPPING WEIGHT (LBS.) ASME 85 Gals 105 Gals. 28-1/4 30-1/4 66-1/4 66-1/2 70-1/4 70-3/4 4-1/2 4-1/2 170 185 INPUT kW 12 18 24 EQUIVALENT BTU/HR. 40,946 61,418 81,891 40°F 123 184 246 60°F 82 123 164 80°F 61 92 123 100°F 49 74 98 120°F 41 61 82 31 32 Booster Electric 6 KW – 54 KW Standard Features: • System Sentinel™ L.E.D. diagnostic system • Immersion thermostats • Manual reset high limit control • 208, 240, 277 and 480 voltages • 3 year limited tank warranty • Magnetic contactors and integral fusing Factory Accessories – • Solid state low water cut-off • Pressure reducing valve with bypass • Heavy duty anode rods • Durable brass drain valve • Factory installed AGA/ASME rated T&P relief valve • 6" stainless steel legs • UL Sanitation compliant • Certified for a 150 PSI max working pressure OPTIONAL THERMOSTATS (-GS MODELS ONLY) RECOVERY CAPACITIES MODEL INPUT EQUIVALENT NUMBER kW BTU/HR. E10-6-G 6 20,473 E10-9-G 9 30,709 E10-12-G 12 40,946 E10-15-G 15 51,182 E10-18-G 18 61,418 E10-24-G 24 81,891 E10-27-G 27 92,128 E10-30-G 30 102,364 E10-36-G 36 122,837 E10-45-G 45 153,546 E10-54-G 54 184,256 Approximate Weight – 110 Lbs. TEMPERATURE RISE – DEGREES F – GPH 40° 60° 80° 100° 120° 140° 62 41 31 25 21 18 92 61 46 37 31 26 123 82 61 49 41 35 154 102 77 61 51 44 184 123 92 74 61 53 246 164 123 98 82 70 276 184 138 111 92 79 307 205 154 123 102 88 369 246 184 147 123 105 461 307 230 184 154 132 553 369 276 221 184 158 THERMOSTAT 3/4" T&P 213/4" 11/4" HOT OUTLET NIPPLE 81/4" 11/4" COLD INLET NIPPLE OUTLET 43/4" 17" TEMPERATURE LIMIT CONTROL ELEMENT AND CLEANOUT ACCESS PANEL 133/4" 53/4" INLET TRANSFORMER TERMINAL BLOCK 6" 211/2" CONTACTORS FUSE BLOCKS (FUSED MODELS ONLY) WATER TEMPERATURE RATINGS Gallon Capacity Thermostat Type Minimum Delivered Temperature Maximum Delivered Temperature High Temperature Limit 10 Immersion 90°F 190°F 200°F These models meet the energy efficiency levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). All models are North Carolina Code compliant. 33 34 Light-Duty Electric 3 KW – 12 KW Standard Features: B DIA. • 208, 240, 277, and 480 voltages • Porcelain enamel lined tank • Heavy duty anode rod • 2-1/2" of rigid foam insulation • Baked enamel steel jacket • Patented resistor heating elements • Surface mounted thermostat • Manual reset high limit control • 3 year limited warranty • Certified for a 150 PSI maximum working pressure • Factory installed AGA/ASME rated T&P relief valve • Durable brass drain valve A 8" HOT WATER CONNECTION 3/4" T&P COLD WATER CONNECTION ANODE ROD WATER CONNECTIONS ALL 3/4" NPT ELECTRICAL CHARACTERISTICS AND CAPACITIES ELEMENT WATTAGE UPPER/LOWER RECOVERY CAPACITIES GPH @ TEMPERATURE RISE OF 40° 60° 80° 100° 120° FULL LOAD CURRENT (AMPS) (ALL TERMINALS) 208 240 277 480 3000/3000 31 20 15 12 10 14.4 12.5 10.8 6.3 4000/4000 41 27 20 16 13 19.2 16.7 14.4 8.3 4500/4500 46 31 23 18 15 21.6 18.8 16.2 9.4 5000/5000 51 34 26 20 17 24 20.8 18.1 10.4 6000/6000 61 41 31 25 20 28.8 25 21.7 12.5 ELECTRICAL CHARACTERISTICS AND CAPACITIES (Simultaneous /Three Phase Operation) ELEMENT WATTAGE UPPER/LOWER RECOVERY CAPACITIES GPH FULL LOAD CURRENT (AMPS) @ TEMPERATURE RISE OF (TERMINAL L3/TERMINALS L1 & L2) 40° 60° 80° 100° 120° 208 240 480 3000/3000 61 41 31 24 20 4000/4000 81 54 41 32 27 33.3/19.2 28.9/16.7 14.4/8.3 4500/4500 91 61 45 37 31 37.5/21.6 32.5/18.8 16.2/9.4 5000/5000 102 68 51 41 34 41.6/24 36.1/20.8 18/10.4 6000/6000 122 81 61 49 41 N/A 43.3/25.0 21.7/12.5 25/14.4 DIMENSIONAL INFORMATION (All dimensions shown in inches) (Non-Simultaneous /Single or Three Phase Operation) 21.7/12.5 10.8/6.3 A B MODEL TANk CAPACITY NUMBER GALLONS ELDS30 30 29-1/2 22-1/4 ELDS40 38 31-1/2 23 ELDS52 47 32-1/2 26-1/4 ELD30 30 45-1/2 17-3/4 ELD40 40 46-1/4 22-1/4 ELD52 50 57 22-1/4 ELD66 65 58-3/4 23 ELD80 80 59 24-1/2 ELD120 120 62-1/2 28-1/4 WATER TEMPERATURE RATINGS: Thermostat Type: Surface Mounted Min. Delivered Temperature: 110° F Max. Delivered Temperature: 170° F High Temperature Limit: 190° F APPROX. SHIPPING WEIGHT (LBS.) 105 135 150 90 108 127 170 200 330 These models have been tested according to DOE test procedures, and exceed the minimum energy factor requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). All models are North Carolina and Massachusetts Code compliant. 35 36 Point-of-Use Electric 1,440 – 6,000 WATTS Standard Features: • 120, 208, 240, 277 and 480 voltages • Porcelain enamel lined tank • Heavy duty anode • Rigid foam insulation • Baked enamel steel jacket • Resistor heating element • Surface mounted thermostat • Manual reset high limit control • 3 year limited warranty • Certified for a 150 PSI maximum working pressure • Factory installed AGA/ASME rated T&P valve • Optional wall mounting kit DIMENSIONAL INFORMATION (All dimensions shown in inches)* MODEL EGSP2 EGSP6 EGSP10 EGSP15 EGSP20 EGSP30 MIN WATTS 1,440 1,500 1,500 1,500 1,500 1,500 A B C D E MAX TANk WATTS GALLONS 1,500 2-1/2 14 9-3/4 — — 6,000 6 15-1/8 15-3/4 12-5/8 11-5/8 6,000 10 22-7/8 15-3/4 20-3/8 19-3/8 6,000 15 24-1/4 17-3/4 21-7/8 19-3/8 6,000 19.9 25-1/8 19-3/4 22-5/8 19-5/8 6,000 30 30 21-3/4 23 23 — 4-1/4 4-1/4 4-5/8 5-1/8 2-3/4 SHIPPING WEIGHT (LBS.) 18 41 53 65 76 115 Water Temperature Ratings: Thermostat Type: Surface MODELS: EGSP6 EGSP10 EGSP15 EGSP20 EGSP30 Min. Delivered Temperature: 110°F Max. Delivered Temperature: 170°F High Temperature Limit: 190°F B B DIA. 3/4" T&P HOT WATER CONNECTION A C A COLD WATER INLET 3/4" T&P D E Water Connections 3/4" NPT MODEL: EGSP2 Water Connections 1/2" NPT ELEMENT AVAILABILITY WATTAGE 1,440 1,500 2,000 2,500 3,000 4,500 6,000 31/2" COLD WATER CONNECTION 120 V 208 V **Y N/A Y Y Y Y Y Y Y Y N/A Y N/A Y 240 V 277 V 480 V N/A N/A N/A **Y N/A N/A Y Y Y Y N/A N/A Y Y Y *Y *Y *Y Y Y Y *Not available in EGSP6 & EGSP10 **EGSP2 available only in these configurations. ELECTRICAL CHARACTERISTICS ELEMENT WATTAGE Mounted Basic model numbers are listed. When ordering specify electrical input to determine specific model number: Basic Model: EGSP6 Specified Input: 6,000 Watts Specified Model Number: EGSP6-6 Use CEGSP Prefix for Canadian Models. HOT WATER OUTLET These models meet the minimum energy factor requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). All models are North Carolina and Massachusetts Code compliant. FULL LOAD CURRENT IN AMPERES 120 V 208 V 240 V 277 V 480 V 1,440 12.0 N/A N/A N/A N/A 1,500 12.5 7.2 6.3 N/A N/A 2,000 16.7 9.6 8.3 7.2 4.2 2,500 20.8 12.0 10.4 N/A N/A 3,000 25.0 14.4 12.5 10.8 6.3 4,500 N/A 21.6 18.8 16.2 9.4 6,000 N/A 28.8 25.0 21.7 12.5 All models employ 1 heating element resulting in a 2-wire outlet (single phase) electrical configuration. RECOVERY CAPACITIES ELEMENT WATTAGE 1,440 1,500 2,000 2,500 3,000 4,500 6,000 TEMPERATURE RISE - DEGREES F GALLONS PER HOUR 40°F 60°F 80°F 100°F 120°F 140°F 15 15 20 25 30 46 61 10 10 14 17 20 30 41 7 8 10 13 15 23 30 6 6 8 10 12 18 24 5 5 7 8 10 15 20 4 4 6 – 9 13 17 37 38 Indirect Water Heaters Construction Features: Anode Rod Hot Outlet, 1-1/2" NPT • 30, 38, 45, 75 and 110 gallon models • Heavy gauge steel tank • High temperature porcelain enamel protect all tank and coil • Factory installed automatic temperature controls • Factory installed brass drain valve • Temperature and pressure relief valve • 1-1/2" coil diameter • 2" Non-CFC foam insulation • Two heavy-duty magnesium anode rods • Factory installed dielectric nipples Hot Outlet/ Anode Rod, 3/4" NPT Anode Rod Anode Rod T&P Relief Valve T&P Relief Valve From Boiler, 1" NPT From Boiler, 1" NPT Aquastat B C B D C Aquastat To Boiler, 1" NPT Drain Valve E G D F To Boiler, 1"NPT Drain Valve E G A UNITS inches inches inches inches inches Cold Inlet, 1" NPT STID80 & STID120 A B C D E F G H APPROX. SHIPPING WEIGHT 22 22 22 24 28 35-3/4 42-3/4 48-3/4 64-1/8 65-1/4 27-3/4 34-3/4 39-3/4 57-1/8 57-3/4 18-1/2 31-1/2 31-1/2 33 33-3/4 11-3/4 16-3/4 16-3/4 19-1/4 16-1/4 6-1/2 6-1/2 6-1/2 8 8-3/4 4-1/2 4-1/2 4-1/2 5 5 N/A N/A N/A 5 6-1/2 180 lbs 226 lbs 231 lbs. 297 lbs. 397 lbs. FIRST HOUR RATING (gal) @ Coil Output (Btu/hr) MODEL NUMBER STID30 STID40 STID50 STID80 STID120 TANK FIRST HEAT SOURCE CAPACITY DRAW FRICTION LOSS* (FT. W.C.) (GAL) (GAL) 30 25 2 38 33 3 45 40 3 75 70 5 110 102 5 180°F, 8 GPM** 180°F, 10 GPM** 115 @ 56,000 117 @ 57,000 173 @ 89,000 183 @ 96,000 180 @ 89,000 190 @ 96,000 233 @ 104,000 245 @ 111,000 265 @ 104,000 277 @ 111,000 A STID30, STID40 & STID50 F H DIMENSIONAL INFORMATION MODEL NUMBER STID30 STID40 STID50 STID80 STID120 Cold Inlet, 3/4" NPT 180°F, 12 GPM** 200°F, 8 GPM** 200°F, 10 GPM** 200°F, 12 GPM** 200°F, 14 GPM** 118 @ 58,000 191 @ 101,000 198 @ 101,000 254 @ 117,000 286 @ 117,000 138 @ 71,000 214 @ 115,000 221 @ 115,000 277 @ 132,000 309 @ 132,000 144 @ 75,000 226 @ 123,000 233 @ 123,000 292 @ 141,000 324 @ 141,000 149 @ 78,000 235 @ 129,000 242 @ 129,000 304 @ 149,000 336 @ 149,000 154 @ 81,000 243 @ 134,000 250 @ 134,000 314 @ 155,000 346 @ 155,000 All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATERS TESTING STANDARD IWH-TS-1_MARCH 2003 *At 8 GPM **Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water. Note: First Hour Rating = First Dray + Continuous Draw Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z.21.10.1. Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F. Rheem recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding. Pressures (all): Test pressure, 300 psi; working pressure, 150 psi Standard Voltage (all): 120V, 60 Hz, 1P T&P valve installed 39 40 Storage Tanks 80 – 175 GAL. Standard Features: • Porcelain enamel lined tank • Heavy duty anode rods • ASME construction available • 2" of rigid foam insulation • Baked enamel steel jacket • 5 year limited warranty These models exceed the minimum efficiency requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact). DIMENSIONAL INFORMATION (DIMENSIONS SHOWN IN INCHES) WATER CONNECTIONS TOP FRONT OUTLET SIDES APPROX. WEIGHT (LBS.) STANDARD ASME 1" NPT T&P OPENING MODEL NUMBER A B C D ST80(A) 58-5/16 24-3/16 13-3/16 6-3/16 2 2 220 lbs. 260 lbs. ST100(A) 46 32-1/4 12-9/16 5-9/16 – 2 475 lbs. 475 lbs. ST120(A) 59-1/4 28-1/4 11-1/16 4-1/16 2 2 300 lbs. 340 lbs. ST175(A) 67-1/4 32-1/4 12-9/16 5-9/16 2-1/2 2-1/2 600 lbs. 600 lbs. HOT OUTLET OPENING HOT 3/4" NPT THERMOMETER OPENING B T&P OPENING B 3/4" NPT THERMOMETER OPENING TANk INFORMATION MODEL NUMBER ST80(A) ST100(A) ST120(A) ST175(A) TANk CAPACITY (GALLONS) 80 100 115 175 MAXIMUM WORkING PRESSURE STD. ASME 150 PSI 125 PSI 150 PSI 160 PSI 150 PSI 160 PSI 150 PSI 150 PSI 3/4" NPT AQUASTAT OPENING 3/4" NPT AQUASTAT OPENING A 39-15/16 A 2” OPENINGS FOR CIRCULATING LINES CIRCULATING CONNECTIONS C D D C 3/4" NPT DRAIN OPENING ST100(A) ST80(A), ST120(A), ST175(A) 41 42 Large Volume Storage Tanks 200 – 940 GAL. 1-1/4" NPT T&P (ST260A AND ABOVE) Standard Features: • Available in jacketed and non-jacketed models • 200, 260, 320, 430, 500, 750 and 950 gallon capacities • Porcelain enamel lined tank • Heavy duty anode rods • 2" of rigid foam insulation • Baked enamel steel jacket • 5 year limited warranty • All large volume commercial storage tanks are certified to ASME heater and pressure vessel code standards 2" NPT TANk INFORMATION (Shown in English & Metric) 1" NPT RELIEF VALVE OPENING (ST200A) B MODEL NUMBER A 3/4" NPT AQUASTAT OPENING D 1" DRAIN PIPE MAXIMUM WORkING PRESSURE ASME TANk CAPACITY GALLONS LITERS ST(U)200A 200 758 150 PSI ST(U)260A 257 974 125 PSI ST(U)320A 318 1205 125 PSI ST(U)430A 432 1637 125 PSI ST(U)500A 504 1910 125 PSI ST(U)750A 752 2850 125 PSI ST(U)950A 940 3563 125 PSI 1034 kPa C 862 kPa 2" 862 kPa 862 kPa B 862 kPa A 3/4" 862 kPa C D 862 kPa 4" DIMENSIONAL INFORMATION FOR VERTICAL ROUND JACkETED STORAGE TANkS DIMENSIONAL INFORMATION FOR VERTICAL BARE (NON-JACkETED) STORAGE TANkS (All dimensions shown in English and Metric) MODEL NUMBER UNITS A ST200A inches mm ST260A inches ST320A ST430A ST500A mm ST750A inches 107-1/2 ST950A inches 131-1/2 (All dimensions shown in English and Metric) WATER CONNECTIONS TOP FRONT OUTLET SIDE APPROX. SHIPPING WEIGHT MODEL NUMBER UNITS A STU200A inches mm STU260A STU320A STU430A STU500A STU750A STU950A mm B C D 77-1/4 32 11-1/2 17-1/4 2 2-1/2 500 lbs. 1962 813 292 438 51 63.5 227 kgs. 95-1/2 34 18 26 2 3 1108 lbs. mm 2426 864 457 660 51 76 503 kgs. inches 84-1/2 40 19-3/4 27-1/4 2 3 1290 lbs. mm 2146 1016 502 692 51 76 586 kgs. inches 84-1/2 46 21 29 2 3 1626 lbs. mm 2146 1168 533 737 51 76 738 kgs. inches 94-1/2 46 21 29 2 3 1765 lbs. 2400 1168 533 737 51 76 801 kgs. 54 22-7/8 30-7/8 2 3 2330 lbs. mm mm 2731 3340 1372 581 784 51 76 1058 kgs. 54 22-7/8 30-7/8 2 3 3010 lbs. 1372 581 784 51 76 1367 kgs. D WATER CONNECTIONS TOP FRONT OUTLET SIDE APPROX. SHIPPING WEIGHT B C 75-3/4 28 14-5/8 18 2 3 1924 711 371 157 51 76 222 kgs. inches 88 30 15-3/4 23-3/4 2 3 464 lbs. mm 2235 762 400 603 51 76 211 kgs. inches 76 36 17-3/8 25-3/8 2 3 574 lbs. mm 1930 914 441 645 51 76 261 kgs. inches 76 42 18-7/8 26-7/8 2 3 816 lbs. mm 1930 1067 479 683 51 76 370 kgs. inches 88 42 18-7/8 26-7/8 2 3 925 lbs. mm 2235 1067 479 683 51 76 420 kgs. inches 100 48 20-7/8 28-7/8 2 3 1387 lbs. mm 2540 1219 530 733 51 76 630 kgs. inches 124 48 20-7/8 28-7/8 2 3 1651 lbs. 3150 1219 530 733 51 76 750 kgs. 488 lbs. Jacketed models meet or exceed the minimum efficiency requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact). 43 44 Trouble Zone EasytoInstall Zone 156,000 BTU 199,900 BTU 250,000 BTU 300,000 BTU 360,000 BTU 399,900 BTU Competitors’ larger units mean a difficult installation. Universal’s heavy duty gas models are shorter and narrower for easy and convenient installation. CertiSpec 3.2 What’s new? 32-bit upgrade! What does that mean? Well, nothing you can see or touch, but this major enhancement is the engine that drives many of the new features. New Features: • Internet Upgrades! No more “new” versions • Internet or mail-in registration (no mandatory registration either!) • Fuel Cost Calculator • User defined (imported) business logo/info on job spec document • Long File Name recognition • Most recent projects listed under File Menu • Multiple open projects • Direct CS3 to CS3 email attachment of project file NOW INCLuDES SPIDERFIRE MODELS! Additional Models: • SPIDERfire sizing • Small Volume ASME cross reference • Low NOx sizing • Large Volume Storage Tank reference Computer Requirements: • Windows 95/98 or NT 4.X • Pentium 90 or higher required • 16 megabyte RAM (32 recommended) • Disk Space: 4-6 megabytes (estimated) • Internet connection required for email and Upgrade Download • 800 x 600 screen resolution 45 46 A.O. SMITH TO RHEEM-RUUD CONVERSION CHART A.O. SMITH Model Btu/Hr. RHEEM-RUUD Gal Dia. Height Model 71 81 81 100 100 81 100 100 65 100 65 85 100 85 27-3/4" 27-3/4" 27-3/4" 27-3/4" 27-3/4" 27-3/4" 30-1/4" 30-1/4" 27-3/4" 30-1/4" 27-3/4" 27-3/4" 30-1/4" 27-3/4" 69-3/4" 73" 67-1/2" 74" 74" 67-1/2" 72" 72" 75" 72" 75" 79-1/2" 75-1/2" 82-1/4" G75-125 G82-156 G76-180 G100-200 G100-200 G76-200 G100-200(A) G100-250(A) G72-250(A) G100-270(A) G72-300(A) G65-360(A) G100-400(A) GX90-550(A) Btu/Hr. Gal Dia. Height 75 82 76 100 100 76 100 100 72 100 72 65 100 90 26-1/4" 26-1/4" 26-1/4" 30-1/4" 30-1/4" 26-1/4" 30-1/4" 30-1/4" 26-1/4" 30-1/4" 26-1/4" 26-1/4" 30-1/4" 30" 65-1/2" 68-13/16" 68-13/16" 73-1/16" 73-1/16" 68-13/16" 73-1/16" 73-1/4" 71-1/16" 73-7/8" 71" 70-11/16" 76" 74-1/2" 75,000 75,000 75 100 26-1/4" 28-1/4" 64-3/8" 69-5/8" Gas Tank Type Models BTR-120 BTR-154 BTR-180 BTR-197 BTR-198 BTR-199 BTR-200(A) BTR-250(A) BTR-251(A) BTR-275(A) BTR-305(A) BTR-365(A) BTR-400(A) BTR-500(A) 120,000 154,000 180,000 199,000 199,000 190,000 199,000 250,000 251,000 275,000 305,000 365,000 399,000 500,000 125,000 156,000 180,000 199,900 199,900 199,900 199,900 250,000 250,000 270,000 300,000 360,000 399,900 550,000 Conservationist/Damper – Gas Tank Type Models BT-80 75,000 75 25-1/2" BT-100 75,000 100 26-1/2" NOTE: (A) denotes ASME construction available. 61-1/8" 68-3/4" G75-75 G100-80 HE80-130 HE119-160 HE119-199 130,000 160,000 199,000 80 119 119 23-1/2" 27" 27" 72" 73" 73" GD-100-250(A) GD-100-270(A) GD-100-310(A) GD-100-360(A) 250,000 270,000 310,000 360,000 100 100 100 100 30-1/4" 30-1/4" 30-1/4" 30-1/4" 73-1/2" 73-1/2" 73-1/2" 73-1/2" GHE100-160 GHE-100-200(A) GHE-100-250(A) GHE-100-300(A) 160,000 199,900 250,000 300,000 100 100 100 100 26-1/4" 26-1/4" 26-1/4" 26-1/4" 78-3/4" 78-3/4" 78-3/4" 78-3/4" Sealed Combustion Gas-Fired BTH-120 125,000 BTH-150 150,000 BTH-199 199,000 60 100 100 27-3/4" 27-3/4" 27-3/4" 55-1/2" 74-1/2" 74-1/2" Induced Draft Models BTI250(A) 250,000 BTI275(A) 275,000 BTI310(A) 310,000 BTI366(A) 366,000 100 100 85 85 27-3/4" 27-3/4" 27-3/4" 27-3/4" 72" 72" 73" 73" High Efficiency Models BTH-150 150,000 BTH-199 199,000 BTH-150(A) 240,000 BTH-300(A) 300,000 100 100 100 130 27-3/4" 27-3/4" 27-3/4" 33" 74-1/2" 74-1/2" 74-1/2" 74" 47 48 A.O. SMITH TO RHEEM-RUUD CONVERSION CHART A.O. SMITH Model Btu/Hr. RHEEM-RUUD Gal Model Btu/Hr. Gal Gas – Hot Water Supply Heaters HW-120 HW-160 HW-200 HW-225 HW-300 HW-399 HW-420 HW-520 HW-670 HW-1240 HW-1340 DW-720 DW-840 120,000 160,000 199,000 225,000 300,000 399,000 420,000 520,000 670,000 1,240,000 1,340,000 720,000 840,000 DW-960 960,000 DW-1080 1,080,000 DW-1210 1,210,000 DW-1350 1,350,000 DW-1480 1,480,000 DW-1610 1,610,000 DW-1810 1,810,000 NOTE: ** Denotes less than 1 gallon storage capacity. ** ** ** ** ** ** ** ** ** ** ** ** ** GBB/GBBP-136 GBC/GBCP-186 GBC/GBCP-186 GBC/GBCP-264 GBC/GBCP-331 GBC/GBCP-399 GBC/GBCP-399 GX90-550 GX90-640 GBC/GBCP-1223 GBC/GBCP-1337 GBC/GBCP-726 GBC/GBCP-825 136,000 181,000 181,000 264,000 334,000 399,000 399,000 550,000 640,000 1,222,500 1,336,600 726,000 825,000 ** ** ** ** ** ** ** 90 90 ** ** ** ** ** ** ** ** ** ** ** GBC/GBCP-962 GBC/GBCP-1125 GBC/GBCP-1223 GBC/GBCP-1337 GBC/GBCP-1467 GBC/GBCP-1630 GBC/GBCP-1826 961,700 1,124,700 1,222,500 1,336,600 1,467,000 1,630,000 1,825,600 ** ** ** ** ** ** ** ** ** ** ** 80 115 115 200 Storage Tank Systems (**Unfired Storage Vessels) TJ-80(A) ** 80 TJV-120M ** 120 TJV-120A ** 120 TJV-200 ** 200 NOTE: See large volume storage tanks, page 40 and 41. ST80(A) ST120 ST120A ST200A 49 50 A.O. SMITH TO RHEEM-RUUD CONVERSION CHART A.O. SMITH Model kW RHEEM-RUUD Gal Model kW Gal EGSP6 EGSP10 EGSP15 EGSP20 ELD/ELDS30 ELD/ELDS40 ELD/ELDS52 ELD66 ELD80 ELD120 6 Max 6 Max 6 Max 6 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 6 10 15 20 30 40 50 65 80 120 Electric – Light Duty and Point-of-Use Products DEL-6 S DEL-10 S DEL-15 S DEL-20 S DEN/DEL-30 D DEN/DEL-40 D DEN/DEL-52 D DEN-66 D DEN-80 D DEN-120 D 2.5 Max 6 Max 6 Max 6 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 6 10 15 20 30 40 50 66 80 119 Electric – Heavy Duty Products DRE/DVE-52 6 to 54 50 ES50/E50 6 to 54 DRE/DVE-80 6 to 54 80 ES85/E85 6 to 54 DRE/DVE-120 6 to 54 119 ES120/E120 6 to 54 DSE-10 3 to 6 10 E12A 3 to 9 DSE-20 3 to 18 20 E20A 3 to 18 DSE-30 3 to 24 30 E30A 3 to 36 DSE-40 3 to 36 40 E40A 3 to 36 DSE-50 6 to 45 50 E50A 6 to 54 DSE-65 6 to 54 65 E85A 6 to 54 DSE-80 6 to 54 80 E85A 6 to 54 DSE-100 6 to 54 100 E120A 6 to 54 DSE-120 6 to 54 120 E120A 6 to 54 NOTE: “DRE”, “DEL”, “DEN” use surface mounted thermostats. “DVE”, “DSE” use immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats. 50 85 120 13 20 30 40 50 85 85 120 120 Electric – Instantaneous/Booster Products CMC-5 SU-20 6 to 54 6 to 54 5 20 E10 E10 6 to 54 6 to 54 10 10 51 52 AMERICAN TO RHEEM-RUUD CONVERSION CHART AMERICAN Model DCG32 Series 75T125-5N 36S145-6N 75T160-6N 80T180-6N 80T199-6N 98T199-6N 80T250-6N(A) 98T250-6N(A) 75T300-7N(A) 65T370-8N(A) 65T399-8N(A) 80T425-10N(A) PVDCG32 Series 65T625-8N(A) 80T725-8N(A) DCG31 Series 73T140-5N 76T180-6N 85S199-6N 100T199-6N 100S199-6N 100S250-6N(A) 100S270-6N(A) 100S300-7N(A) 80L399-8N(A) 80L505-10N(A) PVCG32 Series 50T63-3NV 75T80-3NV CG32 Series 75T75-4NV 100T88-4NV RHEEM-RUUD Btu/Hr. Gal Dia. Height Model 125,000 145,000 160,000 180,000 199,999 199,999 250,000 250,000 300,000 370,000 399,999 425,000 75 36 75 80 80 98 80 98 75 65 65 80 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 72" 50-5/8" 72" 71-7/8" 71-7/8" 82-7/8" 71-7/8" 82-7/8" 74-1/2" 73-3/8" 73-3/8" 83" G75-125 G37-200 G82-156 G76-180 G76-200 G91-200 G72-250(A) G100-250(A) G72-300(A) G65-360(A) G65-400(A) GX90-550(A) 625,000 725,000 65 80 28-1/4" 28-1/4" 69-3/8" 79-5/8" 140,000 180,000 199,999 199,999 199,999 250,000 270,000 300,000 399,999 505,000 73 76 85 100 100 100 100 100 75 80 28-1/4" 28-1/4" 30-1/4" 28-1/4" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 63,500 80,000 50 75 74,500 88,000 75 100 Btu/Hr. Gal Dia. Height 125,000 199,900 156,000 180,000 199,900 199,900 250,000 250,000 300,000 360,000 399,900 550,000 75 35 82 76 76 91 72 100 72 65 65 90 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 30-1/4" 26-1/4" 26-1/4" 26-1/4" 30" 65-1/2" 49-1/4" 68-13/16" 68-13/16" 68-13/16" 76-5/16" 71-1/16" 73-1/4" 71" 70-11/16" 70-11/16" 74-1/2" GX90-640(A) GX90-715(A) 640,000 715,000 90 90 30" 30" 74-1/2" 74-1/2" 74-1/4" 74-1/4" 69" 78" 74-1/2" 74-1/2" 74-1/2" 74-1/2" 71" 69" G82-156 G76-180 G76-200 G91-200 G100-200 G100-250(A) G100-270(A) G100-310(A) G65-400(A) GX90-550(A) 156,000 180,000 199,900 199,900 199,900 250,000 270,000 310,000 399,900 550,000 82 76 76 91 100 100 100 100 65 90 26-1/4' 26-1/4" 26-1/4" 26-1/4" 30-1//4" 30-1/4" 30-1/4" 30-1/4" 26-1/4" 30" 68-13/16" 68-13/16" 68-13/16" 76-5/16" 73-1/16" 73-1/4" 73-7/8" 75" 70-11/16" 74-1/2" 22" 26" 70" 70-1/2" GPV75-75E GPV75-75E 75,000 75,000 75 75 26-1/4" 26-1/4" 68" 68" 26" 28-1/4" 63-1/2" 68-11/16" G75-75 G100-75 75,000 75,000 75 100 26-1/4" 26-1/4" 64-3/8" 67-7/8" 53 54 AMERICAN TO RHEEM-RUUD CONVERSION CHART AMERICAN Model kW RHEEM-RUUD Gal Model kW Gal 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 30 40 50 65 80 120 6 to 54 6 to 54 6 to 54 6 to 54 50 85 120 120 ** ** ** ** 80 115 115 200 Electric – Light Duty and Point-of-Use Products LDCE30D LDCE40D LDCE50D LDCE65D LDCE80D LDCE119D 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 30 40 50 65 80 119 ELDS30 ELD40 ELD52 ELD66 ELD80 ELD120 Electric – Heavy Duty Products ITCE/STCE-33 9 to 54 50 ES50/E50 ITCE/STCE-33 9 to 54 80 ES85/E85 ITCE/STCE-33 9 to 54 119 ES120/E120 AITCE/ASTCE-33 9 to 54 119 E120A NOTE: “STCE” uses surface mounted thermostats. “ITCE” uses immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats. Storage Tank Systems (**Unfired Storage Vessels) CST52-80T ** 80 CST52-120T ** 119 ACST52-120T ** 120 ACST52-200T ** 200 NOTE: See large volume storage tanks, page 40 and 41. ST80 ST120 ST120A ST200A 55 56 BRADFORD WHITE TO RHEEM-RUUD CONVERSION CHART BRADFORD WHITE Model RHEEM-RUUD Btu/Hr. Gal Dia. Height 75T-80 100T-88 D-75T-125-3N D-38T-155 D-75T-160-3N D-80T-180-3N D-80T-199-3N D-100T-199-3N D-100S-199-3N D-80T-250-3N(A) D-100S-250-3N(A) D-100T-250-3N(A) D-100S-270-3N(A) D-75T-300-3N(A) D-65T-370-3N(A) D-65T-399-3N(A) D-80S-399-3N(A) D-80T-425-3N(A) D-80T-505-3N(A) 80,000 88,000 125,000 155,000 160,000 180,000 199,999 199,999 199,999 250,000 250,000 250,000 270,000 300,000 370,000 399,999 399,999 425,000 505,000 75 100 75 38 75 80 80 98 100 80 100 98 100 75 65 65 80 80 80 26" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 30-1/4" 28-1/4" 30-1/4" 28-1/4" 30-1/4" 28-1/4" 28-1/4" 28-1/4" 30-1/4" 28-1/4" 28-1/4" 63-3/4" 68-5/8" 72-1/8" 51" 72-1/8" 71-7/8" 71-7/8" 83" 74-1/4" 71-7/8" 74-1/4" 83" 74-1/4" 74" 74" 74" 77-1/4" 83" 83" D-80S-512-3N(A) D-65T-625-3N(A) D-80T-725-3N(A) 512,000 625,000 725,000 80 65 80 30-1/4 28" 28" 199,999 250,000 270,000 300,000 399,999 450,000 505,000 100 100 100 100 80 80 80 65,000 75,000 199,900 Model Btu/Hr. Gal Dia. Height G75-75 G100-75 G75-125 G37-200 G82-156 G76-180 G76-200 G91-200 G100-200 G72-250(A) G100-250(A) G100-250(A) G100-270(A) G72-300(A) G65-360(A) G65-400(A) G85-400(A) GX90-550(A) GX90-550(A) 75,000 75,000 125,000 199,900 156,000 180,000 199,900 199,900 199,990 250,000 250,000 250,000 270,000 300,000 360,000 399,900 399,900 550,000 550,000 75 100 75 35 82 76 76 91 100 72 100 100 100 72 65 65 85 90 90 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 30-1/4" 26-1/4" 30-1/4" 30-1/4" 30-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 30" 30" 64-3/8" 67-7/8" 65-1/2" 49-1/4" 68-13/16" 68-13/16" 68-13/16" 76-5/16" 73-1/16" 71-1/16" 73-1/4" 73-1/4" 73-7/8" 71" 70-11/16" 70-11/16" 78-13/16" 74-1/2" 74-1/2" 75-3/4" 68-7/8" 79-1/8" GX90-550(A) GX90-640(A) GX90-715(A) 550,000 640,000 715,000 90 90 90 30" 30" 30" 74-1/2" 74-1/2" 74-1/2" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 30-1/4" 74-3/4" 74-3/4" 74-3/4" 75-1/2" 71" 69" 69" G100-200 G100-250(A) G100-270(A) G100-310(A) G65-400(A) GX90-550(A) GX90-550(A) 199,990 250,000 270,000 310,000 399,900 550,000 550,000 100 100 100 100 65 90 90 30-1/4" 30-1/4" 30-1/4" 30-1/4" 26-1/4" 30" 30" 73-1/16" 73-1/4" 73-7/8" 75" 70-11/16" 74-1/2" 74-1/2" 48 75 100 22" 26" 28-1/4" 66-1/4" 69-1/2" 77" GPV75-75E GPV75-75E GP100-200 75,000 75,000 199,900 75 75 100 26-1/4" 26-1/4" 30-1/4" 68" 68" 81-3/4" 60 60 60 100 100 100 100 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 57" 57" 57" 78" 78" 78" 78" HE80-130 HE80-160 HE80-199 GHE100-130 GHE100-160 GHE100200(A) GHE100-250(A) 130,000 160,000 199,000 130,000 160,000 199,900 250,000 80 80 80 100 100 100 100 23-1/2" 23-1/2" 23-1/2" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 72" 72" 72" 78-3/4" 78-3/4" 78-3/4" 78-3/4" T&S Series L Series D-100L-199 D-100L-250(A) D-100L-270(A) D-100L-300(A) D-80L-399(A) D-80L-450(A) D-80L-505(A) TW & PDV Series TW50T-65-3N TW75T-75-3N PDV100S-200-3N High Efficiency Models EF60T-125E-3N(A) EF60T-150E-3N(A) EF60T-199E-3N(A) EF100T-150-3N(A) EF100T-199-3N(A) EF100T-250-3N(A) EF100T-300-3N(A) 125,000 150,000 199,999 150,000 199,999 250,000 300,000 57 58 BRADFORD WHITE TO RHEEM-RUUD CONVERSION CHART BRADFORD WHITE Model Btu/Hr. RHEEM-RUUD Gal Model Btu/Hr. Gal 136,000 136,000 181,000 181,000 264,000 334,000 399,000 511,500 627,000 726,000 961,700 ** ** ** ** ** ** ** ** ** ** ** 1,222,500 1,467,000 1,825,600 2,249,400 2,673,200 2,934,000 ** ** ** ** ** ** Gas – Hot Water Supply Heaters L-I-T1 Series 90-5N-PF1 135-5N-PF1 180-5N-PF1 225-5N-PF1 270-5N-PF1 315-5N-PF9 360-5N-PF9 495-5N-PF9 645-5N-PF9 745-5N-PF9 985-5N-PF9 90,000 135,000 180,000 225,000 270,000 315,000 360,000 495,000 645,000 745,000 985,000 1255-5N-PF9 1,255,000 1435-5N-PF9 1,435,000 1795-5N-PM9 1,795,000 2065-5N-PM9 2,065,000 2620-5N-PM9 2,620,000 3080-5N-PM9 3,080,000 NOTE: ** Denotes less than 1 gallon storage capacity. ** ** ** ** ** ** ** ** ** ** ** GBB/GBBP-136 GBB/GBBP-136 GBC/GBCP-186 GBC/GBCP-186 GBC/GBCP-264 GBC/GBCP-331 GBC/GBCP-399 GBC/GBCP-512 GBC/GBCP-627 GBC/GBCP-726 GBC/GBCP-962 ** ** ** ** ** ** GBC/GBCP-1223 GBC/GBCP-1467 GBC/GBCP-1826 (2)-GBC/GBCP-1125 (2)-GBC/GBCP-1337 (2)-GBC/GBCP-1467 Storage Tank Systems (**Unfired Storage Vessels) M-3-ST80R5 ** 80 M-3-ST120R5 ** 119 M-3-ST120R5(A) ** 119 M-3-ST200R5(A) ** 200 NOTE: See large volume storage tanks, page 40 and 41. ST80(A) ST120(A) ST120A ST200A ** ** ** ** 80 115 115 200 59 60 BRADFORD WHITE TO RHEEM-RUUD CONVERSION CHART BRADFORD WHITE Model kW RHEEM-RUUD Gal Model kW Gal 12 20 30 40 50 80 119 E12A E20A E30A E40A ES/E50(A) ES/E85(A) ES/E120(A) 3 to 9 3 to 18 3 to 36 3 to 36 6 to 54 6 to 54 6 to 54 12 20 30 40 50 85 120 6 to 54 10 6 Max 6 Max 6 Max 6 Max 12 Max 12 Max 12 Max 6 Max 6 Max 6 Max 6 Max 12 Max 12 Max 12 Max 12 Max 12 Max 6 10 20 30 30 40 50 6 10 20 30 40 50 65 80 120 Electric – Heavy Duty Products 12A-KW-3 20A-KW-3 30A-KW-3 40A-KW-3 M-II-50SF/CF M-II-80SF/CF M-II-120SF/CF(A) 3 to 9 3 to 18 3 to 36 3 to 36 6 to 54 6 to 54 6 to 54 NOTE: “SF” uses surface mounted thermostats. “CF” uses immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats. NOTE: (A) refers to ASME availability. Limited to “E” products. Typical Rheem-Ruud Configuration: E50-(kW)or ES50-(kW) If kW = 36; Example: E50-36 or ES50-36 Electric – Instantaneous/Booster Products L-I-6-3CF 6 to 58 Typical Bradford White Configuration: L-I-6-(kW)-3CF 5 E10 Example: L-I-6-36-3CF Electric – Light Duty and Point-of-Use Products LD-6U3-1CO15 LD-12U3-1C015 LD-20U3-1C015 LD-30U3-1C015 LD-30L3-3C045 LD-40L3-3CO45 LD-50L3-3C045 LD-WH6U3-1C015 LD-WH12U3-1C015 LD-WH20L3-1C015 LD-WH30L3-1C015 LD-40S3-3C045 LD-50S3-3CO45 LD-65R3-3C045 LD-80R3-3C045 LC-120R3-3C045 1.5 Max 1.5 Max 6 Max 6 Max 12 Max 12 Max 12 Max 1.5 Max 1.5 Max 6 Max 6 Max 12 Max 12 Max 12 Max 12 Max 12 Max 6 12 19 30 30 40 50 6 12 19 30 40 50 65 80 120 EGSP6 EGSP10 EGSP20 EGSP30 ELDS30 ELDS40 ELDS52 EGSP6 EGSP10 EGSP20 EGSP30 ELD40 ELD52 ELD66 ELD80 ELD120 61 62 LOCHINVAR TO RHEEM-RUUD CONVERSION CHART LOCHINVAR Model RHEEM-RUUD Btu/Hr. Gal Dia. Height Model CNR080-075 CNR090-100 CNR145-035-DF9 CNR125-075-DF9 CNR160-075-DF9 CNR180-080-DF9 CNR200-080-DF9 CNR200-100-DF9 CNR199-100-DF9 CNR250-100-DF9 CNR300-075-DF9 CNR370-065-DF9 CNR400-080-DF9 80,000 88,000 145,000 125,000 160,000 180,000 199,999 199,999 199,999 250,000 300,000 370,000 399,999 75 100 35 75 75 80 80 98 100 98 75 65 80 26" 28-1/4" 28-1/4' 28-1/4" 28-1/4" 28-1/4" 28-1/4" 28-1/4" 30-1/4" 28-1/4" 28-1/4" 28-1/4" 30-1/4" 63-3/4" 68-5/8" 50-5/8" 72-1/8" 72-1/8" 71-7/8" 71-7/8" 83" 74-1/4" 83" 74" 74" 77-1/4" G75-75 G100-75 G37-200 G75-125 G82-156 G76-180 G76-200 G91-200 G100-200 G100-250 G72-300 G65-360 G85-400 CNR500-080-DF9 CNR625-065-DF9 CNR725-080-DF9 505,000 625,000 725,000 80 65 80 28-1/4" 28" 28" 83" 68-7/8" 79-1/8" GX90-550(A) GX90-640(A) (2)-G65-360 250,000 300,000 370,000 399,999 505,000 625,000 725,000 98 75 65 80 80 65 80 28-1/4" 28-1/4" 28-1/4" 30-1/4" 28-1/4" 28" 28" 83" 74" 74" 77-1/4" 83" 68-7/8" 79-1/8" 199,999 100 28-1/4" 77-1/4" Btu/Hr. Gal Dia. Height 75 100 35 75 82 76 76 91 100 100 72 65 85 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 30-1/4" 30-1/4" 26-1/4" 26-1/4" 26-1/4" 64-3/8" 67-7/8" 49-1/4" 65-1/2" 68-13/16" 68-13/16" 68-13/16" 76-5/16" 73-1/16" 73-1/4" 71" 70-11/16" 78-13/16" 550,000 640,000 720,000 90 90 130 30" 30" ***** 74-1/2" 74-1/2" 70-11/16" G100-250(A) G72-300(A) G65-360(A) G85-400(A) GX90-550(A) GX90-640(A) GX90-715(A) 250,000 300,000 360,000 399,900 550,000 640,000 715,000 100 72 65 85 90 90 90 30-1/4" 26-1/4" 26-1/4" 26-1/4" 30" 30" 30" 73-1/4" 71" 70-11/16" 78-13/16" 74-1/2" 74-1/2" 74-1/2" GP100-200 199,900 100 30-1/4" 81-3/4" CNR Series 75,000 75,000 199,900 125,000 156,000 180,000 199,900 199,900 199,990 250,000 300,000 360,000 399,900 CNA (ASME) Series CNA251-100-DF9 CNA301-075-DF9 CNA371-065-DF9 CNA401-080-DF9 CNA501-080-DF9 CNA625-065-DF9 CNA725-080-DF9 PNR Series PNR200-100 63 64 LOCHINVAR TO RHEEM-RUUD CONVERSION CHART LOCHINVAR Model Btu/Hr. RHEEM-RUUD Gal Model Btu/Hr. Gal 180,000 199,000 85 85 G76-180 G76-200 180,000 199,900 76 76 90,000 135,000 180,000 199,000 225,000 270,000 315,000 360,000 399,000 500,000 ** ** ** ** ** ** ** ** ** ** GBB/GBBP-136 GBB/GBBP-136 GBC/GBCP-186 GBC/GBCP-186 GBC/GBCP-264 GBC/GBCP-264 GBC/GBCP-331 GBC/GBCP-399 GBC/GBCP-399 GBC/GBCP-512 136,000 136,000 181,000 181,000 264,000 264,000 334,000 399,000 399,000 511,500 ** ** ** ** ** ** ** ** ** ** 511,500 627,000 726,000 961,700 1,222,500 1,467,000 1,825,600 2,249,400 2,673,200 2,934,000 ** ** ** ** ** ** ** ** ** ** Gas – Hot Water Supply Heaters “Copper-Pak” Products CPN180-85 CPN199-85 “Better Idea” Products RWN090PM-F1 RWN135PM-F1 RWN180PM-F1 RWN199PM-F1 RWN225PM-F1 RWN270PM-F1 RWN315PM-F9 RWN360PM-F9 RWN399PM-F9 RWN500PM-F9 CWN495PM 495,000 ** GBC/GBCP-512 CWN645PM 645,000 ** GBC/GBCP-627 CWN745PM 745,000 ** GBC/GBCP-726 CWN985PM 985,000 ** GBC/GBCP-962 CWN1255PM 1,255,000 ** GBC/GBCP-1223 CWN1435PM 1,435,000 ** GBC/GBCP-1467 CWN1795PM 1,795,000 ** GBC/GBCP-1826 CWN2065PM 2,065,000 ** (2)-GBC/GBCP-1125 CWN2620PM 2,620,000 ** (2)-GBC/GBCP-1337 CWN3080PM 3,080,000 ** (2)-GBC/GBCP-1467 NOTE: ** Denotes less than 1 gallon storage capacity. NOTE: “PM” refers to pump mounted models. Also available without pumps. NOTE: “P” refers to pump mounted Rheem-Ruud models. Storage Tank Systems (**Unfired Storage Vessels) RJS080 ** 78 RJS085 ** 85 RJS120 ** 119 RJA120 ** 119 RJA200 ** 200 NOTE: See large volume storage tanks, page 40 and 41. ST80 ST80 ST120 ST120A ST200A ** ** ** ** ** 80 80 115 115 200 65 66 LOCHINVAR TO RHEEM-RUUD CONVERSION CHART LOCHINVAR Model kW RHEEM-RUUD Gal Model kW Gal Electric – Light Duty and Point-of-Use Products ETX/ETW030KK 12 Max 30 ELD30 12 Max ESX/ESW030KK 12 Max 30 ELDS30 12 Max ETX/ETW040KK 12 Max 40 ELD40 12 Max ESX/ESW040KK 12 Max 40 ELDS40 12 Max ETX/ETW052KK 12 Max 50 ELD52 12 Max ESX/ESW050KK 12 Max 50 ELDS52 12 Max ETX/ETW066KK 12 Max 65 ELD66 12 Max ETX/ETW082KK 12 Max 80 ELD80 12 Max ETX/ETW120KK 12 Max 120 ELD120 12 Max NOTE: “ETX/ESX” refers to 480 volt, 3 phase products. “ETW/ESW” refers to 277 volt, 1 phase products. NOTE: “ELD/ELDS” models are available in 208, 240, 277 or 480 volt (1 or 3 phase) configurations. 30 30 40 40 50 50 65 80 120 Electric – Heavy Duty Products HS*(kW)-052 HS*(kW)-082 HS*(kW)-120(A) HC*(kW)-052 HC*(kW)-082 HC*(kW)-120(A) 9 to 36 9 to 54 9 to 54 9 to 36 9 to 54 9 to 54 52 82 118 52 82 118 ES50 ES85 ES120 E50(A) E85(A) E120(A) 6 to 54 6 to 54 6 to 54 6 to 54 6 to 54 6 to 54 50 85 120 50 85 120 E10 6 to 54 10 Electric – Instantaneous/Booster Products SB*-(kW) 6 to 58 5 Note: * Refers to voltage/phase: A – 240 Volt, 1 Phase B – 240 Volt, 3 Phase J – 208 Volt, 1 Phase K – 208 Volt, 3 Phase P – 240 Volt, 1/3 Phase T – 208 Volt, 1/3 Phase W – 277 Volt, 1 Phase X – 480 Volt, 3 Phase R – Special - Must Specify 67 68 STATE TO RHEEM-RUUD CONVERSION CHART STATE RHEEM-RUUD Model Btu/Hr. Gas Water Heaters Gal Dia. Height Model Btu/Hr. Gal Dia. Height SBT75-75NE SBT100-75NE SBF75-120NE SBF75-140NE SBF30-150NE SBF80-180NE SBF30-199NE SBF80-199NE SBF100-199NES SBF100-199NET SBF30-199NE SBF30-225NE(A) SBF75-250NE(A) SBF100-260NES(A) SBF100-260NET(A) 75 100 75 75 30 80 30 80 100 100 30 30 75 100 100 26-1/4 28" 24" 24" 28" 28" 28" 28" 30-1/4" 28" 28" 28" 28" 30-1/4" 28" 67-1/2" 72" 76-3/4" 76-3/4" 49" 73-1/2" 49" 73-1/2" 71" 83" 49" 49" 75" 74" 84" G75-75 G100-75 G75-125 G82-156 G37-200 G76-180 G37-200 G76-200 G100-200 G91-200 G37-200 G37-200 G72-250(A) G100-270(A) G100-270(A) 75,000 75,000 125,000 156,000 199,900 180,000 199,900 199,900 199,900 199,900 199,900 199,900 250,000 270,000 270,000 75 100 75 82 35 76 35 76 100 91 35 35 72 100 100 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 30-1/4" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 30-1/4" 30-1/4" 64-3/8" 67-7/8" 65-1/2" 68-13/16" 49-1/4" 68-13/16" 49-1/4" 68-13/16" 73-1/16" 76-5/16" 49-1/4" 49-1/4" 71-1/16" 73-7/8" 73-7/8" SBF75-300NE(A) 300,000 75 28" SBF70-360NE(A) 360,000 70 28" SBF100-400NE(A) 399,900 100 30-1/4" SBF80-500NE(A) 500,000 80 30-1/4" SBF80-725NE(A) 725,000 80 30-1/4" SDV100-199NE 199,900 100 30-1/4" NOTE: (A) denotes ASME construction available. 75-1/2" 72-3/4" 77" 77-1/2" 75-1/2" 75" G72-300(A) G65-360(A) G100-400(A) GX90-550(A) GX90-715(A) GP100-200 300,000 360,000 399,900 550,000 715,000 199,900 72 65 100 90 90 100 26-1/4" 26-1//4" 30-1/4" 30" 30" 30-1/4" 71" 70-11/16" 76" 74-1/2" 74-1/2" 81-3/4" 75,100 75,100 120,000 140,000 150,000 180,000 199,900 199,900 199,900 199,900 199,900 225,000 250,000 260,000 260,000 Induced Draft Models SBN250(A) 250,000 SBN275(A) 275,000 SBN310(A) 310,000 SBN366(A) 366,000 100 100 85 85 27-3/4" 27-3/4" 27-3/4" 27-3/4" 72" 72" 73" 73" GD-100-250(A) GD-100-270(A) GD-100-310(A) GD-100-360(A) 250,000 270,000 310,000 360,000 100 100 100 100 30-1/4" 30-1/4" 30-1/4" 30-1/4" 73-1/2" 73-1/2" 73-1/2" 73-1/2" High Efficiency Models SUF-120 125,000 SUF-150 150,000 SUF-199 199,000 SUF-250(A) 240,000 SUF-300(A) 300,000 60 100 100 100 130 27-3/4" 27-3/4" 27-3/4" 27-3/4" 33" 55-1/2" 74-1/2" 74-1/2" 74-1/2" 74" HE80-130 GHE100-160 GHE100-200(A) GHE100-250(A) GHE100-300(A) 130,000 160,000 199,900 250,000 300,000 80 100 100 100 100 23-1/2" 26-1/4" 26-1/4" 26-1/4" 26-1/4" 72" 78-3/4" 78-3/4" 78-3/4" 78-3/4" 69 70 STATE TO RHEEM-RUUD CONVERSION CHART STATE Model kW RHEEM-RUUD Gal Model kW Gal 6 Max 6 Max 6 Max 6 Max 6 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 6 10 15 20 30 40 50 30 40 50 65 80 120 SB6-10 3 to 9 10 E12A 3 to 9 SB6-20 3 to 18 20 E20A 3 to 18 SB6-30 3 to 36 30 E30A 3 to 36 SB6-40 3 to 36 40 E40A 3 to 36 SB6-52-(kW)**(A) 6 to 81 52 ES50/E50(A) 6 to 54 SB6-82-(kW)**(A) 6 to 81 82 ES85/E85(A) 6 to 54 SB6-120-(kW)**(A) 6 to 81 119 ES120/E120(A) 6 to 54 NOTE: ** Refers to “SFE” which uses surface mounted thermostats. “IFE” uses immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats. 12 20 30 40 50 85 120 Electric – Point-of-Use and Light Duty Products CPE 6 10MSA CPE 10 10MSA CPE 17 10MSA CPE 20 10MSA CPE 30 10MSA CPE 40 20LSA CPE 50 20LSA CPE 30 20RTA CPE 40 20RTA CPE 52 20RTA CPE 66 20RTA CPE 82 20RTA CPE 120 20RTA 3.8 Max 6 Max 6 Max 6 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 12 Max 6 10 17 20 30 40 47 30 40 50 66 82 119 EGSP6 EGSP10 EGSP15 EGSP20 EGSP30 ELDS40 ELDS52 ELD30 ELD40 ELD50 ELD66 ELD80 ELD120 Electric – Heavy Duty Products Storage Tank Systems (**Unfired Storage Vessels) PV-82-0ORT(A) ** 82 PV-120-0ORT(A) ** 119 PV-200-0ORTA ** 200 NOTE: See large volume storage tanks, page 40 and 41. ST80(A) ST120(A) ST200A ** ** ** 80 115 200 71