Royal Optima 140 WB ES

advertisement
Royal®
Model
Sensor Operated Flushometers
! Description
Concealed, Sensor Operated Royal® Model Water Closet Flushometer,
enclosed behind a 13” x 17” Wall Box with Stainless Steel Access Panel, for
floor mounted back spud bowls with exposed back spud.
! Flush Cycle
! Model 140 WB ES-S Water Saver (3.5 gpf/13.2 Lpf)
! Model 140-1.6 WB ES-S Low Consumption (1.6 gpf/6.0 Lpf)
! Specifications
Quiet, Concealed, Diaphragm Type, Rough Brass Closet Flushometer with the
following features:
• PERMEX™ Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass
• OPTIMA® EL-1500-L Self-Adaptive Infrared Sensor with Indicator Light
• User friendly three (3) second Flush Delay
• Courtesy Flush™ Override Button
• Non-Hold-Open Integral Solenoid Operator
• 13” x 17” EASY ACCESS® Wall Box with Stainless Steel Access Panel and
Vandal Resistant Screws
• 1” I.P.S. Wheel Handle Bak-Chek™ Angle Stop
• Adjustable Tailpiece
• High Back Pressure Vacuum Breaker Flush Connection, Spud Coupling and
Flanges for 1½” Exposed Back Spud
• Sweat Solder Adapter
• Chrome Plated Exposed Flushometer Parts
• High Copper, Low Zinc Brass Castings for Dezincification Resistance
• Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass and No
External Volume Adjustment to Ensure Water Conservation
• Flush Accuracy Controlled by CID™ Technology
• Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX™
Rubber Compound for Chloramine Resistance
Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with
ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance with
the applicable sections of ASSE 1037, ANSI/ASME A112.19.6 and Military
Specification V-29193. Installation conforms to ADA requirements.
! L Dimension
Specify the “L” Dimension for the proper length of the Flush Connection. The
“L” Dimension is equal to the Wall Thickness (to nearest whole inch) plus 2¾”.
! Variations
! TP
Sloan OPTIMA® equipped Flushometers provide the
ultimate in sanitary protection and automatic operation.
There are no handles to trip or buttons to push. The
Flushometer operates by means of an infrared sensor that
adapts to its surrounding. Once the user enters the
sensor’s effective range and then steps away, the
Flushometer Solenoid initiates the flushing cycle to flush
the fixture. Wall Box allows for vandal-proof concealed
installation where pipe chase is not available or pipe space
is limited.
! Hygienic
Trap Primer Elbow
! Accessories
154
! EL-1
342
! EL-3
! Automatic
Transformer (120 VAC/24 VAC, 50 VA)
Transformer (240 VAC/24 VAC, 50 VA)
See Accessories Section and OPTIMA Accessories Section of the Sloan catalog
for details on these and other OPTIMA Flushometer variations.
This space for Architect/Engineer approval
Job Name
Date
Model Specified
Quantity
Variations Specified
Customer/Wholesaler
User makes no physical contact with the Flushometer
surface except to initiate the Override Button when
required. Helps control the spread of infectious diseases.
Twenty-four Hour Sentinel Flush keeps fixture fresh during
periods of nonuse.
! Economical
Automatic operation provides water usage savings over
other flushing devices. Reduces maintenance and
operation costs.
! Practical
Solid state electronic circuitry assures years of
dependable, trouble-free operation. The operational
components of the Flushometer are identical to a handle
operated Royal® Flushometer, proven by 90 years of
experience.
! Warranty
3 year (limited)
! Made in the U.S.A.
Contractor
Architect
The information contained in this document is subject to change without notice.
Royal Optima 140 WB ES-S S.S. — Rev. 1 (01/02)
WIRING
DIAGRAM
120 VAC
EL-1500-L SENSOR
GND
24 VAC
! Description
Concealed, Sensor Operated Royal® Model Water Closet Flushometer,
enclosed behind a 13” x 17” Wall Box with Stainless Steel Access
Panel, for floor mounted back spud bowls with exposed back spud.
OVERRIDE BUTTON
24 VAC COIL
COIL WIRE
! Flush Cycle
! Model 140 WB ES-S Water Saver (3.5 gpf/13.2 Lpf)
! Model 140-1.6 WB ES-S Low Consumption (1.6 gpf/6.0 Lpf)
EL-1500-L SENSOR
ELECTRICAL SPECIFICATIONS
!
!
Control Circuit
Solid State
24 VAC Input
24 VAC Output
8 Second Arming Delay
3 Second Flush Delay
24 Hour Sentinel Flush
OPTIMA Sensor Range
Nominal 22” - 42” (559 mm 1067 mm)
Self-adaptive Window ± 10”
(254 mm)
UNIT #1
SOLENOID
GROUND
WIRE
OVERRIDE BUTTON
24 VAC COIL
! Solenoid Operator
! Wall Box Specifications
EASY ACCESS® Wall Box
Assembly — Part #EL-192-A
Frame: 13” x 17” x 4” (330 mm
x 432 mm x 102 mm) #16
Gauge Steel
Cover (Access Panel): 14½” x
18½” (368 mm x 470 mm) #15
Gauge #304 Stainless Steel,
#4 Finish
Screws: (6) #8-32 x ¾” Drilled
Spanner Head — Spanner Bit
Provided
UNIT #2
THRU #10
(IF USED)
COIL WIRE
24 VAC, 50/60 Hz
SOLENOID
GROUND
WIRE
! Transformer
Sloan Part #EL-154
120 VAC, 50/60 Hz Primary
24 VAC, 50/60 Hz Secondary
Class II, UL Listed, 50 VA.
Sloan Part #EL-342
240 VAC, 50/60 Hz Primary
24 VAC, 50/60 Hz Secondary
Class II, UL Listed, 50 VA.
One Transformer serves
up to ten (10) OPTIMA
Closet/Urinal
Flushometers. Specify
number of transformers
required accordingly.
OPERATION
1. A continuous, invisible light
beam is emitted from the
OPTIMA Sensor.
2. As the user enters the beam’s
effective range (22” to 42”)
the beam is reflected into the
OPTIMA Scanner Window
and transformed into a low
voltage electrical circuit.
Once activated, the Output
Circuit continues in a “hold”
mode for as long as the user
remains within the effective
range of the Sensor.
3. When the user steps away
from the OPTIMA Sensor, the
circuit waits 3 seconds (to
prevent false flushing) then
initiates an electrical “onetime” signal that operates the
Solenoid. This initiates the
flushing cycle to flush the
fixture. The Circuit then
automatically resets and is
ready for the next user.
ELECTRICAL BOX INSTALLATION
SENSOR LOCATION AND POSITIONING IS CRITICAL
Failure to properly position the electrical boxes to the plumbing rough-in
will result in improper installation and impair product performance. All
tradesmen (plumbers, electricians, tile setters, etc.) involved with the
installation of this product must coordinate their work to assure proper
product installation.
TOP OF WALL BOX
MOUNTING
BRACKET
(EL-195)
OVERRIDE BUTTON
EL-1500-L SENSOR
LOCATION
Adjust the Mounting Bracket so that the Sensor sits flush against the Cover Plate.
†
Refer to the instructions packaged with the Flushometer for additional installation
information.
Required Wall Opening
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • http://www.sloanvalve.com
Copyright © 2002 Sloan Valve Company
Printed in the U.S.A.
Made in the U.S.A.
Royal Optima 140 WB ES-S S.S. — Rev. 1 (01/02)