Royal® Model Sensor Operated Flushometers ! Description Concealed, Sensor Operated Royal® Model Water Closet Flushometer, enclosed behind a 13” x 17” Wall Box with Stainless Steel Access Panel, for floor mounted back spud bowls with exposed back spud. ! Flush Cycle ! Model 140 WB ES-S Water Saver (3.5 gpf/13.2 Lpf) ! Model 140-1.6 WB ES-S Low Consumption (1.6 gpf/6.0 Lpf) ! Specifications Quiet, Concealed, Diaphragm Type, Rough Brass Closet Flushometer with the following features: • PERMEX™ Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass • OPTIMA® EL-1500-L Self-Adaptive Infrared Sensor with Indicator Light • User friendly three (3) second Flush Delay • Courtesy Flush™ Override Button • Non-Hold-Open Integral Solenoid Operator • 13” x 17” EASY ACCESS® Wall Box with Stainless Steel Access Panel and Vandal Resistant Screws • 1” I.P.S. Wheel Handle Bak-Chek™ Angle Stop • Adjustable Tailpiece • High Back Pressure Vacuum Breaker Flush Connection, Spud Coupling and Flanges for 1½” Exposed Back Spud • Sweat Solder Adapter • Chrome Plated Exposed Flushometer Parts • High Copper, Low Zinc Brass Castings for Dezincification Resistance • Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation • Flush Accuracy Controlled by CID™ Technology • Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX™ Rubber Compound for Chloramine Resistance Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance with the applicable sections of ASSE 1037, ANSI/ASME A112.19.6 and Military Specification V-29193. Installation conforms to ADA requirements. ! L Dimension Specify the “L” Dimension for the proper length of the Flush Connection. The “L” Dimension is equal to the Wall Thickness (to nearest whole inch) plus 2¾”. ! Variations ! TP Sloan OPTIMA® equipped Flushometers provide the ultimate in sanitary protection and automatic operation. There are no handles to trip or buttons to push. The Flushometer operates by means of an infrared sensor that adapts to its surrounding. Once the user enters the sensor’s effective range and then steps away, the Flushometer Solenoid initiates the flushing cycle to flush the fixture. Wall Box allows for vandal-proof concealed installation where pipe chase is not available or pipe space is limited. ! Hygienic Trap Primer Elbow ! Accessories 154 ! EL-1 342 ! EL-3 ! Automatic Transformer (120 VAC/24 VAC, 50 VA) Transformer (240 VAC/24 VAC, 50 VA) See Accessories Section and OPTIMA Accessories Section of the Sloan catalog for details on these and other OPTIMA Flushometer variations. This space for Architect/Engineer approval Job Name Date Model Specified Quantity Variations Specified Customer/Wholesaler User makes no physical contact with the Flushometer surface except to initiate the Override Button when required. Helps control the spread of infectious diseases. Twenty-four Hour Sentinel Flush keeps fixture fresh during periods of nonuse. ! Economical Automatic operation provides water usage savings over other flushing devices. Reduces maintenance and operation costs. ! Practical Solid state electronic circuitry assures years of dependable, trouble-free operation. The operational components of the Flushometer are identical to a handle operated Royal® Flushometer, proven by 90 years of experience. ! Warranty 3 year (limited) ! Made in the U.S.A. Contractor Architect The information contained in this document is subject to change without notice. Royal Optima 140 WB ES-S S.S. — Rev. 1 (01/02) WIRING DIAGRAM 120 VAC EL-1500-L SENSOR GND 24 VAC ! Description Concealed, Sensor Operated Royal® Model Water Closet Flushometer, enclosed behind a 13” x 17” Wall Box with Stainless Steel Access Panel, for floor mounted back spud bowls with exposed back spud. OVERRIDE BUTTON 24 VAC COIL COIL WIRE ! Flush Cycle ! Model 140 WB ES-S Water Saver (3.5 gpf/13.2 Lpf) ! Model 140-1.6 WB ES-S Low Consumption (1.6 gpf/6.0 Lpf) EL-1500-L SENSOR ELECTRICAL SPECIFICATIONS ! ! Control Circuit Solid State 24 VAC Input 24 VAC Output 8 Second Arming Delay 3 Second Flush Delay 24 Hour Sentinel Flush OPTIMA Sensor Range Nominal 22” - 42” (559 mm 1067 mm) Self-adaptive Window ± 10” (254 mm) UNIT #1 SOLENOID GROUND WIRE OVERRIDE BUTTON 24 VAC COIL ! Solenoid Operator ! Wall Box Specifications EASY ACCESS® Wall Box Assembly — Part #EL-192-A Frame: 13” x 17” x 4” (330 mm x 432 mm x 102 mm) #16 Gauge Steel Cover (Access Panel): 14½” x 18½” (368 mm x 470 mm) #15 Gauge #304 Stainless Steel, #4 Finish Screws: (6) #8-32 x ¾” Drilled Spanner Head — Spanner Bit Provided UNIT #2 THRU #10 (IF USED) COIL WIRE 24 VAC, 50/60 Hz SOLENOID GROUND WIRE ! Transformer Sloan Part #EL-154 120 VAC, 50/60 Hz Primary 24 VAC, 50/60 Hz Secondary Class II, UL Listed, 50 VA. Sloan Part #EL-342 240 VAC, 50/60 Hz Primary 24 VAC, 50/60 Hz Secondary Class II, UL Listed, 50 VA. One Transformer serves up to ten (10) OPTIMA Closet/Urinal Flushometers. Specify number of transformers required accordingly. OPERATION 1. A continuous, invisible light beam is emitted from the OPTIMA Sensor. 2. As the user enters the beam’s effective range (22” to 42”) the beam is reflected into the OPTIMA Scanner Window and transformed into a low voltage electrical circuit. Once activated, the Output Circuit continues in a “hold” mode for as long as the user remains within the effective range of the Sensor. 3. When the user steps away from the OPTIMA Sensor, the circuit waits 3 seconds (to prevent false flushing) then initiates an electrical “onetime” signal that operates the Solenoid. This initiates the flushing cycle to flush the fixture. The Circuit then automatically resets and is ready for the next user. ELECTRICAL BOX INSTALLATION SENSOR LOCATION AND POSITIONING IS CRITICAL Failure to properly position the electrical boxes to the plumbing rough-in will result in improper installation and impair product performance. All tradesmen (plumbers, electricians, tile setters, etc.) involved with the installation of this product must coordinate their work to assure proper product installation. TOP OF WALL BOX MOUNTING BRACKET (EL-195) OVERRIDE BUTTON EL-1500-L SENSOR LOCATION Adjust the Mounting Bracket so that the Sensor sits flush against the Cover Plate. † Refer to the instructions packaged with the Flushometer for additional installation information. Required Wall Opening SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • http://www.sloanvalve.com Copyright © 2002 Sloan Valve Company Printed in the U.S.A. Made in the U.S.A. Royal Optima 140 WB ES-S S.S. — Rev. 1 (01/02)